This is a structural design analysis document prepared by the Kentucky Department of Transportation, District 5, for an overheight detection signal support structure located in Louisville, Jefferson County. The project involves the design and analysis of a 21.5-foot vertical pole (Pole A) with two mast arms extending 35 feet in length at a height of 19 feet, each measuring 102.3 inches long by 36 inches wide by 2.3 inches thick with a weight of 500 pounds. The analysis was conducted using AASHTO 6th Edition (2013) design standards and was created on July 22, 2021, by Ted Swansegar of the Kentucky Transportation Cabinet. The document includes calculations for wind loads with a basic wind speed of 90 miles per hour, an importance factor of 0.87, and a gust effect factor of 1.14.
The design analysis reveals maximum pole loads of 5,542.65 pounds axial force, 1,610.98 pounds shear force, and a calculated moment of 71.49 kip-feet with zero torsion. The foundation design specifies a 36-inch diameter foundation with 12.5 feet of soil and 6.0 feet of rock depth, with a total volume of 3.3 cubic yards of soil and 1.6 cubic yards of rock excavation. Vertical reinforcement consists of #8 bars totaling 13 bars with #4 ties at 12-inch pitch. The document includes a professional disclaimer from Florence and Hutcheson, Inc., indicating that all calculations and results are subject to examination and verification by qualified personnel before implementation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment B Shock Hazard Sticker.pdf | ||
| Final_RFB_605_2200000079_1_SO_FORM.PDF | ||
| Bid Sheet.xlsx | XLSX spreadsheet | |
| Attachment A Annual_Affidavit_Rev__August_2020.pdf | ||
| Attachment D Handhole.pdf | ||
| How to Respond to Online Bid through Kentucky Vendor Self....pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
District: 5
County: jefferson
City: louisville
Permit Num:
PM Name:
Project Num: Author: Swansegar, Ted (ted.swansegar@ky.gov)
File Name: D5 overheightdetection
Code Version: AASHTO 6th Edition (2013)
Created: 7/22/2021 2:00:00 PM
Last Edited: 7/22/2021 2:09:00 PM
I. Project Data Used Custom Attachments Data
Department:
Basic Wind Speed: 90.00
Wind Importance: 0.87
Velocity Conversion: 0.93
Ice Load Pressure: Gust Effect: 1.14
II. Design Assumptions 3.00
III. Mast Arm
Disclaimer: The contents of this program were developed for use by Florence and Hutcheson, Inc. The calculations derived from said program should not be used for any application without examination and verification of its accuracy and suitability for such application by professionally qualified personnel. Florence and Hutcheson, Inc. assumes no liability or responsibility for and makes no representations or warranties as to the applicability or suitability of these results and anyone making use thereof or relying thereon assumes all risk and liability arising from such use or reliance. This program does not constitute a standard, specification or regulation.
Pole A
Page 1 of 4AnalysisDetail(RC1)7/22/2021 2:09:46 PM
Salsa Design Analysis (Detail Version)
Pole Attachments Pole Name Height (ft) Align (deg) Length (in) Width (in) Thickness (in) Weight
(lbs) Drag
IV. Pole Inputs
Vertical Pole Info Pole Height
(ft) Base (in) Top (in) Thickness
(in) Cd Directionality
Coefficient
A 21.50 18.50 15.49 0.37 0.79 0.95
Mast Arms Length
(ft) Height
(ft) Seg1
Length (ft)
Seg1 Base (in)
Seg1 Taper
Seg1 Thickness
(in)
Seg2 Base (in)
Seg2 Taper
Seg2 Thickness
(in)
35.0000 19.0000 N/A 13.7500 0.1400 0.2500 N/A 0.1400 N/A
35.0000 19.0000 N/A 13.7500 0.1400 0.2500 N/A 0.1400 N/A
Luminaire Arms Length
(ft) Height
(ft) Seg1
Length (ft)
Seg1 Base (in)
Seg1 Taper
Seg1 Thickness
(in)
Seg2 Base (in)
Seg2 Taper
Seg2 Thickness
(in)
Arms & Arm Attachments Arm Arm Attachment Pole Name Length (ft) Height
(ft) Align (deg)
Type Length (in)
Width (in)
Thickness (in)
Weight (lbs)
Drag Distance (ft)
A overheight 35.0 19.0 0.0 User - Custom
102.3 36.0 2.3 500.0 1.1 30.0
A overheight 35.0 19.0 90.0 User - Custom
102.3 36.0 2.3 500.0 1.1 30.0
Page 2 of 4AnalysisDetail(RC1)7/22/2021 2:09:46 PM
VII. Pole Results
Axial (lb) Shear (lb) Calculated Moment (k-ft)
Group I 4,481.03 0.00 43.15
Group II 4,481.03 1,610.98 70.07
Group III 5,542.65 1,144.99 71.49
Pole A
0.00
0.00
0.00
Torsion (k-ft)
Page 3 of 4AnalysisDetail(RC1)7/22/2021 2:09:46 PM
VIII. Design Summary
Pole Loads Pole
Number Max Axial (lb) Max Shear
(lb) Calculated
Moment (k-ft) Torsion (k-ft)
A 5,542.65 1,610.98 71.49 0.00
Foundation Design Level Ground 2:1 Ground Slope Vertical Bars Ties or Spiral
Pole Number
Diameter (inches)
Soil (feet) Volume
(CY)
Rock (feet)
Volume
(CY)
Soil (feet) Volume
(CY)
Rock (feet)
Volume
(CY)
Size Total Size Pitch
A 36.0 12.5 3.3 6.0 1.6 13.50 3.5 6.00 1.6 #8 13 #4 12.00