Attachment II - Drawings set 1 of 6.pdf

PDF 23 MB Posted

Attached to
Z1DA--Improve Sewer System and Water Loop 610-21-104 Federal contract opportunity
Solicitation number
36C25025B0007
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

This file contains construction drawings showing detailed topographic surveys, utility surveys, and site plans for improving the sewer system and water loop at the VA Northern Indiana Health Care System facility in Marion, Indiana (Project No. 610.21.104).

The drawings include comprehensive site surveys showing existing conditions, utilities, and infrastructure across multiple areas of the campus, with detailed elevation information, utility locations (water, sewer, steam, electrical, etc.), and site features. The drawings contain plan views, details of buildings, roads, walkways, and utilities including sanitary sewer lines, storm sewers, steam lines, and water mains. Survey information includes rim elevations, pipe inverts, pipe sizes, and materials. The drawings are prepared by Viridian Architectural Design and dated July 31, 2023, with survey work conducted between March 2021 and May 2023. The plans appear to be part of a larger set of construction documents for improvements to campus utility infrastructure, focusing on water and sewer systems.

View the file

Other files for this federal contract opportunity

Other files attached to Z1DA--Improve Sewer System and Water Loop 610-21-104, newest first.
File Type Posted
36C25025B0007 0011.pdf PDF
Attachment - Updated DB WD.pdf PDF
Attachment - 2nd Set RFI Questions and Answers.pdf PDF
Attachment - 321723.pdf PDF
Attachment - 331000.pdf PDF
Attachment - 329000.pdf PDF
Attachment - RFI Questions and Answers.docx DOCX document
36C25025B0007 0010.pdf PDF
36C25025B0007 0009.pdf PDF
Site Walk Sign-In Sheet - Improve Sewer System and Water Loop.pdf PDF
36C25025B0007 0008.pdf PDF
36C25025B0007 0007.pdf PDF
36C25025B0007 0006.pdf PDF
36C25025B0007 0005.pdf PDF
36C25025B0007 0004.pdf PDF
36C25025B0007 0003.pdf PDF
36C25025B0007 0002.pdf PDF
36C25025B0007 0001.pdf PDF
Attachment VIII - Specs.pdf PDF
Attachment V - Drawings set 4 of 6.pdf PDF
Attachment I - WD.pdf PDF
Attachment X - EMR.docx DOCX document
Attachment IX - Limitation on Subcontracting Cert.pdf PDF
Attachment VII - Drawings set 6 of 6.pdf PDF
Attachment IV - Drawings set 3 of 6.pdf PDF
Attachment XI - RFI Form-36C25025B0007.docx DOCX document
Attachment VI - Drawings set 5 of 6.pdf PDF
Attachment III - Drawings set 2 of 6.pdf PDF
36C25025B0007.docx DOCX document
Show all 29

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8707 / 31 / 2023

1. THIS SURVEY WAS PERFORMED FOR THE EXPRESS PURPOSE OF MAPPING THE EXISTING TOPOGRAPHIC FEATURES FOR THE

PROJECT SITE AT THE MARION VA MEDICAL CENTER IN MARION, INDIANA.

2. THE UNDERGROUND UTILITY INFORMATION REPRESENTED ON THIS DRAWING WAS DELINEATED USING RECORD INFORMATION, BY FIELD MEASUREMENTS OF VISUAL APPURTENANCES, AND BY A SITE UTILITY-LOCATION SURVEY CONDUCTED BY MASON

PRIVATE LOCATING, (888) 316-3933. ADDITIONAL UNDERGROUND UTILITIES MAY EXIST, THE LOCATIONS OF WHICH WERE NOT DETERMINED AT THE TIME OF THIS SURVEY. ALL UTILITY LOCATIONS ARE APPROXIMATE ONLY.

3. THE LOCATIONS AND DIMENSIONS OF ALL BUILDING STRUCTURES ON THE FACE OF THIS SURVEY ARE APPROXIMATED FOR REFERENCE ONLY. BUILDING DIMENSIONS ARE NOT INTENDED TO BE SCALED FOR STRUCTURAL DETAILING/ DESIGN.

4. THE HORIZONTAL COORDINATES REPRESENTED HEREIN ARE PROJECTED TO NGS NAD 83, INDIANA STATE PLANE EAST. VERTICAL COORDINATES REPRESENTED HEREIN ARE PROJECTED TO NAVD 88. SEE SHEET C0.0 FOR VERTICAL AND HORIZONTAL CONTROL

POINT DESCRIPTIONS.

5. THE DELINEATION OF WETLANDS OR OTHER ENVIRONMENTAL CONDITIONS WERE NOT CONSIDERED AS A PART OF THIS SURVEY.

6. THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RE-TRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY

OR A SURVEYOR LOCATION REPORT.

GENERAL NOTES:

CERTIFICATION:

THE UNDERSIGNED LAND SURVEYOR, REGISTERED UNDER THE LAWS OF THE STATE OF INDIANA, HEREBY CERTIFIES THAT HE HAS MADE A TOPOGRAPHICAL AND UTILITY SURVEY OF THE AREA DEPICTED. I HEREBY CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF THAT THIS PLAT REPRESENTS A TOPOGRAPHIC AND UTILITY SURVEY CONDUCTED UNDER MY DIRECT SUPERVISION.

PROJECT NO.: 21093.100

SURVEYED FOR: VIRIDIAN ARCHITECTURAL DESIGN

DATE(S) OF FIELDWORK: MARCH 23, 2021 - MAY 5, 2021

JANUARY 11, 13, 24, & 27, 2022

APRIL 27, 2022

MAY 6, 2022

APRIL 17, 18, & 20, 2023

MAY 2, 3, & 5, 2023

IN WITNESS THEREOF, I HEREUNTO PLACE MY

HAND AND SEAL THIS 9th DAY OF MAY, 2023.

ROSS M. FRANK

INDIANA REGISTERED LAND SURVEYOR NO. 20500021

Horizontal & Vertical Control

Point #

BM#7300

BM#7301

BM#7302

BM#7303

BM#7304

BM#7305

BM#7306

BM#7307

BM#7308

BM#7309

BM#7310

BM#7311

BM#7312

BM#7313

BM#7314

HCV#31000

HCV#31004

HCV#31005

HCV#31006

HCV#31007

HCV#31008

HCV#31010

HCV#31013

HCV#31015

HCV#31019

HCV#31020

HCV#31022

HCV#31025

HCV#31027

HCV#31030

HCV#31031

HCV#31100

HCV#37001

HCV#37002

HCV#37003

HCV#37009

HCV#37012

HCV#37014

HCV#37016

HCV#37017

HCV#37018

HCV#37021

HCV#37023

HCV#37024

HCV#37026

Northing

1920885.4±

1920759.7±

1921223.5±

1921484.2±

1921016.3±

1920924.5±

1920294.8±

1919807.2±

1919171.2±

1920189.6±

1920388.4±

1920702.1±

1921297.6±

1921501.5±

1919529.8±

1920874.42

1921208.17

1921471.29

1921152.04

1920939.91

1920928.61

1921388.32

1920720.90

1919771.86

1919158.19

1919374.78

1919512.77

1920170.98

1920740.17

1919450.51

1921532.39

1919453.66

1920848.92

1921113.60

1921464.86

1920940.32

1921595.77

1920254.94

1919716.76

1919531.42

1919165.32

1919277.33

1919709.39

1919899.06

1920381.06

Easting

336078.7±

336613.6±

336806.5±

337082.5±

337203.0±

337634.1±

338044.4±

338092.1±

337432.5±

337596.2±

337159.9±

337102.0±

338119.1±

337156.7±

336935.5±

336063.44

336740.95

337088.43

337103.62

337305.92

337691.70

338110.59

338017.39

338183.01

337583.57

337296.52

336862.69

337590.47

337053.46

338427.81

337103.57

337401.94

336624.48

336495.55

336354.32

338168.49

338293.68

338020.45

337659.68

337988.85

338215.76

337076.84

337307.84

337140.64

337236.48

Elev. (NAVD88)

844.86

841.03

838.87

838.92

832.42

834.20

837.45

844.20

846.06

845.99

843.38

840.70

838.49

841.30

843.98

842.60

837.97

839.43

832.12

831.96

835.70

833.89

835.44

838.30

843.84

845.63

840.55

845.47

839.86

833.51

838.41

846.22

837.42

836.08

838.80

839.59

826.51

838.09

844.81

844.16

837.70

843.71

844.48

844.40

843.16

Description

SW BONNET BOLT OF HYDRANT #34

CHISELED 'X' IN E SIDE OF LIGHT POLE

CHISELED '☐' IN CENTER OF CONCRETE PAD

CHISELED '☐' IN TOP OF CURB, 15' N OF LIGHT POLE

CHISELED '☐' IN TOP OF CURB, 10' NW OF CURB CAST INLET

CHISELED '☐' AT END OF CURB

CHISELED '☐' IN RETAINING WALL, NE CORNER OF CHAPMAN & ORCHARD

CHISELED 'X' IN E BONNET BOLT OF HYDRANT #16

CHISELED '☐' IN NE CORNER OF LIGHT POLE BASE

CHISELED '☐' IN TOP OF CURB, S SIDE OF FLOWER & CHAPMAN

CHISELED 'X' IN SW SIDE OF ELECTRIC MANHOLE

CHISELED 'X' IN N RIM OF MANHOLE

ESE BONNET BOLT OF HYDRANT

CHISELED 'X' IN NNE BONNET BOLT OF HYDRANT

CHISELED 'X' IN S BONNET BOLT OF HYDRANT

MAG NAIL IN S SIDE OF WALK

24" REBAR W/ BFA CAP

MAG NAIL IN TOP OF CURB (RECORD CONTROL POINT #1)

MAG NAIL (RECORD CONTROL POINT #3)

REBAR W/ CAP (RECORD CONTROL POINT #7)

MAG NAIL (RECORD CONTROL POINT #6)

MAG NAIL IN NW CORNER OF KUDER & HYDE

MAG NAIL IN TOP OF CURB, W SIDE OF MISSISSINEWA ROAD

24" REBAR W/ BFA CAP

MAG NAIL IN N SIDE OF BLACK ROAD

MAG NAIL 15' NE OF BUILDING #76

MAG SPIKE IN S SIDE OF WATER STREET

24" REBAR W/ BFA CAP, 20' S OF CURB AT FLOWER & CHAPMAN

MAG SPIKE IN SW CURB AT STEELE/INDIANA

MAG NAIL IN PAVEMENT, S SIDE OF BLACK ROAD

MAG NAIL IN PAVEMENT AT 38TH & MAIN ENTRANCE

MAG NAIL IN PAVEMENT, SE CORNER OF BUILDING #51

MAG NAIL IN N SIDE OF WALK, 10' W OF MANHOLE

DIMPLE IN NE RIM OF INLET

MAG NAIL IN S END OF CURB ISLAND

MAG NAIL IN S SIDE OF INDIANA AVE BETWEEN MISSISSINEWA & HYDE

CHISELED '☐' IN SE SIDE OF LIFT STATION

REBAR W/CAP SE OF ORCHARD & CHAPMAN (RECORD CONTROL POINT #4)

MAG NAIL IN CONCRETE

CHISELED 'X' IN NE CORNER OF CONCRETE PAD FOR ELECTRIC MANHOLE

MAG NAIL IN W SIDE OF BLACK ROAD

MAG NAIL IN CONCRETE JOINT, 20' W OF SHORT STREET

MAG NAIL IN NE CORNER OF CONCRETE PAD FOR VAULT

MAG NAIL IN TOP OF CURB, 5' W OF CURB CAST INLET

MAG NAIL IN CONCRETE PAD AT CURB ISLAND OF STEELE & CHAPMAN

HCV#31150

HCV#31151

1921227.14 335443.15

1921381.41 335651.41

845.94

842.36

MAG NAIL SET IN PAVEMENT, 17' SOUTHEAST OF END OF S HOME AVE ROAD

5/8" X 48" REBAR W/BFA CAP, 27' SOUTHEAST OF FENCE

BM#7500

BM#7501

BM#7502

BM#7503

1919794.9±

1919888.8±

1920086.4±

1920077.7±

336778.5±

336355.8±

336831.4±

336660.8±

844.36

842.57

846.49

844.80

WEST BONNET BOLT OF HYDRANT

NORTH BONNET BOLT OF HYDRANT

NORTH BONNET BOLT OF HYDRANT

NORTH BONNET BOLT OF HYDRANT

E 38TH STREET

M

IS

S

IS

S

IN

E W

A R

IV

E R

S C

E N

TR

A L A

VE

N U E

PROJECT

LOCATION

PA

RK

IN

G

PARKING

PARKING

PA

RK

IN

G

PARKING

PARKING PARKING

PARKING

SCALE 1" = 2,000' ±

Site Location Map 75'150' 150'

SCALE 1" = 150'

Sheet Layout Map

SCALE: 1" = 150'

C0.1

NORTHNORTH

FLAG POLE

I

L

PM

RWM

W

YD

SQUARE/RECTANGULAR STORM INLETCB

WATER CURB STOP

W

CS

COMMUNICATION UTILITIES VAULTC

COMMUNICATION BOXC

COMMUNICATION UTILITIES PEDESTALC

PED

COMMUNICATION UTILITIES MANHOLEC

GAS METERG

GAS VALVE (TYP.)

G

WATER METERW

WATER VALVE (TYP.)

W

FIRE HYDRANT

POST INDICATOR VALVEPIV

IRRIGATION CONTROL VALVEICV

YARD HYDRANTYH

WATER UTILITIES MANHOLEW

POWER POLE/ UTILITY POLE

LIGHT POLELP

TRANSFORMER PADTP

ELECTRICAL BOXEB

ELECTRICAL METERM

GUY ANCHOR

ELECTRICAL UTILITIES MANHOLEE

ELECTRICAL PANELPP

ELECTRIC UTILITIES VAULTE

YARD LIGHTYL

STORM DRAINAGE MANHOLED

ROUND STORM DRAINAGE INLETCB

SANITARY SEWER MANHOLES

CLEANOUTCO

DECIDUOUS TREE

CONIFEROUS TREE

BUSH (DECIDUOUS)

BUSH (CONIFEROUS)

BOULDER

HORIZONTAL CONTROL POINTHC

BENCHMARK

BOUNDARY MONUMENTIP

OVERHEAD UTILITY- MULTIPLE SVCS. (EXST.)OHU

DOWNSPOUTDS FINISHED FLOOR ELEVATION

BOLLARDB

MAILBOXMB

SINGLE-POST SIGN

DOUBLE-POST SIGN

CONCRETE MATERIAL

PAVEMENT MATERIAL

GRAVEL/STONE MATERIAL

BUILDING (ENCLOSED)

SAN: SANITARY SEWER (EXST.)

STM: STORM SEWER (EXST.)

OVERHEAD ELECTRIC LINE (EXST.)OE

UNDERGROUND ELECTRIC LINE (EXST.)UE

OVERHEAD TELECOM/DATA LINE (EXST.)OC

UNDERGROUND TELECOM/DATA LINE (EXST.)UC

UNDERGROUND FIBER OPTIC LINE (EXST.)FO

GAS LINE (EXST.)G

WATER LINE (EXST.)W

HAND RAILo o

FENCE LINE (TYP.)[] []

CHAIN-LINK FENCE LINEx x

EDGE OF LANDSCAPING

BUILDING (OPEN-AIR CANOPY)

GAS CURB STOP

ELETRICAL HANDHOLE

IRRIGATION SIDEWALK CROSSING

LIFT STATION MANHOLE

MONITORING WELL

PARKING BLOCK

PARKING METER

RIGHT OF WAY MARKER

SOIL BORING

LAWN SPRINKLER HEAD

GAS UTILITIES VAULT

WATER UTILITIES VAULT

WATER LEVEL

WELL

YARD DRAIN

AIR CONDITIONING UNIT

ADA DOOR BUTTON

FLAGPOLE

ELECTRIC UTILITIES PEDESTALE

PED

POST/FENCE GATE

ADA SYMBOL

BURIED LINE - WARNING RISER!

TRAFFIC UTILITIES MANHOLE/HAND HOLETF

TRAFFIC UTILITIES VAULTTF

STRAIN POLESP

TRAFFIC CONTROLS CABINET/ PEDESTALTF

PED

G

CS

G

AC

H

W

UU

UNDERGROUND FIBER OPTIC LINE (RECORD)FO

UNDERGROUND UTILITY- MULTIPLE SVCS. (EXST.)UU

OVERHEAD FIBER OPTIC LINE (EXST.)OFO

OFO

OVERHEAD TRAFFIC CONTROL LINE (EXST.)OTR

OTR

UNDERGROUND TRAFFIC CONTROL LINE (EXST.)UTR

FARM FIELD TYPE FENCE

GUARDRAIL

SANITARY SEWER (RECORD)SS

WATER LINE (RECORD)W

STORM SEWER (RECORD)ST

GAS LINE (RECORD)G

UNDERGROUND PRIMARY ELECTRIC LINE (EXST.)PE

UNDERGROUND PRIMARY ELECTRIC LINE (RECORD)PE

UNDERGROUND ELECTRIC LINE (RECORD)UE

UNDERGROUND TELECOM/DATA LINE (RECORD)UC

UNDERGROUND UTILITY- MULTIPLE SVCS. (RECORD)

OVERHEAD FIBER OPTIC LINE (RECORD)

OVERHEAD TRAFFIC CONTROL LINE (RECORD)

UNDERGROUND TRAFFIC CONTROL LINE (RECORD)UTR

IRRIGATION LINE (EXST.)IRR

IRRIGATION LINE (RECORD)IRR

OVERHEAD ELECTRIC LINE (RECORD)OE

OVERHEAD UTILITY- MULTIPLE SVCS. (RECORD)OHU

OVERHEAD TELECOM/DATA LINE (RECORD.)OC

TUNNEL (RECORD)

TUNNEL (EXST.)

CHILLED WATER LINE (EXST.)CW

CHILLED WATER LINE (RECORD)CW

HOT WATER LINE (EXST.)HW

HOT WATER LINE (RECORD)HW

SS SANITARY SEWER (EXST.)

ST STORM SEWER (EXST.)

C0.3

C0.5

C0.7 C0.8

C0.6

C0.4

C0.2

THE BELOW ELEVATIONS ARE BASED UPON N.G.S BENCHMARK "MARION RM 1" (PID LA1585),

LOCATED OUTSIDE OF PROJECT LIMITS, WHOSE ELEVATION IS 845.81' (NAVD88)

C0.9

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

CONSTRUCTION

DOCUMENT

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

Viridian Architectural Design, Inc.

2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46808

PH: 260.424.4830

www.viridian-design.net

Civil Engineering:

Improve Sewer System and Water Loop

Marion, Indiana

610-21-104

Campus Project Director

06 / 15 / 2023Revisions: Date:

VIRIDIAN

ARCHITECTURAL DESIGN INC.

Engineering Resources, Inc.

4175 New Vision Dr., Fort Wayne, IN 46845

PH: 260-490-1025

Website: ericonsulting

All concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural Design Inc. and shall not be used for any purpose without prior expressed written consent. The Contracting Officer Representative shall be permitted to retain copies for information and reference.

OF 858707 / 31 / 202307 / 31 / 2023

1. THIS SURVEY WAS PERFORMED FOR THE EXPRESS PURPOSE OF MAPPING THE EXISTING TOPOGRAPHIC FEATURES FOR THE

2. THE UNDERGROUND UTILITY INFORMATION REPRESENTED ON THIS DRAWING WAS DELINEATED USING RECORD INFORMATION, BY FIELD MEASUREMENTS OF VISUAL APPURTENANCES, AND BY A SITE UTILITY-LOCATION SURVEY CONDUCTED BY MASON

PRIVATE LOCATING, (888) 316-3933. ADDITIONAL UNDERGROUND UTILITIES MAY EXIST, THE LOCATIONS OF WHICH WERE NOT DETERMINED AT THE TIME OF THIS SURVEY. ALL UTILITY LOCATIONS ARE APPROXIMATE ONLY.

3. THE LOCATIONS AND DIMENSIONS OF ALL BUILDING STRUCTURES ON THE FACE OF THIS SURVEY ARE APPROXIMATED FOR REFERENCE ONLY. BUILDING DIMENSIONS ARE NOT INTENDED TO BE SCALED FOR STRUCTURAL DETAILING/ DESIGN.

4. THE HORIZONTAL COORDINATES REPRESENTED HEREIN ARE PROJECTED TO NGS NAD 83, INDIANA STATE PLANE EAST. VERTICAL COORDINATES REPRESENTED HEREIN ARE PROJECTED TO NAVD 88. SEE SHEET C0.0 FOR VERTICAL AND HORIZONTAL CONTROL

POINT DESCRIPTIONS.

5. THE DELINEATION OF WETLANDS OR OTHER ENVIRONMENTAL CONDITIONS WERE NOT CONSIDERED AS A PART OF THIS SURVEY.

6. THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RE-TRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY

OR A SURVEYOR LOCATION REPORT.

GENERAL NOTES:

CERTIFICATION:

THE UNDERSIGNED LAND SURVEYOR, REGISTERED UNDER THE LAWS OF THE STATE OF INDIANA, HEREBY CERTIFIES THAT HE HAS MADE A TOPOGRAPHICAL AND UTILITY SURVEY OF THE AREA DEPICTED. I HEREBY CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF THAT THIS PLAT REPRESENTS A TOPOGRAPHIC AND UTILITY SURVEY CONDUCTED UNDER MY DIRECT SUPERVISION.

PROJECT NO.: 21093.100

SURVEYED FOR: VIRIDIAN ARCHITECTURAL DESIGN

DATE(S) OF FIELDWORK: MARCH 23, 2021 - MAY 5, 2021

IN WITNESS THEREOF, I HEREUNTO PLACE MY

HAND AND SEAL THIS 10th DAY OF MAY, 2021.

ROSS M. FRANK

INDIANA REGISTERED LAND SURVEYOR NO. 20500021

LP

LP

CO

C

G

TP

TP

E

D

S

S

S

CB

D

S

D

S

D

S

S

CB

HC

HC

HC

HC

C

PED

E

W

CB

D

CB

C

PED

D

S

E

S

S

S

D

S

D

CB

D

CB

D

CB

S

S

E

CB

HC

EB

C

PED

C

PED

MB

W

MBMBMB

C

PED

C

PED

MB

W

MB

W

W

CB

CB

S

CB

CB

CB

DCBCB

CBCBCB

D

CB

CB

S

CB

CB

CB

CBCBCB

CBCB

CB

DD

IP IP

CB

CB

CB

D

D

S

S

E

LP

LP

CBCB

VINE ROAD

PARK DRIVE

D

IX

R O

A D

VINE ROAD

E 38th STREET

E 38th STREET

G E

O R

G

IA

S T

R E

E T

BM#7302

BM#7303

BM#7313

HCV#31004

HCV#31031

HCV#37003

HCV#31005

HCV#31006

BUILDING 32

SINGLE QUARTERS

BUILDING 91

1-CAR GARAGE

BUILDING 125

2-CAR GARAGE

BUILDING 33

DUPLEX QUARTERS

839.20 838.96

838.96

838.40

837.83

836.15 836.23

836.81 837.58 838.76 839.60 840.24 840.53

838.72

838.14

837.43

835.89 835.97

836.59 837.32 838.43 839.35 839.97 840.48

838.58 838.22

838.18 837.85

837.66 837.43

837.00

836.17 836.16

836.72 837.49 837.20836.72

835.78 835.79

836.46 838.30

837.88 839.33

839.04

840.56

840.30 840.91

838.85 838.56

.9

.7

9.

8.

839.33

838.95

838.39

837.80

837.09

836.24 836.34

837.01 837.71 838.83

836.92

836.69 840.54

839.48 841.34

839.64 839.94

839.86

839.95 841.08

841.16 840.84

840.86 840.13

839.56

.7

.7

.0

.0

.8

.7

.5

.5

.4

.4

.0

.0

.9

.9

839.89

840.80 840.83

836.20

839.34839.66 839.52

837.38

835.51

840.74

843.76 840.76

835.62

831.99 831.26

832.34 835.61

837.68

838.18

837.84 838.31

839.96 840.18

840.26

838.88

.4

.1

.2

.5

.2

.7

.9

.9

.4

.3

.3

.6

.9

.0

.5

.1

.2

.1

.7

.7

.9

.5

831.85

.0

.2

.4

.7

.3

.3

.9

.1

.5

.4

.0

.2

.4

.1

.4

.8

.4

.4

839.59

839.70

.8

.8

.8

.8

.8

6.

837.00

.6

.6

834.46

834.38

.8

.8

831.98

832.11

832.48

832.31

833.13833.16

834.96

834.88

837.28

837.43

836.31

836.21

.8

.8

.1

834.53

835.67

837.41

835.01

833.21

832.46

832.08

.3

6.

.4

.6

7.

7.

.6

.6

9.

9.

839.60

.9

0.

0.

9.

9.

9.

838.60838.39

833.78

833.76

833.70

833.72

837.29 837.34

839.71

839.75

839.71 839.69

838.26

838.19

839.54

839.50

839.82839.88

.7

839.63 839.50

836.35

837.23

834.46

830.83

829.94

830.15

830.69

832.51

831.67

832.13

835.35

832.11

831.57

833.04

833.34

840.43

843.38

837.55

839.51

838.19

834.82

836.97

836.68

835.33

838.07

832.53

9.

835.96

840.49

839.64

840.00

839.35

839.81

839.39

839.98

837.95

840.13

839.49

840.28

839.88

839.21

835.79

832.16

832.38

837 838 839 841

837838839

838.94

APPROXIMATE BOUNDARY LINE

APPROXIMATE BOUNDARY LINE

APPROXIMATE SECTION LINE

APPROXIMATE R/W

APPROXIMATE R/W

839.13

.9

.0

.7

.9

.5

.5

.1

.2

.9

.5

.3

.4

.0

.6

.7

.2

.5

.2

.5

838.73

838.82

.0

.1

.8

.1

.0

.5

BUILDING 128

TRANSFORMER VAULT

(BRICK)

FFE:842.33

NOTICE NO

WEAPONS SIGN

SEE TITLE 18 USC 903 AND

TITLE 38CFR 1.218 SIGN

BASEMENT ACCESS

TOP OF CURB CUT TO

ACCOMMODATE GATE

BACK OF CURB CUT TO

ACCOMMODATE GATE

GATE

GATE

4' CHAIN LINK FENCE

6' METAL FENCE

GATE

GATE

3"x3" POST, 3' TALL

NO PARKING ANYTIME SIGN

NO PARKING ANYTIME SIGN

NO PARKING ANYTIME SIGN

NO PARKING ANYTIME SIGN

NO PARKING ANYTIME SIGN

SIGN POST

YIELD

SIGN

STEPS

STEPS

STEPS

STEPS

STEPS

STEPS

NOTICE

NO FIREARMS

OR WEAPONS

ALLOWED ON

THIS PROPERTY

SIGN

MULCH

15'30' 30'

SCALE 1" = 30'

Topographic Survey

SCALE: 1" = 30'NORTH

FLAG POLE

I

L

PM

RWM

W

YD

SQUARE/RECTANGULAR STORM INLETCBWATER CURB STOP

W

CS

COMMUNICATION UTILITIES VAULTC

COMMUNICATION BOXC

COMMUNICATION UTILITIES PEDESTALC

PED

COMMUNICATION UTILITIES MANHOLEC

GAS METERG

GAS VALVE (TYP.)

G

WATER METERW

WATER VALVE (TYP.)

W

FIRE HYDRANT

POST INDICATOR VALVEPIV

IRRIGATION CONTROL VALVEICV

YARD HYDRANTYH

WATER UTILITIES MANHOLEW

POWER POLE/ UTILITY POLE

LIGHT POLELP

TRANSFORMER PADTP

ELECTRICAL BOXEB

ELECTRICAL METERM

GUY ANCHOR

ELECTRICAL UTILITIES MANHOLEE

ELECTRICAL PANELPP

ELECTRIC UTILITIES VAULTE

YARD LIGHTYL

STORM DRAINAGE MANHOLED

ROUND STORM DRAINAGE INLETCB

SANITARY SEWER MANHOLES

CLEANOUTCO

DECIDUOUS TREE

CONIFEROUS TREE

BUSH (DECIDUOUS)

BUSH (CONIFEROUS)

BOULDER

HORIZONTAL CONTROL POINTHC

BENCHMARK

BOUNDARY MONUMENTIP

OVERHEAD UTILITY- MULTIPLE SVCS. (EXST.)OHU

DOWNSPOUTDS

FINISHED FLOOR ELEVATION

BOLLARDB

MAILBOXMB

SINGLE-POST SIGN

DOUBLE-POST SIGN

CONCRETE MATERIAL

PAVEMENT MATERIAL

GRAVEL/STONE MATERIAL

BUILDING (ENCLOSED)

SAN: SANITARY SEWER (EXST.)

STM: STORM SEWER (EXST.)

OVERHEAD ELECTRIC LINE (EXST.)OE

UNDERGROUND ELECTRIC LINE (EXST.)UE

OVERHEAD TELECOM/DATA LINE (EXST.)OC

UNDERGROUND TELECOM/DATA LINE (EXST.)UC

UNDERGROUND FIBER OPTIC LINE (EXST.)FO

GAS LINE (EXST.)G

WATER LINE (EXST.)W

HAND RAILo o

FENCE LINE (TYP.)[] []

CHAIN-LINK FENCE LINEx x

EDGE OF LANDSCAPING

BUILDING (OPEN-AIR CANOPY)

GAS CURB STOP

ELETRICAL HANDHOLE

IRRIGATION SIDEWALK CROSSING

LIFT STATION MANHOLE

MONITORING WELL

PARKING BLOCK

PARKING METER

RIGHT OF WAY MARKER

SOIL BORING

LAWN SPRINKLER HEAD

GAS UTILITIES VAULT

WATER UTILITIES VAULT

WATER LEVEL

WELL

YARD DRAIN

AIR CONDITIONING UNIT

ADA DOOR BUTTON

FLAGPOLE

ELECTRIC UTILITIES PEDESTALE

PED POST/FENCE GATE

ADA SYMBOLBURIED LINE - WARNING RISER!

TRAFFIC UTILITIES MANHOLE/HAND HOLETF

TRAFFIC UTILITIES VAULTTF

STRAIN POLESP

TRAFFIC CONTROLS CABINET/ PEDESTALTF

PED

G

CS

G

AC

H

W

UU

UNDERGROUND FIBER OPTIC LINE (RECORD)FO

UNDERGROUND UTILITY- MULTIPLE SVCS. (EXST.)UU

OVERHEAD FIBER OPTIC LINE (EXST.)OFO

OFO

OVERHEAD TRAFFIC CONTROL LINE (EXST.)OTR

OTR

UNDERGROUND TRAFFIC CONTROL LINE (EXST.)UTR

FARM FIELD TYPE FENCE

GUARDRAIL

SANITARY SEWER (RECORD)SS

WATER LINE (RECORD)W

STORM SEWER (RECORD)ST

GAS LINE (RECORD)G

UNDERGROUND PRIMARY ELECTRIC LINE (EXST.)PE

UNDERGROUND PRIMARY ELECTRIC LINE (RECORD)PE

UNDERGROUND ELECTRIC LINE (RECORD)UE

UNDERGROUND TELECOM/DATA LINE (RECORD)UC

UNDERGROUND UTILITY- MULTIPLE SVCS. (RECORD)

OVERHEAD FIBER OPTIC LINE (RECORD)

OVERHEAD TRAFFIC CONTROL LINE (RECORD)

UNDERGROUND TRAFFIC CONTROL LINE (RECORD)UTR

IRRIGATION LINE (EXST.)IRR

IRRIGATION LINE (RECORD)IRR

OVERHEAD ELECTRIC LINE (RECORD)OE

OVERHEAD UTILITY- MULTIPLE SVCS. (RECORD)OHU

OVERHEAD TELECOM/DATA LINE (RECORD.)OC

CHILLED WATER LINE (EXST.)CW

CHILLED WATER LINE (RECORD)CW

HOT WATER LINE (EXST.)HW

HOT WATER LINE (RECORD)HW

TUNNEL (RECORD)

TUNNEL (EXST.)

SS SANITARY SEWER (EXST.)

ST STORM SEWER (EXST.)

STEAM LINE (EXST.)STEAM

STEAM LINE (RECORD)STEAM

M A

T C

H L

IN

E

S

E E

S H

E E

T C

.2

T

MATCHLINE: SEE SHEET C0.3T

M A

T C

H L

IN

E

S

E E

S H

E E

T C

.9

T

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

CONSTRUCTION

DOCUMENT

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

Viridian Architectural Design, Inc.

2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46808

PH: 260.424.4830

www.viridian-design.net

Civil Engineering:

Improve Sewer System and Water Loop

Marion, Indiana

610-21-104

Campus Project Director

06 / 15 / 2023Revisions: Date:

VIRIDIAN

ARCHITECTURAL DESIGN INC.

Engineering Resources, Inc.

4175 New Vision Dr., Fort Wayne, IN 46845

PH: 260-490-1025

Website: ericonsulting

All concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural Design Inc. and shall not be used for any purpose without prior expressed written consent. The Contracting Officer Representative shall be permitted to retain copies for information and reference.

OF 85

NOTE: THE SURVEY DEPICTED ON THIS DRAWING WAS PUBLISHED ON THE DATE CERTIFIED ABOVE AND, THEREFORE, ANY MODIFICATIONS MADE TO THE SITE AFTER THIS DATE ARE NOT CERTIFIED BY BERTSCH-FRANK & ASSOCIATES.

8707 / 31 / 2023

1. THIS SURVEY WAS PERFORMED FOR THE EXPRESS PURPOSE OF MAPPING THE EXISTING TOPOGRAPHIC FEATURES FOR THE

2. THE UNDERGROUND UTILITY INFORMATION REPRESENTED ON THIS DRAWING WAS DELINEATED USING RECORD INFORMATION, BY FIELD MEASUREMENTS OF VISUAL APPURTENANCES, AND BY A SITE UTILITY-LOCATION SURVEY CONDUCTED BY MASON

PRIVATE LOCATING, (888) 316-3933. ADDITIONAL UNDERGROUND UTILITIES MAY EXIST, THE LOCATIONS OF WHICH WERE NOT DETERMINED AT THE TIME OF THIS SURVEY. ALL UTILITY LOCATIONS ARE APPROXIMATE ONLY.

3. THE LOCATIONS AND DIMENSIONS OF ALL BUILDING STRUCTURES ON THE FACE OF THIS SURVEY ARE APPROXIMATED FOR REFERENCE ONLY. BUILDING DIMENSIONS ARE NOT INTENDED TO BE SCALED FOR STRUCTURAL DETAILING/ DESIGN.

4. THE HORIZONTAL COORDINATES REPRESENTED HEREIN ARE PROJECTED TO NGS NAD 83, INDIANA STATE PLANE EAST. VERTICAL COORDINATES REPRESENTED HEREIN ARE PROJECTED TO NAVD 88. SEE SHEET C0.0 FOR VERTICAL AND HORIZONTAL CONTROL

POINT DESCRIPTIONS.

5. THE DELINEATION OF WETLANDS OR OTHER ENVIRONMENTAL CONDITIONS WERE NOT CONSIDERED AS A PART OF THIS SURVEY.

6. THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RE-TRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY

OR A SURVEYOR LOCATION REPORT.

GENERAL NOTES:

CERTIFICATION:

THE UNDERSIGNED LAND SURVEYOR, REGISTERED UNDER THE LAWS OF THE STATE OF INDIANA, HEREBY CERTIFIES THAT HE HAS MADE A TOPOGRAPHICAL AND UTILITY SURVEY OF THE AREA DEPICTED. I HEREBY CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF THAT THIS PLAT REPRESENTS A TOPOGRAPHIC AND UTILITY SURVEY CONDUCTED UNDER MY DIRECT SUPERVISION.

PROJECT NO.: 21093.100

SURVEYED FOR: VIRIDIAN ARCHITECTURAL DESIGN

DATE(S) OF FIELDWORK: MARCH 23, 2021 - MAY 5, 2021

IN WITNESS THEREOF, I HEREUNTO PLACE MY

HAND AND SEAL THIS 10th DAY OF MAY, 2021.

ROSS M. FRANK

INDIANA REGISTERED LAND SURVEYOR NO. 20500021

LP

LP

CO

C

G

TP

TP

E

D

S

S

S

CB

D

S

D

S

D

S

S

CB

HC

HC

HC

HC

C

PED

E

W

CB

D

CB

S T E A M

S T E A M

S T E A M

C

PED

D

S

E

S

S

S

D

S

D

CB

D

CB

D

CB

S

S

E

CB

HC

EB

C

PED

C

PED

MB

W

MBMBMB

C

PED

C

PED

MB

W

MB

W

W

CB

CB

S

CB

CB

CB

DCBCB

CBCBCB

D

CB

CB

S

CB

CB

CB

CBCBCB

CBCB

CB

DD

IP IP

CB

CB

CB

D

D

S

S

E

LP

LP

CBCB

SAN:8" PVC

SA

N :8

PV

C

SAN:8" PVC

SAN:6" PVC

SAN:6" PVC SAN:12" DIP

SAN:12" DIP

S A N :6

D

IP

SA

N :6

PV

C

EOI

WATER LINE STUBBED

& ABANDONED

10" PER RECORD

SAN:15" VCP

VINE ROAD

PARK DRIVE

D

IX

R O

A D

VINE ROAD

E 38th STREET

E 38th STREET

G E

O R

G

IA

S T

R E

E T

SAN - 390047

Manhole Rim. Elev.=834.37 Inv. 829.67, 8" PVC~SW.

Inv. 829.57, 8" PVC~NE.

SAN - 390049

Manhole

Rim. Elev.=837.06 Inv. 828.81, 8" PVC~SW.

Inv. 830.24, 6" PVC~NW.

Inv. 828.76, 8" PVC~E.

SAN - 390050

Manhole Rim. Elev.=834.37 Inv. 830.97, 6" PVC~W.

Inv. 830.77, 6" PVC~SE.

SAN - 395002

Manhole Rim. Elev.=831.11 Inv. 827.91, 12" DIP~W.

Inv. 827.87, 12" DIP~SE.

SAN - 395004

Manhole Rim. Elev.=832.59 Inv. 827.19, 12" DIP~NW.

Inv. 827.94, 6" DIP~NE.

Inv. 827.14, 12" DIP~SE.

SAN - 395006

Manhole

Rim. Elev.=838.04 Inv. 836.54, 6" VCP~NE.

Inv. 832.04, 6" DIP~SE.

Inv. 832.01, 6" DIP~SW.

SAN - 395007

Manhole

Rim. Elev.=840.19 Inv. 832.24, 6" PVC~SE.

Inv. 832.29, 6" PVC~NW.

Inv. 832.19, 6" PVC~SW.

APPROXIMATE LOCATION OF ELECTRIC

MANHOLE #14 (NOT FOUND)

APPROXIMATE LOCATION

OF ELECTRIC MANHOLE

#15 (NOT FOUND)

APPROXIMATE LOCATION OF

TRANSFORMER #79V1274 (NOT

FOUND)

ELECTRIC MANHOLE #16

TRANSFORMER

#79V1275

ELECTRIC

MANHOLE #18

ELECTRIC MANHOLE #19

APPROXIMATE LOCATION OF

COMMUNICATION VAULT #53

(NOT FOUND)

COMMUNICATION LINES

FOR PREVIOUSLY

DEMOLISHED BUILDINGS

HYDRANT #30

BUILDING 32

SINGLE QUARTERS

BUILDING 91

1-CAR GARAGE

BUILDING 125

2-CAR GARAGE

BUILDING 33

DUPLEX QUARTERS

APPROXIMATE LOCATION OF SANITARY

MANHOLE PER RECORD (NOT FOUND)

APPROXIMATE LOCATION OF STORM

MANHOLE PER RECORD (NOT FOUND)

APPROXIMATE

LOCATION OF STORM

MANHOLE PER

RECORD (NOT FOUND)

APPROXIMATE BOUNDARY LINE

APPROXIMATE BOUNDARY LINE

APPROXIMATE SECTION LINE

APPROXIMATE R/W

APPROXIMATE R/W

SAN - 395078

Manhole

Rim. Elev.=838.58 Inv. 830.58, 15" VCP~E.

Inv. 830.48, 15" VCP~W.

SAN - 395091

Manhole

Rim. Elev.=838.19 Inv. 829.39, 15" VCP~E.

Inv. 829.19, 15" VCP~W.

SAN:15" VCP

SAN:15" VCP

S T M

:2

V C

P

V C

P

ST

M :1

0" V

C P

STM:24" VCP

S T M

:6 " P

V C

STM:24" V

CP

STM:6" VCP

STM:12" VCP

STM:15" RCPSTM:15" RCP

S T M

:1

R C

P

S T M

: 1

R C

P

S T M

:1

P V C

STM:15" RCP

15" RCP

STM

:12" RCP

S

TM

:1 2"

R C P

STM:72" RCP

STM:72" RCP

STM:72" RCP

S T M

:2

R C

P

STM - 390046

Manhole

Rim. Elev.=833.98 Inv. 829.93, 18" VCP~N.

Inv. 830.13, 12" VCP~E.

Inv. 829.90, 12" VCP~S.

Inv. 829.83, 12" VCP~SW.

Inv. 830.18, 10" VCP~S.

Inv. 830.09, 10" VCP~S.

Inv. 830.00, 4" VCP~E.

Inv. 828.68, 18" VCP~W.

STM - 395003

Manhole Rim. Elev.=832.40 Inv. 827.90, 8" VCP~S.

Inv. 829.20, 6" VCP~SW.

Inv. 826.18, 10" VCP~NE.

Inv. 825.10, 24" VCP~NW.

Inv. 825.10, 24" VCP~SE.

STM - 395005

Manhole

Rim. Elev.=833.08 Inv. 826.48, 18" VCP~NW.

Inv. 827.58, 6" VCP~NE.

Inv. 826.48, 18" VCP~SE.

STM - 391007

Curb Cast Inlet Rim. Elev.=836.96 Inv. 834.71, 6" PVC~E.

STM - 391012

Manhole

Rim. Elev.=835.64 Inv. 830.14, 6" VCP~S.

Inv. 825.84, 24" VCP~S.

Inv. 825.94, 24" VCP~NE.

STM - 391013

Inlet Rim. Elev.=832.11 Inv. 830.81, 6" VCP~W.

STM - 395001

Manhole Rim. Elev.=833.36 Inv. 825.61, 24" VCP~SW.

Inv. 826.51, 12" VCP~NW.

Inv. 825.56, 24" VCP~SE.

STM - 395008

Curb Cast Inlet

Rim. Elev.=831.62 Inv. 830.17, 6" VCP~NE.

STM - 395049

Round Inlet

Filled in with Soil Rim. Elev.=835.04

BTM Soil 833.29

STM - 395079

Curb Cast Inlet

Rim. Elev.=837.84 Inv. 834.54, 12" RCP~NE.

Inv. 834.49, 15" RCP~W.

STM - 395080

Curb Cast Inlet Rim. Elev.=836.28 Inv. 833.08, 15" RCP~E.

Inv. 833.38, 12" RCP~N.

Inv. 833.03, 15" RCP~W.

STM - 395081

Curb Cast Inlet

Rim. Elev.=836.79 Inv. 833.64, 12" RCP~S.

STM - 395085

Curb Cast Inlet Rim. Elev.=835.68 Inv. 832.43, 12" RCP~W.

STM - 395086

Curb Cast Inlet Rim. Elev.=835.61 Inv. 832.31, 12" RCP~E.

Inv. 832.26, 12" RCP~W.

Inv. 832.16, 12" RCP~S.

STM - 395087

Curb Cast Inlet

Rim. Elev.=835.68 Inv. 832.48, 12" RCP~E.

STM - 395083

Curb Cast Inlet Rim. Elev.=835.66 Inv. 831.86, 12" RCP~N.

Inv. 831.76, 12" RCP~W.

Inv. 831.81, 15" RCP~SW.

STM - 395084

Curb Cast Inlet

Rim. Elev.=835.65 Inv. 832.10, 12" RCP~E.

STM - 395089

Curb Cast Inlet

Rim. Elev.=837.44 Inv. 834.99, 12" HDPE~N.

Inv. 833.94, 10" PVC~S.

STM - 390052

Manhole

Rim. Elev.=833.09 Inv. 824.59, 12" RCP~SW.

STM - 391006

Round Inlet Rim. Elev.=839.01 Inv. 832.31, 15" RCP~E.

Inv. 832.01, 15" RCP~W.

Inv. 832.51, 12" RCP~SE.

Inv. 832.46, 12" RCP~SW.

Inv. 815.81, 12" VCP Straight Down~N.

STM - 391005

Curb Cast Inlet Rim. Elev.=837.77 Inv. 834.67, 6" HDPE~S.

Inv. 834.72, 6" HDPE~SE.

Inv. 834.22, 12" RCP~NW.

STM - 395090

Curb Cast Inlet Rim. Elev.=837.25 Inv. 834.10, 10" PVC~N.

Inv. 833.65, 15" RCP~W. STM - 395088

Manhole Rim. Elev.=836.27

Inv. 815.07, 72" RCP~W.

Inv. 831.42, 15" RCP~E.

Inv. 831.32, 15" RCP~NE.

Inv. 815.07, 72" RCP~E.

STM - 395082

Manhole Rim. Elev.=838.78 Inv. 814.93, 72" RCP~W.

Inv. 814.83, 72" RCP~E.

STM - 1392016

Round Inlet

Rim. Elev.=839.79 Inv. 830.59, 10" VCP~W.

Inv. 830.59, 12" PVC~E.

Inv. 836.74, 6" PVC~SW.

Inv. 834.84, 6" HDPE~SW.

STM - 1392051

Round Inlet Rim. Elev.=838.81 Inv. 823.11, 24" RCP~S.

Inv. 823.11, 24" RCP~N.

FLAG POLE

I

L

PM

RWM

W

YD

SQUARE/RECTANGULAR STORM INLETCBWATER CURB STOP

W

CS

COMMUNICATION UTILITIES VAULTC

COMMUNICATION BOXC

COMMUNICATION UTILITIES PEDESTALC

PED

COMMUNICATION UTILITIES MANHOLEC

GAS METERG

GAS VALVE (TYP.)

G

WATER METERW

WATER VALVE (TYP.)

W

FIRE HYDRANT

POST INDICATOR VALVEPIV

IRRIGATION CONTROL VALVEICV

YARD HYDRANTYH

WATER UTILITIES MANHOLEW

POWER POLE/ UTILITY POLE

LIGHT POLELP

TRANSFORMER PADTP

ELECTRICAL BOXEB

ELECTRICAL METERM

GUY ANCHOR

ELECTRICAL UTILITIES MANHOLEE

ELECTRICAL PANELPP

ELECTRIC UTILITIES VAULTE

YARD LIGHTYL

STORM DRAINAGE MANHOLED

ROUND STORM DRAINAGE INLETCB

SANITARY SEWER MANHOLES

CLEANOUTCO

DECIDUOUS TREE

CONIFEROUS TREE

BUSH (DECIDUOUS)

BUSH (CONIFEROUS)

BOULDER

HORIZONTAL CONTROL POINTHC

BENCHMARK

BOUNDARY MONUMENTIP

OVERHEAD UTILITY- MULTIPLE SVCS. (EXST.)OHU

DOWNSPOUTDS

FINISHED FLOOR ELEVATION

BOLLARDB

MAILBOXMB

SINGLE-POST SIGN

DOUBLE-POST SIGN

CONCRETE MATERIAL

PAVEMENT MATERIAL

GRAVEL/STONE MATERIAL

BUILDING (ENCLOSED)

SAN: SANITARY SEWER (EXST.)

STM: STORM SEWER (EXST.)

OVERHEAD ELECTRIC LINE (EXST.)OE

UNDERGROUND ELECTRIC LINE (EXST.)UE

OVERHEAD TELECOM/DATA LINE (EXST.)OC

UNDERGROUND TELECOM/DATA LINE (EXST.)UC

UNDERGROUND FIBER OPTIC LINE (EXST.)FO

GAS LINE (EXST.)G

WATER LINE (EXST.)W

HAND RAILo o

FENCE LINE (TYP.)[] []

CHAIN-LINK FENCE LINEx x

EDGE OF LANDSCAPING

BUILDING (OPEN-AIR CANOPY)

GAS CURB STOP

ELETRICAL HANDHOLE

IRRIGATION SIDEWALK CROSSING

LIFT STATION MANHOLE

MONITORING WELL

PARKING BLOCK

PARKING METER

RIGHT OF WAY MARKER

SOIL BORING

LAWN SPRINKLER HEAD

GAS UTILITIES VAULT

WATER UTILITIES VAULT

WATER LEVEL

WELL

YARD DRAIN

AIR CONDITIONING UNIT

ADA DOOR BUTTON

FLAGPOLE

ELECTRIC UTILITIES PEDESTALE

PED POST/FENCE GATE

ADA SYMBOLBURIED LINE - WARNING RISER!

TRAFFIC UTILITIES MANHOLE/HAND HOLETF

TRAFFIC UTILITIES VAULTTF

STRAIN POLESP

TRAFFIC CONTROLS CABINET/ PEDESTALTF

PED

G

CS

G

AC

H

W

UU

UNDERGROUND FIBER OPTIC LINE (RECORD)FO

UNDERGROUND UTILITY- MULTIPLE SVCS. (EXST.)UU

OVERHEAD FIBER OPTIC LINE (EXST.)OFO

OFO

OVERHEAD TRAFFIC CONTROL LINE (EXST.)OTR

OTR

UNDERGROUND TRAFFIC CONTROL LINE (EXST.)UTR

FARM FIELD TYPE FENCE

GUARDRAIL

SANITARY SEWER (RECORD)SS

WATER LINE (RECORD)W

STORM SEWER (RECORD)ST

GAS LINE (RECORD)G

UNDERGROUND PRIMARY ELECTRIC LINE (EXST.)PE

UNDERGROUND PRIMARY ELECTRIC LINE (RECORD)PE

UNDERGROUND ELECTRIC LINE (RECORD)UE

UNDERGROUND TELECOM/DATA LINE (RECORD)UC

UNDERGROUND UTILITY- MULTIPLE SVCS. (RECORD)

OVERHEAD FIBER OPTIC LINE (RECORD)

OVERHEAD TRAFFIC CONTROL LINE (RECORD)

UNDERGROUND TRAFFIC CONTROL LINE (RECORD)UTR

IRRIGATION LINE (EXST.)IRR

IRRIGATION LINE (RECORD)IRR

OVERHEAD ELECTRIC LINE (RECORD)OE

OVERHEAD UTILITY- MULTIPLE SVCS. (RECORD)OHU

OVERHEAD TELECOM/DATA LINE (RECORD.)OC

CHILLED WATER LINE (EXST.)CW

CHILLED WATER LINE (RECORD)CW

HOT WATER LINE (EXST.)HW

HOT WATER LINE (RECORD)HW

TUNNEL (RECORD)

TUNNEL (EXST.)

SS SANITARY SEWER (EXST.)

ST STORM SEWER (EXST.)

STEAM LINE (EXST.)STEAM

STEAM LINE (RECORD)STEAM

M A

T C

H L

IN

E

S

E E

S H

E E

T C

.2

U

MATCHLINE: SEE SHEET C0.3U

15'30' 30'

SCALE 1" = 30'

Utility Survey

SCALE: 1" = 30'NORTH

M A

T C

H L

IN

E

S

E E

S H

E E

T C

.9

U

NOTE: THE SURVEY DEPICTED ON THIS DRAWING WAS PUBLISHED ON THE DATE CERTIFIED ABOVE AND, THEREFORE, ANY MODIFICATIONS MADE TO THE SITE AFTER THIS DATE ARE NOT CERTIFIED BY BERTSCH-FRANK & ASSOCIATES.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

CONSTRUCTION

DOCUMENT

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

Viridian Architectural Design, Inc.

2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46808

PH: 260.424.4830

www.viridian-design.net

Civil Engineering:

Improve Sewer System and Water Loop

Marion, Indiana

610-21-104

Campus Project Director

06 / 15 / 2023Revisions: Date:

VIRIDIAN

ARCHITECTURAL DESIGN INC.

Engineering Resources, Inc.

4175 New Vision Dr., Fort Wayne, IN 46845

PH: 260-490-1025

Website: ericonsulting

All concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural Design Inc. and shall not be used for any purpose without prior expressed written consent. The Contracting Officer Representative shall be permitted to retain copies for information and

OF 858707 / 31 / 2023

1. THIS SURVEY WAS PERFORMED FOR THE EXPRESS PURPOSE OF MAPPING THE EXISTING TOPOGRAPHIC FEATURES FOR THE

2. THE UNDERGROUND UTILITY INFORMATION REPRESENTED ON THIS DRAWING WAS DELINEATED USING RECORD INFORMATION, BY FIELD MEASUREMENTS OF VISUAL APPURTENANCES, AND BY A SITE UTILITY-LOCATION SURVEY CONDUCTED BY MASON

PRIVATE LOCATING, (888) 316-3933. ADDITIONAL UNDERGROUND UTILITIES MAY EXIST, THE LOCATIONS OF WHICH WERE NOT DETERMINED AT THE TIME OF THIS SURVEY. ALL UTILITY LOCATIONS ARE APPROXIMATE ONLY.

3. THE LOCATIONS AND DIMENSIONS OF ALL BUILDING STRUCTURES ON THE FACE OF THIS SURVEY ARE APPROXIMATED FOR REFERENCE ONLY. BUILDING DIMENSIONS ARE NOT INTENDED TO BE SCALED FOR STRUCTURAL DETAILING/ DESIGN.

4. THE HORIZONTAL COORDINATES REPRESENTED HEREIN ARE PROJECTED TO NGS NAD 83, INDIANA STATE PLANE EAST. VERTICAL COORDINATES REPRESENTED HEREIN ARE PROJECTED TO NAVD 88. SEE SHEET C0.0 FOR VERTICAL AND HORIZONTAL CONTROL

POINT DESCRIPTIONS.

5. THE DELINEATION OF WETLANDS OR OTHER ENVIRONMENTAL CONDITIONS WERE NOT CONSIDERED AS A PART OF THIS SURVEY.

6. THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RE-TRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY

OR A SURVEYOR LOCATION REPORT.

GENERAL NOTES:

CERTIFICATION:

THE UNDERSIGNED LAND SURVEYOR, REGISTERED UNDER THE LAWS OF THE STATE OF INDIANA, HEREBY CERTIFIES THAT HE HAS MADE A TOPOGRAPHICAL AND UTILITY SURVEY OF THE AREA DEPICTED. I HEREBY CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF THAT THIS PLAT REPRESENTS A TOPOGRAPHIC AND UTILITY SURVEY CONDUCTED UNDER MY DIRECT SUPERVISION.

PROJECT NO.: 21093.100

SURVEYED FOR: VIRIDIAN ARCHITECTURAL DESIGN

DATE(S) OF FIELDWORK: MARCH 23, 2021 - MAY 5, 2021

IN WITNESS THEREOF, I HEREUNTO PLACE MY

HAND AND SEAL THIS 10th DAY OF MAY, 2021.

ROSS M. FRANK

INDIANA REGISTERED LAND SURVEYOR NO. 20500021

HC

S

HC

W

W

W

FLAG POLE

FLAG POLE

FLAG POLE

FLAG POLE

FLAG POLE

W

COCO

W W

CEB

TP

W

D

S

CB

M

CB

CB

S

D

CB

CB

S

W

CB

S

C

PED

C

PED

MBMB

W

WW

MBMB

WC

PED

C

PED

W

MBMBMB

W

W

CS

W

MB

W

D

S

D

S S

C

S

D

D

S

S

S

KUDER PLACE

HYD

E

RO

AD

IR

W

IN

D

R

IV

E

E 38th STREET

S B

LA

IR

S T

R E

E T

BM#7312

HCV#37012

HCV#31010

E 38th STREET

PARK

DRIVE

BUILDING 3002

LOWER BARN

BUILDING 4801

COMMITTAL SHELTER

841.12 840.87 839.67 838.58 837.41 835.93 833.94 831.82 829.48 827.38 824.77

841.14 840.73 839.60 838.52 837.49 836.11 834.38 831.26 829.06

829.04

826.43 824.60826.45

841.34

841.34 840.94 839.88 838.75 837.69 836.21 834.17 832.00 825.02827.59829.76

841.75 841.63

841.56 840.72

839.34 839.30

839.09

839.16 838.52

838.51 837.60 837.64

837.11 837.36

.9

.1

826.07

826.50

840.73

839.70 838.74

837.48

836.12 834.19

.2

.2

.2

.9

840.57

839.97 839.72 839.01 838.04

835.57

831.73 825.42

824.44 836.16

837.15 838.40

840.71 841.00

839.20

.1

.8

824.99

824.69 826.57826.27

828.15

828.14 8 .7

.5

826.36825.98

.5

.1

.8

.5

.8

.5

837.01

834.13 836.77

834.74

0.

.9

.6

.4

.5

.8

3.

1.

824.98

826.02

828.77

833.50

838.53

837.01

838.09

837.57

838.78

839.04

837.71

839.25

.6

.9

.3

.3

838.96

840.50

.7

840.44 840.22

839.90

839.71

839.54

841.29

825830

835840

836837838839841

831832833

836840

8278288

APPROXIMATE BOUNDARY LINE

APPROXIMATE BOUNDARY LINE

APPROXIMATE BOUNDARY LINE

APPROXIMATE R/W

APPROXIMATE R/W

MARION NATIONAL CEMETERY

MARION

NATIONAL

CEMETERY

MARION

NATIONAL

CEMETERY

MARION NATIONAL CEMETERY

MARION NATIONAL CEMETERY

6' VINYL FENCE

GATE

8' BRICK PILLARS

6' PRIVACY FENCE

MULCH LANDSCAPING

MULCH LANDSCAPING

MULCH LANDSCAPING

MULCH LANDSCAPING

MULCH LANDSCAPING

MULCH LANDSCAPING

6"x6" HYDE ROAD POST

6"X6" KUDER PL/HYDE RD POST

SECTION 9

STONE POST

SECTION 10

STONE POST

SECTION 10 STONE POST

SECTION 11 STONE POST BLUE STAR

MEMORIAL SIGN

REGISTER OF HISTORIC

PLACES SIGN

DEDICATION SIGN

NO FIREARMS ALLOWED

ON THIS PROPERTY SIGN

STOP

SIGN

ADDRESS BY

PRESIDENT

LINCOLN SIGN

DIRECTIONAL SIGN

FOR BURIAL

SECTIONS

DO NOT ENTER SIGN

LEFT TURN ONLY SIGN

DO NOT

ENTER SIGN

RIGHT TURN ONLY SIGN

SPEED LIMIT 20 MPH SIGN

12"x12" CONCRETE POST

BIVOUAC OF THE DEAD

VERSE TABLETS

8' BRICK PILLARS

WOODS

6' METAL FENCE

MARION NATIONAL CEMETERY BRICK SIGN

OVERHEAD SUPPORT CABLE

OVERHEAD SUPPORT CABLE

38TH ST/BLAIR ST SIGN

RAILROAD CROSSING SIGN

STEPS WITH HANDRAIL STEPS

MARION NATIONAL CEMETERY

15'30' 30'

SCALE 1" = 30'

Topographic Survey

SCALE: 1" = 30'NORTH

FLAG POLE

I L

PM

RWM

W

YD

SQUARE/RECTANGULAR STORM INLETCB

WATER CURB STOP

W

CS

COMMUNICATION UTILITIES VAULTC

COMMUNICATION BOXC

COMMUNICATION UTILITIES PEDESTALC

PED

COMMUNICATION UTILITIES MANHOLEC

GAS METERG

GAS VALVE (TYP.)

G

WATER METERW

WATER VALVE (TYP.)

W

FIRE HYDRANT

POST INDICATOR VALVEPIV

IRRIGATION CONTROL VALVEICV

YARD HYDRANTYH

WATER UTILITIES MANHOLEW

POWER POLE/ UTILITY POLE

LIGHT POLELP

TRANSFORMER PADTP

ELECTRICAL BOXEB

ELECTRICAL METERM

GUY ANCHOR

ELECTRICAL UTILITIES MANHOLEE

ELECTRICAL PANELPP

ELECTRIC UTILITIES VAULTE

YARD LIGHTYL

STORM DRAINAGE MANHOLED

ROUND STORM DRAINAGE INLETCB

SANITARY SEWER MANHOLES

CLEANOUTCO

DECIDUOUS TREE

CONIFEROUS TREE

BUSH (DECIDUOUS)

BUSH (CONIFEROUS)

BOULDER

HORIZONTAL CONTROL POINTHC

BENCHMARK

BOUNDARY MONUMENTIP

OVERHEAD UTILITY- MULTIPLE SVCS. (EXST.)OHU

DOWNSPOUTDS

FINISHED FLOOR ELEVATION

BOLLARDB

MAILBOXMB

SINGLE-POST SIGN

DOUBLE-POST SIGN

CONCRETE MATERIAL

PAVEMENT MATERIAL

GRAVEL/STONE MATERIAL

BUILDING (ENCLOSED)

SAN: SANITARY SEWER (EXST.)

STM: STORM SEWER (EXST.)

OVERHEAD ELECTRIC LINE (EXST.)OE

UNDERGROUND ELECTRIC LINE (EXST.)UE

OVERHEAD TELECOM/DATA LINE (EXST.)OC

UNDERGROUND TELECOM/DATA LINE (EXST.)UC

UNDERGROUND FIBER OPTIC LINE (EXST.)FO

GAS LINE (EXST.)G

WATER LINE (EXST.)W

HAND RAILo o

FENCE LINE (TYP.)[] []

CHAIN-LINK FENCE LINEx x

EDGE OF LANDSCAPING

BUILDING (OPEN-AIR CANOPY)

GAS CURB STOP

ELETRICAL HANDHOLE

IRRIGATION SIDEWALK CROSSING

LIFT STATION MANHOLE

MONITORING WELL

PARKING BLOCK

PARKING METER

RIGHT OF WAY MARKER

SOIL BORINGLAWN SPRINKLER HEAD

GAS UTILITIES VAULT

WATER UTILITIES VAULT

WATER LEVEL

WELL

YARD DRAIN

AIR CONDITIONING UNIT

ADA DOOR BUTTON

FLAGPOLE

ELECTRIC UTILITIES PEDESTALE

PED

POST/FENCE GATE

ADA SYMBOL

BURIED LINE - WARNING RISER!

TRAFFIC UTILITIES MANHOLE/HAND HOLETF

TRAFFIC UTILITIES VAULTTF

STRAIN POLESP

TRAFFIC CONTROLS CABINET/ PEDESTALTF

PED

G

CS

G

AC

H

W

UU

UNDERGROUND FIBER OPTIC LINE (RECORD)FO

UNDERGROUND UTILITY- MULTIPLE SVCS. (EXST.)UU

OVERHEAD FIBER OPTIC LINE (EXST.)OFO

OFO

OVERHEAD TRAFFIC CONTROL LINE (EXST.)OTR

OTR

UNDERGROUND TRAFFIC CONTROL LINE (EXST.)UTR

FARM FIELD TYPE FENCE

GUARDRAIL

SANITARY SEWER (RECORD)SS

WATER LINE (RECORD)W

STORM SEWER (RECORD)ST

GAS LINE (RECORD)G

UNDERGROUND PRIMARY ELECTRIC LINE (EXST.)PE

UNDERGROUND PRIMARY ELECTRIC LINE (RECORD)PE

UNDERGROUND ELECTRIC LINE (RECORD)UE

UNDERGROUND TELECOM/DATA LINE (RECORD)UC

UNDERGROUND UTILITY- MULTIPLE SVCS. (RECORD)

OVERHEAD FIBER OPTIC LINE (RECORD)

OVERHEAD TRAFFIC CONTROL LINE (RECORD)

UNDERGROUND TRAFFIC CONTROL LINE (RECORD)UTR

IRRIGATION LINE (EXST.)IRR

IRRIGATION LINE (RECORD)IRR

OVERHEAD ELECTRIC LINE (RECORD)OE

OVERHEAD UTILITY- MULTIPLE SVCS. (RECORD)OHU

OVERHEAD TELECOM/DATA LINE (RECORD.)OC

TUNNEL (RECORD)

TUNNEL (EXST.) CHILLED WATER LINE (EXST.)CW

CHILLED WATER LINE (RECORD)CW

HOT WATER LINE (EXST.)HW

HOT WATER LINE (RECORD)HW

SS SANITARY SEWER (EXST.)

ST STORM SEWER (EXST.)

STEAM LINE (EXST.)STEAM

STEAM LINE (RECORD)STEAM

M A

T C

H L

IN

E

S

E E

S H

E E

T C

.1

T

MATCHLINE: SEE SHEET C0.4T

NOTE: THE SURVEY DEPICTED ON THIS DRAWING WAS PUBLISHED ON THE DATE CERTIFIED ABOVE AND, THEREFORE, ANY MODIFICATIONS MADE TO THE SITE AFTER THIS DATE ARE NOT CERTIFIED BY BERTSCH-FRANK & ASSOCIATES.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

CONSTRUCTION

DOCUMENT

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

Viridian Architectural Design, Inc.

2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46808

PH: 260.424.4830

www.viridian-design.net

Civil Engineering:

Improve Sewer System and Water Loop

Marion, Indiana

610-21-104

Campus Project Director

06 / 15 / 2023Revisions: Date:

VIRIDIAN

ARCHITECTURAL DESIGN INC.

Engineering Resources, Inc.

4175 New Vision Dr., Fort Wayne, IN 46845

PH: 260-490-1025

Website: ericonsulting

All concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural Design Inc. and shall not be used for any purpose without prior expressed written consent. The Contracting Officer Representative shall be permitted to retain copies for information and

1. THIS SURVEY WAS PERFORMED FOR THE EXPRESS PURPOSE OF MAPPING THE EXISTING TOPOGRAPHIC FEATURES FOR THE

2. THE UNDERGROUND UTILITY INFORMATION REPRESENTED ON THIS DRAWING WAS DELINEATED USING RECORD INFORMATION, BY FIELD MEASUREMENTS OF VISUAL APPURTENANCES, AND BY A SITE UTILITY-LOCATION SURVEY CONDUCTED BY MASON

PRIVATE LOCATING, (888) 316-3933. ADDITIONAL UNDERGROUND UTILITIES MAY EXIST, THE LOCATIONS OF WHICH WERE NOT DETERMINED AT THE TIME OF THIS SURVEY. ALL UTILITY LOCATIONS ARE APPROXIMATE ONLY.

3. THE LOCATIONS AND DIMENSIONS OF ALL BUILDING STRUCTURES ON THE FACE OF THIS SURVEY ARE APPROXIMATED FOR REFERENCE ONLY. BUILDING DIMENSIONS ARE NOT INTENDED TO BE SCALED FOR STRUCTURAL DETAILING/ DESIGN.

4. THE HORIZONTAL COORDINATES REPRESENTED HEREIN ARE PROJECTED TO NGS NAD 83, INDIANA STATE PLANE EAST. VERTICAL COORDINATES REPRESENTED HEREIN ARE PROJECTED TO NAVD 88. SEE SHEET C0.0 FOR VERTICAL AND HORIZONTAL CONTROL

POINT DESCRIPTIONS.

5. THE DELINEATION OF WETLANDS OR OTHER ENVIRONMENTAL CONDITIONS WERE NOT CONSIDERED AS A PART OF THIS SURVEY.

6. THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RE-TRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY

OR A SURVEYOR LOCATION REPORT.

GENERAL NOTES:

CERTIFICATION:

THE UNDERSIGNED LAND SURVEYOR, REGISTERED UNDER THE LAWS OF THE STATE OF INDIANA, HEREBY CERTIFIES THAT HE HAS MADE A TOPOGRAPHICAL AND UTILITY SURVEY OF THE AREA DEPICTED. I HEREBY CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF THAT THIS PLAT REPRESENTS A TOPOGRAPHIC AND UTILITY SURVEY CONDUCTED UNDER MY DIRECT SUPERVISION.

PROJECT NO.: 21093.100

SURVEYED FOR: VIRIDIAN ARCHITECTURAL DESIGN

DATE(S) OF FIELDWORK: MARCH 23, 2021 - MAY 5, 2021

IN WITNESS THEREOF, I HEREUNTO PLACE MY

HAND AND SEAL THIS 10th DAY OF MAY, 2021.

ROSS M. FRANK

INDIANA REGISTERED LAND SURVEYOR NO. 20500021

HC

S

HC

W

W

W

FLAG POLE

FLAG POLE

FLAG POLE

FLAG POLE

FLAG POLE

W

COCO

W W

CEB

TP

W

D

S

CB

M

CB

CB

S

D

CB

CB

S

W

CB

S

C

PED

C

PED

MBMB

W

WW

MBMB

WC

PED

C

PED

W

MBMBMB

W

W

CS

W

MB

W

D

S

D

S S

C

S

D

D

S

S

S

S A N :1

2" D

IP

INV:829.23

CAPPED

SAN:10" RCP

KUDER PLACE

HYD

E

RO

AD

IR

W

IN

D

R

IV

E

E 38th STREET

S B

LA

IR

S T

R E

E T

E 38th STREET

PARK

DRIVE

SAN:8" VCP

SAN - 390004

Manhole

Rim. Elev.=837.43 Inv. 819.78, 12" DIP~S.

Inv. 819.68, 12" DIP~NE.

SAN - 395055

Manhole Rim. Elev.=826.02 Inv. 821.92, 4" VCP~S.

Inv. 820.72, 4" PVC~W.

Inv. 820.72, 4" PVC~E.

Inv. 820.72, 4" PVC~N.

SAN - 395077

Manhole

Rim. Elev.=841.05 Inv. 831.35, 10" PVC~N.

Inv. 832.75, 10" RCP~E.

Inv. 831.30, 15" VCP~W.

SAN - 395076

Manhole Rim. Elev.=840.72 Inv. 831.37, 8" VCP~E.

TRANSFORMER FOR WATER

AEP POLE #GR51-328

HAND HOLE FOR WATER SPIGOT

VALVE ABOVE GROUND

COMMUNICATION LINES

FOR PREVIOUSLY

DEMOLISHED BUILDINGS

BUILDING 3002

LOWER BARN

BUILDING 4801

COMMITTAL SHELTER

APPROXIMATE LOCATION OF

SANITARY MANHOLE

APPROXIMATE LOCATION OF

SANITARY LIFT STATION

APPROXIMATE BOUNDARY LINE

APPROXIMATE BOUNDARY LINE

APPROXIMATE BOUNDARY LINE

APPROXIMATE R/W

APPROXIMATE R/W

SAN - 395053

Manhole Rim. Elev.=824.09 Inv. 818.24, 12" VCP~SW.

Inv. 818.84, 6" PVC~E.

Inv. 818.19, 12" VCP~N.

S A N :1

2" V

C P

S A N

:1

V C

P

SAN:6" PVC

SAN - 395074

Manhole Rim. Elev.=837.50 Inv. 829.85, 8" VCP~W.

Inv. 829.80, 8" VCP~E.

SAN:8" VCP

S T M

:1

V C

P

S T M

:1

V C

P

STM:12" HDPE

STM:72" RCP

STM:72" RCP

STM - 390001

Manhole Rim. Elev.=825.79 Inv. 817.64, 12" VCP~S.

Inv. 817.47, 12" HDPE~E.

Inv. 817.41, 12" VCP~N.

STM - 390002

Curb Cast Inlet Rim. Elev.=823.96 Inv. 818.76, 12" HDPE~W.

STM - 390003

Curb Cast Inlet

Filled in with Soil Rim. Elev.=825.49

STM - 395054

Inlet

Rim. Elev.=827.07 Inv. 823.12, 12" PVC~W.

Inv. 823.02, 12" PVC~N.

STM - 390005

Manhole

Rim. Elev.=828.37 Inv. 813.12, 72" RCP~W.

Inv. 818.17, 12" PVC~S.

Inv. 810.17, 72" RCP~E.

STM - 395075

Manhole Rim. Elev.=839.87 Inv. 814.52, 72" RCP~W.

Inv. 814.47, 72" RCP~E.

M A

T C

H L

IN

E

S

E E

S H

E E

T C

.1

U

MATCHLINE: SEE SHEET C0.4U

15'30' 30'

SCALE 1" = 30'

Utility Survey

SCALE: 1" = 30'NORTH

FLAG POLE

I L

PM

RWM

W

YD

SQUARE/RECTANGULAR STORM INLETCB

WATER CURB STOP

W

CS

COMMUNICATION UTILITIES VAULTC

COMMUNICATION BOXC

COMMUNICATION UTILITIES PEDESTALC

PED

COMMUNICATION UTILITIES MANHOLEC

GAS METERG

GAS VALVE (TYP.)

G

WATER METERW

WATER VALVE (TYP.)

W

FIRE HYDRANT

POST INDICATOR VALVEPIV

IRRIGATION CONTROL VALVEICV

YARD HYDRANTYH

WATER UTILITIES MANHOLEW

POWER POLE/ UTILITY POLE

LIGHT POLELP

TRANSFORMER PADTP

ELECTRICAL BOXEB

ELECTRICAL METERM

GUY ANCHOR

ELECTRICAL UTILITIES MANHOLEE

ELECTRICAL PANELPP

ELECTRIC UTILITIES VAULTE

YARD LIGHTYL

STORM DRAINAGE MANHOLED

ROUND STORM DRAINAGE INLETCB

SANITARY SEWER MANHOLES

CLEANOUTCO

DECIDUOUS TREE

CONIFEROUS TREE

BUSH (DECIDUOUS)

BUSH (CONIFEROUS)

BOULDER

HORIZONTAL CONTROL POINTHC

BENCHMARK

BOUNDARY MONUMENTIP

OVERHEAD UTILITY- MULTIPLE SVCS. (EXST.)OHU

DOWNSPOUTDS

FINISHED FLOOR ELEVATION

BOLLARDB

MAILBOXMB

SINGLE-POST SIGN

DOUBLE-POST SIGN

CONCRETE MATERIAL

PAVEMENT MATERIAL

GRAVEL/STONE MATERIAL

BUILDING (ENCLOSED)

SAN: SANITARY SEWER (EXST.)

STM: STORM SEWER (EXST.)

OVERHEAD ELECTRIC LINE (EXST.)OE

UNDERGROUND ELECTRIC LINE (EXST.)UE

OVERHEAD TELECOM/DATA LINE (EXST.)OC

UNDERGROUND TELECOM/DATA LINE (EXST.)UC

UNDERGROUND FIBER OPTIC LINE (EXST.)FO

GAS LINE (EXST.)G

WATER LINE (EXST.)W

HAND RAILo o

FENCE LINE (TYP.)[] []

CHAIN-LINK FENCE LINEx x

EDGE OF LANDSCAPING

BUILDING (OPEN-AIR CANOPY)

GAS CURB STOP

ELETRICAL HANDHOLE

IRRIGATION SIDEWALK CROSSING

LIFT STATION MANHOLE

MONITORING WELL

PARKING BLOCK

PARKING METER

RIGHT OF WAY MARKER

SOIL BORINGLAWN SPRINKLER HEAD

GAS UTILITIES VAULT

WATER UTILITIES VAULT

WATER LEVEL

WELL

YARD DRAIN

AIR CONDITIONING UNIT

ADA DOOR BUTTON

FLAGPOLE

ELECTRIC UTILITIES PEDESTALE

PED

POST/FENCE GATE

ADA SYMBOL

BURIED LINE - WARNING RISER!

TRAFFIC UTILITIES MANHOLE/HAND HOLETF

TRAFFIC UTILITIES VAULTTF

STRAIN POLESP

TRAFFIC CONTROLS CABINET/ PEDESTALTF

PED

G

CS

G

AC

H

W

UU

UNDERGROUND FIBER OPTIC LINE (RECORD)FO

UNDERGROUND UTILITY- MULTIPLE SVCS. (EXST.)UU

OVERHEAD FIBER OPTIC LINE (EXST.)OFO

OFO

OVERHEAD TRAFFIC CONTROL LINE (EXST.)OTR

OTR

UNDERGROUND TRAFFIC CONTROL LINE (EXST.)UTR

FARM FIELD TYPE FENCE

GUARDRAIL

SANITARY SEWER (RECORD)SS

WATER LINE (RECORD)W

STORM SEWER (RECORD)ST

GAS LINE (RECORD)G

UNDERGROUND PRIMARY ELECTRIC LINE (EXST.)PE

UNDERGROUND PRIMARY ELECTRIC LINE (RECORD)PE

UNDERGROUND ELECTRIC LINE (RECORD)UE

UNDERGROUND TELECOM/DATA LINE (RECORD)UC

UNDERGROUND UTILITY- MULTIPLE SVCS. (RECORD)

OVERHEAD FIBER OPTIC LINE (RECORD)

OVERHEAD TRAFFIC CONTROL LINE (RECORD)

UNDERGROUND TRAFFIC CONTROL LINE (RECORD)UTR

IRRIGATION LINE (EXST.)IRR

IRRIGATION LINE (RECORD)IRR

OVERHEAD ELECTRIC LINE (RECORD)OE

OVERHEAD UTILITY- MULTIPLE SVCS. (RECORD)OHU

OVERHEAD TELECOM/DATA LINE (RECORD.)OC

TUNNEL (RECORD)

TUNNEL (EXST.) CHILLED WATER LINE (EXST.)CW

CHILLED WATER LINE (RECORD)CW

HOT WATER LINE (EXST.)HW

HOT WATER LINE (RECORD)HW

SS SANITARY SEWER (EXST.)

ST STORM SEWER (EXST.)

STEAM LINE (EXST.)STEAM

STEAM LINE (RECORD)STEAM

NOTE: THE SURVEY DEPICTED ON THIS DRAWING WAS PUBLISHED ON THE DATE CERTIFIED ABOVE AND, THEREFORE, ANY MODIFICATIONS MADE TO THE SITE AFTER THIS DATE ARE NOT CERTIFIED BY BERTSCH-FRANK & ASSOCIATES.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

CONSTRUCTION

DOCUMENT

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

Viridian Architectural Design, Inc.

2020 E. Washington Boulevard Suite 200 Fort Wayne, Indiana 46808

PH: 260.424.4830

www.viridian-design.net

Civil Engineering:

Improve Sewer System and Water Loop

Marion, Indiana

610-21-104

Campus Project Director

06 / 15 / 2023Revisions: Date:

VIRIDIAN

ARCHITECTURAL DESIGN INC.

Engineering Resources, Inc.

4175 New Vision Dr., Fort Wayne, IN 46845

PH: 260-490-1025

Website: ericonsulting

All concepts, ideas, design elements, plans, and details as shown on this document are the sole property of Viridian Architectural Design Inc. and shall not be used for any purpose without prior expressed written consent. The Contracting Officer Representative shall be permitted to retain copies for information and

1. THIS SURVEY WAS PERFORMED FOR THE EXPRESS PURPOSE OF MAPPING THE EXISTING TOPOGRAPHIC FEATURES FOR THE

2. THE UNDERGROUND UTILITY INFORMATION REPRESENTED ON THIS DRAWING WAS DELINEATED USING RECORD INFORMATION, BY FIELD MEASUREMENTS OF VISUAL APPURTENANCES, AND BY A SITE UTILITY-LOCATION SURVEY CONDUCTED BY MASON

PRIVATE LOCATING, (888) 316-3933. ADDITIONAL UNDERGROUND UTILITIES MAY EXIST, THE LOCATIONS OF WHICH WERE NOT DETERMINED AT THE TIME OF THIS SURVEY. ALL UTILITY LOCATIONS ARE APPROXIMATE ONLY.

3. THE LOCATIONS AND DIMENSIONS OF ALL BUILDING STRUCTURES ON THE FACE OF THIS SURVEY ARE APPROXIMATED FOR REFERENCE ONLY. BUILDING DIMENSIONS ARE NOT INTENDED TO BE SCALED FOR STRUCTURAL DETAILING/ DESIGN.

4. THE HORIZONTAL COORDINATES REPRESENTED HEREIN ARE PROJECTED TO NGS NAD 83, INDIANA STATE PLANE EAST. VERTICAL COORDINATES REPRESENTED HEREIN ARE PROJECTED TO NAVD 88. SEE SHEET C0.0 FOR VERTICAL AND HORIZONTAL CONTROL

POINT DESCRIPTIONS.

5. THE DELINEATION OF WETLANDS OR OTHER ENVIRONMENTAL CONDITIONS WERE NOT CONSIDERED AS A PART OF THIS SURVEY.

6. THIS DRAWING IS NOT INTENDED TO BE REPRESENTED AS A RE-TRACEMENT OR ORIGINAL BOUNDARY SURVEY, A ROUTE SURVEY

OR A SURVEYOR LOCATION REPORT.

GENERAL NOTES:

CERTIFICATION:

THE UNDERSIGNED LAND SURVEYOR, REGISTERED UNDER THE LAWS OF THE STATE OF INDIANA, HEREBY CERTIFIES THAT HE HAS MADE A TOPOGRAPHICAL AND UTILITY SURVEY OF THE AREA DEPICTED. I HEREBY CERTIFY THAT TO THE BEST OF MY KNOWLEDGE AND BELIEF THAT THIS PLAT REPRESENTS A TOPOGRAPHIC AND UTILITY SURVEY CONDUCTED UNDER MY DIRECT SUPERVISION.

PROJECT NO.: 21093.100

SURVEYED FOR: VIRIDIAN ARCHITECTURAL DESIGN

DATE(S) OF FIELDWORK: MARCH 23, 2021 - MAY 5, 2021

IN WITNESS THEREOF, I HEREUNTO PLACE MY

HAND AND SEAL THIS 10th DAY OF MAY, 2021.

ROSS M. FRANK

INDIANA REGISTERED LAND SURVEYOR NO. 20500021

CB

LP

E

LP

LP

C

LP

CO

LP

W

W

W

C

C

W

LP

W

W

W

W

CS

W

W W

LP

LP

W

LP

CB

CB

D

CB

CB

D

CB

CB

D

CB

CB

D

D

CB

CB

CB

CB

CB

CB

D

D

CB

CB

D

CB

CB

CB

HC

HC

HC

HC

D

S

CB

CB

CB

LP

LP

W

CO

S

CB

CB

CB

CB

CB

CB

CB

D

D

CB

D

CB

CB

CB

CB

CB

E

CB

CB

CB

CB

CB

CB

CB

D

CB

D

CB

CB

D

D

D

C

S

S

S

D

S

CEBDSCDS

C C

EB

LP

E

LP

E

LP

B B B B

B

LP

LP

DS

DS

DS

DS

DS

C

CB

CB

CB

CB

CB

CB

CB

CB

CB

CB

CB

CB

CB

CB

CB

M 1311088 837.909

MH *ABANDONED UTILITY ACCESS

837.70

VIN

E R

OAD

STEELE CIRCLE DRIVE

S HOME AVENUE / MCMAHON AVENUE

FLOW

ER STREET

STEELE C

IR

C

LE D

R

IV

E

IN

DI

AN

A

AV

EN

UE

BM#7311

BM#7304

BM#7301

HCV#37002

HCV#37001

HCV#31027

HCV#31007 INDIANA AVENUE

BUILDING 93

1-CAR GARAGE

(WOOD SIDING)

BUILDING 34

SINGLE QUARTERS

.7

.6

.9

.1

.6

.4

837.34 837.39

.4

.2

.5

.9

.4

.7

838.05

.6

837.50

838.63838.21 839.51 839.12

839.48 840.82 841.70 841.14 839.69

840.82 841.71 841.15 839.80

840.43 841.30 840.75 839.42

839.92 839.49

841.27 841.05841.76 839.84

839.62

839.26

839.25

839.00

839.07

840.69

840.31

.3

.6

.3

.0

.9

.2

.9

.6

840.87

.2

.6

.3

.8

.4

.9

.2

.8

840.50

.6

.7

842.83

.8

.8

840.79 840.76

.5

.5

.9

.0

.8

.9

.6

.8

840.86 841.34 840.62 839.44

.2

.8

.9

.9

5.

4.

4.

4.

834.37

831.33

830.91

831.75

831.93

834.43

833.13832.71

832.19 831.76

833.38

833.43

837.89

831.78 831.35

831.14

830.73

831.76

831.39

838.30

839.25

838.77 839.56 840.78 841.50 840.65 839.52 839.74

840.74

.2

.5

.3

.9

.1

831.73

9.

1.

1.

831.28 830.90

831.46831.07

832.18831.72

1.

1.

1.

1.

.9

.6

840.12 839.68

9.

9.

.1

.8

.7

.8

9.

.1

.4

.2

.4

840.24

840.11

831.19

831.38 832.26

3.1

5.

0.

831.85

.4

832.59

832.59

.2

.9

832.78

832.54

.3

.3

832.22

832.42 831.97

.0

1.

1.

830.93 830.89

832.50 .8

.3

832.46

832.34

832.32

832.90

.9

832.41

832.28

832.68

.4

832.46

.5

838.52

838.45

837.42

837.32

833.86

7.

7.

6.

.7

.6

5.

.3

.7

.2

.4

.0

.9

.8

832.34 832.46

6.

6.

.7

.8

.2

.1

832.08

1.

2.

2.

839.70839.75

839.69

0.

9.

9.

7.

7.

838.60838.39

836.42

4.

4.

6.

.0

5.

.7

.7

.8

835.30

835.20

836.44

836.40

835.20 835.11

840.15

840.26 836.43

836.62 836.73

841.41

841.50

841.32

841.49

841.32841.22

837.48

.3

.2

.4

841.65

841.38

841.42841.38

841.53 841.54

.2

.4

841.56841.49

.1

.1

840.90

840.89

.6

.5

.3

.1

832.96

833.32

840.53

.0

.3

.6

841.34

841.33

.3

840.50

840.43840.67

840.72

840.64

840.76

839.45

6.

6.

834.05

833.03

.3

.4

834.04

838.33

837.65

835.56

833.86

840.71

839.95

837.39

840.04

835.41

839.18

835.85

837.00

840.61

840.58

840.45

840.13

840.69

833.57

831.60

830.73

831.34

838.89

841.52

843.10

845.11

846.27

847.59

841.98

838.62

840.82

842.02

840.70

840.06

841.44

842.46

841.77

841.61

835.42

APPROXIMATE SECTION LINE

838.68 838.21

838.04

837.98 838.45

837.94 837.78

838.46

838.07 837.89

837.77

839.90

839.87 838.68

840.06

840.23

839.30

838.58

838.65 838.74

838.87 839.87

839.91

838.06

836.11

836.71

836.95

837.80

836.07

836.10836.06

836.05

835.94

835.94835.97

835.97

838.46 838.10 838.12

838.10 837.76 837.79

838.56 837.93

837.93 837.48

837.52

842.80

842.78

.1

.3

837.34

837.22

.9

.9

.2

.9

.9

.2

836.57

.0

.7

.8

.4

.8

.4

.2

.9

.0

.7

.0

.7

.2

.9

.4

.3

.1

.8

836.81

837.22

836.82

837.24

836.50

836.03

836.60

837.34 837.27

.7

836.87

836.61

836.76

836.55 836.91836.51

.4

.0

.8

.1

.4

.7

.4

.3

.3

BUILDING 114

VA POLICE

.7

.7

.4

.0

.6

.8

.4

.0

.3

.9

.3

.9

.2

S HOME AVENUE

SHUTTLE STOP

THRESHOLD

FFE:844.21

10' DIAMETER FOUNTAIN

INDIANA AVE/STEELE CIR AVE SIGN

MCMAHON AVE/STEELE CIR AVE SIGN

ONE WAY SIGN

STOP SIGN

STOP SIGN

YIELD

SIGN

YIELD SIGN

EXIT/MAIN ENTRANCE

DIRECTIONAL SIGN

EXIT/MAIN ENTRANCE

DIRECT…

This is the start of the file's text. The full file is on GovTribe.