Attachment III - Drawings.pdf
PDF 8 MB Posted
- Attached to
- Z2DA--Project No. 539-CSI-207 - Prepare Site for MRI. Federal contract opportunity
- Solicitation number
- 36C25024B0100
About this file
This document appears to be a set of drawings and specifications for a renovation project at a Department of Veterans Affairs (VA) medical center in Cincinnati, Ohio. The project involves the preparation of a site to install a new Magnetic Resonance Imaging (MRI) system.
The key details include:
- Project Number: 539-CSI-207
- Project Title: VA Cincinnati MRI Site Prep
- Location: 3200 Vine Street, Cincinnati, OH 45220
- Scope: Renovation of approximately 930 square feet on the second and third floors to accommodate the new MRI system, including a control room, MRI scanning room, and support spaces.
- Architectural, mechanical, and electrical drawings are provided.
- The project is fully sprinklered and complies with NFPA 101 Life Safety Code and other applicable codes and standards.
- The solicitation number is 36C25024B0100, and the federal agency is the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 10.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25024B0100 0005.docx | DOCX document | |
| Addendum 1.pdf | ||
| 36C25024B0100 0004.docx | DOCX document | |
| 36C25024B0100 0003.docx | DOCX document | |
| 36C25024B0100 0002.docx | DOCX document | |
| 36C25024B0100 0001.docx | DOCX document | |
| Attachment V- RFI Form.pdf | ||
| Attachment II - Specs.pdf | ||
| Attachment I - DBA WD.pdf | ||
| 36C25024B0100_1.docx | DOCX document | |
| Attachment IV - EMR Form.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
UPUP
UP
UP EXTERIOR ELEVATION
INTERIOR ELEVATION
SECTION/DETAIL NUMBER
DRAWING NUMBER
EQUIPMENT TAG
COLUMN GRID
NOTE
WINDOW OPENING
DOOR OPENING
ROOM NAME
ROOM NUMBER
WALL TYPE
CEILING HEIGHT
FINISH DESIGNATION
X
10'-8"
X
X
XX.X-X
XX
X
1/A101
X
A101
XX
TOILET ACCESSORY TAGX SIGNAGE TAG
A101
SIM
X
AREA OF WORK
SECOND FLOOR
RM# A2001, A2001A, A2007
Ludlow Ave.
C lif to n A v e
CINCINNATI
STATE
TECH.
Hopple St.
M.L.K. Dr.
McMillan St.
UNIV. OF
CINCINNATI
W.H.T Rd.
VAMC
3200 VINE ST.
M.L.K. Dr.
V in e
S t.
ZOO
Jefferson A ve.
UNIV.
HOSPITAL
Mitchell Ave.
R ea di ng
R d.
V ic to ry
P kw
y. XAVIER
UNIV.
AREA OF WORK
THIRD FLOOR ROOF
JASON
H.
ROSS
2118221
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
VA Project No.
RDC/JPA Project No.
Department of Veterans Affairs Medical Center
HEAPY ENGINEERING
MECHANICAL ELECTRICAL COMMISSIONING TECHNOLOGY
1400 WEST DOROTHY LANE
DAYTON, OH 45409
937.224.0861 P
ARCHITECTURE PLANNING INTERIOR DESIGN
524 FERNWOOD AVENUE
ALTAMONTE SPRINGS, FLORIDA 32701
407.830.6522 P
RDC / JOHN POE ARCHITECTS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
TERRACON CONSULTING, INC.
ENVIRONMENTAL
611 LUNKEN PARK DRIVE
CINCINNATI, OH 45226
513.321.5816 P
/1
/2
:0
:5
P
M
VA Cincinnati MRI Site Prep
05/30/2023
COVER SHEET
G001
JWDF
539-CSI-207
Cincinnati, OH
VA Cincinnati MRI Site Prep
3200 Vine Street Cincinnati, OH 45220 PROJECT #: 539-CSI-207
Bid Documents 22006.00
G001 COVER SHEET
G100 CODE DATA
A101 NEW WORK PLAN SECOND FLOOR
A102 NEW WORK PLAN THIRD FLOOR
A401 INTERIOR ELEVATIONS AND DETAILS
AF101 FINISH PLANS AND DETAILS
M001 ABBREVIATIONS, LEGEND & DRAWING INDEX
M101 PARTIAL SECOND FLOOR PLAN - REMOVALS AND NEW WORK
M102 PARTIAL THIRD FLOOR PLAN - REMOVALS AND NEW WORK
E001 ABBREVIATIONS, LEGEND & DRAWING INDEX
E100 ELECTRICAL PARTIAL FLOOR PLANS
GENERAL CONSTRUCTION NOTES
7. CONTRACTOR IS RESPONSIBLE TO VERIFY SIZES OF ALL EQUIPMENT, ETC. TO
BE INSTALLED AS PART OF THIS PROJECT, AND WHERE NECESSARY, MAKE
SPECIAL PROVISIONS TO INSTALL EQUIPMENT THAT IS TOO LARGE TO FIT
THROUGH FINISHED OPENINGS.
8. CONTRACTOR SHALL PROVIDE WOOD BLOCKING AT TOILET ACCESSORIES,
HAND RAILS, BUMPER RAILS, SHELVING, CASEWORK, MOUNTING BRACKETS
AND OTHER WALL MOUNTED ITEMS, AS INDICATED IN THE CONTRACT
DOCUMENTS AND AS RECOMMENDED BY PRODUCT MANUFACTURERS. ALL
WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED.
9. ALL EXPOSED NEW WORK IS TO RECEIVE NEW FINISHES UNLESS
SPECIFICALLY NOTED OTHERWISE. iF NO FINISH IS INDICATED AT A
PARTICULAR SURFACE, CONTRACTOR SHALL PROVIDE FINISH(S) AS
INDICATED AT SIMILAR CONDITIONS.
10. CONTRACTOR SHALL PROVIDE COMPLETE AND FULLY OPERATIONAL
SYSTEMS WHICH COMPLY WITH STATED CODES AND REGULATIONS. WHERE
THE OMISSION OF A PART OR ELEMENT OF A SYSTEM WOULD RESULT IN THE
NON-OPERATION, OR INCORRECT OPERATION OF A SYSTEM, CONTRACTOR
SHALL INCLUDE SAID PART OR ELEMENT AS PART OF THE WORK.
11. ALL PENETRATIONS THROUGH NEW AND/OR EXISTING SMOKE OR FIRE RATED
WALLS SHALL BE SMOKE/FIRE STOPPED AS REQUIRED BY THE RATING OF
THE WALL.
12. FIRE PROTECTION CONTRACTOR'S SPRINKLER DESIGN WILL BE SUBJECT TO
AN INDEPENDENT REVIEW BY A CERTIFIED FIRE PROTECTION ENGINEER
RETAINED BY THE OWNER. THE FIRE PROTECTION CONTRACTOR IS
RESPONSIBLE FOR MAKING ANY REQUIRED CHANGES TO THE DESIGN AS
IDENTIFIED BY THE OWNER'S FIRE PROTECTION ENGINEER AS NECESSARY
FOR COMPLIANCE WITH SPECIFIED NFPA REQUIREMENTS.
* PLEASE NOTE THAT THE TERM PROJECT ENGINEER REFERS TO THE
CONTRACTING OFFICER'S REPRESENTATIVE (C.O.R.).
1. ALL WORK SHALL COMPLY WITH THE LATEST NFPA 101 LIFE SAFETY CODE,
INTERNATIONAL BUILDING CODE, AND OTHER COES AS IDENTIFIED IN VHA
PROGRAM GUIDE PG-18-3, TOPIC 01, CODES, STANDARDS AND EXECUTIVE
ORDERS WHICH CAN BE FOUND ON THE DEPARTMENT OF VETERAN AFFAIRS,
TECHNICAL INFORMATION LIBRRARY WEBSITE.
2. ALL WORK SHALL COMPLY WITH REQUIREMENTS OF THE LATEST
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARD (ABAAS) AND
DEPARTMENT OF VETERANS AFFAIRS BARRIER FREE DESIGN GUIDE PG-18-13
WHICH CAN BE FOUND ON THE DEPARTMENT OF VETERANS AFFAIRS
TECHNICAL INFORMATION LIBRARY WEBSITE.
3. CONTRACTOR IS RESPONSIBLE TO VISIT THE SITE, EXAMINE AND ACCEPT
EXISTING CONDITIONS PRIOR TO BIDDING. SITE VISITS TO BE COORDINATED
WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.
4. CONTRACTOR IS RESPONSIBLE TO REPAIR AND/OR REFINISH, TO MATCH
ADJACENT EXISTING SURFACES, ANY EXISTING MATERIALS TO REMAIN THAT
ARE DAMAGED DURING THE COURSE OF DEMOLITION OR NEW WORK.
5. WHERE REMOVAL OF EXISTING WORK IS REQUIRED FOR INSTALLATION OF
NEW WORK, CONTRACTOR SHALL REPAIR EXISTING CONSTRUCTION TO
REMAIN OR PROVIDE NEW CONSTRUCTION TO MATCH EXISTING ADJACENT
SURFACES TO REMAIN.
6. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL CONDITIONS AND
DIMENSIONS PRIOR TO ORDERING, FABRICATING OR INSTALLING NEW
MATERIALS.
DRAWING INDEX
N.T.S.Scale:
KEY PLAN - SECOND FLOOR
N.T.S.Scale:
VICINITY MAP
N
N
N.T.S.Scale:
KEYPLAN - THIRD FLOORN
Revisions Date
0-HR Smoke Partition - [OBC 710] / NFPA 101-8.4
1-HR Smoke Barrier - [OBC 709] / NFPA 101-8.5
1-HR Fire Barrier - [OBC 706] / NFPA 101-8.3
2-HR Fire Barrier - [OBC 706] / NFPA 101-8.3
Means of Egress
Existing Wall to Remain
New Wall
CODE LEGEND
MRI ROOM
A2001A
CONTROL
ROOM
A2001
MRI
SCANNING RM
A2023
SYSTEM
COMPONENT
RM
A2001B
MRI
COMPONENT
A2007
CORRIDOR
C-2-11
CORRIDOR
C-2-11
EMS
A2025
Area of Renovation - 930 sf
Smoke Compartment - 8,680 sf
Travel Distance to Exit:
Max. Allowable = 200' per 19.2.5.7.3.3 (B,2) Actual = 151'
Travel Distance to Exit Access Corridor Max. Allowable = 100' per 19.2.5.7.3.3 (A) Actual = 86'
Access to Exit Stair
JASON
H.
ROSS
2118221
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
/1
/2
:0
:5
P
M
VA Cincinnati MRI Site Prep
05/30/2023
CODE DATA
G100
JWDF
539-CSI-207
Cincinnati, OH
Bid Documents 22006.00
N.T.S.Scale:
LIFE SAFETY PLAN - PARTIAL SECOND FLOOR
Code: NFPA 101 Life Safety Code (2021 Edition)
Construction Type: Type I (222)
Occupancy: Health Care Occupancy
Height: Partial 1 story renovation to existing 4 story building
Area of Work: 930 SF - MRI Room, Control Room, MRI Component Room
Protection: Fully Suppressed
Chapter 4 - General
• 4.4.2.2 -Prescriptive-based life safety design meeting the requirements of Chapters 1 thru 3, Sections 4.5 thru 4.8, and
Chapters 6 thru 43 of this Code shall be deemed to satisfy the provisions of Sections 4.1 and 4.2.
• 4.4.2.3 -Where req’ts in Chapters 11 thru 43 differ from req’ts in Chapters 1 thru 4 and 6 thru 10, the req’ts of Chapters 11 thru
43 shall govern.
• 4.6.1.1 -The authority having jurisdiction (AHJ) shall determine whether the provisions of this Code are met.
• 4.6.7.1 -Rehabilitation category per 43.2.2.1.2 Renovation.
Chapter - 6 Classification of Occupancy and Hazard of Content
• 6.1.5 - Health Care Occupancy
• 6.2.2.1 -Hazard classification = Ordinary
Chapter 7 - Means of Egress
• 7.1.3.1 - Exit Access Corridors: 1/2 hr. fire rating is required for corridor walls per 19.3.6.2.2 (NO CHANGE)
• 7.3.1.2 – Occupant Load:
Second Floor (Renovation):
HC - Inpatient treatment Dept: 760 sf @ 240 sf/occ = 4 occup (NO CHANGE in area or occupant load) Storage: 170 sf @ 300 sf/occ = 1 occup (NO CHANGE in area or occupant load) Total: 930 sf
• 7.3.2.2 – Max. projection within means of egress on ea. side: 4-1/2” (38” hgt. max.).
• 7.3.3.1 – Egress capacity (Health Care, sprinklered): (NO CHANGE in occupant load & egress capacity)
Table 7.3.3.1- Stairs = .3” per occup; Level components and ramps = .2” per occup.
• 7.4.1.2 – Min. number of means of egress from any story = 2.
(1) Occupant load >500 and <1,000 = 3 exits minimum. (NO CHANGE)
Chapter 8 - Features of Fire Protection:
• Table 8.3.3.2.2 – Min Fire Protection for Openings in Fire-rated Assemblies:
Component Walls Fire Drs Vision Panel (size) FR Vision Panel FR Window Vert. shafts 2 hr 1-1/2 hr Max tested D-H-90 NP (stairs, exits):
Fire Barriers: 2 hr 1-1/2 hr Max tested D-H-90 NP
1 hr 3/4 hr Max tested D-H-45 3/4 hr Smoke Barriers: 1 hr 1/3 hr Max tested D-20 3/4 hr
1/2 hr 1/3 hr Max tested D-20 1/3 hr Smoke Part'ns: 1 hr 1/3 hr Max tested D-20 3/4 hr
1/2 hr 1/3 hr Max tested D-20 1/3 hr
• 8.3.4.2.1 – Firestop Systems – Penetrations that pass thru a fire barrier shall be protected by a firestop system or device.
• 8.3.4.2.2 – The firestop system or device shall be tested in accordance with ASTM E814 or UL 1479.
• 8.3.4.8 – Openings thru fire barriers for air-handling ductwork or air movement shall be protected per 9.2.1.
• 8.4.1 - Smoke Partitions shall limit the transfer of smoke.
• 8.5.1 - Smoke Barriers shall restrict the transfer of smoke and have 1/2 hour fire resistance rating per 19.3.7.3 (1 hour provided).
• 8.5.3 - Fire Barriers that meet requirements of Section 8.5 shall be permitted to be used as a smoke barrier.
Chapter 9 - Building Service and Fire Protection Equipment
• 9.6.1.3 – Fire Alarm System req’d for life safety shall be per NFPA 70 (2020) and 72 (2019).
• 9.6.3.1 – Occupant notification shall be provided per 9.6.3 and 19.3.4.3.1.
• 9.6.3.5 – Where permitted by Chapters 11 thru 43, a positive alarm sequence shall be permitted per NFPA 72 (2019) (See 19.3.4.3).
• 9.6.4.1 – Emergency Forces notification req’d per 9.6.4 and 19.3.4.3.2.1.
• 9.6.5.1 – Emergency Control functions shall be installed per NFPA 72 (2019) as req’d per 9.6.5 and 19.3.4.4.
• 9.6.8.1 – Alarm annunciation is required per 9.6.8.
• 9.7.1.1 – Supervised automatic sprinkler system as req’d by 9.7.1 and 19.3.5.3 and shall comply with NFPA 13 (2019).
• 9.9 - Portable fire extinguishers shall be selected, installed, inspected, and maintained per NFPA 10 (2018).
Chapter 10 – Interior Finish, Contents, and Furnishings
• 10.2.2- Interior Finish Classification Limitations
Table A.10.2.2 - Interior Finish Classification Limitations: Health Care (Existing) Exit Access Corridors: Class A or B.
Other Spaces: Class A or B.
• 10.2.3.1.1 - Interior wall and ceiling finish materials shall be classified in accordance with NFPA 286 and comply with 10.2.3.2.
• 10.2.3.1.2 - Materials tested in accordance with 10.2.3.1.1 and complying with 10.2.3.2 shall also be considered to comply with the requirements of Class A in accordance with 10.2.3.3.
• 10.2.3.3 – Wall and Ceiling – Classifications characteristics:
(1) Class A: Flame spread: 0-25; Smoke dev.: 0-450.
(2) Class B: Flame spread: 26-75; Smoke dev.: 0-450.
(3) Class C: Flame spread: 76-200; Smoke dev.: 0-450.
• 10.2.3.3.1 – Existing interior finish exempt from smoke dev. criteria.
• 10.2.7.2 – Floor finish other than carpet: Min. Rad flux: .1 W/ cm².
• 10.2.8.1 – Wall and Ceiling finishes, where sprinkled:
Class C permitted in any location where Class B is req’d.
Class B permitted in any location where Class A is req’d.
• 10.2.8.2 – Floor finishes, where sprinkled:
Class II permitted in any location where Class I is req’d.
Provisions of 10.2.7.2 shall apply where Class II is req’d.
Chapter 19 - Existing Health Care Occupancies
• 19.1.1.1.4 - The area of work is an existing hospital and therefore falls under Chapter 19.
• 19.1.6.1 - Construction Type Limitations (Table 19.1.6.1): Type II (222), sprinklered, no story limitations.
• 19.1.7 - Occupant Load per Table 7.3.1.2. (NO CHANGE)
• 19.2.3.4 - Existing corridors required for exit access in hospitals shall be not less than 4 feet in clear width serving patient sleeping rooms. Actual: 8-0" (NO CHANGE).
• 19.2.5.3 - Dead end corridors shall not exceed 30’.
• 19.2.5.4 - Every corridor shall have access to not less than two approved exits without passing through any intervening spaces other than corridors or lobbies.
• 19.2.5.6.4 - Rooms within suites per 19.2.5.7 shall not be required to have an exit access door leading directly to an exit access corridor.
• 19.2.5.7.1.2 - Suite Separation – Suites shall be separated from remainder of the building by walls and doors (0-hr smoke partitions).
• 19.2.5.7.3.3 - Patient Care Non-Sleeping Suite Travel Distance
(A) Travel distance between any point in patient care non-sleeping suite and an exit access corridor: 100' (NO CHANGE)
(B) Travel distance between any point in non-sleeping suite and an exit: 200' (w/ sprinkler system). (NO CHANGE)
• 19.3.4.1 - Health care occupancies shall be provided with a fire alarm system per Section 9.6.
• 19.3.5.3 - Building containing hospitals shall be protected throughout by approved, supervised automatic sprinkler systems per
Section 9.7.
• 19.3.5.12 - Portable fire extinguishers shall be provided in all health care occupancies per Section 9.9.
• 19.3.6.2.2 - Corridor walls shall have min. 1/2 hour fire resistance rating. (NO CHANGE)
• 19.3.6.2.3 - Corridor walls shall form a barrier to limit the transfer of smoke but are not required to be smoke barriers or smoke partitions.
• 19.3.6.3.1 - Corridor doors shall be doors constructed to resist the passage of smoke.
Chapter 43 - Building Rehabilitation
• 43.1.2.1 - Any building undergoing repair, renovation, modification, or reconstruction shall comply with both of the following:
(1) Req'ts of the applicable existing occupancy chapters (Chapter 19).
(2) Req'ts of the applicable secton of this Chapter (Sections 43.4).
• 43.4.1.3 - Renovations, General Req'ts: All new work shall comply with the req'ts of other sections of this Code applicable to existing construction.
N
S
S
MRI ROOM
A2001A
CONTROL
ROOM
A2001
MRI
SCANNING RM
A2023
SYSTEM
COMPONENT
RM
A2001B
MRI
COMPONENT
A2007
CORRIDOR
C-2-11
CORRIDOR
C-2-11
CORRIDOR
C-2-11
EMS
A2025
SPECIAL
PROCEDURES
A2015
AVAIL.
A2021
S.P. CONTROL
A2009
A
2.092.09
2.192.19
2.09
2.012.012.012.01
2.10
2.09
2.09
A401
A
A401
2.562.56
2.04
2.09
2.012.012.012.01
CONTROL
ROOM
A2001
MRI ROOM
A2001A
MRI
COMPONENT
A2007
SPECIAL
PROCEDURES
A2015
MRI
SCANNING RM
A2023
SYSTEM
COMPONENT
RM
A2001B
EMS
A2025
S.P. CONTROL
A2009
AVAIL.
A2021
CORRIDOR
C-2-11
CORRIDOR
C-2-11
CORRIDOR
C-2-11
CHASE
2.05
2.062.06
2.022.02
2.022.022.022.02
REFLECTED CEILING PLAN LEGEND
Recessed downlight fixture
Supply Air Diffuser
Return Air Grille
2' x 4' light fixture
2' x 2' acoustical ceiling tile
Gypsum board / portland cement plaster ceiling / soffit - painted
Sprinkler head
SpeakerS
2' x 2' light fixture
AREA OF WORK
SECOND FLOOR
RM# A2001, A2001A, A2007
N
DEMOLITION LEGEND
Wall to be Demolished
Existing Wall to Remain
Area out of scope.
JASON
H.
ROSS
2118221
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
/3
/2
:0
:2
A
M
VA Cincinnati MRI Site Prep
05/30/2023
NEW WORK PLAN SECOND FLOOR
A101
JWDF
539-CSI-207
Cincinnati, OH
Bid Documents 22006.00
A. Verify all conditions in the field prior to fabrication, erection, and construction.
B. Protect existing structure as required during all phases of construction.
C. Coordinate contractor access to all phases of construction, deliveries, and debris removal with the C.O.R. See General Requirements.
D. Maximum time limit of 2 days from when existing chiller unit is taken offline and the new chiller unit is operational. Contractor to coordinate and schedule roof top equipment work accordingly to meet time constraint.
E. Interior finish work to occur following MRI equipment upgrade while magnet is offline.
2.01 No floor or wall work this room.
2.02 No ceiling work this room.
2.04 Existing floor finish to remain. Protect in place during construction.
2.05 Existing gypsum board ceiling/soffit to remain. Protect in place and repair any damage during construction.
2.06 Existing suspended ceiling system, fixtures, and devices to remain.
2.09 Existing casework to remain. Protect in place during construction.
2.10 Existing plumbing fixture to remain.
2.19 Existing equipment to remain. Protect in place. Verify the boundaries of the equipment where it contacts the floor.
2.56 Remove existing sheet vinyl floor finish and rubber base. Prep floor to receive new finishes.
PLAN NOTES
GENERAL NOTES
Scale: 1/4" = 1'-0"1
NEW WORK PLAN - SECOND FLOOR
N
Scale: 1/4" = 1'-0"2
REFLECTED CEILING PLAN - SECOND FLOOR
N
A. Remove all existing partitions shown with dashed line. Repair wall and floor finishes to match adjacent surfaces at areas of removal or scheduled new surfaces as required.
B. See Plumbing, HVAC and Electrical Drawings for removal work associated with those trades.
C. Computer and communication cables and/or other wiring, piping, tubing, etc. serving other areas and functions located above ceiling or in walls of area to be remodeled shall be maintained during demolition/construction process. Coordinate any required changes to these systems with the C.O.R.
GENERAL DEMOLITION NOTES
KEY PLAN - SECOND FLOOR
UPUP
UP
UP
AREA OF WORK
STEP #1
2.22
2.23
2.21
2.19
2.19
2.19
2.19
2.19
1/2" / 12"
1/2" / 12"
/2
/4
" / 1
/4
" / 1
7.02
/2
2.142.14
N
2.19
2.19
2.19
2.19
2.19
2.23
AREA OF WORK
STEP #2
1/2" / 12"
1/2" / 12"
/2
/4
" / 1
/4
" / 1
/2
7.02
23.06
7.04
23.05
23.05
23.05
7.04
7.04
7.04
23.06
2.24
2.19
2.19
2.19
2.19
2.19
1/2" / 12"
1/2" / 12"
/2
/4
" / 1
/4
" / 1
/2
7.02
AREA OF WORK
STEP #3
DEMOLITION LEGEND
Wall to be Demolished
Existing Wall to Remain
Area out of scope.
JASON
H.
ROSS
2118221
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
/3
/2
:1
:4
A
M
VA Cincinnati MRI Site Prep
05/30/2023
NEW WORK PLAN THIRD FLOOR
A102
JWDF
539-CSI-207
Cincinnati, OH
Bid Documents 22006.00
Scale: 1/4" = 1'-0"1
PARTIAL THIRD FLOOR ROOF - STEP #1
N
2.14 Remove existing support curbs/rails.
2.19 Existing equipment to remain. Protect in place. Verify the boundaries of the equipment where it contacts the floor.
2.21 Remove and salvage existing precast paver ballast for
reinstallation.
2.22 Remove existing ballasted EPDM membrane and tapered
polyiso roof insulation to concrete deck below as required to install new equipment support curbs. See Mechanical Drawings.
2.23 Maintain existing operational chiller unit and support curbs until new chiller unit is installed. See Mechanical Drawings.
2.24 Remove existing chiller unit and support curbs.
7.02 Existing roof drains to remain.
7.04 Install and repair existing EPDM roofing and tapered insulation.
Align and maintain existing roof slopes. Reinstall salvaged precast paver ballast.
23.05 Install new equipment support curbs. See Mechanical
Drawings.
23.06 New chiller unit (Owner-provided, Contractor-installed). See Mechanical Drawings.
ROOF PLAN NOTES
KEY PLAN - THIRD FLOOR
Area of Work- Third Floor Roof
Scale: 1/4" = 1'-0"2
PARTIAL THIRD FLOOR ROOF - STEP #2
Scale: 1/4" = 1'-0"3
PARTIAL THIRD FLOOR ROOF - STEP #3
N
N
A. Verify all conditions in the field prior to fabrication, erection, and construction.
B. Protect existing structure as required during all phases of construction.
C. Coordinate contractor access to all phases of construction, deliveries, and debris removal with the C.O.R. See General Requirements.
D. Maximum time limit of 2 days from when existing chiller unit is taken offline and the new chiller unit is operational. Contractor to coordinate and schedule roof top equipment work accordingly to meet time constraint.
E. Interior finish work to occur following MRI equipment upgrade while magnet is offline.
GENERAL NOTES
Keynote
Material Finish
SYMBOL LEGEND
WSF-1
2.09
2.11
2.11
2.09 2.09
WSF-1
2.11
2.11P-2
WSF-1
2.09
2.09 2.112.11
WSF-1
JASON
H.
ROSS
2118221
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
/1
/2
:0
:3
P
M
VA Cincinnati MRI Site Prep
05/30/2023
INTERIOR ELEVATIONS AND
DETAILS
A401
JWDF
539-CSI-207
Cincinnati, OH
Bid Documents 22006.00
A. See sheet 2.A807/2.A808/2.A809 for Floor Finish Plan.
B. See sheet 2.A711/2.A712 for Casework Details.
C. See sheet 2.A801 for Room Finish Schedule.
D. See sheet 2.A801 for Finish Materials Legend.
E. Provide tile substrate as follows: All shower stalls, Bathing Suite #220 will receive Cementious backer units. All Bathrooms, Restrooms, HAC will receive Water-resistant gyp. board. Kitchen, fireplace surond will receive Gyp. board.
2.09 Existing casework to remain. Protect in place during
construction.
2.11 Existing wall and base cabinets to remain. Protect in place during construction.
ELEVATION NOTES
GENERAL INT. ELEVATION NOTES
Scale: 1/4" = 1'-0"1 A2001A - MRI Room South
Scale: 1/4" = 1'-0"2 A2001A - MRI Room West1
Scale: 1/4" = 1'-0"3 A2001A - MRI Room North
Scale: 1/4" = 1'-0"4 A2001A - MRI Room East
MRI ROOM
A2001A
CONTROL
ROOM
A2001
MRI
COMPONENT
A2007
MRI
SCANNING RM
A2023
SYSTEM
COMPONENT
RM
A2001B
P-2
2.012.012.012.01
2.01
MRI ROOM
A2001A
CONTROL
ROOM
A2001
MRI
COMPONENT
A2007
MRI
SCANNING RM
A2023
SYSTEM
COMPONENT
RM
A2001B
WSF-1
VCT-1
2.19
2.012.012.012.01
2.01
2.04
JASON
H.
ROSS
2118221
IO
HO
FOET
A T
S
R E G I S
E T
R
ED RA
C H
TI
E C T
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
/1
/2
:0
:3
P
M
VA Cincinnati MRI Site Prep
05/30/2023
FINISH PLANS AND DETAILS
AF101
BMDF
539-CSI-207
Cincinnati, OH
Bid Documents 22006.00
A. All walls to be painted P-1 unless noted otherwise.
2.01 No floor or wall work this room.
2.04 Existing floor finish to remain. Protect in place during construction.
2.19 Existing equipment to remain. Protect in place. Verify the boundaries of the equipment where it contacts the floor.
PLAN NOTES
GENERAL FINISH PLAN NOTES
Scale: 1/4" = 1'-0"2
WALL FINISH PLAN
Scale: 1/4" = 1'-0"1
FLOOR FINISH PLAN
FINISH LEGEND
FINISH CATEGORY CODE FINISH TYPE MANUFACTURER PRODUCT / COLOR COMMENTS
06 41 16 PLASTIC LAMINATE FACED ARCHITECTURAL CABINETS
06 41 16 PLASTIC LAMINATE FACED
ARCHITECTURAL CABINETS
PL-1 PLASTIC LAMINATE
(CASEWORK)
- EXISTING TO REMAIN
09 51 00 ACOUSTICAL CEILINGS
09 51 00 ACOUSTICAL CEILINGS ACT-1 EXISTING TO REMAIN
09 65 16 RESILIENT SHEET FLOORING
09 65 16 RESILIENT SHEET FLOORING WSF-1 WELDED SHEET FLOORING MANNINGTON BIOSPEC MD- Fawn 15419, 6" Integral Cove Base
09 65 19 VINYL COMPOSITION TILE
09 65 19 VINYL COMPOSITION TILE VCT-1 VINYL COMPOSITION TILE - EXISTING TO REMAIN
09 91 00 PAINTING
09 91 00 PAINTING P-1 PAINT (FIELD) BENJAMIN MOORE 981 WIND'S BREATH GLOSS LEVEL 4; SATIN
09 91 00 PAINTING P-2 PAINT (ACCENT) BENJAMIN MOORE CSP-685 STAINED GLASS GLOSS LEVEL 4; SATIN
12 36 61 SOLID SURFACE COUNTERTOPS
12 36 61 SOLID SURFACE COUNTERTOPS SS-1 SOLID SURFACE
(COUNTERTOPS)
- EXISTING TO REMAIN
NN
UPUP
UP
UP
Tectonic Copyright 2007
NOTE: ALL SYMBOLS AND ABBREVIATIONS
ARE SUBJECT TO MODIFICATIONS
ON OTHER DRAWINGS.
ALL SYMBOLS OR ABBREVIATIONS
MIGHT NOT NECESSARILY BE USED ON
THIS PROJECT.
ABBREVIATIONS
AC - AIR COMPRESSOR OR AIR CONDITIONER
ACCU - AIR COOLED CONDENSING UNIT
AD - ACCESS DOOR OR AREA DRAIN
ADJ - ADJUSTABLE
AFF - ABOVE FINISHED FLOOR
AFG - ABOVE FINISHED GRADE
AFMS - AIR FLOW MEASURING STATION
ALT - ALTERNATE
AP - ACCESS PANEL
APPROX - APPROXIMATE
ARCH - ARCHITECT OR ARCHITECTURAL
ASSY - ASSEMBLY
ATC - AUTOMATIC TEMPERATURE CONTROL
(SYNONYMOUS WITH BAS)
BAS - BUILDING AUTOMATION SYSTEM
BDD - BACK DRAFT DAMPER
BFP - BACKFLOW PREVENTER
BLDG - BUILDING
BOB - BOTTOM OF BEAM
BOD - BOTTOM OF DUCT
BOE - BOTTOM OF EQUIPMENT
BOF - BOTTOM OF FOOTING
BOG - BOTTOM OF GRILLE
BOP - BOTTOM OF PIPE
BOT - BOTTOM
BTU - BRITISH THERMAL UNIT
BTUH - BRITISH THERMAL UNIT PER HOUR
CBD - COUNTER BALANCED BACKDRAFT DAMPER
CFCI - CONTRACTOR FURNISHED CONTRACTOR
INSTALLED
CFM - CUBIC FEET PER MINUTE
CHS - CHILLED WATER SUPPLY
CHR - CHILLED WATER RETURN
CHGR - CHILLED WATER GLYCOL SOLUTION RETURN
CHGS - CHILLED WATER GLYCOL SOLUTION SUPPLY
CLG - CEILING
CMU - CONCRETE MASONRY UNIT
CO - CLEAN OUT
CO2 - CARBON DIOXIDE
CONN - CONNECT OR CONNECTION
CONTR - CONTRACTOR
CTR - CENTER
CU - COPPER
CW - COLD WATER
CWR - CONDENSER WATER RETURN
CWS - CONDENSER WATER SUPPLY
D - DRAIN LINE
DB - DRY BULB
DDC - DIRECT DIGITAL CONTROLS
DI - DEIONIZED WATER
DIA - DIAMETER
DIM - DIMENSION
DN - DOWN
DWG - DRAWING
EA - EACH OR EXHAUST AIR
EAT - ENTERING AIR TEMPERATURE
EC - ELECTRICAL CONTRACTOR (DIVISION 26)
EJ - EXPANSION JOINT
ELEC - ELECTRICAL
ELEV - ELEVATOR
EQUIP - EQUIPMENT
ET - EXPANSION TANK
ETR - EXISTING TO REMAIN
EQS - EQUIPMENT SUPPLIER
EWT - ENTERING WATER TEMPERATURE
EXH - EXHAUST
EXP - EXPANSION
EXT - EXTERIOR
EX - EXISTING
FD - FLOOR DRAIN
FF - FINISHED FLOOR ELEVATION
FLR - FLOOR
FOB - FLAT ON BOTTOM
FOF - FUEL OIL FLOW
FOG - FUEL OIL GAUGE
FOR - FUEL OIL RETURN
FOS - FUEL OIL SUPPLY
FOT - FLAT ON TOP
FPM - FEET PER MINUTE
FSC - FIRE SUPPRESSION CONTRACTOR (DIVISION 21)
FT - FEET
FTG - FOOTING
G - GAS OR NATURAL GAS
GA - GAUGE
GAL - GALLON
GALV - GALVANIZED
GC - GENERAL TRADES CONTRACTOR
GPM - GALLONS PER MINUTE
HB - HOSE BIBB
HC - HVAC CONTRACTOR (DIVISION 23)
HD - HUB DRAIN
HG - REFRIGERANT HOT GAS
HP - HORSEPOWER
HPC - HIGH PRESSURE CONDENSATE RETURN
HPS - HIGH PRESSURE STEAM SUPPLY
HR - HOUR
HT - HEAT TRACE
HTR - HEATER
HVAC - HEATING, VENTILATING, AND AIR CONDITIONING
HW - HOT WATER
HWR - HEATING HOT WATER RETURN
HWS - HEATING HOT WATER SUPPLY
ID - INSIDE DIAMETER
INV - INVERT ELEVATION
IN - INCHES
KEC - KITCHEN EQUIPMENT CONTRACTOR
L - LENGTH
LAT - LEAVING AIR TEMPERATURE
LAV - LAVATORY
LBS - POUNDS
LPC - LOW PRESSURE CONDENSATE RETURN
LPS - LOW PRESSURE STEAM SUPPLY
LWT - LEAVING WATER TEMPERATURE
MAX - MAXIMUM
MDD - MOTORIZED DAMPER
MEZZ - MEZZANINE
MFR - MANUFACTURER
MH - MANHOLE
MIN - MINIMUM OR MINUTE
MISC - MISCELLANEOUS
MTD - MOUNTED
MTG - MOUNTING
MPC - MEDIUM PRESSURE CONDENSATE
RETURN
MPS - MEDIUM PRESSURE STEAM SUPPLY
MU - WATER MAKE-UP
N/C - NORMALLY CLOSED
NIC - NOT IN CONTRACT
N/O - NORMALLY OPEN
NOM - NOMINAL
NPT - NATIONAL PIPE THREAD
NTS - NOT TO SCALE
OA - OUTDOOR AIR
OBD - OPPOSED BLADE DAMPER
OD - OUTSIDE DIAMETER
OFCI - OWNER FURNISHED CONTRACTOR
INSTALLED
OFOI - OWNER FURNISHED OWNER INSTALLED
P - PROPANE GAS
PC - PLUMBING CONTRACTOR (DIVISION 22)
OR PUMPED CONDENSATE RETURN
PLBG - PLUMBING
PRESS - PRESSURE
PRV - PRESSURE REGULATING VALVE
PSF - POUNDS PER SQUARE FOOT
PSI - POUNDS PER SQUARE INCH
PSIG - POUNDS PER SQUARE INCH GAUGE
RA - RETURN AIR
RAD - RADIUS
RCP - REFLECTED CEILING PLAN
RD - ROOF DRAIN
REC - RECESSED
REQD - REQUIRED
RI - ROUGH IN
RL - REFRIGERANT LIQUID
ROS - REVERSE OSMOSIS WATER SUPPLY
ROR - REVERSE OSMOSIS WATER RETURN
RPM - REVOLUTIONS PER MINUTE
RS - REFRIGERANT SUCTION
S - SPRINKLER (WET)
SA - SUPPLY AIR
SAN - SANITARY OR SANITARY DRAIN
SCH - SCHEDULE
SCW - SOFT COLD WATER
SHT - SHEET
SPEC - SPECIFICATIONS
SQ - SQUARE
SR - SUPPLY RISER
SRV - SAFETY RELIEF VALVE
SS - STAINLESS STEEL
STD - STANDARD
STM - STORM OR STORM DRAINAGE
STRUC - STRUCTURAL OR STRUCTURE
SUC - SITE UTILITY CONTRACTOR
TEMP - TEMPERATURE
TOB - TOP OF BEAM
TOD - TOP OF DUCT
TOE - TOP OF EQUIPMENT
TOF - TOP OF FOOTING
TOJ - TOP OF JOIST
TOP - TOP OF PIPE
TOS - TOP OF SLAB OR TOP OF STEEL
TYP - TYPICAL
UNO - UNLESS NOTED OTHERWISE
V - VENT
VAC - VACUUM
VEL - VELOCITY
VFD - VARIABLE FREQUENCY DRIVE
(ADJUSTABLE FREQUENCY
MOTOR CONTROLLER)
VIB - VALVE IN BOX
VOL - VOLUME
VTR - VENT THROUGH ROOF
VR - VENT RISER
W/ - WITH
W/O - WITHOUT
WB - WET BULB
WCO - WALL CLEANOUT
GENERAL FLOOR PLAN NOTES
PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWN UNLESS
NOTED OTHERWISE.
DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.
A1
EQUIPMENT, DEVICE, OR PLUMBING FIXTURE MARK. LETTER DESIGNATIONS
REFER TO SCHEDULES.
H1 H1OR EQUIPMENT REFERENCE. LETTER DESIGNATION VARIES. REFER TO
SCHEDULES.
H2
B
H2
RISER OR STACK NUMBER
DETAIL: B = DETAIL DESIGNATION
H2 = SHEET WHERE DETAIL IS LOCATED
SECTION: 1 = SECTION DESIGNATION
H2 = SHEET WHERE DETAIL IS LOCATED
A1 "UP TO" SYMBOL (ITEM ON FLOOR ABOVE)
APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO TOP OR BOTTOM OF
EQUIPMENT, UNLESS NOTED OTHERWISE
10"
ELEV: 8' - 0"ELEV: 8' - 0"
TOD: 8' - 10"
BOD: 7' - 2"
20x20
20x20
APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO TOP OR BOTTOM OF
DUCTWORK, UNLESS NOTED OTHERWISE
APPROXIMATE DIMENSION ABOVE FINISHED FLOOR TO CENTERLINE OF PIPE,
UNLESS NOTED OTHERWISE
DL-1
UC-X DOOR UNDERCUT. X = HEIGHT OF UNDERCUT IN INCHES; 0.75 INCH
UNDERCUT IF NO HEIGHT IS NOTED. COORDINATE WITH GC.
DOOR LOUVER. 1 = SQUARE FEET OF LOUVER.
CONNECT TO EXISTING
HVAC PIPING DESIGNATIONS
CHILLED WATER SUPPLY PIPECHS
CONDENSER WATER SUPPLY PIPECWS
CONDENSER WATER RETURN PIPECWR
DRAIN LINE. PITCH IN DIRECTION INDICATEDD
HEATING HOT WATER SUPPLY PIPEHWS
HEATING HOT WATER RETURN PIPEHWR
WATER MAKE-UP PIPEMU
VENT PIPEV
REFRIGERANT LIQUID LINERL
REFRIGERANT SUCTION LINERS
EXPANSION TANK PIPEET
REFRIGERANT HOT GAS LINEHG
LOW PRESSURE CONDENSATE RETURN PIPELPC
LOW PRESSURE STEAM SUPPLY PIPELPS
MEDIUM PRESSURE CONDENSATE RETURN PIPEMPC
MEDIUM PRESSURE STEAM SUPPLY PIPEMPS
PUMPED CONDENSATE RETURN PIPEPC
HIGH PRESSURE CONDENSATE RETURN PIPEHPC
HIGH PRESSURE STEAM SUPPLY PIPEHPS
STEAM SUPPLY PIPE - NUMBER INDICATES P.S.I.G.10
MISC SYMBOLS
DUCTWORK SYMBOLS
ROUND BRANCH DUCTWORKCONICAL
FITTING
ACOUSTIC
FITTING
ACOUSTIC
FITTING
ADAD
D
R R
D
RECTANGULAR BRANCH DUCTWORK
SQUARE TEE WITH TURNING VANES
NOTE: ALL SQUARE ELBOWS IN
RECTANGULAR AND ROUND / OVAL
DUCTWORK SHALL BE PROVIDED WITH
TURNING VANES. REFER TO
SPECIFICATIONS FOR ADDITIONAL DETAILS.
EXISTING DUCTWORK TO REMOVED
RETURN AIR, RELIEF AIR, OR TRANSFER AIR
DUCTWORK. (UP AND DOWN) RADIUSED
OR SQUARE WITH TURNING VANES.
SUPPLY AIR OR OUTDOOR AIR DUCTWORK.
(UP AND DOWN) RADIUSED OR SQUARE
WITH TURNING VANES.
EXHAUST AIR DUCTWORK. (UP AND DOWN)
RADIUSED OR SQUARE WITH TURNING
VANES.
RECTANGULAR AND ROUND / OVAL
DUCTWORK RISE / DROP WITH 90° RADIUSED
OR SQUARE ELBOWS AND TURNING VANES.
RADIUS ELBOW
90° SQUARE ELBOW (WITH TURNING VANES)
NOTE: ALL SQUARE ELBOWS IN
RECTANGULAR AND ROUND DUCTWORK
SHALL BE PROVIDED WITH TURNING VANES.
ACCESS DOOR OR PANEL
DUCTWORK RISE IN DIRECTION OF AIR
FLOW
DUCTWORK DROP IN DIRECTION OF AIR
FLOW
DUCTWORK WITH ACOUSTICAL LINER.
LISTED DUCT SIZES ARE INSIDE CLEAR
DIMENSIONS.
RECTANGULAR ROUND / OVAL
FLEXIBLE DUCTWORK
FLEXIBLE CONNECTION
DUCTWORK CONSTRUCTED OF SPECIAL
MATERIAL AS NOTED
DIRECTION OF PITCH
RECTANGULAR DUCTWORK DIMENSIONS
(W x H)26x20
ROUND DUCTWORK DIMENSIONS (DIA)26ø
OVAL DUCTWORK DIMENSIONS (W x H)26x20 OV
DUCTWORK DEVICE SYMBOLS
WALL OR DUCTWORK MOUNTED AIR DEVICE. SG1 = DESIGNATION (REFER
TO AIR DEVICE SCHEDULE). 20x12 = DUCT CONNECTION SIZE (IN INCHES).
300 = REQUIRED CFM. 9'-0" = MOUNTING HEIGHT FROM FLOOR TO BOTTOM
OF GRILLE.
A3 10ø
MANUAL BALANCING DAMPER WITH LOCKING DEVICE
BDD = BACK DRAFT DAMPER
CBD = COUNTER-BALANCED BACK DRAFT DAMPER
SD = SMOKE DAMPER
FS = COMBINATION FIRE - SMOKE DAMPER
MDD = MOTORIZED DAMPER
AFMS = AIR FLOW MEASURING STATION
DUCT MOUNTED SMOKE DETECTOR. COORDINATE LOCATION.
HUMIDITY SENSOR - DUCT MOUNTED
SG1
20x12
BOG: 9'-0"
XXX
A-D
XX
H
SD
SP
AIR DEVICE. A3 = DESIGNATION (REFER TO FLOOR PLANS AND AIR DEVICE
SCHEDULE FOR VARIOUS DESIGNATIONS).
10ø = NECK SIZE (IN INCHES). 300 = REQUIRED CFM. ALL AIR DEVICE
DISCHARGE 4-WAY UNLESS NOTED WITH FLOW ARROWS. AIR DEVICE
SHOWN IS 2-WAY SIDE THROW. METHOD OF IDENTIFICATION ALSO APPLIES
TO OTHER CEILING MOUNTED AIR DEVICES.
FIRE DAMPER
A = TYPE (REFER TO FLOOR PLANS FOR VARIOUS TYPES)
D OR S = DYNAMIC OR STATIC
STATIC PRESSURE SENSOR - DUCT MOUNTED
C
CARBON DIOXIDE SENSOR - DUCT MOUNTED
S
TEMPERATURE SENSOR - DUCT MOUNTED
CHECK VALVE
T
P
FOB
FOT
SHUTOFF VALVE (REFER TO SPECIFICATIONS FOR REQUIRED TYPE BASED ON
APPLICATIONS)
CONCENTRIC PIPE REDUCER
ECCENTRIC PIPE REDUCER
PRESSURE GAUGE
TEMPERATURE GAUGE OR THERMOMETER
VALVES AND FITTINGS
10"
TOE: 3' - 0"
BOE: 0' - 6"
CHILLED WATER GLYCOL SOLUTION RETURN PIPECHGR
CHILLED WATER GLYCOL SOLUTION SUPPLY PIPECHGS
CHILLED WATER RETURN PIPECHR
SQUARE THROAT / RADIUS HEEL
FITTINGS NOT ACCEPTABLE
PIPING SYMBOLS
DOUBLE LINE SINGLE LINE
BOTTOM CONNECTION (45°)
BRANCH TEE CONNECTION (NOTE:
BULLHEAD TEE'S ARE NOT PERMITTED)
DIRECTION OF PITCH
DROP
ELBOW DOWN
ELBOW UP
EXISTING PIPE TO BE REMOVED
EXISTING PIPE TO REMAIN
FLOW DIRECTION DESIGNATION
PUMP
RISE
TOP CONNECTION (45°)
TOP CONNECTION (90°)
BOTTOM CONNECTION (90°)
DD
RR
PIPE RISER
RADIUS'D BRANCH
RADIUS'D TEE
EXISTING DUCTWORK TO REMAIN
UNLESS NOTED OTHERWISE ON DRAWINGS,
15° MAX FOR DIVERGING, 30° MAX FOR
CONVERGING TRANSITION
EMERGENCY SHUTOFF STATION. 46" MOUNTING HEIGHT UNLESS NOTED OTHERWISE.
SPACE TEMPERATURE SENSOR / THERMOSTAT. WHEN WALL MOUNTED, MOUNTING
HEIGHT 46" TO MEET ADA REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH
COORDINATE WITH ARCHITECT.
T
DP
DIFFERENTIAL PRESSURE SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO
MEET ADA REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH
ARCHITECT.
H
HUMIDITY SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA
REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH ARCHITECT.
CARBON DIOXIDE SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA
REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH ARCHITECT.
C
CO
CARBON MONOXIDE SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEET
ADA REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH
ARCHITECT.
TEMPERATURE SENSOR. WHEN WALL MOUNTED, MOUNTING HEIGHT 46" TO MEET ADA
REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH
ARCHITECT.
S
S TEMPERATURE SENSOR MOUNTED IN CEILING PLENUM.
STATIC PRESSURE SENSOR.SP
DRAIN VALVE WITH HOSE END CONNECTION
EXPANSION JOINT
MANUAL AIR VENT
AUTOMATIC AIR VENT
PRESSURE REDUCING VALVE
QUICK OPENING MANUAL VALVE
VACUUM BREAKER
NEEDLE VALVE
PRESSURE AND TEMPERATURE TEST PLUG
VACUUM GAUGE WITH STOP
END CAP
GLOBE VALVE
SHUTOFF VALVE AND BOX
SHUTOFF VALVE ON RISER
A
M
M
N
V
VB
SOLENOID VALVE
S
SAFETY RELIEF VALVE. FOR HYDRONIC SYSTEMS PIPE DISCHARGE AIR GAPPED TO
FLOOR DRAIN UNLESS NOTED OTHERWISE. FOR STEAM SYSTEMS PIPE DISCHARGE
TO OUTDOORS.
WATER METERM
PRESSURE GAUGE WITH COCK AND SIPHON LOOP
BI-METALIC STEAM TRAP AND DRIP ASSEMBLY
THERMOSTATIC STEAM TRAP AND DRIP ASSEMBLY
BM
TD
IB
FT
TS
FLOW METER
F
UNION
CLEANOUT
STRAINER
M
MODULATING 2 PORT AUTOMATIC CONTROL VALVE
M
MODULATING 3 PORT AUTOMATIC CONTROL VALVE
M
COMBINATION SHUTOFF AND BALANCING VALVE (REFER TO SPECIFICATIONS FOR
REQUIRED TYPE BASED ON APPLICATIONS)
STRAINER WITH A BLOW DOWN VALVE AND HOSE CONNECTION
AUTOMATIC FLOW CONTROLLER WITH P/T PLUG IN AND OUT
2 PORT AUTOMATIC CONTROL VALVE, 2-POSITION UNLESS SPECIFIED OTHERWISE
3 PORT AUTOMATIC CONTROL VALVE, 2-POSITION UNLESS SPECIFIED OTHERWISE
AUTOMATIC PRESSURE INDEPENDENT CONTROL VALVE
THERMODYNAMIC STEAM TRAP AND DRIP ASSEMBLY
INVERTED BUCKET STEAM TRAP AND DRIP ASSEMBLY
FLOAT AND THERMOSTATIC STEAM TRAP AND DRIP ASSEMBLY
AREA OF WORK
THIRD FLOOR ROOF
AREA OF WORK
SECOND FLOOR
RM# A2001, A2001A, A2007
P: 937-224-0861 www.heapy.com
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
PROJECT NO.
STATE COA FIRM NO.
/2
/2
:3
:1
P
M
VA Cincinnati MRI Site Prep
05/30/2023
ABBREVIATIONS, LEGEND &
DRAWING INDEX
M001
MGNWJS
539-CSI-207
Cincinnati, OH
Bid Documents 22006.00
2022-05234
01528
DRAWING INDEX - MECHANICAL
SHEET NUMBER SHEET NAME
M001 ABBREVIATIONS, LEGEND & DRAWING INDEX
M101 PARTIAL SECOND FLOOR PLAN - REMOVALS AND NEW WORK
M102 PARTIAL THIRD FLOOR PLAN - REMOVALS AND NEW WORK
N.T.S.Scale:
KEY PLAN - THIRD FLOOR
N.T.S.Scale:
KEY PLAN - SECOND FLOOR
N
N
GENERAL NOTES
1. THESE NOTES APPLY EQUALLY TO THE FULL SET OF DOCUMENTS.
2. THE DRAWINGS AND SPECIFICATIONS SHALL BE CAREFULLY STUDIED DURING THE COURSE OF BIDDING AND CONSTRUCTION. ANY ERRORS, OMISSIONS OR DISCREPANCIES ENCOUNTERED SHALL BE REFERRED IMMEDIATELY TO THE ARCHITECT/ENGINEER FOR INTERPRETATION OR
CORRECTION, SO THAT MISUNDERSTANDINGS AT A LATER DATE MAY BE AVOIDED.
3. SITE VISIT(S) SHALL BE AS OUTLINED IN PROJECT SPECIFICATIONS.
4. INSULATE PIPING WHERE EXISTING INSULATION HAS BEEN DAMAGED AND/OR REMOVED IN THE PERFORMANCE OF WORK IN THIS PROJECT.
5. PROVIDE ALL ROOFING PENETRATION, REPAIR & REINFORCEMENT IN THE EXISTING BUILDING FOR WORK INDICATED. ENGAGE A ROOFING SUBCONTRACTOR TO PERFORM THE ROOFING WORK. THE EXISTING ROOFING MEMBRANE AND INSULATION SHALL BE CUT, REMOVED AND RESTORED AS REQUIRED TO ATTAIN A WATERTIGHT CONDITION. THE ROOFING SUB-CONTRACTOR SHALL BE A CERTIFIED INSTALLER FOR
SUCH INSTALLATION TO MAINTAIN THE EXISTING WARRANTY ON THE ROOF.
6. REFER TO ALL SPECIFICATION SECTIONS AND THESE DRAWINGS FOR DETAILS OF BUILDING CONSTRUCTION TO ENSURE SPACE AND SATISFACTORY ARRANGEMENT FOR WORK. THE VARIOUS DRAWINGS COMPRISING THE SET ARE INTERDEPENDENT AND MUST BE USED JOINTLY AT ALL TIMES. REFER TO THE GENERAL REQUIREMENTS OF THE CONTRACT. THE NOTES AND SYMBOLS INDICATED ON THE DRAWINGS ARE FOR THE GUIDANCE OF ALL TRADES INVOLVED IN THE PROJECT AND MUST BE FOLLOWED TO EXECUTE THE WORK AS INTENDED. IF DISCREPANCIES OCCUR, CONTACT THE CONTRACTING OFFICERS REPRESENTATIVE (COR) THRU THE CONTRACTING OFFICER
FOR CLARIFICATION BEFORE PROCEEDING.
7. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS ON THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. SEE SPECIFICATIONS FOR MORE
SPECIFIC DETAILS ON RESPONSIBILITIES.
8. ALL WORK MUST BE COORDINATED WITH THE CONTRACTING OFFICER AND COR TO MAINTAIN OPERATION OF THE EXISTING FACILITY.
9. COORDINATE ALL WORK WITH THE WORK OF OTHERS. KEEP INFORMED OF THE PROGRESS AND DETAIL DEVELOPMENT OF THE WORK OF OTHERS. COORDINATE AND EXPEDITE WORK WITH OTHERS SO THAT THE PROGRESS OF THE TOTAL WORK SHALL BE KEPT ON SCHEDULE.
10. ALL WORK SHALL BE PERFORMED IN COMPLETE COMPLIANCE WITH ALL GOVERNING CODES AND STANDARDS.
11. EXISTING CONDITIONS SHOWN HAVE BEEN BASED UPON VISUAL OBSERVATION AND/OR AVAILABLE DRAWING INFORMATION, AND MAY BE AT VARIANCE WITH ACTUAL WORK IN PLACE. THE CONTRACTOR SHALL TAKE ALL NECESSARY FIELD MEASUREMENTS AND FIELD VERIFY ALL CONDITIONS AFFECTING THE EXECUTION OF THE WORK. ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE WORK SHOWN ON THE CONTRACT DOCUMENTS WHICH MAY IMPACT THE PROGRESS OF THE WORK SHALL BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER IN WRITING FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK.
12. FITTING OR PLACING WORK INTO OR ON THE WORK OF OTHERS CONSTITUTES ACCEPTANCE OF THE SUITABILITY OF THE WORK IN PLACE. IF THE WORK OF OTHERS IS NOT ACCEPTABLE, NOTIFY THE CONTRACTING OFFICERS REPRESENTATIVE (COR) FOR THE WORK TO BE CORRECTED. ANY NEW WORK INSTALLED IN UNSUITABLE EXISTING CONDITIONS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR OR TRADE INSTALLING THE NEW WORK. NO CLAIMS FOR ADDITIONAL COMPENSATION FOR CORRECTING WORK INSTALLED IN UNSUITABLE
EXISTING CONDITIONS WILL BE CONSIDERED.
13. IF, IN THE PERFORMANCE OF THIS WORK, MATERIALS ARE OBSERVED WHICH ARE SUSPECTED TO CONTAIN ASBESTOS, THE CONTRACTOR SHALL IMMEDIATELY INFORM THE COR. WORK THAT WOULD EXPOSE WORKERS TO THE INHALATION OF ASBESTOS PARTICLES SHALL BE TERMINATED. WORK MAY BE RESUMED ONLY AFTER A DETERMINATION HAS BEEN MADE AND UNSAFE MATERIALS HAVE BEEN REMOVED OR
ENCAPSULATED AND THE AREA DECLARED SAFE.
14. ALL CUTTING AND PATCHING REQUIRED FOR THIS PROJECT SHALL BE INCLUDED IN THE CONTRACT. REFINISH ANY SURFACE DISTURBED
UNDER THIS WORK TO MATCH EXISTING.
15. ANY REMOVED EQUIPMENT SHALL BE TURNED OVER TO THE VA. ITEMS NOT DESIRED BY THE VA SHALL BE REMOVED FROM THE PREMISES
AND DISPOSED OF PROPERLY BY THE CONTRACTOR.
16. THE CONTRACT DRAWINGS ARE NOT INTENDED TO SHOW EVERY VERTICAL OR HORIZONTAL OFFSET. COORDINATE WORK IN ADVANCE WITH ALL OTHER TRADES AND REPORT IMMEDIATELY ANY DIFFICULTIES WHICH CAN BE ANTICIPATED.
17. FIELD VERIFY EXISTING CONDITIONS, INCLUDING PIPE AND EQUIPMENT SIZES, SERVICES AND LOCATIONS PRIOR TO PERFORMING WORK.
18. ALL EXISTING PIPING, EQUIPMENT, CONTROLS, ETC. SHOWN ON REMOVAL PLAN(S) SHALL BE REMOVED. THE MAJORITY OF WORK TO BE REMOVED IS SHOWN. REMOVE ALL INCIDENTAL AND/OR ABANDONED DUCTWORK, PIPING, ETC. THAT MAY NOT BE SHOWN BUT IS
ASSOCIATED WITH THE REMOVAL WORK.
19. ALL ABANDONED EXTRANEOUS PIPING, SUPPORTS, CONTROLS, ETC. SHALL BE REMOVED.
Tectonic Copyright 2007
B
C
EMS
A2025
SYSTEM COMPONENT RM
A2001B
MRI SCANNING RM
A2023MRI COMPONENT
A2007
Room
CORRIDOR-2
C-2-11-2
AVAIL.
A2021
CORRIDOR-3
C-2-11-3
CORRIDOR-1
C-2-11-1
SPECIAL PROCEDURES
A2015
S.P. CONTROL
A2009
MRI ROOM
A2001A
CONTROL ROOM
A2001
G C
R G
C S
2" 2"
UP2"
UP2"
B
C
EMS
A2025
SYSTEM COMPONENT RM
A2001B
MRI SCANNING RM
A2023MRI COMPONENT
A2007
Room
CORRIDOR-2
C-2-11-2
AVAIL.
A2021
CORRIDOR-3
C-2-11-3
CORRIDOR-1
C-2-11-1
SPECIAL PROCEDURES
A2015
S.P. CONTROL
A2009
MRI ROOM
A2001A
CONTROL ROOM
A2001
G C
R G
C S
2" 2"
UP2"
UP2"
AREA OF WORK
SECOND FLOOR
RM# A2001, A2001A, A2007
P: 937-224-0861 www.heapy.com
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
PROJECT NO.
STATE COA FIRM NO.
/2
/2
:3
:1
P
M
VA Cincinnati MRI Site Prep
05/30/2023
PARTIAL SECOND FLOOR PLAN -
REMOVALS AND NEW WORK
M101
MGNWJS
539-CSI-207
Cincinnati, OH
Bid Documents 22006.00
2022-05234
01528
Scale: 1/8" = 1'-0"2
PARTIAL SECOND FLOOR - NEW WORK
Scale: 1/8" = 1'-0"1
PARTIAL SECOND FLOOR - REMOVALS
N
N
PLAN NOTES:
1. EXISTING 1.5T MRI MACHINE BEING UPGRADED BY OTHERS. QUENCH VENT, ROOM
HVAC, ETC. ARE ALL EXISTING TO REMAIN.
2. REMOVE PIPING AS REQURED FOR INSTALLATION OF NEW COMPONENTS PER
SIEMENS AND HASKRIS INSTALLATION INSTRUCTIONS.
3. PROVIDE 27 GALLONS OF DEIONIZED WATER TO FILL THE SECONDARY WATER
CIRCUIT, PER HASKRIS INSTALLATION INSTRUCTIONS.
4. EXTEND 2" GLYCOL WATER PIPING TO NEW EQUIPMENT. PROVIDE ISOLATION BALL
VALVES, DRAIN VALVES, AND FLUSHING HOSE, PER HASKRIS INSTALLATION
INSTRUCTIONS. TERMINATE PIPING AT CABINETS WITH VIBRATION ISOLATORS.
5. DRAIN ENTIRE GLYCOL SYSTEM, FLUSH PIPING AND REFILL WITH A 40% PROPYLENE
GLYCOL MIXTURE, PER HASKRIS INSTALLATION INSTRUCTIONS. APPROXIMATE ROUTE
SHOWN. FIELD VERIFY.
6. MOUNT CHILLER REMOTE CONTROL PANEL FURNISHED BY HASKRIS. COORDINATE
EXACT LOACTION WITH SIEMENS AND VA. EXTEND WIRING TO CHILLER PER HASKRIS
INSTALLATION INSTRUCTIONS.
GENERAL NOTES:
A. SHUT DOWN OF EXISTING CHILLER AND STARTUP OF NEW CHILLER SHALL OCCUR OVER A
48 HOUR PERIOD. INSTALL NECESSARY EQUIPMENT PRIOR TO CHILLER REMOVAL IN
ORDER FOR SMOOTH AND TIMELY TRANSITION TO NEW CHILLER OPERATION.
UPUP
UP
UP
R
KRAUS
CHILLER
R
KRAUS
CHILLER
HASKRIS
R
KRAUS
CHILLER
HASKRIS
AREA OF WORK
THIRD FLOOR ROOF
LAG SCREW
4"x4"x1/4"
STEEL PLATE
FIBERGLASS INSULATION
INSULATION
ROOF
2x6 WOOD NAILER
ROOFING
ROOF DECK3
NOTES:
1. 18 GAUGE GALVANIZED STEEL COUNTER-FLASHING,
2. WELDED 14 GAUGE EQUIPMENT SUPPORT CURB, MEETING ASTM A-446, 525, 526 AND 527 REQUIREMENTS, WITH WELDED CORNERS WITH SEAMS JOINED BY CONTINUOUS WELDS. CURB SHALL BE INTERNALLY REINFORCED WITH BULKHEADS AND SPREADERS, 24" ON CENTER TO MEET LOAD RATING OF EQUIPMENT.
CURB TO EXTEND 6" BEYOND EQUIPMENT. REFER TO FLOOR PLANS FOR HEIGHT.
3. SECURE CURB TO ROOF WITH EXPANSION BOLTS (CONCRETE ROOF) OR RUST RESISTANT BOLTS
(METAL DECK AND BAR JOIST ROOF), 12" O.C.
P: 937-224-0861 www.heapy.com
VA Project No.
RDC/JPA Project No.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Office of Construction and Facilities Management
PROJECT NO.
STATE COA FIRM NO.
/2
/2
:3
:1
P
M
VA Cincinnati MRI Site Prep
05/30/2023
PARTIAL THIRD FLOOR PLAN -
REMOVALS AND NEW WORK
M102
MGNWJS
539-CSI-207
Cincinnati, OH
Bid Documents 22006.00
2022-05234
01528
Scale: 1/4" = 1'-0"1
PARTIAL THIRD FLOOR (ROOF)-HVAC-STEP 1
Scale: 1/4" = 1'-0"2
PARTIAL THIRD FLOOR (ROOF)-HVAC-STEP 2
Scale: 1/4" = 1'-0"3
PARTIAL THIRD FLOOR (ROOF)-HVAC-STEP 3
PLAN NOTES:
1. EXTEND NEW 2" GLYCOL WATER PIPING TO NEW CHILLER. COVER INSULATION WITH
TWO COATS OF WEATHER RESISTANT FINISH AS SPECIFIED.
2. REMOVE CHILLED WATER PIPING BACK TO POINT INDICATED FOR CONNECTION TO
NEW CHILLER IN STEP 3. NEW CHILLER SHALL BE INSTALLED AND HAVE POWER
PRIOR TO REMOVAL.
3. REMOVE EXISTING CHILLER ONCE NEW CHILLER IS OPERATIONAL.
4. REMOVE EQUIPMENT CURBS ONCE NEW CHILLER IS OPERATIONAL.
5. PROVIDE EQUIPMENT SUPPORT CURBS IN STEP 1 FOR CHILLER TO BE INSTALLED IN
STEP 2.
6. RECEIVE AND INSTALL HASKRIS MODEL OPC24 CHILLER FURNISHED BY SIEMENS.
7. EXISTING EXHAUST FAN TO REMAIN.
8. EXISTING CONDENSING UNIT TO REMAIN.
9. EXISTING PIPE PENETRATION ROOF CURB TO REMAIN.
10. PROVIDE ISOLATION BALL VALVES, PURGE VALVES (WITH ISOLATION BALL VALVES)
AND DRAIN VALVES, PER HASKRIS INSTALLATION INSTRUCTIONS. TERMINATE PIPING
AT CHILLER WITH VIBRATION ISOLATORS.
11. INTEGRATE CHILLER INTO HOSPITAL TRIDIUM NIAGARA AX CONTROLS SYSTEM VIA
BACNET FOR MONITORING ONLY. CONNECT TO CHILLER CONTROLLER LOCATED IN
HIGH VOLTAGE ELECTRIC BOX. TRIDIUM JACE LOCATED ON 4TH FLOOR ADJACENT TO
SERVICE ELEVATORS.
GENERAL NOTES:
A. SHUT DOWN OF EXISTING CHILLER AND STARTUP OF NEW CHILLER SHALL OCCUR OVER A
48 HOUR PERIOD. INSTALL NECESSARY EQUIPMENT PRIOR TO CHILLER REMOVAL IN
ORDER FOR SMOOTH AND TIMELY TRANSITION TO NEW CHILLER OPERATION.
B. COORDINATE RECEIPT OF, POTENTIAL STORAGE FOR, AND INSTALLATION
REQUIREMENTS FOR, NEW HASKRIS CHILLER WELL IN ADVANCE OF ANY SYSTEM SHUT
DOWNS.
N
N
N
N.T.S.Scale:
EQUIPMENT SUPPORT ROOF CURB
Revisions Date
VHACINReynoM Highlight
SWBD
METERING
SWBD
METERING
ELECTRICAL SYMBOLS
EXISTING OUTLET OR DEVICE TO REMAIN. MAINTAIN EXISTING CIRCUITING.
DASH SYMBOL INDICATES PARTICULAR OUTLET OR DEVICE TO BE REMOVED AND CIRCUITRY MADE CONTINUOUS WHERE
REQUIRED.
ELECTRICAL CONNECTION.
20A-125V SINGLE RECEPTACLE, NEMA 5-20R (18" MH UNLESS NOTED OTHERWISE).
SPECIAL PURPOSE RECEPTACLE. REFER TO NOTE ON PLAN.
20A-125V DOUBLE DUPLEX RECEPTACLE. NEMA 5-20R, (18" MH UNLESS NOTED OTHERWISE) TWO GANG ASSEMBLY.
20A-125V DUPLEX RECEPTACLE, NEMA 5-20R, WITH GROUND FAULT CIRCUIT INTERRUPTER (18" MH UNLESS NOTED
OTHERWISE).
20A-125V WEATHERPROOF DUPLEX RECEPTACLE, NEMA 5-20R (HORIZONTAL 18" MH UNLESS NOTED OTHERWISE) WITH
TAYMAC #MM420G EXTRA DUTY GRAY COVER, VERTICAL MOUNT.
20A-125V WEATHERPROOF DUPLEX RECEPTACLE, NEMA 5-20R WITH GROUND FAULT CIRCUIT INTERRUPTER (18" MH UNLESS NOTED OTHERWISE), WITH TAYMAC #MM420G EXTRA DUTY GRAY COVER, VERTICAL MOUNT.
JUNCTION BOX. SQUARE DEVICE INDICATES A CONNECTION TO CRITICAL POWER.
MULTI-OUTLET RECEPTACLES ASSEMBLY, NEMA 5-15R (SINGLE OUTLETS ON 18" CENTERS) (46" MH UNLESS NOTED
OTHERWISE).
DISCONNECT SWITCH.
MOTOR STARTER.
COMBINATION MOTOR STARTER AND DISCONNECT SWITCH.
ELECTRIC MOTOR.
ELECTRICAL PANEL OR SWITCHBOARD PER DRAWINGS.
GF
WP
WP/GF
J
20A-125V DUPLEX RECEPTACLE, NEMA 5-20R (46" MH UNLESS NOTED OTHERWISE).
ABBREVIATIONS
AAP - AREA ALARM PANEL - MEDICAL GAS
ACC - ACCESS
ADJ - ADJUSTABLE
AF - ARC FAULT CIRCUIT INTERRUPTER
AFCI - ARC FAULT CIRCUIT INTERRUPTER
AFF - ABOVE FINISHED FLOOR TO BOTTOM OF ITEM
AFG - ABOVE FINISHED GRADE TO BOTTOM OF ITEM
ALT - ALTERNATE
AP - ACCESS PANEL
APPROX - APPROXIMATE
ARCH - ARCHITECT OR ARCHITECTURAL
ASSY - ASSEMBLY
ATS - AUTOMATIC TRANSFER SWITCH
BLDG - BUILDING
BOE - BOTTOM OF EQUIPMENT
BOT - BOTTOM
BTWN - BETWEEN
CFCI - CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CKT - CIRCUIT
CLG - CEILING
CMU - CONCRETE MASONRY UNIT
CONN - CONNECT OR CONNECTION
CONTR - CONTRACTOR
CORR - CORRIDOR
CTR - CENTER
D - DEPTH
DET - DETAIL
DIA - DIAMETER
DIM - DIMENSION
DIV - DIVISION
DN - DOWN
DWG - DRAWING
EA - EACH
EC - DIVISION 26 CONTRACTOR
EJ - EXPANSION JOINT
ELEC - ELECTRICAL
ELEV - ELEVATION OR ELEVATOR
EM - EMERGENCY
EQ - EQUAL
EQS - EQUIPMENT SUPPLIER
EQUIP - EQUIPMENT
E/R - EXISTING TO BE RELOCATED
EX - EXISTING TO REMAIN
EXP - EXPANSION
EXT - EXTERIOR
FCE - FIRE CONTROL EQUIPMENT
FF - FINISHED FLOOR ELEVATION
FLR - FLOOR
FSC - DIVISION 21 CONTRACTOR
FT - FEET
FTG - FOOTING
GC - GENERAL CONTRACTOR
GF - GROUND FAULT CIRCUIT INTERRUPTER
GFCI - GROUND FAULT CIRCUIT INTERRUPTER
HC - DIVISION 23 CONTRACTOR
HP - HORSE POWER OR HIGH POINT
HVAC - HEATING, VENTILATING, AND AIR CONDITIONING
ID - INSIDE DIAMETER
IN - INCHES
KEC - KITCHEN EQUIPMENT CONTRACTOR
L - LENGTH
LBS - POUNDS
MAP - MASTER ALARM PANEL (MEDICAL GAS)
MAX - MAXIMUM
MEZZ - MEZZANINE
MFR - MANUFACTURER
MH - MANHOLE OR MOUNTING HEIGHT TO CENTER LINE OF ITEM
MIN - MINIMUM OR MINUTE
MISC - MISCELLANEOUS
MTD - MOUNTED
MTG - MOUNTING
NIC - NOT IN CONTRACT
NOM - NOMINAL
NTS - NOT TO SCALE
OD - OUTSIDE DIAMETER
OFCI - OWNER FURNISHED CONTRACTOR INSTALLED
OFOI - OWNER FURNISHED OWNER INSTALLED
PC - DIVISION 22 CONTRACTOR
PLBG - PLUMBING
RAD - RADIUS
REC - RECESSED
REQD - REQUIRED
RI - ROUGH-IN
S - SURFACE MOUNTED
SC - SECURITY CONTRACTOR
SCH - SCHEDULE
SHT - SHEET
SMS - SECURITY MANAGEMENT SYSTEM
SPEC - SPECIFICATIONS
SQ - SQUARE
SS - STAINLESS STEEL
STD - STANDARD
STRUC - STRUCTURAL OR STRUCTURE
SUC - SITE UTILITY CONTRACTOR
TC - DIVISION 27 CONTRACTOR
TEMP - TEMPERATURE
TOE - TOP OF EQUIPMENT
TYP - TYPICAL
UNO - UNLESS NOTED OTHERWISE
VFD - VARIABLE FREQUENCY DRIVE
VOL - VOLUME
W/ - WITH
W/O - WITHOUT
WP - WEATHERPROOF
ZVC - ZONE VALVE CABINET
WIREMOLD RACEWAY, AS NOTED ON PLANS.
20A-125V DUPLEX RECEPTACLE, NEMA 5-20R WITH 2 INTEGRAL USB CHARGERS (18" MH UNLESS NOTED OTHERWISE).
NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT
TO MODIFICATIONS ON OTHER DRAWINGS.
ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT
NECESSARILY BE USED ON THIS PROJECT.
SQUARE DEVICE INDICATES A CONNECTION TO CRITICAL POWER. SPECIFICATION IS SAME AS RESPECTIVE ROUND DEVICE.
J
E2
B
E2
DETAIL: B = DETAIL DESIGNATION
E2 = SHEET WHERE DETAIL IS LOCATED
SECTION: 1 = SECTION DESIGNATION
E2 = SHEET WHERE SECTION IS LOCATED
PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWN.
DETAIL NOTE.