This is a vendor compliance worksheet template designed for the Viera VA facility's Reverse Osmosis (RO) water system replacement project. The worksheet requires vendors to document their proposed RO equipment specifications, including manufacturer and model information, system capacity, and relevant certifications or standards met. The compliance sheet is structured in sections addressing general requirements and system performance metrics, with vendors required to indicate whether their proposed equipment meets specified criteria such as RO semipermeable membrane technology utilization and 95-99% contaminant rejection rates.

This worksheet is part of a Sources Sought Notice (Solicitation Number 36C24826Q1094) issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8 for market research purposes only. The government seeks qualified contractors capable of providing complete labor, materials, equipment, and services necessary to remove and replace the RO water system supporting Sterile Processing Service operations at the Viera VA facility. Interested vendors must submit the completed compliance worksheet along with Attachment B by the response deadline of 10:00 AM on August 12, 2026, via email to rohan.mckenzie@va.gov with the subject line "Sources Sought Viera SPS RO System Replacement." The notice explicitly disclaims that responding does not guarantee inclusion in any future solicitation or obligate the government to issue a formal RFQ or RFP.

View the file

Other files

File Type Posted
ATTACHMENT B - VENDOR RESPONSE FORM.docx DOCX document
ATTACHMENT A - DRAFT STATEMENT OF WORK.pdf PDF
36C24826Q1094.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT C

Salient‑Characteristics Compliance Worksheet Requirement: Viera SPS Reverse Osmosis (RO) Water System Replacement Vendor Name: _______________________________ Proposed RO Equipment:

Manufacturer/Model ___________________________________________ System Capacity ______________________________________________ Certifications/Standards Met: ______________________________ Section 1 – General Requirements

Requirement
Meets? (Y/N)
Evidence Provided
System uses RO semi‑permeable membrane technology
Y/N
95–99% contaminant rejection
Y/N

Section 2 – System Performance

Requirement
Meets?
Evidence
TDS output <10–20 ppm
Y/N
Continuous‑duty rating
Y/N
Configurable recovery rate
Y/N

Section 3 – Feedwater / Operating Conditions

Requirement
Meets?
Evidence
Operates within required pressure & temperature range
Y/N
Tolerates feedwater pH, chlorine/chloramine
Y/N
Includes/compatible with pretreatment (sediment, carbon, softener)
Y/N

Section 4 – Mechanical / Electrical

Requirement
Meets?
Evidence
Integrated high‑pressure pump sized for load
Y/N
Corrosion‑resistant housing & plumbing
Y/N
Electrical compatibility (120/240V, etc.)
Y/N

Section 5 – Controls & Instrumentation

Requirement
Meets?
Evidence
Monitors pressure (feed/permeate/concentrate)
Y/N
Monitors permeate & concentrate flow
Y/N
Conductivity or resistivity monitoring
Y/N
Automatic flushing & safeguards
Y/N
Alarms (high TDS, low pressure, pump faults)
Y/N

Section 6 – Maintenance / Serviceability

Requirement
Meets?
Evidence
Modular design (prefilters, pumps, membranes)
Y/N
Supports membrane cleaning or replacement
Y/N
No special tools required
Y/N

Section 7 – Environmental / Installation

Requirement
Meets?
Evidence
Suitable for SPS feedwater
Y/N
Floor or wall mount acceptable
Y/N
Noise/heat within indoor operation limits
Y/N

Section 8 – Certifications & Compliance

Requirement
Meets?
Evidence
NSF/ANSI safety compliance
Y/N
UL/ETL electrical compliance
Y/N
Manufacturer documentation provided
Y/N

Compliance Summary for Internal Use Only

Category
Result

Total Salient Characteristics Met: ___ / ___

Compliant? (All Required Y/N):
Yes / No