Attachment_G-Plans_&_Specifications_for_the_Washington_Street_Building_Remodel_Project.pdf

PDF 45 MB Posted

Attached to
Washington Street Building Remodel Project
Solicitation number
IFB-2023-0120
Issued by
Tuolumne County, Sereno Del Mar CDP, California

About this file

This file contains architectural and engineering plans for the Washington Street Building Remodel Project by Tuolumne County, California. The project involves converting the existing historic Washington Street Courthouse located at 60 North Washington Street in Sonora into new law offices for the county. The comprehensive tenant improvement project includes demolition, architectural modifications, mechanical, electrical, and plumbing upgrades across approximately 5,515 square feet of interior space. The design documents are dated September 8, 2023, and were prepared by Lionakis, a Sacramento-based architectural firm, with engineering support from Capital Engineering Consultants and The Engineering Enterprise.

The project includes two additive alternates: the first involves pressure washing and painting the exterior, while the second involves replacing the entrance canopy on the east side. The renovation will create multiple attorney offices, conference rooms, support spaces, restrooms, and a break room. The plans detail accessibility requirements, ensuring compliance with California Building Code and Americans with Disabilities Act standards. Electrical upgrades include new lighting, power distribution, and lighting control systems, with two existing electrical panels being modified or replaced. The project will maintain the building's existing structural elements and roofing while comprehensively updating the interior to create a modern, functional office environment for the County of Tuolumne's Public Defender's Office.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT LOCATION

VICINITY MAP

OWNER

COUNTY OF TUOLUMNE

2 SOUTH GREEN STREET

SONORA, CA 95370

CONTACT: ERIC ERHARDT

PHONE: 209-533-5511

EMAIL: EERHARDT@CO.TUOLUMNE.CA.US

MECHANICAL ENGINEER

CAPITAL ENGINEERING CONSULTANTS, INC.

11020 SUN CENTER DRIVE

RANCHO CORDOVA, CA 95670

CONTACT: KEVIN STILLMAN

PHONE: 916-851-3500

EMAIL: KSTILLMAN@CAPITAL-ENGINEERING.COM

ARCHITECT

LIONAKIS

2025 19TH STREET

SACRAMENTO, CA 95818

CONTACT: BRANDON RACHAC

PHONE: 916.558.1900

EMAIL: BRANDON.RACHAC@LIONAKIS.COM

STRUCTURAL ENGINEER

LIONAKIS

2025 19TH STREET

SACRAMENTO, CA 95818

CONTACT: ENGINEER CONTACT NAME

PHONE: 916.558.1900

EMAIL: CONTACT EMAIL@LIONAKIS.COM

ELECTRICAL ENGINEER

THE ENGINEERING ENTERPRISE

1125 HIGH STREET

AUBURN, CA 95603

CONTACT: SCOTT WHEELER

PHONE: 530-886-8556

EMAIL: SCOTT@ENGENT.COM

PROJECT DIRECTORY

THE PROJECT CONSISTS OF REMODELING AN EXISTING COUNTY COURTHOUSE INTO NEW LAW

OFFICES.

SCOPE OF PROJECT

REFER TO SHEET GL101 FOR CONSTRUCTION TYPE, OCCUPANCY CLASSIFICATIONS, CODE

ANALYSIS AND LIFE SAFETY FLOOR PLAN.

PROJECT DATA

BUILDING IDENTIFIER - WHERE OCCURS

DISCIPLINE DESIGNATOR - LEVEL 1

DISCIPLINE DESIGNATOR - LEVEL 2

REPLACE DASH WHERE OCCURS

SHEET TYPE SUBSET DESIGNATOR

LEVEL/SEQUENCE DESIGNATOR

AREA IDENTIFIER - WHERE OCCURS

SHEET TYPE DESIGNATOR

C.A-123AB

UNIQUE PORTION IDENTIFIER - WHERE OCCURS

SHEET TYPE DESIGNATORS

0 - GENERAL

1 - PLANS

2 - ELEVATIONS

3 - SECTIONS

4 - LARGE SCALE VIEWS

5 - DETAILS

6 - SCHEDULES & DIAGRAMS

7 - USER DEFINED

8 - USER DEFINED

9 - 3D REPRESENTATIONS

DISCIPLINE DESIGNATORS - LEVEL 1

G GENERAL

H HAZARDOUS MATERIALS

V SURVEY/MAPPING

B GEOTECHNICAL

C CIVIL

L LANDSCAPE

S STRUCTURAL

A ARCHITECTURAL

I INTERIORS

Q EQUIPMENT

F FIRE PROTECTION

P PLUMBING

D PROCESS

M MECHANICAL

E ELECTRICAL

W DISTRIBUTED ENERGY

T TELECOMMUNICATIONS

R RESOURCE

X OTHER DISCIPLINES

Z CONTRACTOR/SHOP DRAWINGS

O OPERATIONS

SHEET IDENTIFICATION LEGEND

ARCHITECTURAL SYMBOLS LEGEND

B3

A-501

B3

A-501

A4

A-201

D2

A-512

TOC 98'-8"

B3

A-301

A2

A-303

A2

A-303

ROOM NAME

NORTH

PLAN

MATCH LINE

SEE XX / X-XXX

A

A-202 A2

A1

A2A4

A3

A-202

LEVEL 1

100'-0"

D2

A-512

D2

A-512

DETAIL INDICATOR - REFERENCE &

DETAIL INDICATOR - ITEM

DETAIL INDICATOR - SECTION & DETAIL

INDICATOR - SECTION ITEM

SECTION INDICATOR - PARTIAL

BUILDING/WALL &

DETAIL INDICATOR - AREA

SECTION INDICATOR - BUILDING

ELEVATION INDICATOR - EXTERIOR

ELEVATION INDICATOR - INTERIOR,

SINGLE & MULTIPLE VIEW

MATCH LINE INDICATOR

REFERENCE GRID WITH REFERENCE GRID LINES

REVISION INDICATOR & REVISION CLOUD

ROOM IDENTIFIER WITH ROOM NAME & NUMBER

ELEVATION INDICATOR - LEVEL & SPOT

WINDOW OR LOUVER IDENTIFIER

KEYNOTE INDICATOR

PLAN NORTH & TRUE NORTH INDICATOR

PROJECT LOCATION

LOCATION MAP

ADD ALTERNATE 1: GENERAL CONTRACTOR TO PRESSURE WASH THE EXTERIOR, PATCH ANY

VOIDS IN EXTERIOR WALLS AND PAINT EXTERIOR PER COLOR CHOSEN BY

THE COUNTY.

ADD ALTERNATE 2: REPLACED ENTRANCE CANOPY ON THE EAST SIDE. COUNTY TO DETERMINE

NAME ON THE CANOPY.

ADDITIVE ALTERNATES

1. FIRE ALARM SYSTEM

DEFERRED SUBMITTALS

1 2 3 4 5

D

C

B

A

SHEET

TITLE

AGENCY

MANAGEMENT

ISSUED

PROJECT

SEAL

CONSULTANT

CLIENT PROJECT NO:

LIONAKIS PROJECT NO:

IF

T

H

IS

S H

E E

T

IS

N O

T

0" x4

2" , I

T

IS

A

R E

D U

C E

D P

R

IN

T

S C

A

LE

A C

C O

R D

IN

G

LY

1/

4"

2"

1"

CLIENT

/1

2/

:3 2:

A

M A ut od es k

D oc s:

//2

.0

W as hi ng to n

S tr ee t T

I/2

.0

1_ A

R C

H M

S T

E R

_A _R

_C

E N

T R

A L.

rv t

G-001

COVER SHEET

60 NORTH WASHINGTON STREET

SONORA, CA 95370

ISSUED FOR PERMIT SET - 100% CD

21077.01

?00.00.00?

COUNTY OF TUOLUMNE

HISTORIC WASHINGTON STREET COURTHOUSE

WASHINGTON STREET COURTHOUSE

SEPTEMBER 8, 2023

TENANT IMPROVEMENT

COUNTY OF TUOLUMNE

TENANT IMPROVEMENT

60 NORTH WASHINGTON STREET

SONORA, CA 95370

2 SOUTH GREENE ST., SONORA, CA

SEE UNITED STATES NATIONAL

CAD STANDARD FOR ANY

ABBREVIATIONS NOT LISTED

BELOW.

& AND

@ AT

(E) EXISTING

' FOOT, FEET

" INCH(ES)

# NUMBER

ALUM ALUMINUM

ARCH ARCHITECTURAL

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT / ENGINEER

AB ANCHOR BOLT

AC ASPHALTIC CONCRETE

ACC ACCESSIBLE

ACS DR ACCESS DOOR

ACS PNL ACCESS PANEL

ACST ACOUSTIC

AD AREA DRAIN

ADC AUTOMATIC DOOR CLOSER

ADO AUTOMATIC DOOR OPERATOR

ADDL ADDITIONAL

ADJ SHV ADJUSTABLE SHELVING

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AGGR AGGREGATE

AHU AIR HANDLING UNIT

ASSY ASSEMBLY

BD BOARD

BKG BACKING

BLDG BUILDING

BM BEAM

BM BENCHMARK

BOT BOTTOM

BTWN BETWEEN

BUR BUILT-UP ROOFING

BW BOTH WAYS

C CHANNEL

CAB CABINET

CB CATCH BASIN

CBC CALIFORNIA BUILDING CODE

CEM CEMENT

CEM PLAS CEM PLASTER

CFLG COUNTERFLASHING

CFMF COLD-FORMED METAL FRAMING

CG CORNER GUARD

CI CAST IRON

CJ CONSTRUCTION JOINT /

CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CNTR COUNTER

CO CLEANOUT

COL COLUMN

CONC CONCRETE

CONSTR CONSTRUCTION

CONT CONTINUE / CONTINUOUS

COTG CLEANOUT TO GRADE

CP CONTROL PANEL

CPT CARPET

CRS COLD ROLLED STEEL

CSK COUNTER SUNK

CSWK CASEWORK

CT CERAMIC TILE

CTR CENTER

DBL DOUBLE

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

LIST OF ARCHITECTURAL ABBREVIATIONS SHEET INDEX

GENERAL

G-001 COVER SHEET

G-002 GENERAL NOTES

GA521 DETAILS - INTERIOR - ACCESSIBILITY

GA522 DETAILS - INTERIOR - ACCESSIBILITY

GA541 DETAILS - DOOR - ACCESSIBILITY

GL111 LIFE SAFETY FLOOR PLAN

ARCHITECTURAL

AD111 DEMOLITION FLOOR PLAN

AD121 DEMOLITION CEILING PLAN

A-111 FLOOR PLAN

A-121 CEILING PLAN

A-131 ROOF PLAN - FOR REFERENCE ONLY

A-141 SIGNAGE FLOOR PLAN & SCHEDULE

A-221 ELEVATIONS - INTERIOR

A-331 SECTIONS - INTERIOR WALL

A-411 LARGE SCALE VIEWS & INT. ELEVATIONS - RESTROOMS

A-521 DETAILS - INTERIOR

A-522 DETAILS - INTERIOR

A-531 PARTITION TYPES & SCHEDULE

A-532 DETAILS - INTERIOR COLD FORMED FRAMING

A-533 DETAILS - INTERIOR COLD FORMED FRAMING

A-541 DETAILS - DOOR FRAME AND WINDOW

A-551 DETAILS - CEILING

A-561 DETAILS - INTERIOR

A-571 DETAILS - SIGNAGE

A-621 SCHEDULES / DIAGRAMS - DOORS

SPEC 05 SPECIFICATIONS - COLD FORMED METAL FRAMING 05 40 00

SPEC 08 SPECIFICATIONS - DOOR HARDWARE 08 71 00

SPEC 08.1 SPECIFICATIONS - DOOR HARDWARE 08 71 00

SPEC 08.2 SPECIFICATIONS - DOOR HARDWARE 08 71 00

SPEC 09 SPECIFICATIONS - GYPSUM BOARD 05 40 00

SPEC 09.1 SPECIFICATIONS - ACOUSTIC PANEL CEILINGS 09 51 13

SPEC 10 SPECIFICATIONS - SIGNAGE 10 14 00

MECHANICAL

M-001 HVAC LEGENDS & NOTES

M-101 HVAC DEMOLITION PLAN

M-201 HVAC PLAN

PLUMBING

P-001 PLUMBING LEGENDS & NOTES

P-002 PLUMBING SCHEDULES

P-101 PLUMBING DEMOLITION PLAN

P-201 PLUMBING PLAN

ELECTRICAL

E-001 SYMBOLS LIST, ABBREVIATIONS, AND SHEET INDEX

E-002 NOTES & SCHEDULES

E-003 TITLE 24

E-130 OVERALL ELECTRCIAL DEMOLITION PLAN

E-230 OVERALL LIGHTING PLAN

E-330 OVERALL POWER PLAN

E-430 OVERALL SPECIAL SYSTEMS PLAN

E-501 POWER ONE LINE DIAGRAM AND DETAILS

2025 Nineteenth Street Sacramento, CA 95818 P 916.558.1900 www.lionakis.com

DHM DETENTION HOLLOW METAL

DIA DIAMETER

DIM DIMENSION

DS DOWNSPOUT

DSP DRY STANDPIPE

DWG DRAWING

DWR DRAWER

EA EACH

EGSB EXTERIOR GYPSUM SHEATHING

BOARD

EIFS EXTERIOR INSULATION AND

FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRIC / ELECTRICAL

ELEV ELEVATOR

EMER EMERGENCY

ENCL ENCLOSURE

EPB ELECTRICAL PANEL BOARD

EQ EQUAL

EQUIP EQUIPMENT

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXH EXHAUST

EXST EXISTING

EXP EXPANSION

EXT EXTERIOR

FA FIRE ALARM

FB FLAT BAR

FD FLOOR DRAIN

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FIN FINISH

FLG FLOORING

FLL FLOW LINE

FLR FLOOR

FOC FACE OF CONCRETE/CURB

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF STUD

FOW FACE OF WALL

FP FIREPROOF

FRP FIBERGLASS REINFORCED

PLASTIC

FT FEET / FOOT

FTG FOOTING

FURG FURRING

FUT FUTURE

G GROUND; NATURAL GAS

GA GAGE

GALV GALVANIZED

GB GRAB BAR

GI GALVANIZED IRON

GLU LAM GLUED LAMINATED WOOD

GYP GYPSUM

HB HOSE BIB

HC HOLLOW CORE

HDBD HARDBOARD

HDW HARDWARE

HDWD HARDWOOD

HM HOLLOW METAL

HORIZ HORIZONTAL

HR HOUR

HT HEIGHT

ID INSIDE DIAMETER

INSUL INSULATION

INT INTERIOR

JAN JANITOR

KIT KITCHEN

L ANGLE

LAB LABORATORY

LAV LAVATORY

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MEMB MEMBRANE

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MR MOISTURE RESISTANT

MTD MOUNTED

MTL METAL

MULL MULLION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

O/ OVER

OC ON CENTER

OD OUTSIDE DIAMETER

OF/CI OWNER FURNISHED /

CONTRACTOR INSTALLED

OFF OFFICE

OGL OBSCURE GLASS

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

PAF POWER ACTUATED FASTENER

PL PROPERTY LINE; PLATE

PLAM PLASTIC LAMINATE

PLB PLUMB

PLBG PLUMBING

PLYWD PLYWOOD

PNL PANEL

PROP PROPERTY

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT; PAINT

PTN PARTITION

PV PHOTOVOLTAIC

QT QUARRY TILE

R RADIUS; RISER

RD ROOF DRAIN

REBAR REINFORCING STEEL BAR

REF REFERENCE

REF REFRIGERATOR

REINF REINFORCE / REINFORCING

REQD REQUIRED

RESIL RESILIENT

RM ROOM

RO ROUGH OPENING

RWD REDWOOD

RWL RAIN WATER LEADER

SAD SEE ARCHITECTURAL

DRAWINGS

SATC SUSPENDED ACOUSTICAL TILE

CEILING

SB SPLASH BLOCK

SC SOLID CORE

SCHED SCHEDULE

SD STORM DRAIN

SDST SELF DRIVING, SELF TAPPING

SHT SHEET

SHTHG SHEATHING

SHV SHELVING

SIM SIMILAR

SLNT SEALANT

SM SHEET METAL

SPEC SPECIFICATION

SQ SQUARE

SS SANITARY SEWER; SERVICE

SINK

SST STAINLESS STEEL

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUSP CLG SUSPENDED CEILING

SV SHEET VINYL

SYMM SYMMETRICAL

SYS SYSTEM

T TREAD

T&G TONGUE & GROOVE

TEL TELEPHONE

THK THICKNESS

TMH TOP OF MANHOLE

TMPD TEMPERED

TO TOP OF

TOC TOP OF CURB

TOF TOP OF FRAME

TOJ TOP OF JOIST

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOPO TOPOGRAPHY

TOS TOP OF STEEL

TOW TOP OF WALL

TV TELEVISION

TYP TYPICAL

UC UNDER COUNTER/CABINET

UNO UNLESS NOTED OTHERWISE

UON UNLESS OTHERWISE NOTED

UR URINAL

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VWC VINYL WALL COVERING

VWF VINYL WALL FABRIC

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WD WOOD

WH WATER HEATER

WO WHERE OCCURS

WP WORKING POINT

WPM WATERPROOF MEMBRANE

WSCT WAINSCOT

WT WEIGHT

WTR WATER

WWR WELDED WIRE

REINFORCEMENT

C27266

L

IC

ENSED A

T

RCHITEC

R 5EN. 0 -30- 2

S

AT

A

T E

OF C A L I FO

R N

I

Y E

VADJ.LEAH

CI

M

MARK DATE DESCRIPTION

1 2 3 4 5

D

C

B

A

SHEET

TITLE

AGENCY

MANAGEMENT

ISSUED

PROJECT

SEAL

CONSULTANT

CLIENT PROJECT NO:

LIONAKIS PROJECT NO:

IF

T

H

IS

S H

E E

T

IS

N O

T

0" x4

2" , I

E

D U

C E

D P

R

IN

T

S C

A

LE

A C

C O

R D

IN

/1

2/

:3 2:

A

M A ut od es k

D oc s:

//2

.0

W as hi ng to n

S tr ee t T

I/2

.0

1_ A

R C

H M

S T

E R

_A _R

_C

E N

T R

A L.

rv t

G-002

GENERAL NOTES

21077.01

?00.00.00?

COUNTY OF TUOLUMNE

TENANT IMPROVEMENT

60 NORTH WASHINGTON STREET

SONORA, CA 95370

2 SOUTH GREENE ST., SONORA, CA

2025 Nineteenth Street Sacramento, CA 95818 P 916.558.1900 www.lionakis.com

GENERAL NOTES

1. ALL CONSTRUCTION SHALL CONFORM TO THE MINIMUM STANDARDS OF THE 2022 EDITION OF

THE CALIFORNIA BUILDING CODE (C.B.C.) AND THE REQUIREMENTS OF TITLE 24 CALIFORNIA

CODE OF REGULATIONS.

2. THE CONTRACTOR SHALL OBTAIN AND MAINTAIN AT THEIR EXPENSE ALL NECESSARY PERMITS

AND LICENSES FOR THE COMPLETION OF THIS JOB.

3. THE CONTRACTOR SHALL VISIT THE PREMISE WHERE THIS WORK IS TO BE PERFORMED AND

VERIFY ALL SITE CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION.

4. DIMENSIONS ARE GIVEN TO FACE OF EXISTING SURFACES, CMU, OR CONCRETE AND TO THE

FACE OF STUDS UNLESS NOTED OTHERWISE.

5. HEIGHT DIMENSIONS ARE GIVEN TO THE FINISH FLOOR LINE EXCLUSIVE OF FLOOR COVERING.

6. VERIFY DIMENSIONS AND LOCATIONS OF ALL OPENINGS, BASES, ETC., AND SPECIAL

PROVISIONS REQUIRED FOR EQUIPMENT, DUCTS, PIPING, CONDUITS, FINISH HARDWARE, ETC.

7. AT OPENINGS PLACE FLOORING TRANSITION STRIPS UNDER CENTERLINE OF DOOR. WHERE

ADJOINING ROOMS HAVE COMPOSITION OF DIFFERENT COLORS, PLACE STRIP AS NOTED ON

FINISH FLOOR PLAN.

8. THE CONTRACTOR SHALL PROVIDE DUST-PROOF BARRIERS AT OPENINGS INTO ADJACENT

ROOMS AND FINISH AREAS AND WILL LEAVE WORK AREA IN A NEAT AND ORDERLY FASHION AT

THE END OF EACH WORKING DAY. DUST PROTECTION HALL BE CONSTRUCTED FROM

MATERIALS APPROVED BY THE CALIFORNIA STATE FIRE MARSHAL.

9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES TO THE EQUIPMENT,

FURNITURE OR PREMISES INCURRED AS A RESULT OF WORK INCURRED HEREIN. ANY SUCH

DAMAGES SHALL BE REPAIRED TO THE OWNERS SATISFACTION AT NO INCREASE IN THE

CONTRACT AMOUNT.

10. ALL GLASS DOORS, SIDELIGHTS, AND GLAZED OPENINGS WITHIN 18 INCHES OF THE FLOOR OR

WITHIN 24 INCHES HORIZONTAL OF ANY DOOR OPENING SHALL BE FULLY TEMPERED GLASS

APPROVED FOR IMPACT HAZARD.

11. UNLESS DIMENSIONED OTHERWISE, DOOR RETURNS AT THE HINGE SIDE SHALL BE A MINIMUM

OF 4" FROM THE ADJACENT WALL.

12. THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL ACCESS PANELS REQUIRED

IN WALLS AND CEILINGS, POWER, LIGHTING, SWITCHING, COORDINATION OF FIRE ALARM AND

LIFE SAFETY SYSTEMS, ETC.

13. THE CONTRACTOR SHALL PATCH, REPAIR AND INCORPORATE MATERIALS AND LABOR

NECESSARY TO COMPLETE AND FINISH ALL NEW AND REMODELED AREAS TO MATCH FIT,

FINISH AND QUALITY CONSISTENT WITH THE EXISTING BUILDING. MATERIALS AND PRODUCTS

SHALL BE FINISHED AND INSTALLED, I.E.; SEAMED, JOINTED AND PAINTED IN A UNIFORM

MANNER CONSISTENT IN MATCHING EXISTING ADJACENT PATTERNS, TEXTURES AND COLORS.

14. EXIT DOORS SERVING 50 OR MORE OCCUPANTS SHALL OPEN IN THE DIRECTION OF EXIT.

(CHAPTER 10 CBC)

15. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, SPECIAL

KNOWLEDGE OR EFFORT. (CHAPTER 11B CBC 2019). NOTE ALSO THAT FLUSH BOLTS OR

SURFACE BOLTS ARE PROHIBITED.

16. THE EXIT DOOR MUST OPEN OVER A LANDING NOT MORE THAN 1/2" BELOW THE THRESHOLD.

(CHAPTER 10 CBC)

17. DOORS WHEN FULLY OPENED AND HANDRAILS SHALL NOT REDUCE THE REQUIRED WIDTH OF

REQUIRED CORRIDORS BY MORE THAN 7 INCHES. DOORS IN ANY POSITION SHALL NOT

REDUCE THE REQUIRED WIDTH BY MORE THAN ONE HALF (CHAPTER 10 2019 CBC)

18. NO CHANGES SHALL BE MADE TO THE WORK NOTED ON THESE DRAWINGS WITHOUT THE

WRITTEN KNOWLEDGE AND CONSENT OF THE OWNER AND ARCHITECT. THE CONTRACTOR

SHALL NOTIFY THIS OFFICE OF ANY CONDITIONS FOUND THAT, IN THEIR OPINION, WOULD BE

DESIRABLE TO MODIFY OR CHANGE TO PRODUCE THE BEST RESULTS.

19. DIMENSIONS AS INDICATED ARE THE DIMENSIONS TO BE USED FOR CONSTRUCTION; DO NOT

SCALE THE DRAWINGS. IF A DIMENSION IS IN DOUBT, REQUEST CLARIFICATION FROM THE

ARCHITECT BEFORE PROCEEDING WITH THAT WORK. DIMENSIONS ARE TO FACE OF STUD

UNLESS NOTED OTHERWISE.

20. EXIT ILLUMINATION AND EXIT SIGN REQUIREMENTS SHALL COMPLY WITH 2019 CBC

21. THE MAXIMUM FORCE REQUIRED TO PUSH OR PULL A DOOR OPEN SHALL COMPLY WITH 2019

CBC 11B-404.2.0. OTHER THAN REQUIRED FIRE DOORS, INTERIOR DOORS SHALL HAVE A

MAXIMUM FORCE OF 5 LB/F. FIRE RATED DOORS SHALL NOT EXCEED 15 LB/F.

22. THE PROJECT IS SUBJECT TO THE NOISE STANDARDS ESTABLISHED IN THE CITY'S NOISE

ORDINANCE. PROJECT CONSTRUCTION IS EXEMPT ONLY DURING THE HOURS ALLOWED IN THE

CITY'S NOISE ORDINANCE. HOWEVER, ALL CONSTRUCTION EQUIPMENT SHALL BE MAINTAINED

AND IN GOOD WORKING ORDER, FITTED WITH FACTORY INSTALLED MUFFLING DEVICES.

B. ENTRANCES

1. ALL ACCESSIBLE ENTRANCES SHALL BE IDENTIFIED WITH AT LEAST ONE STANDARD SIGN AND

WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE FROM APPROACHING

PEDESTRIAN WAYS.

2. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE OF A SIZE AS TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 3 FEET IN WIDTH AND NOT LESS THAN 6 FEET, 8- INCHES IN HEIGHT. DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL

BE SO MOUNTED THAT THE CLEAR WIDTH OF THE DOORWAY IS NOT LESS THAN 32-INCHES.

3. WHERE A PAIR OF DOORS IS UTILIZED AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR

UNOBSTRUCTED OPENING WIDTH OF 32-INCHES WITH THE LEAF POSITIONED AT AN ANGLE OF

90 DEGREES FROM ITS CLOSED POSITION.

4. WHEN AN AUTOMATIC DOOR OPERATOR IS UTILIZED TO OPERATE A PAIR OF DOORS, AT LEAST

ONE OF THE DOORS SHALL PROVIDE A CLEAR UNOBSTRUCTED OPENING WIDTH OF 32-INCHES

WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.

5. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF

TRAVEL, SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE

WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE.

6. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30- INCHES AND

44-INCHES ABOVE THE FLOOR.

7. THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE LEVEL

AND CLEAR. THE LEVEL AND CLEAR AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR

SWING OF AT LEAST 60-INCHES AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING

OF 48-INCHES AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED

POSITION.

8. THE WIDTH OF THE LEVEL AND CLEAR AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL

EXTEND 24-INCHES PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18-

INCHES PAST THE STRIKE EDGE FOR INTERIOR DOORS.

9. THE BOTTOM 10-INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A

SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR

FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME

DOORS ARE USED, A 10-INCH HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE

OF THE DOOR, WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST

WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION.

10. A NARROW FRAME WITH A BEVELED TOP EDGE (30 DEGREES MAXIMUM BEVEL TO VERTICAL

PLANE) INSTALLED AT THE BOTTOM OF A GLASS DOOR (WITH NO SIDE FRAMES) MAY BE USED IN

LIEU OF PROVIDING THE REQUIRED 10-INCH UNINTERRUPTED SURFACE AT THE BOTTOM OF

THE DOOR.

11. THE SPACE BETWEEN THE CONSECUTIVE DOOR OPENINGS IN A VESTIBULE, SERVING OTHER THAN A REQUIRED EXIT STAIRWAY SHALL PROVIDE A MINIMUM OF 48-INCHES OF CLEAR SPACE

FROM ANY DOOR OPENING INTO EACH VESTIBULE WHEN THE DOOR IS POSITIONED AT AN

ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. DOORS IN A SERIES SHALL SWING EITHER

IN THE SAME DIRECTION OR AWAY FROM THE SPACE BETWEEN THE DOORS.

C. SANITARY FACILITIES

1. WHEN SANITARY FACILITIES ARE LOCATED ON ACCESSIBLE FLOORS OF A BUILDING, THEY

SHALL BE MADE ACCESSIBLE TO THE PHYSICALLY DISABLED.

2. WHERE SEPARATE FACILITIES ARE PROVIDED FOR NON-DISABLED PERSONS OF EACH SEX,

SEPARATE FACILITIES SHALL BE PROVIDED FOR DISABLED PERSONS OF EACH SEX ALSO.

WHERE UNISEX FACILITIES ARE PROVIDED FOR NON-DISABLED PERSON, SUCH UNISEX

FACILITIES MAY BE PROVIDED FOR THE DISABLED.

3. ALL DOORWAYS LEADING TO SANITARY FACILITIES SHALL HAVE 32-INCH CLEAR

UNOBSTRUCTED OPENINGS.

4. ON DOORWAYS LEADING TO MEN'S SANITARY FACILITIES, AN EQUILATERAL TRIANGLE 1/4 -

INCH THICK WITH EDGES 12-INCHES LONG AND A VERTEX POINTING UPWARD SHALL BE

PROVIDED AND ON DOORWAYS LEADING TO WOMEN'S SANITARY FACILITIES A CIRCLE 1/4 -

INCH THICK AND 12-INCHES IN DIAMETER SHALL BE PROVIDED. THESE GEOMETRIC SYMBOLS

SHALL BE CENTERED ON THE DOOR AT A HEIGHT OF 60-INCHES AND THEIR COLOR AND

CONTRAST SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR AND CONTRAST OF THE

DOOR.

5. A CLEAR SPACE MEASURED FROM THE FLOOR TO A HEIGHT OF 27-INCHES ABOVE THE

FLOOR, WITHIN THE SANITARY FACILITY ROOM, OF SUFFICIENT SIZE TO INSCRIBE A CIRCLE

WITH A DIAMETER NOT LESS THAN 60-INCHES, OR A CLEAR SPACE NOT LESS THAN 56-

INCHES X 63- INCHES IN SIZE SHALL BE PROVIDED. DOORS OTHER THAN THE DOOR TO THE

DISABLED TOILET COMPARTMENT IN ANY POSITION MAY ENCROACH INTO THIS SPACE BY

NOT MORE THAN 12-INCHES.

6. THE CENTERLINE OF THE ACCESSIBLE WATER CLOSET SHALL BE 16" MIN AND 18" MAX FROM

THE SIDE WALL OR PARTITION. A MIN 60" WIDE AND 48" DEEP MANEUVERING SPACE SHALL

BE PROVIDED IN FRONT OF THE WATER CLOSET.

7. WATER CLOSET COMPARTMENTS SHALL BE EQUIPPED WITH A DOOR THAT HAS AN

AUTOMATIC CLOSING DEVICE AND SHALL HAVE A CLEAR UNOBSTRUCTED OPENING WIDTH

OF 32-INCHES WHEN LOCATED AT THE END AND 34-INCHES WHEN LOCATED AT THE SIDE

WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.

8. EXCEPT FOR DOOR OPENING WIDTHS AND DOOR SWINGS, A CLEAR UNOBSTRUCTED

ACCESS NOT LESS THAN 44-INCHES SHALL BE PROVIDED TO WATER CLOSET

COMPARTMENTS DESIGNED FOR USE BY THE DISABLED. THE SPACE IMMEDIATELY IN

FRONT OF A WATER CLOSET COMPARTMENT SHALL BE NOT LESS THAN 48-INCHES AS

MEASURED AT RIGHT ANGLES TO THE COMPARTMENT DOOR IN ITS CLOSED POSITION.

D. TOILET ROOM FIXTURES AND ACCESSORIES

1. THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE A MINIMUM OF 17-INCHES AND A

MAXIMUM OF 19-INCHES MEASURED TO THE TOP OF THE TOILET SEAT.

2. TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE

TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR THE FLUSH

VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS, NO MORE THAN

44-INCHES ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO

GREATER THAN 5 POUNDS.

3. WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE A CLEAR SPACE 30-INCHES WIDE

X 48 -INCHES LONG IN FRONT OF THE URINAL.

4. WHERE URINALS ARE PROVIDED, AT LEAST ONE WITH A RIM PROJECTING A MINIMUM OF 14-

INCHES FROM THE WALL AND AT A MAXIMUM OF 17-INCHES ABOVE THE FLOOR SHALL BE

PROVIDED.

5. A CLEAR FLOOR SPACE 30-INCHES WIDE X 48-INCHES LONG SHALL BE PROVIDED IN FRONT OF

A LAVATORY TO ALLOW A FORWARD APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN

OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND INTO KNEE AND TOE SPACE

UNDERNEATH THE LAVATORY.

6. LAVATORIES SHALL BE MOUNTED WITH A CLEARANCE OF AT LEAST 29-INCHES FROM THE

FLOOR TO THE BOTTOM OF THE APRON WITH KNEE CLEARANCE UNDER THE FRONT LIP

EXTENDING A MINIMUM OF 30-INCHES IN WIDTH WITH 3-INCHES MINIMUM DEPTH AT THE TOP.

TOE CLEARANCE SHALL BE THE SAME WIDTH AND SHALL BE A MINIMUM OF 9-INCHES HIGH

FROM THE FLOOR AND A MINIMUM OF 17-INCHES DEEP FROM THE FRONT OF THE LAVATORY.

7. A PROJECTION OF A LAVATORY BOWL INTO THE 8-INCH CLEAR SPACE, THEREBY REDUCING

THE CLEAR HEIGHT BELOW THE LAVATORY TO NO LESS THAN 27-INCHES AT 8-INCHES BACK

FROM THE APRON, MEETS THE REQUIREMENT FOR PROVIDING KNEE CLEARANCE.

8. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE

COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.

9. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND

AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE

FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS PER

FOOT. LEVER-OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE

EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET

REMAINS OPEN FOR AT LEAST 10 SECONDS.

10. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE NOT

MORE THAN 40-INCHES FROM THE FLOOR.

11. LOCATE TOWEL, SANITARY NAPKIN, AND WASTE RECEPTACLES WITH ALL OPERABLE PARTS

NOT MORE THAN 40-INCHES FROM THE FLOOR.

12. LOCATE TOILET TISSUE DISPENSERS ON THE WALL OR PARTITION CLOSEST TO THE WATER

CLOSET 7" MIN AND 9" MAX IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLINE

OF THE DISPENSER, MOUNTED BELOW THE GRAB BAR WITH THE OUTLET OF THE DISPENSER

AT A MIN HEIGHT OF 19".

13. GRAB BARS, FASTENERS AND MOUNTING DEVICES SHALL BE DESIGNED FOR 250 LB. PER

LINEAR FOOT LOAD.

E. GRAB BARS

1. GRAB BARS SHALL BE LOCATED ON ONE SIDE AND THE BACK OF THE ACCESSIBLE

COMPARTMENT AND SHALL BE SECURELY ATTACHED 33-INCHES TO BAR CENTERLINE AND

PARALLEL TO THE FLOOR.

2. GRAB BARS AT THE SIDE SHALL BE AT LEAST 48-INCHES LONG WITH THE FRONT END

POSITIONED 24-INCHES IN FRONT OF THE WATER CLOSET STOOL, AND GRAB BARS AT THE

BACK SHALL BE NOT LESS THAN 42-INCHES LONG.

3. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1-1/4

INCHES TO 1-1/2 INCHES IN DIAMETER OR AS NOTED ON PLANS.

4. IF THE GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL

AND THE GRAB BARS SHALL BE 1-1/2 INCHES.

5. A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY

SHARP OR ABRASIVE ELEMENTS.

6. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.

F. ADDITIONAL A.D.A. REQUIREMENTS

1. THE CENTER OF THE RECEPTACLE OUTLETS SHALL BE NO MORE THAN 48" MEASURED FROM

THE TOP OF THE RECEPTACLE OUTLET BOX NOR LESS THAN 15" MEASURED FROM THE

BOTTOM OF THE RECEPTACLE BOX TO THE LEVEL OF THE FLOOR OR PLATFORM

2. THE CENTER OF THE GRIP OF THE OPERATING HANDLE OF SWITCHES INTENDED TO BE USED

BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE

OUTLETS, APPLIANCES, OR COOLING, HEATING AND VENTILATING EQUIPMENT, SHALL BE NOT

LESS THAN 15" NOR MORE THEN 48" ABOVE THE FLOOR OR WORKING PLATFORM.

3. THE CENTER OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE LOCATED 48- INCHES

ABOVE THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK.

4. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY

FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY DISABLED PERSONS AS

SET FORTH IN THESE BUILDING STANDARDS. THE SYMBOL SPECIFIED ABOVE SHALL CONSIST

OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO.

15090 IN FEDERAL STANDARD 595A.

5. EMERGENCY WARNING SYSTEMS ARE REQUIRED TO INCLUDE AN INTEGRATED MEANS OF

WARNING THE HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY

OF NOT MORE THAN 60 FLASHES PER MINUTE.

6. NOTE: AT LEAST 5%, AND A MINIMUM OF 36" OF EACH TABLE/ COUNTER WORK SURFACE

AND/OR TRANSACTION STATION IN EMPLOYEE WORK AREAS, OR WHERE TRANSACTIONS

OCCUR BETWEEN SALES AND EMPLOYEES AND CUSTOMERS SHALL HAVE A SURFACE WHICH

IS BETWEEN 28" AND 34" ABOVE FLOOR. (CHAPTER 11 CBC)

7. ALL COMMON-USE KITCHEN AND/OR BAR/SINK AREAS SHALL HAVE CONTROLS THAT SHALL

BE (1) OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE GRASPING, PINCHING, OR

TWISTING OF THE WRIST; (2) REQUIRE NO MORE THAN 5 LBS. FORCE TO ACTIVATE; AND (3) BE

LEVER-OPERATED,PUSH TYPE, ELECTRONICALLY CONTROLLED OR SIMILAR.

G. GENERAL FIRE DEPARTMENT NOTES

1. CONSTRUCTION MATERIAL AND VEHICLES SHALL NOT OBSTRUCT FIRE APPARATUS ROADS,

FIRE HYDRANTS OR THE BUILDING.

2. BARRICADES SHALL BE PROVIDED TO PROTECT ANY NATURAL GAS METER, FIRE HYDRANT,

FIRE DEPARTMENT CONTROL DEVICE, OR OTHER POSSIBLE PERTINENT EQUIPMENT OR

DEVICES THAT MAY BE SUBJECT TO VEHICULAR DAMAGE.

3. PROVIDE AND MAINTAIN A MINIMUM 3-FOOT CLEAR SPACE AROUND FIRE PROTECTION

EQUIPMENT.

4. THE ALARM/FIRE WARNING SYSTEM SHALL BE CERTIFIED BY UNDERWRITER'S LABORATORY

(UL), AND SHALL BE MAINTAINED IN ACCORDANCE WITH CITY STANDARDS. PROOF OF

CERTIFICATION SHALL BE PROVIDED PRIOR TO APPROVAL OF OCCUPANCY. ADDITIONAL

WARNING DEVICES SHALL BE PROVIDED WHERE REQUIRED TO ASSIST THE HEARING IMPAIRED.

ALL DIGITAL ALARM COMMUNICATION TRANSMITTERS SHALL REPORT DISTINCTIVE SIGNALS

FROM THE SITE FOR WATER FLOW (BY BUILDING), GENERAL FIRE ALARM, SUPERVISORY AND

SYSTEM TROUBLE CONDITIONS.

5. THE BURNING OF COMBUSTIBLE CONSTRUCTION MATERIALS AND TRASH IS PROHIBITED.

6. TEMPORARY HEATING DEVICES SHALL BE OF AN APPROVED TYPE, LOCATED AWAY FROM

COMBUSTIBLE MATERIALS AND ATTENDED AND MAINTAINED AT ALL TIMES. HEATING DEVICES

SHALL NOT BE OPERATED AFTER NORMAL WORKING HOURS WITHOUT BEING ATTENDED TO ON

AN HOURLY BASIS.

7. CUTTING AND WELDING OPERATIONS SHALL CONFORM TO THE HOT WORK PROVISIONS OF

ARTICLE 49 OF THE CALIFORNIA FIRE CODE OR THE CITY FIRE CODE. A FIRE WATCH SHALL BE

PROVIDED DURING HOT WORK ACTIVITIES AND SHALL CONTINUE FOR A MINIMUM OF 30

MINUTES AFTER THE CONCLUSION OF THE WORK.

8. FIRE SAFETY DURING CONSTRUCTION SHALL COMPLY WITH ARTICLE 87 OF THE CALIFORNIA

FIRE CODE AS AMENDED BY THE CITY OF SACRAMENTO.

9. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN OCCUPANCIES AND LOCATIONS AS SET FORTH IN THE CALIFORNIA FIRE CODE AND TITLE 19 CCR DIVISION 1, CHAPTER 3 AND AS

REQUIRED BY THE CHIEF. PROVIDE A MINIMUM OF ONE (1) PORTABLE FIRE EXTINGUISHER

WITHIN EACH TENANT SPACE. THE MAXIMUM TRAVEL DISTANCE TO THE FIRE EXTINGUISHER

SHALL NOT EXCEED 75 FEET. THE MINIMUM RATING CLASSIFICATION FOR THE EXTINGUISHER

SHALL BE NOT LESS THAN 2A-10B:C. THE MAXIMUM TRAVEL DISTANCE FROM ANY POINT IN A

LIGHT HAZARD AREA OF CLASS A HAZARDS SHALL NOT BE MORE THAN 75 FEET FROM A CLASS

2A-10B:C ONE EXTINGUISHER SHALL BE PROVIDED FOR EACH 3000 SQUARE FEET. THE

MAXIMUM TRAVEL DISTANCE FROM ANY POINT IN AN ORDINARY HAZARD OF CLASS A HAZARDS

AREA SHALL NOT BE MORE THAN 75 FEET AND ONE EXTINGUISHER SHALL BE PROVIDED FOR

EACH 3000 SQUARE FEET. THE MAXIMUM TRAVEL DISTANCE TO CLASS B EXTINGUISHERS IS

EITHER 30 FEET OR 50 FEET DEPENDING UPON THE SIZE OF THE EXTINGUISHER AND THE

CLASSIFICATION OF THE HAZARD. REFER TO UFC STANDARD NO. 10-1 FOR COMPLETE

REQUIREMENTS. ALL PORTABLE FIRE EXTINGUISHERS SHALL HAVE A SERVICE TAG AFFIXED TO

THEM SHOWING THAT THE EXTINGUISHER HAS BEEN SERVICED BY A CALIFORNIA STATE

LICENSED FIRE EXTINGUISHER CONCERN. ALL FIRE EXTINGUISHERS SHALL BE ATTACHED TO A

BRACKET OR WITHIN AN APPROVED CABINET. MAXIMUM DISTANCE FROM THE FLOOR SHALL

NOT EXCEED 54 INCHES. SIGNAGE SHALL BE POSTED ABOVE THE EXTINGUISHER AND SHALL

READ "FIRE EXTINGUISHER."

10. A SEPARATE PLAN CHECK SUBMITTAL AND PERMIT IS REQUIRED FOR ANY CHANGES NEEDED

TO THE EXISTING FIRE ALARM SYSTEM DUE TO THE TENANT IMPROVEMENT CONSTRUCTION OR

EXISTING CONDITIONS THAT ARE OUT OF CURRENT CODE COMPLIANCE. PLANS, INCLUDING

SEQUENCE OF OPERATIONS MATRIX, ZONES OR ADDRESS DESCRIPTIONS, POINT-TO-POINT

RISER DIAGRAM, BATTERY & VOLTAGE DROP CALCULATIONS AND C.S.F.M. LISTING APPROVAL

INFORMATION SHEETS, ETC., MUST BE SUBMITTED TO THE PERMIT COUNTER AT CITY HALL FOR

PLAN CHECK APPROVAL AND FIRE PERMIT FROM THE FIRE DEPARTMENT PRIOR TO

INSTALLATION.

FIRE SAFETY NOTES

1. ALL CONCEALED SPACES IN COMBUSTIBLE CONSTRUCTION ARE TO BE PROTECTED BY

AUTOMATIC FIRE SPRINKLERS UNLESS SPECIFICALLY EXEMPTED BY THE 2013 EDITION OF

NFPA 13 SECTION 8.15.1. OMITTING THE SPRINKLERS FROM SOME CONCEALED SPACES AS

PERMITTED BY SECTION 5-13. MAY REQUIRE THAT THE DESIGN AREA BE INCREASED IN

ACCORDANCE WITH SECTION 7-2.3.1.3

2. FIRE BLOCKING IS TO BE INSTALLED AS REQUIRED BY CBC SECTION 717. EXCEPTION: FIRE

BLOCKING WILL NOT BE REQUIRED AT 10-FOOT INTERVALS VERTICALLY IN EXTERIOR

COLUMNS AND FURRED SPACES ON THE EXTERIOR SIDE OF WALLS PROVIDED ALL OF THE

FOLLOWING CONDITIONS ARE SATISFIED:

1. THE CONCEALED SPACE IS ON THE EXTERIOR OF THE BUILDING;

2. THE CONCEALED SPACE IS VERTICAL;

3. THE CONCEALED SPACE DOES NOT EXCEED 10 FEET HORIZONTALLY BETWEEN

FIRE BLOCKING;

4. THERE ARE NO POTENTIAL SOURCES OF IGNITION WITHIN THE CONCEALED

SPACE;

5. THE INTERIOR CAVITY OF A COLUMN OR FURRED SPACE IS PROTECTED BY A FIRE

SPRINKLER(S) INSTALLED IN ACCORDANCE WITH UBC STANDARD 9-1. (THE FIRE

SPRINKLER(S) IS AT THE TOP OF THE CONCEALED SPACE, NOT IN AN ATTIC

CONNECTED TO THE CONCEALED SPACE); AND

6. THE CONCEALED SPACE IS FIRE-BLOCKED TO SEPARATE IT FROM ALL

HORIZONTAL CONCEALED SPACES SUCH AS SOFFITS, FLOOR-CEILING

ASSEMBLIES AND ATTICS.

H. REQUIREMENTS BY THE FIRE DEPARTMENT

1. INTERIOR WALL AND CEILING FINISHES FOR ASSEMBLY AREAS SHALL NOT EXCEED A FLAME-

SPREAD CLASSIFICATION OF 200 (CLASS III).

2. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A:10BC

WITHIN (75) FOOT TRAVEL DISTANCE TO: ALL PORTIONS OF THE BUILDING ON EACH FLOOR

DURING CONSTRUCTION.

3. WHERE REQUIRED, ROOM OCCUPANCY CAPACITIES SHALL BE POSTED WITH SIGNS

COMPLYING WITH THE REQUIREMENTS OF 2019 CBC SECTION AND TITLE 19 DIV. 1, CH.1

ARTICLE 3, SECTION 3.30

4. EXIT LIGHTING AND SIGNS: (CHAPTER 10 CBC) MINIMUM 6" x 3/4" LETTERS ON CONTRASTING

BACKGROUND.

5. EMERGENCY LIGHTING SHALL BE PROVIDED GIVING A VALUE OF ONE FOOT CANDLE AT

FLOOR LEVEL: (CHAPTER 10 CBC).

6. ONLY FIRE EXIT HARDWARE APPROVED BY THE STATE FIRE MARSHAL SHALL BE INSTALLED.

7. PROVIDE PORTABLE FIRE EXTINGUISHER WITH A RATING NOT LESS THAN 4A60 BC FOR

ELECTRICAL ROOM, AND MECHANICAL ROOM.

8. ROOF OBSTRUCTION SUCH AS TELEVISION ANTENNA, GUY WIRES, SOLAR PANELS, AND

RIBBON SHALL NOT PREVENT FIRE DEPARTMENT ACCESS OR EGRESS. FIRE DEPARTMENT

ACCESS TO ROOFS IN THE EVENT OF A FIRE SHALL NOT BE OBSTRUCTED BY WIRES,

RAZOR RIBBON, FENCES, CABLES, AERIALS, ANTENNAS, OR SOLAR PANELS.

9. EXIT SIGNS SHALL BE ELECTRICALLY ILLUMINATED AND THE TWO LAMPS SHALL BE

ENERGIZED FROM SEPARATE CIRCUITS. ILLUMINATION SHALL NORMALLY BE PROVIDED

BY THE PREMISES WIRING SYSTEM. IN THE EVENT OF FAILURE OF THIS SYSTEM,

ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY SYSTEM.

EMERGENCY LIGHTING SHALL GIVE A VALUE OF ONE FOOT CANDLE AT FLOOR LEVEL. (TITLE

24, C.C.R.).

10. EXIT PATH LIGHTING SHALL BE PROVIDED FOR STAIRWAY, HALLWAY, EXIT PASSAGEWAY AND

EGRESS TO A PUBLIC WAY ANY TIME THE BUILDING IS OCCUPIED.

11. PROVIDE TACTILE EXIT SIGNS WHERE REQUIRED (CHAPTER 10 CBC)

12. FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS TO MEET

REQUIREMENTS OF 2019 CBC SECTION 703.7.

G. DRINKING FOUNTAINS

1. WHERE WATER FOUNTAINS ARE PROVIDED OUTSIDE THE AREA OF REMODEL, THEY SHALL

COMPLY WITH DISABLED ACCESS REQUIREMENTS.

2. WATER FOUNTAINS SHALL BE LOCATED COMPLETELY WITHIN ALCOVES OR OTHERWISE

POSITIONED SO AS NOT TO ENCROACH INTO PEDESTRIAN WAYS. THE ALCOVE IN WHICH THE

WATER FOUNTAIN IS LOCATED SHALL BE NOT LESS THAN 32-INCHES IN WIDTH AND 18-

INCHES IN DEPTH.

3. THE DRINKING FOUNTAIN SHALL BE A MINIMUM OF 18-INCHES IN DEPTH AND THERE SHALL BE

CLEAR AND UNOBSTRUCTED KNEE SPACE UNDER THE DRINKING FOUNTAIN NOT LESS THAN

27-INCHES IN HEIGHT AND 8-INCHES IN DEPTH, THE DEPTH MEASUREMENT BEING TAKEN

FROM THE FRONT EDGE OF THE FOUNTAIN. ADDITIONALLY THERE SHALL BE TOE

CLEARANCE OF 9-INCHES IN HEIGHT ABOVE THE FLOOR, AND 17-INCHES IN DEPTH FROM THE

FRONT EDGE OF THE FOUNTAIN. A SIDE APPROACH DRINKING FOUNTAIN IS NOT

ACCEPTABLE.

4. THE BUBBLER SHALL BE ACTIVATED BY A CONTROL WHICH IS EASILY OPERATED BY A

DISABLED PERSON SUCH AS A HAND-OPERATED LEVER TYPE CONTROL LOCATED WITHIN 6-

INCHES OF THE FRONT OF THE DRINKING FOUNTAIN ETC. THE BUBBLER OUTLET ORIFICE

SHALL BE LOCATED WITHIN 6-INCHES OF THE FRONT OF THE DRINKING FOUNTAIN AND SHALL

BE WITHIN 36-INCHES OF THE FLOOR. THE WATER STREAM FROM THE BUBBLER SHALL BE

SUBSTANTIALLY PARALLEL TO THE FRONT EDGE OF THE DRINKING FOUNTAIN.

C27266

L

IC

ENSED A

T

RCHITEC

R 5EN. 0 -30- 2

S

AT

A

T E

OF C A L I FO

R N

I

Y E

VADJ.LEAH

CI

INTERIOR - ACCESSORIES - MOUNTING HEIGHTS & LOCATIONS

0500_0100_ACC MOUNTING HEIGHT ACCESSORIES_01

171108

M A

X

ACC LAV

(ACC SINK SIM.)

NOTE:

1. AT ACCESSIBLE TOILET STALLS, OPENING FOR PARTITION DOOR SHALL BE MIN. 34" CLEAR, DOOR SHALL BE SELF CLOSING, AND AN ACCESSIBLE DOOR

PULL SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH.

2. PROVIDE BACKING FOR ALL WALL HUNG ACCESSORIES, SEE TYPICAL BACKING DETAIL

3. BACKING LOCATIONS SHALL BE COORDINATED W/ ANCHORAGE LOCATIONS, TYP.

4. SEE INTERIOR ELEVATIONS FOR DEFINITIONS OF ACCESSORY ABBREVIATIONS.

5. WHERE WALL MOUNTED EQUIPMENT IS LOCATED ABOVE COUNTER/WORK SURFACE, HEIGHT TO OPERABLE PART SHALL BE 46" MAX. FOR PARALLEL

APPROACH.

6. WHERE WALL MOUNTED EQUIPMENT IS LOCATED ABOVE COUNTER/WORK SURFACE, HEIGHT TO OPERABLE PART FOR FORWARD APPROACH IS 48" MAX.

WHEN COUNTER/WORK SURFACE IS A MAXIMUM OF 20" DEEP. WHEN REACH DEPTH IS BETWEEN 20" AND THE MAXIMUM ALLOWABLE OF 25", THE HEIGHT

TO OPERABLE PARTS SHALL BE 44" MAX.

7. CONTRACTOR IS RESPONSIBLE FOR COORDINATING THAT MAXIMUM DIMENSIONS ARE NOT TO BE EXCEEDED AND MINIMUM CLEARANCES ARE NOT LESS

THAN THE MINIMUM DIMENSIONS LISTED.

18" MIN

SD

PTD

R E

F L

S

U R

F A

C E

M

A X

T O

MI-S

M A

X

M A

X

ACC UR

(ACCESSIBLE

URINAL)

13.5" MIN

UR

(URINAL)

M A

X

SR

(SHOWER

ROD)

MR & SSK

(MOP RACK & MOP SINK)

M A

X

SHOWER

CONTROL

VALVE

SST

(SHOWER

SEAT)

M

IN

M A

X

O T

H E

R S

CH

(COAT HOOK)

A C

C E

S S

IB

L E

MOP

RACK

SD

(SOAP

DISPENSER)

PTD

(PAPER

TOWEL

DISPENSER)

PTD/WR

(PAPER TOWEL

DISPENSER /

WASTE

RECEPTACLE)

MI-S / MI

(MIRROR STAINLESS

/ MIRROR)

HAND

DRYER

O U

T L

E T

M

IN

T

O

TPH

(TOILET

PAPER

HOLDER)

TSCD

(TOILET SEAT

COVER

DISPENSER)

A

F F

ALL OPERATING MECHANISMS SHALL BE NO

HIGHER THAN 3'-4" ABOVE FINISHED FLOOR AT

ACCESSIBLE TOILET ROOMS

C A

B

IN

E T

A N

D F

.E H

A N

D L

E

M

A X

T O

A L L

O P

E R

A B

L E

P A

R T

S O

F

FEC

(FIRE

EXTINGUISHER

CABINET)

INSULATE

ALL SUPPLY

AND DRAIN

PIPES, TYP

M

IN

8" MIN

ACC LAV

ELEVATION

M

IN

M

IN

ACC SINK

ELEVATION

8" MIN

M

IN

11" MIN

INSULATE

EXPOSED

SUPPLY AND

DRAIN PIPES

WHERE

OCCURS

11" MIN M

IN

MIN

24"

MIN

12"

M

IN

M

A X

5'-0" MIN CLR

T O

P O

F G

B

T O

V A

L V

E B

U T

T O

N

M A

X

GB42

FIN. FACE

OF WALL

24" MIN

4'-0" MIN

7"-9"

STPH OR

TPH

GB48

WC

PTN

(WATER CLOSET

PARTITION)

54" MIN

18" MAX

17" MIN

FACE OF

WALL OR

EDGE OF

LAV

12" MAX

FIN. FACE OF WALL

WHERE OCCURS

T O

P O

F G

B

T O

ACC WC

(ACCESSIBLE

WATER CLOSET)

ACC WC

(ACCESSIBLE

WATER CLOSET)

SANITARY

NAPKIN

DISPOSAL,

ADJACENT

TO TPH - 19"

AFF MAX TO

OPENING

T O

A L L

O P

E R

A B

L E

P A

R T

S

M A

X

HSD

(HAND

SANITIZER

DISPENSER)

FLEX SHOWER

SPRAY HOSE 59"

MIN LENGTH

ACCESSIBILITY CLEARANCES

0500_0100_ACC CLEARANCES_01

171108

T O

IL

E

T S

C

L R

(W A

L L

M T

D

5'-0" CLR

C L

R

A

3'-0"

O F

T A

B L E

F U

L L L

E N

G T

H

2'-6"

M

IN

TYPICAL TOILET

CLEARANCE

EXAM TABLE

CLEARANCE

30" X 48"

CLEAR FLOOR

WHEELCHAIR

SPACE

TYPICAL SINK

CLEARANCE

TYPICAL

LAVATORY

CLEARANCE

5'-0" CLEARANCE

CIRCLE

T-SHAPED

TURNING SPACE

REFRIGERATOR /

FREEZER PARALLEL

APPROACH

TYP STORAGE LOCKERS

(FORWARD APPROACH

SHOWN)

PROVIDE CLEARANCE AT BOTH

SIDES OF TABLE IN

EXAMINATION, DIAGNOSTIC

AND TREATMENT ROOMS.

GENERAL NON-EMERGENCY

EXAM ROOMS PROVIDE

CLEARANCE ON ONE SIDE PER

CBC 11B-805.4.1

2'-6" 2'-6"

M

IN

M A

X ø 5'-0

60" MIN

M

IN

M

IN

M

IN

NOTE:

FOR REQUIRED KNEE / TOE

CLEARANCES @

ACCESSIBLE SINK /

LAVATORY LOCATIONS,

SEE

4'-0"

24" MAX

REF

FRZ

NOTE:

'A' DESIGNATES ACCESSIBLE LOCKER.

THIS LOCKER SHALL HAVE OPERABLE

PARTS THAT ARE EASY TO GRASP WITH

ONE HAND THAT DO NOT REQUIRE

TIGHT GRASPING, PINCHING, OR

TWISTING OF THE WRIST TO OPERATE.

ALL OPERABLE PARTS, INTERIOR

HOOKS, AND SHELVES SHALL BE 48"

MAX. AFF. THERE MUST ALSO BE A

SHELF NO LOWER THAN 15" AFF. PER

CBC 11B-308 AND CBC 11B-309.4

FIXED

ACCESSIBLE

BENCH

2'-6"

48" MIN

D E

E P

M

IN

D E

E P

M A

X F

R O

M W

A L L

/2

M A

X

2 1/2" MAX

M

A X

M

IN

M

IN

M A

X

ACCESSIBLE

BENCH

ELEVATION (NTS)

MIN

12" 36" MIN

MIN

12"

2'-6"

GA522

GRAB BAR MOUNTING

0500_0100_GRAB BAR MOUNTING_01

1 1/2" SST TUBING

GRAB BAR

WALL, SEE PLAN

FOR TYPE

ESCUTCHEON PLATE

WOOD STUD

(3) #12 PAN HEAD WOOD

SCREWS W/ 1 1/2" MIN

EMBED INTO TYPE C

BACKING

FOR MOUNTING HEIGHTS SEE

1 1/2"

M

IN

M

IN

/2

PROJECTION FROM WALL

PROJECTION FROM

WALL, SEE

GA521

GA541

APPROVAL OF THIS PLAN DOES NOT

AUTHORIZE OR APPROVE ANY OMISSION OR

DEVIATION FROM APPLICABLE REGULATIONS.

FINAL APPROVAL IS SUBJECT TO FIELD

INSPECTION. ONE SET OF APPROVED PLANS

SHALL BE AVAILABLE ON THE PROJECT SITE

AT ALL TIMES.

OFFICE OF THE STATE FIRE MARSHAL

APPROVED FIRE AND PANIC ONLY

REVIEWED BY:

DATE:

1 2 3 4 5

D

C

B

A

SHEET

TITLE

MANAGEMENT

ISSUED

PROJECT

SEAL

CLIENT PROJECT NO:

LIONAKIS PROJECT NO:

IF

T

H

IS

S H

E E

T

IS

N O

T

0" x4

2" , I

E

D U

C E

D P

R

IN

T

S C

A

LE

A C

C O

R D

IN

REAL ESTATE SERVICE DIVISION

PROJECT MANAGEMENT &

DEVELOPMENT BRANCH

AGENCY

DGS PROJECT # DGS000000004638

CONSULTANT

ARCHITECT

/1

2/

:3 2:

A

M A ut od es k

D oc s:

//2

.0

W as hi ng to n

S tr ee t T

I/2

.0

1_ A

R C

H M

S T

E R

_A _R

_C

E N

T R

A L.

rv t

GA521

DETAILS - INTERIOR -

ACCESSIBILITY

21077.01

?00.00.00?

TENANT IMPROVEMENT

60 NORTH WASHINGTON STREET

SONORA, CA 95370

2 SOUTH GREENE ST., SONORA, CA

ISSUED FOR PERMIT SET - 100% CD

SEPTEMBER 8, 2023

1/4" = 1'-0"10

1/4" = 1'-0"20

2025 Nineteenth Street Sacramento CA 95818 P 916.558.1900 F 916.558.1919 www.lionakis.com

3" = 1'-0"16

C18997

L

IC

ENSED A

T

RCHITEC

R 3EN. 0 -28- 2

S

AT

A

T E

OF C A L I FO

R N

I

UOCOD

OH

SCI

N

LAS

ASI-001 MM/DD/YYYY ASI DESCRIPTION

HI-LO DRINKING FOUNTAIN -

WING WALLS

0500_0100_DF WING WALLS_01

A L C

O V

E

P T

H S

P

L A

N S

WING WALL AS

OCCURS SEE

FLOOR PLANS

CENTER OF BUBBLER

OUTLET & CONTROLS

6" FROM FRONT OF DF

ACCESSIBLE DRINKING

FOUNTAIN 18" MIN, 19"

MAX DEPTH

M

IN

O F

B U

B B

L E

R

M

A X

T O

C T

R

MIN

16"

CLMIN

16"

CL

OF DF

DEPTH

M

A X

TYPICAL ELEVATION TYPICAL SIDE ELEVATION

AT WING WALL

WING WALL,

SEE PLANS

FOR

LOCATIONS

TYPICAL PLAN

CLEAR

FLOOR

SPACE

30x48

CENTERED

ON LOW DF

VARIES, SEE PLAN

MIN

8"

MAX

6"

M

IN9

DEPTH

17" MIN

M

IN

WING WALLS,

SEE PLANS

D E

P T

H O

F

F

O R

Q1

ACCESSIBLE URINAL REQUIREMENTS

0500_0100_TYP URINAL ACCESS REQ_01

?YYMMDD?.

M A

X

M A

X

RIM PROJECTION

13 1/2" MIN

M A

X

M A

X

36" CLR

30" CLR 48" CLR

15" MIN

X<24"

C

L R

X

C

L R

48" CLR

X

X>24"

48" CLR

CL

30" X 48" MIN CLR REQUIREMENTS 36" X 48" MIN CLR REQUIREMENTS REQUIRED SINK CLEAR SPACE

AT WALL MOUNTED OBJECTS

0500_0100_REQ SINK CLEAR SPACE AT WALL MOUNTED OBJECTS_01

M

IN

1'-4"

BASED ON 9" TOE

SPACE HEIGHT

AND 1:6 KNEE

SPACE SLOPE

/2

M

IN

PER 11B-306.2.2

25" MAX

6" MAX

TOE SPACE

DEPTH PER

11B-306.2.4

SOAP, TOWEL, SWITCH, OUTLET, OR OTHER

OPERABLE PART ON WALL. 44" MAX. HEIGHT

PER 11B-308.2.2

NOTE: NOTHING CAN BE MOUNTED ON

THE BACK WALL UNLESS THE PROVIDED

TOE SPACE ALSO EXTENDS TO THE BACK

WALL PER 11B-308.2.2

NO PIPES, PLUMBING

FITTINGS, OR OTHER

INTRUSIONS

ALLOWED PAST

DASHED LINE

1'-7"

REMAINDER MUST BE KNEE

SPACE PER 11B-306.3

CLEARANCE AT LAVATORY

COUNTER

0500_0100_CLEARANCE AT DEEP LAVATORY_01

T O

E S

P A

C E

M

IN

C

L R

CLR TOE SPACE

6" MAX

MAX

3"

(SEE NOTE)

8"-10"

KNEE SPACE

1" 5

(SEE NOTE)

17"-19"

PLANE OF WALL

SOLID SURFACE

COUNTER AND

BACKSPLASH

O R

L A

V R

IM

T O

C O

U N

T E

R T

O P

M

A X

M

IN

M

IN

NOTE:

KNEE SPACE

CORRESPONDS W/

LAVATORY

COUNTER DEPTH.

IF LAV IS 17" DEEP,

THEN KNEE SPACE

MUST BE AT LEAST

8" ETC.

REACH OVER OBSTRUCTION

0500_0100_REACH OVER_01

?YYMMDD?

6"VARIES

(SEE NOTE)

19" MIN TOE SPACE DEPTH

(SEE NOTE)

25" MAX REACH DEPTH

FINISH FACE OF

WALL WITH

ELECTRICAL

RECEPTACLES OR

SWITCH

ALLOWABLE KNEE

SPACE

REDUCTION AT

PLUMBING

FIXTURES SEE

NOTE:

TOE SPACE MUST

BE EQUAL TO, OR

GREATER THAN

REACH DEPTH

M

IN

A T

L A

V A

T O

R

IE

S

M

IN

A

T W

O R

K C

O U

N T

E R

S A

N D

S

IN

K S

M

IN

GA522

GA522

MIN LAVATORY KNEE/TOE

CLEARANCE

0500_0100_MIN LAVATORY KNEE/TOE CLEARANCE_01

(SEE NOTE)

8"-10"

KNEE SPACE

(SEE NOTE)

17"-19"

M

IN

A T

F R

O N

T A

P R

O N

M

IN 3

M A

X

TOE SPACE

6" MAX CLR

3" MAX

T O

E S

P A

C E

M

IN

C

L R

NOTE:

KNEE SPACE CORRESPONDS

W/LAVATORY FIXTURE

DEPTH. IF LAV IS 17" DEEP,

THEN KNEE SPACE MUST BE

AT LEAST 8" ETC.

ACCESSIBLE STALL

REQUIREMENTS

0500_0100_ACC STALL REQ_01

A

B

B

B

AT END OPENING, IN SWINGING DOOR

60" MIN @ SIDE OPENING DOOR OR

48" MIN @ END OPENING, OUT SWING DOOR

A

B

M

IN

M

IN

MOUNTED WC

59" MIN AT FLOOR

MOUNTED WC

56" MIN AT WALL

M

IN

M A

X

4" MAX

NOTES:

1. PROVIDE A TOE CLEARANCE OF 9 INCHES MINIMUM

ABOVE THE FINISH FLOOR.

2. COMPARTMENTS FOR CHILDREN'S USE SHALL

PROVIDE A TOE CLEARANCE OF 12 INCHES MINIMUM

ABOVE THE FINISHED FLOOR.

3. WHERE PARTITION TOE CLEARANCES ARE LESS THAN

THE ABOVE DIMENSIONS 66" CLEAR STALL IS REQUIRED.

NOTE:

PROVIDE SELF CLOSING

HINGES, LATCH AND DOOR

PULLS ON BOTH SIDES OF

THE DOOR NEAR THE LATCH.

34" MIN

M

IN

M

IN

C

L R

17" MIN

18" MAX 18" MIN

60" MIN CLR SPACE

WC

LAV.FLUSH VALVE

ON WIDE SIDE

48" GRAB BAR

60" MIN DIA CLR

12" M

AX

S E

E F

L O

O R

P L

A N

SEE FLOOR PLAN

M

IN

30"x48" CLR

SPACE

ACCESSIBLE TOILET ROOM

CLEARANCES - SINGLE

ACCOMMODATION

0500_0100_ACC RR CLEARANCES SINGLE_01

FOF

REQD DOOR

CLEARANCE

, SEE DETAIL

F O

F

L O

N G

E S

T W

C

A S

S U

M E

D

CL

42" GRAB BAR

CL

GA541

M

IN

C

L R

60" CLR

42" MIN

12"

MAX

54" MIN

GRAB BAR

NO PROJECTIONS

WITHIN 12" ABOVE

GRAB BAR OR WITHIN

1 1/2" BELOW OR AT

ENDS OF GRAB BAR

TPD

FINISH FLOOR

CL

7"-9" FROM

FRONT OF

TOILET

19" MIN TO

DISPENSING

POINT

M A

X

M

IN

ACCESSIBLE WATER CLOSET

REQUIREMENTS - SIDE

0500_0100_ACC WATER CLOSET REQ SIDE_01

TOILET SEAT

COVERS

SANITARY NAPKIN

DISPOSAL

T O

P O

F O

P E

N

IN

G

T O

O P

E N

IN

G

A F

F M

A X

42" MIN

12" MIN 24" MIN

17" MIN

18" MAX

M A

X

M

IN

FINISH FLOOR

NO PROJECTIONS

WITHIN 12" ABOVE

GRAB BAR OR 1 1/2"

BELOW OR AT ENDS

OF GRAB BAR

36" MIN REAR

GRAB BAR

ACCESSIBLE WATER CLOSET

REQUIREMENTS - FRONT

0500_0100_ACC WATER CLOSET REQ FRONT_01

APPROVAL OF THIS PLAN DOES NOT

AUTHORIZE OR APPROVE ANY OMISSION OR

DEVIATION FROM APPLICABLE REGULATIONS.

FINAL APPROVAL IS SUBJECT TO FIELD

INSPECTION. ONE SET OF APPROVED PLANS

SHALL BE AVAILABLE ON THE PROJECT SITE

AT ALL TIMES.

OFFICE OF THE STATE FIRE MARSHAL

APPROVED FIRE AND PANIC ONLY

REVIEWED BY:

DATE:

1 2 3 4 5

D

C

B

A

SHEET

TITLE

MANAGEMENT

ISSUED

PROJECT

SEAL

CLIENT PROJECT NO:

LIONAKIS PROJECT NO:

IF

T

H

IS

S H

E E

T

IS

N O

T

0" x4

2" , I

E

D U

C E

D P

R

IN

T

S C

A

LE

A C

C O

R D

IN

PROJECT MANAGEMENT &

DEVELOPMENT BRANCH

AGENCY

DGS PROJECT # DGS000000004638

CONSULTANT

ARCHITECT

/1

2/

:3 2:

A

M A ut od es k

D oc s:

//2

.0

W as hi ng to n

S tr ee t T

I/2

.0

1_ A

R C

H M

S T

E R

_A _R

_C

E N

T R

A L.

rv t

GA522

DETAILS - INTERIOR -

ACCESSIBILITY

21077.01

?00.00.00?

TENANT IMPROVEMENT

60 NORTH WASHINGTON STREET

SONORA, CA 95370

2 SOUTH GREENE ST., SONORA, CA

ISSUED FOR PERMIT SET - 100% CD

SEPTEMBER 8, 2023

3/8" = 1'-0"3

1/2" = 1'-0"8 1" = 1'-0"16

1 1/2" = 1'-0"14

1 1/2" = 1'-0"15

1 1/2" = 1'-0"133/8" = 1'-0"9

3/8" = 1'-0"12

1/2" = 1'-0"11

1/2" = 1'-0"10

2025 Nineteenth Street Sacramento CA 95818 P 916.558.1900 F 916.558.1919 www.lionakis.com

C18997

L

IC

ENSED A

T

RCHITEC

R 3EN. 0 -28- 2

S

AT

A

T E

OF C A L I FO

R N

I

UOCOD

OH

SCI

N

LAS

'X

4" MAX IF 'X' > 27"

'P'

'X

PROVIDE CANE

DETECTABLE

ELEMENT

IF 'P' > 4" AND 'X' > 27"

PROTRUDING OBJECTS

0500_0100_PROTRUDING OBJECTS_01

?YYMMDD?

M

IN

PROTRUDING

OBJECT

PROTRUDING

OBJECT

FINISHED FLOOR

ACCESSIBLE HANDRAIL AT WALL

0500_0100_ACC HNDRL AT WALL_01

NOT TO SCALE

" 1'-0"

DEPTH

TREAD

4'-0" MAX

SPACING OF WALL

MTD BRACKETS

LANDING

FIN. LANDING

1'-0"

1 1/2" OD 13 GA TUBE

WALL MOUNTED BRACKET

ATTACHMENT VARIES

WALL CONSTRUCTION

INSIDE FACE OF

STAIR CORE WALL

PLAN

ELEVATION

/2

C L

R

WHERE WALL IS ROUGH

OR ABRASIVE (SUCH AS

CONCRETE OR

STUCCO) PROVIDE

METAL PROTECTION

PLATE

1'-0"

M

IN

M A

X

DOOR HANDLE/

PANIC HARDWARE

WHERE OCCURS

U N

O B

S T

R U

C T

E D

M A

X

M

IN

U

O N

SWITCHES

CONVENIENCE

WALL OUTLET

THERMOSTAT

FIRE ALARM

KICK PLATE

ACCESSIBLE MOUNTING HEIGHT

REQUIREMENTS

0500_0100_ACC MOUNTING HEIGHT REQ DOOR_01

?YYMMDD?

FINISHED

FLOOR

S M

O O

T H

U

N

IN

T E

R R

U P

T E

D S

U R

F A

C E

M

IN

F U

L L

W

ID

T H

O F

D O

O R

PUSH SIDE

ACCESSIBLE DOOR SURFACE

REQUIREMENT

0500_0100_ACC DOOR SURFACE REQ_01

DOOR OTHER THAN

SLIDING DOOR IN

ACCESSIBLE PATH OF

TRAVEL

/4

M

A X

/2

M

A X

/4

M

A X

CARPET WILL NOT EXCEED 1/2"

HIGH PILE WHERE INSTALLED

CARPET TO BE PERMANENTLY

AND SECURELY AFFIXED TO

FLOOR

MAXIMUM HEIGHTS AT ALL

THRESHOLDS

MAXIMUM HEIGHT AT SLOPED

LEVEL CHANGE

MAXIMUM HEIGHT AT LEVEL

CHANGE WITH NO

TRANSITION

/2

M

A X

FLOORING TRANSITION

0500_0100_FLOORING TRANSITIONS_01

MAX

MAX

/4

M

A X

/4

M

IN

M

IN

M

IN

P U

L L S

ID

E

P U

S H

S

ID

E

C L

X

T E

R

IO

O R

C L

IN

E R

IO

O

R

CLEAR SPACE FINISH

ELEVATION TO MATCH

FINISH FLOOR ELEVATION

AT DOOR

PROVIDE THIS ADDITIONAL

SPACE IF DOOR IS EQUIPPED

WITH A LATCH AND A CLOSER

C L E

A R

O P

E N

IN

G

M

IN

5'-0" 4'-0"

FRONT APPROACH DOOR CLEARANCES, TYP

44" MIN 60" MIN

M

IN

C L E

A R

O P

E N

IN

G

M

IN

M

IN

48" MIN IF DOOR HAS A

LATCH AND CLOSER

HINGE APPROACH DOOR CLEARANCES, TYP

PUSH SIDE

PULL SIDE

PULL SIDEPUSH SIDE

44" MIN 60" MIN

M

IN

C L E

A R

O P

E N

IN

G

M

IN

48" MIN IF DOOR HAS A

CLOSER

LATCH APPROACH DOOR CLEARANCES, TYP

NOTE: AREA MUST NOT EXCEED A SLOPE OF 2% IN ANY DIRECTION

ACCESSIBLE DOOR CLEARANCES

0500_0100_ACC DOOR CLEARANCES_01

WHERE AN OBSTRUCTION IS

MORE THAN 8", PROVIDE

THE NOTED CLEAR SPACE

M

IN

ACCESSIBLE DOOR HARDWARE

REQUIREMENTS

0500_0100_ACC DOOR HARDWARE REQ_01

HAND-ACTIVATED DOOR OPENING

HARDWARE, HANDLES, PULLS,

LATCHES. LOCKS AND OTHER

OPERATING DEVICES ON ACCESSIBLE

DOORS SHALL HAVE A SHAPE THAT IS

EASY TO GRASP WITH ONE HAND AND

DOES NOT REQUIRE TIGHT GRASPING.

TIGHT PINCHING OR TWISTING OF THE

WRIST TO OPERATE.

LATCHING AND LOCKING DOORS THAT

ARE HAND-ACTIVATED AND WHICH ARE

IN ACCESSIBLE ROUTE, SHALL BE

OPERABLE WITH A SINGLE EFFORT BY

LEVER-TYPE HARDWARE, PANIC BARS

OR OTHER HARDWARE DESIGNED TO

PROVIDE PASSAGE. LOCKED EXIT

DOORS SHALL OPERATE AS ABOVE IN

EGRESS DIRECTION.

LEVER

LOOP

PUSH

1.

2.

1. MINIMUM CLEAR FLOOR OR GROUND SPACE REQUIRED TO ACCOMMODATE A

SINGLE, STATIONARY WHEELCHAIR AND OCCUPANT IS 30 INCHES BY 48 INCHES.

MINIMUM CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS MAY BE

POSITIONED FOR FORWARD OR PARALLEL APPROACH TO AN OBJECT, UNLESS

RESTRICTED BY CODE. FLOOR OR GROUND SPACE FOR WHEELCHAIRS MAY BE

PART OF THE KNEE SPACE REQUIRED UNDER SOME ELEMENTS AS ALLOWED BY

CODE.

2. PROVIDE A MINIMUM CLEAR SPACE 60 INCHES WIDE AT ALCOVES GREATER THAN

15 INCHES DEEP AND DESIGNED FOR SIDE APPROACH.

3. PROVIDE A MINIMUM CLEAR SPACE 36 INCHES WIDE AT ALCOVES GREATER THAN

24 INCHES DEEP AND DESIGNED FOR FRONT APPROACH.

CLEAR FLOOR SPACE FOR WHEELCHAIRS

1. OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES BETWEEN 27 INCHES AND 80 INCHES ABOVE THE FINISHED FLOOR SHALL PROTRUDE NO MORE THAN 4" INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES.

2. OBJECTS MOUNTED WITH THEIR LEADING EDGES AT OR BELOW 27 INCHES ABOVE THE

FINISHED FLOOR MAY PROTRUDE ANY AMOUNT.

3. FREE-STANDING OBJECTS MOUNTED ON POSTS / PYLONS MAY OVERHANG 12 INCHES MAXIMUM

FROM 27 INCHES TO 80 INCHES ABOVE THE GROUND OR FINISHED FLOOR.

4. PROTRUDING OBJECTS SHALL NOT REDUCE THE REQUIRED CLEAR WIDTH OF AN ACCESSIBLE

ROUTE OR MANEUVERING SPACE.

5. ANY OBSTRUCTION OVERHANGING A PEDESTRIAN WAY SHALL BE A MINIMUM OF 80 INCHES

ABOVE THE WALKING SURFACE AS MEASURED TO THE BOTTOM OF THE OBSTRUCTION.

HAZARDOUS AND PROJECTING OBJECTS

1. SURFACE SLOPES OF ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL NOT EXCEED

1/4 INCH PER FOOT (2% GRADIENT) IN ANY DIRECTION.

2. ACCESSIBLE PARKING SPACES SHALL BE LOCATED SO AS NOT TO REQUIRE USERS TO TRAVEL

OR WALK BEHIND ANY PARKING SPACE OTHER THAN THEIR OWN.

3. IN EACH PARKING AREA, A BUMPER OR CURB SHALL BE PROVIDED AND LOCATED TO PREVENT

ENCROACHMENT OF CARS OVER THE REQUIRED WIDTH OF WALKWAYS.

4. PARKING SPACES RESERVED FOR PERSONS WITH DISABILITIES SHALL BE IDENTIFIED BY A

REFLECTORIZED SIGN PERMANENTLY POSTED IMMEDIATELY ADJACENT TO AND VISIBLE FROM

EACH STALL OR SPACE CONSISTING OF A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT,

IN WHITE ON DARK BLUE BACKGROUND. THE SIGN SHALL NOT BE SMALLER THAN 70 INCHES IN

AREA AND, WHEN IN AN ACCESSIBLE ROUTE, SHALL BE POSTED AT A MINIMUM HEIGHT OF 80

INCHES FROM THE BOTTOM OF THE SIGN TO THE PARKING SPACE FINISHED GRADE. SIGNS

MAY ALSO BE MOUNTED ON THE WALL AT THE INTERIOR END OF THE PARKING SPACE AT A

MINIMUM HEIGHT OF 60 INCHES FROM THE PARKING SPACE FINISHED GRADE, GROUND, OR

WALK.

PARKING

1. THE INFORMATION DEPICTED ON THIS SHEET REPRESENT BUILDING CODE

REQUIREMENTS. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES

ON THIS PROJECT THAT WOULD CREATE A CONFLICT WITH THE PLANS OR

ACCESS REQUIREMENTS.

DISCREPANCIES

ACCESSIBLE ROUTE NOTES

0500_0100_ACC ROUTE NOTES_01

?YYMMDD?

1. IN NEW CONSTRUCTION, ALL PRIMARY ENTRANCES AND EXTERIOR GROUND FLOOR EXIT

DOORS TO BUILDINGS AND FACILITIES SHALL BE ACCESSIBLE TO THE DISABLED.

2. IN EXISTING BUILDINGS WHERE NOT ALL ENTRANCES ARE ACCESSIBLE, ALL ACCESSIBLE

ENTRANCES SHALL BE IDENTIFIED WITH AT LEAST ONE STANDARD INTERNATIONAL SYMBOL

OF ACCESSIBILITY SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE

FROM APPROACHING PEDESTRIAN WAYS.

3. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE OF A SIZE AS TO PERMIT

THE INSTALLATION OF A DOOR NOT LESS THAN 36 INCHES IN WIDTH, AND NOT LESS THAN

80 INCHES IN HEIGHT. DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND

SHALL BE MOUNTED SO THAT THE CLEAR WIDTH THE DOORWAY IS NOT LESS THAN 32

INCHES.

4. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE PART OF AN

ACCESSIBLE ROUTE OR SPACE, SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER

TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS. OR OTHER HARDWARE

DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE

OPENING HARDWARE.

5. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 34 INCHES

MINIMUM AND 44 INCHES MAXIMUM ABOVE THE FLOOR.

6. THE FLOOR OR LANDING LENGTH ON EACH SIDE OF AN ENTRANCE OR A PASSAGE DOOR

SHALL BE LEVEL AND CLEAR AT LEAST 60 INCHES IN THE DIRECTION OF THE DOOR SWING

AND AT LEAST 48 INCHES OPPOSITE THE DIRECTION OF THE DOOR SWING AS MEASURED

AT RIGHT ANGLES TO THE FACE OF THE DOOR IN THE CLOSED POSITION. THE WIDTH OF

THE LEVEL AND CLEAR AREA ON THE SIDE WHICH THE DOOR SWINGS SHALL EXTEND A

MINIMUM OF 24 INCHES PAST THE STRIKE EDGE OF THE DOOR FOR DOORS WITH LATCH

SIDE APPROACH AND 36 INCHES FOR DOORS REQUIRING HINGE SIDE APPROACH.

7. THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2 INCH LOWER THAN THE

THRESHOLD OF THE DOORWAY. CHANGES IN LEVEL BETWEEN 1/4 INCH AND 1/2 INCH SHALL

BE BEVELED WITH A SLOPE NO GREATER THAN 1:2.

8. THE BOTTOM 10 INCHES OF ALL DOORS (EXCEPT AUTOMATIC AND SLIDING) SHALL HAVE A

SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A

WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION WHERE

NARROW…