Attachment_G-Plans_&_Specifications_for_the_Washington_Street_Building_Remodel_Project.pdf
PDF 45 MB Posted
- Attached to
- Washington Street Building Remodel Project
- Solicitation number
- IFB-2023-0120
- Issued by
- Tuolumne County, Sereno Del Mar CDP, California
About this file
This file contains architectural and engineering plans for the Washington Street Building Remodel Project by Tuolumne County, California. The project involves converting the existing historic Washington Street Courthouse located at 60 North Washington Street in Sonora into new law offices for the county. The comprehensive tenant improvement project includes demolition, architectural modifications, mechanical, electrical, and plumbing upgrades across approximately 5,515 square feet of interior space. The design documents are dated September 8, 2023, and were prepared by Lionakis, a Sacramento-based architectural firm, with engineering support from Capital Engineering Consultants and The Engineering Enterprise.
The project includes two additive alternates: the first involves pressure washing and painting the exterior, while the second involves replacing the entrance canopy on the east side. The renovation will create multiple attorney offices, conference rooms, support spaces, restrooms, and a break room. The plans detail accessibility requirements, ensuring compliance with California Building Code and Americans with Disabilities Act standards. Electrical upgrades include new lighting, power distribution, and lighting control systems, with two existing electrical panels being modified or replaced. The project will maintain the building's existing structural elements and roofing while comprehensively updating the interior to create a modern, functional office environment for the County of Tuolumne's Public Defender's Office.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION
VICINITY MAP
OWNER
COUNTY OF TUOLUMNE
2 SOUTH GREEN STREET
SONORA, CA 95370
CONTACT: ERIC ERHARDT
PHONE: 209-533-5511
EMAIL: EERHARDT@CO.TUOLUMNE.CA.US
MECHANICAL ENGINEER
CAPITAL ENGINEERING CONSULTANTS, INC.
11020 SUN CENTER DRIVE
RANCHO CORDOVA, CA 95670
CONTACT: KEVIN STILLMAN
PHONE: 916-851-3500
EMAIL: KSTILLMAN@CAPITAL-ENGINEERING.COM
ARCHITECT
LIONAKIS
2025 19TH STREET
SACRAMENTO, CA 95818
CONTACT: BRANDON RACHAC
PHONE: 916.558.1900
EMAIL: BRANDON.RACHAC@LIONAKIS.COM
STRUCTURAL ENGINEER
LIONAKIS
2025 19TH STREET
SACRAMENTO, CA 95818
CONTACT: ENGINEER CONTACT NAME
PHONE: 916.558.1900
EMAIL: CONTACT EMAIL@LIONAKIS.COM
ELECTRICAL ENGINEER
THE ENGINEERING ENTERPRISE
1125 HIGH STREET
AUBURN, CA 95603
CONTACT: SCOTT WHEELER
PHONE: 530-886-8556
EMAIL: SCOTT@ENGENT.COM
PROJECT DIRECTORY
THE PROJECT CONSISTS OF REMODELING AN EXISTING COUNTY COURTHOUSE INTO NEW LAW
OFFICES.
SCOPE OF PROJECT
REFER TO SHEET GL101 FOR CONSTRUCTION TYPE, OCCUPANCY CLASSIFICATIONS, CODE
ANALYSIS AND LIFE SAFETY FLOOR PLAN.
PROJECT DATA
BUILDING IDENTIFIER - WHERE OCCURS
DISCIPLINE DESIGNATOR - LEVEL 1
DISCIPLINE DESIGNATOR - LEVEL 2
REPLACE DASH WHERE OCCURS
SHEET TYPE SUBSET DESIGNATOR
LEVEL/SEQUENCE DESIGNATOR
AREA IDENTIFIER - WHERE OCCURS
SHEET TYPE DESIGNATOR
C.A-123AB
UNIQUE PORTION IDENTIFIER - WHERE OCCURS
SHEET TYPE DESIGNATORS
0 - GENERAL
1 - PLANS
2 - ELEVATIONS
3 - SECTIONS
4 - LARGE SCALE VIEWS
5 - DETAILS
6 - SCHEDULES & DIAGRAMS
7 - USER DEFINED
8 - USER DEFINED
9 - 3D REPRESENTATIONS
DISCIPLINE DESIGNATORS - LEVEL 1
G GENERAL
H HAZARDOUS MATERIALS
V SURVEY/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
W DISTRIBUTED ENERGY
T TELECOMMUNICATIONS
R RESOURCE
X OTHER DISCIPLINES
Z CONTRACTOR/SHOP DRAWINGS
O OPERATIONS
SHEET IDENTIFICATION LEGEND
ARCHITECTURAL SYMBOLS LEGEND
B3
A-501
B3
A-501
A4
A-201
D2
A-512
TOC 98'-8"
B3
A-301
A2
A-303
A2
A-303
ROOM NAME
NORTH
PLAN
MATCH LINE
SEE XX / X-XXX
A
A-202 A2
A1
A2A4
A3
A-202
LEVEL 1
100'-0"
D2
A-512
D2
A-512
DETAIL INDICATOR - REFERENCE &
DETAIL INDICATOR - ITEM
DETAIL INDICATOR - SECTION & DETAIL
INDICATOR - SECTION ITEM
SECTION INDICATOR - PARTIAL
BUILDING/WALL &
DETAIL INDICATOR - AREA
SECTION INDICATOR - BUILDING
ELEVATION INDICATOR - EXTERIOR
ELEVATION INDICATOR - INTERIOR,
SINGLE & MULTIPLE VIEW
MATCH LINE INDICATOR
REFERENCE GRID WITH REFERENCE GRID LINES
REVISION INDICATOR & REVISION CLOUD
ROOM IDENTIFIER WITH ROOM NAME & NUMBER
ELEVATION INDICATOR - LEVEL & SPOT
WINDOW OR LOUVER IDENTIFIER
KEYNOTE INDICATOR
PLAN NORTH & TRUE NORTH INDICATOR
PROJECT LOCATION
LOCATION MAP
ADD ALTERNATE 1: GENERAL CONTRACTOR TO PRESSURE WASH THE EXTERIOR, PATCH ANY
VOIDS IN EXTERIOR WALLS AND PAINT EXTERIOR PER COLOR CHOSEN BY
THE COUNTY.
ADD ALTERNATE 2: REPLACED ENTRANCE CANOPY ON THE EAST SIDE. COUNTY TO DETERMINE
NAME ON THE CANOPY.
ADDITIVE ALTERNATES
1. FIRE ALARM SYSTEM
DEFERRED SUBMITTALS
1 2 3 4 5
D
C
B
A
SHEET
TITLE
AGENCY
MANAGEMENT
ISSUED
PROJECT
SEAL
CONSULTANT
CLIENT PROJECT NO:
LIONAKIS PROJECT NO:
IF
T
H
IS
S H
E E
T
IS
N O
T
0" x4
2" , I
T
IS
A
R E
D U
C E
D P
R
IN
T
S C
A
LE
A C
C O
R D
IN
G
LY
1/
4"
2"
1"
CLIENT
/1
2/
:3 2:
A
M A ut od es k
D oc s:
//2
.0
W as hi ng to n
S tr ee t T
I/2
.0
1_ A
R C
H M
S T
E R
_A _R
_C
E N
T R
A L.
rv t
G-001
COVER SHEET
60 NORTH WASHINGTON STREET
SONORA, CA 95370
ISSUED FOR PERMIT SET - 100% CD
21077.01
?00.00.00?
COUNTY OF TUOLUMNE
HISTORIC WASHINGTON STREET COURTHOUSE
WASHINGTON STREET COURTHOUSE
SEPTEMBER 8, 2023
TENANT IMPROVEMENT
COUNTY OF TUOLUMNE
TENANT IMPROVEMENT
60 NORTH WASHINGTON STREET
SONORA, CA 95370
2 SOUTH GREENE ST., SONORA, CA
SEE UNITED STATES NATIONAL
CAD STANDARD FOR ANY
ABBREVIATIONS NOT LISTED
BELOW.
& AND
@ AT
(E) EXISTING
' FOOT, FEET
" INCH(ES)
# NUMBER
ALUM ALUMINUM
ARCH ARCHITECTURAL
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT / ENGINEER
AB ANCHOR BOLT
AC ASPHALTIC CONCRETE
ACC ACCESSIBLE
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACST ACOUSTIC
AD AREA DRAIN
ADC AUTOMATIC DOOR CLOSER
ADO AUTOMATIC DOOR OPERATOR
ADDL ADDITIONAL
ADJ SHV ADJUSTABLE SHELVING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AGGR AGGREGATE
AHU AIR HANDLING UNIT
ASSY ASSEMBLY
BD BOARD
BKG BACKING
BLDG BUILDING
BM BEAM
BM BENCHMARK
BOT BOTTOM
BTWN BETWEEN
BUR BUILT-UP ROOFING
BW BOTH WAYS
C CHANNEL
CAB CABINET
CB CATCH BASIN
CBC CALIFORNIA BUILDING CODE
CEM CEMENT
CEM PLAS CEM PLASTER
CFLG COUNTERFLASHING
CFMF COLD-FORMED METAL FRAMING
CG CORNER GUARD
CI CAST IRON
CJ CONSTRUCTION JOINT /
CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNTR COUNTER
CO CLEANOUT
COL COLUMN
CONC CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUE / CONTINUOUS
COTG CLEANOUT TO GRADE
CP CONTROL PANEL
CPT CARPET
CRS COLD ROLLED STEEL
CSK COUNTER SUNK
CSWK CASEWORK
CT CERAMIC TILE
CTR CENTER
DBL DOUBLE
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
LIST OF ARCHITECTURAL ABBREVIATIONS SHEET INDEX
GENERAL
G-001 COVER SHEET
G-002 GENERAL NOTES
GA521 DETAILS - INTERIOR - ACCESSIBILITY
GA522 DETAILS - INTERIOR - ACCESSIBILITY
GA541 DETAILS - DOOR - ACCESSIBILITY
GL111 LIFE SAFETY FLOOR PLAN
ARCHITECTURAL
AD111 DEMOLITION FLOOR PLAN
AD121 DEMOLITION CEILING PLAN
A-111 FLOOR PLAN
A-121 CEILING PLAN
A-131 ROOF PLAN - FOR REFERENCE ONLY
A-141 SIGNAGE FLOOR PLAN & SCHEDULE
A-221 ELEVATIONS - INTERIOR
A-331 SECTIONS - INTERIOR WALL
A-411 LARGE SCALE VIEWS & INT. ELEVATIONS - RESTROOMS
A-521 DETAILS - INTERIOR
A-522 DETAILS - INTERIOR
A-531 PARTITION TYPES & SCHEDULE
A-532 DETAILS - INTERIOR COLD FORMED FRAMING
A-533 DETAILS - INTERIOR COLD FORMED FRAMING
A-541 DETAILS - DOOR FRAME AND WINDOW
A-551 DETAILS - CEILING
A-561 DETAILS - INTERIOR
A-571 DETAILS - SIGNAGE
A-621 SCHEDULES / DIAGRAMS - DOORS
SPEC 05 SPECIFICATIONS - COLD FORMED METAL FRAMING 05 40 00
SPEC 08 SPECIFICATIONS - DOOR HARDWARE 08 71 00
SPEC 08.1 SPECIFICATIONS - DOOR HARDWARE 08 71 00
SPEC 08.2 SPECIFICATIONS - DOOR HARDWARE 08 71 00
SPEC 09 SPECIFICATIONS - GYPSUM BOARD 05 40 00
SPEC 09.1 SPECIFICATIONS - ACOUSTIC PANEL CEILINGS 09 51 13
SPEC 10 SPECIFICATIONS - SIGNAGE 10 14 00
MECHANICAL
M-001 HVAC LEGENDS & NOTES
M-101 HVAC DEMOLITION PLAN
M-201 HVAC PLAN
PLUMBING
P-001 PLUMBING LEGENDS & NOTES
P-002 PLUMBING SCHEDULES
P-101 PLUMBING DEMOLITION PLAN
P-201 PLUMBING PLAN
ELECTRICAL
E-001 SYMBOLS LIST, ABBREVIATIONS, AND SHEET INDEX
E-002 NOTES & SCHEDULES
E-003 TITLE 24
E-130 OVERALL ELECTRCIAL DEMOLITION PLAN
E-230 OVERALL LIGHTING PLAN
E-330 OVERALL POWER PLAN
E-430 OVERALL SPECIAL SYSTEMS PLAN
E-501 POWER ONE LINE DIAGRAM AND DETAILS
2025 Nineteenth Street Sacramento, CA 95818 P 916.558.1900 www.lionakis.com
DHM DETENTION HOLLOW METAL
DIA DIAMETER
DIM DIMENSION
DS DOWNSPOUT
DSP DRY STANDPIPE
DWG DRAWING
DWR DRAWER
EA EACH
EGSB EXTERIOR GYPSUM SHEATHING
BOARD
EIFS EXTERIOR INSULATION AND
FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC / ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
EPB ELECTRICAL PANEL BOARD
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXST EXISTING
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FB FLAT BAR
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FLG FLOORING
FLL FLOW LINE
FLR FLOOR
FOC FACE OF CONCRETE/CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FOW FACE OF WALL
FP FIREPROOF
FRP FIBERGLASS REINFORCED
PLASTIC
FT FEET / FOOT
FTG FOOTING
FURG FURRING
FUT FUTURE
G GROUND; NATURAL GAS
GA GAGE
GALV GALVANIZED
GB GRAB BAR
GI GALVANIZED IRON
GLU LAM GLUED LAMINATED WOOD
GYP GYPSUM
HB HOSE BIB
HC HOLLOW CORE
HDBD HARDBOARD
HDW HARDWARE
HDWD HARDWOOD
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
JAN JANITOR
KIT KITCHEN
L ANGLE
LAB LABORATORY
LAV LAVATORY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MR MOISTURE RESISTANT
MTD MOUNTED
MTL METAL
MULL MULLION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O/ OVER
OC ON CENTER
OD OUTSIDE DIAMETER
OF/CI OWNER FURNISHED /
CONTRACTOR INSTALLED
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
PAF POWER ACTUATED FASTENER
PL PROPERTY LINE; PLATE
PLAM PLASTIC LAMINATE
PLB PLUMB
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT; PAINT
PTN PARTITION
PV PHOTOVOLTAIC
QT QUARRY TILE
R RADIUS; RISER
RD ROOF DRAIN
REBAR REINFORCING STEEL BAR
REF REFERENCE
REF REFRIGERATOR
REINF REINFORCE / REINFORCING
REQD REQUIRED
RESIL RESILIENT
RM ROOM
RO ROUGH OPENING
RWD REDWOOD
RWL RAIN WATER LEADER
SAD SEE ARCHITECTURAL
DRAWINGS
SATC SUSPENDED ACOUSTICAL TILE
CEILING
SB SPLASH BLOCK
SC SOLID CORE
SCHED SCHEDULE
SD STORM DRAIN
SDST SELF DRIVING, SELF TAPPING
SHT SHEET
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SLNT SEALANT
SM SHEET METAL
SPEC SPECIFICATION
SQ SQUARE
SS SANITARY SEWER; SERVICE
SINK
SST STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP CLG SUSPENDED CEILING
SV SHEET VINYL
SYMM SYMMETRICAL
SYS SYSTEM
T TREAD
T&G TONGUE & GROOVE
TEL TELEPHONE
THK THICKNESS
TMH TOP OF MANHOLE
TMPD TEMPERED
TO TOP OF
TOC TOP OF CURB
TOF TOP OF FRAME
TOJ TOP OF JOIST
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF STEEL
TOW TOP OF WALL
TV TELEVISION
TYP TYPICAL
UC UNDER COUNTER/CABINET
UNO UNLESS NOTED OTHERWISE
UON UNLESS OTHERWISE NOTED
UR URINAL
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WH WATER HEATER
WO WHERE OCCURS
WP WORKING POINT
WPM WATERPROOF MEMBRANE
WSCT WAINSCOT
WT WEIGHT
WTR WATER
WWR WELDED WIRE
REINFORCEMENT
C27266
L
IC
ENSED A
T
RCHITEC
R 5EN. 0 -30- 2
S
AT
A
T E
OF C A L I FO
R N
I
Y E
VADJ.LEAH
CI
M
MARK DATE DESCRIPTION
1 2 3 4 5
D
C
B
A
SHEET
TITLE
AGENCY
MANAGEMENT
ISSUED
PROJECT
SEAL
CONSULTANT
CLIENT PROJECT NO:
LIONAKIS PROJECT NO:
IF
T
H
IS
S H
E E
T
IS
N O
T
0" x4
2" , I
E
D U
C E
D P
R
IN
T
S C
A
LE
A C
C O
R D
IN
/1
2/
:3 2:
A
M A ut od es k
D oc s:
//2
.0
W as hi ng to n
S tr ee t T
I/2
.0
1_ A
R C
H M
S T
E R
_A _R
_C
E N
T R
A L.
rv t
G-002
GENERAL NOTES
21077.01
?00.00.00?
COUNTY OF TUOLUMNE
TENANT IMPROVEMENT
60 NORTH WASHINGTON STREET
SONORA, CA 95370
2 SOUTH GREENE ST., SONORA, CA
2025 Nineteenth Street Sacramento, CA 95818 P 916.558.1900 www.lionakis.com
GENERAL NOTES
1. ALL CONSTRUCTION SHALL CONFORM TO THE MINIMUM STANDARDS OF THE 2022 EDITION OF
THE CALIFORNIA BUILDING CODE (C.B.C.) AND THE REQUIREMENTS OF TITLE 24 CALIFORNIA
CODE OF REGULATIONS.
2. THE CONTRACTOR SHALL OBTAIN AND MAINTAIN AT THEIR EXPENSE ALL NECESSARY PERMITS
AND LICENSES FOR THE COMPLETION OF THIS JOB.
3. THE CONTRACTOR SHALL VISIT THE PREMISE WHERE THIS WORK IS TO BE PERFORMED AND
VERIFY ALL SITE CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION.
4. DIMENSIONS ARE GIVEN TO FACE OF EXISTING SURFACES, CMU, OR CONCRETE AND TO THE
FACE OF STUDS UNLESS NOTED OTHERWISE.
5. HEIGHT DIMENSIONS ARE GIVEN TO THE FINISH FLOOR LINE EXCLUSIVE OF FLOOR COVERING.
6. VERIFY DIMENSIONS AND LOCATIONS OF ALL OPENINGS, BASES, ETC., AND SPECIAL
PROVISIONS REQUIRED FOR EQUIPMENT, DUCTS, PIPING, CONDUITS, FINISH HARDWARE, ETC.
7. AT OPENINGS PLACE FLOORING TRANSITION STRIPS UNDER CENTERLINE OF DOOR. WHERE
ADJOINING ROOMS HAVE COMPOSITION OF DIFFERENT COLORS, PLACE STRIP AS NOTED ON
FINISH FLOOR PLAN.
8. THE CONTRACTOR SHALL PROVIDE DUST-PROOF BARRIERS AT OPENINGS INTO ADJACENT
ROOMS AND FINISH AREAS AND WILL LEAVE WORK AREA IN A NEAT AND ORDERLY FASHION AT
THE END OF EACH WORKING DAY. DUST PROTECTION HALL BE CONSTRUCTED FROM
MATERIALS APPROVED BY THE CALIFORNIA STATE FIRE MARSHAL.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES TO THE EQUIPMENT,
FURNITURE OR PREMISES INCURRED AS A RESULT OF WORK INCURRED HEREIN. ANY SUCH
DAMAGES SHALL BE REPAIRED TO THE OWNERS SATISFACTION AT NO INCREASE IN THE
CONTRACT AMOUNT.
10. ALL GLASS DOORS, SIDELIGHTS, AND GLAZED OPENINGS WITHIN 18 INCHES OF THE FLOOR OR
WITHIN 24 INCHES HORIZONTAL OF ANY DOOR OPENING SHALL BE FULLY TEMPERED GLASS
APPROVED FOR IMPACT HAZARD.
11. UNLESS DIMENSIONED OTHERWISE, DOOR RETURNS AT THE HINGE SIDE SHALL BE A MINIMUM
OF 4" FROM THE ADJACENT WALL.
12. THE CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL ACCESS PANELS REQUIRED
IN WALLS AND CEILINGS, POWER, LIGHTING, SWITCHING, COORDINATION OF FIRE ALARM AND
LIFE SAFETY SYSTEMS, ETC.
13. THE CONTRACTOR SHALL PATCH, REPAIR AND INCORPORATE MATERIALS AND LABOR
NECESSARY TO COMPLETE AND FINISH ALL NEW AND REMODELED AREAS TO MATCH FIT,
FINISH AND QUALITY CONSISTENT WITH THE EXISTING BUILDING. MATERIALS AND PRODUCTS
SHALL BE FINISHED AND INSTALLED, I.E.; SEAMED, JOINTED AND PAINTED IN A UNIFORM
MANNER CONSISTENT IN MATCHING EXISTING ADJACENT PATTERNS, TEXTURES AND COLORS.
14. EXIT DOORS SERVING 50 OR MORE OCCUPANTS SHALL OPEN IN THE DIRECTION OF EXIT.
(CHAPTER 10 CBC)
15. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, SPECIAL
KNOWLEDGE OR EFFORT. (CHAPTER 11B CBC 2019). NOTE ALSO THAT FLUSH BOLTS OR
SURFACE BOLTS ARE PROHIBITED.
16. THE EXIT DOOR MUST OPEN OVER A LANDING NOT MORE THAN 1/2" BELOW THE THRESHOLD.
(CHAPTER 10 CBC)
17. DOORS WHEN FULLY OPENED AND HANDRAILS SHALL NOT REDUCE THE REQUIRED WIDTH OF
REQUIRED CORRIDORS BY MORE THAN 7 INCHES. DOORS IN ANY POSITION SHALL NOT
REDUCE THE REQUIRED WIDTH BY MORE THAN ONE HALF (CHAPTER 10 2019 CBC)
18. NO CHANGES SHALL BE MADE TO THE WORK NOTED ON THESE DRAWINGS WITHOUT THE
WRITTEN KNOWLEDGE AND CONSENT OF THE OWNER AND ARCHITECT. THE CONTRACTOR
SHALL NOTIFY THIS OFFICE OF ANY CONDITIONS FOUND THAT, IN THEIR OPINION, WOULD BE
DESIRABLE TO MODIFY OR CHANGE TO PRODUCE THE BEST RESULTS.
19. DIMENSIONS AS INDICATED ARE THE DIMENSIONS TO BE USED FOR CONSTRUCTION; DO NOT
SCALE THE DRAWINGS. IF A DIMENSION IS IN DOUBT, REQUEST CLARIFICATION FROM THE
ARCHITECT BEFORE PROCEEDING WITH THAT WORK. DIMENSIONS ARE TO FACE OF STUD
UNLESS NOTED OTHERWISE.
20. EXIT ILLUMINATION AND EXIT SIGN REQUIREMENTS SHALL COMPLY WITH 2019 CBC
21. THE MAXIMUM FORCE REQUIRED TO PUSH OR PULL A DOOR OPEN SHALL COMPLY WITH 2019
CBC 11B-404.2.0. OTHER THAN REQUIRED FIRE DOORS, INTERIOR DOORS SHALL HAVE A
MAXIMUM FORCE OF 5 LB/F. FIRE RATED DOORS SHALL NOT EXCEED 15 LB/F.
22. THE PROJECT IS SUBJECT TO THE NOISE STANDARDS ESTABLISHED IN THE CITY'S NOISE
ORDINANCE. PROJECT CONSTRUCTION IS EXEMPT ONLY DURING THE HOURS ALLOWED IN THE
CITY'S NOISE ORDINANCE. HOWEVER, ALL CONSTRUCTION EQUIPMENT SHALL BE MAINTAINED
AND IN GOOD WORKING ORDER, FITTED WITH FACTORY INSTALLED MUFFLING DEVICES.
B. ENTRANCES
1. ALL ACCESSIBLE ENTRANCES SHALL BE IDENTIFIED WITH AT LEAST ONE STANDARD SIGN AND
WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE FROM APPROACHING
PEDESTRIAN WAYS.
2. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE OF A SIZE AS TO PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 3 FEET IN WIDTH AND NOT LESS THAN 6 FEET, 8- INCHES IN HEIGHT. DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL
BE SO MOUNTED THAT THE CLEAR WIDTH OF THE DOORWAY IS NOT LESS THAN 32-INCHES.
3. WHERE A PAIR OF DOORS IS UTILIZED AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR
UNOBSTRUCTED OPENING WIDTH OF 32-INCHES WITH THE LEAF POSITIONED AT AN ANGLE OF
90 DEGREES FROM ITS CLOSED POSITION.
4. WHEN AN AUTOMATIC DOOR OPERATOR IS UTILIZED TO OPERATE A PAIR OF DOORS, AT LEAST
ONE OF THE DOORS SHALL PROVIDE A CLEAR UNOBSTRUCTED OPENING WIDTH OF 32-INCHES
WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.
5. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF
TRAVEL, SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE
WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE.
6. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30- INCHES AND
44-INCHES ABOVE THE FLOOR.
7. THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE LEVEL
AND CLEAR. THE LEVEL AND CLEAR AREA SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR
SWING OF AT LEAST 60-INCHES AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING
OF 48-INCHES AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED
POSITION.
8. THE WIDTH OF THE LEVEL AND CLEAR AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL
EXTEND 24-INCHES PAST THE STRIKE EDGE OF THE DOOR FOR EXTERIOR DOORS AND 18-
INCHES PAST THE STRIKE EDGE FOR INTERIOR DOORS.
9. THE BOTTOM 10-INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A
SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR
FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERE NARROW FRAME
DOORS ARE USED, A 10-INCH HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE
OF THE DOOR, WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST
WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION.
10. A NARROW FRAME WITH A BEVELED TOP EDGE (30 DEGREES MAXIMUM BEVEL TO VERTICAL
PLANE) INSTALLED AT THE BOTTOM OF A GLASS DOOR (WITH NO SIDE FRAMES) MAY BE USED IN
LIEU OF PROVIDING THE REQUIRED 10-INCH UNINTERRUPTED SURFACE AT THE BOTTOM OF
THE DOOR.
11. THE SPACE BETWEEN THE CONSECUTIVE DOOR OPENINGS IN A VESTIBULE, SERVING OTHER THAN A REQUIRED EXIT STAIRWAY SHALL PROVIDE A MINIMUM OF 48-INCHES OF CLEAR SPACE
FROM ANY DOOR OPENING INTO EACH VESTIBULE WHEN THE DOOR IS POSITIONED AT AN
ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. DOORS IN A SERIES SHALL SWING EITHER
IN THE SAME DIRECTION OR AWAY FROM THE SPACE BETWEEN THE DOORS.
C. SANITARY FACILITIES
1. WHEN SANITARY FACILITIES ARE LOCATED ON ACCESSIBLE FLOORS OF A BUILDING, THEY
SHALL BE MADE ACCESSIBLE TO THE PHYSICALLY DISABLED.
2. WHERE SEPARATE FACILITIES ARE PROVIDED FOR NON-DISABLED PERSONS OF EACH SEX,
SEPARATE FACILITIES SHALL BE PROVIDED FOR DISABLED PERSONS OF EACH SEX ALSO.
WHERE UNISEX FACILITIES ARE PROVIDED FOR NON-DISABLED PERSON, SUCH UNISEX
FACILITIES MAY BE PROVIDED FOR THE DISABLED.
3. ALL DOORWAYS LEADING TO SANITARY FACILITIES SHALL HAVE 32-INCH CLEAR
UNOBSTRUCTED OPENINGS.
4. ON DOORWAYS LEADING TO MEN'S SANITARY FACILITIES, AN EQUILATERAL TRIANGLE 1/4 -
INCH THICK WITH EDGES 12-INCHES LONG AND A VERTEX POINTING UPWARD SHALL BE
PROVIDED AND ON DOORWAYS LEADING TO WOMEN'S SANITARY FACILITIES A CIRCLE 1/4 -
INCH THICK AND 12-INCHES IN DIAMETER SHALL BE PROVIDED. THESE GEOMETRIC SYMBOLS
SHALL BE CENTERED ON THE DOOR AT A HEIGHT OF 60-INCHES AND THEIR COLOR AND
CONTRAST SHALL BE DISTINCTLY DIFFERENT FROM THE COLOR AND CONTRAST OF THE
DOOR.
5. A CLEAR SPACE MEASURED FROM THE FLOOR TO A HEIGHT OF 27-INCHES ABOVE THE
FLOOR, WITHIN THE SANITARY FACILITY ROOM, OF SUFFICIENT SIZE TO INSCRIBE A CIRCLE
WITH A DIAMETER NOT LESS THAN 60-INCHES, OR A CLEAR SPACE NOT LESS THAN 56-
INCHES X 63- INCHES IN SIZE SHALL BE PROVIDED. DOORS OTHER THAN THE DOOR TO THE
DISABLED TOILET COMPARTMENT IN ANY POSITION MAY ENCROACH INTO THIS SPACE BY
NOT MORE THAN 12-INCHES.
6. THE CENTERLINE OF THE ACCESSIBLE WATER CLOSET SHALL BE 16" MIN AND 18" MAX FROM
THE SIDE WALL OR PARTITION. A MIN 60" WIDE AND 48" DEEP MANEUVERING SPACE SHALL
BE PROVIDED IN FRONT OF THE WATER CLOSET.
7. WATER CLOSET COMPARTMENTS SHALL BE EQUIPPED WITH A DOOR THAT HAS AN
AUTOMATIC CLOSING DEVICE AND SHALL HAVE A CLEAR UNOBSTRUCTED OPENING WIDTH
OF 32-INCHES WHEN LOCATED AT THE END AND 34-INCHES WHEN LOCATED AT THE SIDE
WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.
8. EXCEPT FOR DOOR OPENING WIDTHS AND DOOR SWINGS, A CLEAR UNOBSTRUCTED
ACCESS NOT LESS THAN 44-INCHES SHALL BE PROVIDED TO WATER CLOSET
COMPARTMENTS DESIGNED FOR USE BY THE DISABLED. THE SPACE IMMEDIATELY IN
FRONT OF A WATER CLOSET COMPARTMENT SHALL BE NOT LESS THAN 48-INCHES AS
MEASURED AT RIGHT ANGLES TO THE COMPARTMENT DOOR IN ITS CLOSED POSITION.
D. TOILET ROOM FIXTURES AND ACCESSORIES
1. THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE A MINIMUM OF 17-INCHES AND A
MAXIMUM OF 19-INCHES MEASURED TO THE TOP OF THE TOILET SEAT.
2. TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE
TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR THE FLUSH
VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS, NO MORE THAN
44-INCHES ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO
GREATER THAN 5 POUNDS.
3. WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE A CLEAR SPACE 30-INCHES WIDE
X 48 -INCHES LONG IN FRONT OF THE URINAL.
4. WHERE URINALS ARE PROVIDED, AT LEAST ONE WITH A RIM PROJECTING A MINIMUM OF 14-
INCHES FROM THE WALL AND AT A MAXIMUM OF 17-INCHES ABOVE THE FLOOR SHALL BE
PROVIDED.
5. A CLEAR FLOOR SPACE 30-INCHES WIDE X 48-INCHES LONG SHALL BE PROVIDED IN FRONT OF
A LAVATORY TO ALLOW A FORWARD APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN
OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND INTO KNEE AND TOE SPACE
UNDERNEATH THE LAVATORY.
6. LAVATORIES SHALL BE MOUNTED WITH A CLEARANCE OF AT LEAST 29-INCHES FROM THE
FLOOR TO THE BOTTOM OF THE APRON WITH KNEE CLEARANCE UNDER THE FRONT LIP
EXTENDING A MINIMUM OF 30-INCHES IN WIDTH WITH 3-INCHES MINIMUM DEPTH AT THE TOP.
TOE CLEARANCE SHALL BE THE SAME WIDTH AND SHALL BE A MINIMUM OF 9-INCHES HIGH
FROM THE FLOOR AND A MINIMUM OF 17-INCHES DEEP FROM THE FRONT OF THE LAVATORY.
7. A PROJECTION OF A LAVATORY BOWL INTO THE 8-INCH CLEAR SPACE, THEREBY REDUCING
THE CLEAR HEIGHT BELOW THE LAVATORY TO NO LESS THAN 27-INCHES AT 8-INCHES BACK
FROM THE APRON, MEETS THE REQUIREMENT FOR PROVIDING KNEE CLEARANCE.
8. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE
COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.
9. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND
AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE
FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS PER
FOOT. LEVER-OPERATED, PUSH-TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE
EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET
REMAINS OPEN FOR AT LEAST 10 SECONDS.
10. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE NOT
MORE THAN 40-INCHES FROM THE FLOOR.
11. LOCATE TOWEL, SANITARY NAPKIN, AND WASTE RECEPTACLES WITH ALL OPERABLE PARTS
NOT MORE THAN 40-INCHES FROM THE FLOOR.
12. LOCATE TOILET TISSUE DISPENSERS ON THE WALL OR PARTITION CLOSEST TO THE WATER
CLOSET 7" MIN AND 9" MAX IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLINE
OF THE DISPENSER, MOUNTED BELOW THE GRAB BAR WITH THE OUTLET OF THE DISPENSER
AT A MIN HEIGHT OF 19".
13. GRAB BARS, FASTENERS AND MOUNTING DEVICES SHALL BE DESIGNED FOR 250 LB. PER
LINEAR FOOT LOAD.
E. GRAB BARS
1. GRAB BARS SHALL BE LOCATED ON ONE SIDE AND THE BACK OF THE ACCESSIBLE
COMPARTMENT AND SHALL BE SECURELY ATTACHED 33-INCHES TO BAR CENTERLINE AND
PARALLEL TO THE FLOOR.
2. GRAB BARS AT THE SIDE SHALL BE AT LEAST 48-INCHES LONG WITH THE FRONT END
POSITIONED 24-INCHES IN FRONT OF THE WATER CLOSET STOOL, AND GRAB BARS AT THE
BACK SHALL BE NOT LESS THAN 42-INCHES LONG.
3. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE 1-1/4
INCHES TO 1-1/2 INCHES IN DIAMETER OR AS NOTED ON PLANS.
4. IF THE GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL
AND THE GRAB BARS SHALL BE 1-1/2 INCHES.
5. A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY
SHARP OR ABRASIVE ELEMENTS.
6. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
F. ADDITIONAL A.D.A. REQUIREMENTS
1. THE CENTER OF THE RECEPTACLE OUTLETS SHALL BE NO MORE THAN 48" MEASURED FROM
THE TOP OF THE RECEPTACLE OUTLET BOX NOR LESS THAN 15" MEASURED FROM THE
BOTTOM OF THE RECEPTACLE BOX TO THE LEVEL OF THE FLOOR OR PLATFORM
2. THE CENTER OF THE GRIP OF THE OPERATING HANDLE OF SWITCHES INTENDED TO BE USED
BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE
OUTLETS, APPLIANCES, OR COOLING, HEATING AND VENTILATING EQUIPMENT, SHALL BE NOT
LESS THAN 15" NOR MORE THEN 48" ABOVE THE FLOOR OR WORKING PLATFORM.
3. THE CENTER OF FIRE ALARM INITIATING DEVICES (BOXES) SHALL BE LOCATED 48- INCHES
ABOVE THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK.
4. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY
FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY DISABLED PERSONS AS
SET FORTH IN THESE BUILDING STANDARDS. THE SYMBOL SPECIFIED ABOVE SHALL CONSIST
OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO.
15090 IN FEDERAL STANDARD 595A.
5. EMERGENCY WARNING SYSTEMS ARE REQUIRED TO INCLUDE AN INTEGRATED MEANS OF
WARNING THE HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY
OF NOT MORE THAN 60 FLASHES PER MINUTE.
6. NOTE: AT LEAST 5%, AND A MINIMUM OF 36" OF EACH TABLE/ COUNTER WORK SURFACE
AND/OR TRANSACTION STATION IN EMPLOYEE WORK AREAS, OR WHERE TRANSACTIONS
OCCUR BETWEEN SALES AND EMPLOYEES AND CUSTOMERS SHALL HAVE A SURFACE WHICH
IS BETWEEN 28" AND 34" ABOVE FLOOR. (CHAPTER 11 CBC)
7. ALL COMMON-USE KITCHEN AND/OR BAR/SINK AREAS SHALL HAVE CONTROLS THAT SHALL
BE (1) OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE GRASPING, PINCHING, OR
TWISTING OF THE WRIST; (2) REQUIRE NO MORE THAN 5 LBS. FORCE TO ACTIVATE; AND (3) BE
LEVER-OPERATED,PUSH TYPE, ELECTRONICALLY CONTROLLED OR SIMILAR.
G. GENERAL FIRE DEPARTMENT NOTES
1. CONSTRUCTION MATERIAL AND VEHICLES SHALL NOT OBSTRUCT FIRE APPARATUS ROADS,
FIRE HYDRANTS OR THE BUILDING.
2. BARRICADES SHALL BE PROVIDED TO PROTECT ANY NATURAL GAS METER, FIRE HYDRANT,
FIRE DEPARTMENT CONTROL DEVICE, OR OTHER POSSIBLE PERTINENT EQUIPMENT OR
DEVICES THAT MAY BE SUBJECT TO VEHICULAR DAMAGE.
3. PROVIDE AND MAINTAIN A MINIMUM 3-FOOT CLEAR SPACE AROUND FIRE PROTECTION
EQUIPMENT.
4. THE ALARM/FIRE WARNING SYSTEM SHALL BE CERTIFIED BY UNDERWRITER'S LABORATORY
(UL), AND SHALL BE MAINTAINED IN ACCORDANCE WITH CITY STANDARDS. PROOF OF
CERTIFICATION SHALL BE PROVIDED PRIOR TO APPROVAL OF OCCUPANCY. ADDITIONAL
WARNING DEVICES SHALL BE PROVIDED WHERE REQUIRED TO ASSIST THE HEARING IMPAIRED.
ALL DIGITAL ALARM COMMUNICATION TRANSMITTERS SHALL REPORT DISTINCTIVE SIGNALS
FROM THE SITE FOR WATER FLOW (BY BUILDING), GENERAL FIRE ALARM, SUPERVISORY AND
SYSTEM TROUBLE CONDITIONS.
5. THE BURNING OF COMBUSTIBLE CONSTRUCTION MATERIALS AND TRASH IS PROHIBITED.
6. TEMPORARY HEATING DEVICES SHALL BE OF AN APPROVED TYPE, LOCATED AWAY FROM
COMBUSTIBLE MATERIALS AND ATTENDED AND MAINTAINED AT ALL TIMES. HEATING DEVICES
SHALL NOT BE OPERATED AFTER NORMAL WORKING HOURS WITHOUT BEING ATTENDED TO ON
AN HOURLY BASIS.
7. CUTTING AND WELDING OPERATIONS SHALL CONFORM TO THE HOT WORK PROVISIONS OF
ARTICLE 49 OF THE CALIFORNIA FIRE CODE OR THE CITY FIRE CODE. A FIRE WATCH SHALL BE
PROVIDED DURING HOT WORK ACTIVITIES AND SHALL CONTINUE FOR A MINIMUM OF 30
MINUTES AFTER THE CONCLUSION OF THE WORK.
8. FIRE SAFETY DURING CONSTRUCTION SHALL COMPLY WITH ARTICLE 87 OF THE CALIFORNIA
FIRE CODE AS AMENDED BY THE CITY OF SACRAMENTO.
9. PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED IN OCCUPANCIES AND LOCATIONS AS SET FORTH IN THE CALIFORNIA FIRE CODE AND TITLE 19 CCR DIVISION 1, CHAPTER 3 AND AS
REQUIRED BY THE CHIEF. PROVIDE A MINIMUM OF ONE (1) PORTABLE FIRE EXTINGUISHER
WITHIN EACH TENANT SPACE. THE MAXIMUM TRAVEL DISTANCE TO THE FIRE EXTINGUISHER
SHALL NOT EXCEED 75 FEET. THE MINIMUM RATING CLASSIFICATION FOR THE EXTINGUISHER
SHALL BE NOT LESS THAN 2A-10B:C. THE MAXIMUM TRAVEL DISTANCE FROM ANY POINT IN A
LIGHT HAZARD AREA OF CLASS A HAZARDS SHALL NOT BE MORE THAN 75 FEET FROM A CLASS
2A-10B:C ONE EXTINGUISHER SHALL BE PROVIDED FOR EACH 3000 SQUARE FEET. THE
MAXIMUM TRAVEL DISTANCE FROM ANY POINT IN AN ORDINARY HAZARD OF CLASS A HAZARDS
AREA SHALL NOT BE MORE THAN 75 FEET AND ONE EXTINGUISHER SHALL BE PROVIDED FOR
EACH 3000 SQUARE FEET. THE MAXIMUM TRAVEL DISTANCE TO CLASS B EXTINGUISHERS IS
EITHER 30 FEET OR 50 FEET DEPENDING UPON THE SIZE OF THE EXTINGUISHER AND THE
CLASSIFICATION OF THE HAZARD. REFER TO UFC STANDARD NO. 10-1 FOR COMPLETE
REQUIREMENTS. ALL PORTABLE FIRE EXTINGUISHERS SHALL HAVE A SERVICE TAG AFFIXED TO
THEM SHOWING THAT THE EXTINGUISHER HAS BEEN SERVICED BY A CALIFORNIA STATE
LICENSED FIRE EXTINGUISHER CONCERN. ALL FIRE EXTINGUISHERS SHALL BE ATTACHED TO A
BRACKET OR WITHIN AN APPROVED CABINET. MAXIMUM DISTANCE FROM THE FLOOR SHALL
NOT EXCEED 54 INCHES. SIGNAGE SHALL BE POSTED ABOVE THE EXTINGUISHER AND SHALL
READ "FIRE EXTINGUISHER."
10. A SEPARATE PLAN CHECK SUBMITTAL AND PERMIT IS REQUIRED FOR ANY CHANGES NEEDED
TO THE EXISTING FIRE ALARM SYSTEM DUE TO THE TENANT IMPROVEMENT CONSTRUCTION OR
EXISTING CONDITIONS THAT ARE OUT OF CURRENT CODE COMPLIANCE. PLANS, INCLUDING
SEQUENCE OF OPERATIONS MATRIX, ZONES OR ADDRESS DESCRIPTIONS, POINT-TO-POINT
RISER DIAGRAM, BATTERY & VOLTAGE DROP CALCULATIONS AND C.S.F.M. LISTING APPROVAL
INFORMATION SHEETS, ETC., MUST BE SUBMITTED TO THE PERMIT COUNTER AT CITY HALL FOR
PLAN CHECK APPROVAL AND FIRE PERMIT FROM THE FIRE DEPARTMENT PRIOR TO
INSTALLATION.
FIRE SAFETY NOTES
1. ALL CONCEALED SPACES IN COMBUSTIBLE CONSTRUCTION ARE TO BE PROTECTED BY
AUTOMATIC FIRE SPRINKLERS UNLESS SPECIFICALLY EXEMPTED BY THE 2013 EDITION OF
NFPA 13 SECTION 8.15.1. OMITTING THE SPRINKLERS FROM SOME CONCEALED SPACES AS
PERMITTED BY SECTION 5-13. MAY REQUIRE THAT THE DESIGN AREA BE INCREASED IN
ACCORDANCE WITH SECTION 7-2.3.1.3
2. FIRE BLOCKING IS TO BE INSTALLED AS REQUIRED BY CBC SECTION 717. EXCEPTION: FIRE
BLOCKING WILL NOT BE REQUIRED AT 10-FOOT INTERVALS VERTICALLY IN EXTERIOR
COLUMNS AND FURRED SPACES ON THE EXTERIOR SIDE OF WALLS PROVIDED ALL OF THE
FOLLOWING CONDITIONS ARE SATISFIED:
1. THE CONCEALED SPACE IS ON THE EXTERIOR OF THE BUILDING;
2. THE CONCEALED SPACE IS VERTICAL;
3. THE CONCEALED SPACE DOES NOT EXCEED 10 FEET HORIZONTALLY BETWEEN
FIRE BLOCKING;
4. THERE ARE NO POTENTIAL SOURCES OF IGNITION WITHIN THE CONCEALED
SPACE;
5. THE INTERIOR CAVITY OF A COLUMN OR FURRED SPACE IS PROTECTED BY A FIRE
SPRINKLER(S) INSTALLED IN ACCORDANCE WITH UBC STANDARD 9-1. (THE FIRE
SPRINKLER(S) IS AT THE TOP OF THE CONCEALED SPACE, NOT IN AN ATTIC
CONNECTED TO THE CONCEALED SPACE); AND
6. THE CONCEALED SPACE IS FIRE-BLOCKED TO SEPARATE IT FROM ALL
HORIZONTAL CONCEALED SPACES SUCH AS SOFFITS, FLOOR-CEILING
ASSEMBLIES AND ATTICS.
H. REQUIREMENTS BY THE FIRE DEPARTMENT
1. INTERIOR WALL AND CEILING FINISHES FOR ASSEMBLY AREAS SHALL NOT EXCEED A FLAME-
SPREAD CLASSIFICATION OF 200 (CLASS III).
2. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A:10BC
WITHIN (75) FOOT TRAVEL DISTANCE TO: ALL PORTIONS OF THE BUILDING ON EACH FLOOR
DURING CONSTRUCTION.
3. WHERE REQUIRED, ROOM OCCUPANCY CAPACITIES SHALL BE POSTED WITH SIGNS
COMPLYING WITH THE REQUIREMENTS OF 2019 CBC SECTION AND TITLE 19 DIV. 1, CH.1
ARTICLE 3, SECTION 3.30
4. EXIT LIGHTING AND SIGNS: (CHAPTER 10 CBC) MINIMUM 6" x 3/4" LETTERS ON CONTRASTING
BACKGROUND.
5. EMERGENCY LIGHTING SHALL BE PROVIDED GIVING A VALUE OF ONE FOOT CANDLE AT
FLOOR LEVEL: (CHAPTER 10 CBC).
6. ONLY FIRE EXIT HARDWARE APPROVED BY THE STATE FIRE MARSHAL SHALL BE INSTALLED.
7. PROVIDE PORTABLE FIRE EXTINGUISHER WITH A RATING NOT LESS THAN 4A60 BC FOR
ELECTRICAL ROOM, AND MECHANICAL ROOM.
8. ROOF OBSTRUCTION SUCH AS TELEVISION ANTENNA, GUY WIRES, SOLAR PANELS, AND
RIBBON SHALL NOT PREVENT FIRE DEPARTMENT ACCESS OR EGRESS. FIRE DEPARTMENT
ACCESS TO ROOFS IN THE EVENT OF A FIRE SHALL NOT BE OBSTRUCTED BY WIRES,
RAZOR RIBBON, FENCES, CABLES, AERIALS, ANTENNAS, OR SOLAR PANELS.
9. EXIT SIGNS SHALL BE ELECTRICALLY ILLUMINATED AND THE TWO LAMPS SHALL BE
ENERGIZED FROM SEPARATE CIRCUITS. ILLUMINATION SHALL NORMALLY BE PROVIDED
BY THE PREMISES WIRING SYSTEM. IN THE EVENT OF FAILURE OF THIS SYSTEM,
ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED FROM AN EMERGENCY SYSTEM.
EMERGENCY LIGHTING SHALL GIVE A VALUE OF ONE FOOT CANDLE AT FLOOR LEVEL. (TITLE
24, C.C.R.).
10. EXIT PATH LIGHTING SHALL BE PROVIDED FOR STAIRWAY, HALLWAY, EXIT PASSAGEWAY AND
EGRESS TO A PUBLIC WAY ANY TIME THE BUILDING IS OCCUPIED.
11. PROVIDE TACTILE EXIT SIGNS WHERE REQUIRED (CHAPTER 10 CBC)
12. FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS TO MEET
REQUIREMENTS OF 2019 CBC SECTION 703.7.
G. DRINKING FOUNTAINS
1. WHERE WATER FOUNTAINS ARE PROVIDED OUTSIDE THE AREA OF REMODEL, THEY SHALL
COMPLY WITH DISABLED ACCESS REQUIREMENTS.
2. WATER FOUNTAINS SHALL BE LOCATED COMPLETELY WITHIN ALCOVES OR OTHERWISE
POSITIONED SO AS NOT TO ENCROACH INTO PEDESTRIAN WAYS. THE ALCOVE IN WHICH THE
WATER FOUNTAIN IS LOCATED SHALL BE NOT LESS THAN 32-INCHES IN WIDTH AND 18-
INCHES IN DEPTH.
3. THE DRINKING FOUNTAIN SHALL BE A MINIMUM OF 18-INCHES IN DEPTH AND THERE SHALL BE
CLEAR AND UNOBSTRUCTED KNEE SPACE UNDER THE DRINKING FOUNTAIN NOT LESS THAN
27-INCHES IN HEIGHT AND 8-INCHES IN DEPTH, THE DEPTH MEASUREMENT BEING TAKEN
FROM THE FRONT EDGE OF THE FOUNTAIN. ADDITIONALLY THERE SHALL BE TOE
CLEARANCE OF 9-INCHES IN HEIGHT ABOVE THE FLOOR, AND 17-INCHES IN DEPTH FROM THE
FRONT EDGE OF THE FOUNTAIN. A SIDE APPROACH DRINKING FOUNTAIN IS NOT
ACCEPTABLE.
4. THE BUBBLER SHALL BE ACTIVATED BY A CONTROL WHICH IS EASILY OPERATED BY A
DISABLED PERSON SUCH AS A HAND-OPERATED LEVER TYPE CONTROL LOCATED WITHIN 6-
INCHES OF THE FRONT OF THE DRINKING FOUNTAIN ETC. THE BUBBLER OUTLET ORIFICE
SHALL BE LOCATED WITHIN 6-INCHES OF THE FRONT OF THE DRINKING FOUNTAIN AND SHALL
BE WITHIN 36-INCHES OF THE FLOOR. THE WATER STREAM FROM THE BUBBLER SHALL BE
SUBSTANTIALLY PARALLEL TO THE FRONT EDGE OF THE DRINKING FOUNTAIN.
C27266
L
IC
ENSED A
T
RCHITEC
R 5EN. 0 -30- 2
S
AT
A
T E
OF C A L I FO
R N
I
Y E
VADJ.LEAH
CI
INTERIOR - ACCESSORIES - MOUNTING HEIGHTS & LOCATIONS
0500_0100_ACC MOUNTING HEIGHT ACCESSORIES_01
171108
M A
X
ACC LAV
(ACC SINK SIM.)
NOTE:
1. AT ACCESSIBLE TOILET STALLS, OPENING FOR PARTITION DOOR SHALL BE MIN. 34" CLEAR, DOOR SHALL BE SELF CLOSING, AND AN ACCESSIBLE DOOR
PULL SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH.
2. PROVIDE BACKING FOR ALL WALL HUNG ACCESSORIES, SEE TYPICAL BACKING DETAIL
3. BACKING LOCATIONS SHALL BE COORDINATED W/ ANCHORAGE LOCATIONS, TYP.
4. SEE INTERIOR ELEVATIONS FOR DEFINITIONS OF ACCESSORY ABBREVIATIONS.
5. WHERE WALL MOUNTED EQUIPMENT IS LOCATED ABOVE COUNTER/WORK SURFACE, HEIGHT TO OPERABLE PART SHALL BE 46" MAX. FOR PARALLEL
APPROACH.
6. WHERE WALL MOUNTED EQUIPMENT IS LOCATED ABOVE COUNTER/WORK SURFACE, HEIGHT TO OPERABLE PART FOR FORWARD APPROACH IS 48" MAX.
WHEN COUNTER/WORK SURFACE IS A MAXIMUM OF 20" DEEP. WHEN REACH DEPTH IS BETWEEN 20" AND THE MAXIMUM ALLOWABLE OF 25", THE HEIGHT
TO OPERABLE PARTS SHALL BE 44" MAX.
7. CONTRACTOR IS RESPONSIBLE FOR COORDINATING THAT MAXIMUM DIMENSIONS ARE NOT TO BE EXCEEDED AND MINIMUM CLEARANCES ARE NOT LESS
THAN THE MINIMUM DIMENSIONS LISTED.
18" MIN
SD
PTD
R E
F L
S
U R
F A
C E
M
A X
T O
MI-S
M A
X
M A
X
ACC UR
(ACCESSIBLE
URINAL)
13.5" MIN
UR
(URINAL)
M A
X
SR
(SHOWER
ROD)
MR & SSK
(MOP RACK & MOP SINK)
M A
X
SHOWER
CONTROL
VALVE
SST
(SHOWER
SEAT)
M
IN
M A
X
O T
H E
R S
CH
(COAT HOOK)
A C
C E
S S
IB
L E
MOP
RACK
SD
(SOAP
DISPENSER)
PTD
(PAPER
TOWEL
DISPENSER)
PTD/WR
(PAPER TOWEL
DISPENSER /
WASTE
RECEPTACLE)
MI-S / MI
(MIRROR STAINLESS
/ MIRROR)
HAND
DRYER
O U
T L
E T
M
IN
T
O
TPH
(TOILET
PAPER
HOLDER)
TSCD
(TOILET SEAT
COVER
DISPENSER)
A
F F
ALL OPERATING MECHANISMS SHALL BE NO
HIGHER THAN 3'-4" ABOVE FINISHED FLOOR AT
ACCESSIBLE TOILET ROOMS
C A
B
IN
E T
A N
D F
.E H
A N
D L
E
M
A X
T O
A L L
O P
E R
A B
L E
P A
R T
S O
F
FEC
(FIRE
EXTINGUISHER
CABINET)
INSULATE
ALL SUPPLY
AND DRAIN
PIPES, TYP
M
IN
8" MIN
ACC LAV
ELEVATION
M
IN
M
IN
ACC SINK
ELEVATION
8" MIN
M
IN
11" MIN
INSULATE
EXPOSED
SUPPLY AND
DRAIN PIPES
WHERE
OCCURS
11" MIN M
IN
MIN
24"
MIN
12"
M
IN
M
A X
5'-0" MIN CLR
T O
P O
F G
B
T O
V A
L V
E B
U T
T O
N
M A
X
GB42
FIN. FACE
OF WALL
24" MIN
4'-0" MIN
7"-9"
STPH OR
TPH
GB48
WC
PTN
(WATER CLOSET
PARTITION)
54" MIN
18" MAX
17" MIN
FACE OF
WALL OR
EDGE OF
LAV
12" MAX
FIN. FACE OF WALL
WHERE OCCURS
T O
P O
F G
B
T O
ACC WC
(ACCESSIBLE
WATER CLOSET)
ACC WC
(ACCESSIBLE
WATER CLOSET)
SANITARY
NAPKIN
DISPOSAL,
ADJACENT
TO TPH - 19"
AFF MAX TO
OPENING
T O
A L L
O P
E R
A B
L E
P A
R T
S
M A
X
HSD
(HAND
SANITIZER
DISPENSER)
FLEX SHOWER
SPRAY HOSE 59"
MIN LENGTH
ACCESSIBILITY CLEARANCES
0500_0100_ACC CLEARANCES_01
171108
T O
IL
E
T S
C
L R
(W A
L L
M T
D
5'-0" CLR
C L
R
A
3'-0"
O F
T A
B L E
F U
L L L
E N
G T
H
2'-6"
M
IN
TYPICAL TOILET
CLEARANCE
EXAM TABLE
CLEARANCE
30" X 48"
CLEAR FLOOR
WHEELCHAIR
SPACE
TYPICAL SINK
CLEARANCE
TYPICAL
LAVATORY
CLEARANCE
5'-0" CLEARANCE
CIRCLE
T-SHAPED
TURNING SPACE
REFRIGERATOR /
FREEZER PARALLEL
APPROACH
TYP STORAGE LOCKERS
(FORWARD APPROACH
SHOWN)
PROVIDE CLEARANCE AT BOTH
SIDES OF TABLE IN
EXAMINATION, DIAGNOSTIC
AND TREATMENT ROOMS.
GENERAL NON-EMERGENCY
EXAM ROOMS PROVIDE
CLEARANCE ON ONE SIDE PER
CBC 11B-805.4.1
2'-6" 2'-6"
M
IN
M A
X ø 5'-0
60" MIN
M
IN
M
IN
M
IN
NOTE:
FOR REQUIRED KNEE / TOE
CLEARANCES @
ACCESSIBLE SINK /
LAVATORY LOCATIONS,
SEE
4'-0"
24" MAX
REF
FRZ
NOTE:
'A' DESIGNATES ACCESSIBLE LOCKER.
THIS LOCKER SHALL HAVE OPERABLE
PARTS THAT ARE EASY TO GRASP WITH
ONE HAND THAT DO NOT REQUIRE
TIGHT GRASPING, PINCHING, OR
TWISTING OF THE WRIST TO OPERATE.
ALL OPERABLE PARTS, INTERIOR
HOOKS, AND SHELVES SHALL BE 48"
MAX. AFF. THERE MUST ALSO BE A
SHELF NO LOWER THAN 15" AFF. PER
CBC 11B-308 AND CBC 11B-309.4
FIXED
ACCESSIBLE
BENCH
2'-6"
48" MIN
D E
E P
M
IN
D E
E P
M A
X F
R O
M W
A L L
/2
M A
X
2 1/2" MAX
M
A X
M
IN
M
IN
M A
X
ACCESSIBLE
BENCH
ELEVATION (NTS)
MIN
12" 36" MIN
MIN
12"
2'-6"
GA522
GRAB BAR MOUNTING
0500_0100_GRAB BAR MOUNTING_01
1 1/2" SST TUBING
GRAB BAR
WALL, SEE PLAN
FOR TYPE
ESCUTCHEON PLATE
WOOD STUD
(3) #12 PAN HEAD WOOD
SCREWS W/ 1 1/2" MIN
EMBED INTO TYPE C
BACKING
FOR MOUNTING HEIGHTS SEE
1 1/2"
M
IN
M
IN
/2
PROJECTION FROM WALL
PROJECTION FROM
WALL, SEE
GA521
GA541
APPROVAL OF THIS PLAN DOES NOT
AUTHORIZE OR APPROVE ANY OMISSION OR
DEVIATION FROM APPLICABLE REGULATIONS.
FINAL APPROVAL IS SUBJECT TO FIELD
INSPECTION. ONE SET OF APPROVED PLANS
SHALL BE AVAILABLE ON THE PROJECT SITE
AT ALL TIMES.
OFFICE OF THE STATE FIRE MARSHAL
APPROVED FIRE AND PANIC ONLY
REVIEWED BY:
DATE:
1 2 3 4 5
D
C
B
A
SHEET
TITLE
MANAGEMENT
ISSUED
PROJECT
SEAL
CLIENT PROJECT NO:
LIONAKIS PROJECT NO:
IF
T
H
IS
S H
E E
T
IS
N O
T
0" x4
2" , I
E
D U
C E
D P
R
IN
T
S C
A
LE
A C
C O
R D
IN
REAL ESTATE SERVICE DIVISION
PROJECT MANAGEMENT &
DEVELOPMENT BRANCH
AGENCY
DGS PROJECT # DGS000000004638
CONSULTANT
ARCHITECT
/1
2/
:3 2:
A
M A ut od es k
D oc s:
//2
.0
W as hi ng to n
S tr ee t T
I/2
.0
1_ A
R C
H M
S T
E R
_A _R
_C
E N
T R
A L.
rv t
GA521
DETAILS - INTERIOR -
ACCESSIBILITY
21077.01
?00.00.00?
TENANT IMPROVEMENT
60 NORTH WASHINGTON STREET
SONORA, CA 95370
2 SOUTH GREENE ST., SONORA, CA
ISSUED FOR PERMIT SET - 100% CD
SEPTEMBER 8, 2023
1/4" = 1'-0"10
1/4" = 1'-0"20
2025 Nineteenth Street Sacramento CA 95818 P 916.558.1900 F 916.558.1919 www.lionakis.com
3" = 1'-0"16
C18997
L
IC
ENSED A
T
RCHITEC
R 3EN. 0 -28- 2
S
AT
A
T E
OF C A L I FO
R N
I
UOCOD
OH
SCI
N
LAS
ASI-001 MM/DD/YYYY ASI DESCRIPTION
HI-LO DRINKING FOUNTAIN -
WING WALLS
0500_0100_DF WING WALLS_01
A L C
O V
E
P T
H S
P
L A
N S
WING WALL AS
OCCURS SEE
FLOOR PLANS
CENTER OF BUBBLER
OUTLET & CONTROLS
6" FROM FRONT OF DF
ACCESSIBLE DRINKING
FOUNTAIN 18" MIN, 19"
MAX DEPTH
M
IN
O F
B U
B B
L E
R
M
A X
T O
C T
R
MIN
16"
CLMIN
16"
CL
OF DF
DEPTH
M
A X
TYPICAL ELEVATION TYPICAL SIDE ELEVATION
AT WING WALL
WING WALL,
SEE PLANS
FOR
LOCATIONS
TYPICAL PLAN
CLEAR
FLOOR
SPACE
30x48
CENTERED
ON LOW DF
VARIES, SEE PLAN
MIN
8"
MAX
6"
M
IN9
DEPTH
17" MIN
M
IN
WING WALLS,
SEE PLANS
D E
P T
H O
F
F
O R
Q1
ACCESSIBLE URINAL REQUIREMENTS
0500_0100_TYP URINAL ACCESS REQ_01
?YYMMDD?.
M A
X
M A
X
RIM PROJECTION
13 1/2" MIN
M A
X
M A
X
36" CLR
30" CLR 48" CLR
15" MIN
X<24"
C
L R
X
C
L R
48" CLR
X
X>24"
48" CLR
CL
30" X 48" MIN CLR REQUIREMENTS 36" X 48" MIN CLR REQUIREMENTS REQUIRED SINK CLEAR SPACE
AT WALL MOUNTED OBJECTS
0500_0100_REQ SINK CLEAR SPACE AT WALL MOUNTED OBJECTS_01
M
IN
1'-4"
BASED ON 9" TOE
SPACE HEIGHT
AND 1:6 KNEE
SPACE SLOPE
/2
M
IN
PER 11B-306.2.2
25" MAX
6" MAX
TOE SPACE
DEPTH PER
11B-306.2.4
SOAP, TOWEL, SWITCH, OUTLET, OR OTHER
OPERABLE PART ON WALL. 44" MAX. HEIGHT
PER 11B-308.2.2
NOTE: NOTHING CAN BE MOUNTED ON
THE BACK WALL UNLESS THE PROVIDED
TOE SPACE ALSO EXTENDS TO THE BACK
WALL PER 11B-308.2.2
NO PIPES, PLUMBING
FITTINGS, OR OTHER
INTRUSIONS
ALLOWED PAST
DASHED LINE
1'-7"
REMAINDER MUST BE KNEE
SPACE PER 11B-306.3
CLEARANCE AT LAVATORY
COUNTER
0500_0100_CLEARANCE AT DEEP LAVATORY_01
T O
E S
P A
C E
M
IN
C
L R
CLR TOE SPACE
6" MAX
MAX
3"
(SEE NOTE)
8"-10"
KNEE SPACE
1" 5
(SEE NOTE)
17"-19"
PLANE OF WALL
SOLID SURFACE
COUNTER AND
BACKSPLASH
O R
L A
V R
IM
T O
C O
U N
T E
R T
O P
M
A X
M
IN
M
IN
NOTE:
KNEE SPACE
CORRESPONDS W/
LAVATORY
COUNTER DEPTH.
IF LAV IS 17" DEEP,
THEN KNEE SPACE
MUST BE AT LEAST
8" ETC.
REACH OVER OBSTRUCTION
0500_0100_REACH OVER_01
?YYMMDD?
6"VARIES
(SEE NOTE)
19" MIN TOE SPACE DEPTH
(SEE NOTE)
25" MAX REACH DEPTH
FINISH FACE OF
WALL WITH
ELECTRICAL
RECEPTACLES OR
SWITCH
ALLOWABLE KNEE
SPACE
REDUCTION AT
PLUMBING
FIXTURES SEE
NOTE:
TOE SPACE MUST
BE EQUAL TO, OR
GREATER THAN
REACH DEPTH
M
IN
A T
L A
V A
T O
R
IE
S
M
IN
A
T W
O R
K C
O U
N T
E R
S A
N D
S
IN
K S
M
IN
GA522
GA522
MIN LAVATORY KNEE/TOE
CLEARANCE
0500_0100_MIN LAVATORY KNEE/TOE CLEARANCE_01
(SEE NOTE)
8"-10"
KNEE SPACE
(SEE NOTE)
17"-19"
M
IN
A T
F R
O N
T A
P R
O N
M
IN 3
M A
X
TOE SPACE
6" MAX CLR
3" MAX
T O
E S
P A
C E
M
IN
C
L R
NOTE:
KNEE SPACE CORRESPONDS
W/LAVATORY FIXTURE
DEPTH. IF LAV IS 17" DEEP,
THEN KNEE SPACE MUST BE
AT LEAST 8" ETC.
ACCESSIBLE STALL
REQUIREMENTS
0500_0100_ACC STALL REQ_01
A
B
B
B
AT END OPENING, IN SWINGING DOOR
60" MIN @ SIDE OPENING DOOR OR
48" MIN @ END OPENING, OUT SWING DOOR
A
B
M
IN
M
IN
MOUNTED WC
59" MIN AT FLOOR
MOUNTED WC
56" MIN AT WALL
M
IN
M A
X
4" MAX
NOTES:
1. PROVIDE A TOE CLEARANCE OF 9 INCHES MINIMUM
ABOVE THE FINISH FLOOR.
2. COMPARTMENTS FOR CHILDREN'S USE SHALL
PROVIDE A TOE CLEARANCE OF 12 INCHES MINIMUM
ABOVE THE FINISHED FLOOR.
3. WHERE PARTITION TOE CLEARANCES ARE LESS THAN
THE ABOVE DIMENSIONS 66" CLEAR STALL IS REQUIRED.
NOTE:
PROVIDE SELF CLOSING
HINGES, LATCH AND DOOR
PULLS ON BOTH SIDES OF
THE DOOR NEAR THE LATCH.
34" MIN
M
IN
M
IN
C
L R
17" MIN
18" MAX 18" MIN
60" MIN CLR SPACE
WC
LAV.FLUSH VALVE
ON WIDE SIDE
48" GRAB BAR
60" MIN DIA CLR
12" M
AX
S E
E F
L O
O R
P L
A N
SEE FLOOR PLAN
M
IN
30"x48" CLR
SPACE
ACCESSIBLE TOILET ROOM
CLEARANCES - SINGLE
ACCOMMODATION
0500_0100_ACC RR CLEARANCES SINGLE_01
FOF
REQD DOOR
CLEARANCE
, SEE DETAIL
F O
F
L O
N G
E S
T W
C
A S
S U
M E
D
CL
42" GRAB BAR
CL
GA541
M
IN
C
L R
60" CLR
42" MIN
12"
MAX
54" MIN
GRAB BAR
NO PROJECTIONS
WITHIN 12" ABOVE
GRAB BAR OR WITHIN
1 1/2" BELOW OR AT
ENDS OF GRAB BAR
TPD
FINISH FLOOR
CL
7"-9" FROM
FRONT OF
TOILET
19" MIN TO
DISPENSING
POINT
M A
X
M
IN
ACCESSIBLE WATER CLOSET
REQUIREMENTS - SIDE
0500_0100_ACC WATER CLOSET REQ SIDE_01
TOILET SEAT
COVERS
SANITARY NAPKIN
DISPOSAL
T O
P O
F O
P E
N
IN
G
T O
O P
E N
IN
G
A F
F M
A X
42" MIN
12" MIN 24" MIN
17" MIN
18" MAX
M A
X
M
IN
FINISH FLOOR
NO PROJECTIONS
WITHIN 12" ABOVE
GRAB BAR OR 1 1/2"
BELOW OR AT ENDS
OF GRAB BAR
36" MIN REAR
GRAB BAR
ACCESSIBLE WATER CLOSET
REQUIREMENTS - FRONT
0500_0100_ACC WATER CLOSET REQ FRONT_01
APPROVAL OF THIS PLAN DOES NOT
AUTHORIZE OR APPROVE ANY OMISSION OR
DEVIATION FROM APPLICABLE REGULATIONS.
FINAL APPROVAL IS SUBJECT TO FIELD
INSPECTION. ONE SET OF APPROVED PLANS
SHALL BE AVAILABLE ON THE PROJECT SITE
AT ALL TIMES.
OFFICE OF THE STATE FIRE MARSHAL
APPROVED FIRE AND PANIC ONLY
REVIEWED BY:
DATE:
1 2 3 4 5
D
C
B
A
SHEET
TITLE
MANAGEMENT
ISSUED
PROJECT
SEAL
CLIENT PROJECT NO:
LIONAKIS PROJECT NO:
IF
T
H
IS
S H
E E
T
IS
N O
T
0" x4
2" , I
E
D U
C E
D P
R
IN
T
S C
A
LE
A C
C O
R D
IN
PROJECT MANAGEMENT &
DEVELOPMENT BRANCH
AGENCY
DGS PROJECT # DGS000000004638
CONSULTANT
ARCHITECT
/1
2/
:3 2:
A
M A ut od es k
D oc s:
//2
.0
W as hi ng to n
S tr ee t T
I/2
.0
1_ A
R C
H M
S T
E R
_A _R
_C
E N
T R
A L.
rv t
GA522
DETAILS - INTERIOR -
ACCESSIBILITY
21077.01
?00.00.00?
TENANT IMPROVEMENT
60 NORTH WASHINGTON STREET
SONORA, CA 95370
2 SOUTH GREENE ST., SONORA, CA
ISSUED FOR PERMIT SET - 100% CD
SEPTEMBER 8, 2023
3/8" = 1'-0"3
1/2" = 1'-0"8 1" = 1'-0"16
1 1/2" = 1'-0"14
1 1/2" = 1'-0"15
1 1/2" = 1'-0"133/8" = 1'-0"9
3/8" = 1'-0"12
1/2" = 1'-0"11
1/2" = 1'-0"10
2025 Nineteenth Street Sacramento CA 95818 P 916.558.1900 F 916.558.1919 www.lionakis.com
C18997
L
IC
ENSED A
T
RCHITEC
R 3EN. 0 -28- 2
S
AT
A
T E
OF C A L I FO
R N
I
UOCOD
OH
SCI
N
LAS
'X
4" MAX IF 'X' > 27"
'P'
'X
PROVIDE CANE
DETECTABLE
ELEMENT
IF 'P' > 4" AND 'X' > 27"
PROTRUDING OBJECTS
0500_0100_PROTRUDING OBJECTS_01
?YYMMDD?
M
IN
PROTRUDING
OBJECT
PROTRUDING
OBJECT
FINISHED FLOOR
ACCESSIBLE HANDRAIL AT WALL
0500_0100_ACC HNDRL AT WALL_01
NOT TO SCALE
" 1'-0"
DEPTH
TREAD
4'-0" MAX
SPACING OF WALL
MTD BRACKETS
LANDING
FIN. LANDING
1'-0"
1 1/2" OD 13 GA TUBE
WALL MOUNTED BRACKET
ATTACHMENT VARIES
WALL CONSTRUCTION
INSIDE FACE OF
STAIR CORE WALL
PLAN
ELEVATION
/2
C L
R
WHERE WALL IS ROUGH
OR ABRASIVE (SUCH AS
CONCRETE OR
STUCCO) PROVIDE
METAL PROTECTION
PLATE
1'-0"
M
IN
M A
X
DOOR HANDLE/
PANIC HARDWARE
WHERE OCCURS
U N
O B
S T
R U
C T
E D
M A
X
M
IN
U
O N
SWITCHES
CONVENIENCE
WALL OUTLET
THERMOSTAT
FIRE ALARM
KICK PLATE
ACCESSIBLE MOUNTING HEIGHT
REQUIREMENTS
0500_0100_ACC MOUNTING HEIGHT REQ DOOR_01
?YYMMDD?
FINISHED
FLOOR
S M
O O
T H
U
N
IN
T E
R R
U P
T E
D S
U R
F A
C E
M
IN
F U
L L
W
ID
T H
O F
D O
O R
PUSH SIDE
ACCESSIBLE DOOR SURFACE
REQUIREMENT
0500_0100_ACC DOOR SURFACE REQ_01
DOOR OTHER THAN
SLIDING DOOR IN
ACCESSIBLE PATH OF
TRAVEL
/4
M
A X
/2
M
A X
/4
M
A X
CARPET WILL NOT EXCEED 1/2"
HIGH PILE WHERE INSTALLED
CARPET TO BE PERMANENTLY
AND SECURELY AFFIXED TO
FLOOR
MAXIMUM HEIGHTS AT ALL
THRESHOLDS
MAXIMUM HEIGHT AT SLOPED
LEVEL CHANGE
MAXIMUM HEIGHT AT LEVEL
CHANGE WITH NO
TRANSITION
/2
M
A X
FLOORING TRANSITION
0500_0100_FLOORING TRANSITIONS_01
MAX
MAX
/4
M
A X
/4
M
IN
M
IN
M
IN
P U
L L S
ID
E
P U
S H
S
ID
E
C L
X
T E
R
IO
O R
C L
IN
E R
IO
O
R
CLEAR SPACE FINISH
ELEVATION TO MATCH
FINISH FLOOR ELEVATION
AT DOOR
PROVIDE THIS ADDITIONAL
SPACE IF DOOR IS EQUIPPED
WITH A LATCH AND A CLOSER
C L E
A R
O P
E N
IN
G
M
IN
5'-0" 4'-0"
FRONT APPROACH DOOR CLEARANCES, TYP
44" MIN 60" MIN
M
IN
C L E
A R
O P
E N
IN
G
M
IN
M
IN
48" MIN IF DOOR HAS A
LATCH AND CLOSER
HINGE APPROACH DOOR CLEARANCES, TYP
PUSH SIDE
PULL SIDE
PULL SIDEPUSH SIDE
44" MIN 60" MIN
M
IN
C L E
A R
O P
E N
IN
G
M
IN
48" MIN IF DOOR HAS A
CLOSER
LATCH APPROACH DOOR CLEARANCES, TYP
NOTE: AREA MUST NOT EXCEED A SLOPE OF 2% IN ANY DIRECTION
ACCESSIBLE DOOR CLEARANCES
0500_0100_ACC DOOR CLEARANCES_01
WHERE AN OBSTRUCTION IS
MORE THAN 8", PROVIDE
THE NOTED CLEAR SPACE
M
IN
ACCESSIBLE DOOR HARDWARE
REQUIREMENTS
0500_0100_ACC DOOR HARDWARE REQ_01
HAND-ACTIVATED DOOR OPENING
HARDWARE, HANDLES, PULLS,
LATCHES. LOCKS AND OTHER
OPERATING DEVICES ON ACCESSIBLE
DOORS SHALL HAVE A SHAPE THAT IS
EASY TO GRASP WITH ONE HAND AND
DOES NOT REQUIRE TIGHT GRASPING.
TIGHT PINCHING OR TWISTING OF THE
WRIST TO OPERATE.
LATCHING AND LOCKING DOORS THAT
ARE HAND-ACTIVATED AND WHICH ARE
IN ACCESSIBLE ROUTE, SHALL BE
OPERABLE WITH A SINGLE EFFORT BY
LEVER-TYPE HARDWARE, PANIC BARS
OR OTHER HARDWARE DESIGNED TO
PROVIDE PASSAGE. LOCKED EXIT
DOORS SHALL OPERATE AS ABOVE IN
EGRESS DIRECTION.
LEVER
LOOP
PUSH
1.
2.
1. MINIMUM CLEAR FLOOR OR GROUND SPACE REQUIRED TO ACCOMMODATE A
SINGLE, STATIONARY WHEELCHAIR AND OCCUPANT IS 30 INCHES BY 48 INCHES.
MINIMUM CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS MAY BE
POSITIONED FOR FORWARD OR PARALLEL APPROACH TO AN OBJECT, UNLESS
RESTRICTED BY CODE. FLOOR OR GROUND SPACE FOR WHEELCHAIRS MAY BE
PART OF THE KNEE SPACE REQUIRED UNDER SOME ELEMENTS AS ALLOWED BY
CODE.
2. PROVIDE A MINIMUM CLEAR SPACE 60 INCHES WIDE AT ALCOVES GREATER THAN
15 INCHES DEEP AND DESIGNED FOR SIDE APPROACH.
3. PROVIDE A MINIMUM CLEAR SPACE 36 INCHES WIDE AT ALCOVES GREATER THAN
24 INCHES DEEP AND DESIGNED FOR FRONT APPROACH.
CLEAR FLOOR SPACE FOR WHEELCHAIRS
1. OBJECTS PROJECTING FROM WALLS WITH THEIR LEADING EDGES BETWEEN 27 INCHES AND 80 INCHES ABOVE THE FINISHED FLOOR SHALL PROTRUDE NO MORE THAN 4" INTO WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES.
2. OBJECTS MOUNTED WITH THEIR LEADING EDGES AT OR BELOW 27 INCHES ABOVE THE
FINISHED FLOOR MAY PROTRUDE ANY AMOUNT.
3. FREE-STANDING OBJECTS MOUNTED ON POSTS / PYLONS MAY OVERHANG 12 INCHES MAXIMUM
FROM 27 INCHES TO 80 INCHES ABOVE THE GROUND OR FINISHED FLOOR.
4. PROTRUDING OBJECTS SHALL NOT REDUCE THE REQUIRED CLEAR WIDTH OF AN ACCESSIBLE
ROUTE OR MANEUVERING SPACE.
5. ANY OBSTRUCTION OVERHANGING A PEDESTRIAN WAY SHALL BE A MINIMUM OF 80 INCHES
ABOVE THE WALKING SURFACE AS MEASURED TO THE BOTTOM OF THE OBSTRUCTION.
HAZARDOUS AND PROJECTING OBJECTS
1. SURFACE SLOPES OF ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL NOT EXCEED
1/4 INCH PER FOOT (2% GRADIENT) IN ANY DIRECTION.
2. ACCESSIBLE PARKING SPACES SHALL BE LOCATED SO AS NOT TO REQUIRE USERS TO TRAVEL
OR WALK BEHIND ANY PARKING SPACE OTHER THAN THEIR OWN.
3. IN EACH PARKING AREA, A BUMPER OR CURB SHALL BE PROVIDED AND LOCATED TO PREVENT
ENCROACHMENT OF CARS OVER THE REQUIRED WIDTH OF WALKWAYS.
4. PARKING SPACES RESERVED FOR PERSONS WITH DISABILITIES SHALL BE IDENTIFIED BY A
REFLECTORIZED SIGN PERMANENTLY POSTED IMMEDIATELY ADJACENT TO AND VISIBLE FROM
EACH STALL OR SPACE CONSISTING OF A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT,
IN WHITE ON DARK BLUE BACKGROUND. THE SIGN SHALL NOT BE SMALLER THAN 70 INCHES IN
AREA AND, WHEN IN AN ACCESSIBLE ROUTE, SHALL BE POSTED AT A MINIMUM HEIGHT OF 80
INCHES FROM THE BOTTOM OF THE SIGN TO THE PARKING SPACE FINISHED GRADE. SIGNS
MAY ALSO BE MOUNTED ON THE WALL AT THE INTERIOR END OF THE PARKING SPACE AT A
MINIMUM HEIGHT OF 60 INCHES FROM THE PARKING SPACE FINISHED GRADE, GROUND, OR
WALK.
PARKING
1. THE INFORMATION DEPICTED ON THIS SHEET REPRESENT BUILDING CODE
REQUIREMENTS. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES
ON THIS PROJECT THAT WOULD CREATE A CONFLICT WITH THE PLANS OR
ACCESS REQUIREMENTS.
DISCREPANCIES
ACCESSIBLE ROUTE NOTES
0500_0100_ACC ROUTE NOTES_01
?YYMMDD?
1. IN NEW CONSTRUCTION, ALL PRIMARY ENTRANCES AND EXTERIOR GROUND FLOOR EXIT
DOORS TO BUILDINGS AND FACILITIES SHALL BE ACCESSIBLE TO THE DISABLED.
2. IN EXISTING BUILDINGS WHERE NOT ALL ENTRANCES ARE ACCESSIBLE, ALL ACCESSIBLE
ENTRANCES SHALL BE IDENTIFIED WITH AT LEAST ONE STANDARD INTERNATIONAL SYMBOL
OF ACCESSIBILITY SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE
FROM APPROACHING PEDESTRIAN WAYS.
3. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE OF A SIZE AS TO PERMIT
THE INSTALLATION OF A DOOR NOT LESS THAN 36 INCHES IN WIDTH, AND NOT LESS THAN
80 INCHES IN HEIGHT. DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND
SHALL BE MOUNTED SO THAT THE CLEAR WIDTH THE DOORWAY IS NOT LESS THAN 32
INCHES.
4. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE PART OF AN
ACCESSIBLE ROUTE OR SPACE, SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER
TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS. OR OTHER HARDWARE
DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE
OPENING HARDWARE.
5. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 34 INCHES
MINIMUM AND 44 INCHES MAXIMUM ABOVE THE FLOOR.
6. THE FLOOR OR LANDING LENGTH ON EACH SIDE OF AN ENTRANCE OR A PASSAGE DOOR
SHALL BE LEVEL AND CLEAR AT LEAST 60 INCHES IN THE DIRECTION OF THE DOOR SWING
AND AT LEAST 48 INCHES OPPOSITE THE DIRECTION OF THE DOOR SWING AS MEASURED
AT RIGHT ANGLES TO THE FACE OF THE DOOR IN THE CLOSED POSITION. THE WIDTH OF
THE LEVEL AND CLEAR AREA ON THE SIDE WHICH THE DOOR SWINGS SHALL EXTEND A
MINIMUM OF 24 INCHES PAST THE STRIKE EDGE OF THE DOOR FOR DOORS WITH LATCH
SIDE APPROACH AND 36 INCHES FOR DOORS REQUIRING HINGE SIDE APPROACH.
7. THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2 INCH LOWER THAN THE
THRESHOLD OF THE DOORWAY. CHANGES IN LEVEL BETWEEN 1/4 INCH AND 1/2 INCH SHALL
BE BEVELED WITH A SLOPE NO GREATER THAN 1:2.
8. THE BOTTOM 10 INCHES OF ALL DOORS (EXCEPT AUTOMATIC AND SLIDING) SHALL HAVE A
SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A
WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION WHERE
NARROW…