013100 Project Management & Coordination
1.3 Letter designating Project Superintendent
1.3 Construction Schedule X
1.3 A comprehensive breakdown of the Schedule of Values
X
1.3 Accident Prevention Plan X
1.3 A list of Subcontractors for this project
1.3 Written statements from subcontractors certifying
compliance with applicable labor standard clauses
1.3
Satisfactory evidence of liability insurance coverage and workman’s compensation for the Contactor and all subcontractors
1.3 Waste Management Plan X
1.3 Quality Control Plan X
1.3 Temporary Storm Water Pollution Prevention Plan X
1.3 Indoor Air Quality Management Plan X
013200 Construction Schedule
1.3 Schedule of Values X
1.3 Construction Baseline Schedule X
1.3 CPM Reports X
1.3 Construction Schedule Updates X
1.3 Construction Schedule Revisions and Time Impact
Analysis X
013523 Safety Requirements
1.2 Accident Prevention Plan X
014000 Quality Requirements
1.4 Quality Control Plan X
1.4 Qualification Data X
1.4 Test Reports X
1.4 Accessibility Inspection Report X
1.4 Contractor's Quality Control Daily Reports X
1.4 Permits, Lcenses and Certificates X
015719.11 Indoor Air Quality Management
1.4 Indoor Air Quality Management Plan X
1.4 Product Data X
1.4 Inspection and Test Reports X
SUBMITTAL LIST
ACAD 241643 - Rehabilitate Boilers in Jordan Pond and Brown Mountain Gatehouses
SUBMITTAL REQUIREMENTS (indicate with an "X")
Spec. Sec.
Par.
No.
Description
INFORMATIONAL ACTION
R T
L
A B
T E
S T
R E
P O
R T
/C A
L C
O R
P L
A N
M fg
D
A T
A
I
N S
T R
U C
T
IO
N S
S H
O P
D R
A W
IN
G
S A
M P
L E
M fg
D
A T
A
I
N S
T R
U C
T
IO
N S
SUBMITTAL LIST
ACAD 241643 - Rehabilitate Boilers in Jordan Pond and Brown Mountain Gatehouses
SUBMITTAL REQUIREMENTS (indicate with an "X")
Spec. Sec.
Par.
No.
Description
INFORMATIONAL ACTION
016700 Product Requirements
1.3 Record Sumittals
1.3 Material Safety Data Sheets
1.3 Warranties, bonds and certifications X
1.3 Project Record Documents
017329 Cutting and Patching
1.2 Cutting and Patching Plan X
017340 Execution
1.2 Landfill Receipts
1.2 Quantity Surveys
017419 Construction Waste Management and Disposal
Attachments
1.4 Waste Management Plan X
1.4 Progress Documentation X
1.4 Landfill and Incinerator Disposal Records X
1.4 Qualification Data X
1.4 Progress Payment Requirements X
1.4 Closeout Submittals
017700 Closeout Procedures
1.3 Warranties, bonds and certifications X
1.3 Project Record Documents
017823 Operation and Maintenance Data
1.2 Copies of Manuals
017900 Demonstration and Training
1.3 Instruction Program
024000 Demolition, Cutting and Patching X
033000 Cast-In-Place Concrete
1.5 Laboratory Reports X X
1.6 Mix Proportions & Design X X
078400 Fire Stopping
1.4 Firestopping Materials X X
079200 Joint Sealants
2.1 Sealants X X
220000 Plumbing General Provisions
2.3 Hangers X X
R T
L
A B
T E
S T
R E
P O
R T
/C A
L C
O R
P L
A N
M fg
D
A T
A
I
N S
T R
U C
T
IO
N S
S H
O P
D R
A W
IN
G
S A
M P
L E
M fg
D
A T
A
I
N S
T R
U C
T
IO
N S
SUBMITTAL LIST
ACAD 241643 - Rehabilitate Boilers in Jordan Pond and Brown Mountain Gatehouses
SUBMITTAL REQUIREMENTS (indicate with an "X")
Spec. Sec.
Par.
No.
Description
INFORMATIONAL ACTION
2.4 Hanger Shields X X
2.5 Sleeves X X
220000 Plumbing Insulation
2.1 Pipe Insulation X X
221100 Water System
2.4 Valves X X
230000 Heating, Ventilation, and Air Conditioning
2.1 Piping X X
2.2A Fittings X X
2.2D Valves X X
2.2E Balancing Fittings X X
2.3 Boiler Burner Unit (Oil Fired) X X
2.5 Boiler System Control X X
2.6 Pipe Insulation X X
2.7 Ventilation Ductwork X X
2.9 Boiler Breeching X X
2.1 Duct Insulation X X
2.11 Fuel Oil Tank X X
2.12 Fuel Oil Piping X X
2.13 Radiator pressure testing results X X
2.13B Thermostatic Radiator Valves X X
3.1I Pipe Hangers X X
232213 Steam and Condensate Heating Piping
2.1B Steam Condensate Piping X X
2.2 Fittings for Steel Pipe X X
2.3 Fittings for Copper Tubing X X
2.6 Valves X X
2.7 Strainers X X
2.8A Safety Valves X X
2.8B Thermostatic Air Vent (Steam) X X
260500 Electrical General Provisions
260519 Power Conductors and Cables
2.1 Conductors X X
260526 Grounding and Bonding
2.2B Bare Copper Conductors X X
R T
L
A B
T E
S T
R E
P O
R T
/C A
L C
O R
P L
A N
M fg
D
A T
A
I
N S
T R
U C
T
IO
N S
S H
O P
D R
A W
IN
G
S A
M P
L E
M fg
D
A T
A
I
N S
T R
U C
T
IO
N S
SUBMITTAL LIST
ACAD 241643 - Rehabilitate Boilers in Jordan Pond and Brown Mountain Gatehouses
SUBMITTAL REQUIREMENTS (indicate with an "X")
Spec. Sec.
Par.
No.
Description
INFORMATIONAL ACTION
2.3 Connectors X X
2.4A Ground Rods X X
260529 Hangers and Supports for Electrical Systems
2.1 Support, Anchorage & Attachment Components X X
260533 Raceway and Boxes for Electrical Systems
2.1 Metal Conduit & Tubing
2.2 Nonmetallic Conduit & Tubing
2.3 Metal Wireways
2.4 Surface Raceways
2.5 Boxes, Enclosures, and Cabinets