D

G

F

N

M

S

R

C

B

A E

L

K

J

P

O

X

W

U

V

T

H

I

OUTSIDE DIAMETER

OPENING

OUTSIDE BLADE DAMPER

PLATE

PRELIMINARY

POLYVINYL CHLORIDE

POUNDS PER SQUARE INCH

POINT OF VERTICAL CURVE,

REFERENCE, REFER TO

REINFORCEMENT

REVISION

ROOM

SCHEDULE

SECTION

SHEET

POUNDS PER SQUARE FOOT

RADIUS, RISER, RUBBER SHEATH

SPLITTER DAMPER

CKT

CLG

CMU

COL

CONC

CND,C

CONN

CONST

COND

D

L

C

DEPTH, DEEP, DEGREE OF CURVATURE

GB

GW

GPM

GR

GRD

CONCRETE MASONRY UNITS

CONCRETE

CONDUCTOR

CONNECTION

CONSTRUCTION

COLUMN

CONDUIT

CENTERLINE

CEILING

CIRCUIT

GALV

GA, G

FT

FL

FIN

FFE

GYPSUM BOARD

GALLONS PER MINUTE

GROUND WATER

GRADE

GROUND

NTS

NO

NIC

FLOOR, FLASHING

GAGE

FOOT, FEET

GALVANIZED

FINISHED FLOOR ELEVATION

FINISH

N, NW

MISC

MTD

MECH

MIN

MAX

LED

NOT IN CONTRACT

NUMBER

NOT TO SCALE

SHT

NORTH, NEW

MISCELLANEOUS

MOUNTED

MAXIMUM

MECHANICAL

MINIMUM

LIGHTING EMITING DIODE

RM

SD

REINF

REV

SCH, SCHED

SECT

R

RE, REF

PSF

DET, DTL

EL, ELEV

EXIST, EX, E

LIST OF ABBREVIATIONS

A/C

AFF

AP

ARR

ARCH

ALT

A.B.I.

AL, ALUM

AMP,A

APPROX

BLDG, B

CC,CTC

B, BOT

AWG

BD

BUILDING

CENTER TO CENTER

BOARD

ALUMINUM

ARRESTOR

ALTERNATE

ACCESS PANEL

APPROXIMATE

ARCHITECTURAL

ABOVE FINISH FLOOR

AMERICAN WIRE GAGE

BOTTOM

AMPERE

EW

ELEC

EMT

D PNL

DWG

EA

DN

D, DIAM.

DIM

ACOUSTICAL BATT INSULATION

AIR CONDITIONING

ELECTRICAL METALLIC TUBING

ELECTRIC, ELECTRICAL

EACH WAY

EXISTING

ELEVATION

DISTRIBUTION PANEL

EACH

DRAWING

DIAMETER

DIMENSION

DOWN

KW

L

LBS

KV

KVA

JB

DETAIL

KILOVOLT-AMPERE

LENGTH, LENGTH OF CURVE

KILOVOLT

KILOWATT

POUNDS

JUNCTION BOX

PL

PSI

PRELIM

PVC

OD

OBD

OPNG

UNDERGROUND

TRANSFORMER

VENT, VOLT, VALVE

VITRIFIED CLAY PIPE

WATERPROOF, WEATHERPROOF

ANGULAR

WIDTH, WASTE, WATER, WATT, WEST

XFMR

WT WEIGHT

VERT

W

WP

W/

VCP

V

UG

TON

WITH

VERTICAL

TONELATE

SPECIFICATION

STRUCTURE, STRUCTURAL

STAINLESS STEEL

TOP, TANGENT

THREE POLE

TUBULAR STEELTS

3/P

STRUCT

STD

T

SW

STL

SQ

SS

STANDARD

STEEL

SWITCH

SQUARE

SPEC

BW BOTH WAY

CFM CUBIC FEET PER MINUTE

NOTE: SOME ABBREVIATIONS LISTED ARE NOT CONTAINED IN THESE DRAWINGS

EMB

EMBBEDED

EF

EACH FACE

ETC ETCETERA

C7 CIRCUIT NUMBER

FD

FLEXIBLE DUCT

FDB

FARENHEIT DRY BULB

FWB

FARENHEIT WET BULB

H, HGT, HT

HEX HEXAGONAL

HEIGHT

IN

ID INSIDE DIAMETER, INSIDE DIMENSION

INCH

AT

NUMBER, POUND

Ø

DIAMETER

MD MANUAL DAMPER

MBH MEGA BRITISH HOUR

GI

GALVANIZED IRON

IN C.W. INCH COLD WATER

LT LIGHT

AND

3W

THREE WAYS

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

90°

ANGLE DEGREE

RATED LOAD AMPERERLA

RETURN REGISTERRR

RETURN GRILLERG

ROOF TOP UNITRTU

HP HORSEPOWER

F

FARENHEIT

STO STORAGE

TYP TYPICAL

P

A

T

R

IO

T

B

L V

D

C A

L A

B A

S H

S T

F L A

M

B O

Y A

N

S T

H

O

W

Z

E

R

I V

E

ISABELA STREET

D

E

P

O

T

R

D

F

I

R

E

L

A

N

E

M

E

M

O

R

I

A

L

I

V

E

P

A

T

R

I

O

T

B

V

D

R

D

P

A

T

R

IO

T

B

L

V

D

V

I C

T

O

R

Y

D

R

C O

L U

M B

U S

SERVICE

D A

V I D

S

N

P

A

T

R

I

V

D

D

O

U

B

G

V

E

D

O

U

B

G

E

N

U

E

D

O

U

B

G

E

N

U

E

G

R

A

S

S E

R V

I C

E

R

D

S

E

R

V

I

C

E

R

D

S

O

U

T

H

S E

R V

I C

E R

D

D

E

P

O

T

R

D

S

O

U

H

R

M

I

N

N

O

R

T

H

T

E

R

M

IN

A

L

R

D

S O

U

R

M I N

COCONUT GROVE

N A

Y

W

Y

Driving Range

Golf

C o u r s e

R

D

R

E

S

E

R

V

A

T

I

U

N

D

A

R

Y

R

E

S

E

R

V

A

T

I

U

N

D

A

R

Y

P L

A Y

IN

G

F

IE

L D

X

G

U

A

Y

A

C

S E

A G

R A

P

T

O

T

O

D

A

V

I

W

H

I

T

N

H

E

N

G

A

T

E

R

D

P A

T R

IO

T B

L V

D

SO

UTH TERM

INAL RD.

X

X

X

X

X

X

X

X

X

X

X

X

P

E

R

I

M

E

T

C

O

L U

M

B

U

S

S

T

P

E

R

I

M

E

T

E

R

R

D

S

O

U

T

E

R D

R

E

S

E

R

V

A

T

I

U

N

D

A

R

Y

R

E

S

E

R

V

A

T

I

U

N

D

A

R

Y

R

E

S

E

R

V

A

T

I

U

N

D

A

R

Y

T

O

S

O

U

R

M

I

N

X

XX

X

H

H

H

H

H

H

H

BORINQUENEER RD.

S

A

N

M

I

N

R

R

A

C

K

H

E

N

R

R

A

C

A

I

B

O

N

I

R

R

A

C

A

G

U

A

D

I

L

R

R

A

C

M

A

Y

A

G

U

E

Z

N

O

R

R

M

I N

F

R

E

E

D

O

M

T

E

W

A

Y

W

H

I

T

N

H

H

H

H

H

H

C

I

T

I

Z

E

N

S

O

L

D

I

W

Y

C

A

L

A

B

A

A

U

S

U

HOWZE DRIVE

P

E

R

I M

E

T

R A

I N

T R

S

E

R

V

I

C

E

P

E

R

I

M

E

T

Golf Course

COURT NO. 1

COURT NO. 2

D

O

U

B

G

E

N

U

E x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

C O

N S

T I T

U T

I O

N

A

V E

F

R

E

E

D

O

M

'S

T

E

W

A

Y

P

PLAY

GROUND

P

L

A

Y

G

R

O

U

N

D

P

P N

P

N

P

N

S T

PRNG

REDINESS CENTER

S A

N T

IA

G

O S

T

SANTIAGO ST.

130.8849

BORINQUENEER GATE

ELEMENTARY SCHOOL

HIGH SCHOOL

NEW DPW

FACILITY

MAXIE WILLIAMS

JR FIELD

Softball Field

GOLF COURSE

Basketball

Aqua Park

L A K E

MIDDLE SCHOOL

1,000,000 GAL.

WATER TANK

20 MVA SUBSTATION

LAS COLINAS

ELEMENTARY SCHOOL

NEW ANTILLES

Basketball Playground

Softball

Softball

Court

USAR

CENTER

Baseball

Picnic

FAC NO. 7

Picnic

PX

79 80

68 66

807812

218 220

396366

1234 1231

829 831

Area

Maxie Williams Parking

10771075

Court

COMMISSARY AND PX

WASH

RACK

820821

01094

PN218

PN202

PN1140

PN376

PN192

353 357

354 356

PN021

PN1339

PN404

PN404

10741138

1134 1132

1152 1154

PN354

PN355

Tennis

Tennis

F1094

10291037

105610571058

P1029

PLAY COURT

RW

Ply

PN218

PN224

PN566 PN152

P1068

PN239

P

PN025

PN148

P N

PN148

PN183 PN292

PN

PN152

01003

Area

PN614

PN363

Ply 006

P N

Skate Park

Ply 01 Ply 02Ply 04

Ply 05

Ply 03

PN

PN353

236241

PN348

328PN1300

PN

PN067

PN399

RT 039

WIND TURBINE 2

WIND TURBINE 1

CONTRACTOR 'S STAGING AREA

FD TRAINING AREA

AAFES CONTAINER 'S STORAGE SITE

500,000 GAL.

WATER TANK

(VACANT)

Soldiers Plaza

NEW CDC YC

Aparatus Bldg.

R

O

P

DE DIEGO EXPRESSWAY ( ROAD NO PR-28 )

C

T

A

N

O

R

O

A

D

N

O

P

R

-1

J

O

F

T

Z

G

E

R

A

N

N

E

E

F

R

A

N

K

L

R

O

O

S

E

V

E

E

T

O

H

A

T

O

R

E

Y

Y

A

M

O

N

B-7

B-1

B-9

B-5

B-2

B-6

B-8

B-10

B-11

B-3

B-4

B

B B

PUNTA BORINQUEN

(FORMER RAMEY U.S. AIR FORCE BASE)

SCALE IN MILEC A R I B B E A N S E A

P U E R T O R I C O

SALINAS

TRAING AREA

N

5 10

A T L A N T I C O C E A N

FORT BUCHANAN

SAN JUAN

U. S. NAVAL STATION

ROOSEVELT ROADS

DPW ENGINEERING DIVISION

RECOMMENDED APPROVAL:

ANIBAL NEGRON

DIRECTOR OF PUBLIC WORKS

LUIS E. TORRES

ENGINEERING DIVISION CHIEF

PROJECT TEAM

PROJECT MANAGER

CIVIL / ARCH. / DESIGN DEVELOPMENT

MECHANICAL DESIGN

ELECTRICAL DESIGN

GOV REP

REVISIONS

REV. NO. DATE APPD. BY

SCALE: N.T.S.

T-1

OF

DRAWING #:DPW-010

PROJECT #: 010

IJO:

DATE: APRIL/2022

SHEET TITLE NAME

PROJECT NAME

FT. BUCHANAN, PUERTO RICO

DAVIS STREET

ENVIRONMENTAL DIVISION (DPW)

ACTIVITY

O&M DIVISION (DPW)

MASTER PLANNING (DPW)

ENERGY MANAGER (DPW)

PHYSICAL SECURITY (DES)

POLICE SERVICES (DES)

SAFETY OFFICE

FIRE DEPARTMENT (DES)

FORCE PROTECTION (DPTMS)

NETWORK ENTERPRISE CENTER

(NEC)

TENANT

PRINT NAME INITIALS DATE

DEPARTMENT OF THE ARMY

GENERAL REPAIRS, BUILDING # 223

FORT BUCHANAN, PUERTO RICO

INDEX OF DRAWINGS

DRAWING NO.

T-1

D-1

A-1

TITLE

TITLE SHEET, LOCATION SITE MAPS & DRAWING INDEX

DEMOLITION WORKS SHOWER ROOM #1

PROJECT SITE LOCATION

FORT BUCHANAN SITE MAP

LOCATION MAP

GENERAL REPAIRS

BUILDING 223

ED-1 ELECTRICAL DEMOLITION PLAN

EI-1 ELECTRICAL INSTALLATION PLAN

NEW WORKS SHOWER ROOM #1

F.ZAYAS.

F.ZAYAS.

C.IRIZARRY.

A.GONZALEZ.

SHEET NO.

Site Location

TITLE SHEET, LOCATION SITE

MAPS & DRAWING INDEX

A-2

NEW WORKS SHOWER ROOM #2

APPROVED BY:

X

D

O

U

B

G

E

N

U

E

S

O

U

T

H

D

A

V

W

H

I

T

N

H

E

N

G

A

T

E

R

D

H

H

H

H

H

H

H

F

R

E

E

D

O

M

T

E

W

A

Y

W

H

I

T

N

H

H

H

H

H

H

F

R

E

E

D

O

M

T

E

W

A

Y

Basketball

218 220

PN218

PN202

PN192

PN355

PN218

PN224

PN239

PN183 PN292

PN

PN

236241

Site Location

Staging Area Location

D-2 DEMOLITION WORKS SHOWER ROOM #24

SI-1 NEW WORKS LOCATION PLAN AND NEW WATER COOLER FOUNTAIN INSTALLATION DETAILS2

AutoCAD SHX Text

EL

AutoCAD SHX Text

TORO

AutoCAD SHX Text

CREEK

AutoCAD SHX Text

BAILEY RD.

AutoCAD SHX Text Playground

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CERRO

AutoCAD SHX Text

DOÑA JUANA ST.

AutoCAD SHX Text

CERRO PUNTA ST.

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text x

AutoCAD SHX Text

PUNTA ST.

AutoCAD SHX Text L A K E

AutoCAD SHX Text

SPC VEGA GATE

AutoCAD SHX Text

EL

AutoCAD SHX Text

TORO

AutoCAD SHX Text

CREEK

NEW

" WATER SUPPLY COPPER PIPE

FOR ICE MAKER & DRINKING

FOUNTAIN (SEE NOTE 9)

NEW BALL GATE

VALVE CONNECTED

TO THE EXISTING

COPPER PIPE

DPW ENGINEERING DIVISION

ANIBAL NEGRON

DIRECTOR OF PUBLIC WORKS

LUIS E. TORRES

ENGINEERING DIVISION CHIEF

PROJECT MANAGER

MECHANICAL DESIGN

ELECTRICAL DESIGN

GOVERNMENT REPRESENTATIVE:

REVISIONS

REV. NO. DATE APPD. BY

DRAWING #: DPW-010

PROJECT #: 010

IJO:

DATE: APRIL, 2022

SHEET TITLE NAME

PROJECT NAME

FT. BUCHANAN, PUERTO RICO

GENERAL

REPAIRS

BUILDING 223

CIVIL / ARCH. / DESIGN DEVELOPMENT

SCALE: AS SHOWN

OF

F.ZAYAS.

F.ZAYAS.

X

A.GONZALEZ.

C.IRIZARRY.

RECOMMENDED APPROVAL:

APPROVED BY:

EE-1 IS-1

NEW WORKS BUILDING NOTES:

THE BUILDING SHALL KEEP IN OPERATION, CONTRACTOR SHALL PREPARE THE

CONSTRUCTION PROGRESS SCHEDULE IN COORDINATION WITH C.O.R. & TENANT.

NEW WALL MOUNTED WATER COOLER FOUNTAIN.

THE DESIGNED AREA FOR INSTALLATION OF TEMPORARY WAREHOUSE TRAILER

SHALL BE AT CONTRACTORS STAGING AREA, SEE PROJECT SITE LOCATION MAP.

3/16" = 1'-0"

BUILDING EXTERIOR ELEVATION EE-1

SHADE AREA IDENTIFIES SUNKEN FLOOR SLAB TO BE REPAIR WITH

SELF-LEVELING CONCRETE PRODUCT OVER EXISTING VINYL TILES.

NEW LOCATION OF EXISTING ICE MACHINE TO INSTALL NEW DRINKING FOUNTAIN.

EXISTING

" PVC PIPE SHALL BE SUBSTITUTE BY

" COPPER PIPE ATTACHED TO

WALL WITH S-STRUT CLAMP (SEE ELEVATION EE-1 FOR REFERENCE).

10 NEW WATER FILTER SYSTEM WITH TWO-STEP FILTRATION SYSTEM WITH

SEDIMENT FILTER CARTRIDGE & PREMIUM FILTER CARTRIDGE, 2.5 GPM FLOW

RATE, KDF MEDIA PREVENT LIME SCALE & BACTERIA GROWTH WHEN FILTER IS

NOT IN USE. THE NEW FILTER SYSTEM SHALL SUPPLY WATER TO EXISTING ICE

MAKER AND NEW DRINKING WATER FOUNTAIN WITH TWO

" DIA. X 5'-O"

STAINLESS STEEL WATER HOSE.

3/16" = 1'-0"

BUILDING INTERIOR SECTION IS-1

NEW WORKS LOCATION PLAN

AND NEW WATER COOLER

FOUNTAIN INSTALLATION

DETAILS

3/16" = 1'-0"

ELEVATION REFERENCE PLAN

3/16" = 1'-0"

NEW WORKS LOCATION PLAN

EXISTING ICE MACHINE AND NEW DRINKING FOUNTAIN SHALL DRAINAGE TO THE OUT

SITE OF THE BUILDING IN 2" PVC PIPE AND DISCHARGE USED WATER, BELOW GROUND

LEVEL, TO THE EXISTING CONCRETE OPEN CHANNEL.

THE DETAILS AND INFORMATION PRESENTED HERE ARE CONCEPTUAL, THE

CONTRACTOR HAS TO VERIFY THE FINAL DISTANCES, ELEVATIONS AND LOCATIONS OF

THE EQUIPMENT. IN THE EVENT THAT THE CONTRACTOR FINDS ANY DISCREPANCIES,

THIS MATTER SHALL BE NOTIFIED IMMEDIATELY TO THE GOVERNMENT.

TO AVOID THE ENTRANCE OF SMALL ANIMALS TROUGH THE DISCHARGE PIPE,

CONTRACTOR SHALL INSTALL 2" SCREEN TERMINATION PVC MESH CAP.

SI-1

HATCH AREAS IDENTIFY

SUNKEN FLOOR TO REPAIR

6 FLOOR AREAS WITH NEW VINYL TILES OVER NEW CONCRETE SELF LEVELING AND

EXISTING VINYL TILES. INSTALL TRANSITION TILE REDUCER WHERE NEW VINYL TILES

FINISH AND EXISTING FLOORING CONTINUE.

6 6 6

AutoCAD SHX Text

BATHROOM #2

BATHROOM #1

DPW ENGINEERING DIVISION

ANIBAL NEGRON

DIRECTOR OF PUBLIC WORKS

LUIS E. TORRES

ENGINEERING DIVISION CHIEF

PROJECT MANAGER

MECHANICAL DESIGN

ELECTRICAL DESIGN

GOVERNMENT REPRESENTATIVE:

REVISIONS

REV. NO. DATE APPD. BY

DRAWING #: DPW-010

PROJECT #: 010

IJO:

DATE: APRIL, 2022

SHEET TITLE NAME

PROJECT NAME

FT. BUCHANAN, PUERTO RICO

GENERAL

REPAIRS

BUILDING 223

CIVIL / ARCH. / DESIGN DEVELOPMENT

SCALE: AS SHOWN

OF 8

F.ZAYAS.

F.ZAYAS.

X

A.GONZALEZ.

C.IRIZARRY.

RECOMMENDED APPROVAL:

APPROVED BY:8

D1 E1

E4

E3

E2

Floor Level 0' - 0"

Acoustic Ceiling Level 8' - 0"

10 11

Floor Level 0' - 0"

Acoustic Ceiling Level 8' - 0"

13 4

Floor Level 0' - 0"

Acoustic Ceiling Level 8' - 0"

Floor Level 0' - 0"

Acoustic Ceiling Level 8' - 0"

1/2" = 1'-0"

DEMOLITION FLOOR PLAN

BATHROOM 1

1/2" = 1'-0"

DEMOLITION CEILING PLAN

BATHROOM 1

1/2" = 1'-0"

EXSTING ELEVATION E3

1/2" = 1'-0"

EXISTING ELEVATION E1

1/2" = 1'-0"

EXISTING ELEVATION E2

1/2" = 1'-0"

EXISTING ELEVATION E4

DEMOLITION NOTES:

EXISTING ACOUSTIC CEILING TILE AND TEGULAR GRID TO BE REMOVED

EXISTING SUSPENDED GYPSUM CEILINGTO BE REMOVED

REMOVE POLISH WAX FINISH ON EXISTING RESILIENT VINYL FLOOR TO REMAIN

EXISTING 4" HIGH RUBBER COVE WALL BASE TO BE REMOVED

EXISTING GYPSUM BOARD WALL TO BE REMOVED

EXISTING EXHAUST FAN TO BE REMOVED

EXISTING SHOWER, STALL, RECEPTOR TO BE REMOVED

SHOWER FLOOR DRAIN & TOILET FLANGE TO BE REMOVED

EXISTING TOILETE TO BE REMOVED

EXISTING GRAB BARS TO BE REMOVED

EXISTING SEMI-RECESED TOWEL DISPENSER TO BE REMOVED

EXISTING TOILET TISSUE DISPENSER TO BE REMOVED AND STORAGE

LIQUID SOAP DISPENSER TO BE REMOVED AND STORAGE

EXISTING INTERIOR WOOD DOOR & FRAME TO BE REMOVED

EXISTING 2 X 4 CEILING LIGHTING FIXTURES TO BE REMOVED

DEMOLITION WORKS

SHOWER ROOM #1

EXISTING LAVATORY, WITH FAUCET, SHUTOFF VALVES, FLEXIBLE

CONNECTIONS AND DRAINAGE PIPE TO BE REMOVED

1/2" = 1'-0"

SUNKEN FLOOR AREA

D-1

REMOVE THE POLISH WAX FINISH ON VINYL TILES17

1717 17

BATHROOM #1

D2 E5

E8

E7

E6

D2 E5

E8

E7

E6

Floor Level 0' - 0"

Acoustic Ceiling Level 8' - 0"

Floor Level 0' - 0"

Acoustic Ceiling Level 8' - 0"

Floor Level 0' - 0"

Acoustic Ceiling Level 8' - 0"

Floor Level 0' - 0"

Acoustic Ceiling Level 8' - 0"

1 6

DPW ENGINEERING DIVISION

ANIBAL NEGRON

DIRECTOR OF PUBLIC WORKS

LUIS E. TORRES

ENGINEERING DIVISION CHIEF

PROJECT MANAGER

MECHANICAL DESIGN

ELECTRICAL DESIGN

GOVERNMENT REPRESENTATIVE:

REVISIONS

REV. NO. DATE APPD. BY

DRAWING #: DPW-010

PROJECT #: 010

IJO:

DATE: APRIL, 2022

SHEET TITLE NAME

PROJECT NAME

FT. BUCHANAN, PUERTO RICO

GENERAL

REPAIRS

BUILDING 223

CIVIL / ARCH. / DESIGN DEVELOPMENT

SCALE: AS SHOWN

OF 8

F.ZAYAS.

F.ZAYAS.

X

A.GONZALEZ.

C.IRIZARRY.

RECOMMENDED APPROVAL:

APPROVED BY:

1/2" = 1'-0"

DEMOLITION FLOOR PLAN

BATHROOM 2

1/2" = 1'-0"

DEMOLITION CEILING PLAN

BATHROOM 2

1/2" = 1'-0"

EXISTING ELEVATION E5

1/2" = 1'-0"

EXISTING ELEVATION E6

1/2" = 1'-0"

EXISTING ELEVATION E7

1/2" = 1'-0"

EXISTING ELEVATION E8

DEMOLITION NOTES:

EXISTING ACOUSTIC CEILING TILE AND TEGULAR GRID TO BE REMOVED

AND DISPOSE

EXISTING SUSPENDED GYPSUM CEILINGTO BE REMOVED

EXISTING RESILIENT VINYL FLOOR TO REMOVE THE WAX FINISH.

EXISTING 4" HIGH RUBBER COVE WALL BASE TO BE REMOVED

EXISTING GYPSUM BOARD WALL TO BE REMOVED

EXISTING EXHAUST FAN AND GRILL TO BE REMOVED

EXISTING SHOWER, STALL, RECEPTOR AND CURTAIN TO BE REMOVED

EXISTING TOILETE TO BE REMOVED

EXISTING LAVATORY, WITH FAUCET, SHUTOFF VALVES, FLEXIBLE

CONNECTIONS AND DRAINAGE PIPE TO BE REMOVED

EXISTING GRAB BARS TO BE REMOVED

EXISTING SEMI-RECESED TOWEL DISPENSER TO BE REMOVED

EXISTING TOILET TISSUE DISPENSER TO BE REMOVED

LIQUID SOAP DISPENSER TO BE REMOVED

EXISTING INTERIOR METAL DOOR & FRAME TO REMAIN

EXISTING SHOWER TOWER BAR TO BE REMOVED

DEMOLITION WORKS

SHOWER ROOM #2

SHOWER FLOOR DRAIN & TOILET FLANGE TO BE REMOVED

D-2

EXISTING 2 X 4 CEILING LIGHTING FIXTURES TO BE REMOVED17

EXISTING MIRROR TO BE REMOVED18

Floor Level

0' - 0"

Acoustic Ceiling

Level

8' - 0"

Floor Level

0' - 0"

Acoustic Ceiling

Level

8' - 0"

Floor Level

0' - 0"

Acoustic Ceiling

Level

8' - 0"

Floor Level

0' - 0"

Acoustic Ceiling

Level

8' - 0"

DPW ENGINEERING DIVISION

ANIBAL NEGRON

DIRECTOR OF PUBLIC WORKS

LUIS E. TORRES

ENGINEERING DIVISION CHIEF

PROJECT MANAGER

MECHANICAL DESIGN

ELECTRICAL DESIGN

GOVERNMENT REPRESENTATIVE:

REVISIONS

REV. NO. DATE APPD. BY

DRAWING #: DPW-010

PROJECT #: 010

IJO:

DATE: APRIL, 2022

SHEET TITLE NAME

PROJECT NAME

FT. BUCHANAN, PUERTO RICO

GENERAL

REPAIRS

BUILDING 223

CIVIL / ARCH. / DESIGN DEVELOPMENT

SCALE: AS SHOWN

OF

F.ZAYAS.

F.ZAYAS.

X

A.GONZALEZ.

C.IRIZARRY.

RECOMMENDED APPROVAL:

APPROVED BY:

A1

E4

E1

E2

E3

1/2" = 1'-0"

NEW FLOOR PLAN

BATHROOM 1

1/2" = 1'-0"

NEW ELEVATION E1

1/2" = 1'-0"

NEW ELEVATION E2

1/2" = 1'-0"

NEW ELEVATION E3

1/2" = 1'-0"

NEW ELEVATION E4

1/2" = 1'-0"

NEW REFLECTED CEILING PLAN

BATHROOM 1

NEW WORK NOTES (THIS SHEET ONLY):

NEW CERAMIC FLOOR TILES TO BE INSTALLED OVER NEW SELF LEVELING

CONCRETE TOPPING

NEW FIBERGLASS REINFORCED PANELS AND 6" HIGH CERAMIC TILE

COVE BASE

NEW EXHAUST FAN TO BE INSTALLED

NEW ELONGATED TOILET WITH MANUAL FLUSH VALVE AND DRAINAGE

FLANGE

NEW TWO WALL TOILET 48" X 36" & L-SHAPED SHOWER BAR 16' X 32" TO

BE INSTALLED

NEW SURFACE MOUNTED WASTE RECEPTACLE SIMILAR OR EQUAL TO

BRADLEY 344, 12 GALLON

NEW TWO ROLL TOILET TISSUE DISPENSER SIMILAR OR EQUAL TO GLOBAL

INDUSTRIAL WR640933

NEW METAL FRAME AND WOOD DOOR

NEW LAVATORY WITH FAUCET, SHUT-OFF VALVES, FLEXIBLE

CONNECTIONS, DRAINAGE PIPE & SINGLE CARRIER SIMILAR OR EQUAL

TO J.R. SMITH 0700E

NEW STAINLESS STEEL ANGLE FRAME FIXED-POSITION TILT MIRROR 24"X36"

NEW IMPACT RESISTANT PLASTIC SHELL SOAP DISPENSER TO BE INSTALLED

NEW TOILET SEAT COVER DISPENSER14

3/8" = 1'-0"

SUNKED FLOOR REPAIR PLAN

NEW VINYL FLOOR TILES TO BE INSTALLED OVER NEW SELF LEVELING

CONCRETE TOPPING AND EXISTING FLOORING

NEW 2 X 4 CEILING LIGHTING REFER TO SHEET EI -1

NEW RECESSED SHAMPOO AND SOAP NICHE.

NEW PAPER TOWEL DISPENSER SIMILAR OR EQUAL TO SAN JAMAR T950TBK

NEW 24" SURFACE MOUNTED SQUARE TOWEL BAR SIMILAR OR EQUAL TO

BOBRICK B6737-24

NEW ROUND SLIDING SHOWER ENCLOSURE WITH BASE SIMILAR OR

EQUAL TO PERIGOLD DREAMLINE DL-6152-01CLAND SHOWER FAUCET

SYSTEM WITH 8" SHOWER HEAD AND HAND SHOWER

NEW WORKS

SHOWER ROOM #1

A-1

NEW CEILING 2' x 2' TILES ON METAL GRID SYSTEM (SEE DETAILS ON

THIS SHEET)

NOT TO SCALE

2' X 2' ACOUSTIC CEILING DETAILS

19 20

NEW TILES REDUCER TO BE INSTALL AT THE END OF THE NEW VINYL TILES

(NEW VINYL TILES LIMIT)

AutoCAD SHX Text

BATHROOM #1

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

1. PROVIDE SPLAY BRACING @ HANGER WIRES OF ALL SUSP. ACOUSTICAL

AutoCAD SHX Text

CEILINGS NOT MORE THAN 12'-0" O.C. AND NOT MORE THAN 6'-0"

AutoCAD SHX Text

FROM ALL WALL AND PARTITIONS. (SUBMIT LAYOUT FOR APPROVAL).

AutoCAD SHX Text

2. SPLICES AND INTERSECTIONS OF RUNNERS SHALL BE ATTACHED

AutoCAD SHX Text

WITH MECHANICAL INTERLOCKING CONNECTORS SUCH AS POP RIVET,

AutoCAD SHX Text

SCREWS PINS PLATES WITH BENT TABS OR OTHER APPROVED CONNECTORS.

AutoCAD SHX Text

WALL TRIM

AutoCAD SHX Text

HANGER WIRE

AutoCAD SHX Text 2' x 2' x 5/8"

AutoCAD SHX Text

ACOUSTICAL

AutoCAD SHX Text

12 GA. VERTICAL HANGER

AutoCAD SHX Text

WIRES @ 4'-0" O.C.

AutoCAD SHX Text

SEISMIC LOCKING PIN

AutoCAD SHX Text

MAIN RUNNER

AutoCAD SHX Text

CROSS RUNNER

AutoCAD SHX Text

WIRE GA. 12, @ 4'-0"

AutoCAD SHX Text

CONT. HORIZ. STRUT

AutoCAD SHX Text

TO PREVENT SPREADING

AutoCAD SHX Text

OF RUNNERS

AutoCAD SHX Text

MAIN RUNNER

AutoCAD SHX Text

GALV. STEEL SPLAY

AutoCAD SHX Text

BRACE WIRE, GA. 12

AutoCAD SHX Text

CROSS RUNNER

AutoCAD SHX Text

SPLICE

AutoCAD SHX Text 45%%D

AutoCAD SHX Text 45%%D

AutoCAD SHX Text 45%%D

AutoCAD SHX Text 45%%D

AutoCAD SHX Text 2"

AutoCAD SHX Text

MAX

AutoCAD SHX Text

3. CROSS AND MAIN RUNNERS SHALL BE CORROSION RESISTANCE WHITE

AutoCAD SHX Text

BAKED ENAMEL PAINTED.

AutoCAD SHX Text

GALV. STEEL HANGER

AutoCAD SHX Text

O.C. EACH WAY

AutoCAD SHX Text

GALVANIZED STEEL

AutoCAD SHX Text

GALV. STEEL

AutoCAD SHX Text

GA. 12

AutoCAD SHX Text

4. GRID SYSTEM: 2'-0" x 2'-0" TYPE FOR MAIN AND CROSS RUNNERS.

AutoCAD SHX Text

TILES

AutoCAD SHX Text

5. INSTALL ACOUSTICAL CEILING SYSTEM AT 8'-0" ABOVE FINISHED FLOOR ELEVATION.

AutoCAD SHX Text

SHADOW MOLDING

AutoCAD SHX Text

6. INSTALL FACED FIBERGLASS ACOUSTIC BATT INSULATION OVER CEILING SYSTEM.

AutoCAD SHX Text

CONCRETE OR METAL

STRUCTURAL ROOF SLAB

A2 E5

E8

E7

E6

Floor Level

0' - 0"

Acoustic Ceiling

Level

8' - 0"

Floor Level

0' - 0"

Acoustic Ceiling

Level

8' - 0"

Floor Level

0' - 0"

Acoustic Ceiling

Level

8' - 0"

Floor Level

0' - 0"

Acoustic Ceiling

Level

8' - 0"

DPW ENGINEERING DIVISION

ANIBAL NEGRON

DIRECTOR OF PUBLIC WORKS

LUIS E. TORRES

ENGINEERING DIVISION CHIEF

PROJECT MANAGER

MECHANICAL DESIGN

ELECTRICAL DESIGN

GOVERNMENT REPRESENTATIVE:

REVISIONS

REV. NO. DATE APPD. BY

DRAWING #: DPW-010

PROJECT #: 010

IJO:

DATE: APRIL, 2022

SHEET TITLE NAME

PROJECT NAME

FT. BUCHANAN, PUERTO RICO

GENERAL

REPAIRS

BUILDING 223

CIVIL / ARCH. / DESIGN DEVELOPMENT

SCALE: AS SHOWN

OF

F.ZAYAS.

F.ZAYAS.

X

A.GONZALEZ.

C.IRIZARRY.

RECOMMENDED APPROVAL:

APPROVED BY:

1/2" = 1'-0"

NEW FLOOR PLAN

BATHROOM 2

1/2" = 1'-0"

ELEVATION E5

1/2" = 1'-0"

ELEVATION E6

1/2" = 1'-0"

ELEVATION E7

1/2" = 1'-0"

ELEVATION E8

NEW WORK NOTES (THIS SHEET ONLY):

NEW CEILING 2' x 2' TILES ON METAL GRID SYSTEM (SEE DETAILS ON THIS SHEET)

NEW CERAMIC FLOOR TILES TO BE INSTALLED OVER NEW SELF LEVELING

CONCRETE TOPPING

NEW FIBERGLASS REINFORCED PANELS AND 6" HIGH CERAMIC TILES COVE BASE

NEW EXHAUST FAN TO BE INSTALLED

NEW ROUND SLIDING SHOWER ENCLOSURE WITH BASE AND SHOWER FAUCET

SYSTEM WITH SHOWER HEAD AND HAND SHOWER

NEW TWO WALL BAR FOR TOILET 48" X 36" & L-SHAPED BAR FOR SHOWER

16' X 32" TO BE INSTALLED

NEW SURFACE MOUNTED WASTE RECEPTACLE TO BE INSTALLED

TOILET TISSUE DISPENSER PREVIOUSLY REMOVED AND STORED

EXISTING METAL DOOR FRAME TO BE PAINT, INSTALL NEW DOOR CLOSER AND WALL STOP.

NEW 2 X 4 CEILING LIGHTING TO BE INSTALLED, REFER TO SHEET EI-1.

NEW LAVATORY WITH FAUCET, P-TRAP, SHUT-OFF VALVES & FLEXIBLE CONNECTIONS.

NEW STAINLESS STEEL ANGLE FRAME H.C. TILT MIRROR (24"X36")

SOAP DISPENSER PREVIOUSLY REMOVED AND STORED

1/2" = 1'-0"

NEW REFLECTED CEILING PLAN

BATHROOM 2

NEW TOILET SEAT COVER DISPENSER

NEW 22" X 15" RECESSED SHOWER SHAMPOO SHELF SOAP DISH

PAPER TOWEL DISPENSER PREVIOUSLY REMOVED AND STORED

NEW SURFACE MOUNTED TOWEL BAR SIMILAR OR

EQUAL TO BOBRICK B6737X24

NEW ELONGATED TOILET WITH MANUAL FLUSH VALVE AND DRAINAGE FLANGE

NEW WORKS

SHOWER ROOM #2

A-2

NOT TO SCALE

2' X 2' ACOUSTICAL CEILING DETAILS

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

1. PROVIDE SPLAY BRACING @ HANGER WIRES OF ALL SUSP. ACOUSTICAL

AutoCAD SHX Text

CEILINGS NOT MORE THAN 12'-0" O.C. AND NOT MORE THAN 6'-0"

AutoCAD SHX Text

FROM ALL WALL AND PARTITIONS. (SUBMIT LAYOUT FOR APPROVAL).

AutoCAD SHX Text

2. SPLICES AND INTERSECTIONS OF RUNNERS SHALL BE ATTACHED

AutoCAD SHX Text

WITH MECHANICAL INTERLOCKING CONNECTORS SUCH AS POP RIVET,

AutoCAD SHX Text

SCREWS PINS PLATES WITH BENT TABS OR OTHER APPROVED CONNECTORS.

AutoCAD SHX Text

WALL TRIM

AutoCAD SHX Text

HANGER WIRE

AutoCAD SHX Text 2' x 2' x 5/8"

AutoCAD SHX Text

ACOUSTICAL

AutoCAD SHX Text

12 GA. VERTICAL HANGER

AutoCAD SHX Text

WIRES @ 4'-0" O.C.

AutoCAD SHX Text

SEISMIC LOCKING PIN

AutoCAD SHX Text

MAIN RUNNER

AutoCAD SHX Text

CROSS RUNNER

AutoCAD SHX Text

WIRE GA. 12, @ 4'-0"

AutoCAD SHX Text

CONT. HORIZ. STRUT

AutoCAD SHX Text

TO PREVENT SPREADING

AutoCAD SHX Text

OF RUNNERS

AutoCAD SHX Text

MAIN RUNNER

AutoCAD SHX Text

GALV. STEEL SPLAY

AutoCAD SHX Text

BRACE WIRE, GA. 12

AutoCAD SHX Text

CROSS RUNNER

AutoCAD SHX Text

SPLICE

AutoCAD SHX Text 45%%D

AutoCAD SHX Text 45%%D

AutoCAD SHX Text 45%%D

AutoCAD SHX Text 45%%D

AutoCAD SHX Text 2"

AutoCAD SHX Text

MAX

AutoCAD SHX Text

3. CROSS AND MAIN RUNNERS SHALL BE CORROSION RESISTANCE WHITE

AutoCAD SHX Text

BAKED ENAMEL PAINTED.

AutoCAD SHX Text

GALV. STEEL HANGER

AutoCAD SHX Text

O.C. EACH WAY

AutoCAD SHX Text

GALVANIZED STEEL

AutoCAD SHX Text

GALV. STEEL

AutoCAD SHX Text

GA. 12

AutoCAD SHX Text

4. GRID SYSTEM: 2'-0" x 2'-0" TYPE FOR MAIN AND CROSS RUNNERS.

AutoCAD SHX Text

TILES

AutoCAD SHX Text

5. INSTALL ACOUSTICAL CEILING SYSTEM AT 8'-0" ABOVE FINISHED FLOOR ELEVATION.

AutoCAD SHX Text

SHADOW MOLDING

AutoCAD SHX Text

6. INSTALL FACED FIBERGLASS ACOUSTIC BATT INSULATION OVER CEILING SYSTEM.

AutoCAD SHX Text

CONCRETE OR METAL

STRUCTURAL ROOF SLAB

DPW ENGINEERING DIVISION

ANIBAL NEGRON

DIRECTOR OF PUBLIC WORKS

LUIS E. TORRES

ENGINEERING DIVISION CHIEF

PROJECT MANAGER

MECHANICAL DESIGN

ELECTRICAL DESIGN

GOVERNMENT REPRESENTATIVE:

REVISIONS

REV. NO. DATE APPD. BY

DRAWING #: DPW-010

PROJECT #: 010

IJO:

DATE: APRIL, 2022

SHEET TITLE NAME

PROJECT NAME

FT. BUCHANAN, PUERTO RICO

GENERAL

REPAIRS

BUILDING 223

CIVIL / ARCH. / DESIGN DEVELOPMENT

SCALE: AS SHOWN

OF

F.ZAYAS.

F.ZAYAS.

X

A.GONZALEZ.

C.IRIZARRY.

RECOMMENDED APPROVAL:

APPROVED BY:

GFCI

GFCI

ELECTRICAL DEMOLITION

PLAN.

ED-1

ELECTRICAL REMOVAL WORK NOTES (THIS SHEET ONLY):

REMOVE AND DISPOSE RECEPTACLES ON EACH BATHROOM.

REMOVE AND STORE FIRE DETECTION FIXTURES ON EACH BATHROOM

REMOVE AND STORE STROBELIGHTS ON BATHROOMS

REMOVE AND DISPOSE RECEPTACLES ON OFFICE AREA.

REMOVE AND DISPOSE LIGHTING FIXTURES ON BATHROOMS.

REMOVE AND DISPOSE LIGHTING SWITCHES ON BATHROOMS.6

ELECTRICAL REMOVAL WORK GENERAL NOTES (THIS SHEET ONLY):

DO NOT REMOVE CIRCUITS , THEY SHALL BE REUSED.

ELECTRICAL LEGEND

GFCI GROUND FAULT CURRENT INTERRUPTING RECEPTACLE.

EXISTING FIRE ALARM CONTROL PANEL

DUPPLEX RECEPTACLE

AutoCAD SHX Text

ICE MACHINE

AutoCAD SHX Text

BATHROOM 2

AutoCAD SHX Text

BATHROOM 1

AutoCAD SHX Text

FACP

FACP

20220512 General Repairs Bldg 223- T-1
Sheets and Views
Model
20220408 General Repairs Bldg 223-SI-1
Sheets and Views
SI-1
20220408 General Repairs Bldg 223-D-1
20220408 General Repairs Bldg 223-D-2
20220523 General Repairs Bldg 223-A-1
20220408 General Repairs Bldg 223-A-2
20220506 General Repairs Bldg 223-ED-1
20220506 General Repairs Bldg 223-EI-1
20220606 General Repairs Bldg 223-A-1 review.pdf
Sheets and Views
A-1
20220606 General Repairs Bldg 223-A-2 review.pdf
Sheets and Views
A-2
20220606 General Repairs Bldg 223-D-1 review.pdf
Sheets and Views
D-1
20220606 General Repairs Bldg 223-D-2 review.pdf
Sheets and Views
D-2
20220606 General Repairs Bldg 223-ED-1 review.pdf
Sheets and Views
ED-1
20220606 General Repairs Bldg 223-D-1 review.pdf
Sheets and Views
D-1
20220606 General Repairs Bldg 223-D-2 review.pdf
Sheets and Views
D-2

File details come from the government source that posted it. Updated .