This is a technical submittal drawing for a FlexShade FM motorized dual roller outside-mount (overhead) shade system with small endcap and fascia configuration, prepared by Draper for order number MT0126. The drawing provides detailed specifications for the shade installation, including a parts list identifying the motor tube, spline roller, shade fabric, and hem pocket components. The documentation includes dimensional specifications in both inches and millimeters, such as a maximum bundle diameter of 2 3/4 inches [69.9mm] and shade height of 11 1/16 inches [42.1mm]. The drawing utilizes editable layers to allow project-specific customization and indicates that blocking and fasteners are to be provided by others per project requirements.

The technical specifications note that Draper recommends minimum 2x wood blocking (2-3/4" plywood or equivalent 2x material) or minimum 18 gauge flat sheet steel between framing and the finished ceiling for structural support. The drawing is designated as a standard detail template suitable for adaptation to various curtain wall and window sill applications, with provisions for vertical mullion configuration. Draper reserves the right to discontinue or modify products without notice, and all dimensions referenced in the documentation are subject to standard engineering tolerances and project-specific modifications as needed for installation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SH

EET:

O F:

O R

D

ER

N O

JOB NAME:

LOCATION:

DEALER:

MODEL:

SUBMITTAL DATE:

DRAWN:

REVISED:

REVISED:

AS BUILT:

M T0

6:

F

LE

XS

HA

DE

D

FM

O

S m al l D ua l R ol le r E nd ca p

F as ci a

R eg ul ar

R ol l / / O ut sid e M ou nt

(O ve rh ea d)

PARTS LIST

DESCRIPTIONITEM

1 Blocking By Others per Note 3 at Left 2 Fasteners By Others

Motor

Tube, Spline Roller Shade Fabric

GLASS CURTAIN WALL

CEILING

Hem Pocket

USER NOTE: WE HAVE USED DRAWING LAYERS TO MAKE THESE STANDARD DETAILS EASIER TO ADAPT TO YOUR PROJECT SPECIFIC DETAILS. YOU CAN TURN OFF/ON LAYERS WITHIN YOUR EDITING SOFTWARE.

WINDOW SILL

VERTICAL MULLION

NOTES: UNLESS OTHERWISE SPECIFIED.

1. DRAPER RESERVES THE RIGHT TO DISCONTINUE OR MODIFY ANY PRODUCT WITHOUT NOTICE

2. ALL DIMENSIONS ARE IN INCHES [mm].

3. BLOCKING BY OTHERS: DRAPER RECOMMENDS MIN 2X WOOD BLOCKING (2-3/4" [69.9] PLYWD OR 2X) OR MIN 18 GA FLAT SHEET STEEL OR SIM. IF WOOD, BLOCKING SHOULD BE BETWEEN FRAMING AND FINISHED CEILING.

16 [176.1mm]

SHADE HEIGHT

4 [120.1mm]

Ø23 4 [Ø69.9mm]MAX

BUNDLE DIAMETER

Ø23 4 [Ø69.9mm]MAX

BUNDLE DIAMETER

16 [42.1mm]