Attch 1 - Salient Characteristics.pdf
PDF 125 KB Posted
- Attached to
- 129 OG - Expandable ISU
- Solicitation number
- W50S8X25QA022
About this file
This document is a Salient Characteristics/Product Description for an Expandable Integrated Support Unit (ISU) issued by the Department of the Air Force, Headquarters 129th Rescue Wing at Moffett Air National Guard Base in California, dated 19 Sep 2025.
The ISU is designed as a mobile Rescue Operations Center (ROC) with specific deployment requirements, including air certification for C-130, C-17, and C-5 airplanes, and the ability to transition from stowed to full configuration in less than 15 minutes. Key technical specifications include: a single-phase power panel supporting 60A draw for equipment like 8 laptops and 4 monitors, 2 retractable walls, 4 D-rings for cargo straps, a built-in shore power cable receiver, integrated environmental control unit, weather-tight personnel door with cipher lock, and smoke and carbon monoxide detectors. The preferred color is tan, with white or green also acceptable. The unit must be forkliftable, support generator power, and include LED ceiling lighting.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment W50S8X25QA0220001 SF 30.pdf | ||
| Attch 1 - Salient Characteristics.pdf | ||
| Solicitation - W50S8X25QA022.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF THE AIR FORCE
HEADQUARTERS 129TH RESCUE WING (ACC)
MOFFETT AIR NATIONAL GUARD BASE CALIFORNIA
THAT OTHERS MAY LIVE
Salient Characteristics/Product Description 19 Sep 2025
1. The expandable ISU will meet deployment requirements for a mobile Rescue Operations
Center (ROC). This equipment will provide secure space for classified communications and mission planning in multiple environments. This ISU should be agile, meaning it should transition from stowed configuration to full configuration in less than 15 min and must be capable of being moved by forklift multiple times per day.
2. Minimum requirements for Expandable ISU:
a. Air certified and “forkliftable” onto C-130, C-17, and C-5 airplanes.
i. Limited to one pallet position in stowed configuration
b. Must have 2 retractable walls with included tools (if applicable)
i. An example a of tool would be a crank hook that operates jacks to level ISU
c. Walls must be capable of transitioning from stowed configuration to open configuration, and vice versa, in less than 15 minutes with a two-person team
d. Must have at least 4 D-rings built into the floor for cargo straps
e. The power panel must support at least 60A power draw
i. Must be single phase
• Expected equipment is:
• At least 8 laptops
• At least 4 55” monitors
• 3 routers
• 1 antenna
• 4 personal radios
• ECU
ii. Must be capable of switching to generator power and running off a 7,500 watt generator
f. Must have at least 50 ft cable included for shore power
i. Must have built-in receiver to support provided shore power cable
g. Must have built-in ceiling LED lighting
i. Preferred color: white
h. Must have integrated environmental control unit (ECU), meaning the ISU has a designated location that is designed to house provided ECU when ECU is on and ISU is in operational configuration. ECUs that take up floor space are not preferred.
i. Must have at least 1 weather-tight personnel door with cipher lock
j. Preferred color of ISU: tan
i. Acceptable: white or green
k. Must come with smoke and carbon monoxide detectors