Attachment04-Vindicator-VCC-2-and-SAW-2-Data-Sheet (IDS).pdf
PDF 191 KB Posted
- Attached to
- FW Building 196 Alarm Federal contract opportunity
- Solicitation number
- FA489720QA029
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment03-Vindicator-Area-Commander-Data-Sheet (VAC).pdf | ||
| Attachment05-Vindicator-VSS-Data-Sheet (IDS).pdf | ||
| COMBO-20QA029-FW Bldg 196 Alarm.pdf | ||
| Attachment02-JA_BrandName-FW_Bldg196Alarm.pdf | ||
| Attachment06-DESIGN-FW_Bldg196Alarm.pptx | PPTX presentation | |
| Attachment01-Specifications.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VCC 2 / SAW 2
System Display, Command and Control
The Honeywell Vindicator® Command and Control display interface
(VCC 2) is our next generation CCDE (command and control display equipment). VCC 2 combines the rich feature set and intuitive interface of the original VCC with exciting new access control, video, event history, assisted response and situational awareness functionality.
VCC 2 integrates with either the V5 or V3 security network head-end devices to provide a common platform for security, fire and life safety, and building automation information delivered by the Vindicator security network.
FEATURES
The intuitive map-based display of facilities and alarm events provides enhanced situational and spatial awareness. Intuitive alarm responders, audible alarms, and an easy-to-navigate interface make it possible for a single end operator to manage thousands of alarm points. Security system events can be routed based on priority, origin or type and then sent to one or many
VCC 2 CCDE consoles.
• Access monitoring and control – VCC 2 enables the operator to lock/unlock portals or to even “lock down” an entire location in the event of an emergency. Discovering the location of personnel is one click away with the integrated “Who’s Here” functionality built into VCC 2.
• Alarm and event history – Operators will utilize this new feature to quickly identify recent events and their bearing on the current security status of a single facility or an entire base.
• Situational awareness indicators – VCC 2 now displays customizable icons that depict any number of current events, either on a base-wide level or down to a building-level display.
Operators can easily place graphical indicators on a map to geographically identify non-alarm events such as ambulances, security vehicles, construction crews, road closures, etc.
• Cordon creation – VCC 2 enables security forces personnel to create and size cordons electronically for heads up display on the site map. No more fumbling around with pencils and paper maps that only clutter the workspace.
• Assisted response wizard – Site guidelines for the targeted response to individual alarms can be easily programmed into
VCC 2 Operators can easily enter in the step-by-step instructions designed for the response to any type of alarm.
• One-click camera call up – When an alarm event is presented, the operator can now click on any cameras in the area to be presented with any number of views of an area. Because the information is graphically displayed, the operator can easily assess potential views from any camera in the area.
The SAW 2 interfaces with the Vindicator V5 and V3 head-end panels and the Vindicator Badge Manager to provide the capability to log, retrieve, and generate reports on all events and actions occurring during system operation.
ORDERING
VCC 2 / SAW 2 Workstations and Options
SE EDITIONAE EDITION
Honeywell Security Group
Honeywell Vindicator Technologies
3019 Alvin Devane Blvd, Bldg 4, Suite 430
Austin, TX 78735
1.512.301.8400 (sales)
1.800.367.1662 (support) www.honeywell.com
L/VCCD/D
May 2012 © 2012 Honeywell International Inc.
For more information: www.honeywellvindicator.com
SPECIFICATIONS
VCC 2 / SAW 2
System Display, Command and Control
Call Factory for pricing and options.
548-51100-01 AE VCC 2 Client Workstation (Win 7) 548-51100-11 AE VCC 2 Client Workstation (Win 10) 548-51150-01 AE VCC 2 SCIF Workstation (Win 7) 548-51150-11 AE VCC 2 SCIF Workstation (Win 10) 548-51200-01 AE VCC 2 / SAW 2 Client Workstation (Win 7) 548-51200-11 AE VCC 2 / SAW 2 Client Workstation (Win 10) 548-51300-01 AE VCC 2 / SAW 2 SCIF Workstation (Win 7) 548-51300-11 AE VCC 2 / SAW 2 SCIF Workstation (Win 10) 548-51400-01 AE SAW 2 Client Workstation (Win 7) 548-51400-11 AE SAW 2 Client Workstation (Win 10) 548-51500-01 AE SAW 2 SCIF Workstation (Win 7) 548-51500-11 AE SAW 2 SCIF Workstation (Win 10)
548-61100-01 SE VCC 2 Client Workstation (Win 7) 548-61100-11 SE VCC 2 Client Workstation (Win 10) 548-61150-01 SE VCC 2 SCIF Workstation (Win 7) 548-61150-11 SE VCC 2 SCIF Workstation (Win 10) 548-61200-01 SE VCC 2 / SAW 2 Client Workstation (Win 7) 548-61200-11 SE VCC 2 / SAW 2 Client Workstation (Win 10) 548-61300-01 SE VCC 2 / SAW 2 SCIF Workstation (Win 7) 548-61300-11 SE VCC 2 / SAW 2 SCIF Workstation (Win 10) 548-61400-01 SE SAW 2 Client Workstation (Win 7) 548-61400-11 SE SAW 2 Client Workstation (Win 10) 548-61500-01 SE SAW 2 SCIF Workstation (Win 7) 548-61500-11 SE SAW 2 SCIF Workstation (Win 10)
Intel Core I7 Processor 16GB DDR3 1600MHz RAM GeForce GT730 Graphics Card 2x 1TB Enterprise 7200 RPM Hard Drives RAID Level 1 SeaLevel 232/422/485 Serial Card
Microsoft Windows 7 or 10 Microsoft SQL 2012 R2 (SAW 2) Microsoft Office 2010 Professional USB Wired Keyboard USB Optical Mouse 24x SATA DVD
2U Rack Mount Chassis Lockable Faceplate 400w Power Supply 2x Removable HD Trays HDMI, DVI, VGA Cables USB Speakers
File details come from the government source that posted it. Updated .