This solicitation requests proposals for the construction of two hoop house greenhouse structures in Hilo, Hawaii. The Agricultural Research Service of the Department of Agriculture seeks to award a fixed-price construction contract for the turnkey installation of the greenhouses, including all necessary materials, equipment, labor and technical support. Proposals are due by April 15, 2023. The period of performance is 120 calendar days following award. The contractor will be responsible for obtaining any required permits and coordinating inspections. Preference will be given to service-disabled veteran-owned small businesses.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
20'-0" AND 24'-0" WIDE WITH LEGS
INSTRUCTION MANUAL
COLD FRAME SERIES 1100
GREEN HOUSE SYSTEM
IMPORTANT!!!!!
NON - CODE COLD FRAMES REPRESENT A NON - CODE- NON
ENGINEERED DESIGN WITH CERTIFICATION UNAVAILABLE. IT IS
NOT RECOMMENDED THAT THIS HOUSE BE UTILIZED IN REGIONAL
AREAS REPRESENTING SNOW OR HIGH WIND FACTORS.
NOTE:
ENDWALL COLUMN SPACING ILLUSTRATED
MAY VARY TO ACCOMMODATE DOOR SIZING.
'-0" CENTER TO CENTER
'-0" CENTER TO CENTER '-0"
AutoCAD SHX Text
GENERAL CONTRACTORS LICENSE NO. 323391-B
AutoCAD SHX Text
FAX (909) 628-3774
AutoCAD SHX Text
SERVING AGRICULTURE SINCE 1946 A DIVISION OF JOHN L. CONLEY, INC.
AutoCAD SHX Text E
AutoCAD SHX Text
GREENHOUSE MANUFACTURING & SALES
AutoCAD SHX Text
4344 MISSION BLVD.
AutoCAD SHX Text
(909) 627-0981
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text U
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text
MONTCLAIR, CA. 91763
AutoCAD SHX Text
(800) 377-8441
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text T
AutoCAD SHX Text H
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text S
AutoCAD SHX Text F
AutoCAD SHX Text L
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text R i
TABLE - CONTENTS
INTRODUCTION -----------------------------------------------------------------------------------------------------------------------
DISCLAIMER ---------------------------------------------------------------------------------------------------------------------------
NOTICE TO CONLEY'S CUSTOMERS
PROTECT YOURSELF FROM ADDED COSTS----------------------------------------------------------------------------------
WARRANTY ---------------------------------------------------------------------------------------------------------------------------
NOTATION - INSTRUCTIONS PROVIDED ----------------------------------------------------------------------------------
GRADE AND PREPARE THE BUILDING SITE --------------------------------------------------------------------------------
LAYOUT AND SQUARE THE FOUNDATION ---------------------------------------------------------------------------------
FIND COLUMN CENTERS ----------------------------------------------------------------------------------------------------------
AUGER COLUMN HOLES ----------------------------------------------------------------------------------------------------------
-FSETTING THE LINES -----------------------------------------------------------------------------------------------------------
SLOPE LINES ---------------------------------------------------------------------------------------------------------------------------
MARK CENTERS ON COLUMN ---------------------------------------------------------------------------------------------------
MARK COLUMNS --------------------------------------------------------------------------------------------------------------------
SET COLUMNS -------------------------------------------------------------------------------------------------------------------------
COLUMN TO ARCH CONNECTOR -----------------------------------------------------------------------------------------------
INSTALLATION - ARCHES ------------------------------------------------------------------------------------------------------
PURLIN INSTALLATION ------------------------------------------------------------------------------------------------------------
INSTALL REMAINING ARCHES AND PURLINS ------------------------------------------------------------------------------
INSTALL "X" BRACING -------------------------------------------------------------------------------------------------------------
GIRT INSTALLATION (WOOD OR METAL) -----------------------------------------------------------------------------------
DOOR END WALL WITH METAL GIRTS ---------------------------------------------------------------------------------------
SOLID END WALL WITH METAL GIRTS ---------------------------------------------------------------------------------------
20'-0" COLD FRAME WITH LEGS ARCH PARTS LIST -----------------------------------------------------------------------
20'-0" COLD FRAME WITH LEGS END WALL PARTS LIST ----------------------------------------------------------------
20'-0" COLD FRAME WITH LEGS END WALL WITH DOOR
PARTS LIST -----------------------------------------------------------------------------------------------------------------------------
24'-0" COLD FRAME WITH LEGS ARCH PARTS LIST ----------------------------------------------------------------------
24'-0" COLD FRAME WITH LEGS END WALL PARTS LIST ---------------------------------------------------------------
24'-0" COLD FRAME WITH LEGS END WALL WITH DOOR
PARTS LIST ----------------------------------------------------------------------------------------------------------------------------
COVERING TRIM INSTALLATION -----------------------------------------------------------------------------------------------
Page 1 - 2
Page 3 - 5
Page 10 - 11
Page 12 - 13
Page 15 - 16
Page 17 - 18 ii
TABLE OF CONTENTS
COVERING TRIM INSTALLATION OPTIONS ---------------------------------------------------------------------------------
GABLE END BAR OPTION ---------------------------------------------------------------------------------------------------------
INSTALLATION OF POLY COVERING WITH TUBE LOCK ---------------------------------------------------------------
INSTALLATION OF POLY COVERING ON ARCHED BUILDINGS ------------------------------------------------------
INSTALLATION OF INFLATOR FAN --------------------------------------------------------------------------------------------
INFLATOR FAN ASSEMBLY ------------------------------------------------------------------------------------------------------
INSTALLATION OF POLY COVERING WITH VINNIPET SPRING -------------------------------------------------------
Page 27 - 28
ALL PRODUCTS ARE SOLD F.O.B. SHIPPING POINT, AND THE ATTACHED MEMORANDUM COPY OF
BILL OF LADING THAT INDICATES THAT MATERIAL SHIPPED HAS NOW, BY LAW, BECOME YOUR
PROPERTY AND IS AN ACKNOWLEDGMENT BY THE TRANSPORTATION COMPANY OF THE RECEIPT OF
THE MATERIALS IN GOOD CONDITION.
SAFE DELIVERY OF THIS SHIPMENT IS NOW THE RESPONSIBILITY OF THE CARRIER WHO ACTS AS YOUR
AGENT. WE WILL BE GLAD TO RENDER ASSISTANCE TO TRACE AND RECOVER LOST GOODS.
EXAMINE THE SHIPMENT CAREFULLY BEFORE SIGNING THE FREIGHT BILL. IF ANY DAMAGE IS NOTED, OR OF THE NUMBER OF PIECES DOES NOT AGREE WITH THE BILL OF LADING, INSIST THAT SHORTAGE OR
DAMAGE BE NOTED ON THE FREIGHT BILL BY THE CARRIERS AGENT. FAILURE TO DO SO MAY
JEOPARDIZE YOUR RECOVERY.
DO NOT REFUSE SHIPMENT AS THIS IS YOUR PROPERTY AND REFUSAL CAUSES UNNECESSARY DELAYS
AND SHORTAGE EXPENSES. ARRANGE WITH CARRIER WITHIN 15 DAYS TO INSPECT AND MAKE
REFERENCE THERE TO ON THE FREIGHT BILL. CONSULT YOUR CARRIER FOR DISPOSITION OF DAMAGED
ARTICLES.
THE FOLLOWING INSTRUCTIONS ARE GIVEN AS SUGGESTED GUIDELINES FOR GENERAL INSTRUCTIONS.
CONLEY'S MANUFACTURING AND SALES OR ANY OF THEIR EMPLOYEES SHALL NOT BE RESPONSIBLE FOR DAMAGES RESULTING FROM PURCHASERS IMPLEMENTATION OF THESE INSTRUCTIONS. PURCHASERS ALONE SHALL BE RESPONSIBLE FOR CONFORMANCE WITH ALL APPLICABLE LAWS, ORDINANCES, AND SAFETY STANDARDS IN CONSTRUCTING THIS GREENHOUSE AND ALL EQUIPMENT INSTALLED THEREIN.
SHOULD YOU HAVE ANY QUESTIONS CONCERNING THESE INSTRUCTION, COMPONENTS ETC..., PLEASE
CONTACT US DIRECTLY. WE WELL BE GLAD TO ANSWER ANY QUESTIONS CONCERNING OUR
MANUFACTURED PRODUCT.
INCLUDED IN THIS PACKAGE ARE INSTRUCTIONS AND DETAILED DRAWINGS PERTAINING TO YOUR CONLEY'S GREENHOUSE SYSTEM. STUDY THE INSTRUCTIONS BEFORE BEGINNING CONSTRUCTION TO
BECOME FAMILIAR WITH OUR PRODUCT AND HOW IT IS ASSEMBLED.
STORE ALL MATERIALS OFF THE GROUND ON WOOD BLOCKS. PROTECT ALL YOUR MATERIALS FROM
THEFT AND/OR DAMAGE. YOU MAY WISH TO DISCUSS BUILDERS RISK INSURANCE WITH YOUR
INSURANCE AGENT.
NOTICE TO CONLEY'S CUSTOMERS
PROTECT YOURSELF FROM ADDED COSTS
DISCLAIMER
INTRODUCTION
CONLEY'S MANUFACTURING AND SALES, THEIR EMPLOYEES OR REPRESENTATIVES, WILL NOT BE RESPONSIBLE FOR ANY DAMAGES TO GREENHOUSE COVERINGS, STRUCTURES, CROPS OR EQUIPMENT WHEN USED IN CONDUCTION WITH OUR TUBE - LOCK, OR ANY OTHER LOCKING DEVICE MANUFACTURED
BY CONLEY'S MANUFACTURING AND SALES OR OTHERS.
MAKE YOUR CLAIM PROMPTLY, THE TRANSPORTATION COMPANY WILL NOT CONSIDER A CLAIM
UNLESS IT IS PRESENTED WITHIN (9) MONTHS FROM THE DATE OF SHIPMENT. CARRIERS AGENT WILL
ASSIST YOU IN PREPARING A CLAIM.
CLAIMS FOR LOSS OR DAMAGE AND TRANSPORTATION CHARGES RESULTING FROM SHIPPING, MUST NOT BE DEDUCTED FROM THE INVOICE, NOR PATENT INVOICES WITH HELD AWAITING ADJUSTMENT OF SUCH CLAIMS, SINCE IT IS THE FUNCTION OF THE CARRIER TO GUARANTEE SAFE DELIVERY.
CHECK THE ITEMS RECEIVED WITH THE INVOICE. OF THERE IS ANY DISCREPANCY CONTACT US IMMEDIATELY GIVING FULL PARTICULARS. CLAIMS FOR SHORTAGE ATTRIBUTED TO OUR COUNT IN
PACKAGE MUST BE MADE WITHIN 10 DATES FORM THE SHIPMENT IS RECEIVED.
NO MERCHANDISE MAY BE RETURNED FOR CREDIT WITHOUT A RETURN GOODS TAG AND SHIPPING
INSTRUCTIONS FROM THE FACTORY.
WARRANTY
CONLEY'S MANUFACTURING AND SALES, PROVIDE INSTALLATION INSTRUCTIONS AND PRINTS ARE GEARED TOWARDS A QUALIFIED BUILDER WITH PRIOR GREENHOUSE BUILDING EXPERIENCE. IF A QUALIFIED BUILDER IS NOT AVAILABLE, CONLEY'S CAN SUPPLY AT AN ADDITIONAL CHARGE, A FACTORY TRANINED SUPERVISOR TO ASSIST LOCAL CREWS, OR ALTERNATIVELY, AT AN ADDITIONAL
CHARGE SUPPLY A CREW TO COMPLETE THE INSTALLATION OF MATERIALS.
NOTATION OF INSTRUCTIONS PROVIDED
GRADE AND PREPARE THE BUILDING SITE
LAYOUT AND SQUARE THE FOUNDATION
SEE PAGE 7 FOR GUTTER CONNECTED HOUSES
FIGURE 1 - LOCATING CORNER POINT 2
1. REMOVE THE GRASS AND DEBRIS DOWN TO SOLID SOIL.
2. LOCATE THE BUILDING CORNERS AND SET THE GRADING STAKES 5' BEYOND THE CORNERS.
3. A TRANSIT LEVEL IS NEEDED TO SURVEY THE AREA OF THE BUILDING. IN ORDER TO INSURE PROPER DRAINAGE AND EVEN HEATING, THE WIDTH SHOULD BE SET LEVEL AND THE LENGTH SHOULD BE SET LEVEL WITHIN APPROXIMATELY 1%. WITH A LEVEL GRADE, THE COLUMNS WILL NEED TO BE SET AT DIFFERENT HEIGHTS TO ACHIEVE A SLOPE FOR THE GUTTERS TO DRAIN (BUILDINGS WITH GUTTERS ONLY, SEE FIG 9). THE GRADE COULD ALSO BE PREPARED AT A 1/2 % SLOPE, FOR GUTTER BUILDINGS AND THE
COLUMNS CAN ALL BE SET AT THE SAME HEIGHT (SEE SHT 7 FOR OPTIONS)
4. CUT AND FILL THE SITE UNTIL IT IS AT THE RECOMMENDED GRADE.
1. ROUGHLY LOCATE THE CORNERS OF THE BUILDING AND DRIVE IN THE CORNER STAKES.
2. SET BATTER BOARDS APPROXIMATELY 6' ( OR ADEQUATE DISTANCE FROM AUGER CLEARANCE)
BACK FROM THE CORNERS IN EACH DIRECTION. SET INTERMEDIATE BATTER BOARDS OF THE
BUILDING IS LONGER THAN 50' TO KEEP THE LINES FROM SAGGING OR BLOWING IN THE WIND.
3. LOCATE THE FIRST BUILDING CORNER POINT AND MARK IT WITH A STAKE OR NAIL HEAD.
4. MEASURE FROM CORNER POINT 1, THE SPECIFIED DIMENSION OF THE BUILDING, TO LOCATE CORNER POINT 2. PULL A TIGHT LINE BETWEEN BATTER BOARD "1A" AND BATTER BOARD "2A", MAKING SURE THE LINE PASSES OVER CORNER POINT 1 AND CORNER POINT 2. FASTEN THE LINE ONTO THE BATTER BOARDS AND CHECK IT WITH TRANSIT. MAKE SURE THE BATTER BOARDS AND LINES ARE LEVEL (SEE FIG. 1). VARIATIONS IN THIS WILL ULTIMATELY AFFECT THE EAVE HEIGHT.
AutoCAD SHX Text 1A
AutoCAD SHX Text 1B
AutoCAD SHX Text 2B
AutoCAD SHX Text 2A
AutoCAD SHX Text
CORNER POINT 1
AutoCAD SHX Text
FIRST LOCATE BUILDING CORNER AND PLACE TRANSIT DIRECTLY OVER THE CORNER STAKE
AutoCAD SHX Text
CORNER POINT 2
AutoCAD SHX Text
LOCATE STRING LINE FOR THIS CORNER
AutoCAD SHX Text
CORNER POINT 4
AutoCAD SHX Text 4B
AutoCAD SHX Text 4A
AutoCAD SHX Text 3B
AutoCAD SHX Text 3A
AutoCAD SHX Text
MEASURE BUILDING CENTERLINE LENGTH
AutoCAD SHX Text
CORNER POINT 3
MEASURE BUILDING WIDTH
FIGURE 3 - (DIAGONAL METHOD)
FIGURE 4 - (TRIANGLE METHOD)
5. TO LOCATE THE THIRD CORNER POINT (FIG 2), YOU MAY USE ONE OF TWO METHODS, THE DIAGONAL
METHOD OR THE TRIANGLE METHOD.
THE DIAGONAL METHOD - RUN A LINE DIAGONALLY ACROSS FROM CORNER TO CORNER AND
ADJUST THE LINES UNTIL THE DIAGONAL DIMENSIONS ARE EQUAL. (SEE FIGURE 3).
THE TRIANGLE METHOD - CREATE A 90 ANGLE FROM THE FIRST LINE USING CORNER POINT 1 AS A
VERTEX. THIS ANGLE MAY BE ACCOMPLISHED BY USING TWO TAPE MEASURES AND THE CHART
LISTED BELOW (SEE FIGURE 4) (USE THIS METHOD FRO LARGER BUILDINGS WHERE THE LENGTH OF THE DIAGONAL EXCEEDS THE 100 FOOT TAPE MEASURE). WHEN YOU'VE LOCATED CORNER POINT 3, PULL YOUR SECOND LINE BETWEEN BATTER BOARD "1B" AND BATTER BOARD "3B" MAKING SURE IT PASSES OVER CORNER POINT 1 AND CORNER POINT 3. CHECK WITH TRANSIT MAKING SURE THAT
BATTER BOARDS AND LINES ARE LEVEL (SEE FIG. 2.)
FIGURE 2 - (LOCATING CORNER POINT 3)
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text 2A
AutoCAD SHX Text 2B
AutoCAD SHX Text 3A
AutoCAD SHX Text 3B
AutoCAD SHX Text 1A
AutoCAD SHX Text 1B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DIMENSION A + DIMENSION B + DIMENSION C
AutoCAD SHX Text 2 2 2
AutoCAD SHX Text 20' 15' 25'
AutoCAD SHX Text 24' 18' 30'
AutoCAD SHX Text 28' 21' 35'
AutoCAD SHX Text 32' 24' 40'
AutoCAD SHX Text 36' 27' 45'
AutoCAD SHX Text 40' 30' 50'
CORNER POINT 2
AutoCAD SHX Text
CORNER POINT 1
AutoCAD SHX Text
STRING LINE LOCATION FOR THIRD CORNER
AutoCAD SHX Text
CORNER POINT 3
AutoCAD SHX Text MEASURE THE DIAGONAL LINES AND ADJUST THE LINES UNTIL THE TWO DIAGONAL DIMENSIONS ARE EQUAL
CREATE A 90° ANGLE TO LOCATE STRING LINE FOR THIRD CORNER
FIGURE 6 - (LOCATING COLUMN CENTERS)
FIND COLUMN CENTERS
6. TO LOCATE THE FOURTH CORNER POINT (FIGURE 5), USING TWO TAPE MEASURES, FROM CORNER POINT 3 AND CORNER POINT 2, THE SPECIFIED LENGTH AND WIDTH. THE POINT AT WHICH THESE
LINES INTERSECT WILL BE CORNER POINT 4.
7. NOW YOU MAY PULL YOUR LAST TWO LINES AND FASTEN THEM TO THE APPROPRIATE BATTER
BOARDS. BE SURE TO CHECK THE LEVEL OF YOUR LINES (FIGURE 5).
1. MARK THE CORNER POINTS ON THE LINES, AND USE A 100 FOOT TAPE MEASURE TO MARK THE
INTERMEDIATE HOLE CENTERS ON THE LINES.
2. USING A LEVEL FOR VERTICAL ACCURACY, MARK THE HOLE CENTERS ON THE GROUND WITH NAILS.
PAINT THE NAIL HEADS WITH FLUORESCENT PAINT.
3. MEASURE DOWN THE WIDTH OF THE LINES AND MARK THE END WALL UPRIGHT CENTERS IN THE
SAME MANNER.
FIGURE 5 - (LOCATING CORNER POINT 4)
AutoCAD SHX Text 2A
AutoCAD SHX Text 2B
AutoCAD SHX Text 1A
AutoCAD SHX Text 1B
AutoCAD SHX Text 4A
AutoCAD SHX Text 4B
AutoCAD SHX Text 3B
AutoCAD SHX Text 3A
AutoCAD SHX Text
CORNER POINT 4
AutoCAD SHX Text
CORNER POINT 2
AutoCAD SHX Text
MEASURE BUILDING WIDTH
AutoCAD SHX Text
CORNER POINT 1
AutoCAD SHX Text
CORNER POINT 3
AutoCAD SHX Text
MEASURE BUILDING CENTERLINE LENGTH
AutoCAD SHX Text
PAINTED NAILS
AutoCAD SHX Text
MARK COLUMN CENTERS AT 4'-0", 5'-0", OR 6'-0" (SEE QUOTE / SALES ORDER)
AutoCAD SHX Text
6 INCHES (OR DESIRED STRING HEIGHT)
AutoCAD SHX Text
COLUMN CENTERLINES
MARK END WALL UPRIGHT CENTERS AT 10'-0"
CAUTION
BE SURE THERE ARE NO UNDERGROUND OR
OVERHEAD ELECTRICAL WIRES, WATER PIPES,
GAS LINES, ETC...ON OR NEAR THE JOB SITE.
FIGURE 7 - (AUGER HOLE)
FIGURE 8 - (OFFSETTING OF THE COLUMN SET LINES)
AUGER COLUMN HOLES
OFFSETTING THE LINES
1. AT THE POINT THAT THE LINES MEET THE BATTER BOARDS, CLEARLY AND ACCURATELY MARK THE
PLACEMENT OF THE LINES. MAKE SURE ALL THE BATTER BOARDS ARE MARKED.
2. REMOVE THE LINES.
3. AUGER HOLES TO REQUIRED DIMENSIONS.
4. AFTER DIGGING THE HOLES FOR END WALL UP RIGHTS, REFILL LOOSELY WITH DIRT, UNTIL READY
FOR USE, (SEE FIGURE 9-PAGE 7).
1. OFFSETTING OF THE LINES SHOULD BE DONE THE DAY THE CONCRETE IS POURED AND NOT LEFT
OVERNIGHT TO PREVENT STRETCHING OR KNOCKING DOWN LINES.
2. TO FIND THE COLUMN SET LINES, YOU MUST RESTRING THE FOUNDATION LAYOUT. FROM THE CENTER LINE MARKS ON THE BATTER BOARDS, MEASURE 1/2 THE SIZE OF THE COLUMN AND MOVE
THE LINES TO THAT MARK. (ALWAYS MOVE THE LINES IN THE SAME DIRECTION TO PREVENT
CONFUSION AND MISPLACEMENT OF COLUMNS (SEE FIGURE 8).
AutoCAD SHX Text
DEPTH
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
PREFERRED STRING HEIGHT (HEIGHT CHOSEN MUST NOT VARY THROUGHOUT LAYOUT)
AutoCAD SHX Text
OFFSET 1/2 OF COLUMN SIZE
AutoCAD SHX Text
END STRINGS FOR START/END POINT
AutoCAD SHX Text
COLUMN SET LINE MOVED TO RIGHT
ORIGINAL CENTERLINE MARK
SLOPE LINES
MARK CENTERS ON COLUMNS
NOTE: THIS TECHNIQUE TO BE USED WITH GUTTER HOUSES ONLY
FIGURE 9 - SLOPING COLUMN LINES
1. FROM THE CENTER LINE, MARK ON THE BATTER BOARDS (NOT THE COLUMN SET MARK) THE LENGTH OF LINES, AND
MARK THE INTERMEDIATE CENTERS.
2. MARK THE END WALL UPRIGHTS IN THE SAME MANNER. PLEASE NOTE THAT THE OFFSETS FOR END WALL INTERMEDIATE COLUMNS MAY BE DIFFERENT THAN THE OFFSET OF THE SIDE WALL COLUMNS DUE TO THE DIFFERENCE IN COLUMN SIZE. THE CENTER LINES OF COLUMNS MUST BE THE CENTER LINE END WALL COLUMNS.
1. IF SLOPING THE GRADE IS NOT DESIRED, THE THE SLOPE CAN BE ACHEIVED BY SETTING THE COLUMNS AT SPECIFIC HEIGHTS ALONG THE LENGTH OF THE BUILDING. PLEASE NOTE THAT THE UNDER GUTTER (UG) HEIGHT OF THE BUILDING IS MEANT TO BE FOR THE HIGH SIDE OF THE BUILDING (THE PEAK UG HEIGHT AT THE CENTER OF THE
BUILDING FOR LONGER THAN 300' BUILDINGS).
SLOPE THE COLUMN LINES ALONG THE LENGTH OF THE FOUNDATION KEEPING THE FRONT AND BACK COLUMN
LINES PARALLEL. THIS WILL INSURE PROPER DRAINAGE (SEE FIG. 9).
SLOPING "GUTTER BUILDINGS" FOR
PROPER WATER DRAINAGE
1. IT IS PREFERRED TO SLOPE THE GRADE FOR WATER DRAINING (GUTTERED) GREENHOUSES. SLOPE THE GRADE ALONG THE LENGTH OF THE FOUNDATION KEEPING THE FRONT AND BACK COLUMN LINES PARALLEL. A SLOPE OF 3/4" EVERY 12'-0" (APPROXIMATELY 1/2 % SLOPE) WILL INSURE PROPER DRAINAGE AT THE GUTTERS. IF THIS OPTION IS CHOSEN, THEN ALL COLUMNS CAN BE SET TO THE SAME HEIGHT, AND BE ABLE TO ACHIEVE A CONSTANT BUILDING HEIGHT. IF THE BUILDING IS VERY LONG (OVER 300' LONG), IT IS ADVISABLE TO HAVE THE PEAK AT THE CENTER OF THE BUILDING, AND HAVE (2) OUTLETS, (1) AT EACH THE END WALL. THIS DETERMINATION WILL NORMALLY BE
TAKEN CARE OF BY THE DESIGN TEAM AT CONLEY'S.
AutoCAD SHX Text
SLOPE COLUMN LINE 1/2% APPROX. (0R 3/4" DROP EVERY 12'-0) TYPICAL BOTH SIDES
FRONT AND BACK COLUMN LINES TO REMAIN PARALLEL
MARK COLUMNS
SET COLUMNS
FIGURE 10 - (MARKING COLUMNS)
FIGURE 11 - (SETTING THE COLUMNS)
1. TO FIND THE ABOVE GROUND COLUMN HEIGHT, MEASURE FROM THE TOP OF THE COLUMN, THIS DISTANCE, AND SUBTRACT THE STRING HEIGHT. MARK THE COLUMN AT THIS POINT WITH A FELT TIP
MARKER. CONTINUE WITH REMAINING COLUMNS. (SEE FIGURE 10).
1. POUR CONCRETE INTO THE FIRST HOLE. (2) 1/2" SLUMP IS THE MOST POPULAR MIX TO SUPPORT
COLUMNS.
2. PUSH THE COLUMN INTO THE CONCRETE AT THE CENTER MARK ON THE STRING (BE SURE THE COLUMN ISN'T ACTUALLY TOUCHING STRING) UNTIL THE MARK ON COLUMN LINES UP WITH THE
STRING. THE COLUMN MUST BE PLUMB IN BOTH DIRECTIONS BEFORE MOVING ON TO THE NEXT
COLUMN.
3. MOVE ON TO THE NEXT COLUMN, POUR CONCRETE THEN SET THE COLUMN. NEVER POUR ALL THE
CONCRETE FIRST THEN GO BACK AND SET COLUMNS, AS THE CONCRETE SETS UP TOO FAST.
1. PLACE THE FIRST THREE ARCHES INTO THE FIRST THREE AUGURED HOLES. (SEE PAGE 6 FOR HOLE
AUGURING).
AutoCAD SHX Text
STRING HEIGHT
AutoCAD SHX Text
CAUTION:
AutoCAD SHX Text
ABOVE GROUND COLUMN HEIGHT MINUS STRING HEIGHT
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
AUGER HOLE
AutoCAD SHX Text
HOLES FOR COLUMNS
AutoCAD SHX Text
COLUMN SET IN CONCRETE ON CENTER
AutoCAD SHX Text
HOLES FOR END WALL UPRIGHT PIPERS
AutoCAD SHX Text
COLUMN SET LINES
AutoCAD SHX Text
STRING AND MARK ON COLUMN TO BE LINED UP
AutoCAD SHX Text
LEVEL
AutoCAD SHX Text
COLUMN SET LINE
CONCRETE
COLUMN TO ARCH CONNECTOR
INSTALLATION OF ARCHES
1. ATTACH THE FIRST ARCH TO THE CONNECTORS USING (4) 1/4 X 3/4" MACHINE BOLTS.
NOTE: DO NOT INSTALL THE MIDDLE BOLT.
1. ATTACH THE CONNECTOR TO THE COLUMNS USING 1 CLAMP AND (2) 3/8" X 1" MACHINE BOLTS PER
CONNECTOR.
AutoCAD SHX Text CONNECTOR COLUMN TO ARCH CLAMP (1 5/8" COLUMN) #C0155451 (2 7/8" COLUMN) #C0155501
AutoCAD SHX Text
(2) 3/8" HEX NUT #N9970300
AutoCAD SHX Text COLUMN TUBE 1 5/8" or 2 7/8"
AutoCAD SHX Text
(2) 3/8" X 1" MACHINE BOLT #B9970440
AutoCAD SHX Text CONNECTOR COLUMN TO ARCH HAND (1 5/8" COLUMN) #C0155450 (2 7/8" COLUMN) #C0155500
AutoCAD SHX Text
BOLT TWO ARCHES TOGETHER
AutoCAD SHX Text
(2) 1/4" X 3/4" MACHINE BOLT #B9970030
AutoCAD SHX Text
COLUMN CONNECTION
AutoCAD SHX Text
(2) 1/4" HEX NUT #N9970280
AutoCAD SHX Text
CHORD ARCH (20' ARCH #C0055351) (24' ARCH #C0055356)
14-14 X 1" TEK SCREW #S9970052
FIGURE 12 - (ARCH ASSEMBLY)
1. TIE OFF THE ARCH USING ROPES OR CABLES TO MAKE THE ARCH PLUMB AND SQUARE.
(MATERIALS FOR SECURING THE COLUMNS, ROPE / CABLE, IS NOT SUPPLIED BY CONLEY'S
MANUFACTURING SALES).
2. BOLT TWO MORE ARCHES TO THE LEGS USING (4) 1/4" X 3/4" MACHINE BOLTS PER ARCH.
FIGURE 13 - (ARCH ASSEMBLY)
PURLIN INSTALLATION
AutoCAD SHX Text 4', 5', or 6' CENTER TO CENTER
4', 5', or 6' CENTER TO CENTER
3. BOLT THE RIDGE PURLIN TO THE UNDERSIDE OF THE FIRST AND SECOND ARCHES USING (2) 1/4" X 3/4"
MACHINE BOLTS PER ARCH.
4. BOLT ON THE QUARTER POINT PURLINS TO THE FIRST AND SECOND ARCHES USING (2) 1/4" X 3/4"
MACHINE BOLTS PER ARCH.
5. ATTACH TWO MORE ARCHES. OVERLAP THE RIDGE PURLIN AT THE THIRD ARCH AND BOLT IT TO THE
THIRD AND FOURTH ARCHES WITH (2) 1/4" X 3/4" MACHINE BOLTS PER ARCH.
6. OVERLAP THE QUARTER POINT PURLINS AT THE THIRD ARCH AND BOLT THEM TO THE THIRD AND
FOURTH ARCHES.
AutoCAD SHX Text
3" PURLIN #P0001715
AutoCAD SHX Text
CHORD ARCH
AutoCAD SHX Text
(2) 1/4" X 3/4" MACHINE BOLT #B9970030
AutoCAD SHX Text
5" PURLIN #P0001840
AutoCAD SHX Text
CHORD ARCH
AutoCAD SHX Text
(2) 1/4" X 3/4" MACHINE BOLT #B9970030
AutoCAD SHX Text
RIDGE PURLIN
AutoCAD SHX Text
SIDE PURLINS
CHORD ARCH
FIGURE 15 - (" X " BRACING)
FIGURE 14 - (INSTALLING THE REMAINING PURLINS)
1. INSTALL THE REMAINING ARCHES, TWO AT A TIME, UNTIL THE FULL LENGTH OF THE BUILDING IS
COMPLETE.
1. BRACE STRAPS ARE INSTALLED AT EACH END OF THE BUILDING IN THE SECOND BAY. ADJUST THE
ARCHES UNTIL THEY ARE PLUMB AND SQUARE.
2. TRIM IF NEEDED.
INSTALL REMAINING ARCHES AND PURLINS
INSTALL "X" BRACING
AutoCAD SHX Text
ARCHES AT 6'-0" ON CENTER
AutoCAD SHX Text
PURLINS
AutoCAD SHX Text
"X" BRACING
4', 5', or 6' CENTER TO CENTER
3. USING A 10-16 X 3/4" SCREW AT EACH END OF THE BRACE STRAP, SCREW ONE END AT THE END OF THE
SECOND ARCH AND THE OPPOSITE END TO THE UNDERSIDE OF THE THIRD ARCH BELOW THE
QUARTER POINT PURLIN.
4. SCREW ON THE SECOND STRAP THE SAME WAY AS THE FIRST SO THAT THE STRAPS FORM AN "X".
REPEAT THIS AT THE REMAINING THREE LOCATIONS IN BUILDING.
AutoCAD SHX Text
ARCH
AutoCAD SHX Text
CHORD ARCH
AutoCAD SHX Text
BRACE STRAP 8' #B0001891
AutoCAD SHX Text
1ST PURLIN
AutoCAD SHX Text
(2) 10-16 X 3/4" TEK SCREW #S9970010
AutoCAD SHX Text
BRACE STRAP 8' #B0001891
AutoCAD SHX Text
(2) 10-16 X 3/4" TEK SCREW #S9970010
(2) 1/4" X 3/4" MACHINE BOLT #B9970030
FIGURE 16 - (WOOD GIRT INSTALLATION)
1. ATTACH THE 2 X 4 GIRT TO THE COLUMN
AND 2 X 4 SPLICE AS SHOWN BELOW.
NOTE: CONLEY'S MFG. DOES NOT SUPPLY
ANY LUMBER - THE CUSTOMER MUST
PURCHASE ALL LUMBER AND NAILS.
2. IF YOU HAVE PURCHASED THE PIPE CLAMP
AND HARDWARE FROM CONLEY'S MFG., THEN
YOU NEED TO DRILL A 5/16" HOLE FOR A
1/4" X 2" CARRIAGE BOLT 2 1/2" FROM THE
END OF THE GIRT FOR A 2 7/8" COLUMN OR
1 1/2" FROM THE END FOR A 1 5/8" COLUMN.
NOTE:
THIS DRAWING IS FOR REFERENCE
ONLY!!! CONLEY'S MFG. ONLY SUPPLIES
THE CLAMP ASSEMBLY WHEN ORDERED
BY THE CUSTOMER. ALL OTHER MATERIAL
MUST BE SUPPLIED BY THE CUSTOMER.
GIRT INSTALLATION
NOTE:
IF THE KOOL CEL DISTRIBUTION SYSTEM IS BEING INSTALLED, CHECK THE KOOL CEL INSTRUCTION
MANUAL FOR PROPER SLOPE AND DISTANCE TO INSTALL END WALL OR SIDE WALL GIRTS.
1. MARK THE COLUMNS WITH THE GIRT LOCATIONS.
2. CLAMP THE GIRTS TO THE COLUMN AND ADJUST
TO MAKE THEM LEVEL.
3. SECURE THE GIRTS TO THE COLUMNS WITH
(2) 14-14 X 1" TEK SCREWS PER COLUMN.
4. SPICE THE GIRTS BY OVERLAPPING THEM AND
SECURING BOTH GIRTS TO THE COLUMN
WITH (2) 14-14 X 1" TEK SCREW PER COLUMN.
FIGURE 16A - (METAL GIRT INSTALLATION)
DETAIL 1
DETAIL 2
DETAIL 3 - TOP KOOL CEL GIRT
TOP VIEW SPLICE
TOP VIEW SPLICE @ CORNERS
KOOL
CEL
GIRT
COLUMN
SPLICE PLATE
#S0000950
KOOL
CEL
GIRT
COLUMN
SIDE VIEW
KOOL
CEL
GIRT
ARCH
HAND
AutoCAD SHX Text
PIPE CLAMP
AutoCAD SHX Text
(2) 1/4" X 2" CARRIAGE BOLTS
AutoCAD SHX Text
2 X 4 GIRT
AutoCAD SHX Text
2 X 4 SPLICE
AutoCAD SHX Text
COLUMNS AT 6'-0" ON CENTER (THIS EXAMPLE ONLY)
AutoCAD SHX Text
COLUMN TUBE
AutoCAD SHX Text
14-14 X 1" TEK SCREW #S9970052
AutoCAD SHX Text
GIRT 5" #G0000XXX
AutoCAD SHX Text
OVERLAP GIRT 4"
AutoCAD SHX Text
14-14 X 1" TEK SCREW #S9970052
AutoCAD SHX Text
COLUMN
GIRT 5" #G0000XXX
DETAIL 1
FIGURE 17 - (END WALL DOOR FRAME)
1. DIG HOLES AT THE CENTER LINE OF JAMBS. THE DISTANCE BETWEEN THE JAMBS IS DETERMINED BY
THE DOORS WIDTH.
2. DOOR JAMBS DOESN'T HAVE TO GO ALL THE WAY UP TO THE ARCH. ENDWALL GIRTS MAY VARY ON YOUR
SIDEWALL HEIGHT.
2. ATTACH THE END WALL UPRIGHTS TO THE ARCH TAB WITH (2) 1/4" X 3/4" MACHINE BOLTS.
3. STAND THE DOOR JAMBS IN THE HOLES AND ATTACH IT TO THE TOP OF THE JAMB AND TO THE PREVIOUSLY INSTALLED TAB. ALIGN THE JAMB FLUSH WITH THE OUTSIDE EDGE OF THE ARCH AND
CONNECT IT TO THE TAB WITH (2) 3/8" X 1" MACHINE BOLT.
DOOR END WALL WITH METAL GIRTS
AutoCAD SHX Text
1/4" HEX NUT #N9970280
AutoCAD SHX Text
1/4" X 3/4" MACHINE BOLTS #B9970030
AutoCAD SHX Text
3/8" X 1" MACHINE BOLTS #B9970440
AutoCAD SHX Text
END WALL UPRIGHT TO ARCH TAB #T0030870
AutoCAD SHX Text
3/8" HEX NUT #N9970300
AutoCAD SHX Text
DOOR JAMB #J0000101 #J0000111
AutoCAD SHX Text
END WALL ARCH
AutoCAD SHX Text
DOOR HEADER
AutoCAD SHX Text
END WALL GIRT
AutoCAD SHX Text
END WALL GIRT
AutoCAD SHX Text
TAB
AutoCAD SHX Text
TAB
AutoCAD SHX Text
JAMB
AutoCAD SHX Text
JAMB
AutoCAD SHX Text
END WALL UPRIGHT
AutoCAD SHX Text
TAB
AutoCAD SHX Text
TAB
AutoCAD SHX Text
COLUMN
AutoCAD SHX Text
COLUMN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NOTE: HOW MANY SIDEWALL GIRTS DEPENDS ON YOUR SIDEWALL HEIGHT.
DETAIL 2
4. PLUMB JAMBS IN BOTH DIRECTIONS AND CEMENTS THE HOLES OR FILL THEM WITH CRUSHED ROCK
DEPENDING ON YOUR BUILDING. (SEE PAGE 15 FOR INFORMATION).
5. DRILL SCREW THE END WALL / HEADER JAMB TAB TO THE END WALL ARCH, JAMBS, AND AT THE HEADER WITH (2) 14-14 X 1" TEK SCREWS. (SEE PAGE 15 FOR TAB / GIRT / HEADER LOCATIONS).
6. LEVEL AND DRILL SCREW THE END GIRTS TO THE TABS AND INSIDE OF DOOR JAMBS WITH (2)
14-14 X 1" TEK SCREWS AT TAB JAMBS.
DETAIL 3
AutoCAD SHX Text
END WALL ARCH
AutoCAD SHX Text
(4) 14-14 X 1" TEK SCREWS #S9970052
AutoCAD SHX Text
END GIRT SEE MATERIAL SHIPPING LIST FOR PART NUMBERS
AutoCAD SHX Text
END WALL / HEADER TO JAMB TAB #T0030880
AutoCAD SHX Text
DOOR SLIDING JAMB #J0000101 #J0000110
AutoCAD SHX Text
(4) 14-14 X 1" TEK SCREWS #S9970052
AutoCAD SHX Text
END WALL / HEADER TO JAMB TAB #T0030880
AutoCAD SHX Text
HEADER GIRT (USE GIRT FOR YOUR DOOR HEADER)
AutoCAD SHX Text
(2) 14-14 X 1" TEK SCREW #S9970052
END GIRT SEE MATERIAL SHIPPING LIST FOR PART NUMBER
DETAIL 4
FIGURE 18 - (SOLID END WALL)
SOLID END WALL WITH METAL GIRTS
1. FOLLOW DIRECTIONS 1, 2, 4, AND 5 ON PAGES 15, 16, 17 AND 18 FOR END WALL INSTALLATION.
2. LEVEL AND DRILL SCREW THE END GIRTS TO THE TABS WITH (2) 14-14 X 1" TEK SCREWS AT EACH TAB.
REFER TO PAGE 20 AND 23 FOR GIRT AND END WALL UPRIGHT LOCATIONS.
3. SECURE THE END GIRTS TO THE END WALL UPRIGHTS WITH (2) 14-14 X 1" TEK SCREWS.
(SEE DETAIL 4 BELOW).
AutoCAD SHX Text
(2) 14-14 X 1" TEK SCREW #S9970052
AutoCAD SHX Text
JAMB / END WALL UPRIGHT #J0000101 #J0000111
AutoCAD SHX Text
END GIRT SEE MATERIAL SHIPPING LIST FOR PART NUMBER
AutoCAD SHX Text
END WALL GIRT
AutoCAD SHX Text
END WALL GIRT
AutoCAD SHX Text
TAB
AutoCAD SHX Text
COLUMN
AutoCAD SHX Text
JAMB
AutoCAD SHX Text
JAMB
AutoCAD SHX Text
TAB
AutoCAD SHX Text
COLUMN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DETAIL 5 (OPTION A -TAB)
DETAIL 5 (OPTION B - NO TAB)
AutoCAD SHX Text
5" ENDWALL GIRT
AutoCAD SHX Text
#14 X 1" TEK SCREW #S9970052
AutoCAD SHX Text
TAB #T0030880
AutoCAD SHX Text
COLUMN 2-7/8"
AutoCAD SHX Text USE: #14 X 1" TEK SCREW #S9970052 WHEN #14 X 1" RUNS OUT, #10 X 3/4" OR #10 X 1-1/4" CAN BE USED
AutoCAD SHX Text
JAMB/ END WALL UPRIGHT
AutoCAD SHX Text
#10 X 3/4" OR #10 X 1-1/4"
AutoCAD SHX Text
5" ENDWALL GIRT
AutoCAD SHX Text
#14 X 1" TEK SCREW #S9970052
AutoCAD SHX Text
COLUMN 2-7/8"
AutoCAD SHX Text USE: #14 X 1" TEK SCREW #S9970052 WHEN #14 X 1" RUNS OUT, #10 X 3/4" OR #10 X 1-1/4" CAN BE USED
AutoCAD SHX Text
JAMB/ END WALL UPRIGHT
#10 X 3/4" OR #10 X 1-1/4"
FIGURE 19 - (ARCH PARTS LIST)
20'-0" COLD FRAME WITH LEGS
ARCH PARTS LIST
ITEM QTY PART No. DESCRIPTION
BRACE STRAP 8'-0"1 4 B0001891
C0155451
B9970440
N9970280
P0001715 P0001840 S9970010
CONN. COLUMN TO ARCH CLAMP
BOLT / HH 3/8" X 1"
COLUMN TUBE T-44 1 5/8"
PURLIN 3" X 12'-4" SIDES
NUT HEX PLTD COARSE 1/4"
PURLIN 5" X 12'-4" UNDER RIDGE
10-16 X 3/4" TEK SCREW
B9970030 BOLT / HH 1/4" X 3/4" GRADE 514
N9970300 NUT HEX PLTD COARSE 3/8"4
C0055351 CHORD ARCH 154" RAD2
C0155450 CONN COLUMN TO ARCH HAND 1-5/82
ITEM QTY PART No. DESCRIPTION
BRACE STRAP 8'-0"1 4 B0001891
C0155501
B9970440
N9970280
P0001715 P0001840 S9970010
CONN. COLUMN TO ARCH CLAMP
BOLT / HH 3/8" X 1"
COLUMN TUBE T-22 2 7/8"
PURLIN 3" X 12'-4" SIDES
NUT HEX PLTD COARSE 1/4"
PURLIN 5" X 12'-4" UNDER RIDGE
10-16 X 3/4" TEK SCREW
B9970030 BOLT / HH 1/4" X 3/4" GRADE 514
N9970300 NUT HEX PLTD COARSE 3/8"4
C0055351 CHORD ARCH 154" RAD2
C0155500 CONN COLUMN TO ARCH HAND 2-7/82
1 5/8 COLUMN (PARTS LIST)
2 7/8 COLUMN (PARTS LIST)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIGURE 20 - (END WALL PARTS LIST)
20'-0" COLD FRAME WITH LEGS
END WALL PARTS LIST
ITEM QTY PART No. DESCRIPTION
C0155451
B9970440
N9970280
P0001715 P0001840 S9970010
CONN. COLUMN TO ARCH CLAMP 1-5/8
BOLT / HH 3/8" X 1"
COLUMN TUBE T-44 1 5/8"
PURLIN 3" X 12'-4" SIDES
NUT HEX PLTD COARSE 1/4"
PURLIN 5" X 12'-4" UNDER RIDGE
10-16 X 3/4" TEK SCREW
B9970030 BOLT / HH 1/4" X 3/4" GRADE 516
N9970300 NUT HEX PLTD COARSE 3/8"8
C0055351 CHORD ARCH 154" RAD2
C0155450 CONN COLUMN TO ARCH HAND2
14 T0030870
T0030880
TAB END WALL UPRIGHT
TAB END WALL / HEADER TO JAMB
G0000200 GIRT 5" X 20'-0"2
J0000101 SLIDING DOOR JAMB 10'-0"2
ITEM QTY PART No. DESCRIPTION
C0155501
B9970440
N9970280
P0001715 P0001840 S9970010
CONN. COLUMN TO ARCH CLAMP
BOLT / HH 3/8" X 1"
COLUMN TUBE T-22 2 7/8"
PURLIN 3" X 12'-4" SIDES
NUT HEX PLTD COARSE 1/4"
PURLIN 5" X 12'-4" UNDER RIDGE
10-16 X 3/4" TEK SCREW
B9970030 BOLT / HH 1/4" X 3/4" GRADE 516
N9970300 NUT HEX PLTD COARSE 3/8"8
C0055351 CHORD ARCH 154" RAD2
C0155500 CONN COLUMN TO ARCH HAND 2-7/82
14 T0030870
T0030880
TAB END WALL UPRIGHT
TAB END WALL / HEADER TO JAMB
G0000200 GIRT 5" X 20'-0"2
J0000111 SLIDING DOOR JAMB 10'-0"2
1 5/8 COLUMN - (END WALL PARTS LIST)
2 7/8 COLUMN - (END WALL PARTS LIST)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ADJUST FOR
DOOR SIZE
SUPPLIED
WITH DOOR
20'-0" COLD FRAME WITH LEGS
END WALL WITH DOOR PARTS LIST
FIGURE 21 - (END WALL PARTS LIST)
ITEM QTY PART No. DESCRIPTION
C0155451
B9970440
N9970280
P0001715 P0001840 S9970010
CONN. COLUMN TO ARCH CLAMP
BOLT / HH 3/8" X 1"
COLUMN TUBE T-44 1 5/8"
PURLIN 3" X 12'-4" SIDES
NUT HEX PLTD COARSE 1/4"
PURLIN 5" X 12'-4" UNDER RIDGE
10-16 X 3/4" TEK SCREW
B9970030 BOLT / HH 1/4" X 3/4" GRADE 516
N9970300 NUT HEX PLTD COARSE 3/8"8
C0055351 CHORD ARCH 154" RAD2
C0155450 CONN COLUMN TO ARCH HAND 1-5/82
T0030870 T0030880
TAB END WALL UPRIGHT
TAB END WALL / HEADER TO JAMB
G0000200 GIRT 5" X 20'-0"2
J0000101 SLIDING DOOR JAMB 10'-0"2
J0000111 SLIDING DOOR JAMB 12'-0"2
1 5/8 COLUMN - (END WALL PARTS LIST)
ITEM QTY PART No. DESCRIPTION
C0155501
B9970440
N9970280
P0001715 P0001840 S9970010
CONN. COLUMN TO ARCH CLAMP
BOLT / HH 3/8" X 1"
COLUMN TUBE T-22 2 7/8"
PURLIN 3" X 12'-4" SIDES
NUT HEX PLTD COARSE 1/4"
PURLIN 5" X 12'-4" UNDER RIDGE
10-16 X 3/4" TEK SCREW
B9970030 BOLT / HH 1/4" X 3/4" GRADE 516
N9970300 NUT HEX PLTD COARSE 3/8"8
C0055351 CHORD ARCH 154" RAD2
C0155500 CONN COLUMN TO ARCH HAND 2-7/82
T0030870 T0030880
TAB END WALL UPRIGHT
TAB END WALL / HEADER TO JAMB
G0000200 GIRT 5" X 20'-0"2
J0000101 SLIDING DOOR JAMB 10'-0"2
J0000111 SLIDING DOOR JAMB 12'-0"2
2 7/8 COLUMN - (END WALL PARTS LIST)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIGURE 22 - (ARCH PARTS LIST)
24'-0" COLD FRAME WITH LEGS
ARCH PARTS LIST
ITEM QTY PART No. DESCRIPTION
BRACE STRAP 8'-0"1 4 B0001891
C0155451
B9970440
N9970280
P0001715 P0001840 S9970010
CONN. COLUMN TO ARCH CLAMP
BOLT / HH 3/8" X 1"
COLUMN TUBE T-44 1 5/8"
PURLIN 3" X 12'-4" SIDES
NUT HEX PLTD COARSE 1/4"
PURLIN 5" X 12'-4" UNDER RIDGE
10-16 X 3/4" TEK SCREW
B9970030 BOLT / HH 1/4" X 3/4" GRADE 514
N9970300 NUT HEX PLTD COARSE 3/8"4
C0055356 CHORD ARCH 190" RAD2
C0155450 CONN COLUMN TO ARCH HAND 1-5/82
1-5/8 COLUMN (PARTS LIST)
ITEM QTY PART No. DESCRIPTION
BRACE STRAP 8'-0"1 4 B0001891
C0155501
B9970440
N9970280
P0001715 P0001840 S9970010
CONN. COLUMN TO ARCH CLAMP
BOLT / HH 3/8" X 1"
COLUMN TUBE T-44 2 7/8"
PURLIN 3" X 12'-4" SIDES
NUT HEX PLTD COARSE 1/4"
PURLIN 5" X 12'-4" UNDER RIDGE
10-16 X 3/4" TEK SCREW
B9970030 BOLT / HH 1/4" X 3/4" GRADE 514
N9970300 NUT HEX PLTD COARSE 3/8"4
C0055356 CHORD ARCH 190" RAD2
C0155500 CONN COLUMN TO ARCH HAND 2-7/82
2-7/8 COLUMN (PARTS LIST)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIGURE 23 - (END WALL PARTS LIST)
24'-0" COLD FRAME WITH LEGS
END WALL PARTS LIST
ITEM QTY PART No. DESCRIPTION
C0155451
B9970440
N9970280
P0001715 P0001840 S9970010
CONN. COLUMN TO ARCH CLAMP
BOLT / HH 3/8" X 1"
COLUMN TUBE T-44 1 5/8"
PURLIN 3" X 12'-4" SIDES
NUT HEX PLTD COARSE 1/4"
PURLIN 5" X 12'-4" UNDER RIDGE
10-16 X 3/4" TEK SCREW
B9970030 BOLT / HH 1/4" X 3/4" GRADE 516
N9970300 NUT HEX PLTD COARSE 3/8"8
C0055356 CHORD ARCH 190" RAD2
C0155450 CONN COLUMN TO ARCH HAND 1-5/82
14 T0030870
T0030880
TAB END WALL UPRIGHT
TAB END WALL / HEADER TO JAMB
G0000450 GIRT 5" X 24'-0"2
J0000100 SLIDING DOOR JAMB 10'-0"2
1-5/8 COLUMN - (END WALL PARTS LIST)
ITEM QTY PART No. DESCRIPTION
C0155501
B9970440
N9970280
P0001715 P0001840 S9970010
CONN. COLUMN TO ARCH CLAMP
BOLT / HH 3/8" X 1"
COLUMN TUBE T-44 2 7/8"
PURLIN 3" X 12'-4" SIDES
NUT HEX PLTD COARSE 1/4"
PURLIN 5" X 12'-4" UNDER RIDGE
10-16 X 3/4" TEK SCREW
B9970030 BOLT / HH 1/4" X 3/4" GRADE 516
N9970300 NUT HEX PLTD COARSE 3/8"8
C0055356 CHORD ARCH 190" RAD2
C0155500 CONN COLUMN TO ARCH HAND 2-7/82
14 T0030870
T0030880
TAB END WALL UPRIGHT
TAB END WALL / HEADER TO JAMB
G0000450 GIRT 5" X 24'-0"2
J0000100 SLIDING DOOR JAMB 10'-0"2
2-7/8 COLUMN - (END WALL PARTS LIST)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ADJUST FOR
DOOR SIZE
SUPPLIED
WITH DOOR
24'-0" COLD FRAME WITH LEGS
END WALL WITH DOOR PARTS LIST
FIGURE 24 - (END WALL WITH DOOR PARTS LIST)
ITEM QTY PART No. DESCRIPTION
C0155451
B9970440
N9970280
P0001715 P0001840 S9970010
CONN. COLUMN TO ARCH CLAMP
BOLT / HH 3/8" X 1"
COLUMN TUBE T-44 1 5/8"
PURLIN 3" X 12'-4" SIDES
NUT HEX PLTD COARSE 1/4"
PURLIN 5" X 12'-4" UNDER RIDGE
10-16 X 3/4" TEK SCREW
B9970030 BOLT / HH 1/4" X 3/4" GRADE 516
N9970300 NUT HEX PLTD COARSE 3/8"8
C0055356 CHORD ARCH 190" RAD2
C0155450 CONN COLUMN TO ARCH HAND 1-5/82
T0030870 T0030880
TAB END WALL UPRIGHT
TAB END WALL / HEADER TO JAMB
G0000450 GIRT 5" X 24'-0"2
J0000100 SLIDING DOOR JAMB 10'-0"2
J0000110 SLIDING DOOR JAMB 12'-0"2
1 5/8 COLUMN - (END WALL WITH DOOR PARTS LIST)
ITEM QTY PART No. DESCRIPTION
C0155501
B9970440
N9970280
P0001715 P0001840 S9970010
CONN. COLUMN TO ARCH CLAMP
BOLT / HH 3/8" X 1"
COLUMN TUBE T-44 1 5/8"
PURLIN 3" X 12'-4" SIDES
NUT HEX PLTD COARSE 1/4"
PURLIN 5" X 12'-4" UNDER RIDGE
10-16 X 3/4" TEK SCREW
B9970030 BOLT / HH 1/4" X 3/4" GRADE 516
N9970300 NUT HEX PLTD COARSE 3/8"8
C0055356 CHORD ARCH 190" RAD2
C0155500 CONN COLUMN TO ARCH HAND 2-7/82
T0030870 T0030880
TAB END WALL UPRIGHT
TAB END WALL / HEADER TO JAMB
G0000450 GIRT 5" X 24'-0"2
J0000100 SLIDING DOOR JAMB 10'-0"2
J0000110 SLIDING DOOR JAMB 12'-0"2
2 7/8 COLUMN - (END WALL WITH DOOR PARTS LIST)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIGURE 25 - (COVERING TRIM INSTALLATION)
COVERING TRIM INSTALLATION
1. SECURE THE TUBE LOCK AND 2X LUMBER TO THE COLUMN CONNECTION WITH VICE GRIPS. MAKE
SURE THAT THEY ARE PLUMB AND LEVEL. DRILL A 5/16" HOLE THROUGH THE TUBE LOCK AND
2X LUMBER.
2. BOLT THE TUBE LOCK AND 2X LUMBER TO THE COLUMN CONNECTION WITH A 1/4" X 2" CARRIAGE
BOLT.
1 5/8 COLUMN
2 7/8 COLUMN
STEEL GIRT OPTION FOR ANY SIZE COLUMN
AutoCAD SHX Text
TUBE LOCK II OPTION I SPLICE BOW OPTION II END COMBO OPTION III
AutoCAD SHX Text
TUBE LOCK II OPTION I
AutoCAD SHX Text
(2) 1/4" X 3/4" MACHINE BOLT #B9970030 WITH (2) 1/4" HEX NUT
AutoCAD SHX Text
ARCH
AutoCAD SHX Text
COLUMN TO HAND #C0155450
AutoCAD SHX Text
TUBE LOCK II
AutoCAD SHX Text
1/4" X 2" CARRIAGE BOLT #B9971360 2X LUMBER NOT SUPPLIED
AutoCAD SHX Text
(2) 3/8" X 1" MB (2) 3/8" HEX NUT
AutoCAD SHX Text
1/4" X 2" CARRIAGE BOLT #B9971360
AutoCAD SHX Text
CONN. COLUMN TO ARCH #C0155501
AutoCAD SHX Text
(2) 3/8" HEX NUT #N9970300
AutoCAD SHX Text
COLUMN
AutoCAD SHX Text
5/16" X 1 3/4" MACHINE BOLT #B9970270
AutoCAD SHX Text
CLAMP TUBE #C0101700
AutoCAD SHX Text
CONNECTOR #C0155500
AutoCAD SHX Text
(2) 3/8" X 1" MACHINE BOLT #B9970440
AutoCAD SHX Text
TUBE LOCK II
AutoCAD SHX Text
TAB SIDE GIRT WOOD #T0030700
AutoCAD SHX Text
1/4" X 2" CARRIAGE BOLT #B9971360
AutoCAD SHX Text
CONN. COLUMN TO ARCH #C0155451
AutoCAD SHX Text
14-14 X 1" TEK SCREW #S9970052
AutoCAD SHX Text
TUBE LOCK BASE
AutoCAD SHX Text
10-16 X 3/4" TEK SCREW #S9970010
AutoCAD SHX Text
KOOL CEL GIRT #K0000788 OR SIMILAR
AutoCAD SHX Text
COLUMN
AutoCAD SHX Text
TUBE LOCK BASE
AutoCAD SHX Text
10-16 X 3/4" TEK SCREW #S9970010
METAL SIDE GIRT
1. OPTION 1 - TUBE LOCK II - INSTALL THE TUBE LOCK TO THE END ARCH WITH A 10-16 X 3/4" TEK SCREWS AT 16" ON CENTER TYPICAL. SEE THE MATERIALS LIST FOR TUBE LOCK PART NUMBER.
DETAIL 2
COVERING TRIM INSTALLATION OPTIONS
2. OPTION 2 - TUBE LOCK SPLICE- IF YOUR BUILDING IS LONGER THAN THE POLY SHEETS SUPPLIED, YOU WILL HAVE A SPLICE BOW. IT WILL BE PLACED ON THE ARCH JUST BEFORE THE POLY SHEETS END.
ATTACH IT TO THE ARCH WITH 10-16 X 3/4" TEK SCREW AT 16" ON CENTER SOME BUILDINGS WILL HAVE THE SPLICER BOW AT THE ENDWALLS OF THE BUILDING, FOR FASTENING THE ROOF POLY AND
ENDWALL POLY ON SEPARATE CHANNELS.
AutoCAD SHX Text
10-16 X 3/4" TEK SCREW #S9970010
AutoCAD SHX Text
TUBE LOCK II
AutoCAD SHX Text
ARCH
AutoCAD SHX Text
10-16 X 3/4" TEK SCREW #S9970010
AutoCAD SHX Text
ARCH
TUBE LOCK SPLICE BOW
1. OPTION 3 - ARCH END COMBO FOR A FIBERGLASS END WALL COVERING, USE AN ALUMINUM ARCH
END COMBO. ATTACH IT TO THE END WALL ARCH WITH 10-16 X 3/4" TEK SCREWS.
GABLE END BAR OPTION
DETAIL 3
ALUMINUM SPLICE GABLE END BAR
AutoCAD SHX Text
10-16 X 3/4" TEK SCREW #S9970010
AutoCAD SHX Text
CHORD ARCH
AutoCAD SHX Text
PURLIN
AutoCAD SHX Text
ALUMINUM ARCH END COMBO SEE MATERIAL SHIPPED LIST FOR PART NUMBER
AutoCAD SHX Text
END WALL GIRTS WOOD OR METAL
AutoCAD SHX Text
END WALL UPRIGHT
AutoCAD SHX Text
SPLICE GABLE END BAR #S0001100
AutoCAD SHX Text
SPLICE GABLE END BAR #S0001100
AutoCAD SHX Text
ALUMINUM ARCH END COMBO
(2) 10-16 X 3/4" TEK SCREW #S9970010
DETAIL 2 (WOOD SIDEWALL GIRT OPTION SHOWN)
GABLE END BAR OPTION
W O
O D
O
P T
I O
N
STEEL
AutoCAD SHX Text
5" END WALL STEEL GIRT
AutoCAD SHX Text
14-14 X 1" TEK SCREW #S9970052
AutoCAD SHX Text
TAB #T0030880
AutoCAD SHX Text
WOOD BY OTHERS BY OTHERS
AutoCAD SHX Text
ALUM COMBO STRAIGHT #A0000252 #A0000254
AutoCAD SHX Text
ALUM ARCH COMBO END #A2400000 OR #A1150000
AutoCAD SHX Text
ALUM ARCH COMBO END #A2400000 OR #A1150000
AutoCAD SHX Text ALUM COMBO STRAIGHT #A0000252 or #A0000254
AutoCAD SHX Text ALUM COMBO STRAIGHT #A0000252 or #A0000254
AutoCAD SHX Text
(2) 1/4" X 2" CARRIAGE BOLT (WOOD OPTION ONLY)
AutoCAD SHX Text CLAMP TUBE (WOOD OPTION ONLY) #C0101390 AT 1-5/8" COLUMN ONLY SEE SHT 18 FOR 2-7/8" COLUMN
AutoCAD SHX Text
1/4" HEX NUT (WOOD OPTION ONLY)
AutoCAD SHX Text
SPLICE GABLE END BAR #S0001100
AutoCAD SHX Text
%%UALUMINUM SPLICE GABLE END BAR
AutoCAD SHX Text
ALUM ARCH COMBO END
AutoCAD SHX Text
ALUM ARCH COMBO END #A0000210
AutoCAD SHX Text
(2) 10-16 X 3/4" TEK SCREW
#10 X 3/4" TEK SCREW AT GIRT LOCATIONS
INSTALLATION OF POLY COVERING
WITH TUBE LOCK
1. APPLY THE POLY FILM (ONE OR MORE LAYERS) OVER THE PREVIOUSLY INSTALLED TUBE LOCK.
2. INSERT THE LONG LEG OF THE CAP FIRST. KEEP IT NEXT TO THE INFLATED SIDE OF THE COVERING.
3. TEK SCREW THE TUBE LOCK CAP TO THE BASE OR ARCH END COMBO WITH A 10-16 X 3/4" TEK SCREWS AT EACH END. TO INSTALL STRAIGHT 6' TUBE LOCK CAPS ON ARCHED SEGMENTS, FIRST SCREW IN ONE END AND WITH THE USE OF A MALLET, WORK YOUR WAY AROUND THE ARCH TO ACHIEVE
THE REQUIRED CURVATURE.
DETAIL 2
DETAIL 3
AutoCAD SHX Text
POLY
POLY
FIGURE 26 - (POLY INSTALLATION)
INSTALLATION OF POLY COVERING
ON ARCHED BUILDINGS
1. ON SINGLE BUILDINGS, ROLL OUT THE POLY LENGTHWISE NEXT TO BUILDING.
2. WAD UP THE POLY (APPROX. EVERY 20') AND TIE IT WITH ROPES ON THE SIDE OF THE POLY FURTHEST
FROM THE BUILDING.
3. THROW ROPES OVER THE BUILDING AND PULL THE POLY ONTO THE BUILDING. REPEAT THIS
PROCEDURE FOR MULTIPLE LAYERS OF POLY.
4. INSTALLING POLY REQUIRES A MINIMUM OF FOUR PEOPLE, TWO PEOPLE TO HOLD THE POLY IN PLACE AT THE END OF THE BUILDING, ONE ON EACH SIDE. THE OTHER TWO PEOPLE STARTING AT THE OPPOSITE END OF BUILDING TO INSTALL THE TUBE LOCK CAP SIMULTANEOUSLY, ON EACH SIDE OF
BUILDING. (SEE PAGE 27 FOR POLY LOCKING INSTRUCTIONS).
5. SECURE THE TUBE LOCK CAP WITH TEK SCREWS AT EACH END.
INSTALLATION OF INFLATOR FAN
(OPTIONAL)
1. ATTACH THE INFLATOR FAN HANGER TO THE GUTTER WITH (2) 5/16" X 3/4" MACHINE BOLTS WITH
WASHERS AND (2) 5/16" HEX NUTS.
CAUTION - BE SURE THERE ARE NO UNDERGROUND OR OVERHEAD ELECTRICAL WIRES, WATER
PIPES, GAS LINES, ETC. ON OR NEAR THE JOB SITE.
2. CLAMP THE INFLATOR FAN HOSE TO THE INFLATOR FAN (CLAMPS SUPPLIED WITH FAN).
3. ATTACH THE MOUNTING PLATE WITH THE FAN TO THE INFLATOR FAN HANGER WITH (2) 1/4" X 3/4"
MACHINE BOLTS AND (2) 1/4" HEX NUTS.
4. TO CUT THE POLY, PUT YOUR HAND BETWEEN THE 2 LAYERS OF POLY AND CUT A 3" "X" SLIGHTLY SMALLER THAN THE SMALL END OF THE INFLATOR COUPLING IN THE BOTTOM LAYER OF THE POLY, ABOVE THE INFLATOR FAN.
5. SLIP ONE RUBBER WASHER OVER THE INFLATOR COUPLING. SLIDE THE COUPLING BETWEEN THE TWO
LAYERS OF POLY AND PUSH THE SMALL END THROUGH THE HOLE MADE IN STEP 2.
6. SLIP THE SECOND RUBBER WASHER OVER THE SMALL END OF THE COUPLING AND SCREW ON THE
NUT, SANDWICHING THE BOTTOM LAYER OF POLY BETWEEN THE TWO RUBBER WASHERS.
7. CLAMP THE INFLATOR HOSE TO THE INFLATOR COUPLING.
8. SECURE THE POLY WITH THE TUBE LOCK. (SEE PAGE 28).
9. WIRE THE INFLATOR FAN TO 110 VOLT ELECTRICAL OUTLET.
10. CLAMP THE INTAKE TO THE INFLATOR FAN.
11. CUT A HOLE IN THE SIDE WALL COVERINGS SO THE EXTERIOR VENT CAN SLIDE
THROUGH.
12. SLIDE THE VENT THROUGH THE SIDE WALL AND CLAMP THE INTAKE HOSE TO IT.
(BE CAREFUL TO KEEP THE CIRCLE CONTINUOS SO THAT
WHEN POLY IS INFLATED THE WALL WILL NOT RIP.)
(FOR DOUBLE POLY COVERING OPTION)
INFLATOR FAN ASSEMBLY
FIGURE 1
FIGURE 31 - (INFLATOR FAN ASSEMBLY)
(FOR DOUBLE POLY COVERING OPTION)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1. APPLY POLY FILM (ONE OR MORE LAYERS) OVER PREVIOUSLY INSTALLED VINNIPET BASE.
2. INSERT ONE EDGE OF THE VINNIPET SPRING INTO THE VINNIPET BASE. KEEPING POLY TIGHT WEAVE
THE VINNIPET SPRING INTO THE BASE SECURING THE POLY.
3. INSERT ONE EDGE OF THE SECOND VINNIPET SPRING INTO THE VINNIPET BASE. KEEPING POLY TIGHT
WEAVE THE SECOND VINNIPET SPRING INTO THE BASE SECURING THE POLY.
WARRANTY CONLEY'S MFG. AND SALES, THEIR EMPLOYEES OR REPRESENTATIVES, WILL NOT BE RESPONSIBLE FOR ANY DAMAGE TO GREENHOUSE COVERING, STRUCTURES, CROPS OR EQUIPMENT WHEN USED IN CONJUNCTION WITH OUR TUBE - LOCK, OR ANY OTHER LOCKING DEVICE MFG,D BY
C.M.S. OR OTHERS.
INSTALLATION OF POLY COVERING
WITH VINNIPET SPRING
AutoCAD SHX Text
POLY
AutoCAD SHX Text
POLY
AutoCAD SHX Text
%%UNOTE: TEK SCREW ALL VINNIPET BASE AT A MINIMUM OF 16" ON CENTER
USE DOUBLE CLIPS WHEN INSTALLING 32' OR WIDER POLY, DOUBLE POLY, AND/OR BUILDING IS LOCATED IN HIGH WIND AREA.