AV Construction Drawings.pdf
PDF 2 MB Posted
- Attached to
- Board Room Audiovisual Systems Modernization
- Solicitation number
- 148111
- Issued by
- Howard County, Maryland
About this file
This is an audiovisual construction drawings document prepared by Cerami & Associates for the Columbia Association Boardroom Improvement Project in Maryland. The project encompasses the design and installation of comprehensive audiovisual systems including building-wide digital signage, wayfinding kiosks, video conferencing and collaboration endpoints, audio signal processing systems, control systems programming, and related infrastructure. The scope includes furniture elements such as lecterns, conference tables, millwork, and credenzas, as well as the testing, installation, and commissioning of audiovisual equipment. The document establishes a detailed responsibility matrix delineating tasks among the owner (Cerami), audiovisual contractor, general contractor, electrical contractor, furniture contractor, millwork contractor, architect, and IT consultant, with specific assignments for infrastructure, cabling, equipment procurement, installation, and programming phases of the project.
The construction drawings package includes 100 percent design documents with eleven sheets covering audiovisual cover sheets, general notes, floor plans, reflected ceiling plans, enlarged detailed views for the boardroom, rack room, and production studio, equipment details, and system flow diagrams. The document specifies minimum cable performance requirements with approved manufacturer options including Belden, CommScope, West Penn, Liberty Cable, and others, subject to submission and approval of technical data sheets prior to installation. All audiovisual cabling outside of metal conduit must be plenum-rated, and the contractor is required to use plugs and jacks specifically manufactured for the respective cables. The drawings include comprehensive specifications for audio cabling (microphone, line level, digital, and speaker level applications), video cabling (UTP and coaxial), and RF/CATV components, with detailed abbreviations and legends provided for construction clarity and reference.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 27-18 Board Room AV Systems Modernization.pdf | ||
| Reference Form.docx | DOCX document | |
| Minority Business Enterprise (MBE) Participation Form.docx | DOCX document | |
| BID PRICE BREAKDOWN.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Building-Wide Systems Lobby/Public Area Wayfinding Kiosks Room Booking Displays Digitial Signage Endpoints
Video Conferencing / Collaboration
Back end content and management servers including trunking and firewall traversal hardware
Video conference endpoints
Software video conference clients Furniture Lecterns and teachers stations Millwork countertops, credenzas, conference tables and general woodwork.
Conference table connectivity hatch
Testing and evaluation existing equipment intended for reuse
Installation of existing equipment intended for reuse
Control system(s) programming Audio Signal Processing and Misc Systems Programming Contractor Project management, supervision, testing and commissioning of the AV systems Audiovisual Systems Punch List
Cerami
Cerami
Cerami
Commissioning, Programming and Project Management
Owner
Cerami
Cerami
Cerami
Cerami
Owner
Cerami
Cerami
Cerami
Cerami
Audiovisual
Audiovisual
Audiovisual
Audiovisual
Audiovisual
Owner
Owner
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Cerami
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Architect
Architect
Architect/Cerami
Furniture
Millwork
Furniture
Furniture Contractor
Millwork Contractor
Furniture Contractor
Furniture Contractor
Millwork Contractor
Furniture Contractor
Owner
Cerami
Owner
Owner
Cerami
Owner
Owner
Audiovisual
Owner
Owner Owner
Owner/Audiovisual Contractor Audiovisual Contractor
Owner Owner
Cerami Cerami Cerami
Cerami Cerami Cerami
Audiovisual Audiovisual Audiovisual
Audiovisual Contractor Audiovisual Contractor Audiovisual Contractor
Audiovisual Contractor Audiovisual Contractor Audiovisual Contractor
Item Infrastructure
Containment, conduit, junction boxes, wireways and other electrical (construction related) rough-in work pertaining to the installation of the AV systems.
Floor boxes or poke-thru with shared access for audiovisual, tele/data and power systems In-wall boxes with shared access for audiovisual, tele/data and power systems All Audiovisual cable tray All fire rated penetrations All AC power receptacles and related electrical requirements
IT, tele/data infrastructure as required for AV systems
All low voltage audiovisual cabling All low voltage audiovisual terminations
Equipment Wall blocking, uni-strut/kindorf, threaded rod, etc as required for AV devices Handling of all AV equipment from building dock to a secure location Program speakers Ceiling speakers/microphones (with back boxes, transformers & grilles where applicable) Ceiling and wall mounted lcd or flat panel displays and cameras Ceiling mounted video projectors and lifts
Control system touch screens and other hardware.
Provision of all OFE pc's and servers (as required)
Cerami
Cerami
Cerami
Cerami
Cerami
Cerami
Cerami
Cerami
Architect / MEP
Cerami
Cerami
Cerami
Cerami
Cerami
Cerami
Cerami
General Contractor
Audiovisual
Audiovisual
Audiovisual
Audiovisual
Audiovisual
Audiovisual
Audiovisual
General Contractor
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Owner
General Contractor
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Audiovisual Contractor
Cerami
Cerami
Cerami
Cerami Cerami
Cerami
Cerami
Cerami Cerami
Cerami / MEP
MEP
MEP
MEP
MEP
MEP
Cerami
Cerami Cerami
Electrical
Electrical
Electrical
Electrical Electrical
Electrical
IT Consultant
Audiovisual Audiovisual
Electrical Contractor
Electrical Contractor
Electrical Contractor
Electrical Contractor Electrical Contractor
Electrical Contractor
Low Voltage Contractor
Audiovisual Contractor Audiovisual Contractor
Electrical Contractor
Electrical Contractor
Electrical Contractor
Electrical Contractor Electrical Contractor
Electrical Contractor
Low Voltage Contractor
Audiovisual Contractor Audiovisual Contractor
Requirements Provided by
Audiovisual Systems Scope of Responsibility Matrix
Documented by Package Furnished by Installed by
AFC
AFF
AHJ
ABBREVIATIONS
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
AUTHORITY HAVING JURISDICTION
A AMPERAGE, AMPERE
AMP AMPLIFIER
ANT ANTENNA
AUD AUDIO
AUX AUXILIARY
AV AUDIO VIDEO
AV SVR AUDIO VIDEO SERVER
CATV CABLE TELEVISION
CAM CAMERA
CG COMMON GROUND
CL CENTERLINE
CTRL CONTROL, CONTROLLER
CTL CONTROL, CONTROLLER
CURT CURTAIN
DMARC DEMARCATION POINT
DLP DIGITAL LIGHT PROCESSING
DN DOWN
DSP DIGITAL SIGNAL PROCESSOR/ING
DX DUPLEX
EC ELECTRICAL CONTRACTOR,
ELECTRICAL CONDUIT
EMER EMERGENCY
FIB FIBER OPTIC
FA FIRE ALARM
FM FM RADIO FREQUENCY
FW FIRE WIRE
GC GENERAL CONTRACTOR
GEN GENERATOR
GFCI GROUND FAULT CIRCUIT
INTERRUPTER
GND GROUND
HD HIGH DEFINITION
HDMI HIGH DEFINITION MULTIMEDIA
INTERFACE
IR INFRARED
I/O INPUT/OUTPUT
IG ISOLATED GROUND
IP INTERNET PROTOCOL
IWB IN WALL BOX
JB, JBOX JUNCTION BOX
K KEY, KEYED, KEY OPERATED
KVM KEYBOARD/VIDEO/MOUSE
L LEFT
LAN LOCAL AREA NETWORK
LCD LIQUID CRYSTAL DISPLAY
LED LIGHT EMITTING DIODE
M MOTOR, MOTORIZED
MIC MICROPHONE
MTX MATRIX
NTS NOT TO SCALE
OCC OCCUPIED. OCCUPANCY
POE POWER OVER ETHERNET
PTZ PAN / TILT / ZOOM
PNL PANEL
QUAD QUADRAPLEX
R RIGHT
RK RACK
RF RADIO FREQUENCY
RX RECEIVE. RECEIVER
SAT SATELLITE
SCRN SCREEN
SDI SERIAL DIGITAL INTERFACE
SPKR SPEAKER, LOUDSPEAKER
SVR CPU / SERVER
SW SUBWOOFER
TEL TELEPHONE
TEMP TEMPERATURE, TEMPORARY
TP TOUCH PANEL
TPD TOUCH PANEL DOCK
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER
SUPPLY
V VOLT, VOLTAGE
VOIP VOICE OVER IP
VOL VOLUME
WB WALL BOX
WP WEATHERPROOF
WIFI WIRELESS LOCAL AREA
NETWORK
ACOUSTICS ● AUDIOVISUAL● IT ● SECURITY
1001 SIXTH AVENUE, 4TH FLOOR
NEW YORK, NY 10018
T 212 370 1776
WWW.CERAMIASSOCIATES.COM
THIS DOCUMENT AND THE IDEAS INCORPORATED HEREIN, AS AN
INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF CERAMI &
ASSOCIATES INC. AND IS NOT TO BE USED IN WHOLE OR IN PART, FOR ANY
OTHER PROJECT OR PURPOSE WITHOUT THE WRITTEN AUTHORIZATION
OF CERAMI & ASSOCIATES, INC.
© COPYRIGHT 2024 CERAMI & ASSOCIATES, INC. ALL RIGHTS RESERVED
PROJECT #: SCALE: DATE:
DRAWN BY: CHECKED BY:ENG. BY:
PROJECT NAME:
TITLE:
NOTES:
SHEET #:
CLIENT:
12" = 1'-0"
COLUMBIA
ASSOCIATION
BOARDROOM
IMPROVEMENT
PROJECT
AUDIOVISUAL COVER
SHEET
262110.0001 01/18/14
TA-000
AUDIOVISUAL DRAWING LIST
# SHEET TITLE 10
0%
C
ON
ST
RU
CT
IO
N
DR
AW
IN
GS
7/1 3/2
AUDIOVISUAL
000 - DRAWING INDEX / LEGENDS
TA-000 AUDIOVISUAL COVER SHEET X
TA-001 AUDIOVISUAL GENERAL NOTES X
200 - OVERALL FLOOR PLANS
TA-201 AUDIOVISUAL OVERALL FLOOR PLAN X
300 - OVERALL REFLECTED CEILING PLANS
TA-301 AUDIOVISUAL OVERALL RCP X
600 - ENLARGED PLANS
TA-601 AUDIOVISUAL ENLARGED VIEWS - BOARDROOM X
TA-602 AUDIOVISUAL ENLARGED VIEWS - RACK ROOM X
TA-603 AUDIOVISUAL ENLARGED VIEWS - PRODUCTION STUDIO X
700 - EQUIPMENT DETAILS
TA-701 AUDIOVISUAL DETAILS X
800 - SYSTEM FLOW DIAGRAMS
TA-801 AUDIOVISUAL SYSTEM FLOW DIAGRAMS - BOARDROOM X
TA-802 AUDIOVISUAL SYSTEM FLOW DIAGRAMS - PRODUCTION
STUDIO & RACK
X
REV. DATE DESCRIPTION
1 7/13/26 100% CD
CABLE TYPES SCHEDULE
1.
2.
3.
THESE CABLE TYPES ARE CITED TO ILLUSTRATE THE MINIMUM CABLE PERFORMANCE REQUIREMENTS. UNLESS OTHERWISE NOTED, CABLES FROM OTHER MANUFACTURERS (E.G. WEST PENN, COMM SCOPE, LIBERTY CABLE, ETC.) WILL BE CONSIDERED IF DATA SHEETS ARE SUBMITTED PRIOR TO INSTALLATION AND APPROVED BY AV CONSULTANT.
THE USE OF PLENUM RATED CABLING IS REQUIRED FOR ALL AV CABLING RUN OUTSIDE OF METAL CONDUIT.
THE CONTRACTOR SHALL ONLY USE PLUGS AND JACKS SPECIFICALLY MANUFACTURED AND DESIGNED FOR THE CABLE USED.
CABLE TYPE DESCRIPTION MANUFACTURER
NON-PLENUM
MODEL
PLENUM
MODEL
AUDIO
AUDIO (MICROPHONE & LINE LEVEL) (1) PAIR 22 AWG TWISTED PAIR BELDEN 9451 9451P
AUDIO (DIGITAL) (1) PAIR 24 AWG (110 OHM) TWISTED PAIR 1800F 1801B
AUDIO (SPEAKER LEVEL, 70V) 2 CONDUCTOR 18 AWG STRANDED 5300UP 82740
AUDIO (SPEAKER LEVEL, SPEECH) 2 CONDUCTOR 16 AWG STRANDED 5200UP 6200UE
AUDIO (SPEAKER LEVEL, PROGRAM) 2 CONDUCTOR 14 AWG STRANDED 5100UP 6100UE
AUDIO (SPEAKER LEVEL, PERFORMANCE) 2 CONDUCTOR 12 AWG STRANDED 5000UP 6000UE
AUDIO (SPEAKER LEVEL, HIGH WATTAGE) 2 CONDUCTOR 10 AWG STRANDED 5T00UP 6T00UP
VIDEO
VIDEO (UTP NON-CATEGORY) (4) PAIR 24 AWG LOW-SKEW TWISTED PAIR BELDEN 7987R 7987P
VIDEO (UTP CATEGORY) REFER TO IT PROJECT STANDARDS
VIDEO (ANALOG COMPONENT VIDEO) RG-59/U 20 AWG 75 OHM COAX BELDEN 8281 88281
VIDEO (DIGITAL VIDEO) RG-59/U 20 AWG 75 OHM COAX BELDEN 1505A 1506A
RF / CATV / ALS / WIRELESS ANT COAX
RF (HARDLINE) HARDLINE (75 OHM) COMMSCOPE P3-500 SERIES JCAR
RF (COAX <150') RG-6/U (75 OHM) BELDEN 9118 1152A
RF (COAX <250') RG-11/U (75 OHM) BELDEN 9064 1153A
RF (COAX TRIAX') RG-11/U (75 OHM) BELDEN 1858A 1859A
RF (WIRELESS ANTENNA) RG-8/U (50 OHM) BELDEN 9913F7 89913
RF (MICROWAVE ANTENNA; RISER-RATED) HELIAX (50 OHM) ANDREW LDF4-50A -
AV/UTP CATEGORY & CONTROL
CRESNET CONTROL CABLE CRESTRON CRESNET-NP CRESNET-P
DIGITAL MEDIA 8G ULTRA CABLE 4K CAT 7A 4-PAIR 22 AWG SOLID BARE COPPER CRESTRON DM-CBL-ULTRA-NP DM-CBL-ULTRA-P
DIGITAL MEDIA 8G CABLE
FIBER
OM3 MM (##) 50uM OM3 MULTI-MODE (FIBER STRAND COUNT
PER DRAWINGS)
CORNING - 0##T81-31180-29
OM4 MM CORNING - 0##T81-31190-29
OS2 SM CORNING - 0##T81-31131-29
NOTE: CONTRACTOR TO PROVIDE ARMORED
EQUIVALENTS AS INDICATED IN THE DRAWING
PACKAGE
SMPTE 304M CAMERA (4) 20AWG COPPER, (2) 24AWG COPPER,
(2) SINGLE-MODE FIBER MOHAWK 96040 96920
BELDEN
BELDEN
BELDEN
BELDEN
BELDEN
BELDEN
(##) 50uM OM4 MULTI-MODE (FIBER STRAND COUNT
PER DRAWINGS)
(##) SINGLE-MODE (FIBER STRAND COUNT PER
DRAWINGS)
0##T81-31180-24
0##T81-31190-24
0##T81-31131-24
SHIELDED TWISTED PAIR CABLE
CONTROL (SERIAL APPLICATIONS)
CONTROL (TOUCH/CONTROL SYSTEM APPLICATIONS)
CONTROL (NETWORK)
(4) PAIR SHIELDED 24 AWG TWISTED PAIR SOLID
BARE COPPER
EXTRON 22-236-03 22-235-03
(2) PAIR 22 AWG TWISTED PAIR BELDEN 8723 88723
(1) PAIR 22 AWG TWISTED PAIR &
(1) PAIR 18 AWG
BELDEN 1502R 1502P
REFER TO IT PROJECT STANDARDS
CRESTRON DM-CBL-8G-NP DM-CBL-8G-P
(1) PAIR 22 AWG TWISTED PAIR & (1) PAIR 18 AWG
CAT 5E 4-PAIR 22 AWG SOLID COPPER
2018-12-30
RS RS
ROOM SCHEDULER
SOLID WALL MOUNTING
ROOM SCHEDULER
GLASS WALL MOUNTING
PATCH CABLE RUN
THROUGH GLASS FRONT
MULLION TO BE PROVIDED
BY CONTRACTOR. 3/4"
MINIMUM HOLE WITH FINISH
GROMMET IN MULLION TO BE
PROVIDED BY GLASS FRONT
CONTRACTOR AND
COORDINATED WITH AV
CONTRACTOR PRIOR TO
FABRICATION
ACCESSIBLE
CEILING
FLOOR
(1 ) 1
" E C
ACCESSIBLE
CEILING
FLOOR
DATA DROP, IN IT SCOPE
MOUNTING METHOD TO
GLASS OR MULLION BASED
ON APPROVED GLASS
SYSTEM
4X4 BOX WITH 2-
GANG MUD RING44
6"
WALL MTD CONTROL PANEL
FLOOR
MA
X.
4'
- 0
CP
IR
IR EMITTER/RECEIVER
CEILING
FLOOR
MI
N.
7'
- 0
C. DATA CONNECTION: DEDICATED TO AV DEVICE.
REFER TO TELECOM DRAWINGS FOR DETAILS AND
CONDUIT REQUIREMENTS.
A. ELECTRICAL CONNECTION: DEDICATED TO AV DEVICE.
REFER TO ELECTRICAL DRAWINGS FOR PLACEMENT,
CIRCUITING, AND CONDUIT REQUIREMENTS
a
B. AUDIOVISUAL CONNECTIVITY: SPECIFIED JUNCTION
BOX DEDICATED TO AV CONNECTIVITY. AV
DEVICE KEY INDICATES JUNCTION BOX SIZE. REFER
TO SYSTEM FLOW DIAGRAMS AND EQUIPMENT LIST
FOR INTERFACE (CONNECTION) TYPE.
b b a.
b.
ALIGN CENTERLINES OF POWER, DATA, AND AV
CONNECTIONS - REFER TO ELEVATIONS FOR HEIGHT.
LOCATE POWER, DATA, AND AV CONNECTIONS WITH
EQUAL SPACING BETWEEN COVERPLATES.
B. AUDIOVISUAL CONNECTIVITY
C. DATA CONNECTION
A. POWER CONNECTION
NOTE: FOR IN-WALL BOXES (PAC BOXES AND SIMILAR)
REFER TO DETAIL FOR LOCATION OF POWER AND
DATA CONNECTIONS WITHIN THE IN-WALL BOX
DEDICATED CONDUIT(S) FOR AV CONNECTIVITY,
EXTEND TO ACCESSIBLE LOCATION ABOVE
CEILING, PROVIDE CONDUIT BUSHING RING AT
THE OPEN END. REFER TO CONDUIT RISER
DIAGRAMS FOR QUANTITY AND SIZES.
ACOUSTICS ● AUDIOVISUAL● IT ● SECURITY
1001 SIXTH AVENUE, 4TH FLOOR
NEW YORK, NY 10018
T 212 370 1776
WWW.CERAMIASSOCIATES.COM
THIS DOCUMENT AND THE IDEAS INCORPORATED HEREIN, AS AN
INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF CERAMI &
ASSOCIATES INC. AND IS NOT TO BE USED IN WHOLE OR IN PART, FOR ANY
OTHER PROJECT OR PURPOSE WITHOUT THE WRITTEN AUTHORIZATION
OF CERAMI & ASSOCIATES, INC.
© COPYRIGHT 2024 CERAMI & ASSOCIATES, INC. ALL RIGHTS RESERVED
PROJECT #: SCALE: DATE:
DRAWN BY: CHECKED BY:ENG. BY:
PROJECT NAME:
TITLE:
NOTES:
SHEET #:
CLIENT:
As indicated
COLUMBIA
ASSOCIATION
BOARDROOM
IMPROVEMENT
PROJECT
AUDIOVISUAL GENERAL
NOTES
262110.0001 04/14/14
TA-001
1 AUDIOVISUAL MOUNTING STANDARDS
2 AUDIOVISUAL CONNECTIVITY (TYPICAL)
BOARDROOM
RACK ROOM
TA-601
TA-602
TA-603
PRODUCTION
STUDIO ARCHIVE ROOM
ACOUSTICS ● AUDIOVISUAL● IT ● SECURITY
1001 SIXTH AVENUE, 4TH FLOOR
NEW YORK, NY 10018
T 212 370 1776
WWW.CERAMIASSOCIATES.COM
THIS DOCUMENT AND THE IDEAS INCORPORATED HEREIN, AS AN
INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF CERAMI &
ASSOCIATES INC. AND IS NOT TO BE USED IN WHOLE OR IN PART, FOR ANY
OTHER PROJECT OR PURPOSE WITHOUT THE WRITTEN AUTHORIZATION
OF CERAMI & ASSOCIATES, INC.
© COPYRIGHT 2024 CERAMI & ASSOCIATES, INC. ALL RIGHTS RESERVED
PROJECT #: SCALE: DATE:
DRAWN BY: CHECKED BY:ENG. BY:
PROJECT NAME:
TITLE:
NOTES:
SHEET #:
CLIENT:
1/4" = 1'-0"
COLUMBIA
ASSOCIATION
BOARDROOM
IMPROVEMENT
PROJECT
AUDIOVISUAL OVERALL
FLOOR PLAN
262110.0001 01/19/14
TA-201
REV. DATE DESCRIPTION
1/4" = 1'-0"1 FLOOR PLAN
BOARDROOM
RACK ROOM
TA-601
PRODUCTION
STUDIO ARCHIVE ROOM
ACOUSTICS ● AUDIOVISUAL● IT ● SECURITY
1001 SIXTH AVENUE, 4TH FLOOR
NEW YORK, NY 10018
T 212 370 1776
WWW.CERAMIASSOCIATES.COM
THIS DOCUMENT AND THE IDEAS INCORPORATED HEREIN, AS AN
INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF CERAMI &
ASSOCIATES INC. AND IS NOT TO BE USED IN WHOLE OR IN PART, FOR ANY
OTHER PROJECT OR PURPOSE WITHOUT THE WRITTEN AUTHORIZATION
OF CERAMI & ASSOCIATES, INC.
© COPYRIGHT 2024 CERAMI & ASSOCIATES, INC. ALL RIGHTS RESERVED
PROJECT #: SCALE: DATE:
DRAWN BY: CHECKED BY:ENG. BY:
PROJECT NAME:
TITLE:
NOTES:
SHEET #:
CLIENT:
1/4" = 1'-0"
COLUMBIA
ASSOCIATION
BOARDROOM
IMPROVEMENT
PROJECT
AUDIOVISUAL OVERALL
RCP
262110.0001 01/19/14
TA-301
REV. DATE DESCRIPTION
1/4" = 1'-0"1 REFLECTED CEILING PLAN
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
NOTE:
DEVICE MOUNTING COORDINATION WITH ARCHITECTURE MILLWORK
REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR COORDINATED AV
INFRASTRUCTURE AND ELECTRICAL DEVICE LOCATIONS.
DISPLAYS ARE TO BE MOUNTED CENTERED ON THE CENTERLINE OF THE TABLE WHICH MAY
NOT BE THE CENTERLINE OF THE MOUNTING WALL.
STUD PLACEMENT TO BE COORDINATED WITH DISPLAY IN-WALL BOX MOUNTING TO KEEP
IN-WALL BOX ALONG THE CENTERLINE OF THE DISPLAY.
WHERE THE DISPLAYS ARE MOUNTED BACK-TO-BACK ON A COMMON PARTITION, THE
DISPLAY IN-WALL BOXES ARE TO BE OFFSET AROUND A CENTER STUD.
DISPLAY WIDTH AND HEIGHTS SHOWN ARE REPRESENTATIVE AND ARE TO BE CONFIRMED
WITH THE FINAL CONTRACTOR PROVIDED CUT-SHEETS PRIOR TO ROUGHING AND DISPLAY
RECESSES OR COORDINATING OTHER CRITICAL CLEARANCES.
WHEN RECESSED, PROVIDE A 2" MINIMUM CLEARANCE AROUND TOP, BOTTOM AND SIDES
OF DISPLAY.
ALL TOUCH PANEL BACKBOXES MOUNTED ON THE SAME WALL AS DISPLAYS ARE TO BE
HELD 12" CLEAR BETWEEN THE EDGE OF THE DISPLAY AND THE CENTERLINE OF THE
TOUCH PANEL BACKBOX.
ROOM SCHEDULING DISPLAY CABLING PENETRATIONS IN THE FLOOR/CEILING ARE TO BE
COORDINATED WITH EITHER SOLID PARTITION CENTERLINES OR, WHEN MOUNTED ON
GLASS, WITH THE CENTERLINE OF THE DOOR EXTRUSION TO ALLOW A NETWORK PATCH
CABLE TO BE RUN WITHIN THE EXTRUSION.
ALL CONTROL AND SCHEDULING DEVICE HEIGHTS TO BE COORDINATED WITH
ARCHITECTURAL ELEVATIONS AND MUST ALLOW THE TOP OF THE DEVICE TO BE UNDER 48"
PER ADA.
ALL CEILING SPEAKERS AND CEILING MICROPHONES ARE TO BE MOUNTED SYMMETRICAL
TO CENTERLINE OF TABLE WHICH MAY NOT BE CENTERLINE OF CEILING GRID.
TABLE HATCHES ARE SHOWN TO INDICATE NUMBER OF LOCATIONS IN TABLE WHICH
REQUIRE AV ACCOMMODATIONS. TABLE HATCH LOCATIONS AND PLATE REQUIREMENTS TO
BE COORDINATED WITH THE FURNITURE PACKAGE.
FLOOR BOXES SERVING TABLES ARE TO BE ALIGNED TO THE INTERIOR SIDE OF A TABLE
LEG ACCOMMODATINGVERTICAL POWER AND SIGNAL CABLE ROUTING.
TA - ELECTRICAL SYMBOLS LEGEND
SYMBOL DESCRIPTION
MOTORIZED PROJECTION SCREEN, PROJECTOR LIFT OR SHADE
WITH LOW-VOLTAGE INTERFACE; SUPPLIED WITH EQUIPMENT.
MOUNT ABOVE FINISHED CEILING UNLESS OTHERWISE INDICATED.
MAINTENANCE ACCESS TO BOX SHALL BE PROVIDED IN NON-
ACCESSIBLE CEILINGS. PROVIDE UTILITY GRADE 120VAC UNLESS
OTHERWISE INDICATED.
5-20R POWER RECEPTACLE,
DUPLEX 120VAC, 20AMP.
L INDICATES LOCKING RECEPTACLE
U INDICATES UPS POWER REQUIREMENT
6-20R POWER RECEPTACLE,
DUPLEX 208VAC, 20AMP.
TELECOM VOICE/DATA OUTLET BOX.
REFER TO TELECOM DRAWINGS FOR INSTALLATION DETAILS.
M
TA - EQUIPMENT TAG LEGEND
AV DEVICE TAG
REQUIRED DATA
REQUIRED AC
(DUPLEX, QUADPLEX, TWIST LOCK)
XX-X
REFER TO
"AUDIOVISUAL CONNECTIVITY - TYPICAL"
ON SHEET TA-001 FOR ADDITIONAL INFORMATION
5-20R POWER RECEPTACLE,
QUADPLEX 120VAC, 20AMP.
4-3 x16
3-3
2-410-1
WM32M
7-98
7-98
WM32M
7-98
P525-E7-75-E7-75P525
TA-601
TA-6015 TA-601
3-1
WM32M
TA-601
6-3 2-2
7-75-E P525-E
3-2
2-ENC
2-ENC 2-ENC
4-4 4-4 4-4 4-4
2-ENC
5-1 x8
5-2 5-2
4-1 4-1
2-2C 6-1 6-1
2-2C
6-16-1
2-2C 2-2C
4-2
6-2 6-2 2-2C2-2C
5-3
5-3
5-3
6-1 2-2C
L1 0' - 0"
7-98
WM32M
3'
- 1
1/ 4"
5'
- 2
0"
4'
- 1
1/ 4"
7' - 2 1/2"
2-2 6-3
7'
- 2
1/ 2"
6-1
2-2C
Level 1 0' - 0" L1 0' - 0"
7-98
WM32M
3-110-1
2-4
7-75-E P525-E
1'
- 6
"3'
- 1
1/ 4"
5'
- 2
4'
- 0
" 5'
- 7
2-2C
6-1
L1 0' - 0"
7-75
7-98
WM32MP525
4'
- 0
"5'
- 7
3'
- 1
1/ 4"
5'
- 2
2-2C
6-1
L1 0' - 0"
4'
- 0
"5'
- 7
7-75-E P525-E
5'
- 7
P-525 x3
1'
- 6
2-4 2-1
5'
- 2
WM32M
2-2
7'
- 2
1/ 2"
WM32M x2
3/4 " E
.C
(2 ) 3
/4" E
.C
(2 ) 3
/4" E
.C .0'
- 6
1 1 /2"
E .C
3/4 " E
.C
5-3 x2
5-2 x3
5-1 x8
2-2C x7
ACOUSTICS ● AUDIOVISUAL● IT ● SECURITY
1001 SIXTH AVENUE, 4TH FLOOR
NEW YORK, NY 10018
T 212 370 1776
WWW.CERAMIASSOCIATES.COM
THIS DOCUMENT AND THE IDEAS INCORPORATED HEREIN, AS AN
INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF CERAMI &
ASSOCIATES INC. AND IS NOT TO BE USED IN WHOLE OR IN PART, FOR ANY
OTHER PROJECT OR PURPOSE WITHOUT THE WRITTEN AUTHORIZATION
OF CERAMI & ASSOCIATES, INC.
© COPYRIGHT 2024 CERAMI & ASSOCIATES, INC. ALL RIGHTS RESERVED
PROJECT #: SCALE: DATE:
DRAWN BY: CHECKED BY:ENG. BY:
PROJECT NAME:
TITLE:
NOTES:
SHEET #:
CLIENT:
As indicated
COLUMBIA
ASSOCIATION
BOARDROOM
IMPROVEMENT
PROJECT
AUDIOVISUAL
ENLARGED VIEWS -
BOARDROOM
262110.0001 01/19/14
TA-601
AUDIOVISUAL DEVICE KEY
TAG DESCRIPTION
1-# EQUIPMENT RACK
1-1 EXISTING RACK TO REMAIN
2-# CONNECTIVITY
2-2 JUNCTION BOX (2 GANG); FOR AUDIOVISUAL CONNECTIVITY
2-2C CEILING MOUNTED JUNCTION BOX FOR AUDIOVISUAL CONNECTIVITY
2-4 JUNCTION BOX (4 GANG); FOR AUDIOVISUAL CONNECTIVITY
2-ENC HDMI VIDEO ENCODER
2-P EXISTING POWER TO REMAIN
WM32M IN-WALL BOX WITH INTEGRAL MOUNT
3-# CONTROL/SCHEDULING
3-1 CRESTRON TOUCH PANEL
3-2 TOUCH PANEL FOR ZOOM
3-3 TOUCH PANEL FOR TEAMS
3-4 EXISTING PRODUCTION CONTROL SURFACE TO REMAIN
3-5 EXISTING TRICASTER TO REMAIN
4-# AUDIO INPUT
4-1 WIRELESS MIC ANTENNA
4-2 MICROPHONE ARRAY; CEILING RECESSED
4-3 24" GOOSENECK MICROPHONE WITH MUTE BUTTON
4-4 WIRELESS GOOSENECK MICROPHONE WITH MUTE BUTTON
5-# AUDIO OUTPUT
5-1 EXISTING TO REMAIN CEILING CAN SPEAKERS
5-2 EXISTING TO REMAIN PENDANT SPEAKERS
5-3 NEW PENDANT SPEAKERS
6-# VIDEO ORIGIN/SOURCE
6-1 PTZ CAMERA; CEILING MOUNTED (PANASONIC AW-UE160)
6-2 PTZ CAMERA; CEILING MOUNTED (POLY E60)
6-3 POLY E70 TRACKING CAMERA
7-# VIDEO DISPLAY (TYPE 1)
7-21 21" TABLE MOUNTED DISPLAY; EXISTING TO REMAIN
7-32 32" FLAT PANEL DISPLAY; EXISTING TO REMAIN
7-75 75" FLAT PANEL DISPLAY; WALL MOUNTED
7-75-E 75" FLAT PANEL DISPLAY; WALL MOUNTED. EXISTING TO REMAIN
7-98 98" FLAT PANEL DISPLAY; WALL MOUNTED
P525 IN-WALL BOX; FOR FLAT PANEL DISPLAY CONNECTIVITY
P525-E IN-WALL BOX; FOR FLAT PANEL DISPLAY CONNECTIVITY. EXISTING TO REMAIN
10-# MISCELLANEOUS
10-1 Desktop Keyboard, Displays and Mouse (OFE)
REV. DATE DESCRIPTION
1 7/13/26 100% CD
1/4" = 1'-0"1 AV ENLARGED FLOOR PLAN - BOARDROOM
1/4" = 1'-0"2 AV ENLARGED RCP - BOARDROOM
EXISTING FLOOR PENETRATION
FOR CABLE PULL
1/2" = 1'-0"3 AV ELEVATION - BOARDROOM - NORTH WALL
1/2" = 1'-0"4 AV ELEVATION - BOARDROOM - EAST WALL
1/2" = 1'-0"5 AV ELEVATION - BOARDROOM - WEST WALL
1/2" = 1'-0"6 AV ELEVATION - BOARDROOM - SOUTH WALL
1/2" = 1'-0"7 AV CONDUIT RISER - BOARDROOM
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
NOTE:
DEVICE MOUNTING COORDINATION WITH ARCHITECTURE MILLWORK
REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR COORDINATED AV
INFRASTRUCTURE AND ELECTRICAL DEVICE LOCATIONS.
DISPLAYS ARE TO BE MOUNTED CENTERED ON THE CENTERLINE OF THE TABLE WHICH MAY
NOT BE THE CENTERLINE OF THE MOUNTING WALL.
STUD PLACEMENT TO BE COORDINATED WITH DISPLAY IN-WALL BOX MOUNTING TO KEEP
IN-WALL BOX ALONG THE CENTERLINE OF THE DISPLAY.
WHERE THE DISPLAYS ARE MOUNTED BACK-TO-BACK ON A COMMON PARTITION, THE
DISPLAY IN-WALL BOXES ARE TO BE OFFSET AROUND A CENTER STUD.
DISPLAY WIDTH AND HEIGHTS SHOWN ARE REPRESENTATIVE AND ARE TO BE CONFIRMED
WITH THE FINAL CONTRACTOR PROVIDED CUT-SHEETS PRIOR TO ROUGHING AND DISPLAY
RECESSES OR COORDINATING OTHER CRITICAL CLEARANCES.
WHEN RECESSED, PROVIDE A 2" MINIMUM CLEARANCE AROUND TOP, BOTTOM AND SIDES
OF DISPLAY.
ALL TOUCH PANEL BACKBOXES MOUNTED ON THE SAME WALL AS DISPLAYS ARE TO BE
HELD 12" CLEAR BETWEEN THE EDGE OF THE DISPLAY AND THE CENTERLINE OF THE
TOUCH PANEL BACKBOX.
ROOM SCHEDULING DISPLAY CABLING PENETRATIONS IN THE FLOOR/CEILING ARE TO BE
COORDINATED WITH EITHER SOLID PARTITION CENTERLINES OR, WHEN MOUNTED ON
GLASS, WITH THE CENTERLINE OF THE DOOR EXTRUSION TO ALLOW A NETWORK PATCH
CABLE TO BE RUN WITHIN THE EXTRUSION.
ALL CONTROL AND SCHEDULING DEVICE HEIGHTS TO BE COORDINATED WITH
ARCHITECTURAL ELEVATIONS AND MUST ALLOW THE TOP OF THE DEVICE TO BE UNDER 48"
PER ADA.
ALL CEILING SPEAKERS AND CEILING MICROPHONES ARE TO BE MOUNTED SYMMETRICAL
TO CENTERLINE OF TABLE WHICH MAY NOT BE CENTERLINE OF CEILING GRID.
TABLE HATCHES ARE SHOWN TO INDICATE NUMBER OF LOCATIONS IN TABLE WHICH
REQUIRE AV ACCOMMODATIONS. TABLE HATCH LOCATIONS AND PLATE REQUIREMENTS TO
BE COORDINATED WITH THE FURNITURE PACKAGE.
FLOOR BOXES SERVING TABLES ARE TO BE ALIGNED TO THE INTERIOR SIDE OF A TABLE
LEG ACCOMMODATINGVERTICAL POWER AND SIGNAL CABLE ROUTING.
TA - ELECTRICAL SYMBOLS LEGEND
SYMBOL DESCRIPTION
MOTORIZED PROJECTION SCREEN, PROJECTOR LIFT OR SHADE
WITH LOW-VOLTAGE INTERFACE; SUPPLIED WITH EQUIPMENT.
MOUNT ABOVE FINISHED CEILING UNLESS OTHERWISE INDICATED.
MAINTENANCE ACCESS TO BOX SHALL BE PROVIDED IN NON-
ACCESSIBLE CEILINGS. PROVIDE UTILITY GRADE 120VAC UNLESS
OTHERWISE INDICATED.
5-20R POWER RECEPTACLE,
DUPLEX 120VAC, 20AMP.
L INDICATES LOCKING RECEPTACLE
U INDICATES UPS POWER REQUIREMENT
6-20R POWER RECEPTACLE,
DUPLEX 208VAC, 20AMP.
TELECOM VOICE/DATA OUTLET BOX.
REFER TO TELECOM DRAWINGS FOR INSTALLATION DETAILS.
M
TA - EQUIPMENT TAG LEGEND
AV DEVICE TAG
REQUIRED DATA
REQUIRED AC
(DUPLEX, QUADPLEX, TWIST LOCK)
XX-X
REFER TO
"AUDIOVISUAL CONNECTIVITY - TYPICAL"
ON SHEET TA-001 FOR ADDITIONAL INFORMATION
5-20R POWER RECEPTACLE,
QUADPLEX 120VAC, 20AMP.
1-1
2-P
ACOUSTICS ● AUDIOVISUAL● IT ● SECURITY
1001 SIXTH AVENUE, 4TH FLOOR
NEW YORK, NY 10018
T 212 370 1776
WWW.CERAMIASSOCIATES.COM
THIS DOCUMENT AND THE IDEAS INCORPORATED HEREIN, AS AN
INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF CERAMI &
ASSOCIATES INC. AND IS NOT TO BE USED IN WHOLE OR IN PART, FOR ANY
OTHER PROJECT OR PURPOSE WITHOUT THE WRITTEN AUTHORIZATION
OF CERAMI & ASSOCIATES, INC.
© COPYRIGHT 2024 CERAMI & ASSOCIATES, INC. ALL RIGHTS RESERVED
PROJECT #: SCALE: DATE:
DRAWN BY: CHECKED BY:ENG. BY:
PROJECT NAME:
TITLE:
NOTES:
SHEET #:
CLIENT:
As indicated
COLUMBIA
ASSOCIATION
BOARDROOM
IMPROVEMENT
PROJECT
AUDIOVISUAL
ENLARGED VIEWS -
RACK ROOM
262110.0001 01/19/14
TA-602
AUDIOVISUAL DEVICE KEY
TAG DESCRIPTION
1-# EQUIPMENT RACK
1-1 EXISTING RACK TO REMAIN
2-# CONNECTIVITY
2-2 JUNCTION BOX (2 GANG); FOR AUDIOVISUAL CONNECTIVITY
2-2C CEILING MOUNTED JUNCTION BOX FOR AUDIOVISUAL CONNECTIVITY
2-4 JUNCTION BOX (4 GANG); FOR AUDIOVISUAL CONNECTIVITY
2-ENC HDMI VIDEO ENCODER
2-P EXISTING POWER TO REMAIN
WM32M IN-WALL BOX WITH INTEGRAL MOUNT
3-# CONTROL/SCHEDULING
3-1 CRESTRON TOUCH PANEL
3-2 TOUCH PANEL FOR ZOOM
3-3 TOUCH PANEL FOR TEAMS
3-4 EXISTING PRODUCTION CONTROL SURFACE TO REMAIN
3-5 EXISTING TRICASTER TO REMAIN
4-# AUDIO INPUT
4-1 WIRELESS MIC ANTENNA
4-2 MICROPHONE ARRAY; CEILING RECESSED
4-3 24" GOOSENECK MICROPHONE WITH MUTE BUTTON
4-4 WIRELESS GOOSENECK MICROPHONE WITH MUTE BUTTON
5-# AUDIO OUTPUT
5-1 EXISTING TO REMAIN CEILING CAN SPEAKERS
5-2 EXISTING TO REMAIN PENDANT SPEAKERS
5-3 NEW PENDANT SPEAKERS
6-# VIDEO ORIGIN/SOURCE
6-1 PTZ CAMERA; CEILING MOUNTED (PANASONIC AW-UE160)
6-2 PTZ CAMERA; CEILING MOUNTED (POLY E60)
6-3 POLY E70 TRACKING CAMERA
7-# VIDEO DISPLAY (TYPE 1)
7-21 21" TABLE MOUNTED DISPLAY; EXISTING TO REMAIN
7-32 32" FLAT PANEL DISPLAY; EXISTING TO REMAIN
7-75 75" FLAT PANEL DISPLAY; WALL MOUNTED
7-75-E 75" FLAT PANEL DISPLAY; WALL MOUNTED. EXISTING TO REMAIN
7-98 98" FLAT PANEL DISPLAY; WALL MOUNTED
P525 IN-WALL BOX; FOR FLAT PANEL DISPLAY CONNECTIVITY
P525-E IN-WALL BOX; FOR FLAT PANEL DISPLAY CONNECTIVITY. EXISTING TO REMAIN
10-# MISCELLANEOUS
10-1 Desktop Keyboard, Displays and Mouse (OFE)
REV. DATE DESCRIPTION
1/4" = 1'-0"1 AV ENLARGED FLOOR PLAN - RACK ROOM
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
NOTE:
DEVICE MOUNTING COORDINATION WITH ARCHITECTURE MILLWORK
REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR COORDINATED AV
INFRASTRUCTURE AND ELECTRICAL DEVICE LOCATIONS.
DISPLAYS ARE TO BE MOUNTED CENTERED ON THE CENTERLINE OF THE TABLE WHICH MAY
NOT BE THE CENTERLINE OF THE MOUNTING WALL.
STUD PLACEMENT TO BE COORDINATED WITH DISPLAY IN-WALL BOX MOUNTING TO KEEP
IN-WALL BOX ALONG THE CENTERLINE OF THE DISPLAY.
WHERE THE DISPLAYS ARE MOUNTED BACK-TO-BACK ON A COMMON PARTITION, THE
DISPLAY IN-WALL BOXES ARE TO BE OFFSET AROUND A CENTER STUD.
DISPLAY WIDTH AND HEIGHTS SHOWN ARE REPRESENTATIVE AND ARE TO BE CONFIRMED
WITH THE FINAL CONTRACTOR PROVIDED CUT-SHEETS PRIOR TO ROUGHING AND DISPLAY
RECESSES OR COORDINATING OTHER CRITICAL CLEARANCES.
WHEN RECESSED, PROVIDE A 2" MINIMUM CLEARANCE AROUND TOP, BOTTOM AND SIDES
OF DISPLAY.
ALL TOUCH PANEL BACKBOXES MOUNTED ON THE SAME WALL AS DISPLAYS ARE TO BE
HELD 12" CLEAR BETWEEN THE EDGE OF THE DISPLAY AND THE CENTERLINE OF THE
TOUCH PANEL BACKBOX.
ROOM SCHEDULING DISPLAY CABLING PENETRATIONS IN THE FLOOR/CEILING ARE TO BE
COORDINATED WITH EITHER SOLID PARTITION CENTERLINES OR, WHEN MOUNTED ON
GLASS, WITH THE CENTERLINE OF THE DOOR EXTRUSION TO ALLOW A NETWORK PATCH
CABLE TO BE RUN WITHIN THE EXTRUSION.
ALL CONTROL AND SCHEDULING DEVICE HEIGHTS TO BE COORDINATED WITH
ARCHITECTURAL ELEVATIONS AND MUST ALLOW THE TOP OF THE DEVICE TO BE UNDER 48"
PER ADA.
ALL CEILING SPEAKERS AND CEILING MICROPHONES ARE TO BE MOUNTED SYMMETRICAL
TO CENTERLINE OF TABLE WHICH MAY NOT BE CENTERLINE OF CEILING GRID.
TABLE HATCHES ARE SHOWN TO INDICATE NUMBER OF LOCATIONS IN TABLE WHICH
REQUIRE AV ACCOMMODATIONS. TABLE HATCH LOCATIONS AND PLATE REQUIREMENTS TO
BE COORDINATED WITH THE FURNITURE PACKAGE.
FLOOR BOXES SERVING TABLES ARE TO BE ALIGNED TO THE INTERIOR SIDE OF A TABLE
LEG ACCOMMODATINGVERTICAL POWER AND SIGNAL CABLE ROUTING.
TA - ELECTRICAL SYMBOLS LEGEND
SYMBOL DESCRIPTION
MOTORIZED PROJECTION SCREEN, PROJECTOR LIFT OR SHADE
WITH LOW-VOLTAGE INTERFACE; SUPPLIED WITH EQUIPMENT.
MOUNT ABOVE FINISHED CEILING UNLESS OTHERWISE INDICATED.
MAINTENANCE ACCESS TO BOX SHALL BE PROVIDED IN NON-
ACCESSIBLE CEILINGS. PROVIDE UTILITY GRADE 120VAC UNLESS
OTHERWISE INDICATED.
5-20R POWER RECEPTACLE,
DUPLEX 120VAC, 20AMP.
L INDICATES LOCKING RECEPTACLE
U INDICATES UPS POWER REQUIREMENT
6-20R POWER RECEPTACLE,
DUPLEX 208VAC, 20AMP.
TELECOM VOICE/DATA OUTLET BOX.
REFER TO TELECOM DRAWINGS FOR INSTALLATION DETAILS.
M
TA - EQUIPMENT TAG LEGEND
AV DEVICE TAG
REQUIRED DATA
REQUIRED AC
(DUPLEX, QUADPLEX, TWIST LOCK)
XX-X
REFER TO
"AUDIOVISUAL CONNECTIVITY - TYPICAL"
ON SHEET TA-001 FOR ADDITIONAL INFORMATION
5-20R POWER RECEPTACLE,
QUADPLEX 120VAC, 20AMP.
7-32 P525 3-1
3-4
3-5 7-21
7-21
TA-603 2
L1 0' - 0"
2'
- 6
4'
- 9
4'
- 0
7-21
7-32 P525
7-21
3-5 3-1 3-4
ACOUSTICS ● AUDIOVISUAL● IT ● SECURITY
1001 SIXTH AVENUE, 4TH FLOOR
NEW YORK, NY 10018
T 212 370 1776
WWW.CERAMIASSOCIATES.COM
THIS DOCUMENT AND THE IDEAS INCORPORATED HEREIN, AS AN
INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF CERAMI &
ASSOCIATES INC. AND IS NOT TO BE USED IN WHOLE OR IN PART, FOR ANY
OTHER PROJECT OR PURPOSE WITHOUT THE WRITTEN AUTHORIZATION
OF CERAMI & ASSOCIATES, INC.
© COPYRIGHT 2024 CERAMI & ASSOCIATES, INC. ALL RIGHTS RESERVED
PROJECT #: SCALE: DATE:
DRAWN BY: CHECKED BY:ENG. BY:
PROJECT NAME:
TITLE:
NOTES:
SHEET #:
CLIENT:
As indicated
COLUMBIA
ASSOCIATION
BOARDROOM
IMPROVEMENT
PROJECT
AUDIOVISUAL
ENLARGED VIEWS -
PRODUCTION STUDIO
262110.0001 01/19/14
TA-603
AUDIOVISUAL DEVICE KEY
TAG DESCRIPTION
1-# EQUIPMENT RACK
1-1 EXISTING RACK TO REMAIN
2-# CONNECTIVITY
2-2 JUNCTION BOX (2 GANG); FOR AUDIOVISUAL CONNECTIVITY
2-2C CEILING MOUNTED JUNCTION BOX FOR AUDIOVISUAL CONNECTIVITY
2-4 JUNCTION BOX (4 GANG); FOR AUDIOVISUAL CONNECTIVITY
2-ENC HDMI VIDEO ENCODER
2-P EXISTING POWER TO REMAIN
WM32M IN-WALL BOX WITH INTEGRAL MOUNT
3-# CONTROL/SCHEDULING
3-1 CRESTRON TOUCH PANEL
3-2 TOUCH PANEL FOR ZOOM
3-3 TOUCH PANEL FOR TEAMS
3-4 EXISTING PRODUCTION CONTROL SURFACE TO REMAIN
3-5 EXISTING TRICASTER TO REMAIN
4-# AUDIO INPUT
4-1 WIRELESS MIC ANTENNA
4-2 MICROPHONE ARRAY; CEILING RECESSED
4-3 24" GOOSENECK MICROPHONE WITH MUTE BUTTON
4-4 WIRELESS GOOSENECK MICROPHONE WITH MUTE BUTTON
5-# AUDIO OUTPUT
5-1 EXISTING TO REMAIN CEILING CAN SPEAKERS
5-2 EXISTING TO REMAIN PENDANT SPEAKERS
5-3 NEW PENDANT SPEAKERS
6-# VIDEO ORIGIN/SOURCE
6-1 PTZ CAMERA; CEILING MOUNTED (PANASONIC AW-UE160)
6-2 PTZ CAMERA; CEILING MOUNTED (POLY E60)
6-3 POLY E70 TRACKING CAMERA
7-# VIDEO DISPLAY (TYPE 1)
7-21 21" TABLE MOUNTED DISPLAY; EXISTING TO REMAIN
7-32 32" FLAT PANEL DISPLAY; EXISTING TO REMAIN
7-75 75" FLAT PANEL DISPLAY; WALL MOUNTED
7-75-E 75" FLAT PANEL DISPLAY; WALL MOUNTED. EXISTING TO REMAIN
7-98 98" FLAT PANEL DISPLAY; WALL MOUNTED
P525 IN-WALL BOX; FOR FLAT PANEL DISPLAY CONNECTIVITY
P525-E IN-WALL BOX; FOR FLAT PANEL DISPLAY CONNECTIVITY. EXISTING TO REMAIN
10-# MISCELLANEOUS
10-1 Desktop Keyboard, Displays and Mouse (OFE)
REV. DATE DESCRIPTION
1 7/13/26 100% CD
1/4" = 1'-0"1 AV ENLARGED FLOOR PLAN - PRODUCTION STUDIO
1/2" = 1'-0"2 AV ELEVATION - PRODUCTION STUDIO - EAST WALL
ACOUSTICS ● AUDIOVISUAL● IT ● SECURITY
1001 SIXTH AVENUE, 4TH FLOOR
NEW YORK, NY 10018
T 212 370 1776
WWW.CERAMIASSOCIATES.COM
THIS DOCUMENT AND THE IDEAS INCORPORATED HEREIN, AS AN
INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF CERAMI &
ASSOCIATES INC. AND IS NOT TO BE USED IN WHOLE OR IN PART, FOR ANY
OTHER PROJECT OR PURPOSE WITHOUT THE WRITTEN AUTHORIZATION
OF CERAMI & ASSOCIATES, INC.
© COPYRIGHT 2024 CERAMI & ASSOCIATES, INC. ALL RIGHTS RESERVED
PROJECT #: SCALE: DATE:
DRAWN BY: CHECKED BY:ENG. BY:
PROJECT NAME:
TITLE:
NOTES:
SHEET #:
CLIENT:
As indicated
COLUMBIA
ASSOCIATION
BOARDROOM
IMPROVEMENT
PROJECT
AUDIOVISUAL DETAILS
262110.0001 01/19/14
TA-701
REV. DATE DESCRIPTION
1 7/13/26 100% CD
1 1/2" = 1'-0"3 PANASONIC AW-UE160
1" = 1'-0"4 PAC525
CT CT
LAN
HDMI OUTLAN HDMI IN
SPK OUT
SPK OUT
SPK OUT
SPK OUT
LAN
POE++
LANHDMI
TEAMS CODEC
VIDEO DECODER DISPLAY
AUDIO DSP
AUDIO AMPLIFIER
VIDEO ENCODER
MICROPHONE
TABLE BOX
ZOOM CAMERA (X5)
HDMI
CEILING SPEAKER
BOARDROOM
AV EQUIPMENT RACK WALL DISPLAYS (X5)
CONFERENCE TABLE
ZOOM CAMERAS
BOARDROOM CEILING
BAL
MUTE RING
LINK
AES67
AUDIO TRANSPORTER
BAL
LINK
AV NETWORK SWITCH
MICROPHONE
BAL
MUTE RING
LINK
MICROPHONE
BAL
MUTE RING
LINK
MICROPHONE
BAL
MUTE RING
LINK
BAL
LINK
BAL
LINK
BAL
LINK
16 MICROPHONES
16 MUTE RINGS
4 AUDIO TRANSPORTERS
ZOOM TOUCH PANEL
POE FACILITY LAN
AUDIO AMPLIFIER
SPK OUT
SPK OUT
LINE IN
AV NETWORK SWITCH
LAN (X5) VIDEO ENCODER (X8)
CEILING SPEAKER
CEILING SPEAKER
CEILING SPEAKER
SPK OUT
SPK OUT
SPK OUT
SPK OUT
CEILING SPEAKER
CEILING SPEAKER
CEILING SPEAKER
CEILING SPEAKER
MIX-MINUS
OVERFLOW ROOM CEILING
CEILING SPEAKER (X2)
CEILING SPEAKER (X3)
CONTROL PROCESSOR
LAN
AV NETWORK SWITCH
TABLE BOX
HDMI LAN
VIDEO ENCODER
HDMI AV NETWORK SWITCH
TABLE BOX
HDMI LAN
VIDEO ENCODER
HDMI AV NETWORK SWITCH
FLOOR BOX
TEAMS CAMERAS
POE+
TEAMS CAMERA (X3)
LLN NETWORK SWITCH
LLN NETWORK SWITCH
POE+ (X3)
TEAMS CODEC
LLN
AUDIO DSP LINE IN
POE+
AV NETWORK
SWITCH
AV NETWORK
SWITCH
TEAMS CAMERA (X3)
FACILITY LAN
DRIVER'S SEAT
DRIVER'S SEAT
HDMI INHDMI OUT
VIDEO DECODER
LANAV NETWORK
SWITCH
HDMI OUT LAN
VIDEO ENCODER
HDMI IN AV NETWORK SWITCH
HDMI OUT LAN
VIDEO ENCODER
HDMI IN AV NETWORK SWITCH
CEILING
LINE OUT
LINE OUT
LINE IN
AV NETWORK
SWITCH
AV NETWORK
SWITCH
QUAD WIRELESS MIC RECEIVER
RFWIRELESS MIC ANTENNA
RFWIRELESS MIC ANTENNA
LANAV NETWORK
SWITCH
RF
WIRELESS MIC ANTENNA
WIRELESS MIC RECEIVER
RF
WIRELESS MIC ANTENNA
WIRELESS MIC RECEIVER
POE
CEILING MICROPHONE
AV NETWORK SWITCH
CONTROL TOUCH PANEL
POE
TEAMS TOUCH PANEL
POE FACILITY LAN
AV NETWORK SWITCH
LINE OUT
LINE OUT
LINE OUT
LINE OUT
TEAMS CODEC
ZOOM CODEC
ZOOM CODEC
AUDIO DSP LINE IN
LAN
ZOOM CODEC
USB A
AUDIO DSP LINE IN
POE+FACILITY LAN
HDMI INHDMI OUT
VIDEO DECODER
LANAV NETWORK
SWITCH
HDMI OUT LAN
VIDEO ENCODER
HDMI IN AV NETWORK SWITCH
HDMI OUT LAN
VIDEO ENCODER
HDMI IN AV NETWORK SWITCH
AUDIO DSP LINE IN
LAN (X8) VIDEO DECODER (X8)
LANTEAMS TOUCH PANEL
LANZOOM TOUCH PANEL
LAN (X4)AUDIO TRANSPORTER (X4)
LAN
LAN
LAN
LAN
LAN
TRICASTER
QUAD WIRELESS MIC RECEIVER
AUDIO DSP
AUDIO AMPLIFIER
LAN (X2)
LAN (X3)
CONTROL PROCESSOR
LAN LAN
HDMI OUT
VIDEO DECODER
LAN
MONITOR
HDMI INAV NETWORK
SWITCH
LAN LAN
HDMI OUT
VIDEO DECODER
LAN
MONITOR
HDMI INAV NETWORK
SWITCH
LAN LAN
TABLE BOX
HDMI LAN
VIDEO ENCODER
HDMI AV NETWORK SWITCH
WALL BOX
FLOOR BOX
BAL OUT
ALS TRANSMITTER
BAL IN
CONTROL TOUCH PANEL (X2)
PRODUCTION MONITOR (X3)
LANFACILITY LAN
USBUSB
MOUSE/KEYBOARD
LINE OUT
LINE OUT
AUDIO DSP
AUDIO DSP
LINE OUT
LINE OUT
AUDIO DSP
AUDIO DSP
LINE IN
TEAMS CODEC
LINE IN
TEAMS CODEC
LINE IN
ZOOM CODEC
LINE IN
ZOOM CODEC
LAN (X8)
HDMI OUT
NDI DECODER
LANAV NETWORK
SWITCH USB
HDMI TO USB CONVERTER
HDMI IN
LAN NDI DECODER
FLOOR BOX
LAN
POE++ INJECTOR (X5)
POE++
ACOUSTICS ● AUDIOVISUAL● IT ● SECURITY
1001 SIXTH AVENUE, 4TH FLOOR
NEW YORK, NY 10018
T 212 370 1776
WWW.CERAMIASSOCIATES.COM
THIS DOCUMENT AND THE IDEAS INCORPORATED HEREIN, AS AN
INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF CERAMI &
ASSOCIATES INC. AND IS NOT TO BE USED IN WHOLE OR IN PART, FOR ANY
OTHER PROJECT OR PURPOSE WITHOUT THE WRITTEN AUTHORIZATION
OF CERAMI & ASSOCIATES, INC.
© COPYRIGHT 2024 CERAMI & ASSOCIATES, INC. ALL RIGHTS RESERVED
PROJECT #: SCALE: DATE:
DRAWN BY: CHECKED BY:ENG. BY:
PROJECT NAME:
TITLE:
NOTES:
SHEET #:
CLIENT:
12" = 1'-0"
COLUMBIA
ASSOCIATION
BOARDROOM
IMPROVEMENT
PROJECT
AUDIOVISUAL SYSTEM
FLOW DIAGRAMS -
BOARDROOM
262110.0001 01/19/14
TA-801
DP IN
PRODUCTION MONITOR
PRODUCTION STUDIO
DESK
MINI DP
OUT
TRICASTER
USBMOUSE/KEYBOARD
LAN
LAN
FACILITY LAN
AV NETWORK
SWITCH
HDMI OUT
VIDEO DECODER
LAN HDMI INAV NETWORK
SWITCH
MINI DP
OUT
CONTROL TOUCH PANEL
POE AV NETWORK SWITCH
LAN
PRODUCTION MONITOR
DP IN LAN
PRODUCTION MONITOR
DP IN LAN AV NETWORK SWITCHMINI DP
OUT
PRODUCTION CONTROLLER
USB USB
PHONES OUT HEADPHONES
AV NETWORK SWITCH
AV NETWORK SWITCH
HDMI OUT
VIDEO DECODER
LAN HDMI INAV NETWORK
SWITCH
HDMI OUT
VIDEO DECODER
LAN HDMI INAV NETWORK
SWITCH
LOGO
PATCH PANEL
LLN NETWORK SWITCH
BRUSH PANEL
CONTROL PROCESSOR
BLANK
NDI DECODER / HDMI-USB CONV
VIDEO DECODER
ZOOM CODEC
BLANK
VIDEO DECODER
TEAMS CODEC
VIDEO ENCODER (X2)
WIRELESS MIC RECEIVER
BLANK
AUDIO DSP
VENT PANEL
AUDIO AMPLIFIER
VENT PANEL
VENT PANEL
AUDIO AMPLIFIER
STORAGE
MICROPHONE CHARGING
AV NETWORK SWITCH
BRUSH PANEL
PATCH PANEL
VIDEO ENCODER (X2)
HDMI OUT
VIDEO DECODER
LAN HDMI INAV NETWORK
SWITCH
ACOUSTICS ● AUDIOVISUAL● IT ● SECURITY
1001 SIXTH AVENUE, 4TH FLOOR
NEW YORK, NY 10018
T 212 370 1776
WWW.CERAMIASSOCIATES.COM
THIS DOCUMENT AND THE IDEAS INCORPORATED HEREIN, AS AN
INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF CERAMI &
ASSOCIATES INC. AND IS NOT TO BE USED IN WHOLE OR IN PART, FOR ANY
OTHER PROJECT OR PURPOSE WITHOUT THE WRITTEN AUTHORIZATION
OF CERAMI & ASSOCIATES, INC.
© COPYRIGHT 2024 CERAMI & ASSOCIATES, INC. ALL RIGHTS RESERVED
PROJECT #: SCALE: DATE:
DRAWN BY: CHECKED BY:ENG. BY:
PROJECT NAME:
TITLE:
NOTES:
SHEET #:
CLIENT:
12" = 1'-0"
COLUMBIA
ASSOCIATION
BOARDROOM
IMPROVEMENT
PROJECT
AUDIOVISUAL SYSTEM
FLOW DIAGRAMS -
PRODUCTION STUDIO &
RACK
262110.0001 01/19/14
TA-802
| TA-000 - AUDIOVISUAL COVER SHEET |
| TA-001 - AUDIOVISUAL GENERAL NOTES |
| TA-201 - AUDIOVISUAL OVERALL FLOOR PLAN |
| TA-301 - AUDIOVISUAL OVERALL RCP |
| TA-601 - AUDIOVISUAL ENLARGED VIEWS - BOARDROOM |
| TA-602 - AUDIOVISUAL ENLARGED VIEWS - RACK ROOM |
| TA-603 - AUDIOVISUAL ENLARGED VIEWS - PRODUCTION STUDIO |
| TA-701 - AUDIOVISUAL DETAILS |
| TA-801 - AUDIOVISUAL SYSTEM FLOW DIAGRAMS - BOARDROOM |
| TA-802 - AUDIOVISUAL SYSTEM FLOW DIAGRAMS - PRODUCTION STUDIO & RACK |
File details come from the government source that posted it. Updated .