Attachment J - Signage Specifications.pdf

PDF 314 KB Posted

Attached to
Pershing High School Bid Pack 2C- Signage and Final Cleaning
Solicitation number
RFP DET 270000000026 1
Issued by
Wayne County, Michigan

About this file

This is a Signage Specifications document for Pershing High School in Michigan, outlining detailed requirements for signage installation as part of Bid Pack 2C. The specification document establishes comprehensive standards for all signage work to be performed at the school, including requirements for materials, installation methods, finishes, and quality standards. The document details specific signage categories and types required throughout the facility, with particular attention to durability, safety compliance, and aesthetic consistency with the school's design standards. Installation must comply with all applicable building codes and accessibility standards, with specifications covering mounting hardware, weatherproofing, and finishing requirements to ensure professional appearance and longevity of all signage installations.

The specifications establish quality benchmarks and material standards that bidders must meet or exceed in their proposals. All signage work must be performed by qualified installers with demonstrated experience in educational facility signage projects. The document references standard industry practices and codes for signage installation, requiring bidders to provide detailed methodology for implementation and timeline for completion. Specifications include requirements for coordination with other trades, protection of existing facilities during installation, and final inspection and acceptance procedures. Bidders must demonstrate compliance with all specifications in their bid submissions, with pricing to reflect full adherence to the detailed requirements outlined in this attachment.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pershing High School BP02 Addendum 01

QE Project No. 42245900 October 25, 2024

DIMENSIONAL LETTER SIGNAGE 101419 - 1

SECTION 101419

DIMENSIONAL LETTER SIGNAGE

PART 1 - GENERAL

1.01 SUMMARY

A. Section Includes:

1. Dimensional characters.

a. Cast dimensional characters.

b. Illumination Systems.

1.02 ACTION SUBMITTAL

A. Product Data: For each type of product.

B. Shop Drawings: For signs.

1. Include fabrication and installation details and attachments to other work.

2. Show sign mounting heights, locations of supplementary supports to be provided by other installers, and accessories.

3. Show message list, typestyles, graphic elements, and layout for each sign at least half size.

C. Samples for Initial Selection: For each type of sign assembly, exposed component, and exposed finish.

1. Include representative Samples of available typestyles and graphic symbols.

D. Samples for Verification: For each type of sign assembly showing all components and with the required finish(es), in manufacturer's standard size unless otherwise indicated and as follows:

1. Dimensional Characters: Full-size Sample of dimensional character.

2. Full-size Samples, if approved, will be returned to Contractor for use in the Project.

E. Product Schedule: For dimensional letter signs. Use same designations indicated on Drawings or specified.

F. Delegated Design Data: Submit comprehensive structural analysis of design for mounting and securing the signage letters. Include provisions for wind, snow, and other loads impacting the signage. Analysis data to be stamped and signed calculations by professional engineer.

1.03 INFORMATIONAL SUBMITTAL

A. Qualification Data: For Installer and manufacturer.

B. Sample Warranty: For special warranty.

1.04 CLOSEOUT SUBMITTALS

A. Maintenance Data: For signs to include in maintenance manuals.

1.05 QUALITY ASSURANCE

A. Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer.

1.06 WARRANTY

A. Special Warranty: Manufacturer agrees to repair or replace components of signs that fail in materials or workmanship within specified warranty period.

1. Failures include, but are not limited to, the following:

a. Deterioration of finishes beyond normal weathering.

b. Separation or delamination of sheet materials and components.

2. Warranty Period: Five years from date of Substantial Completion.

PART 2 - PRODUCTS

2.01 PERFORMANCE REQUIREMENTS

A. Thermal Movements: For exterior dimensional letter signage, allow for thermal movements from ambient and surface temperature changes.

DIMENSIONAL LETTER SIGNAGE 101419 - 2

1. Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.

2.02 DIMENSIONAL CHARACTERS

A. Cast Characters: Characters with uniform faces, sharp corners, and precisely formed lines and profiles, and as follows:

1. Manufacturers: Subject to compliance with requirements, provide products by one of the following or as approved by the Architect and Owner:

a. A.R.K. Ramos.

b. Gemini Incorporated.

c. Matthews International Corporation; Bronze Division.

d. Metallic Arts.

e. Southwell Company (The).

2. Character Material: Cast aluminum.

3. Character Height: As indicated on Drawings.

4. Thickness: 1-inch, unless otherwise indicated on Drawings.

5. Finishes:

a. Integral Aluminum Finish: Clear anodized.

6. Mounting: Concealed studs.

7. Illumination System: Halo-lit reverse channel letters .

a. Provide products that are listed and labeled as complying with UL 879, where applicable.

b. Power: 120 V, 60 Hz, 1 phase, 15 A .

2.03 DIMENSIONAL CHARACTER MATERIALS

A. Aluminum Castings: ASTM B26/B26M, alloy and temper recommended by sign manufacturer for casting process used and for type of use and finish indicated.

2.04 ACCESSORIES

A. Fasteners and Anchors: Manufacturer's standard as required for secure anchorage of signs, noncorrosive and compatible with each material joined, and complying with the following:

1. Use concealed fasteners and anchors unless indicated to be exposed.

2. For exterior exposure, furnish stainless steel devices unless otherwise indicated.

3. Sign Mounting Fasteners:

a. Concealed Studs: Concealed (blind), threaded studs welded or brazed to back of sign material, screwed into back of sign assembly, or screwed into tapped lugs cast integrally into back of cast sign material, unless otherwise indicated.

4. Electrical Components and Devices: Listed and labeled as defined in NFPA 70 by a qualified testing agency.

2.05 FABRICATION

A. General: Provide manufacturer's standard sign assemblies according to requirements indicated.

1. Preassemble signs and assemblies in the shop to greatest extent possible. Disassemble signs and assemblies only as necessary for shipping and handling limitations. Clearly mark units for reassembly and installation; apply markings in locations concealed from view after final assembly.

2. Mill joints to a tight, hairline fit. Form assemblies and joints exposed to weather to resist water penetration and retention.

3. Comply with AWS for recommended practices in welding and brazing. Provide welds and brazes behind finished surfaces without distorting or discoloring exposed side. Clean exposed welded and brazed connections of flux, and dress exposed and contact surfaces.

4. Conceal connections if possible; otherwise, locate connections where they are inconspicuous.

5. Provide rabbets, lugs, and tabs necessary to assemble components and to attach to existing work. Drill and tap for required fasteners. Use concealed fasteners where possible; use exposed fasteners that match sign finish.

DIMENSIONAL LETTER SIGNAGE 101419 - 3

6. Castings: Fabricate castings free of warp, cracks, blowholes, pits, scale, sand holes, and other defects that impair appearance or strength. Grind, wire brush, sandblast, and buff castings to remove seams, gate marks, casting flash, and other casting marks before finishing.

2.06 GENERAL FINISH REQUIREMENTS

A. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.

B. Appearance of Finished Work: Noticeable variations in same piece are not acceptable.

Variations in appearance of adjoining components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast.

C. Organic, Anodic, and Chemically Produced Finishes: Apply to formed metal after fabrication but before applying contrasting polished finishes on raised features unless otherwise indicated.

2.07 ALUMINUM FINISHES

A. Clear Anodic Finish: AAMA 611, Class I, 0.018 mm or thicker.

PART 3 - EXECUTION

3.01 EXAMINATION

A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance.

B. Verify that sign-support surfaces are within tolerances to accommodate signs without gaps or irregularities between backs of signs and support surfaces unless otherwise indicated.

C. Proceed with installation only after unsatisfactory conditions have been corrected.

3.02 INSTALLATION OF DIMENSIONAL CHARACTERS

A. General: Install signs using mounting methods indicated and according to manufacturer's written instructions.

1. Install signs level, plumb, true to line, and at locations and heights indicated, with sign surfaces free of distortion and other defects in appearance.

2. Before installation, verify that sign surfaces are clean and free of materials or debris that would impair installation.

3. Corrosion Protection: Coat concealed surfaces of exterior aluminum in contact with grout, concrete, masonry, wood, or dissimilar metals, with a heavy coat of bituminous paint.

B. Mounting Methods:

1. Concealed Studs: Using a template, drill holes in substrate aligning with studs on back of sign. Remove loose debris from hole and substrate surface.

a. Masonry Substrates: Fill holes with adhesive. Leave recess space in hole for displaced adhesive. Place sign in position and push until flush to surface, embedding studs in holes. Temporarily support sign in position until adhesive fully sets.

b. Thin or Hollow Surfaces: Place sign in position and flush to surface, install washers and nuts on studs projecting through opposite side of surface, and tighten.

3.03 ADJUSTING AND CLEANING

A. Remove and replace damaged or deformed characters and signs that do not comply with specified requirements. Replace characters with damaged or deteriorated finishes or components that cannot be successfully repaired by finish touchup or similar minor repair procedures.

B. Remove temporary protective coverings and strippable films as signs are installed.

C. On completion of installation, clean exposed surfaces of signs according to manufacturer's written instructions and touch up minor nicks and abrasions in finish. Maintain signs in a clean condition during construction and protect from damage until acceptance by Owner.

END OF SECTION 101419

Pershing High School Bid Package 02

QE Project No. 42245900 September 13, 2024

PANEL SIGNAGE 101423 - 1

SECTION 101423

PANEL SIGNAGE

PART 1 GENERAL

1.01 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

1.02 SUMMARY

A. This Section includes the following:

1. Panel signs.

1.03 SUBMITTALS

A. Product Data: For each type of product indicated.

B. Shop Drawings: Show fabrication and installation details for signs.

1. Show sign mounting heights, locations of supplementary supports to be provided by others, and accessories.

2. Provide message list, typestyles, graphic elements, and layout for each sign.

C. Samples for Initial Selection: For each of the following products and for the full range of color, texture, and sign material indicated, of sizes indicated:

1. Acrylic Sheet: 8 by 10 inches for each color required.

D. Sign Schedule: Use designations as directed by Architect.

E. Maintenance Data: For signs to include in maintenance manuals.

1.04 QUALITY ASSURANCE

A. Fabricator Qualifications: Shop that employs skilled workers who custom-fabricate products similar to those required for this Project and whose products have a record of successful in-service performance.

B. Source Limitations for Signs: Obtain each sign type indicated from one source from a single manufacturer.

1.05 PROJECT CONDITIONS

A. Field Measurements: Verify recess openings by field measurements before fabrication and indicate measurements on Shop Drawings.

1.06 COORDINATION

A. Coordinate placement of anchorage devices with templates for installing signs.

1.07 WARRANTY

A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of signs that fail in materials or workmanship within specified warranty period.

1. Warranty Period: One year from date of Substantial Completion.

PART 2 PRODUCTS

2.01 MATERIALS

A. Acrylic Sheet: ASTM D 4802, Category A-1 (cell-cast sheet), Type UVA (UV absorbing).

2.02 PANEL SIGNS

A. Manufacturers: Subject to compliance with requirements, provide products by one of the following or as approved by the Architect and Owner:

1. ACE Sign Systems, Inc.

2. American Graphics, Inc.

3. Andco Industries Corp.

4. ASI-Modulex, Inc.

5. Best Sign Systems Inc.

PANEL SIGNAGE 101423 - 2

6. FFI Group, Inc.

7. Gemini Incorporated.

8. Innerface Sign Systems, Inc.

9. Sign Masters.

10. Sign Print, Inc.

11. Sign Systems, Inc.

12. Signature Signs, Incorporated.

B. Interior Panel Signs: Provide smooth sign panel surfaces constructed to remain flat under installed conditions within a tolerance of plus or minus 1/16 inch (1.5 mm) measured diagonally from corner to corner, complying with the following requirements:

1. Acrylic Sheet: 0.080 inch (2.03 mm) thick.

2. Edge Condition: Square cut.

3. Corner Condition: Square.

4. Mounting: Unframed.

a. Wall mounted with two-face tape.

b. Manufacturer's standard anchors for substrates encountered.

5. Color: As selected by Architect from manufacturer’s full range.

C. Colored Coatings for Acrylic Sheet: For copy and background colors, provide colored coatings, including inks, dyes, and paints, that are recommended by acrylic manufacturers for optimum adherence to acrylic surface and are UV and water resistant for three years for application intended.

1. Color: As selected by Architect from manufacturer’s full range.

D. Panel Sign Schedule:

1. Sign Type:

a. Sign Size: As directed by Architect.

b. Message Panel Material: Cast acrylic sheet.

c. Character Size: Minimum 3/4-inch-high characters.

d. Character Finish/Color: As selected by Architect from manufacturer’s full range.

e. Text/Message: To be verified with Architect prior to fabrication and submittal of shop drawings.

2.03 FINISHES, GENERAL

A. Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes.

B. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.

C. Appearance of Finished Work: Variations in appearance of abutting or adjacent pieces are acceptable if they are within one-half of the range of approved Samples. Noticeable variations in the same piece are not acceptable. Variations in appearance of other components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast.

2.04 ACRYLIC SHEET FINISHES

A. Colored Coatings for Acrylic Sheet: For copy and background colors, provide colored coatings, including inks, dyes, and paints, that are recommended by acrylic manufacturers for optimum adherence to acrylic surface and that are UV and water resistant for three years for application intended.

PART 3 EXECUTION

3.01 EXAMINATION

A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of work.

B. Verify that items, including anchor inserts, are sized and located to accommodate signs.

C. Proceed with installation only after unsatisfactory conditions have been corrected.

PANEL SIGNAGE 101423 - 3

3.02 INSTALLATION

A. Locate signs and accessories where indicated, using mounting methods of types described and complying with manufacturer's written instructions.

1. Install signs level, plumb, and at heights indicated, with sign surfaces free of distortion and other defects in appearance.

2. Interior Wall Signs: Install signs at the following heights:

a. Maximum Occupancy Signs: 8’-0” to bottom.

b. No Storage signs: As high as possible.

B. Wall-Mounted Signs: Comply with sign manufacturer's written instructions except where more stringent requirements apply.

1. Two-Face Tape: Mount signs to smooth, nonporous surfaces. Do not use this method for vinyl-covered or rough surfaces.

2. Attach signs to irregular, porous, or vinyl-covered surfaces.

3.03 CLEANING AND PROTECTION

A. After installation, clean soiled sign surfaces according to manufacturer's written instructions.

Protect signs from damage until acceptance by Owner.

END OF SECTION 101423