This document is an asbestos and lead-based paint survey report for the Clatsop County Courthouse located at 749 Commercial Street in Astoria, Oregon. The report summarizes the findings of a comprehensive inspection conducted between September 6 and September 22, 2006. Asbestos-containing materials were identified in the basement, including floor tiles and pipe insulation. On the first floor, additional asbestos-containing floor tiles and pipe insulation were found. The report also includes information on materials that tested negative for asbestos. A total of 20 representative paint chip samples were collected and analyzed, with varying lead paint levels found.
The Clatsop County Courthouse is the subject of an upcoming security improvement project, which includes remodeling the basement entry, installing holding cells, upgrading the District Attorney's Office reception desk, elevator modernization, and replacing historic windows. The project will be conducted by Clatsop County and the City of Astoria in the state of Oregon.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Clatsop County Courthouse
General Information 1.1
Clatsop County prepared for:
AHERA Certificates
Inspection Summary 1.2
749 Commercial Street Astoria, OR 97103
Sample Inventories Laboratory Data
Not Numbered Not Numbered 2.1
Asbestos and Limited Lead- Based Paint Survey Report
4412 SW Corbett Avenue
Portland, OR 97239
503.248.1939
503.248.0223
888.248.1939
MAIN
FAX
TOLLFREE
October 2006 Project #: 19786.001
DDIEFFENBACH
Textbox
ATTACHMENT "C"
749 Commercial StreetAsbestos and Limited Lead- Based Paint Survey
Report Astoria, OR 97103
749 Commercial Street
BUILDING DATA
Clatsop County Courthouse
Astoria, OR 97103
CLIENT DATA
Clatsop County 749 Commerical Street Astoria, OR 97103
Square Footage:
Year Built:
Construction Information:
39,000 SF
Brick and stone exterior, lath / plaster and gypsum board walls and ceilings, radiant heating with local HVAC units serving specific rooms/areas.
• The type, location and approximate quantity of suspect asbestos-containing materials;
• Bulk sampling of selected suspect building materials;
• Laboratory analytical data of bulk materials sampled
SURVEY SCOPE
PBS endeavored to locate all the suspect asbestos-containing materials in the building; however, suspect asbestos-containing materials may be present concealed within wall, ceiling, or floor spaces. If suspect materials are uncovered during demolition activities that are not identified in this report, testing should be performed prior to impact.
PBS has conducted a physical inspection of the building, compiled this report consistent with the survey scope, and certifies that the information is correct and accurate within the standards of professional quality and contractual obligations.
PBS Engineering and Environmental has performed a general asbestos survey of accessible building areas in accordance with OSHA in 29 CFR 1910.1001 and compiled a report with the following information:
GENERAL INFORMATION
Project Manager/Prime Inspector
1.1 Report Date: October 2006
Project #: 19786.001
Bob Kleckner
PDR-06-1539A
DateSignature
Accreditation #:
INSPECTION SUMMARY
Astoria, OR 97103 749 Commercial StreetAsbestos and Limited Lead- Based Paint Survey
Report
9/6/2006 B. Kleckner 9/7/2006 B. Kleckner
DATES SURVEYED BY ACTIVITY
Survey and Sampling Survey and Sampling
PBS Engineering and Environmental has investigated accessible areas inside of the building(s) to locate suspect asbestos-containing building materials (ACBM). Suspect materials may be present in concealed areas (e.g. behind walls and under carpet). The findings are listed below.
ASBESTOS MATERIALS
The following materials either tested positive, or, based on the experience of PBS field personnel, were not tested and should be considered asbestos-containing. Materials that had mixed results are considered positive. Materials not sampled may not contain asbestos and should be tested to verify asbestos content prior to impact through demolition, renovation, etc.
(+) Tested Positive, (M) Mixed Results, (P) Presumed Positive, (T) Previously Tested Positive.
Approx. QuantityResult Material (type) Location
9/8/2006 B. Kleckner Survey and Sampling 9/22/2006 B. Kleckner Survey and Sampling
1,300 SFBasement: Jury Room, Clerk Office, Conference Room, Judge Chambers, Judge Administrative Assistant, and Associated Corridor. Beige/Olive Tile Under Carpet.
Vinyl Floor Tile (01)(+)
1,450 SFBasement; Courtroom;
Brown Tile Under Carpet.
Vinyl Floor Tile (03)(+)
100 LFBasement; Server Room Above Lay-in Ceiling Tile (LCT), Women's Restroom Above LCT, Conference Room West of Clerks Office.
Mag Pipe Insulation(+)
1.2 Report Date: October 2006
Project #: 19786.001
Astoria, OR 97103 749 Commercial StreetAsbestos and Limited Lead- Based Paint Survey
Report
The following materials tested negative based on ASHARA sampling minimums and testing by NVLAP participating laboratories.
Although no asbestos was detected, it is possible that further sampling could indicate asbestos content. It may be prudent to test prior to impact through demolition, renovation, etc.
MATERIALS WHICH TESTED NEGATIVE FOR ASBESTOS
Material (type) Location
1,100 SF1st Floor; Juvenile Conference Room, Adjacent Storage Room East, Adjacent Mail Room, Adjacent Storage Room West. Above LCT and on Juvenile Conference Room North Wall. This material has tested less than one percent asbestos via point count analysis.
Glued-on Ceiling Tiles (01)(M)
820 SF1st Floor; West Storage Room; Beige/Olive Tile Under Carpet.
Vinyl Floor Tile (04)(+)
150 LF1st Floor; SW Conference Room, West Storage Room, NW Storage Room, Juvenile Conference Room, North End of Main Lobby, Court Clerk Vestibule Area, Court Clerk East File Room, Central Services Office and Centeral Services SE Corner Office.
Mag Pipe Insulation(+)
2,500 SF2nd Floor; Courtroom Ceiling and Walls. This material has tested less than one percent asbestos via point count analysis.
Glued-on Ceiling Tiles (01)(M)
Black Mastic Under Floor Tile (01) Basement; Jury Room, Clerk Office, Adjacent Conference Room, Judge
1.3
Astoria, OR 97103 749 Commercial StreetAsbestos and Limited Lead- Based Paint Survey
Report
Chambers, Judge Admin. Assistant, and Associated Corridor.
Black Mastic Under VAT (04) 1st Floor; West Storage Room.
Black Residual Mastic Under Carpet Basement Main Corridor @ South
Entrance.
Built-up Roofing (03) Roofing Layer Under Existing Roofing
System and Associated Plywood Substrate.
Built-up Roofing (Field) (01) Main Roof Built-up Roofing (Parapet) (02) Main Roof Gypsum Wallboard/Joint Compd. Throughout Building Lay-in Ceiling Tile (2x4 Deep Fissure) (05) 2nd Floor; Office South of DA File
Room.
Lay-in Ceiling Tile (2x4 Pock Mark Pattern) (03) 1st Floor; Court Clerk Break Room and
Adjacent Office/Storage.
Lay-in Ceiling Tile (2x4 Random Fissure w/ pin perf) (01)
Basement; Main Corridor, Courtroom, Courtroom hallway, Judge and Jury Restrooms, Judge Office, Judge Admin. Assistant Office, Jury Room, Clerk Office, SE Conference Room, South Storage Room, Men's and Women's Restroom, SW Conference Room, Court Staff Office Area, Court Staff West Office, Court Staff Manager's Office, Law Library, Law Library Witness Rooms, Server Room..
Lay-in Ceiling Tile (2x4 Random Fissure w/ Pin Perf) (02)
1st Floor; Central Services and Associated Offices, SW Conference Room and Associated Vestibule, West Storage Rooms, NW Storage Room, Juvenile Conference Room and Associated Storage and Mail Rooms, Court Clerk and Associated Vestibule, Offices, and East File Room.
1.4
Astoria, OR 97103 749 Commercial StreetAsbestos and Limited Lead- Based Paint Survey
Report
Lay-in Ceiling Tile (2x4 Random Fissure w/ Pin Perf) (04)
2nd Floor; Judge Chambers Office, Judge Chambers Copy Fax Room, Corridor Outside Judge Chambers, Docket Planning, Victim's Services, Office North of Victims Services Office, DA Vestibule, DA Reception Area and Office East of DA Reception.
Lay-in Ceiling Tile (2x4 Textured w/ Pin Perf) (06) 2nd Floor; Assistant DA Office and Adjacent Offices and Hallway.
Sheet Floor Covering (Beige w/ Line Pattern) (07) 2nd Floor; Judge Chamber's Restroom.
Sheet Floor Covering (Brown Herringbone Pattern) (06)
1st Floor; Central Services Vault.
Sheet Floor Covering (Brown Marble) (10) 1st Floor; Central Services Vault.
Sheet Floor Covering (Brown Mosaic Pattern) (03) Basement; Server Rooom.
Sheet Floor Covering (Brown w/ Black Mastic) (09) 1st Floor; Storage and Mail Room
Adjacent East of the Juvenile Conference Room.
Sheet Floor Covering (Grey Mosaic Pattern) (04) Basement; Jury Restroom, Judge Restroom.
Sheet Floor Covering (Grey Square Pattern) (02) Basement; Break Room.
Sheet Floor Covering (Red Sand Pattern) (08) 2nd Floor Jury Room Restroom.
Sheet Floor Covering (Teal Mosaic Pattern) (01) Basement: Men's and Women's
Restroom.
Sheet Floor Covering (White w/ bule Diamonds) (05) 1st Floor; West Vaut North and South
Entrance Pads.
Stapled-on Ceiling Tile (1x1 Peg Hole Pattern) 1st Floor; SW Conference Room, West
Storage Rooms, Court Clerk Office and Associated Vestibule, East File Room, and Break Room.
Vinyl Floor Tile/ Brown Mastic (Beige Tile) (06) 1st Floor; Court Clerk Office and Associated Vestibule, Offices, Open Offices, and East File Room.
Wall and Ceiling Plaster Throughout Building Yellow Mastic Under Floor Tile (03) Basement; Courtroom.
1.5
Astoria, OR 97103 749 Commercial StreetAsbestos and Limited Lead- Based Paint Survey
Report
BACKGROUND
ASBESTOS SUMMARY
BASEMENT
Asbestos-containing floor tile was identified under carpet in the Courtroom, SE Jury Room, Clerk's Office, SE Conference Room, Judge Chambers, Judge Assistance Office and associated Hallway. Mastics associated with these asbestos-containing tiles tested negative for asbestos.
Asbestos-containing pipe insulation was identified above lay-in ceiling tile systems in the Server Room, Boiler Room/Server Room Vestibule, and Women's Restroom.
All other suspect materials identified and sampled in the basement tested negative for asbestos.
See the "Materials Which Tested Negative for Asbestos" section of this report.
1ST FLOOR
Asbestos-containing floor tile was identified in the storage room located on the west side of the floor. The black associated mastic tested negative for asbestos.
Asbestos-containing pipe insulation was identified in the Central Services office, Central Services SE office, SW conference room, west storage room, NW storage room, juvenile conference room, main corridor, court clerk open office area and file room
Mixed results were obtained for glued-on ceiling and wall tiles located in the NW Storage Room, Juvenile Conference Room and associated Storage Room and Mail Room. The results are mixed with the highest concentration at less than one percent. Until further sampling of this material is performed, it is identified as a material containing less than one percent asbestos.
Materials testing less than one percent asbestos are not regulated under the EPA handling, removal and disposal requirements. However, OSHA regulations (29 CFR, 1920.1001, 29 CFR,
1926.1101 and interpretations) require that the material be handled at all times by personnel with appropriate asbestos training and that an OSHA defined competent person select appropriate work procedures and engineering control strategies during removal/handling operations.
All other suspect materials identified and sampled in the 1st Floor tested negative for asbestos.
See the "Materials Which Tested Negative for Asbestos" section of this report.
Between the dates of September 6 and September 22, 2006, PBS Engineering and Environmental performed a comprehensive asbestos and limited lead-based paint survey of the Clatsop County Courthouse located at 749 Commercial Street in Astoria, Oregon. Samples of accessible suspect asbestos-containing materials (ACM) were collected and submitted under chain of custody to Lab/Cor, Inc. of Portland for polarized light microscopy (PLM) asbestos analysis. Representative paint chip samples were collected and submitted under chain of custody to RJ Lee Group, Inc. of San Leandro, CA. The following is a summary of our findings.
1.6
Astoria, OR 97103 749 Commercial StreetAsbestos and Limited Lead- Based Paint Survey
Report
A total of 20 representative paint coatings were collected from interior and exterior building components. Sample locations were focused on areas designated for up-coming renovation work. Results varied. The lead paint sample number, location, component, substrate, color, condition and laboratory result are as follows:
2001; Basement; court staff manager office; wall; gypsum; white; good; <128 ppm.
2002; Basement; server room; wall; gypsuml; cream; good; <143 ppm.
2003; Basement; server room; wall; brick; cream; good; <102 ppm.
2004; Basement; boiler room; wall; brick; white; poor; <72.5 ppm.
2005; Basement; server room vestibule; column; wood; green; fair; 132 ppm.
2006; Basement; court staff office; vault door; metal; yellow; good; 33,500 ppm.
2007; Basement; court staff office; wall; gypsum; off-white; good; <217 ppm 2008; 1st Floor; SW conference room; wall; plaster; white over green; good; 127 ppm.
2009; 1st Floor; central service office; wall; plaster; white over tan; good; 165,000 ppm.
2010; 1st Floor; central services office; wall; gypsum; white; good; <105 ppm.
2011; 1st Floor; court clerk; office north of break room; wall; plaster; white over tan; good; <84.4 ppm.
2012; 1st Floor; court clerk; open office area; wall; plaster; white over tan;
2013; 1st Floor; juvenile conference room; wall; plaster; green/tan; good.
2014; 1st Floor; juvenile conference room east storage rooml; wall; plaster; white; good.
2ND FLOOR
Mixed results were obtained for glued-on ceiling and wall tiles located in the Courtroom walls and ceiling. The results are mixed with the highest concentration resulting at less than one percent. Until further sampling of this material is performed, it is identified as a material containing less than one percent asbestos.
Materials testing less than one percent asbestos are not regulated under the EPA handling, removal and disposal requirements. However, OSHA regulations (29 CFR, 1920.1001, 29 CFR,
1926.1101 and interpretations) require that the material be handled at all times by personnel with appropriate asbestos training and that an OSHA defined competent person select appropriate work procedures and engineering control strategies during removal/handling operations.
All other suspect materials identified and sampled in the 2nd Floor tested negative for asbestos.
See the "Materials Which Tested Negative for Asbestos" section of this report.
ATTIC
There were no observed suspect ACM's in the attic space.
ROOF
All samples collected of the built-up roofing and associated sublayers tested negative for asbestos.
LEAD-BASED PAINT
1.7
Astoria, OR 97103 749 Commercial StreetAsbestos and Limited Lead- Based Paint Survey
Report
2015; 1st Floor; west storage room; wall; plaster; green/tan; good.
2016; 1st Floor; storage room west of the juvenile conference room; wall; plaster; green/tan; good.
2017; 2nd Floor; juvenile department; breakroom; wall; plaster; white/green; good.
2018; 2nd Floor; juvenile department entrance; wall; wood; white/green; good.
2019; 2nd Floor; main corridor; ceiling; plaster; white/tan; good.
2020; Exterior; window outside 1st floor SW conference room; window frame; wood; maroon, good.
Laboratory analysis of these samples produced results ranging from below the limit of detection to 165,000 parts per million (ppm). There are several definitions of "lead-based paint." For consumer products, it is 0.06% or 600 ppm. The Department of Housing and Urban Development (HUD) defines lead-based paint as that which contains 0.5% or 5,000 ppm. Under OSHA, any amount of lead triggers the OSHA Lead in Construction Standard.
REGULATORY ISSUES (LEAD-BASED PAINT)
Oregon OSHA adopted the federal OSHA lead in construction standard (29 CFR 1926.62) in November of 1993 under OAR 437 Division 3 1926.62 The OR-OSHA standards outline worker exposure limits, personal protection requirements, and employer responsibility for exposure assessment, training, housekeeping and recordkeeping. OSHA's lead standard applies to all work where employees may be exposed to lead in construction, alteration, or repair. This includes demolition and/or renovation of structures where lead-containing materials are present.
Disposal of building demolition waste coated with lead-based paint will generally not require a hazardous waste determinations (i.e., TCLP testing) if demolition debris is disposed of at a solid waste landfill that is permitted by DEQ and which meets the current design standards for municipal solid waste disposal facilities of 40 CFR Part 258.
Reference the DEQ Hazardous waste reduction policy and follow all requirements under the Oregon DEQ, Management of Building Demolition Waste, 97-002 for proper disposal of lead-based painted demolition waste.
1.8
Bulk Sample Inventory Asbestos/Lead Survey
Code Material Location Lab Basement; judge chambers' corridor; beige/olive tile under carpet
Lab Cor 19786.000-0101 Vinyl Floor Tile/Mastic (01)
4% Chrysotile (Vinyl, beige) Analysis:
No Asbestos Detected (Mastic, brown) No Asbestos Detected (Mastic, black)
Basement; server room above LCT Lab Cor
19786.000-0102 Mag Pipe Insulation 8% Chrysotile (Fibrous powder, off white) Analysis:
Basement; SW corner of courtroom; brown tile under carpet Lab Cor
19786.000-0103 Vinyl Floor Tile/Mastic (03) 4% Chrysotile (Vinyl, brown) Analysis:
No Asbestos Detected (Mastic, yellow)
Basement; men's room; teal mosaic pattern Lab Cor
19786.000-0104 Sheet Floor Covering (01) No Asbestos Detected (Vinyl, grey) Analysis:
No Asbestos Detected (Mastic, grey) No Asbestos Detected (Fibrous material, grey)
Basement; break room; grey square pattern Lab Cor
19786.000-0105 Sheet Floor Covering (02)
No Asbestos Detected (Mastic, tan)
Basement; server room brown mosaic pattern Lab Cor
19786.000-0106 Sheet Floor Covering (03) No Asbestos Detected (Vinyl, brown) Analysis:
No Asbestos Detected (Fibrous material, tan)
Basement; judge restroom; grey mosaic pattern Lab Cor
19786.000-0107 Sheet Floor Covering (04)
Basement; main corridor at S entrance; residual floor mastic; black Lab Cor
19786.000-0108 Mastic No Asbestos Detected (Mastic, black) Analysis:
2.1
Project #: 19786.000 Task 0001
Basement; main corridor
Lab Cor 19786.000-0109 Lay-in Ceiling Tile (01)
No Asbestos Detected (Compressed fibers, tan) Analysis:
Basement; main corridor; plaster ceiling above LCT
19786.000-0110 Wall and Ceiling Plaster (01) No Asbestos Detected (Cementitious, grey) Analysis:
Basement; main corridor; plaster ceiling above LCT
19786.000-0111 Wall and Ceiling Plaster (01)
Basement; stair to 1st floor; wall
19786.000-0112 Wall and Ceiling Plaster (02)
Basement; stair to 1st floor; wall
19786.000-0113 Wall and Ceiling Plaster (02)
Basement; main corridor; wall outside court staff
19786.000-0114 Gypsum Wallboard/Joint Compd.
No Asbestos Detected (Compacted material, off white)
Analysis:
Basement; law library; witness room; wall
19786.000-0115 Gypsum Wallboard/Joint Compd.
No Asbestos Detected (Compacted material, white)
2.2
1st floor; SW vault; north entrnace; white w/ blue diamond pattern
Lab Cor 19786.000-0116 Sheet Floor Covering (05)
No Asbestos Detected (Vinyl, off white) Analysis:
1st floor; court clerk vault; brown herringbone pattern (45 degrees) Lab Cor
19786.000-0117 Sheet Floor Covering (06) No Asbestos Detected (Vinyl, red) Analysis:
1st floor; west storage room; beige/olive tile w/ black mastic; under carpet
19786.000-0118 Vinyl Floor Tile/Mastic (04) 3% Chrysotile (Vinyl, tan) Analysis:
1st floor; juvenile conference room east storage room; brown w/ black mastic; under carpet
Lab Cor
19786.000-0119 Sheet Floor Covering (09)
No Asbestos Detected (Mastic, tan) Analysis:
No Asbestos Detected (Fibrous tar, black) No Asbestos Detected (Vinyl, red)
1st floor; court clerk office adj to breakroom; 9" beige tile under carpet Lab Cor
19786.000-0120 Vinyl Floor Tile/Mastic (06) No Asbestos Detected (Vinyl, tan) Analysis:
1st floor; NW storage room; 2x4 random fissure w/ pin perf Lab Cor
19786.000-0121 Lay-in Ceiling Tile (02) No Asbestos Detected (Compressed fibers, grey)
1st floor; court clerk break room; 2x4 pockmark pattern
19786.000-0122 Lay-in Ceiling Tile (03) No Asbestos Detected (Compressed fibers, 2.3
1st floor; west storage room; 1x1 peg hole pattern
Lab Cor 19786.000-0123 Stapled-on Ceiling Tile (01)
No Asbestos Detected (Compressed fibers, tan/white)
1st floor; juvenile conference room; 1x1 heavy textured above LCT
19786.000-0124 Glued-on Ceiling Tiles (01) No Asbestos Detected (Compacted material, tan)
1st floor; west storage room; ceiling above LCT Lab Cor
19786.000-0125 Wall and Ceiling Plaster (02) No Asbestos Detected (Cementitious, white) Analysis:
No Asbestos Detected (Cementitious, grey)
1st floor; SW conference room; ceiling above LCT Lab Cor
19786.000-0126 Wall and Ceiling Plaster (02)
No Asbestos Detected (Powder, grey)
1st floor; west storage room; west wall Lab Cor
19786.000-0127 Wall and Ceiling Plaster (02) No Asbestos Detected (Powder, grey) Analysis:
1st floor; west storage room; near west entrance; north wall
19786.000-0128 Wall and Ceiling Plaster (02)
No Asbestos Detected (Powder, grey)
1st floor; juvenile conference room; east wall
Lab Cor
19786.000-0129 Gypsum Wallboard/Joint Compd.
No Asbestos Detected (Compacted powder, No Asbestos Detected (Compacted material, tan)
2.4
1st floor; central services; south office; north wall
Lab Cor
19786.000-0130 Gypsum Wallboard/Joint Compd.
No Asbestos Detected (Compacted material, 2nd floor; judge chambers restroom; beige w/ line pattern
19786.000-0131 Sheet Floor Covering (07) No Asbestos Detected (Vinyl, tan) Analysis:
2nd floor; jury room restroom; red sand pattern Lab Cor
19786.000-0132 Sheet Floor Covering (08) No Asbestos Detected (Vinyl, red) Analysis:
2nd floor; courtroom corridor; 2x4 random fissure w/ pin perf Lab Cor
19786.000-0133 Lay-in Ceiling Tile (04) No Asbestos Detected (Compressed fibers, tan) Analysis:
2nd floor; DA office; file room; 2x4 big fissure
19786.000-0134 Lay-in Ceiling Tile (05) No Asbestos Detected (Compressed fibers, tan/white)
2nd floor; assistant DA offices; 2x4 textured w/ pin perf
19786.000-0135 Lay-in Ceiling Tile (06) No Asbestos Detected (Compressed fibers, 2nd floor; courtroom; south wall
19786.000-0136 Glued-on Ceiling Tiles (02) Trace Chrysotile (Loose particulate, brown) Analysis:
2.5
2nd floor; courtoom hallway; ceiling
Lab Cor 19786.000-0137 Wall and Ceiling Plaster (02)
No Asbestos Detected (Homogenous) Analysis:
2nd floor; assist DA office area; ceiling
19786.000-0138 Wall and Ceiling Plaster (02)
No Asbestos Detected (Cementitious, grey)
2nd floor; courthouse hallway; wall Lab Cor
19786.000-0139 Wall and Ceiling Plaster (02) No Asbestos Detected (Powder, grey) Analysis:
2nd floor; juvenile dept; NW office; east wall
19786.000-0141 Gypsum Wallboard/Joint Compd.
No Asbestos Detected (Compacted powder, off
No Asbestos Detected (Compacted material, 2nd floor; courtroom hallway; west wall Lab Cor
19786.000-0142 Textured Ceiling Material No Asbestos Detected (Compacted material, white/ green)
2nd floor; courtroom hallway; north wall
19786.000-0143 Textured Ceiling Material No Asbestos Detected (Compacted material, white/ green)
Roof; NE corner; field
19786.000-0144 Built-up Roofing (01) No Asbestos Detected (Rocky fibrous tar, black)
2.6
Roof; center; field
Lab Cor 19786.000-0145 Built-up Roofing (01)
No Asbestos Detected (Rocky fibrous tar, Roof; south; parapet Lab Cor
19786.000-0146 Built-up Roofing (02) No Asbestos Detected (Rocky fibrous tar, Roof; 2nd layer of roofing; under 1st layer plywood substrate
19786.000-0147 Built-up Roofing (03) No Asbestos Detected (Fibrous tar, black) Analysis:
1st floor; central services vault; brown marble
19786.000-0148 Sheet Floor Covering (10) No Asbestos Detected (Vinyl, brown) Analysis:
2.7
Lead Sample Inventory Asbestos/Lead Survey
Code LocationMaterial Analysis Lab
PAINT
Basement; court staff manager office; wall; gypsum;
off white; good
R.J. Lee GroupLB19786.000-2001 Paint <128 ppm
Basement; server room; wall; gypsum; cream; good R.J. Lee GroupLB19786.000-2002 Paint <143 ppm
Basement; server room; wall; brick; cream; good R.J. Lee GroupLB19786.000-2003 Paint <102 ppm
Basement; boiler room; wall; brick; white; poor R.J. Lee GroupLB19786.000-2004 Paint <72.5 ppm
Basement; server room vestible; column; wood;
green; fair
R.J. Lee GroupLB19786.000-2005 Paint 132 ppm
Basement; court staff room vault; door; door; metal;
yellow; good
R.J. Lee GroupLB19786.000-2006 Paint 33,500 ppm
Basement; court staff office; wall; gypsum; off white;
good
R.J. Lee GroupLB19786.000-2007 Paint <217 ppm
1st floor; SW conference room; wall; plaster;
white/green; good
R.J. Lee GroupLB19786.000-2008 Paint 127 ppm
1st floor; central services; wall; plaster; white/tan;
good
R.J. Lee GroupLB19786.000-2009 Paint 165,000 ppm
1st floor; central services; wall; gypsum; white; good R.J. Lee GroupLB19786.000-2010 Paint <105 ppm
1st floor; court clerk; office north of breakroom; wall;
plaster; white/tan; good
R.J. Lee GroupLB19786.000-2011 Paint <84.4 ppm
1st floor; court clerk; open office area; wall; plaster;
white/tan; good
R.J. Lee GroupLB19786.000-2012 Paint 141,000 ppm
1st floor; juvenile conference room; wall; plaster;
green/tan; good
R.J. Lee GroupLB19786.000-2013 Paint 3190 ppm
1st floor; juvenile conference room east storage room; wall; plaster; white; good
R.J. Lee GroupLB19786.000-2014 Paint 102 ppm
1st floor; west storage room; wall; plaster; green/tan;
good
R.J. Lee GroupLB19786.000-2015 Paint 1520 ppm
1st floor; storage room west of the juvenile conference room; wall; plaster; green/tan; good
R.J. Lee GroupLB19786.000-2016 Paint 4540 ppm
2nd floor; juvenile dept; breakroom; wall; plaster;
white/green; good
R.J. Lee GroupLB19786.000-2017 Paint 226 ppm
2nd floor; juvenille department entrance; wall; wood;
white/green; good
R.J. Lee GroupLB19786.000-2018 Paint <128 ppm
2nd floor; main corridor; ceiling; plaster; white/tan;
good
R.J. Lee GroupLB19786.000-2019 Paint 510 ppm
Exterior; 1st floor; window outside SW conference room; window frame; wood; maroon; good
R.J. Lee GroupLB19786.000-2020 Paint 110,000 ppm
File details come from the government source that posted it. Updated .