Attch 1 - Salient Characteristics.pdf

PDF 121 KB Posted

Attached to
129 OG - Expandable ISU
Solicitation number
W50S8X25QA022
Issued by

About this file

This document is a Salient Characteristics/Product Description for an Expandable ISU (Integrated Support Unit) from the Department of the Air Force, Headquarters 129th Rescue Wing at Moffett Air National Guard Base in California. The Expandable ISU is designed to meet deployment requirements for a mobile Rescue Operations Center (ROC), providing forward troops with a secure, classified communications space for conducting rescue missions in austere environments.

The minimum requirements for the Expandable ISU include being air-certified and forkliftable onto C-130, C-17, and C-5 airplanes, limited to one pallet position when stowed. Key specifications include two retractable walls with tools, D-rings for cargo straps, a 60A power support cable of at least 50 feet, shore power cable, LED lighting, a built-in environmental control unit, a gas generator with 7,500 watts of running power, and a weather-tight personnel area with a cipher lock. Additional features include a preferred tan color, smoke detector, and fire extinguisher, emphasizing the unit's mobility, security, and operational effectiveness in challenging environments.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE AIR FORCE

HEADQUARTERS 129TH RESCUE WING (ACC)

MOFFETT AIR NATIONAL GUARD BASE CALIFORNIA

THAT OTHERS MAY LIVE

Salient Characteristics/Product Description

1. The Expandable ISU will allow the 129 OSS/IN to meet the deployment requirement for a mobile Rescue Operations Center (ROC) as required by UTC PFEQS. This equipment will supply forward troops with a secure space and classified communications to conduct rescue missions in an austere environment. Based on threat capabilities, this requirement must be highly mobile to satisfy the survivability requirement that future fights will demand.

2. Minimum requirements for Expandable ISU:

a. Air certified and “forkliftable” onto C-130, C-17, and C-5 airplanes.

i. Limited to one pallet position in stowed configuration

b. 2 retractable walls with included tools

c. D-rings on floor for cargo straps to secure equipment

d. 1 power support cable, 60A, at least 50 ft

e. Shore power cable included

f. Center ceiling LED lighting, white or blue

g. 1 built-in environmental control unit

h. 1 gas generator with at least 7,500 watts of running power

i. 1 personnel, weather tight with cipher lock

j. Preferred color: tan

k. Smoke detector and fire extinguisher

File details come from the government source that posted it. Updated .