Attachment J1a - DWH Drawings.pdf

PDF 5 MB Posted

Attached to
David Wayne Hooks (DWH) REPAIR TOWER AND BASE BUILDING WATER DAMAGE CAUSED BY HURRICANE HARVEY
Solicitation number
Not on record
Issued by

About this file

This package of documents defines the scope of work for repairs to the air traffic control tower and base building at David Wayne Hooks Memorial Airport in Houston, Texas due to water damage from Hurricane Harvey. The Federal Aviation Administration is seeking contractors to repair the tower, cab, and base building, replace damaged ceilings, lights, flooring, and remove and replace plumbing in the tower shower. Drawings and specifications are provided to guide electrical, mechanical and architectural repairs. The pre-bid site visit is mandatory due to construction scope. Work hours will be coordinated to avoid impacts to air traffic operations, and all work must comply with FAA standards and specifications.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

For the best experience, open this PDF portfolio in

Acrobat X or Adobe Reader X, or later.

Get Adobe Reader Now!

http://www.adobe.com/go/reader

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

REV DESCRIPTION JCN

DATE

REDLINE

APVD

SUBMITTED BY APPROVED BY

JCN

DRAWN

CHECKED

REV

ISSUED BY

H

G

F

E

D

C

B

A

8 1234567

DRAWING NO

DESIGNED

REVIEWED BY

/2

:3

:4

M P lo tt e d b y S

R V

-C

-E

O

APPROVED

w h -d -a tc t-e .d g

8 234567

TRANSFORMER

WATERTIGHT

WEATHERPROOF

WIREGUARD

WATT

VOLT-AMPERE

VOLT

UNINTERRUPTIBLE POWER SUPPLY

UNDERWRITERS LABORATORY

UNDERGROUND

TYPICAL

TOWER

TRANSIENT VOLTAGE SURGE PROTECTION

TELCO TERMINAL BOARD

TERMINAL BLOCK

SWITCHBOARD

SWITCH

STAINLESS STEEL

SIGNAL REFERENCE GROUND GRID

SINGLE POINT GROUND

SECONDARY

ROOM

RAPID START

ROOT MEAN SQUARE

RIGID METAL CONDUIT

RECEPTACLE

POLYVINYL CHLORIDE

POTENTIAL TRANSFORMER

PRIMARY

PHASE

POWER FACTOR

PULL BOX

POLE

OVERLOAD

OWNER FURNISH & OWNER INSTALL

NOT TO SCALE

NON-TRIP

NORMALLY OPEN - DE-ENERGIZED

NATIONAL ELECTRICAL MNFGR'S ASSOC.

NATIONAL ELECTRICAL CODE - NFPA 70

NORMALLY CLOSED - DE-ENERGIZED

NEUTRAL

MICROWAVE OVEN

MULTIPLEXER

MULTIPOINT GROUND

MAIN LUGS ONLY

METAL HALIDE

MAIN DISTRIBUTION PANEL

MOTOR CONTROL CENTER

LOCAL AREA NETWORK

KILOWATT HOUR

KILOWATT

KILO-VOLT-AMP

KILOVOLT

THOUSAND CIRCULAR MILS

JB

HZ

HV

HPS

HP

HOA

HID.

HH

G/R

G/Y

G/O

GI

GRS

GFIP

GFE

GFR

GFCI

FSD

FMC

FLA

FACP

FA

EMT

E/G

DWG

DISC.

DC

CU

COMM

CCT

CFCI

CCMS

CB

BRITE

BKBD

BFG

BFF

BC

BATT.

AWG

AUX

AUTO.

ATS

ATC

ASR

ARTS

AIC

AFG

AFF

AF

AC

NOTE : ALL ABBREVIATIONS NOT NECESSARILY USED

XFMR

WT

WP

WG

W

VA

UPS

UL

UG

TYP

TWR

TVSS

TTB

TB

SWBD

SW

SS

SRGG

SPG

SEC

RM

RS

RMS

RMC

REC

PVC

PT

PRI

PH

PF

PB

OL

OFOI

NTS

NT

N.O.

NEMA

NEC

NC

N

MW

MUX

MPG

MLO

MH

MDP

MCC

LAN

KWH

KW

KVA

KV

KCM

JUNCTION BOX

HERTZ

HIGH VOLTAGE

HIGH PRESSURE SODIUM

HORSEPOWER

HAND-OFF-AUTOMATIC

HIGH INTENSITY DISCHARGE

HAND HOLE

GREEN INSULATION WITH RED TRACER

GREEN INSULATION WITH YELLOW TRACER

GREEN INSULATION WITH ORANGE TRACER

GREEN INSULATED

GALVANIZED RIGID STEEL (CONDUIT)

GROUND FAULT INTERRUPTION PROTECTION

GOVERNMENT FURNISHED EQUIPMENT

GROUND FAULT RELAY

FAULT CIRCUIT INTERRUPTER

GROUND

FIRE SMOKE DAMPER

FLEXIBLE METAL CONDUIT

FULL LOAD AMPERES

FIRE ALARM CONTROL PANEL

FIRE ALARM

FUSE

ELECTRICAL METALLIC TUBING

ENGINE GENERATOR

DRAWING

DISCONNECT

DIRECT CURRENT

COPPER

COMMUNICATIONS

CIRCUIT

CONTRACTOR FURNISHED AND INSTALLED

CENTRAL CONTROL MONITORING SYSTEM

CIRCUIT BREAKER

CONDUIT

BRIGHT RADAR INDICATOR

BACKBOARD

BELOW FINISHED GRADE

BELOW FINISHED FLOOR

BARE COPPER

BATTERY

AMERICAN WIRE GAUGE

AUXILIARY

AUTOMATIC

AUTOMATIC TRANSFER SWITCH

AIR TRAFFIC CONTROL

AIRPORT SURVEILLANCE RADAR

AUTOMATED RADAR TERMINAL SYSTEM

AMPS INTERRUPTING CAPACITY

ABOVE FINISHED GRADE

ABOVE FINISHED FLOOR

AMPS - FRAME

ALTERNATING CURRENT

AMPERES

THERMOSTAT

HANDICAPPED DOOR OPERATOR

NOTE : ALL SYMBOLS NOT NECESSARILY USED

ELECTRICAL PANEL

FEEDER DESIGNATION

DUPLEX RECEPTACLE

GROUND FAULT CIRCUIT INTERRUPTING RECEPTACLE

TWIST-LOCK RECEPTACLE

FLOOR OUTLET WITH DEVICE INDICATED

EQUIPMENT CONNECTION

DISCONNECT SWITCH & EQUIPMENT CONNECTION

MOTOR STARTER

MOTOR

JUNCTION BOX

J 8" x 8" JUNCTION BOX

ELECTRICAL DISTRIBUTION PANEL

DOUBLE DUPLEX RECEPTACLE

GFI

J

T

14.

13.

12.

11.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

DWH-D-ATCT-E015

DWH-D-ATCT-E014

DWH-D-ATCT-E013

DWH-D-ATCT-E012

DWH-D-ATCT-E011

DETAILS, ELECTRICAL

CAB & CAB ROOF LEVEL PLANS, ELECTRICAL

FLOOR PLANS, ELECTRICAL

FIRST FLOOR PLAN ELECTRICAL

DRAWING LIST, SYMBOL LEGEND AND ABBREVIATIONS

DISCONNECTS, PRINT LABELS AND AFFIX THEM ON DISCONNECTS ETC.

CONTRACTOR SHALL CALCULATE THE ARC FLASH LEVEL ON ALL NEW

HVAC EQUIPMENT.

CONTRACTOR SHALL WRITE LOCKOUT TAGOUT PROCEDURES FOR ALL NEW

LABELS FOR ALL PANELS WHETHER WORKED ON OR NOT.

CONTRACTOR SHALL PROVIDE TYPED PANEL DIRECTORIES AND IDENTIFYING

USED RIGID STEEL CONDUITS IN THE MECHANICAL AND ELECTRICAL ROOMS.

SERVICING THE TOWER.

OF THE FIRE ALARM SYSTEM. CONTACT THE FIRE ALARM COMPANY

DEVICES ARE PLACED THE CONTRACTOR SHALL DO A COMPLETE TEST

AFTER ALL THE ELECTRICAL WORK IS COMPLETE AND ALL FIRE ALARM

IN THE WORK AREA SHALL HAVE DUST COVERS DURING WORK.

ALL FIRE ALARM SMOKE DETECTORS, CONTROLLERS ETC. SMOKE DETECTORS

CONTRACTOR SHALL REMOVE AND REINSTALL APPROPRIATELY AND RECONNECT

PROVIDE A PLAN FOR APPROVAL.

TRADES TO SEE HIS SEQUENCE WOULD NOT AFFECT OTHER TRADES.

THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER

ON/OFF WITHOUT FAA TECHNICIAN BEING PRESENT.

FITS IN EXISTING SPACES. THE CONTRACTOR SHALL NOT TURN ANY BREAKER

CONTRACTOR'S RESPONSIBILITY TO ASSURE THAT ALL NEW EQUIPMENT

CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS. IT SHALL BE THE

THERE SHALL BE NO WORK DONE DURING THE FAA MORATORIUM DATES.

REQUIREMENTS.

FOR CLEANUP. THIS SCHEDULE SHALL CHANGE ACCORDING TO AIR TRAFFIC

TO 6:00 AM. WORK SHALL BE COMPLETED BY 5:30 AM LEAVING 30 MINUTES

AND ANY TYPE OF POWER INTERRUPTION SHALL BE DONE FROM 12:00 PM

ALL ELECTRICAL WORK INVOLVING TURNING OFF OF PANELS, CUT OVERS

LATEST REGULATIONS AND SUBMIT A MANIFEST TO THAT AFFECT TO FAA.

CONTRACTOR SHALL DISPOSE OFF ALL LIGHT FIXTURES ACCORDING TO

REQUIRED FOR CONNECTING THESE LIGHTS.

TO EXISTING CIRCUITS. PROVIDE ANY ADDITIONAL CONDUIT AND WIRE

THE LIGHTING FIXTURE SCHEDULE AND FLOOR PLANS. CONNECT LIGHTS

CONTRACTOR TO PROVIDE AND INSTALL ALL LIGHT FIXTURES SHOWN IN

CODES.

FAA-STD-1217G, FAA-STD-019F LATEST EDITION OF NEC AND ALL LOCAL

ALL ELECTRICAL WORK SHALL BE DONE ACCORDING TO FAA STANDARDS

THE BASIS OF DESIGN FOR THIS DISTRIBUTION SYSTEM IS SQUARE D.

ELECTRICAL GENERAL NOTES:

SYMBOL LEGEND

POWER

ELECTRICAL DRAWING LISTABBREVIATIONS

IS

U

11/30/2019

THOMAS R. CLAYTON

MGR: ENGINEERING - FORT WORTH

AA

HOUSTON

ADWH-D-ATCT-E011

ATCT

HURRICANE HARVEY WATER DAMAGE REPAIRS

DRAWING LIST, SYMBOL LEGEND

AND ABBREVIATIONS

-a tc t-e

TERMINAL

ENGINEERING SERVICES

ATO - TECHNICAL OPERATIONS CENTRAL SERVICE AREA

-B

IL

DAVID WAYNE HOOKS MEMORIAL AIRPORT

THIS DRAWING PRODUCED ON ASW REGION CAD SYSTEM

AZIZ ABBAS

PROJECT ENGINEER

1705988

A 08/24/2023 DESCOPED REVISIONS-AS BUILT 1705988 09/15/2023 JV

TX

dwh-d-atct-e011

TYPE DESCRIPTION MANUFACTURER

2' x 4' RECESSED LED FIXTURE

LIGHTING FIXTURE SCHEDULE

NOTE:

1. CONTRACTOR TO VERIFY ALL QUANTITIES, VOLTAGES, PART NUMBERS AND TRIMS.

DOOR LED LIGHT

2' x 4' SURFACE LED FIXTURE

COLUMBIA

COLUMBIA

RIVERPATH 23" LED 49946OZLED (BRONZE)

LEPC-24-35MLG-LL-EU

LEPC-24-35MLSM-LL-EUB

C COLUMBIA LEPC-14-35MLG-LL-EUC

D 1' x 4' SURFACE LED FIXTURE COLUMBIA LEPC-14-35MLSM-LL-EU

PART NUMBER

1' x 4' RECESSED LED FIXTURE

RECESSED LED FIXTURE LOTUS LED LIGHTS

OF CEILING

TRIM TO MATCH COLOR

LD4S-30K-4S-SR-BT

LD4S-30K-4S-SR-WT

H SUPERBRIGHT LED VTWJ-X20JAR TYPE LIGHT FIXTURE

J LENSED STRIPLIGHT COLUMBIA LCL4-35ML-EU

2 2

3 3

FACP

JJJ

D C

DC FACP

BASE BUILDING

LINK

LINK CORRIDOR TO BASE BUILDING

CEILING FAN LOCATIONS

SCALE: 1/4" = 1'-0"

REFLECTED CEILING PLAN BASE BUILDING

FIRST FLOOR LINK

LIGHTING PLAN FIRST FLOOR ATCT

:5 lo tt e

-a tc t-e

ENTIRE BASE BUILDING AND TOWER LINK.

REPLACE ONLY NON WORKING LIGHT FIXTURES AT THE

EDITION OF NEC AND ALL LOCAL CODES.

FAA STANDARD FAA-STD-1217G, FAA STD-19F, LATEST

ALL ELECTRICAL WORK SHALL BE DONE ACCORDING TO

SYMBOLS, ELECTRICAL DRAWING LIST AND ABBREVIATIONS.

SEE DRAWING DWH-D-ATCT-E011 FOR GENERAL NOTES,

SEALED BY THE CONTRACTOR WHO HAS CURRENT ROOF WARRANTY.

E014 AND DETAILS 2/E015, 3/E015 AND 7/E015. THE ROOF SHALL BE

ELECTRODE SYSTEM. SEE LIGHTNING PROTECTION NOTES ON SHEET

CADWELD IT TO THE NEAREST GROUND ROD OF EXISTING EARTH

ROUTE IT OUTSIDE NEAR THE CORNER OF THE BUILDING AND

THROUGH THE BUILDING. INSTALL A NEW MAIN DOWN CONDUCTOR,

REMOVE THE LIGHTENING PROTECTION DOWN CONDUCTOR GOING

INSTALL TWO LUTRON DIMMERS ONE FOR THREE LIGHTS.

LED LIGHT FIXTURE SEE LIGHTING FIXTURE SCHEDULE THIS SHEET.

USE EXISTING SWITCH/CONTROLS.

DOOR LIGHT FIXTURE. SEE LIGHTING FIXTURE SCHEDULE THIS SHEET.

HANG AT 12 FEET AFF.

ON THIS SHEET FOR DETAILS. PROVIDE WITH HANGING OPTIONS.

LENSED LIGHT FIXTURE. SEE LIGHTING FIXTURE SCHEDULE

BRACKETS ETC. TO INSTALL DUE TO TYPE OF CEILINGS.

THIS SHEET FOR DETAILS. THESE LIGHTS WILL NEED ADDITIONAL

1X4 LIGHT FIXTURE. SEE LIGHTING FIXTURE SCHEDULE ON

FOR DETAILS

INSTALL 2x4 LIGHT FIXTURE SEE LIGHTING FIXTURE SCHEDULE

4' 8'04'

GENERAL NOTES:

NOTES BY SYMBOL:

ADWH-D-ATCT-E012

FIRST FLOOR PLAN

ELECTRICAL

-a tc t-e

A 08/24/2023 DESCOPED REVISIONS-AS BUILT 1705988 09/15/2023 JV

dwh-d-atct-e012

(TYP)

EEE

E E E

NATCA

B B

A A

C C

FF F

J J s

SF-1

SECOND LEVEL PLAN ELECTRICAL

THIRD LEVEL PLAN ELECTRICAL

JUNCTION LEVEL FLOOR PLAN ELECTRICAL

:1 lo tt e

-a tc t-e

TOWER SHAFT.

REPLACE ONLY NON WORKING LIGHT FIXTURES IN

SCHEDULE.

SEE DRAWING DWH-D-ATCT-E012 FOR LIGHTING FIXTURE

ABBREVIATIONS.

SYMBOLS, ELECTRICAL DRAWING LIST, AND

ROW OF DOWN LIGHTS.

DETAILS. PROVIDE AND INSTALL ONE LUTRON DIMMER FOR EACH

LED DOWN LIGHT FIXTURE. SEE LIGHTING FIXTURE SCHEDULE FOR

BY MECHANICAL CONTRACTOR. SEE MECHANICAL SCHEDULES.

INSTALL SWITCHES FOR VANITY LIGHT, HEATER AND FAN SUPPLIED

DRAWING DWH-D-ATCT-E012 FOR DETAILS.

1x4 RECESSED LIGHT FIXTURE. SEE LIGHTING FIXTURE SCHEDULE

DRAWING DWH-D-ATCT-E012 FOR DETAILS.

2x4 SURFACE LIGHT FIXTURE. SEE LIGHTING FIXTURE SCHEDULE ON

#54105 BLACK COLOR. COORDINATE LOCATION WITH AIR TRAFFIC/SSC.

FAN CASABLANCA FAN CO. 54" CALEDONIA, LOW PROFILE MODEL

REPLACE EXISTING CEILING FAN WITH COMMERCIAL GRADE CEILING

SCHEDULE ON DRAWING DWH-D-ATCT-E012 FOR DETAILS.

INSTALL 2x4 RECESSED LIGHT FIXTURE SEE LIGHTING FIXTURE

ADWH-D-ATCT-E013

HURRICANE HARVEY WATER DAMAGE REPAIR

FLOOR PLANS

-a tc t-e

THIS DRAWING PRODUCED ON ASW REGION MICROSTATION SYSTEM

A 08/23/2023 DESCOPED REVISIONS AS-BUILT 1705988 09/15/2023 JV

dwh-d-atct-e013

10 TYP OF 4.

HANDRAIL

RING. ON CATWALK

EQUALIZATION

POTENTIAL

SEE DETAIL9/E015

TYP OF 4 PLACES.

AHU

ON FIRST FLOOR

TO PANEL 'MDP'

3#3, #10 G, 1 1/2"C

CAB FLOOR PLAN ELECTRICAL

CAB ROOF PLAN ELECTRICAL

CAB ROOF AND CAT WALK LEVEL LIGHTNING PROTECTION

:2 lo tt e

-a tc t-e

SCHEDULE.

SEE DRAWING DWH-D-ATCT-E012 FOR LIGHTING FIXTURE

SYMBOLS, ELECTRICAL DRAWING LIST AND ABBREVIATIONS.

ON/OFF SWITCH. ADD DIMMER FOR NEW CAN LIGHTS HERE.

REPLACE FOUR EXISTING DIMMERS WITH LUTRON DIMMERS WITH

TO THE FOUR MAIN DOWN CONDUCTORS. SEE DETAIL 9/E015.

CONNECT THE CATWALK HANDRAIL POTENTIAL EQUALIZATION RING

PARAPET COUNTERPOISE WITH A MINIMUM OF #2 AWG.

BOND THE ROOF TOP UNIT ON TWO OPPOSITE SIDES WITH THE CAB

SEE DETAIL 9/E015.

FOUR DOWN CONDUCTORS FROM THE LIGHTNING AIR TERMINALS.

ALL MATERIAL SHALL BE CLASS I. CONNECT THE COUNTERPOISE TO

PLACE A COUNTERPOISE ON THE SECOND RAIL OF THE CAB PARAPET.

COUNTERPOISE SEE DETAIL 1/E015 AND 7/E015.

GROUND ROD AND EXOTHERMICALLY WELD TO THE EXISTING

GROUND ROD CANNOT BE LOCATED INSTALL A 3/4"x10'-0" COPPER

THE EXISTING TOWER COUNTERPOISE. TYPICAL OF 4. IF EXISTING

EXISITNG GROUND ROD THAT IS EXOTHERMICALLY WELDED TO

CONDUCTOR SHALL ENTER THE GROUND AND BE WELDED TO AN

NO LESS THAN 18" ABOVE GROUND LEVEL. THE 4/0 AWG COPPER

CONDUCTOR BY BURNDY YGHC-C PRIOR TO ENTERING GROUND AT

DOWN CONDUCTORS SHALL BE CONNECTED TO 4/0 AWG COPPER

THE TOWER CAB METAL STRUCTURE.

IN PVC SCHEDULE 40 CONDUIT WHERE IT COMES IN CONTACT WITH

THRU THE GRATE. SEE DETAIL 9/E015. DOWN CONDUCTOR SHALL BE

THE GRATE AT FOUR PLACES WHERE THE DOWN CONDUCTORS PASS

CONDUCTOR SHALL PASS THRU THE CATWALK GRATE FLOOR. BOND

OF THE TOWER AND SHALL BE SUPPORTED EVERY 3 FEET. THE DOWN

CONDUCTOR FROM THE LIGHTNING ROD DOWN TO THE EXTERIOR

5/E015 AND 9/E015. RUN CLASS II MAIN COPPER LIGHTNING DOWN

AND INSTALL A 1/2"x3'-0" LIGHTNING TERMINAL ON TOP. SEE DETAILS

INSTALL A NEW 15 FOOT 2 1/2" OR 3" (MATCH EXISTING) GI PIPE POST

BREAKER FOR THE NEW ROOF TOP UNIT.

PANEL 'A' ON THE GROUND FLOOR WITH A 3P-60 AMP HACR TYPE

REPLACE THE EXISTING BREAKER FOR THE ROOF TOP UNIT IN

AFFIX ARC FLASH LABEL.

ON THE UNIT AS SHOWN FOR THE ROOF TOP UNIT. PRINT AND

NEMA 4X STAINLESS STEEL HEAVY DUTY DISCONNECT MOUNTED

PROVIDE POWER TO SQUARE D 3P-60 AMP, NON FUSED,

BEEN REPLACED.

FIXTURES IN THE CAB CEILING AFTER THE CEILING GRID HAS

REINSTALL THE EXISTING COOPER LIGHTING PINHOLE LIGHT

WITH AIR TRAFFIC/SSC.

PROFILE MODEL # 54105 BLACK COLOR. COORDINATE LOCATION

CEILING FAN CASABLANCA FAN CO. 54" CALEDONIA, LOW

REPLACE ONE EXISTING CEILING FAN WITH COMMERCIAL GRADE

EXISTING 1x4 LIGHT FIXTURE.

SWITCH FOR THESE FIXTURES. USE SAME CIRCUIT AS THE

FIXTURE SCHEDULE. PROVIDE AND INSTALL NEW DIMMER

INSTALL TWO LED DOWN LIGHT FIXTURES 'E'. SEE LIGHTING

REMOVE 1x4 LIGHT FIXTURE.

REPLACE RECEPTACLE WITH A WEATHERPROOF GFCI RECEPTACLE.

JAR TYPE LIGHT FIXTURE 'H', SEE LIGHTING FIXTURE SCHEDULE.

REPLACE EXISTING JAR TYPE FIXTURE WITH A NEW LED

ONLY BE USED FOR UNDERGROUND I.E. ON GROUND RODS.

WITH BURNDY TYPE YGHC-C HYTAP CONNECTORS. EXOTHERMIC WELDS SHALL

ALL ABOVE GROUND LIGHTNING PROTECTION CONNECTIONS SHALL BE DONE

REFER TO DWG DWH-D-ATCT-E15 FOR DETAILS.

PROVIDE A TOTAL OF FOUR DOWN CONDUCTORS FOR TOWER.

WITH APPLICABLE CODE REQUIREMENTS INCLUDING FAA-STD-19F.

DIMENSIONS AND SITE CONDITIONS AND PROVIDE SYSTEMS THAT COMPLY

INTENDED TO SHOW BASIC SYSTEM DESIGN. CONTRACTOR SHALL VERIFY

THE DESIGN SHOWN FOR THESE SYSTEMS ARE SCHEMATIC AND ARE

BE BONDED TO THE SYSTEM IN ACCORDANCE WITH UL96A REQUIREMENTS.

METAL BODIES WITHIN 6'-0" OF THE LIGHTNING PROTECTION SYSTEM SHALL

GUARDS SHALL EXTEND 6'-0" ABOVE AND 1'-0" BELOW GRADE LEVEL.

1" SCHEDULE 80 PVC GUARDS SHALL BE PROVIDED FOR DOWN CONDUCTORS.

LESS THAN 8 INCHES.

ANGLE OF LESS THAN 90 DEGREES, NOR SHALL IT HAVE A BEND RADIUS OF

NO BEND IN A MAIN OR BONDING CONDUCTOR SHALL FORM AN INCLUDED

DOWN CONDUCTORS SHALL FOLLOW THE MOST DIRECT DOWNWARD COURSE.

AS DEFINED BY NFPA 780 UNLESS OTHERWISE SHOWN.

AND BONDING) SHALL BE CLASS I MAIN SIZED COPPER CONDUCTORS

ALL CONDUCTORS USED IN LIGHTNING PROTECTION SYSTEM (MAIN

SURFACES.

SURFACES. ALUMINUM COMPONENTS ONLY SHALL BE USED ON ALUMINUM

COPPER LIGHTNING COMPONENTS SHALL NOT BE MOUNTED ON ALUMINUM

WITH ALL FAA STANDARDS INCLUDING FAA-STD-19F.

INSTALLATION SHALL EXCEED NFPA 780 REQUIREMENTS AND COMPLIES

COMPLETION.

UL MASTER LABEL SHALL BE FURNISHED TO THE OWNER UPON

OF UNDERWRITERS LABORATORIES - LATEST EDITION. THE

REQUIREMENTS FOR LIGHTNING PROTECTION SYSTEMS, UL96A"

THE COMPLETED INSTALLATION SHALL MEET THE "INSTALLATION

12.

LIGHTNING PROTECTION NOTES:

ADWH-D-ATCT-E014

CAB & CAB ROOF FLOOR PLANS

-a tc t-e dwh-d-atct-e014

NOTE 1 (TYP)

USE CADWELD TYPE "GY"

FOR ADDITIONAL CONNECTIONS

CADWELD TYPE "GT".

CABLE

PROVIDE SEAL AROUND

RIGID PVC CONDUIT.

2" SCHEDULE 80

PER 1000')

14 AWG WIRES - 375 LBS.

CONDUCTOR (28 STRANDS OF

COPPER LIGHTNING

NO. 10-28C, CLASS II

EVERY 3'-0" MAX.

CABLE FASTENER

COPPER ADHESIVE

NO. 50-262C,

NO.10-28C, CLASS II

PIPE CLAMP

NO.40-354C, TINNED BRONZE

VERTICAL BASE

NO.30-12CVERT, BRASS

50H2

LBS. PER 1000')

OF 14 AWG WIRES - 375

CONDUCTOR (28 STRANDS

NO. 10-28C, CLASS II

HL

H250

ALL DETAILS NOT NECESSARILY APPLICABLE.

ALL AIR TERMINALS SHALL BE SHARP TIP TYPE.

TO PREVENT MOISTURE SEEPAGE PAST THE CONDUIT OR SEAL.

INSTALLED USING WATERPROOFING TREATMENT AND MATERIALS

ALL CONDUITS AND SLEEVES PENETRATING FLOORS SHALL BE

TYPE OR APPROVED EQUAL.

CADWELD OR THOMPSON CATALOG NUMBERS ARE INDICATIVE OF

TYPICAL OF 4

NEW 15'-0" GI AIR TERMINAL SUPPORT.

HYTAP CONNECTORS

BURNDY TYPE YGHC-C

HYTAP CONNECTORS

BURNDY TYPE YGHC-C

SYMBOL

CABLE

THROUGH

CONDUCTOR TO EES

4/0 AWG COPPER

EXOTHERMICALLY WELD

BUILDING

CABLE AWAY FROM THE

SUPPORT TO HOLD THE

SURFACES. PROVIDE CABLE

CABLE TO ANY ALUMINUM

DO NOT ATTACH COPPER

NOTE 1, (TYP)

CAT NO. 246

THOMPSON

GROUND GUARD

GROUND LEVEL

AT NOT LESS THAN 18" ABOVE

COPPER GROUND CONDUCTOR

CAT. NO. 28R TO A 4/0 AWG

COPPER CABLE THOMPSON

CONNECTOR TO CONNECT

USE BURNDY YGHC-C TYPE

HYTAP CONNECTOR

USE BURNDY YGHC-C TYPE

NO.10-28C, CLASS II

ON THE MULLION

RUN THE DOWN CONDUCTOR

TYPICAL OF FOUR PLACE

THE CATWALK GRATE FLOOR

THE MAIN DOWN CONDUCTOR UNDER

EQUALIZATION RING ON THE RAIL TO

CONNECT THE CATWALK POTENTIAL

SUPPORT EVERY THREE FEET

ON THE SIDE OF THE TOWER

RUN THE DOWN CONDUCTOR

AIR TERMINAL

ON BASE BUILDING ROOF

EXISTING AIR TERMINAL

THROUGH CABLE

3/4"x10'-0" COPPER CLAD ROD

SYMBOL

COPPER AIR TERMINAL

SHARP TIPPED SOLID

NO.20-5824C, 5/8"x3'-0"

CATWALK GUARD RAIL

COPPER AIR TERMINAL

SHARP TIPPED SOLID

NO.20-5824C, 5/8"X24"

FASTENERS

WITH STAINLESS STEEL

UNIVERSAL BASE MOUNTED

NO.30-12CU, BRONZE

IN

L

STRAP TYPE PIPE CLAMP

NO.40-XXXC, TINNED BRONZE

CABLE TO FLAT METAL CLAMP

NO.40-213C, BRONZE

CONNECTOR

NO.40-211BM, BIMETAL BRONZE BONDING PLATE

NO.40-217CT, TINNED

GROUND ROD DETAIL

E015

AIR TERMINAL SUPPORT

CAB ELEVATION

MAIN CONDUCTOR SUPPORT

AIR TERMINAL SUPPORT

MAIN CONDUCTOR PASSING THRU PARAPET

DETAIL

DETAIL

TYPICAL BONDING DETAILS

NOTES:

:0 lo tt e

-a tc t-e

ADWH-D-ATCT-E015

DETAILS

-a tc t-e dwh-d-atct-e015

:5 lo tt e

-a tc t-g

HOUSTON, HARRIS COUNTY, TEXAS

AIR TRAFFIC CONTROL TOWER AND BASE BUILDING

HURRICANE HARVEY WATER DAMAGE REPAIR

Y

E R Y

LEN

ILLO

R E A U X

R

IR

EAGLE LN

THORA RD

T OF TRANSPO

T A

IO

IC

OF

STATES

IT

TM

EN

AVIA

LAR

TRAT

SI

NI

VICINITY MAP

07/27/2019

ADWH-D-ATCT-G008

CC

SP

COVER SHEET AND VICINITY MAP

-a tc t-g

SAMUEL PEREZ

A 08/24/2023 DESCOPED REVISIONS AS-BUILT 1705988 09/15/2023 JV

dwh-d-atct-g008 lo tt e

-a tc t-g

A004

A002

A001

A001

GENERAL NOTES: SYMBOLS LEGEND MATERIALS LEGEND

MINERAL/CERAMIC WOOL

ACOUSTICAL CEILING TILE

STEEL

ALUMINUM

BLANKET INSULATION

FIRE-STOP MORTAR

GYPSUM BOARD

PLYWOOD

EXISTING CONSTRUCTION TO REMAIN

NEW FIRE RATED PARTITION

PLYWOOD FLOOR

OR DEMOLITION

NEW CONSTRUCTION

FIRE EXTINGUISHER

PARTITION TYPE

DOOR NUMBER

NOTE NUMBER

DETAIL IS DRAWN

SHEET ON WHICH

OR LETTER

DETAIL INDICATION

WALL SECTION IS DRAWN

DETAIL NUMBER

WALL SECTION NUMBER

WALL SECTION INDICATION

ELEVATION IS DRAWN

ELEVATION NUMBER

ELEVATION INDICATION

SECTION IS DRAWN

BUILDING SECTION INDICATION

SECTION NUMBER

PERMITS, LICENSES AND TAXES

ENVIRONMENTAL PROTECTION

THE CONTRACTOR SHALL COMPLY WITH ALL FEDERAL, STATE AND LOCAL LAWS

AND REGULATIONS CONTROLLING POLLUTION OF THE ENVIRONMENT. HE

SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT POLLUTION OF STREAMS,

LAKES, PONDS, AND RESERVOIRS WITH FUELS, OILS, BITUMENS, CHEMICALS

OR OTHER HARMFUL MATERIALS AND TO PREVENT POLLUTION OF THE ATMOSPHERE

FROM PARTICULATE AND GASEOUS MATTER.

SANITARY, HEALTH AND SAFETY PROVISIONS

THE CONTRACTOR SHALL PROVIDE AND MAINTAIN IN A NEAT, SANITARY CONDITION

SUCH ACCOMMODATIONS FOR THE USE OF HIS EMPLOYEES AS MAY BE NECESSARY TO

COMPLY WITH THE REQUIREMENTS OF THE STATE AND LOCAL BOARD OF HEALTH, OR

ATTENTION IS DIRECTED TO FEDERAL, STATE AND LOCAL LAWS, RULES AND

REGULATIONS CONCERNING CONSTRUCTION SAFETY AND HEALTH STANDARDS. THE

CONTRACTOR SHALL NOT REQUIRE ANY WORKER TO WORK IN SURROUNDINGS OR UNDER

CONDITIONS WHICH ARE UNSANITARY, HAZARDOUS OR DANGEROUS TO HIS HEALTH OR

SAFETY.

UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL REMOVE FROM THE SITE ALL

EMPLOYED BY HIM.

SURPLUS MATERIALS, AND EQUIPMENT BELONGING TO HIM, OR SUBCONTRACTORS

OTHER JURISDICTIONS.

THE CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT, MATERIALS AND

INSTALLATION WORK ARE COORDINATED WITH AND ARE COMPATIBLE WITH THE

ARCHITECTURAL, ELECTRICAL, AND CIVIL PLANS.

WORKING HOURS. THIS CONSISTS OF ELECTRICAL, AND OTHER UTILITIES.

ANY CONSTRUCTION PURPOSE. PARTIAL WORK SHALL BE INSTALLED AFTER NORMAL

BIDDING. ELECTRICAL SERVICE SHALL NOT BE SHUT DOWN OR INTERRUPTED FOR

SITE VISIT IS MANDATORY DUE TO NUMEROUS CONSTRUCTION ITEMS PRIOR TO

WORK WILL NOT BE ALLOWED TO INTERFERE WITH AIR TRAFFIC

CAB HOURS OF OPERATION ARE 7 A.M. TO 10 PM.

OPERATIONS. WORK IN THE CAB SHALL BE PERFORMED FROM 10:15 PM TO 6:15 A.M.

9125 BOUDREAUX ROAD TOMBALL, TEXAS 77379

COORDINATING AGENCIES

ATCT ADDRESS

CONTROL TOWER. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL,

EQUIPMENT AND TRANSPORTATION NECESSARY TO CONSTRUCT ALL ELEMENTS OF A

COMPLETE FACILITY AS SHOWN IN THE PLANS, INCLUDING, BUT NOT LIMITED TO,

THE FOLLOWING:

ALL WORK SHALL BE COORDINATED THROUGH CONTRACTING OFFICE REPRESENTATIVE SO

NOT TO DISRUPT OPERATIONS OF THE CONTROL TOWER.

B. ALL OTHER MISCELLANEOUS ITEMS SHOWN ON THE DRAWING OR

DESCRIBED IN THE SPECIFICATIONS.

EXPEDITIOUS AND DILIGENT PERFORMANCE OF THE WORK.

FEES, AND TAXES AND GIVE ALL NOTICES NECESSARY FOR THE LAWFUL,

THE CONTRACTOR SHALL OBTAIN ALL PERMITS AND LICENSES, PAY ALL CHARGES,

THESE DRAWINGS DEFINE THE WATER DAMAGE REPAIRS AT AN AIRPORT TRAFFIC

A. REPAIR TOWER AND BASE BUILDING WATER DAMAGE CAUSED BY HURRICANE HARVEY.

3. AT MANAGER - KENNETH RODRIGUEZ (281) 376-7309

2. DWH SSC MANAGER - PATRICIA NAVARRO (281) 784-7661

1. FAA REPRESENTATIVE - JENNIFER VANDENBROOK (224) 545-1575

DRAWING NUMBERS TITLE

INDEX OF DRAWINGS

DWH-D-ATCT-G008

DWH-D-ATCT-G009

DWH-D-ATCT-A014

DWH-D-ATCT-A016

SW-D-9229-A1

SW-D-9229-A2

D-6208A A-1

D-6208A A-5

DWH-D-ATCT-E011

DWH-D-ATCT-E012

DWH-D-ATCT-E013

DWH-D-ATCT-E014

COVER SHEET AND VICINITY MAP

INDEX OF DRAWINGS, SYMBOLS/MATERIALS LEGENDS AND GENERAL NOTES

CAB ROOF PLAN

CAB ROOF PLANS AND BASE BUILDING DETAILS

TOWER FLOOR PLANS

CAB FLOOR, WINDOW, CEILING AND ROOF PLANS

LOW ACTIVITY LEVEL, ADMINISTRATIVE BASE BUILDING, PLANS AND SCHEDULES

LOW ACTIVITY LEVEL, EQUIPMENT ROOM ADDITION, PLAN AND SCHEDULES

DRAWING LIST, SYMBOL LEGEND AND ABBREVIATIONS

FLOOR PLANS, ELECTRICAL

CAB & CAB ROOF PLANS, ELECTRICAL

DWH-D-ATCT-E015 DETAILS, ELECTRICAL

FIRST FLOOR PLAN, ELECTRICAL

COME BACK THROUGH THE FLOOR.

1. REMOVE SHOWER ON 4TH FLOOR OF TOWER. MAKE SURE DRAIN IS CAPPED, SO NO GASSES

MECHANICAL NOTES:

07/27/2019

ADWH-D-ATCT-G009

CC

SP

INDEX OF DRAWINGS, SYMBOLS/MATERIALS LEGENDS

AND GENERAL NOTES

-a tc t-g

SAMUEL PEREZ

A 08/24/2023 DESCOPED REVISIONS AS-BUILT 1705988 09/15/2023 JV

dwh-d-atct-g009

GLASS

WIRE

3'-0"

4"6"

3'-0"

NO. NAME

ASSISTANT

MANAGEMENT

WOMEN BATHROOM

MEN BATHROOM

BREAKROOM

CONF/TRAINING

QATS

MANAGER

AIR TRAFFIC

HALL

BA

*WATER PROOF

*WATER PROOF

REMARKSCEILINGWALLSBASEFLOORROOM NAME

NO.

HEIGHTMAT'L

ATC 8'-0"GWBGWBGWBGWBRBCPT

8 HALL

CHIEF

EPDS

UNASSIGNED

MEN

WOMEN

SECRETARY

FRAMEDOOR

SET

HDM

DOOR SIZENO.

DOOR

LABEL

DET

SIGN

REMARKS

9/A-4

B 1-1/23'-0"x7'-0"1

7 3'-0"x7'-0"

3'-0"x7'-0"

TYPE MAT'L FIN. MAT'L DET NO. SHT NO.FIN.

A-47P-2HMS-1WDA3

12 B

B WD

WD

WD S-1

S-1

S-1 HM

HM

HM P-2

P-2

P-2 8

8 A-4

A-4

CPT-1 RB-1 WC-1 P-1 P-1 P-1

GWB*CTCTCTCTCTCT

CT-1

CT

VCT

VCT-1

CPT

CPT-1

CPT-1 RB-1

RB

RB-1

CT

CT-1 CT-1 CT-1 CT-1 CT-1 P-1

8'-0"

8'-0"ATC

P-1

GWB*CTCTCTCT

CT-1 CT-1 CT-1 CT-1

GWBGWBGWBGWB

GWB

WC-1

P-1 P-1 P-1

WC-1

1 2 3 4

DOOR TYPES

ROOM ORIENTATION

REFLECTED CEILING PLAN

ROOM SCHEDULE

ROOM FINISH AND DECORATING SCHEDULE

DOOR SCHEDULE

CONSTRUCTION NOTES:

BUILDING STATISTICS

ARCHITECTURAL GENERAL NOTES

ITEM

ROOM: 4

FLOORING. REFER TO DRAWING D-6208A A-5 (FLOOR PLAN).

REMOVE WOOD FLOORING AND INSTALL NEW CERAMIC

REFER TO DRAWING D-6206A A-5 (REFLECTED CEILING PLAN).

TOWER TOWER LINK. (CEILING TILE 2'X'4' ARMSTRONG 3155 WHITE).

MOUNTED LIGHT FIXTURES AT THE ENTIRE BASE BUILDING AND

BUILDING AND TOWER LINK. REPLACE NON WORKING 2'X4' CEILING

REPLACE CEILING TILES WHERE DAMAGE OR MISSING IN BASE

WITH NEW.

WINDOW GASKETS. REPLACE 1 GLASS IN AT MANAGER OFFICE

RESEAL ALL BASE BUILDING WINDOWS AND REPLACE ALL OUTSIDE

PROCESS AND CONSTRUCTION PHASE.

AND MOVE ALL THE FURNITURE DURING THE PAINTING

THE CONTRACTOR SHALL PROVIDE TEMPORARY STORAGE4

SIZE COLOR LOCATION PART NO.

1-800-537-9527

ROPPE

TOE BASE 5/8

STANDARD

BASE

VINYL WALL CHAMELEON

VINYL WALL BASE

BASE BLDG 624

FINISH SCHEDULE

WALL PAINT BEHR MARQUEE HARVEST BROWN

BASE BLDG/ 710D-4

VINYL TILE TRAFFIC MASTER 12"x12"

STICK VINYL TILE)

(THICK PEEL AND

BEIGE SLATE TOWER LINK

1003051951

STORE SKU:

A4272051

MODEL NO.

VINYL TILE TRAFFIC MASTER 12"x12"

1001565526

STORE SKU:

A4260051

MODEL NO.

STICK VINYL TILE)

(THICK PEEL AND

DARK GRAY SLATE

AREA

STAIRWELL

CARPET

@SHAWINC.COM

TOM VARDELL

214-537-8466

1-800-241-4692

COMMERCIAL

PLILADELPHIA

ASHLAR OR BRICK

QUARTER TURN,

MONOLITHIC,

METHOD:

INSTALLATION

CARPET PLANKS

COLOR: SCHOLARLY

STYLE: PRAISE

BASE BLDG/

82705

COLOR: SCHOLARLY

54882

STYLE: PRAISE

PAINT BEHR MARQUEE PURE EARTH

MANAGER OFFICE

AIR TRAFFIC PPU7-5

PAINT BEHR MARQUEE PURE EARTH PPU7-5SUPERVISOR OFFICE

9"x36"

COLOR: BEIGE

STYLE: MATTE BREAKROOM

832-445-0800

NO.888369134693

ROBERT'S FLOORING

OTHER VENDOR:

FLOOR & DECOR

100503457

TILE

PORCELAIN

PORCELAIN TILE

WOOD PLANK

BRADFORD NATURAL

VALLEY RIDGE

MANUFACTURER

BRICK

ASHLAR

MONOLITHIC

1/4 TURN

FLOOR PLAN

9/A-4

D C

EE

A A

CEILING FAN LOCATIONS

F F

BREAKROOM

EQUIPMENT ROOM

SOUND WALL

AF OFFICE

CBI ROOM AT MANAGER

MEN

WOMEN

SECRETARY

/4

5'-1 1/2"8'-8"1'-9"4'-5"5'-6.8"12'-8.7"30'-6.9"

68'-10"

.3

.5

.9

.8

24'-8.9" 18'-0.3" 9'-2.3" 13'-9.4"

13'-4.7"

.7

20'-0.4"18'-0.7"

7'-0.3" 6'-10.7"

3'-2.2"3'-2.2" 3'-2.2"

3'-2.2" 3'-2.2"

3'-2.2"

3'-2.2"4'-0.8" 3'-6.4"

ARE FIRE-TREATED.

OTHER CONSTRUCTION IN EXTERIOR, OR FIRE RATED WALLS,

ALL WOOD USED FOR BLOCKING, NAILERS, FRAMING OR

COMBUSTIBLE MATERIAL.

OPENINGS AROUND PENETRATIONS ARE FILLED WITH NON-

TIGHT TO THE WALL OR ROOF MATERIAL. ALL CRACKS AND

FROM FLOOR SLAB TO ROOF CONSTRUCTION ABOVE AND FITS

FIRE-RATED PARTITIONS EXTENDS FROM WALL TO WALL AND

OF CMU AND TO FACE OF STUDS.

FACE OF INSULATED PANEL, CENTERLINE OF COLUMNS, FACE

ALL DIMENSIONS, UNLESS OTHERWISE NOTED, ARE TO

DESIGN LOADS: SEE STRUCTURAL GENERAL NOTES.

BUILDING GROSS AREA: (64'-7 3/4" x 25'-11 3/4") = 1680 SF

BUILDING HEIGHT: ONE STORY (12'-7")

OCCUPANCY CLASSIFICATION: GROUP B-2 (OFFICE BUILDING)

OF THE LATEST EDITION OF THE UNIFORM BUILDING CODE.

WITH ALL CRITERIA ESTABLISHED THEREBY AND WITH REQ'RS

NON-COMBUSTIBLE) CONSTRUCTION. THE BUILDING COMPLIES

CONSTRUCTION CLASSIFICATION IS TYPE II-N (UNPROTECTED

THE BUILDING. RESEAL AROUND ALL EXTERIOR DOORS AND OPENINGS.

EXTERIOR DOORS ATO PREVENT WIND-DRIVEN RAIN FROM ENTERING

REPLACE FULL EXTERIOR SEAL OF DOOR AND THRESHOLD TO ALL 5

lo tt e

-6 a -a -1

04/30/1985

LARRY LANGWELL

PEH

TOMBALL

RBC

LAM

LOW ACTIVTY LEVEL

ADMINISTRATIVE BASE BUILDING

PLANS AND SCHEDULES

a -a -1

TECHNICAL OPERATIONS

CENTRAL SERVICE AREA FORT WORTH, TX

THIS DRAWING PRODUCED ON THE ASW RO REGION MICROSTATION SYSTEM

W. DONALD SIWNNEY

B 11/21/2005 EQUIP RM ADDITION AS-BUILT PER F.ODANGA 109738 08/20/2005 MAM

C 06/10/2019 AS-BUILT (M. MOLINAR; JON 61034). 1705988 08/20/2005 MAM

D 08/24/2023 CONSTRUCTION (S. PEREZ). 1705988 06/10/2019 SP

E 08/24/2023 DESCOPED REVISIONS 1705988 09/15/2023 JV

d-6208a-a-1

EL 0'-0"

FLOOR LINE

BLOCK

SPLASH

DOWNSPOUT

STUCCO

GUTTER

AWNING

(1) - 6'-0"x4'-6"

(1) - 5'-10"x4'-6"

ADDITION ORIGINAL

CMU

FURRING

1x3 WOOD

1/2" GWB

6"

8'-0"6'-0"

38"

0 1

A 10

8 1

SEALANT AS REQD

WITH ACOUSTICAL

SOUND WALL

CABINETS

FOR KITCHEN

SEE DWG A-6

27'-0"

7'-9 1/2"

2'-0" 3'-10"

18'-2"

3'-4"

16'-3 1/2" 3'-4 1/2" 1'-6"

19'-8 1/4"

NAME

MENS

BREAK ROOM

HALL

EQUIPMENT9

8A

DOOR NO. DOOR SIZE

SET

HDM

TYPE MAT'L

DOOR

FIN. MAT'L FIN.

FRAME

DET NO. SHT NO.

LABEL

DET

SIGN

EQUIP. ROOM9/A-420 MINA-4

A-47A, 7B

7A,7B

8A, 8BMATCH DOOR NO.4

BRONZE/ANODIZED

BRONZE/ANODIZEDAL.

AL.

STEELMATCH DOOR NO.4

CLEAR/ANODIZED

BRONZE/ANODIZEDAL. GLAZED

AL. GLAZED

WDA

B3'-6"x7'-0"

3'-0"x7'-0"8

9 EQUIPMENT ROOM

BREAK ROOM

ROOM NAME FLOOR BASE

21 3 4

WALLS CEILING

MAT'L HEIGHT

P-4

STRUCTURE

ROOF DECKVARIES

8'-0"ATC

ATC-2

EXP

P-4P-4

P-3

GWBGWB

P-4P-4

GWBGWB

P-4RB-3

RB-2

RBSVT

SVT-1

VCT

VCT-3

PARTITION TYPE-C DOOR TYPE

REFERENCE

ROOM ORIENTATION

DOOR SCHEDULE

ROOM FINISH AND DECORATING SCHEDULE

ROOM SCHEDULE

ELL AND ENDING AT 12" FROM BUILDING AND AFF.

1-1/2" SCH 40 PVC CONDUIT WITH A SWEEP

CAPPED UNDERGROUND BEYOND THE SIDEWALK.

(4) - 4" PVC, 1-1/2" COATED RGSC SWEEP ELBOWS

FIRE EXTINGUISHER.

FIRE EXTINGUISHER.

THE EXPANDED PORTION OF THE BREAK ROOM.

PLYWOOD OVER GLASS FIBER INSULATION ATOP

SEE DRAWING SW-D-10539-C1.

TWO 1-1/2" PVC COATED RGC TO THE TOWER.

4"x4" WIREWAY WITH HINGED TOP COVER.

2"x12" CABLE TRAY

2"x12" CABLE LADDER

(4) - 4" PVC COATED RGC 24"1

CONSTRUCTION NOTE:

NOTES:

ELEVATION

NOT TO SCALEA-5

FLOOR PLAN

(REFLECTED CEILING PLANS).

ARMSTRONG 3155 WHITE). REFER TO DRAWING D-6208A A-5

BASE BUILDING AND TOWER LINK. (CEILING TILE 2'x4'

2'x4' CEILING MOUNTED LIGHT FIXTURES AT THE ENTIRE

BASE BUILDING AND TOWER LINK. REPLACE NON WORKING

REPLACE CEILING TILES WHERE DAMAGED OR MISSING IN

lo tt e a -a -5

04/15/2004

MARK G. STACK

PLATFORM MANAGER, ANI-640

MAM

LOW ACTIVITY LEVEL

EQUIPMENT ROOM ADDITION

PLAN AND SCHEDULES

a -a -5

MARCO A. MOLINAR

PROJECT ENGINEER, ANI-640

109738

A 11/21/2005 EQUIP RM ADDITION AS-BUILTS PER F.ODANGA 109738

B 02/06/2007 AS-BUILT (M. MOLINAR; JON 61034). 109738 08/20/2005 MAM

C 06/10/2019 CONSTRUCTION (S. PEREZ). 1705988 06/10/2019 SP

D 08/24/2023 DESCOPED REVISIONS 1705988 09/15/2023 JV

d-6208a-a-5

UP

DAMPER

MOTOR OPERATED

24"x24"LOUVER WITH

ENTRANCE

40' TOWER

WALLS IN

COMPLETE

PROVIDE

IG

STAIRWELL NO.1

IG

BATTERY RACKS

CHARGERS

BATTERY

2" HIGH CURB

MAIN PANEL

MDP

PANEL A

SINK

1 1/2" C POWER

OPERATED DAMPER

WITH MOTOR

24"x24"LOUVER

ROOF DRAIN

(1) 2 1/4" COPPER

PVC DRAIN

(3) 1" COPPER

BLOCK

SPLASH

CONC

PRECAST

FAN

EXHAUST

CLCLCL

2'-8"

6'-6" 5'-3"

7'-1"3'-4"7'-1"

5'-5"

17'-6"

EQUIPMENT

ESU

NATCA ROOM

2ND FLOOR

6/A7 (TYPICAL)

BRACE - SEE DET

DIAGONAL WALL

INTERFERENCE WITH

LOCATED TO AVOID

SEE DET 6/A7

AIR CONDITIONER

CHASE

10E

DOWN

X

METAL SHELF

MIRROR WITH

18"x24"

HOLDER

TOWEL

WC

PAPER HOLDER

6'-5"

FINISHED FLOOR

AT 11'-4" ABOVE

CABLE TRAY

AS REQD (TYP)

LEVELING SUPPORTS

DOOR BELOW STARS

2'-0"x2'-6" ACCESS

PANEL

DC

PANEL

AC

BOX

DEMARCATION

TELCO

CHASE

6E

RAILING

STAIRWELL NO.2

ABOVE

CAB WALL

OUTLINE OF

FAN

EXHAUST

OUTLINE OF CATWALK ABOVE

HEIGHT OF FITTING

DETERMINED BY

FITTING; LOCATION

FOR AIR GAP

ACCESS PANELCHASE

RCU

FIDO

MPX10E

AS REQUIRED (TYP)

LEVELING SUPPORTS

RAILING8

A B

BASE BUILDING

LINK

STORAGE

CLOSET

STAIR NO.1

FACPDC

TOWER LINK

JUNCTION LEVEL

C-3 LEVEL: JUNCTION ROOM.

C-2 LEVEL: ELECTRONIC ROOMS & FILE ROOM.

C-2A LEVEL: NATCA OFFICE & ATC SUPPLY ROOM.

GROUND LEVEL: CABLE TRAY AREA (NEXT TO ESU ROOM)

TO ELECTRICAL DRAWINGS FOR DETAILS.

AND REPLACE ALL CEILING TILES AND REPLACE NON WORKING LIGHT FIXTURES. REFER

AND LIGHT FIXTURES IN CAB AND JUNCTION ROOM. FOR REST OF TOWER SHAFT REMOVE

REMOVE AND REPLACE EXISTING CEILING GRID, CEILING TILES, 2'x4' CEILING MOUNTED

UTILITY

TELCO ROOM

SCALE: 3/8" = 1'-0"A1

C-3 LEVEL

5C-2 LEVEL

C-2A LEVEL

A1A5

A5

FILE

ELECTRONIC

3RD FLOOR

SHOWER

JUNCTION

TOILET

2'-9"

SUPPLY

SCALE: 3/8" = 1'-0"

4' 6'2'02'

BLACK 24" x 24" x 1").

BPSM2824BK COLORATION SQUARE TEGULAR 2824

ONLY NATCA OFFICE. (ARMSTRONG CALLA ITEM

WITH WHITE GRID).

ARMSTRONG 3155 WHITE WITH STANDARD WHITE GRID), (ARMSTRONG CALLA ITEM

EXISTING CEILING (SMOKE DETECTORS, FIRE ALARM HORN STROBE). (CEILING TILE 2'x4'

CONTRACTOR SHALL REMOVE AND RE-INSTALL ALL EQUIPMENT ATTACHED TO THE

REMOVE EXISTING DRYWALL PARTITION.

CAP DRAIN AND SUPPLY WATER.

REMOVE EXISTING FIBERGLASS SHOWER.

REMOVE CEILING TILE & SUSPENSION SYSTEM.

C-3 LEVEL SHOWER ROOM:

:0 lo tt e

-9

-a

12/02/1974

ROGER F. BECK

CHIEF OF BRANCH, ASW-440

TOWER FLOOR PLANS

ROBERT J. REHAGEN

CHIEF OF SECTION, ASW-441

D 08/20/2012 ROOF REPLACEMENT AND TWR SHAFT MOD PROJ 908408

E 01/21/2014 AS-BUILT (C. LAY-SOK; JON 20449). 908408 01/21/2014 SP

F 06/10/2019 CONSTRUCTION (S. PEREZ). 1705988 06/10/2019 JV

G 08/24/2023 DESCOPED REVISIONS 1705988 09/15/2023 JV

sw-d-9229-a1

Q

CONTROL CAB

WITH RE. REFER TO ELECTRICAL DRAWING FOR DETAILS.

PROVIDE AND INSTALL NEW CEILING FANS. COORDINATE LOCATION

CEILING SHALL BE COVERED WITH THIS INSULATION.

CEILING TILES. INSULATION SHALL BE 24"x48". THE ENTIRE CAB

PROVIDE AND INSTALL R-19 BATT INSULATION ON TOP OF THE

SUBMIT PRODUCT DATA FOR APPROVAL PRIOR TO CONSTRUCTION.

B. ARMSTRONG PRELUDE XL 15/16" EXPOSED TEE IN TECH BLACK.

TEGULAR 2820 BLACK 24"x24"x1".

A. ARMSTRONG CALLA ITEM 2820BK COLORATIONS SQUARE

FURNISH AND INSTALL NEW CEILING TILES AND SUSPENSION SYSTEM.

DEMOLISH ALL EXISTING CEILING TILE AND SUSPENSION SYSTEM.

W8x10

EXISTING

3/8" PLATE

WELD (4 SIDES)

1/4" FILLET

4"x4"x1/8" TUBE

WELD (4 SIDES)

1/4" FILLET

PLATE

7"x7"x3/8"

DIAMETER

0.5"

R=0.25"

.2

4"

5'-10 3/8"

/8

4'-7 1/16"

HANDRAIL

5"

SPECIFIED

ROOFING AS

PLATFORM

DUCKBOARD

TURNED 90 DEGREES

PLATFORM AND

A/C UNIT

HATCH

ROOF

ELECTRICAL DRAWINGS

3 PLACES, TYP, SEE

OBSTRUCTION LIGHT

SEE DET 3/A7

SCUPPER

OVERFLOW

SEE ELEC DWGS

TYP 3 PLACES

AIR TERMINAL,

PROTECTION

LIGHTNING

TYP, SEE

DUCKBOARD

6'-9" 6'-9"

3'-9"

4'-6"

11'-10 1/16"

9"

SEE DWG A7 FOR WINDOW DETAILS

GLASS

1" INSULATED

AND SILL

WELDED TO HEAD

MULLION S4x7.7

FROM CONTRACT

CARPET DELETED

(BY OTHERS)

CONSOLE EQUIPMENT

TUBE 6x3

5'-11" 11'-10"

23'-8"

5'-11"

SHADE POCKET

SUPPLY GRILL

OVER CEILING TILES

R-19 BATT INSULATION

GRILL 24"x48"

RETURN AIR

OPENING FOR HOIST HOOK

PROVIDE GROMMETTED

INSTALL CEILING FAN

B-21

B-1

B-19 B-19

SUPPORT (TYP)

ARTICULATING ARM

6 1

QQ

AP

PR

OX

7'-

6"

(T

YP

2'-0" 2'-0"

24"

5"

1/ 2"

4" 2'-4 1/2"

DETAILS

SEE STR DWGS FOR

CATWALK AND RAILING

DRAWINGS

SPECIFICATIONS AND CONSOLE LAYOUT

A PARTICULAR SITE - SEE CONTRACT

FOR CONSOLE LAYOUT VARIATIONS AT

OUTLINE OF TOWER BELOW

(BY OTHERS)

CONSOLE EQUIPMENT

SEE 5/A6

HATCH,

FLOOR

MET WALL

3'-0" HIGH

UNIT

CONVENIENCE

LADDER

HATCH

LADDER

5 1/8" 2'-6"

/8

9'-4"

18'-8"

SCALE: 3/8" = 1'-0"

4' 6'2'02'

CONTROL CAB WINDOW PLAN

SCALE: 3/8" = 1'-0"A2

2 ARTICULATING ARM MOUNTING TUBE

NOT TO SCALEA2

ROOF PLAN

INSTALLED GLASS OPENING DIMENSIONS

NOT TO SCALEA2

SYSTEM.

SHALL BE DONE AFTER THE INSTALLATION OF CEILING GRID

SATISFACTORY OPERATION AND USE OF THE LADDER. THIS WORK

COMPONENTS, ACCESSORIES AND CONTROL REQUIRED FOR

TELESCOPING LADDER WITH SPECIAL DEEP STEEL FRAME. PROVIDE THE

REMOVE EXISTING TELESCOPING LADDER AND REPLACE WITH A NEW

FLOOR PLAN-CONTROL CAB

TYP COL 2 6x3 1/2

M2

WITH NEW.

REPLACE ALL FLOORING IN TOWER CAB AND JUNCTION FLOOR LEVEL6.

M2 lo tt e

12/02/1974

RGOGER F. BECK

MANAGER OF BRANCH, ASW-440

CAB FLOOR, WINDOW, CEILING

AND ROOF PLANS

ROBERT J. REHAGEN

CHIEF OF SECTION, ASW-441

109738

B 11/21/2004 AS BUILT PER FRED ODANGA. 109738 08/20/2005 MAM

C 02/06/2007 AS-BUILT (M. MOLINAR; JON 61034). 1705988 08/20/2005 MAM

D 06/10/2019 CONSTRUCTION (S. PEREZ). 1705988 06/10/2019 SP

E 08/24/2023 DESCOPED REVISIONS 1705988 09/15/2023 JV

sw-d-9229-a2

File details come from the government source that posted it. Updated .