Replace Air Storage System
Solicitation number
N6264926QB022
Issued by

About this file

This document contains technical connection diagrams for a high-pressure pneumatic system upgrade at a facility with SCBA maintenance capabilities. The diagrams illustrate the current system configuration and the proposed replacement design for pneumatic equipment used to support Self-Contained Breathing Apparatus (SCBA) maintenance operations.

The current system (Enclosure 1) operates with two existing High-Pressure Air Compressors (HPACs) each rated at a maximum of 6,000 psig, feeding into four existing cylinders—two cylinders rated for 5,000 psig systems and two cylinders rated for 3,000 psig systems. The system includes pressure regulation at 5,500 psig for the SCBA maintenance room and 3,500 psig for the pneumatic room, with an out-of-service pressure sensor and relief/needle valves. The proposed replacement design (Enclosure 2) upgrades the four existing cylinders to new 6,000 psig-rated cylinders across all four positions, maintains the same dual HPAC configuration, and introduces a new regulatory structure with a relief valve, a regulator set to 4,000 psig, and adjusted pressure settings of 3,150 to 3,450 psig for the pneumatic room. The replacement includes a pressure gauge scaled 0 to 10,000 psig and reinstates functional pressure monitoring for the system while improving overall system capacity and pressure management capabilities.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Blow to atm

Final filter unit

Set 5,500 psig

Ex is tin g cy lin de r

(1 fo r

5, ps ig s ys te m

Ex is tin g cy lin de r

(2 fo r

5, ps ig s ys te m

Final filter unit

Ex is tin g cy lin de r

(3 fo r

3, ps ig s ys te m

Ex is tin g cy lin de r

(4 fo r

3, ps ig s ys te m

SCBA Maintenance Room

Scope of Replacement

Set 3,500 psig Pressure sensor (out of service)

Needle valve

Pneumatic Room

Existing HPAC (1) Max. 6,000 psig

Existing HPAC (2) Max. 6,000 psig

RV

RV

Connection Diagram (Current)

Enclosure (1)

Existing HPAC (1) Max. 6,000 psig

Blow to atm

Final filter unit

N ew

,0 p si g cy lin de r

(1 fo r

6, ps ig s ys te m

Existing HPAC (2) Max. 6,000 psig

Final filter unit

Replaced Components

N ew

,0 p si g cy lin de r

(2 fo r

6, ps ig s ys te m

Pneumatic Room

SCBA Maintenance Room

Set 3,150 to 3,450 psig

R

Regulator set to 4,000 psig

0 to 10,000 psig

RV RV

N ew

,0 p si g cy lin de r

(3 fo r

3, ps ig s ys te m

N ew

,0 p si g cy lin de r

(4 fo r

3, ps ig s ys te m

RV RV

Needle valve

Relief valve

RV

Connection Diagram (After Replacement)

Enclosure (2)

シートとビュー
X31 AIR FLASK_FY25-Encl 1
X31 AIR FLASK_FY25-Encl 2