Attachment J Security Unit Price List FSL II.xlsx
XLSX spreadsheet 20 KB Posted
- Attached to
- X1DB--Providence PT/OT New Location
- Solicitation number
- 36C24124R0109
About this file
This document is the Security Unit Price List for Request for Lease Proposal 36C24124R0109 related to a Department of Veterans Affairs Community Based Outpatient Clinic (CBOC) in Providence, Rhode Island. The price list covers various security requirements for the facility, including access control, screening, signage, landscaping, security systems, and other criteria. The unit prices are to be filled out and submitted post-award, with the total costs included as Building Specific Amortized Capital (BSAC) on the GSA Form 1364. The security requirements and associated pricing are non-negotiable following lease award. Specific requirements are outlined for facility entrances, interior spaces, sites and exterior, security systems, and building structure. The instructions note that the price list must be submitted with all offers in response to the RLP.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Security Unit Costs INSTRUCTIONS TO THE LEASING SPECIALISTS: THIS SPREADSHEET REFLECTS THE BASELINE SET OF SECURITY PARAGRAPHS. EACH PARAGRAPH IN THE SECURITY SECTION WILL HAVE A CORRESPONDING LINE. IF THE SECURITY SECTION IS ADJUSTED BY ADDING OR DELETING PARAGRAPHS THE SPREADSHEET MUST BE CHANGED ACCORDINGLY.
| SECURITY UNIT PRICE LIST (FSL II) | ||||
| REQUEST FOR LEASE PROPOSAL 36C24124R0109 | ||||
| [INSERT DATE] | ||||
| VA CBOC | ||||
| PROVIDENCE, R.I. | ||||
| To be filled out post-award | ||||
| The following security countermeasures are required by the Request for Proposals package. Using this form, the offeror shall quote unit prices on all security countermeasures identified in the RLP package, and enter the total costs on the GSA Form 1364 as Building Specific Amortized Capital (BSAC). Upon lease award, BSAC pricing shall be fixed and not subject to further negotiation. Refer to "Security Requirements" attachment to the lease for additional details. This form must be submitted with all offers. | ||||
| Lease Security Standards Section | Unit Price | Quantity | Total |
| I. | FACILITY ENTRANCES, LOBBY, COMMON AREAS, NON-PUBLIC, AND UTILITY AREAS | |
| A. | FACILITY ENTRANCES AND LOBBY | |
| 1. | EMPLOYEE ACCESS CONTROL AT ENTRANCES (SHELL) | Priced in Shell |
| B. | SCREENING REQUIREMENTS | |
| 1. | ACCOMODATION OF RETAIL/MIXED USE SPACE (SHELL) | Priced in Shell |
| C. | COMMON AREAS, NON-PUBLIC, AND UTILITY AREAS | ||
| 1. | PUBLIC RESTROOM ACCESS (SHELL) | Priced in Shell | |
| 2. | SECURING CRITICAL AREAS (SHELL) | Priced in Shell | |
| 3. | VISITOR ACCESS CONTROL (SHELL) | Priced in Shell | |
| 4. | PUBLIC SPACE RESTRICTIONS WITH PRIMARY VERTICAL LOAD MEMBERS | $ - 0 | |
| 4a. | RESTRICT CONTACT FROM PUBLIC AREAS WITH PRIMARY VERTICAL LOAD MEMBERS | $ - 0 | |
| 4b. | RESTRICT CONTACT FROM MAIL AREAS WITH PRIMARY VERTICAL LOAD MEMBERS | $ - 0 |
| II. | INTERIOR (GOVERNMENT SPACE) | |
| A. | IDENTITY VERIFICATION (SHELL) | Priced in Shell |
| B | FORMAL KEY CONTROL PROGRAM (SHELL) | Priced in Shell |
| III. | SITES AND EXTERIOR OF THE BUILDING | |
| A. | SIGNAGE | |
| 1. | POSTING OF SIGNAGE IDENTIFYING THE SPACE AS GOVERNMENTAL (SHELL) | Priced in Shell |
| 2. | POSTING OF REGULATORY SIGNAGE (SHELL) | Priced in Shell |
| B. | LANDSCAPING AND ENTRANCES | |
| 1. | LANDSCAPING REQUIREMENTS (SHELL) | Priced in Shell |
| 2. | HAZMAT STORAGE (SHELL) | Priced in Shell |
| 3. | PLACEMENT OF RECEPTACLES, CONTAINERS, AND MAILBOXES (SHELL) | Priced in Shell |
| C. | PARKING | |
| 1. | PUBLIC ACCESS TO GOVERNMENT PARKING AREAS (SHELL) | Priced in Shell |
| IV. | SECURITY SYSTEMS | |
| A. | SECURITY SYSTEM TESTING & MAINTENANCE CRITERIA | $ - 0 |
| B. | VIDEO SURVEILLANCE SYSTEM (VSS) | ||
| LESSOR PROVIDED DESIGN, INSTALLATION, AND MAINTENANCE | $ - 0 | ||
| GOVERNMENT PROVIDED SCOPE, PRODUCT, INSTALLATION, AND MAINTENANCE | Government Provided |
| C. | INTRUSION DETECTION SYSTEM | ||
| LESSOR PROVIDED DESIGN, INSTALLATION, AND MAINTENANCE | $ - 0 | ||
| GOVERNMENT PROVIDED SCOPE, PRODUCT, INSTALLATION, AND MAINTENANCE | Government Provided |
| D. | DURESS ALARM | ||
| LESSOR PROVIDED DESIGN, INSTALLATION, AND MAINTENANCE | $ - 0 | ||
| GOVERNMENT PROVIDED SCOPE, PRODUCT, INSTALLATION, AND MAINTENANCE | Government Provided |
E. SECURITY SYSTEMS DESIGN $ - 0
| V. | STRUCTURE | |
| A. | WINDOWS | |
| LOCK GROUND FLOOR WINDOWS (BSAC- IDS Monitoring) | $ - 0 |
| B. | BUILDING SYSTEMS | ||
| 1. | EMERGENCY GENERATOR PROTECTION (T.I.) | Priced in Tenant Improvements | |
| 2. | SECURE AIR INTAKE GRILLES | $ - 0 |
| VI. | OPERATIONS AND ADMINISTRATION | |
| A. | FACILITY SECURITY COMMITTEE (FSC) - (SHELL *) | Priced in Shell |
| B. | ACCESS TO BUILDING INFORMATION (SHELL *) | Priced in Shell |
| C. | CONSTRUCTION SECURITY PLAN (SHELL) | Priced in Shell |
| VII. | CYBERSECURITY (SHELL *) | ||
| CYBERSECURITY REQUIREMENTS OUTLINED IN SECTIONS A-C (SHELL *) | Priced in Shell | ||
| TOTAL COSTS | $ - 0 |
Security Unit Price List (Level II)
REV (08 2021)
&P
Security Unit Price List (Level III) REV (xx 2021) Page #
Security Unit Price List (Level II)
REV (08 2021)
&P
Security Unit Price List (Level II)
REV (06 2022)
&P
Sheet1
File details come from the government source that posted it. Updated .