AutoCAD SHX Text

MUSEUM

AutoCAD SHX Text

MUSEUM

AutoCAD SHX Text

FRENCHMAN

AutoCAD SHX Text

ISLE AU HAUT

AutoCAD SHX Text

16 MILES TO

AutoCAD SHX Text

BERNARD

AutoCAD SHX Text

OCEAN

AutoCAD SHX Text

SWAN ISLAND

AutoCAD SHX Text

FERRY TO

AutoCAD SHX Text

ATLANTIC

AutoCAD SHX Text

AutoCAD SHX Text

COVE

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

BEACH

AutoCAD SHX Text

SWIM

AutoCAD SHX Text

SEAWALL

AutoCAD SHX Text

HARBOR

AutoCAD SHX Text

BASS

AutoCAD SHX Text

GREAT

AutoCAD SHX Text

ISLAND

AutoCAD SHX Text

CRANBERRY

AutoCAD SHX Text

HARBOR

AutoCAD SHX Text

NORTHEAST

AutoCAD SHX Text

HARBOR

AutoCAD SHX Text

SOUTHWEST

AutoCAD SHX Text

ATLANTIC

AutoCAD SHX Text

OCEAN

AutoCAD SHX Text

MARSH

AutoCAD SHX Text

PRETTY

AutoCAD SHX Text

AIRPORT

AutoCAD SHX Text

ISLAND

AutoCAD SHX Text

THOMPSON

AutoCAD SHX Text

MT. DESERT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ISLAND

AutoCAD SHX Text

HQ.

AutoCAD SHX Text V.C.

AutoCAD SHX Text

AutoCAD SHX Text

HARBOR

AutoCAD SHX Text

BAR

AutoCAD SHX Text

& ELLSWORTH

AutoCAD SHX Text

TO

AutoCAD SHX Text

AutoCAD SHX Text

LITTLE

AutoCAD SHX Text

CRANBERRY

AutoCAD SHX Text

ISLAND

AutoCAD SHX Text

BAKER

AutoCAD SHX Text

ISLAND

AutoCAD SHX Text

SWIM BEACH

AutoCAD SHX Text

BLACKWOODS

AutoCAD SHX Text

FABBRI

AutoCAD SHX Text

ATLANTIC

AutoCAD SHX Text

OCEAN

AutoCAD SHX Text

ONE WAY

AutoCAD SHX Text

STATION

AutoCAD SHX Text

ENTRANCE

AutoCAD SHX Text

ONE WAY

AutoCAD SHX Text

AutoCAD SHX Text

BROOK

AutoCAD SHX Text

BEAR

AutoCAD SHX Text

HARBOR

AutoCAD SHX Text

BAR

AutoCAD SHX Text

BAY

AutoCAD SHX Text

AutoCAD SHX Text

PENINSULA

AutoCAD SHX Text

SCHOODIC

AutoCAD SHX Text

& GOULDSBORO

AutoCAD SHX Text

HARBOR

AutoCAD SHX Text

BIRCH

AutoCAD SHX Text

AutoCAD SHX Text

TO

AutoCAD SHX Text

AutoCAD SHX Text

& WEST GOULDSBORO

AutoCAD SHX Text

TO

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ISLE AU

AutoCAD SHX Text

ATLANTIC

AutoCAD SHX Text

HAUT

AutoCAD SHX Text

OCEAN

AutoCAD SHX Text

PARK

AutoCAD SHX Text

NATIONAL

AutoCAD SHX Text

ACADIA

AutoCAD SHX Text

BUCKSPORT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BANGOR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ELLSWORTH

AutoCAD SHX Text

GRAHAM

AutoCAD SHX Text

LAKE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

LAKE

AutoCAD SHX Text

GRAND

AutoCAD SHX Text

AutoCAD SHX Text

ISLE AU HAUT

AutoCAD SHX Text

SCALE OF MILES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE OF MILES

AutoCAD SHX Text

SCALE OF KILOMETERS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ACADIA NATIONAL PARK

AutoCAD SHX Text

PICNIC AREA

AutoCAD SHX Text

AIRPORT

AutoCAD SHX Text

LIGHTHOUSE

AutoCAD SHX Text

CAMPGROUND

AutoCAD SHX Text

PARKING

AutoCAD SHX Text

INFORMATION CENTER

AutoCAD SHX Text

RANGER STATION

AutoCAD SHX Text

PARK HEADQUARTERS

AutoCAD SHX Text

VISITOR CENTER

AutoCAD SHX Text V.C.

AutoCAD SHX Text

HQ.

AutoCAD SHX Text

RIVER

AutoCAD SHX Text

FERRY ROUTE

AutoCAD SHX Text

UNPAVED ROAD

AutoCAD SHX Text

COUNTY LINE

AutoCAD SHX Text

PAVED ROAD

AutoCAD SHX Text

PARK BOUNDARY

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

STATE

AutoCAD SHX Text

NATIONAL PARK SERVICE

AutoCAD SHX Text

DENVER SERVICE CENTER

AutoCAD SHX Text

REGION

AutoCAD SHX Text

COUNTY

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

TITLE OF DRAWING

AutoCAD SHX Text

REHABILITATE BOILERS AT GATEHOUSES

AutoCAD SHX Text

JORDAN POND AND BROWN MOUNTAIN GATE HOUSES

AutoCAD SHX Text 60,008

AutoCAD SHX Text

ACAD

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

HANCOCK

AutoCAD SHX Text

MAINE

AutoCAD SHX Text

CONSTRUCTION DRAWINGS

AutoCAD SHX Text

ACAD 241643

AutoCAD SHX Text

OF

AutoCAD SHX Text

PKG.

AutoCAD SHX Text

NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

AutoCAD SHX Text

ACADIA NATIONAL PARK

AutoCAD SHX Text

NORTHEAST

AutoCAD SHX Text

MAINE

AutoCAD SHX Text BOUNDARY MAP 123/80,011 5/86; USGS TOPO MAP 1971; PARK MINI FOLDER; COVER SHEET REVISED & REDRAWN 1/94. UPDATED 10/98. SGS.

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

PROJECT LOCATION

AutoCAD SHX Text

SHEET - 2 3 4 5 6 7

AutoCAD SHX Text TITLE OF SHEET COVER SHEET & PROJECT LOCATIONS PLAN LEGEND JP DEMOLITION PLAN JP PROPOSED PLAN BM DEMOLITION PLAN BM PROPOSED PLAN DETAILS AND SCHEDULES

AutoCAD SHX Text

INDEX OF SHEETS

AutoCAD SHX Text

SUB SHEET 1 2 3 4 5 6 7

4/21/21

04/21/2021

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

PMIS/PKG NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

REHABILITATE GATEHOUSE BOILERS

AutoCAD SHX Text

JORDAN POND & BROWN MOUNTAIN

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

AutoCAD SHX Text 60,008

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DC

AutoCAD SHX Text

KC

AutoCAD SHX Text

RB

AutoCAD SHX Text

ACADIA NATIONAL PARK

AutoCAD SHX Text

ACAD241643

AutoCAD SHX Text

AutoCAD SHX Text

%%UDUCTWORK STANDARDS AND SYMBOLS

AutoCAD SHX Text

%%UDESCRIPTION

AutoCAD SHX Text

HOT WATER SUPPLY

AutoCAD SHX Text %%uPIPING SERVICE LEGEND

AutoCAD SHX Text

A.C. REF. LIQUID

AutoCAD SHX Text

HOT WATER RETURN

AutoCAD SHX Text

CHILLED WATER SUPPLY

AutoCAD SHX Text

A.C. REF. SUCTION (VAPOR)

AutoCAD SHX Text

FUEL OIL BURNER SUPPLY

AutoCAD SHX Text

CHILLED WATER RETURN

AutoCAD SHX Text

FUEL OIL FILL

AutoCAD SHX Text

NATURAL GAS PIPING

AutoCAD SHX Text

FUEL OIL VENT

AutoCAD SHX Text

6" HWS

AutoCAD SHX Text

%%UNEW

AutoCAD SHX Text %%uGRILLE, REGISTERS, DIFFUSERS & AIRFLOW

AutoCAD SHX Text

%%UDESIGNATION

AutoCAD SHX Text %%uEQUIPMENT TAG LEGEND

AutoCAD SHX Text

45%%D ROUND

AutoCAD SHX Text

DUCT ELBOW

AutoCAD SHX Text

90%%D ROUND

AutoCAD SHX Text

DUCT ELBOW

AutoCAD SHX Text

MOTOR OPERATED DAMPER

AutoCAD SHX Text

%%USYMBOLS

AutoCAD SHX Text 12"%%C

AutoCAD SHX Text

%%UEXISTING TO REMAIN

AutoCAD SHX Text

SUPPLY GRILL

AutoCAD SHX Text

EXHAUST GRILLE

AutoCAD SHX Text

FLEXIBLE DUCT

AutoCAD SHX Text

NEW CONNECTION TO EXISTING

AutoCAD SHX Text

BASEBOARD RADIATION

AutoCAD SHX Text

FLOW SWITCH

AutoCAD SHX Text

DIRECTION OF FLOW

AutoCAD SHX Text

PIPE RISE/DROP

AutoCAD SHX Text

THERMOMETER

AutoCAD SHX Text

PIPE CAP

AutoCAD SHX Text

AUTOMATIC AIR VENT

AutoCAD SHX Text

DRIP LEG

AutoCAD SHX Text

PIPE GUIDE

AutoCAD SHX Text

CONTROL VALVE (3-WAY)

AutoCAD SHX Text

PRESSURE RELIEF VALVE

AutoCAD SHX Text

UNION

AutoCAD SHX Text

CONTROL VALVE (2-WAY)

AutoCAD SHX Text

SHUT-OFF VALVE

AutoCAD SHX Text

CHECK VALVE

AutoCAD SHX Text

%%UHEATING AND VENTING SYMBOLS

AutoCAD SHX Text

BALANCING VALVE

AutoCAD SHX Text

ROUND SUPPLY OR OUTSIDE AIR DUCT UP

AutoCAD SHX Text

ROUND RETURN OR EXHAUST AIR DUCT UP

AutoCAD SHX Text

DIRECTION OF AIRFLOW

AutoCAD SHX Text

DUCT PLAN-INCLINED DROP (DOWNSTREAM END LOWER)

AutoCAD SHX Text

DUCT PLAN-INCLINED RISE (DOWNSTREAM END HIGHER)

AutoCAD SHX Text

ACCESS DOOR

AutoCAD SHX Text

FLEXIBLE CONNECTION

AutoCAD SHX Text

BACKDRAFT DAMPER

AutoCAD SHX Text

VOLUME DAMPER (OPPOSED BLADE TYP.)

AutoCAD SHX Text

DUCT SECTION-SUPPLY OR OUTSIDE AIR FIRST FIGURE IS WIDTH SECOND FIGURE IS HEIGHT

AutoCAD SHX Text 30x12

AutoCAD SHX Text

TRIPLE DUTY VALVE

AutoCAD SHX Text

BACKFLOW PREVENTER

AutoCAD SHX Text

FLOW CONTROL VALVE

AutoCAD SHX Text

FUEL OIL FUSIBLE SHUT-OFF

AutoCAD SHX Text

PIPE ANCHOR

AutoCAD SHX Text

LOW WATER CUT-OFF

AutoCAD SHX Text

LWCO

AutoCAD SHX Text

CONTROL GROUP

AutoCAD SHX Text S

AutoCAD SHX Text

PRESSURE GAUGE

AutoCAD SHX Text

TCP

AutoCAD SHX Text

TEMPERATURE CONTROL PANEL

AutoCAD SHX Text

DRAIN-OFF VALVE

AutoCAD SHX Text

STRAINER W/DRAIN & HOSE CONN.

AutoCAD SHX Text

PRESSURE REDUCING VALVE (WATER)

AutoCAD SHX Text

DIFFERENTIAL PRESSURE REGULATING VALVE

AutoCAD SHX Text

INCREASER OR DECREASER CONCENTRIC

AutoCAD SHX Text

INCREASER OR DECREASER ECCENTRIC

AutoCAD SHX Text

UH-1 11.7 MBH

AutoCAD SHX Text

HVAC EQUIPMENT TAG IDENTIFICATION

AutoCAD SHX Text D.O.

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text

THERMOSTAT; H-HEATING, C-COOLING

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text D.O.

AutoCAD SHX Text D.O.

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text F&T

AutoCAD SHX Text

TEMPERATURE CONTROL PANEL

AutoCAD SHX Text

STEAM TRAP

AutoCAD SHX Text

DUCT SMOKE DETECTOR

AutoCAD SHX Text

EXISTING TO REMAIN

AutoCAD SHX Text

EXISTING TO BE REMOVED

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

NEW

AutoCAD SHX Text

ABBREV.

AutoCAD SHX Text

DESIGNATION

AutoCAD SHX Text

ABBREV.

AutoCAD SHX Text

DESIGNATION

AutoCAD SHX Text

ACL EA OA RA RLA SA CA VA

AutoCAD SHX Text ACOUSTIC DUCT LINER EXHAUST AIR OUTDOOR AIR RETURN AIR RELIEF AIR SUPPLY AIR COMBUSTION AIR VENTILATION AIR

AutoCAD SHX Text

DIFFUSER TAG WITH AIRFLOW (CUBIC FEET PER MINUTE)

AutoCAD SHX Text BOTTOM BRANCH TAKE-OFF (ALL AIR TERMINALS SHALL HAVE VOLUME DAMPER UNLESS OTHERWISE NOTED)

AutoCAD SHX Text

SG-1 XXX CFM

AutoCAD SHX Text

EG-1 XXX CFM

AutoCAD SHX Text

SD-1 XXX CFM

AutoCAD SHX Text

TYPICAL REGISTER/GRILLE

AutoCAD SHX Text

TYPICAL BOTTOM OF DUCT DIFFUSER DROP

AutoCAD SHX Text

TAG

AutoCAD SHX Text

DESIGNATION

AutoCAD SHX Text

EHWS

AutoCAD SHX Text

EFO

AutoCAD SHX Text

EFO

AutoCAD SHX Text

ECWR

AutoCAD SHX Text

ENG

AutoCAD SHX Text

EHWR

AutoCAD SHX Text

ECWS

AutoCAD SHX Text

EL

AutoCAD SHX Text

ES

AutoCAD SHX Text

EFOS

AutoCAD SHX Text

HWS

AutoCAD SHX Text

FO

AutoCAD SHX Text

FO

AutoCAD SHX Text

CWR

AutoCAD SHX Text

NG

AutoCAD SHX Text

HWR

AutoCAD SHX Text

CWS

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text

FOS

AutoCAD SHX Text

PIPE SIZE

AutoCAD SHX Text

SERVICE DESIGNATION

AutoCAD SHX Text

PIPING LINE DESIGNATIONS

AutoCAD SHX Text

MOD

AutoCAD SHX Text

FD

AutoCAD SHX Text

BDD

AutoCAD SHX Text

FIRE DAMPER (WITH ACCESS DOORS UPSTREAM & DOWN STREAM OF DAMPER)

AutoCAD SHX Text 12/10

AutoCAD SHX Text

OVAL DUCT SIZE- FIRST # IS SIDE SHOWN

AutoCAD SHX Text 12x10

AutoCAD SHX Text

RECTANGULAR DUCT SIZE- FIRST # IS SIDE SHOWN

AutoCAD SHX Text 18x12

AutoCAD SHX Text

ACOUSTICALLY LINED DUCTWORK - DIMENSIONS ARE CLEAR INSIDE

AutoCAD SHX Text

RECTANGULAR DUCT TRANSITION TO ROUND DUCT

AutoCAD SHX Text

DUCT SECTION-EXHAUST OR RETURN AIR

AutoCAD SHX Text

ROUND DUCT DIAMETER IN INCHES

AutoCAD SHX Text 12"%%C

AutoCAD SHX Text 30x12

AutoCAD SHX Text 12"%%C

AutoCAD SHX Text

RECTANGULAR RETURN OR EXHAUST DUCT UP

AutoCAD SHX Text

RECTANGULAR SUPPLY OR OUTSIDE AIR DUCT UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

AD

AutoCAD SHX Text

FC

AutoCAD SHX Text

ER RD RG RR SD LSD SR TD TG TR VD EG WR WG

AutoCAD SHX Text EXHAUST REGISTER RETURN DIFFUSER RETURN GRILLE RETURN REGISTER SUPPLY DIFFUSER LINEAR SUPPLY DIFFUSER SUPPLY REGISTER TRANSFER DIFFUSER TRANSFER GRILLE TRANSFER REGISTER VOLUME DAMPER EXHAUST GRILLE WALL REGISTER WALL GRILLE

AutoCAD SHX Text AHU-1 AS-1 B-1 CHP-1 CONV-1 CP-1 CT-1 CUH-1 EF-1 HRU-1 HRV-1 WH-1 FC-1 FTR-1 HE-1 HC-1 HP-1 L-1 P-1 UH-1 UV-1 UVHP-1 VAV-1 VH-1 WAHP-1 WWHP-1 XT-1 HV-1 HVAC-1

AutoCAD SHX Text AIR HANDLING UNIT DESIGNATION AIR SEPARATOR DESIGNATION BOILER DESIGNATION CONSOLE HEAT PUMP DESIGNATION CONVECTOR UNIT DESIGNATION A/C CONDENSATE PUMP DESIGNATION COOLING TOWER DESIGNATION CABINET UNIT HEATER DESIGNATION EXHAUST FAN DESIGNATION HEAT RECOVERY UNIT DESIGNATION HEAT RECOVERY VENTILATOR DESIGNATION WATER HEATER DESIGNATION FAN COIL DESIGNATION FINNED TUBE RADIATION DESIGNATION HEAT EXCHANGER DESIGNATION HEATING COIL DESIGNATION HEAT PUMP DESIGNATION LOUVER DESIGNATION PUMP DESIGNATION UNIT HEATER DESIGNATION UNIT VENTILATOR DESIGNATION UNIT VENTILATOR HEAT PUMP DESIGNATION VARIABLE AIR VOLUME BOX DESIGNATION VENT HOOD DESIGNATION WATER-AIR HEAT PUMP DESIGNATION WATER-WATER HEAT PUMP DESIGNATION EXPANSION TANK DESIGNATION HEATING AND VENTILATION UNIT DESIGNATION HEATING, VENTILATION AND AIR CONDITIONING UNIT DESIGNATION

AutoCAD SHX Text

A.C. CONDENSATE DRAIN

AutoCAD SHX Text

CD

AutoCAD SHX Text

ECD

AutoCAD SHX Text

SANITARY WASTE (CONDENSATE DRAIN) CLEANOUT

AutoCAD SHX Text

CO

AutoCAD SHX Text

CHILLED/HEATING WATER RETURN

AutoCAD SHX Text

CHILLED/HEATING WATER SUPPLY

AutoCAD SHX Text

C/HWS

AutoCAD SHX Text

C/HWR

AutoCAD SHX Text

HEAT PUMP SUPPLY

AutoCAD SHX Text

HPS

AutoCAD SHX Text

HPR

AutoCAD SHX Text

HEAT PUMP RETURN

AutoCAD SHX Text S

AutoCAD SHX Text D

AutoCAD SHX Text S

AutoCAD SHX Text D

AutoCAD SHX Text S

AutoCAD SHX Text D

AutoCAD SHX Text E 130

AutoCAD SHX Text

RA/EA GRILLE

AutoCAD SHX Text

SA DIFFUSER

AutoCAD SHX Text

TURNING VANES

AutoCAD SHX Text

GRILLE/DIFFUSER DESIGNATION, SEE SCHEDULE

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

AIRFLOW, CFM

AutoCAD SHX Text

CIRCULATING PUMP

AutoCAD SHX Text 2.5

AutoCAD SHX Text

FLOW RATE TO HEAT UNIT, GPM

AutoCAD SHX Text

FINTUBE RADIATION SYMBOL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VENTILATION THERMOSTAT, MAKES

AutoCAD SHX Text T

AutoCAD SHX Text V

AutoCAD SHX Text

CONTACT ON TEMPERATURE RISE

AutoCAD SHX Text

48" AFF

AutoCAD SHX Text S

AutoCAD SHX Text

TEMPERATURE SENSOR

AutoCAD SHX Text

%%UGENERAL NOTES

AutoCAD SHX Text

1. EXISTING CONDITIONS HAVE BEEN ESTABLISHED BASED ON INFORMATION PROVIDED BY ANP AND EXISTING CONDITIONS HAVE BEEN ESTABLISHED BASED ON INFORMATION PROVIDED BY ANP AND LIMITED SITE VISITS. CONTRACTOR TO VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS PRIOR TO BIDDING. 2. PIPING SHALL BE RUN AS DIRECT AS POSSIBLE, PARALLEL TO & FORMING RIGHT ANGLES TO PIPING SHALL BE RUN AS DIRECT AS POSSIBLE, PARALLEL TO & FORMING RIGHT ANGLES TO THE LINES OF THE BUILDING, SUPPORTED FROM THE STRUCTURE, FREE FROM POCKETS & SAGS & PITCHED TO LOW POINT DRAINS. 3. LOCATE ALL VALVES FOR EASY ACCESS & OPERATION. DO NOT LOCATE VALVES W/STEMS LOCATE ALL VALVES FOR EASY ACCESS & OPERATION. DO NOT LOCATE VALVES W/STEMS BELOW HORIZONTAL. 4. ALL EXTERIOR WALL PENETRATIONS SHALL BE SEALED WEATHERTIGHT. ALL EXTERIOR WALL PENETRATIONS SHALL BE SEALED WEATHERTIGHT. 5. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURERS' RECOMMENDATIONS. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURERS' RECOMMENDATIONS. 6. WORK SHALL BE DONE IN ACCORDANCE WITH LOCAL AND STATE CODES AND REGULATIONS. WORK SHALL BE DONE IN ACCORDANCE WITH LOCAL AND STATE CODES AND REGULATIONS. 7. MECHANICAL CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER TRADES. MECHANICAL CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER TRADES. 8. ALL CUTTING AND PATCHING SHALL BE PROVIDED BY GENERAL CONTRACTOR. ALL CUTTING AND PATCHING SHALL BE PROVIDED BY GENERAL CONTRACTOR. 9. ALL PIPING SHALL BE INSULATED. ALL PIPING SHALL BE INSULATED. 10. ALL PIPING SHALL BE RUN CONCEALED AND ON WARM SIDE OF BUILDING INSULATION WHEREVER ALL PIPING SHALL BE RUN CONCEALED AND ON WARM SIDE OF BUILDING INSULATION WHEREVER POSSIBLE UNLESS NOTED OTHERWISE. 11. PIPING IS SHOWN DIAGRAMMATICALLY. EXACT LOCATION TO BE ADJUSTED AS REQUIRED TO SUIT PIPING IS SHOWN DIAGRAMMATICALLY. EXACT LOCATION TO BE ADJUSTED AS REQUIRED TO SUIT FIELD CONDITIONS. 12. ALL DIMENSIONS ARE APPROXIMATE AND ARE TO BE VERIFIED IN THE FIELD. ALL DIMENSIONS ARE APPROXIMATE AND ARE TO BE VERIFIED IN THE FIELD. 13. ALL REDUCTIONS IN NEW HOT WATER/CHILLED WATER/STEAM PIPE SIZES IN THE DIRECTION OF ALL REDUCTIONS IN NEW HOT WATER/CHILLED WATER/STEAM PIPE SIZES IN THE DIRECTION OF FLOW SHALL BE ACCOMPLISHED WITH INVERTED ECCENTRIC REDUCERS. 14. PROVIDE DRAINS AT ALL LOW POINTS IN THE WATER PIPING SYSTEM. PROVIDE DRAINS AT ALL LOW POINTS IN THE WATER PIPING SYSTEM. 15. COPPER PIPING SHALL BE TYPE 'L' OR 'K'. TYPE 'M' SHALL NOT BE USED FOR THIS PROJECT. COPPER PIPING SHALL BE TYPE 'L' OR 'K'. TYPE 'M' SHALL NOT BE USED FOR THIS PROJECT. 16. ALL HEAT PIPING RUNS SHALL BE INSULATED WITH 1" THICK, UNLESS INDICATED OTHERWISE, ALL HEAT PIPING RUNS SHALL BE INSULATED WITH 1" THICK, UNLESS INDICATED OTHERWISE, GLASS FIBER PIPE INSULATION WITH REINFORCED KRAFT - ALUMINUM FOIL JACKET. VALVES, UNIONS AND FLANGES SHALL NOT BE INSULATED. 17. ALL PIPING THROUGH ROOFS, WALLS AND PARTITIONS SHALL HAVE PIPE SLEEVES. ALL PIPING ALL PIPING THROUGH ROOFS, WALLS AND PARTITIONS SHALL HAVE PIPE SLEEVES. ALL PIPING PENETRATING FIRE RATED WALLS, FIRE RATED PARTITIONS OR FLOORS SHALL BE PROTECTED WITH A LISTED FIRE STOPPING SYSTEM PER NFPA 101, "CODE FOR SAFETY TO LIFE FROM FIRE IN BUILDING AND STRUCTURES", LATEST EDITION. 18. CONTRACTOR SHALL ASSUME MINOR PIPE AND FITTING REPLACEMENTS SHALL BE REQUIRED AT RUNOUTS/RISER TO RADIATORS ON IN THE LPS/LPC MAINS. FOR CONTRACT PURPOSES ASSUME (2) 5' SECTIONS AND (4) FITTINGS FOR EACH PIPE SIZE IN THE SYSTEM. INCLUDE FOR PIPE SIZES RANGING FROM 1" TO 2-1/2".

AutoCAD SHX Text

RADIANT HOT WATER SUPPLY

AutoCAD SHX Text

RADIANT HOT WATER RETURN

AutoCAD SHX Text

RHWS

AutoCAD SHX Text

RHWR

AutoCAD SHX Text

RADIANT ZONE PERIMETER

AutoCAD SHX Text %%uMISCELLANEOUS ABBREVIATIONS

AutoCAD SHX Text ANCHOR ACCESS DOOR ABOVE FINISHED FLOOR AIR PRESSURE DROP AVERAGE WATER TEMPERATURE BAROMETRIC DAMPER BACKDRAFT DAMPER BUILDING MANAGEMENT SYSTEM BOTTOM OF STEEL BRITISH THERMAL UNITS BRICK VENT COOLING CONDENSATE DRAINAGE CUBIC FEET PER MINUTE DRAIN DRY BULB ENTERING AIR TEMP. ECCENTRIC ELEVATION ENTERING WATER TEMPERATURE FRESH AIR FLEXIBLE CONNECTION FIRE DAMPER FULL LOAD AMPS GALLONS PER MINUTE HORSEPOWER HEATING, VENTILATING & AIR CONDITIONING HOT WATER BASEBOARD HERTZ LEAVING AIR TEMP. LINEAL FEET LOW PRESSURE CONDENSATE LOW PRESSURE STEAM LOCKED ROTOR AMPS LOW WATER CUT-OFF LEAVING WATER TEMPERATURE MAXIMUM THOUSAND BRITISH THERMAL UNITS PER HOUR MANUAL DAMPER MINIMUM MOTOR OPERATED DAMPER MANUAL VENT NORMALLY CLOSED OUTSIDE AIR OIL SAFETY VALVE PRESSURE DROP RUN IN COVER REVOLUTIONS PER MINUTE STATIC PRESSURE TOP OF STEEL TURNING VANES TYPICAL UNLESS NOTED OTHERWISE VENT VOLUME DAMPER WITH WET BULB ZONE DAMPER RADIANT ZONE RADIANT ZONE MANIFOLD

AutoCAD SHX Text A AD AFF APD AWT BD BDD BMS BOS BTU BV CD CFM D DB EAT ECC EL EWT FA FC FD FLA GPM HP HVAC HWBB HZ LAT LF LPC LPS LRA LWCO LWT MAX MBH MD MIN MOD MV N.C. OA OSV PD RIC RPM SP TOS TV TYP. U.N.O. V VD W/ WB ZD RZ RZM

AutoCAD SHX Text

ABBREV.

AutoCAD SHX Text

DESIGNATION

AutoCAD SHX Text

REFRIGERANT PIPING

AutoCAD SHX Text

ER

AutoCAD SHX Text R

AutoCAD SHX Text

STEAM SUPPLY

AutoCAD SHX Text

STEAM RETURN

AutoCAD SHX Text

CR

AutoCAD SHX Text

SS

AutoCAD SHX Text EXISTING TO REMAIN EXISTING RELOCATED NEW TO REPLACE EXISTING IN EXISTING LOCATION EXISTING TO BE REMOVED REMOVE & RELOCATE EXISTING CONNECT TO EXISTING

AutoCAD SHX Text

E ER NR R RR

AutoCAD SHX Text

%%UCOMMON ABBREVIATIONS

AutoCAD SHX Text

ABBREV.

AutoCAD SHX Text

DESIGNATION

AutoCAD SHX Text

ARROWS INDICATE DIRECTION OF BLOW

AutoCAD SHX Text

TYPICAL FLEX DUCT CONNECTION TO DIFFUSER

AutoCAD SHX Text

DIFFUSER TAG WITH AIRFLOW (CUBIC FEET PER MINUTE)

AutoCAD SHX Text

SD-1 XXX CFM

AutoCAD SHX Text

TYPICAL CEILING DIFFUSER

AutoCAD SHX Text

CIRCUIT SETTER/FLOW CONTROL VALVE

AutoCAD SHX Text

LOW PRESSURE STEAM

AutoCAD SHX Text

LPS

AutoCAD SHX Text

LPC

AutoCAD SHX Text

LOW PRESSURE CONDENSATE

AutoCAD SHX Text

LPS

AutoCAD SHX Text

LPC

BOILER

AutoCAD SHX Text

OIL STORAGE TANK

AutoCAD SHX Text

WATER HEATER

AutoCAD SHX Text

FFE APROX 6" HIGHER

AutoCAD SHX Text

6" STEP UP

AutoCAD SHX Text

LPC

AutoCAD SHX Text

LPS

AutoCAD SHX Text

LPS/LPC

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text 1 1/4"

AutoCAD SHX Text 2 1/2"

AutoCAD SHX Text

LPC

AutoCAD SHX Text

LPC

AutoCAD SHX Text 2 1/2"

AutoCAD SHX Text

LPS/LPC

AutoCAD SHX Text

LPC

AutoCAD SHX Text 1 1/4"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text

LPC

AutoCAD SHX Text

LPS/LPC

AutoCAD SHX Text 2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text V

AutoCAD SHX Text V

AutoCAD SHX Text

LPC

AutoCAD SHX Text 1 1/4"

AutoCAD SHX Text

LPS/LPC

AutoCAD SHX Text 2 1/2"

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text V

AutoCAD SHX Text V

AutoCAD SHX Text JORDAN POND GATE HOUSE BASEMENT FLOOR HEATING DEMOLITION PLAN SCALE: 3/16"=1'-0" ±

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

PMIS/PKG NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

REHABILITATE GATEHOUSE BOILERS

AutoCAD SHX Text

JORDAN POND & BROWN MOUNTAIN

AutoCAD SHX Text

JP DEMOLITION PLAN

AutoCAD SHX Text

AutoCAD SHX Text 60,008

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DC

AutoCAD SHX Text

KC

AutoCAD SHX Text

RB

AutoCAD SHX Text

ACADIA NATIONAL PARK

AutoCAD SHX Text

ACAD241643

AutoCAD SHX Text

AutoCAD SHX Text

JORDAN POND GATE HOUSE 1ST FLOOR HEATING DEMOLITION PLAN SCALE: 3/16"=1'-0" ±

AutoCAD SHX Text

1" UP/DN

AutoCAD SHX Text 1"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1"

AutoCAD SHX Text 1"

AutoCAD SHX Text

2" UP/DN

AutoCAD SHX Text

45 SF EDR

AutoCAD SHX Text

56 SF EDR

AutoCAD SHX Text

43-1/4 SF EDR

AutoCAD SHX Text

20 SF EDR

AutoCAD SHX Text

12-1/3 SF EDR

AutoCAD SHX Text

18 SF EDR

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text

45 SF EDR

AutoCAD SHX Text

EXISTING STEAM RADIATOR (TYP)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

JORDAN POND GATE HOUSE 2ND FLOOR HEATING DEMOLITION PLAN SCALE: 3/16"=1'-0" ±

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text 1"

AutoCAD SHX Text

22-1/2 SF EDR

AutoCAD SHX Text

63-3/4 SF EDR

AutoCAD SHX Text

55 SF EDR

AutoCAD SHX Text

80-3/4 SF EDR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ABBREVIATION:

AutoCAD SHX Text SF = SQUARE FEET EDR = EQUIVALENT DIRECT RADIATION. (1 SF EDR = 240 BTU/HR) DN = DOWN FFE = FINISHED FLOOR ELEVATION CW = COLD WATER EXST = EXISTING JB = JUNCTION BOX

AutoCAD SHX Text

AutoCAD SHX Text

KEY NOTES:

AutoCAD SHX Text REMOVE RADIATOR, RADIATOR VALVE, CONTROL VALVE, AND AIRVENT. SAVE RADIATOR FOR REINSTALLATION AFTER REFURBISHMENT. REMOVE EXISTING WEIL-MCLAIN 396 MBH GROSS OUTPUT BOILER, CLOSE BOILER STEAM PIPING, BOILER WATER FEED SYSTEM, FUEL LINE, AND ELECTRICAL WIRING BACK TO LOCAL JB IN PREPARATION FOR NEW BOILER INSTALLATION. CUT PIPING LEVEL AT FLOOR IN PREPARATION TO REROUTE CONDENSATE RETURNS. REMOVE CONDENSATE RETURN PIPING BACK TO BOILER. CUT PIPING FLUSH AT CURB IN PREPARATION FOR REROUTING / REPLACING CONDENSATE RETURN. REMOVE END OF MAIN VENTS AND PREPARE 3/4" VENT RISER FOR EXTENSION. REMOVE EXISTING THERMOSTAT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1"

AutoCAD SHX Text 1"

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text

STEEL SUPPORT POST

AutoCAD SHX Text

CONCRETE CEILING BEAM

AutoCAD SHX Text

CONCRETE CURB (6"X6")

AutoCAD SHX Text

HATCH LEGEND

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXIST

AutoCAD SHX Text

EXST

AutoCAD SHX Text

EXST

AutoCAD SHX Text

BOILER TO BE REMOVED

AutoCAD SHX Text GENERAL MECHANICAL AND ELECTRICAL REMOVALS NOTES: : 1. AN ATTEMPT HAS BEEN MADE TO INDICATE ITEMS FOR REMOVAL. SOME ITEMS REQUIRING REMOVAL MAY INADVERTENTLY NOT BE AN ATTEMPT HAS BEEN MADE TO INDICATE ITEMS FOR REMOVAL. SOME ITEMS REQUIRING REMOVAL MAY INADVERTENTLY NOT BE SHOWN. REMOVE ALL ITEMS AS REQUIRED FOR NEW CONSTRUCTION UNLESS NOTED OTHERWISE. VERIFY EXISTING CONDITIONS IN THE FIELD. 2. ALL REMOVED ITEMS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE PREMISES, UNLESS ALL REMOVED ITEMS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE PREMISES, UNLESS INDICATED OTHERWISE. 3. REMOVE EXISTING HEATING SYSTEM COMPONENTS AS INDICATED AND REQUIRED TO COMPLETE NEW WORK. REMOVE EXISTING HEATING SYSTEM COMPONENTS AS INDICATED AND REQUIRED TO COMPLETE NEW WORK. 4. REMOVE EXISTING EQUIPMENT ELECTRICAL CONNECTIONS AND WIRING, ETC. AS INDICATED AND REQUIRED TO COMPLETE NEW WORK. REMOVE EXISTING EQUIPMENT ELECTRICAL CONNECTIONS AND WIRING, ETC. AS INDICATED AND REQUIRED TO COMPLETE NEW WORK. REMOVE ALL UNUSED/ABANDONED ELECTRICAL AND POWER SYSTEMS COMPONENTS.

AutoCAD SHX Text GENERAL NOTES: 1. THE CONTRACTOR SHALL CONFIRM ACTUAL CONDITIONS IN THE FIELD PRIOR TO SUBMITTING A BID. THE CONTRACTOR SHALL CONFIRM ACTUAL CONDITIONS IN THE FIELD PRIOR TO SUBMITTING A BID. 2. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH LOCAL AND STATE CODES AND REGULATIONS. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH LOCAL AND STATE CODES AND REGULATIONS. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURING THAT ALL BOILER RELATED ELECTRICAL WORK MEETS CURRENT CODE CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURING THAT ALL BOILER RELATED ELECTRICAL WORK MEETS CURRENT CODE REQUIREMENTS AS PART OF THIS WORK. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONNECTIONS TO NEW AND EXISTING CONTROLS AS REQUIRED FOR A COMPLETE THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONNECTIONS TO NEW AND EXISTING CONTROLS AS REQUIRED FOR A COMPLETE INSTALLATION. 5. CONTRACTOR SHALL INSTALL ALL FUEL PIPING AND REQUIRED ACCESSORIES AS INDICATED OR REQUIRED FOR COMPLETE CODE CONTRACTOR SHALL INSTALL ALL FUEL PIPING AND REQUIRED ACCESSORIES AS INDICATED OR REQUIRED FOR COMPLETE CODE COMPLIANT SYSTEM. 6. ADJUST PIPING AS NEEDED TO CONNECT TO NEW BOILER AND MAINTAIN PROPER FLOW IN EXISTING PIPE RUNS, MATCH VALVES, ADJUST PIPING AS NEEDED TO CONNECT TO NEW BOILER AND MAINTAIN PROPER FLOW IN EXISTING PIPE RUNS, MATCH VALVES, STRAINERS, CIRCUIT SETTERS, ETC. TO DESIRED FLOW AND PIPE DIAMETER. 7. THE SCOPE OF THE PROJECT SHALL INCLUDE THE INSTALLATION OF NEW PIPING, VALVES, TANKS, SENSORS, CONTROLS, BOILER, VENT THE SCOPE OF THE PROJECT SHALL INCLUDE THE INSTALLATION OF NEW PIPING, VALVES, TANKS, SENSORS, CONTROLS, BOILER, VENT PIPING, PIPING INSULATION, ETC. 8. CONTRACTOR TO REPLACE ANY AND ALL CONTROLS THAT PERTAIN TO BOILER CONTRACTOR TO REPLACE ANY AND ALL CONTROLS THAT PERTAIN TO BOILER 9. EXISTING CONDITION SHOWN ON PLAN OBTAINED FROM HISTORICAL PLANS PROVIDED BY GOVERNMENT.EXISTING CONDITION SHOWN ON PLAN OBTAINED FROM HISTORICAL PLANS PROVIDED BY GOVERNMENT.

AutoCAD SHX Text DEMOLITION NOTES: 1. REMOVE EXISTING BOILER AND ACCESSORIES AS REQUIRED FOR INSTALLATION OF NEW BOILER. REMOVE EXISTING BOILER AND ACCESSORIES AS REQUIRED FOR INSTALLATION OF NEW BOILER. 2. CONTRACTOR IS RESPONSIBLE TO VISIT SITE AND VERIFY EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE TO VISIT SITE AND VERIFY EXISTING CONDITIONS. 3. REMOVE EXISTING BURNER. REMOVE ANY UNUSED WIRING BACK TO ELECTRICAL PANEL. REUSE EXISTING CONDUIT AND WIRING SO FAR REMOVE EXISTING BURNER. REMOVE ANY UNUSED WIRING BACK TO ELECTRICAL PANEL. REUSE EXISTING CONDUIT AND WIRING SO FAR AS PRACTICAL AND MODIFY AS REQUIRED FOR INSTALLATION OF NEW BOILER. 4. CONTRACTOR SHALL CUT PIPING AT LOCATIONS SHOWN ON PLANS.CONTRACTOR SHALL CUT PIPING AT LOCATIONS SHOWN ON PLANS.

AutoCAD SHX Text 1'-0'

AutoCAD SHX Text

AutoCAD SHX Text 6'

AutoCAD SHX Text 6'

AutoCAD SHX Text 3'

AutoCAD SHX Text

SCALE: 3/16"=

AutoCAD SHX Text

LEGEND:

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text

PIPING UP PIPING DOWN CONNECT TO EXISTING THERMOSTAT

AutoCAD SHX Text T

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1"

AutoCAD SHX Text

31.5 SF EDR

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text

35 SF EDR

AutoCAD SHX Text

35 SF EDR

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

39 SF EDR BELOW WINDOW SEAT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

WET RETURN (LPC) IN CONCRETE. ABANDON IN PLACE

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text

EXIST CW TO BOILER.

AutoCAD SHX Text 04/21/2021

AutoCAD SHX Text

BOILER

AutoCAD SHX Text

OIL STORAGE TANK

AutoCAD SHX Text

WATER HEATER

AutoCAD SHX Text

FFE APROX 6" HIGHER

AutoCAD SHX Text

6" STEP UP

AutoCAD SHX Text

LPC

AutoCAD SHX Text

LPS

AutoCAD SHX Text

LPS/LPC

AutoCAD SHX Text V

AutoCAD SHX Text 1"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text 1 1/4"

AutoCAD SHX Text

LPC

AutoCAD SHX Text

LPS/LPC

AutoCAD SHX Text

LPC

AutoCAD SHX Text 2 1/2"

AutoCAD SHX Text

LPS/LPC

AutoCAD SHX Text

LPC

AutoCAD SHX Text 1 1/4"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text

LPC

AutoCAD SHX Text

LPS/LPC

AutoCAD SHX Text 2"

AutoCAD SHX Text 1 1/2"

AutoCAD SHX Text V

AutoCAD SHX Text V

AutoCAD SHX Text V

AutoCAD SHX Text

LPC

AutoCAD SHX Text 1 1/4"

AutoCAD SHX Text

LPS/LPC

AutoCAD SHX Text 2 1/2"

AutoCAD SHX Text B-2

AutoCAD SHX Text 2"

AutoCAD SHX Text 1/2"

AutoCAD SHX Text

FOS

AutoCAD SHX Text 3/8"

AutoCAD SHX Text

LPC

AutoCAD SHX Text

LPC

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text L-1

AutoCAD SHX Text T

AutoCAD SHX Text V

AutoCAD SHX Text

JORDAN POND GATE HOUSE BASEMENT FLOOR HEATING PROPOSED PLAN SCALE: 3/16"=1'-0" ±

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

PMIS/PKG NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

REHABILITATE GATEHOUSE BOILERS

AutoCAD SHX Text

JORDAN POND & BROWN MOUNTAIN

AutoCAD SHX Text

JP PROPOSED PLAN

AutoCAD SHX Text

AutoCAD SHX Text 60,008

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DC

AutoCAD SHX Text

KC

AutoCAD SHX Text

RB

AutoCAD SHX Text

ACADIA NATIONAL PARK

AutoCAD SHX Text

ACAD241643

AutoCAD SHX Text

AutoCAD SHX Text

JORDAN POND GATE HOUSE 1ST FLOOR HEATING PROPOSED PLAN SCALE: 3/16"=1'-0" ±

AutoCAD SHX Text

JORDAN POND GATE HOUSE 2ND FLOOR HEATING PROPOSED PLAN SCALE: 3/16"=1'-0" ±

AutoCAD SHX Text

AutoCAD SHX Text

KEY NOTES:

AutoCAD SHX Text AFTER PRESSURE TESTING AND REFINISHING, REPLACE RADIATOR IN ORIGINAL LOCATION. SHIM RADIATOR TO PITCH TO STEAM SUPPLY/CONDENSATE CONNECTION. PROVIDE THERMOSTATIC RADIATOR VALVE WITH BUILT-IN VACUUM BREAKER, AND RADIATOR SERVICE VALVE IN ROOM WITH MAIN THERMOSTAT, USE VENTS ONLY; NO TRV. PROVIDE NEW BOILER AS SCHEDULED. PROVIDE CLOSE BOILER PIPING (RISER, HEADER, EQUALIZER, HARTFORD LOOP) PER BOILER MANUFACTURER'S REQUIREMENTS; EXCEPT PROVIDE DROP HEADER, ONE PIPE SIZE LARGER THAN MANUFACTURER'S REQUIREMENTS. PROVIDE PRIMARY AND SECONDARY PROBE-TYPE LWCO; PRIMARY PRESSURE CONTROL (SET 0.5 PSI WITH 1 PSI DIFFERENTIAL) AND SECONDARY PRESSURE CONTROL (SET TO BREAK AT 10 PSI), WITH PIGTAIL, SKIM TAPPING, PRESSURE GAUGE, DRAIN VALVE, SERVICE SWITCH, AND BAROMETRIC DRAFT. PROVIDE BOILER WATER FEEDER EQUIVALENT TO HYDROLEVEL MODEL VXT-120. PROVIDE TIGERLOOP FILTER/DEARATOR AT BURNER. SEE BOILER PIPING DETAIL ON SHEET 7, AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. CONNECT EXISTING LPC DROPS TO NEW FLOOR LEVEL WET RETURN. PROVIDE NEW FLOOR LEVEL CONDENSATE PIPING TO BOILER. PROVIDE NEW BACKFLOW PREVENTER EQUIVALENT TO 1/2" WATTS MODEL 9D, AND NEW BALL VALVE. CONNECT TO NEW WATER FEEDER. EXTEND VENT RISER TO THE EXTENT POSSIBLE (6" MINIMUM, 10" PREFFERED) AND PROVIDE MAIN VENT(S) SIZED TO VENT MAIN PIPING AIR VOLUME IN 3 MINUTES AT 2 OZ PRESSURE. PROVIDE NEW 8" DIAMETER FLUE PIPE FROM BOILER TO CHIMNEY. PROVIDE 7DAY, 24 HOUR, PROGRAMMABLE THERMOSTAT. PROVIDE COPPER FUEL LINE, AT 6'-8" MIN. A.F.F., FROM EXISTING FUEL TANK TO NEW BOILER. PROVIDE 14"H x 26"W (APPROXIMATE, FIELD VERIFY) LOUVER, EQUIVALENT TO RUSKIN MODEL ELF211. COLOR TO BE CHOSEN BY CONTRACTING OFFICER FROM STANDARD KYNAR COLORS. SIZE LOUVER TO OVERLAP EXISTING WINDOW FRAME. SEAL LOUVER FLANGE TO OUTSIDE OF EXISTING FRAME WITH BUTYL GLAZING TAPE, AND CLAMP THROUGH TO ALUMINUM TABS WITH SS SCREWS THROUGH THE LOUVER FLANGE FROM OUTSIDE, ON 8" CENTERS. DO NO PENETRATE EXISTING WINDOW FRAME WITH FASTENERS. PROVIDE 12" x 24" DUCT (WITH CENTER DIVIDER) CONNECTED TO LOUVER. SEAL WATER TIGHT AND PITCH BOTTOM BACK TO LOUVER. PROVIDE 12" W x 12" H MOTOR OPERATED DAMPER (MOD-1) IN OPEN ENDED DUCT. PROVIDE MAKE-ON-RISE THERMOSTAT AT CEILING AND CONNECT TO MOD-1. PROVIDE 12" W x 12" H DUCT, TURNED DOWN TO 12" X 6" DUCT TO WITHIN 6" OF FLOOR. PROVIDE 12" x 6" MOD-2 IN DROP DUCT. INTERLOCK MOD-2 WITH BOILER OPERATION. PROVIDE ALUMINUM BLANK OFF PLATE ADJACENT TO LOUVER TO ACCOMMODATE EXISTING DRYER VENT. MATCH LOUVER FLANGE OUTER DIMENSIONS, AND CONNECT/SEAL TO LOUVER WITH BUTYL TAPE AND ALUMINUM BACKER. PAINT TO MATCH LOUVER. PROVIDE 12" STAINLESS STEEL LINER. EXISTING CLAY FLUE MAY BE IN POOR CONDITION. PROVIDE AND INSTALL 12" STAINLESS STEEL FLUE LINER.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

STEEL SUPPORT POST

AutoCAD SHX Text

CONCRETE CEILING BEAM

AutoCAD SHX Text

CONCRETE CURB (6"X6")

AutoCAD SHX Text

HATCH LEGEND

AutoCAD SHX Text

ABBREVIATION:

AutoCAD SHX Text SF=SQUARE FEET EDR=EQUIVALENT DIRECT RADIATION. (1 SF EDR = 240 BTU/HR) DN=DOWN FFE=FINISHED FLOOR ELEVATION CW=COLD WATER EXST=EXISTING

AutoCAD SHX Text

LEGEND:

AutoCAD SHX Text T

AutoCAD SHX Text

PIPING UP PIPING DOWN CONNECT TO EXISTING THERMOSTAT

AutoCAD SHX Text GENERAL NOTES: 1. STEAM SUPPLY PIPING TO BE REPLACED FROM BOILER TO MAIN STEAM SUPPLY MAINS. STEAM SUPPLY PIPING TO BE REPLACED FROM BOILER TO MAIN STEAM SUPPLY MAINS. 2. ALL CONDENSATE RETURN PIPING BELOW WATER LINE (WET RETURNS), TO BE REPLACED. ALL CONDENSATE RETURN PIPING BELOW WATER LINE (WET RETURNS), TO BE REPLACED. 3. PIPING FROM OIL, WATER, ETC TO BE REPLACED TO NEAREST CONNECTION, ENSURE PIPING CONNECTION POINT HAS NO PIPING FROM OIL, WATER, ETC TO BE REPLACED TO NEAREST CONNECTION, ENSURE PIPING CONNECTION POINT HAS NO CORROSION 4. CONTRACTOR SHALL INSTALL PIPING INSULATION ON ALL ASSOCIATED STEAM PIPING AND COLD WATER PIPING. CONTRACTOR SHALL INSTALL PIPING INSULATION ON ALL ASSOCIATED STEAM PIPING AND COLD WATER PIPING. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURING THAT ALL BOILER RELATED WORK MEETS CURRENT CODE CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURING THAT ALL BOILER RELATED WORK MEETS CURRENT CODE REQUIREMENTS AS PART OF THIS WORK. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURING THAT ALL BOILER CONDITIONS, PIPING, VALVES, ETC ARE SAFE CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURING THAT ALL BOILER CONDITIONS, PIPING, VALVES, ETC ARE SAFE AND IN WORKING ORDER. IF BOILER CONDITIONS, PIPING, VALVES, ETC ARE NOT SAFE, OR HAVE CORROSION, OR ARE DAMAGED, CONTRACTOR MUST CONTACT ENGINEER FOR RESOLUTION. 7. CONTRACTOR TO REPLACE ANY AND ALL CONTROLS THAT PERTAIN TO THE BOILER. VERIFY EXACT CONTROL SEQUENCE CONTRACTOR TO REPLACE ANY AND ALL CONTROLS THAT PERTAIN TO THE BOILER. VERIFY EXACT CONTROL SEQUENCE OF EXISTING BOILERS. CONFIRM WITH GOVERNMENT AND CONTRACTING OFFICER AS NEEDED 8. EXISTING CONDITION SHOWN ON PLAN OBTAINED FROM HISTORICAL PLANS PROVIDED BY GOVERNMENT. EXISTING CONDITION SHOWN ON PLAN OBTAINED FROM HISTORICAL PLANS PROVIDED BY GOVERNMENT. 9. PITCH ALL NEW STEAM MAIN PIPING AT 1" IN 20 FEET MINIMUM. CHECK EXISTING MAINS FOR PITCH AND ADJUST TO PITCH ALL NEW STEAM MAIN PIPING AT 1" IN 20 FEET MINIMUM. CHECK EXISTING MAINS FOR PITCH AND ADJUST TO ELIMINATE ANY LOW POINTS. 10. PROVIDE CONCRETE HOUSEKEEPING PAD AT BOILER. PROVIDE CONCRETE HOUSEKEEPING PAD AT BOILER. 11. BOILERS SHALL HAVE SPRINKLER HEADS INSTALLED ABOVE.BOILERS SHALL HAVE SPRINKLER HEADS INSTALLED ABOVE.

AutoCAD SHX Text 1'-0'

AutoCAD SHX Text

AutoCAD SHX Text 6'

AutoCAD SHX Text 6'

AutoCAD SHX Text 3'

AutoCAD SHX Text

SCALE: 3/16"=

AutoCAD SHX Text

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text 1"

AutoCAD SHX Text

22-1/2 SF EDR

AutoCAD SHX Text

63-3/4 SF EDR

AutoCAD SHX Text

55 SF EDR

AutoCAD SHX Text

80-3/4 SF EDR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

35 SF EDR

AutoCAD SHX Text

35 SF EDR

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

39 SF EDR BELOW WINDOW SEAT

AutoCAD SHX Text

1" UP/DN

AutoCAD SHX Text 1"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1"

AutoCAD SHX Text 1"

AutoCAD SHX Text

2" UP/DN

AutoCAD SHX Text

45 SF EDR

AutoCAD SHX Text

56 SF EDR

AutoCAD SHX Text

43-1/4 SF EDR

AutoCAD SHX Text

20 SF EDR

AutoCAD SHX Text

12-1/3 SF EDR

AutoCAD SHX Text

18 SF EDR

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text

45 SF EDR

AutoCAD SHX Text

EXISTING STEAM RADIATOR (TYP)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text

AutoCAD SHX Text

31.5 SF EDR

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1"

AutoCAD SHX Text 1"

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXST

AutoCAD SHX Text

EXST

AutoCAD SHX Text

EXST ELEC PANEL

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

PROPOSED WET RETURN (LPC), BELOW STEP UP

AutoCAD SHX Text

EXIST CW

AutoCAD SHX Text 04/21/2021

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXST WELL WATER TANK

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TO BOILER

AutoCAD SHX Text

AutoCAD SHX Text

WATER FEEDER

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

WELL WATER TANK

AutoCAD SHX Text

WATER HEATER

AutoCAD SHX Text

OIL STORAGE TANK

AutoCAD SHX Text

CRAWL SPACE (NOT USED)

AutoCAD SHX Text

ENCLOSED OIL STORAGE

AutoCAD SHX Text

OIL STORAGE TANK

AutoCAD SHX Text V

AutoCAD SHX Text V

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text

LPC

AutoCAD SHX Text

LPC

AutoCAD SHX Text

LPS/LPC

AutoCAD SHX Text

LPC

AutoCAD SHX Text 2-1/2"

AutoCAD SHX Text 2-1/2"

AutoCAD SHX Text 2-1/2"

AutoCAD SHX Text 3"

AutoCAD SHX Text

LPC

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

PMIS/PKG NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

REHABILITATE GATEHOUSE BOILERS

AutoCAD SHX Text

JORDAN POND & BROWN MOUNTAIN

AutoCAD SHX Text

BM DEMOLITION PLAN

AutoCAD SHX Text

AutoCAD SHX Text 60,008

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DC

AutoCAD SHX Text

KC

AutoCAD SHX Text

RB

AutoCAD SHX Text

ACADIA NATIONAL PARK

AutoCAD SHX Text

ACAD241643

AutoCAD SHX Text

AutoCAD SHX Text

LEGEND:

AutoCAD SHX Text

AutoCAD SHX Text

KEY NOTES:

AutoCAD SHX Text REMOVE RADIATOR, RADIATOR VALVE, CONTROL VALVE, AND AIRVENT. SAVE RADIATOR FOR REINSTALLATION AFTER REFURBISHMENT. REMOVE EXISTING THERMOSTAT. PATCH WALL TO MATCH EXISTING. REMOVE EXISTING BOILER, CLOSE BOILER STEAM PIPING, BOILER WATER FEED SYSTEM, FUEL LINE, AND ELECTRICAL WIRING BACK TO LOCAL JB IN PREPARATION FOR NEW BOILER INSTALLATION. REMOVE BOILER VENT FROM BOILER TO CHIMNEY. REMOVE FUEL OIL PIPING, VALVES AND FILTERS, FROM TANKS TO BOILER. REMOVE FUEL FILL AND VENT PIPING. EXTERIOR AND THROUGH-WALL PIPING MAY BE REUSED. CAP UNUSED FILL/VENT OUTSIDE REMOVE 275 GALLON FUEL OIL TANKS. REMOVE WATER FEED SYSTEM SUFFICIENT FOR CONNECTION TO NEW BOILER. REMOVE END OF MAIN VENT AND PREPARE 3/4" VENT RISER FOR EXTENSION. REMOVE 1-1/2" WET RETURN (LPC) FROM DROPS NEAR STAIR, TO BOILER.

AutoCAD SHX Text BROWN MOUNTAIN GATE HOUSE BASEMENT FLOOR HEATING DEMOLITION PLAN SCALE: 3/16"=1'-0" ±

AutoCAD SHX Text

BROWN MOUNTAIN GATE HOUSE 1ST FLOOR HEATING DEMOLITION PLAN SCALE: 3/16"=1'-0" ±

AutoCAD SHX Text

BROWN MOUNTAIN GATE HOUSE 2ND FLOOR HEATING DEMOLITION PLAN SCALE: 3/16"=1'-0" ±

AutoCAD SHX Text

60 SF EDR

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

66 SF EDR

AutoCAD SHX Text

60 SF EDR

AutoCAD SHX Text

54 SF EDR

AutoCAD SHX Text

24.5 SF EDR

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text T

AutoCAD SHX Text

59.5 SF EDR

AutoCAD SHX Text T

AutoCAD SHX Text

PIPING UP PIPING DOWN CONNECT TO EXISTING THERMOSTAT END-OF-MAIN VENT

AutoCAD SHX Text

AutoCAD SHX Text

48 SF EDR

AutoCAD SHX Text

42 SF EDR

AutoCAD SHX Text

59.5 SF EDR

AutoCAD SHX Text X"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

AutoCAD SHX Text

1-1/2" UP/DN

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ABBREVIATION:

AutoCAD SHX Text SF=SQUARE FEET EDR=EQUIVALENT DIRECT RADIATION. (1 SF EDR = 240 BTU/HR) DN=DOWN FFE=FINISHED FLOOR ELEVATION CW=COLD WATER EXST=EXISTING LPS=LOW PRESSURE STEAM LPC=LOW PRESSURE CONDENSATE

AutoCAD SHX Text GENERAL MECHANICAL AND ELECTRICAL REMOVALS NOTES: : 1. AN ATTEMPT HAS BEEN MADE TO INDICATE ITEMS FOR REMOVAL. SOME ITEMS REQUIRING REMOVAL MAY INADVERTENTLY NOT BE AN ATTEMPT HAS BEEN MADE TO INDICATE ITEMS FOR REMOVAL. SOME ITEMS REQUIRING REMOVAL MAY INADVERTENTLY NOT BE SHOWN. REMOVE ALL ITEMS AS REQUIRED FOR NEW CONSTRUCTION UNLESS NOTED OTHERWISE. VERIFY EXISTING CONDITIONS IN THE FIELD. 2. ALL REMOVED ITEMS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE PREMISES, UNLESS ALL REMOVED ITEMS SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE PREMISES, UNLESS INDICATED OTHERWISE. 3. REMOVE EXISTING HEATING SYSTEM COMPONENTS AS INDICATED AND REQUIRED TO COMPLETE NEW WORK. REMOVE EXISTING HEATING SYSTEM COMPONENTS AS INDICATED AND REQUIRED TO COMPLETE NEW WORK. 4. REMOVE EXISTING EQUIPMENT ELECTRICAL CONNECTIONS AND WIRING, ETC. AS INDICATED AND REQUIRED TO COMPLETE NEW WORK. REMOVE EXISTING EQUIPMENT ELECTRICAL CONNECTIONS AND WIRING, ETC. AS INDICATED AND REQUIRED TO COMPLETE NEW WORK. REMOVE ALL UNUSED/ABANDONED ELECTRICAL AND POWER SYSTEMS COMPONENTS.

AutoCAD SHX Text GENERAL NOTES: 1. THE CONTRACTOR SHALL CONFIRM ACTUAL CONDITIONS IN THE FIELD PRIOR TO SUBMITTING A BID. THE CONTRACTOR SHALL CONFIRM ACTUAL CONDITIONS IN THE FIELD PRIOR TO SUBMITTING A BID. 2. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH LOCAL AND STATE CODES AND REGULATIONS. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH LOCAL AND STATE CODES AND REGULATIONS. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURING THAT ALL BOILER RELATED ELECTRICAL WORK MEETS CURRENT CODE CONTRACTOR SHALL BE RESPONSIBLE FOR ASSURING THAT ALL BOILER RELATED ELECTRICAL WORK MEETS CURRENT CODE REQUIREMENTS AS PART OF THIS WORK. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONNECTIONS TO NEW AND EXISTING CONTROLS AS REQUIRED FOR A COMPLETE THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONNECTIONS TO NEW AND EXISTING CONTROLS AS REQUIRED FOR A COMPLETE INSTALLATION. 5. CONTRACTOR SHALL INSTALL ALL FUEL PIPING AND REQUIRED ACCESSORIES AS INDICATED OR REQUIRED FOR COMPLETE CODE CONTRACTOR SHALL INSTALL ALL FUEL PIPING AND REQUIRED ACCESSORIES AS INDICATED OR REQUIRED FOR COMPLETE CODE COMPLIMENT SYSTEM. 6. ADJUST PIPING AS NEEDED TO CONNECT TO NEW BOILER AND MAINTAIN PROPER FLOW IN EXISTING PIPE RUNS, MATCH VALVES, ADJUST PIPING AS NEEDED TO CONNECT TO NEW BOILER AND MAINTAIN PROPER FLOW IN EXISTING PIPE RUNS, MATCH VALVES, STRAINERS, CIRCUIT SETTERS, ETC. TO DESIRED FLOW AND PIPE DIAMETER. 7. THE SCOPE OF THE PROJECT SHALL INCLUDE THE INSTALLATION OF NEW PIPING, VALVES, TANKS, SENSORS, CONTROLS, BOILER, VENT THE SCOPE OF THE PROJECT SHALL INCLUDE THE INSTALLATION OF NEW PIPING, VALVES, TANKS, SENSORS, CONTROLS, BOILER, VENT PIPING, PIPING INSULATION, ETC. 8. CONTRACTOR TO REPLACE ANY AND ALL CONTROLS THAT PERTAIN TO BOILER CONTRACTOR TO REPLACE ANY AND ALL CONTROLS THAT PERTAIN TO BOILER 9. EXISTING CONDITION SHOWN ON PLAN OBTAINED FROM HISTORICAL PLANS PROVIDED BY GOVERNMENT.EXISTING CONDITION SHOWN ON PLAN OBTAINED FROM HISTORICAL PLANS PROVIDED BY GOVERNMENT.

AutoCAD SHX Text DEMOLITION NOTES: 1. REMOVE EXISTING BOILER AND ACCESSORIES AS REQUIRED FOR INSTALLATION OF NEW BOILER. REMOVE EXISTING BOILER AND ACCESSORIES AS REQUIRED FOR INSTALLATION OF NEW BOILER. 2. CONTRACTOR IS RESPONSIBLE TO VISIT SITE AND VERIFY EXISTING CONDITIONS. CONTRACTOR IS RESPONSIBLE TO VISIT SITE AND VERIFY EXISTING CONDITIONS. 3. REMOVE EXISTING BURNER. REMOVE ANY UNUSED WIRING BACK TO ELECTRICAL PANEL. REUSE EXISTING CONDUIT AND WIRING SO FAR REMOVE EXISTING BURNER. REMOVE ANY UNUSED WIRING BACK TO ELECTRICAL PANEL. REUSE EXISTING CONDUIT AND WIRING SO FAR AS PRACTICAL AND MODIFY AS REQUIRED FOR INSTALLATION OF NEW BOILER. 4. CONTRACTOR SHALL CUT PIPING AT LOCATIONS SHOWN ON PLANS.CONTRACTOR SHALL CUT PIPING AT LOCATIONS SHOWN ON PLANS.

AutoCAD SHX Text 1'-0'

AutoCAD SHX Text

AutoCAD SHX Text 6'

AutoCAD SHX Text 6'

AutoCAD SHX Text 3'

AutoCAD SHX Text

SCALE: 3/16"=

AutoCAD SHX Text

STEEL SUPPORT POST

AutoCAD SHX Text

CONCRETE CEILING BEAM

AutoCAD SHX Text

CONCRETE CURB (6"X6")

AutoCAD SHX Text

HATCH LEGEND

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

LPC

AutoCAD SHX Text

LPS

AutoCAD SHX Text

EXST CW TO BOILER.

AutoCAD SHX Text

EXISTING WATER HEATER / WELL TANK TO REMAIN

AutoCAD SHX Text

TANKS TO BE REPLACED

AutoCAD SHX Text

AutoCAD SHX Text

BOILER TO BE REMOVED

AutoCAD SHX Text

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

CAPPED

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text V

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1"

AutoCAD SHX Text

21 SF EDR

AutoCAD SHX Text

1-1/4" UP/DN

AutoCAD SHX Text

AutoCAD SHX Text

BELOW FLOOR

AutoCAD SHX Text 04/21/2021

AutoCAD SHX Text

WELL WATER TANK

AutoCAD SHX Text

WATER HEATER

AutoCAD SHX Text

CRAWL SPACE (NOT USED)

AutoCAD SHX Text

ENCLOSED OIL STORAGE

AutoCAD SHX Text 2"

AutoCAD SHX Text V

AutoCAD SHX Text V

AutoCAD SHX Text 1"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

LPC

AutoCAD SHX Text

LPC

AutoCAD SHX Text

LPS/LPC

AutoCAD SHX Text

LPC

AutoCAD SHX Text 2-1/2"

AutoCAD SHX Text 2-1/2"

AutoCAD SHX Text 2-1/2"

AutoCAD SHX Text

FOS

AutoCAD SHX Text L-2

AutoCAD SHX Text B-1

AutoCAD SHX Text T

AutoCAD SHX Text V

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

PMIS/PKG NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

REHABILITATE GATEHOUSE BOILERS

AutoCAD SHX Text

JORDAN POND & BROWN MOUNTAIN

AutoCAD SHX Text

BM PROPOSED PLAN

AutoCAD SHX Text

AutoCAD SHX Text 60,008

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DC

AutoCAD SHX Text

KC

AutoCAD SHX Text

RB

AutoCAD SHX Text

ACADIA NATIONAL PARK

AutoCAD SHX Text

ACAD241643

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

KEY NOTES:

AutoCAD SHX Text AFTER PRESSURE TESTING AND REFINISHING, REPLACE RADIATOR IN ORIGINAL LOCATION. SHIM RADIATOR TO PITCH TO STEAM SUPPLY/CONDENSATION CONNECTION. PROVIDE THERMOSTATIC RADIATOR VALVE WITH BUILT-IN VACUUM BREAKER, AND RADIATOR SERVICE VALVE PROVIDE 7-DAY, 24-HOUR, PROGRAMMABLE THERMOSTAT. PATCH WALL WHERE EXIST THERMOSTAT WAS REMOVED TO MATCH EXISTING. PROVIDE NEW BOILER AS SCHEDULED. PROVIDE CLOSE BOILER PIPING (RISER, HEADER, EQUALIZER, HARTFORD LOOP) PER BOILER MANUFACTURER'S REQUIREMENTS; EXCEPT PROVIDE DROP HEADER, ONE PIPE SIZE LARGER THAN MANUFACTURER'S REQUIREMENTS. PROVIDE PRIMARY AND SECONDARY PROBE-TYPE LWCO; PRIMARY PRESSURE CONTROL (SET 0.5 PSI WITH 1 PSI DIFFERENTIAL) AND SECONDARY PRESSURE CONTROL (SET TO BREAK AT 10 PSI), WITH PIGTAIL, SKIM TAPPING, PRESSURE GAUGE, DRAIN VALVE, SERVICE SWITCH, AND BAROMETRIC DRAFT. PROVIDE BOILER WATER FEEDER EQUIVALENT TO HYDROLEVEL MODEL VXT-120. PROVIDE NEW 8" DIAMETER FLUE PIPE FROM BOILER TO CHIMNEY. PROVIDE NEW 3/8" SOFT L COPPER TUBE FUEL OIL LINE, IN EMT CONDUIT. PROVIDE FILTER/DEAERATOR AT BOILER; EQUIVALENT TO TIGERLOOP ULTRA MODEL S220-8. PROVIDE SCHEDULE 40 STEEL 2" DIAMETER FUEL FILL PIPING AND 1-1/2” FUEL OIL VENT, COMPLETE FUEL OIL VENT, COMPLETE WITH FILL AND VENT CAPS. EXISTING FILL AND VENT PIPING MAY BE INCORPORATED IN NEW SYSTEM. CAP UNUSED FILL AND VENT OUTDOORS. PROVIDE 275 GALLON NOMINAL CAPACITY, DOUBLE-CONTAINMENT FUEL TANKS, EQUIVALENT TO ROTH MODEL DWT 1000LH. PROVIDE BUSHINGS, VENT WHISTLES, VENT AND FILL HEADERS, DIP TUBES, LEVEL GAUGES, VISUAL LEAK INDICATORS, AND OTHER ACCESSORIES FOR A COMPLETE SYSTEM. EXISTING FILL AND VENT PIPING MAY BE INCORPORATED IN NEW SYSTEM. CAP UNUSED FILL AND VENT OUTDOORS. PROVIDE NEW BACKFLOW PREVENTER EQUIVALENT TO 1/2" WATTS MODEL 9D, AND NEW BALL VALVE. CONNECT TO NEW WATER FEEDER. EXTEND VENT RISER TO THE EXTENT POSSIBLE (6' MINIMUM, 10" PREFERRED) AND PROVIDE MAIN VENT(S) SIZED TO VENT MAIN PIPING AIR VOLUME IN 3 MINUTES AT 2 OZ PRESSURE. PROVIDE 14"H x 26"W (APPROXIMATE, FIELD VERIFY) LOUVER, EQUIVALENT TO RUSKIN MODEL ELF211. COLOR TO BE CHOSEN BY CONTRACTING OFFICER FROM STANDARD KYNAR COLORS. SIZE LOUVER TO OVERLAP EXISTING WINDOW FRAME. SEAL LOUVER FLANGE TO OUTSIDE OF EXISTING FRAME WITH BUTYL GLAZING TAPE, AND CLAMP THROUGH TO ALUMINUM TABS WITH SS SCREWS THROUGH THE LOUVER FLANGE FROM OUTSIDE, ON 8" CENTERS. DO NO PENETRATE EXISTING WINDOW FRAME WITH FASTENERS. PROVIDE 12" x 24" DUCT (WITH CENTER DIVIDER) CONNECTED TO LOUVER. SEAL WATER TIGHT AND PITCH BOTTOM BACK TO LOUVER. PROVIDE 12" W x 12" H MOTOR OPERATED DAMPER (MOD-1) IN OPEN ENDED DUCT. PROVIDE MAKE-ON-RISE THERMOSTAT AT CEILING AND CONNECT TO MOD-1. PROVIDE 12" W x 12" H DUCT, TURNED DOWN TO 12" X 6" DUCT TO WITHIN 6" OF FLOOR. PROVIDE 12" x 6" MOD-2 IN DROP DUCT. INTERLOCK MOD-2 WITH BOILER OPERATION. PROVIDE ALUMINUM BLANK OFF PLATE ADJACENT TO LOUVER TO ACCOMMODATE EXISTING DRYER VENT. MATCH LOUVER FLANGE OUTER DIMENSIONS, AND CONNECT/SEAL TO LOUVER WITH BUTYL TAPE AND ALUMINUM BACKER. PAINT TO MATCH LOUVER.

AutoCAD SHX Text

BROWN MOUNTAIN GATE HOUSE BASEMENT FLOOR HEATING PLAN SCALE: 3/16"=1'-0" ±

AutoCAD SHX Text

BROWN MOUNTAIN GATE HOUSE 1ST…