Attachment C - Line 1.pdf

PDF 223 KB Posted

Attached to
D5 Mast Arm Pole
Solicitation number
RFB 605 2200000056 1
Issued by
Bath County, Kentucky

About this file

This is a structural design analysis document for an over-height detection system prepared by the Kentucky Transportation Cabinet, District 5, for Jefferson County in Louisville. The project involves the design and analysis of a 21.50-foot vertical pole (Pole A) with two mast arms extending 35 feet in length at a height of 19 feet, along with associated luminaire arms and custom attachments. The over-height detection equipment attachment measures 102.3 inches in length and 36.0 inches in width with a 2.3-inch thickness and weighs 500 pounds. The analysis was completed on July 22, 2021, using AASHTO 6th Edition (2013) standards with a basic wind speed of 90 mph and an importance factor of 0.87.

The structural design calculations indicate maximum axial loads of 5,542.65 pounds, maximum shear of 1,610.98 pounds, and a calculated moment of 71.49 k-ft for Pole A. The foundation design specifies a 36-inch diameter foundation with 12.5 feet of soil volume (3.3 cubic yards) and 6.0 feet of rock volume (1.6 cubic yards) at level ground with a 2:1 slope condition. Vertical reinforcement consists of #8 bars (13 total) with #4 spiral ties at 12-inch pitch. The analysis was performed by Ted Swansegar of the Kentucky Department of Transportation and is based on program calculations developed by Florence and Hutcheson, Inc.

View the file

Other files

File Type Posted
Attachment B Shock Hazard Sticker.pdf PDF
Attachment D Handhole.pdf PDF
Attachment A Annual_Affidavit_Rev__August_2020.pdf PDF
Final_RFB_605_2200000056_1_SO_FORM.PDF PDF
Bid Sheet.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

District: 5

County: jefferson

City: louisville

Permit Num:

PM Name:

Project Num: Author: Swansegar, Ted (ted.swansegar@ky.gov)

File Name: D5 overheightdetection

Code Version: AASHTO 6th Edition (2013)

Created: 7/22/2021 2:00:00 PM

Last Edited: 7/22/2021 2:09:00 PM

I. Project Data Used Custom Attachments Data

Department:

Basic Wind Speed: 90.00

Wind Importance: 0.87

Velocity Conversion: 0.93

Ice Load Pressure: Gust Effect: 1.14

II. Design Assumptions 3.00

III. Mast Arm

Disclaimer: The contents of this program were developed for use by Florence and Hutcheson, Inc. The calculations derived from said program should not be used for any application without examination and verification of its accuracy and suitability for such application by professionally qualified personnel. Florence and Hutcheson, Inc. assumes no liability or responsibility for and makes no representations or warranties as to the applicability or suitability of these results and anyone making use thereof or relying thereon assumes all risk and liability arising from such use or reliance. This program does not constitute a standard, specification or regulation.

Pole A

Page 1 of 4AnalysisDetail(RC1)7/22/2021 2:09:46 PM

Salsa Design Analysis (Detail Version)

Pole Attachments Pole Name Height (ft) Align (deg) Length (in) Width (in) Thickness (in) Weight

(lbs) Drag

IV. Pole Inputs

Vertical Pole Info Pole Height

(ft) Base (in) Top (in) Thickness

(in) Cd Directionality

Coefficient

A 21.50 18.50 15.49 0.37 0.79 0.95

Mast Arms Length

(ft) Height

(ft) Seg1

Length (ft)

Seg1 Base (in)

Seg1 Taper

Seg1 Thickness

(in)

Seg2 Base (in)

Seg2 Taper

Seg2 Thickness

(in)

35.0000 19.0000 N/A 13.7500 0.1400 0.2500 N/A 0.1400 N/A

35.0000 19.0000 N/A 13.7500 0.1400 0.2500 N/A 0.1400 N/A

Luminaire Arms Length

(ft) Height

(ft) Seg1

Length (ft)

Seg1 Base (in)

Seg1 Taper

Seg1 Thickness

(in)

Seg2 Base (in)

Seg2 Taper

Seg2 Thickness

(in)

Arms & Arm Attachments Arm Arm Attachment Pole Name Length (ft) Height

(ft) Align (deg)

Type Length (in)

Width (in)

Thickness (in)

Weight (lbs)

Drag Distance (ft)

A overheight 35.0 19.0 0.0 User - Custom

102.3 36.0 2.3 500.0 1.1 30.0

A overheight 35.0 19.0 90.0 User - Custom

102.3 36.0 2.3 500.0 1.1 30.0

Page 2 of 4AnalysisDetail(RC1)7/22/2021 2:09:46 PM

VII. Pole Results

Axial (lb) Shear (lb) Calculated Moment (k-ft)

Group I 4,481.03 0.00 43.15

Group II 4,481.03 1,610.98 70.07

Group III 5,542.65 1,144.99 71.49

Pole A

0.00

0.00

0.00

Torsion (k-ft)

Page 3 of 4AnalysisDetail(RC1)7/22/2021 2:09:46 PM

VIII. Design Summary

Pole Loads Pole

Number Max Axial (lb) Max Shear

(lb) Calculated

Moment (k-ft) Torsion (k-ft)

A 5,542.65 1,610.98 71.49 0.00

Foundation Design Level Ground 2:1 Ground Slope Vertical Bars Ties or Spiral

Pole Number

Diameter (inches)

Soil (feet) Volume

(CY)

Rock (feet)

Volume

(CY)

Soil (feet) Volume

(CY)

Rock (feet)

Volume

(CY)

Size Total Size Pitch

A 36.0 12.5 3.3 6.0 1.6 13.50 3.5 6.00 1.6 #8 13 #4 12.00

Page 4 of 4AnalysisDetail(RC1)7/22/2021 2:09:46 PM

File details come from the government source that posted it. Updated .