Attachment F - Tc-99 30_Gallon Drums-RFB 20-128.pdf
PDF 220 KB Posted
- Attached to
- Radioactive Waste Disposal
- Solicitation number
- RFB 758 2000000128 1
- Issued by
- Elliott County, Kentucky
About this file
This is a technical specification document for Tc-99 30-gallon drums included in Request for Bid (RFB) 20-128. The document details nine drums containing radioactive materials, with eight drums containing primarily Tc-99 isotopes and one drum (Tc-99+Mix_I) containing a mixture of multiple radioactive isotopes including Tc-99, Sr-90, U-233, Cs-137, Am-241, natural uranium, Co-60, Pu-239, Ra-228, Ba-133, and Ra-226. The drums vary significantly in radioactive content, ranging from 1.1E+05 to 1.6E+07 disintegrations per minute (DPM) per drum, with vial counts between 48 and 1,800 vials per drum. The total DPM across all drums is 5.8E+07, with documented dose-on-contact background radiation and identified chemical contamination including toluene.
The document provides detailed radiological inventory data for procurement purposes but does not specify pricing terms, contract duration, set-asides, bid submission deadlines, site visit requirements, or other standard bidding parameters. This appears to be an attachment containing technical specifications for radioactive waste or materials that would be referenced in the complete RFB 20-128 solicitation document.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Tc-99 30-Gallon Drums
Rad Drum ID Tc-99 DPM/drum # of vials Tc-99_A 1.1E+05 600 vials Tc-99_B 1.6E+07 1800 vials Tc-99_C 7.0E+05 1591 vials Tc-99_D 1.2E+07 1400 vials Tc-99_E 2.4E+05 1130 vials Drums contain only Tc-99
Tc-99_F 2.5E+06 1400 vials Tc-99_G 1.1E+07 1200 vials
Tc-99+Sr-90_H 2.6E+06 1000 vials Drum contains Tc-99 and Sr-
Tc-99+Mix_I 1.3E+07 1400 vials
U-233 5.0E+02 1352 vials -Tc-
Cs-137 6.6E+04 48 vials -Other Am-241 5.0E+04 U(nat) 9.2E+03
Co-60 7.5E+02 All contained in Drum Tc- 99+Mix_I
Pu-239 4.5E+04 Sr-90 1.0E+03
Ra-228 3.6E+02 Ba-133 8.0E+03 Ra-226 3.0E+04 Tc-99 1.3E+07
Total DPM (all drums) 5.8E+07
Dose on contact background
Non-Rad Chemical Toluene (<1% by volume) 1M Nitric acid (7% by volume) 3M Nitric acid (<1% by volume) Ultima Gold AB Opti-fluor Insta-Gel pH (each vial) <2 Total volume (gallons) 48.7 Number of drums 9 (Glass & plastic vials inside drums)
File details come from the government source that posted it. Updated .