This notice requests Standard Form 330 submissions from architect-engineering firms for design services. Required services include developing construction documents and specifications to modify space for new sterile processing equipment at the Durham VA Medical Center in North Carolina. Submissions are due February 28, 2024. The project value is estimated between $500,000 to $1 million. Design completion is due 190 days after notice to proceed, with construction period services through 365 days after construction award. Evaluation criteria prioritize relevant hospital project experience within the last five years, technical competence, past performance, and location. The solicitation is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment A - Floor Plan.pdf | ||
| 36C24624R0047.docx | DOCX document | |
| Attachment B - Department Survey.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VHADURCazalL Text Box
ATTACHMENT C
VHADURCazalL Text Box Equipment Data Sheets > Triton 36 - Getinge Sonic Cleaner > 2460U - Getinge Sonic Cleaner > 9128E - Getinge Cart Washer > 733HC-E - Getinge Steam Sterilizer > GSS67N13 - Getinge Steam Sterilizer > 8668 - Getinge Instrument Washer Disinfector > 9668 - Getinge Return Conveyor > Loader & Unloader fro Washer Disinfector
VHADURCazalL Stamp
GETINGE Model Triton 36 Ultrasonic Cleaner
Construction Rough-In Drawings
*Photo may not represent actual model
Getinge Group 1 Geoffrey Way
Wayne, NJ 07470 United States
Dwg. 9756-005, Rev E
JULY-21
Getinge Surgical Workplaces
Disinfection and Sterilization Products
Project Responsibilities
Component Designed by/Materials Provided By
Performed By Timing/Project Phase
Getinge
Product specifications, Construction Rough In drawings
GETINGE GETINGE
At time of purchase order or customer signed GETINGE
Drawing Package
General Contractor
Design, Fabrication of space for egress, wall opening, foot print and utility rough-in for each piece of equipment
Customer or General contractor per GETINGE
Construction Rough In drawing
Customer’s Engineer of Record/Architect and General Contractor.
Based upon overall construction schedule
In Wall Chair Carriers GETINGE Customer’s specified General contractor
Based upon overall construction schedule
Plumbing Contractor
Cold Water, Hot Water, RO Water, Steam, Condensate and Air supply lines to within 5 running feet of equipment’s connection point. Drain
Customer or Plumbing contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Plumbing contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
Floor Sinks and/or Drains
Customer or Plumbing contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Plumbing contractor
Based upon overall construction schedule
Ball and Gate Valves for all supply lines with threads for easier connections
Customer or Plumbing contractor using Industry approved valves and materials
Customer’s/GC specified Plumbing contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
Water, Steam, condensate and Air connections between equipment and facility supply lines
GETINGE using GETINGE Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Plumbing contractor During Equipment Installation
Electrical Contractor
Duplex, “J” box and Fused Electrical Disconnect
Customer or Plumbing contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Electrical contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
All branch circuit wiring and conduit (primary and secondary) external to GETINGE supplied equipment
Customer or electrical contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Electrical contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
Electrical final terminations between Utilization
Equipment Outlet boxes and facility power
Customer or electrical contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Electrical
After equipment installation
Mechanical Contractor
Exhaust Ducts and gravity line vents
Customer or Mechanical contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Mechanical contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
All branch duct and gravity line vents
Customer or Mechanical contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Mechanical contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
Installation Contractor (Non-Union)
Uncrating of equipment N/A GETINGE if installation purchased per sales agreement
Based upon overall construction schedule
Equipment Installation N/A GETINGE if installation purchased per sales agreement
During equipment installation phase based on project schedule
Disposal of shipping containers and packing debris to an on installation site customer provided receptacle
N/A
GETINGE if installation purchased per sales agreement
As required during equipment installation phase based on project schedule
Final Installation Checkout N/A GETINGE if installation purchased per sales agreement
After Equipment Installation
In-service
Training of Equipment Operation: cycle selection, start, stop, abort, reset, loading, unloading
GETINGE
Following Equipment Installation
Customer
Receive, off load and storage of equipment in secured protected area N/A
Customer or customer designated shipping contractor
Based upon overall construction schedule
Disposal of any existing equipment
N/A Customer After removal from existing location
Notes
1. Minimum of thirty (30) working days notification will be required for scheduling installation. Additional costs may be billed if less than 30 days’ notice is given.
2. Installation is performed during the hours of 8 a.m. to 5 p.m. excluding weekends and holidays. Overtime charges will apply after 5:00 p.m. and during weekends/holidays.
3. Removal of asbestos or equipment subject to disposal regulations of federal, state or local governments is not included. Pricing must be obtained through local hazardous waste contractors.
4. Pricing does not provide for union labor.
5. Scope of installation work is based upon timely and uninterrupted access, site conditions and utility availability.
Additional visits due to work stoppage beyond the control of Getinge will be billed directly to the buyer at prevailing rates.
6. Purchaser shall provide a site that is compatible to accept the egress of equipment into building, foot print, wall openings, utility supply lines, immediate access valves and which complies with any applicable requirements of any governmental authority.
7. The equipment ordered will be shipped in large crates and ingress into building requires specific height and width.
This includes the path to the final installation location. Dimensions will be provided upon request.
8. If equipment is stored off site, it is the customer’s responsibility to transport equipment to the installation site.
9. Getinge provides layout drawings based on information and/or facility drawings provided. Getinge provides these drawings for reference only to the contractor and architect. It will be the responsibility of the contractor to verify the dimensions for placement within the building based on the required dimensions provided by Getinge.
10. Wall thickness is indicated on the installation/arrangement drawings. For recessed equipment between one or two walls, please pay close attention to the wall thickness indicated to prevent interference with the equipment installation and operation. Wall thickness for the Getinge equipment is vitally important for proper installation, location, fit and function within the facility.
11. Floor protection to protect facility floors during installation is not provided by Getinge.
12. For the purpose of service, Getinge requires adequate permanent lighting in the enclosed service areas of the sterilizer and washer.
13. 120V duplex electrical receptacle recommended in the service area.
9887-001 Rev E, May 31, 2021
AutoCAD SHX Text
FRONT ELEVATION LOAD END
AutoCAD SHX Text
PLAN VIEW
AutoCAD SHX Text
SIDE ELEVATION
AutoCAD SHX Text
FACILITY WALL
AutoCAD SHX Text
FACILITY FLOOR
AutoCAD SHX Text
NET WEIGHT
AutoCAD SHX Text
AutoCAD SHX Text 606 [274.9]
AutoCAD SHX Text
SHIPPING WEIGHT
AutoCAD SHX Text 940 [426.4]
AutoCAD SHX Text D
AutoCAD SHX Text L
AutoCAD SHX Text 49 " 1116" [1262]
AutoCAD SHX Text 24" [610]
AutoCAD SHX Text H
AutoCAD SHX Text 61 " 78" [1572]
AutoCAD SHX Text WEIGHTS Lb [kg]
AutoCAD SHX Text NOTES: 1) ALL DIMENSIONS GIVEN ARE FROM FINISHED SURFACES. 2) ALL DIMENSIONS ARE FEET/INCHES [MILLIMETERS]. 3) DRAWING NOT TO SCALE.
AutoCAD SHX Text
OPERATIONAL WEIGHT
AutoCAD SHX Text 896 [406.4]
AutoCAD SHX Text 5'-5 "34"
AutoCAD SHX Text [1670]
AutoCAD SHX Text 2'-5 "316"
AutoCAD SHX Text [741]
AutoCAD SHX Text 4'-1 "1116"
AutoCAD SHX Text [1262]
AutoCAD SHX Text 5'-1 "78"
AutoCAD SHX Text [1572]
AutoCAD SHX Text 1'-5 "1316"
AutoCAD SHX Text [452]
AutoCAD SHX Text 2'
AutoCAD SHX Text [610]
AutoCAD SHX Text 4'-1 "1116"
AutoCAD SHX Text [1262]
AutoCAD SHX Text 2'
AutoCAD SHX Text [610]
AutoCAD SHX Text
MAXIMUM LOAD
AutoCAD SHX Text 40 lbs (18.1 kg)
AutoCAD SHX Text
LIQUID VOLUME
AutoCAD SHX Text
OVERALL SIZE
AutoCAD SHX Text
ULTRASONIC CHAMBER SPEC
AutoCAD SHX Text
30 GALLONS (113.6L)
AutoCAD SHX Text 11.5"W x 37"D x 19.37"H
AutoCAD SHX Text (294 x 940 x 492)
AutoCAD SHX Text
(PER BASIN)
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SHEET #:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
AN
AutoCAD SHX Text 1/20/20
AutoCAD SHX Text N/A
AutoCAD SHX Text
AutoCAD SHX Text
REV
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text 9756-005 S1
AutoCAD SHX Text
DRAWING NUMBER / FILE NAME:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
(STRUCTURAL)
AutoCAD SHX Text
MODEL TRITON 36 ULTRASONIC CLEANER
AutoCAD SHX Text A
AutoCAD SHX Text
AN
AutoCAD SHX Text 10/27/20
AutoCAD SHX Text
ADD FULL LOAD AMPS.
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
GD
AutoCAD SHX Text 07/28/21
2021 UPDATES
Plumbing Notes: P1.) IT SHALL BE THE CUSTOMER'S RESPONSIBILITY TO INSURE BY USE OF PRESSURE IT SHALL BE THE CUSTOMER'S RESPONSIBILITY TO INSURE BY USE OF PRESSURE REGULATORS OR OTHER MEANS THAT MAXIMUM SPECIFIED PRESSURES ARE NOT EXCEEDED. DYNAMIC PRESSURE IS MEASURED DURING FLOW CONDITIONS. STATIC PRESSURE SHALL NOT EXCEED SPECIFIED VALUES FOR ANY SERVICE CONDITION. PRESSURE TO BE MEASURED AT POINT OF CONNECTION TO THE ULTRASONIC CLEANER. P2.) IT SHALL BE THE CUSTOMER'S RESPONSIBILITY TO ELIMINATE WATER HAMMER IT SHALL BE THE CUSTOMER'S RESPONSIBILITY TO ELIMINATE WATER HAMMER CONDITIONS SHOULD THEY OCCUR IN THE SERVICE PIPING. IF REQUIRED, SHOCK ARRESTORS OR PRESSURE REGULATORS WOULD BE PROVIDED AND INSTALLED BY THE CUSTOMER. P3) IT SHALL BE THE CUSTOMERS RESPONSIBILITY TO PROVIDE SHUTOFF VALVES FOR IT SHALL BE THE CUSTOMERS RESPONSIBILITY TO PROVIDE SHUTOFF VALVES FOR WATER LINES AND A PROPERLY SIZED AND TRAPPED DRAINAGE SYSTEM IN ACCORDANCE WITH THE NATIONAL PLUMBING CODE. CONSIDERATION SHOULD BE IN ACCORDANCE WITH THE NATIONAL PLUMBING CODE. CONSIDERATION SHOULD BE CONSIDERATION SHOULD BE GIVEN TO OTHER EQUIPMENT DUMPING INTO DRAIN LINE TO PREVENT SLOW DRAINAGE, BACK-UP, OR OVERFLOW. P4) IT SHALL BE THE CUSTOMERS RESPONSIBILITY TO ENSURE THAT WATER SUPPLIES IT SHALL BE THE CUSTOMERS RESPONSIBILITY TO ENSURE THAT WATER SUPPLIES ARE PROPERLY PROTECTED FOR INTERNAL CROSS CONNECTION CONTROL IN ACCORDANCE WITH LOCAL BUILDING AND PLUMBING REQUIREMENTS. P4.) INCOMING WATER TEMPERATURES FOR BOTH COLD WATER AND HOT WATER NEED INCOMING WATER TEMPERATURES FOR BOTH COLD WATER AND HOT WATER NEED TO BE IN AN ACCEPTABLE RANGE TO ALLOW THE FACTORY-SUPPLIED MIXING VALVE TO OUTPUT WATER TO THE SONIC IN THE RANGE OF 85'F TO 95'F (29.4'C TO 35'C). P5.) AIR SUPPLY MUST BE DRY, OIL FREE, AND FILTERED. AIR SUPPLY MUST BE DRY, OIL FREE, AND FILTERED. NOTICE: SAFE AND EFFICIENT OPERATION OF THIS PRODUCT IS DEPENDENT UPON THE OWNER/USER PROVIDING THE SERVICES SPECIFIED HEREIN AS WELL AS ANY OTHER NORMALLY ACCEPTED ELECTRICAL, MECHANICAL OR PLUMBING INTERFACE BETWEEN USER'S SUPPLY AND THIS PRODUCT. GETINGE USA WILL NOT ASSUME RESPONSIBILITY FOR PROBLEMS THAT RESULT FROM NON-COMPLIANCE WITH THE ABOVE CONDITIONS. THE FOLLOWING CONDITIONS AND SERVICES ARE REQUIRED FOR GETINGE USA EQUIPMENT AND ARE TO BE PROVIDED BY OTHERS.
AutoCAD SHX Text =COLD WATER 15-60 PSi 1 GPM (3.758L) 30 GAL/PHASE 15-60 PSi 1 GPM (3.758L) 30 GAL/PHASE 1 GPM (3.758L) 30 GAL/PHASE 30 GAL/PHASE 3/4" GARDEN HOSE (113.6 LITERS) (113.6 LITERS) (113.6 LITERS) (113.6 LITERS) (113.6 LITERS) =HOT WATER 15-60 PSi 1 GPM (3.758L) 30 GAL/PHASE 15-60 PSi 1 GPM (3.758L) 30 GAL/PHASE 1 GPM (3.758L) 30 GAL/PHASE 30 GAL/PHASE 3/4" GARDEN HOSE (113.6 LITERS) (113.6 LITERS) (113.6 LITERS) (113.6 LITERS) =PURIFIED WATER 15-60 PSi N/A 30 GAL/PHASE 15-60 PSi N/A 30 GAL/PHASE N/A 30 GAL/PHASE 30 GAL/PHASE 1/4"(6.35mm) NPT FEMALE (113.6 LITERS) (113.6 LITERS) (113.6 LITERS) =DRAIN 10 GPM WASTE LINE N/A N/A 10 GPM WASTE LINE N/A N/A 10 GPM WASTE LINE N/A N/A N/A 5/8" ID (15.875mm) =AIR SUPPLY 60-90 PSi 1 CFM N/A 60-90 PSi 1 CFM N/A 1 CFM N/A N/A N/A 1/4"(6.35mm) NPT FEMALE =DETERGENT N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
AutoCAD SHX Text
ON UNIT CONNECTION
AutoCAD SHX Text
PRESSURE RANGE
AutoCAD SHX Text
DEMAND
AutoCAD SHX Text
CONSUMPTION
AutoCAD SHX Text
REQUIRED FOR
AutoCAD SHX Text
ALL UNITS
AutoCAD SHX Text
ALL UNITS
AutoCAD SHX Text
ALL UNITS
AutoCAD SHX Text
ALL UNITS
AutoCAD SHX Text
CW
AutoCAD SHX Text
HW
AutoCAD SHX Text
PW
AutoCAD SHX Text A
AutoCAD SHX Text
DT
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text
REAR ELEVATION
AutoCAD SHX Text
PLAN VIEW
AutoCAD SHX Text
PW
AutoCAD SHX Text
HW
AutoCAD SHX Text
CW
AutoCAD SHX Text A
AutoCAD SHX Text
DT
AutoCAD SHX Text D
AutoCAD SHX Text
PW
AutoCAD SHX Text
HW
AutoCAD SHX Text
CW
AutoCAD SHX Text A
AutoCAD SHX Text
DT
AutoCAD SHX Text
RELATIVE HUMIDITY
AutoCAD SHX Text
0 TO 75%%%
AutoCAD SHX Text
PRESSURE
AutoCAD SHX Text
TEMPERATURE
AutoCAD SHX Text
OPERATING ENVIRONMENTAL CONDITIONS
AutoCAD SHX Text 0-6500' (0-1981M)
AutoCAD SHX Text
SEA LEVEL FROM
AutoCAD SHX Text
5%%DC (41%%DF) TO 40%%DC (104%%DF)
AutoCAD SHX Text 7 "34"
AutoCAD SHX Text [197]
AutoCAD SHX Text 10"
AutoCAD SHX Text [254]
AutoCAD SHX Text 11"
AutoCAD SHX Text [279]
AutoCAD SHX Text 1 "34"
AutoCAD SHX Text [44]
AutoCAD SHX Text 3 "38"
AutoCAD SHX Text [86]
AutoCAD SHX Text 8 "34"
AutoCAD SHX Text [222]
AutoCAD SHX Text 9 "34"
AutoCAD SHX Text [248]
AutoCAD SHX Text 11 "34"
AutoCAD SHX Text [299]
AutoCAD SHX Text
ALL UNITS
AutoCAD SHX Text
ALL UNITS
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SHEET #:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
AN
AutoCAD SHX Text 1/20/20
AutoCAD SHX Text N/A
AutoCAD SHX Text
AutoCAD SHX Text
REV
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
DRAWING NUMBER / FILE NAME:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text 9756-005 P1
AutoCAD SHX Text
(PLUMBING)
AutoCAD SHX Text
MODEL TRITON 36 ULTRASONIC CLEANER
AutoCAD SHX Text A
AutoCAD SHX Text
AN
AutoCAD SHX Text 10/27/20
AutoCAD SHX Text
ADD FULL LOAD AMPS.
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SEE SHEET 1
NOTES: E1.) IT SHALL BE THE CUSTOMER'S RESPONSIBILITY TO COMPLETE ALL ELECTRICAL CONNECTIONS USING PROPERLY SIZED WIRING IN IT SHALL BE THE CUSTOMER'S RESPONSIBILITY TO COMPLETE ALL ELECTRICAL CONNECTIONS USING PROPERLY SIZED WIRING IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE.
AutoCAD SHX Text E1
AutoCAD SHX Text
REAR ELEVATION
AutoCAD SHX Text
PLAN VIEW
AutoCAD SHX Text E1
AutoCAD SHX Text 8"
AutoCAD SHX Text [203]
AutoCAD SHX Text
FREQUENCY
AutoCAD SHX Text 40 kHz
AutoCAD SHX Text
GENERATOR
AutoCAD SHX Text
TRANSDUCER TYPE
AutoCAD SHX Text
ULTRASONIC TRANSDUCER'S
AutoCAD SHX Text
2400 WATTS (1200 EACH)
AutoCAD SHX Text
TITANIUM ROD (QTY. 2)
AutoCAD SHX Text
OUTPUT
AutoCAD SHX Text
STRAIGHT BLADE (NEMA 6-20R)
AutoCAD SHX Text 1 "38"
AutoCAD SHX Text [35]
AutoCAD SHX Text =ELECTRICAL CIRCUIT RATING FULL LOAD AMPS CIRCUIT RATING FULL LOAD AMPS FULL LOAD AMPS 208V 60 Hz 20A 9.6A 20A 9.6A 9.6A
AutoCAD SHX Text
ALL UNITS
AutoCAD SHX Text E1
AutoCAD SHX Text
REQUIRED FOR
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SHEET #:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
AN
AutoCAD SHX Text 1/20/20
AutoCAD SHX Text N/A
AutoCAD SHX Text
AutoCAD SHX Text
REV
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
DRAWING NUMBER / FILE NAME:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text 9756-005 E1
AutoCAD SHX Text
(ELECTRICAL)
AutoCAD SHX Text
MODEL TRITON 36 ULTRASONIC CLEANER
AutoCAD SHX Text A
AutoCAD SHX Text
AN
AutoCAD SHX Text 10/27/20
AutoCAD SHX Text
ADD FULL LOAD AMPS.
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SEE SHEET 1
Equipment Data Sheet 9128E - Getinge Cart Washer
GETINGE Cart Washer Model 9128E – Floor Mounted –
Steam Heated Construction Rough-In Drawings
*Photo may not represent actual model
Getinge Group 1 Geoffrey Way
Wayne, NJ 07470 United States
Dwg. 9428-023 FM, Rev E 10-15-21
Construction Rough In drawings
GETINGE GETINGE
At time of purchase order or for egress, wall opening, foot print and utility rough-in for each piece of equipment
Customer or General contractor per GETINGE
Construction Rough In drawing
Customer’s Engineer of Record/Architect and General Contractor.
Based upon overall construction schedule
In Wall Chair Carriers GETINGE Customer’s specified General contractor
Water, Steam, Condensate and Air supply lines to within 5 running feet of equipment’s connection point. Drain
Customer or Plumbing contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Plumbing contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
Floor Sinks and/or Drains
Customer or Plumbing contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Plumbing contractor
Based upon overall construction schedule
Ball and Gate Valves for all supply lines with threads for easier connections
Customer or Plumbing contractor using Industry approved valves and materials
Customer’s/GC specified Plumbing contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
Water, Steam, condensate and Air connections between equipment and facility supply lines
GETINGE using GETINGE Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Plumbing
Electrical Disconnect
Customer or Plumbing contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Electrical contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
All branch circuit wiring and conduit (primary and secondary) external to GETINGE supplied equipment
Customer or electrical contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Electrical contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
Electrical final terminations between Utilization
Equipment Outlet boxes and facility power
Customer or electrical contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Electrical line vents Customer or Mechanical contractor using GETINGE Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Mechanical contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
All branch duct and gravity line vents
Customer or Mechanical contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Mechanical contractor
While ceilings and walls are open during
GETINGE if installation purchased per sales agreement
Based upon overall construction schedule
Equipment Installation N/A GETINGE if installation purchased per sales agreement
During equipment installation phase based on project schedule Disposal of shipping containers and packing debris to an on installation site customer provided receptacle
N/A
GETINGE if installation purchased per sales agreement
As required during equipment installation phase based on project schedule
Final Installation Checkout N/A GETINGE if installation purchased
Operation: cycle selection, GETINGE GETINGE Following Equipment of equipment in secured protected area N/A
Customer or customer designated shipping contractor
Based upon overall construction schedule
Disposal of any existing equipment N/A Customer After removal from existing
1. Minimum of thirty (30) working days notification will be required for scheduling installation. Additional costs may be billed if less than 30 days’ notice is given.
2. Installation is performed during the hours of 8 a.m. to 5 p.m. excluding weekends and holidays. Overtime charges will apply after 5:00 p.m. and during weekends/holidays.
3. Removal of asbestos or equipment subject to disposal regulations of federal, state or local governments is not included. Pricing must be obtained through local hazardous waste contractors.
4. Pricing does not provide for union labor.
5. Scope of installation work is based upon timely and uninterrupted access, site conditions and utility availability.
Additional visits due to work stoppage beyond the control of Getinge will be billed directly to the buyer at prevailing rates.
6. Purchaser shall provide a site that is compatible to accept the egress of equipment into building, foot print, wall openings, utility supply lines, immediate access valves and which complies with any applicable requirements of any governmental authority.
7. The equipment ordered will be shipped in large crates and ingress into building requires specific height and width.
This includes the path to the final installation location. Dimensions will be provided upon request.
8. If equipment is stored off site, it is the customer’s responsibility to transport equipment to the installation site.
9. Getinge provides layout drawings based on information and/or facility drawings provided. Getinge provides these drawings for reference only to the contractor and architect. It will be the responsibility of the contractor to verify the dimensions for placement within the building based on the required dimensions provided by Getinge.
10. Wall thickness is indicated on the installation/arrangement drawings. For recessed equipment between one or two walls, please pay close attention to the wall thickness indicated to prevent interference with the equipment installation and operation. Wall thickness for the Getinge equipment is vitally important for proper installation, location, fit and function within the facility.
11. Floor protection to protect facility floors during installation is not provided by Getinge.
12. For the purpose of service, Getinge requires adequate permanent lighting in the enclosed service areas of the
Service Door
LOAD END
(RH)
LOAD END
(LH)
5'-13 4 Center of Mass
[1569 MM]
11' Unit Length
[3353.8 MM]
20'-8" Tot. Length Unit With Ramps
[6299.2 MM]
4'-101 8" Ramp Length
[1476 MM]
8' -1
01 2" M in . H ei gh t I nn er R oo f
[2
M
M
9'-9" Tot. Width Trim Panel
[2972 MM]
4' -9
D is pl ay [1
7.
8M M
3' -6
[1
M M
11' Finish Face to Finish Face
[2501.9MM]
4.75"
[120.65MM]
10'" WALL OPENING
[3048 MM]
9' -5
" W
AL
L O
PE
N
IN
G
[2
M
M
9' -4
1 8" U ni t H ei gh t [2
M M
' W
AL
L
O
PE
N
IN
G [3
M M
Cover Strips built by others!
1"
[24.5MM]
Note!
it is preferable to place service door on soiled side but can also mount on clean side if required.
Service door clearance shall not be less than
19.75 inch.
NOTES:
1) ALL DIMENSIONS GIVEN ARE FROM FINISHED SURFACES.
2) ALL DIMENSIONS ARE IMPERIAL AND [METRIC].
3) DRAWING NOT TO SCALE.
5) SOUND LEVEL VALUE IS VALID WHEN WASHER AND SERVICE
AREA ARE BUILT IN. MEASURED 1 METER IN FRONT OF THE
WASHER AND 1.5 METER ABOVE FLOOR LEVEL.
6) "LH" REFERS TO LEFT HAND CONTROLS ON THE LOAD END,
"RH" REFERS TO RIGHT HAND CONTROLS ON THE LOAD END.
7) FOR AIR-BARRIER OPTION SEE DRAWING 9428-025
'-5
" A
FF
[3
9.
8M
M
9' -5
3 4" A
FF
[2
8.
M
M
CW
HW
PW S CW HW PW SEX EX
6'-31 2"
[1917.7MM]
6'-7"
[2006.6MM]
7'-65
8"
[2301.8MM]
E
9'-0"
[2743.2MM]
*SITE UTILITY DROP RECOMMENDATION*
N N
EFINISHED
CEILING
CW = COLD WATER
CA = COMPRESSED AIR
PW = PURIFIED WATER
HW = HOT WATER
S = STEAM
C = CONDENSATE
D = PROCESS DRAIN
E = ELECTRICAL
N = NETWORK
UTILITY SIZE TO UNIT
1-1/4" 1-1/4" 1-1/4"
1-1/4"
1/2"
FLOOR SINK W/ 3" DRAIN
NA
RJ45
#2-0/6
REQUIRED SUPPLY
30-60 psi (2-4 BAR)
5 psi (0.3 BAR)
SHEET REFERENCE
PAGE 5 (E1)
PAGE 4 (P1)
PAGE 5 (E1)
PAGE 2 (M1)EX = EXHAUST
30-60 psi (2-4 BAR) 30-60 psi (2-4 BAR)
8" DIA. DUCT 600CFM
100 MBIT/S
80-100 psi (5.5-7 BAR)
45-60 psi (3-4 BAR)
NA
C
E1 E1
E1 = ELECTRICAL PAGE 5 (E1)12 GA 120V
2'-6 58"
[762MM]
2'-10 18"
[866.8MM]
3'-1 58"
[955.7MM]
5'-71 8"
7'-3 78"
[1978MM]
6'-3 58"
[1920.9MM]
[1705MM]
AutoCAD SHX Text
SERVICE SIDE ELEVATION
AutoCAD SHX Text
FRONT ELEVATION LOAD END(LH)/UNLOAD(RH) - W/ TRIM KIT
AutoCAD SHX Text
FRONT ELEVATION LOAD END(LH)/UNLOAD END(RH)
AutoCAD SHX Text
PLAN VIEW
AutoCAD SHX Text
SERVICE SIDE ELEVATION
AutoCAD SHX Text
FRONT ELEVATION LOAD END(LH)/UNLOAD(RH) - W/ TRIM KIT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
REV
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
OF
AutoCAD SHX Text A
AutoCAD SHX Text
ADJUST WALL OPENING DIM/CHANGE TRANSFORMER WIRE GA.
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
SHEET #:
AutoCAD SHX Text
REVISION LEVEL:
AutoCAD SHX Text
DRAWING NUMBER:
AutoCAD SHX Text
ANTONIO N.
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text N/A
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text A
AutoCAD SHX Text
SIZE
AutoCAD SHX Text S1
AutoCAD SHX Text
AN
AutoCAD SHX Text 7/27/18
AutoCAD SHX Text
9428-023 FM
AutoCAD SHX Text CART WASHER, MODEL 9128E STEAM HEATED, FLOOR MOUNTED. (STRUCTURAL) ROUGH-IN DRAWING
AutoCAD SHX Text B
AutoCAD SHX Text
UPDATE EXHAUST DESIGN.
AutoCAD SHX Text
AN
AutoCAD SHX Text 4/30/20
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
2021 UPDATES
AutoCAD SHX Text
TDL
10/15/21
LOAD END
(RH)
LOAD END
(LH)
Openable Service Hatches
7' -2
1 2" [2
M M
] F lo or to s er vi ce
H at ch
'-5
1 2" F re e
Sp ac e Ab ov e
[3
7.
M M
3'-13 4" Door Opening
[959 MM]
6' -6
3 4" D oo r O pe ni ng [2
M M
4" (EX)
[99 MM]
NOTES:
THE ROOM IN WHICH THE VENTILATION IS INSTALLED MUST HAVE A NON
RECIRCULATION VENTILATION SYSTEM.THE EXHAUST CONNECTION TO THE
MACHINE SHALL HAVE AN AIR GAP THAT PREVENTS DRAINING OF ENERGY
FROM THE CHAMBER. AN APPROPRIATE AIR GAP IS 2" SPHERICAL AROUND
THE EXHAUST POINT OF THE CONDENSATE COLLECTOR. THE CONDENSATE
COLLECTOR CAN WHEN NEEDED BE MOVED TO ANOTHER APPROPRIATE
POSITION. ONE EXAMPLE IS WHEN THE ROOF HEIGHT IS TO LOW OR FOR
OTHER PHYSICAL OBSTACLES THAT CAUSE LIMITATIONS. VERY IMPORTANT IS
THAT THE EXTENDED PIPING HAS A SLOPE AGAINST THE REPOSITIONED
CONDENSATE COLLECTOR. THE VENT SHOULD BE DEDICATED, CORROSION
PROOF AND WATER TIGHT. STAINLESS STEEL IS RECOMMENDED.
BASE VENTILATION
ENERGY LOSS DURING NORMAL OPERATION SEE INSTALLATION
MANUAL SECTION 4.3.2 ENERGY EMISSION.
ADDITIONAL VENTILATION DURING DRYING
1. STANDARD PERFORMANCE DRYER: 247.20ft /min (420m³/h) EXHAUST AIR.
2. HIGH PERFORMANCE DRYER: 341.38ft /min (580M³/h) EXHAUST AIR.
FOR MORE DETAILS, SEE INSTALLATION MANUAL SECTION 4.3.3
THE ENERGY OF THE EMITTED AIR DURING PHASE.
SIGNAL AVAILABLE IF CUSTOMER NEED TO CONTROL THE VENTILATION
FROM THE WASHER, SEE INSTALLATION MANUAL SECTION 9.1 (PARAMETER
33 DRYER DELAY ) AND CIRCUIT DIAGRAMS SHEET 48 (PROCESS RUNNING).
EX=Air Exhaust (1019 m ³/h ) 50-100% Air Humidity Pos./ Description Connections Flow Comments
600 cfm
³ ³
5'-71 2" Cover Plate
[1714.5 MM]
CL
Openable service hatch
Openable service hatch
1'-10"
[558MM]
12"
[305MM]
Openable service hatch
5' -2
EX
[1
M M
5' -7
3 4" D
O O
R P
U
LL
EY
E
N D
[1
0.
8M
M
8' -5
" D oo r R ai lin g
H ei gh t
[2
5.
4M
M
EX.
Note!
Facility exhaust duct size to be 12" maximum.
must be less than exhaust condensate catch pan diameter.
2' -4
3 4" [7
M
M
2" (50MM) MINIMUM AIR GAP
TO EXTERNAL VENTILATION
Ø8" MAX(Ø203MM)
9' -3
3 4" A ir Ex ha us t [3
M M
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
REV
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
SHEET #:
AutoCAD SHX Text
REVISION LEVEL:
AutoCAD SHX Text
DRAWING NUMBER:
AutoCAD SHX Text
ANTONIO N.
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text N/A
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text A
AutoCAD SHX Text
SIZE
AutoCAD SHX Text M1
AutoCAD SHX Text A
AutoCAD SHX Text
ADJUST WALL OPENING DIM/CHANGE TRANSFORMER WIRE GA.
AutoCAD SHX Text
AN
AutoCAD SHX Text 7/27/18
AutoCAD SHX Text
9428-023 FM
AutoCAD SHX Text CART WASHER, MODEL 9128E STEAM HEATED, FLOOR MOUNTED. (MECHANICAL) ROUGH-IN DRAWING
AutoCAD SHX Text B
AutoCAD SHX Text
UPDATE EXHAUST DESIGN.
AutoCAD SHX Text
AN
AutoCAD SHX Text 4/30/20
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
2021 UPDATES
AutoCAD SHX Text
TDL
MAX OUTSIDE SURFACE
TEMPERATURE 122°F (50°C)
HUMIDITY HUMIDITY DROPPING TO LESS THAN 40% AFTER
APPROX. 5 MIN OPERATION
SOUND LEVEL. APPROX 65 dB (A)
RADIANT HEAT LOSS CLEAN SIDE 2,25 KW/HR (7700 BTU /HR)
SOILED SIDE 0,90 KW/HR (3100 BTU/HR)
SERVICE AREA 1,35 KW/HR (4600 BTU/HR)
POWER CONSUMPTION STEAM HEATED MAX 6 KW
TEMPERATURE 5°C (41°F) TO 40°C (104°F)
RELATIVE HUMIDITY MAX 80% AT ≤31°C THEN DECREASING LINEARLY TO
50% WHEN TEMPERATURE IS INCREASING TO 40°C
VOLTAGE FLUCTUATIONS
(MAIN SUPPLY) NOT TO EXCEED ±10% OF THE NOMINAL VOLTAGE
INPUT CONDITIONS
OPERATING ENVIROMENTAL CONDITIONS
DIMENSION
(INCH)
WEIGHT
(LB)
DIMENSION
(INCH)
WEIGHT
(LB)
DIMENSION
(INCH)
WEIGHT
(LB)
WEIGHT
(LB)
CORE MODULE
CHAMBER
EXTENSION
MODULE (2x)
GLASS DOOR (2x)
TOTAL WEIGHT
DIMENSION AND WEIGHT (EXCL. PACKAGING)
9128E 53x96x47
52x96x33
43x83x1,5
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
REV
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
SHEET #:
AutoCAD SHX Text
REVISION LEVEL:
AutoCAD SHX Text
DRAWING NUMBER:
AutoCAD SHX Text
ANTONIO N.
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text N/A
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text A
AutoCAD SHX Text
SIZE
AutoCAD SHX Text M2
AutoCAD SHX Text A
AutoCAD SHX Text
ADJUST WALL OPENING DIM/CHANGE TRANSFORMER WIRE GA.
AutoCAD SHX Text
AN
AutoCAD SHX Text 7/27/18
AutoCAD SHX Text
9428-023 FM
AutoCAD SHX Text
CART WASHER, MODEL 9128E STEAM HEATED, FLOOR MOUNTED. (NOTES) ROUGH-IN DRAWING
AutoCAD SHX Text B
AutoCAD SHX Text
UPDATE EXHAUST DESIGN.
AutoCAD SHX Text
AN
AutoCAD SHX Text 4/30/20
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
2021 UPDATES
AutoCAD SHX Text
TDL
C
S
LOAD END
(RH)
LOAD END
(LH)
CA
9' -1
01 4" S te am
[3
3.
M M
2'-11" CA
[887 MM]
D2'-91
2" (HW, CW, DW)
[851 MM]
CW
HW
DW
8' -2
H
W , C
W , D
W
[2
3.
M M
2' - 01 2" C
[622MM]
CW
HW
DW
3'-8" Center of Mass
[1117.6 MM]
2'-6" Steam
[762MM]
CL
CL
2'-13
4" DW
[654MM]
2'-51
4" HW
[743MM]
2'-9" CW
[838MM]
CW
D
C
S
CA
PW
HW
1-1/4"
1-1/4"
1-1/4"
1/2"
FLOOR SINK WITH
MINIMUM Ø3" DRAIN LINE
1-1/4"
PIPE SIZE TO UNITON UNIT CONNECTION
UNIT SUPPLIED WITH 3/4" NPT CONNECTION PKG
DRAIN COOLING
UNIT SUPPLIED WITH 3/4" NPT CONNECTION PKG
IF THIS OPTION IS SELECTED, UNIT SUPPLIED WITH
3/4" NPT CONNECTION PKG32 gallons (120 L)
DYNAMIC STEAM PRESSURE. DEPENDANT ON WASHER
3/4" TRI-CLAMP
3/4" TRI-CLAMP
3/4" TRI-CLAMP
MIN. 26 GPM
(100 L/MIN)
MIN. 26 GPM
(100 L/MIN)
MIN. 26 GPM
(100 L/MIN)
30-60 psi
(2-4 BAR)
30-60 psi
(2-4 BAR)
NA
80 gallons (303 L)
NA
Ø3" [Ø80] FLOOR DRAIN
TEMP MAX. 140°F [60 °C] WITH DRAIN COOLING
AIR FREE FROM OIL AND WATER
CONNECTION POINT AT FLOOR LEVEL
COMMENTS
95 lb (42 kg)
MINIMUM
= COMPRESSED AIR
= PURIFIED WATER
(OPTION)
= HOT WATER
113-140°F [45-60°C]
= STEAM 800 lb/h (363 kg/hr)
= CONDENSATE NA
MIN. 50 GPM(200 L/MIN)= PROCESS DRAIN NA
NOT TO EXCEED
5 psi (0.3 BAR)
1/4" NPT
Ø2" [Ø50]
1" NPT
3/4" FPT
0.9 SCFM (25L/min)
= COLD WATER
NOT TO EXCEED
70°F [21°C]"
30-60 psi
(2-4 BAR)
UTILITY
PRESSURE REC.
SUPPLY 9100 DEMAND
9100E CONSUMPTION
PER CYCLE
16 gallons (60 L)
64 gallons (240 L)
80-100 psi
(5.5-7 BAR)
45-60 psi
(3-4 BAR)
*RECOMMENDED*
CONFIGURATION AND WASH CYCLES.
3/4"
(DYNAMIC)
STATIC
NOTES:
1) IT SHALL BE THE CUSTOMERS RESPONSIBILITY TO ENSURE BY USE OF PRESSURE
REGULATORS OR OTHER MEANS THAT MAXIMUM SPECIFIED PRESSURES ARE NOT
EXCEEDED.
2) IT SHALL BE THE CUSTOMERS RESPONSIBILITY TO ELIMINATE WATER OR STEAM
HAMMER CONDITIONS SHOULD THEY OCCUR IN THE SERVICE PIPING.
3) IT SHALL BE THE CUSTOMERS RESPONSIBILITY TO PROVIDE A PROPERLY SIZED
AND LOCATED DRAINAGE SYSTEM IN ACCORDANCE WITH THE NATIONAL PLUMBING
CODE. CONSIDER WHAT OTHER EQUIPMENT IS TIED TO DRAIN TO ELIMINATE SLOW
DRAINAGE OR BACKUP. IF SITE CONDITIONS DICTATE THAT THE WASHER WILL
DUMP WATER DIRECTLY TO PIT, THE PIT SHOULD BE WATER-PROOFED.
4) DYNAMIC STEAM PRESSURE. STEAM DEMAND IS DEPENDING ON WASHER CONFIGURATION
AND WASH CYCLES.
5) IN ACCORDANCE WITH ISO15883-1, GETINGE RECOMMENDS THE USE OF TREATED
WATER WITH THE FOLLOWING LIMIT VALUES:
(UNLESS CONDENSATE
COOLING KIT IS USED)
POTABLEUNIT OFPARAMETER SOFTENED DI/ROMEASURE
PH-VALUE
HARDNESS
CONDUCTIVITY (@25°C)
CHLORINE (CL)
IRON
COPPER
SILICA (SiO )
FREE CHLORINE
PHOSPHATE (P O )
mg/L μS/cm mg/L mg/L mg/L mg/L mg/L mg/L
<100
<200
<60
<0.1
<0.1
≤2
<0.5
<10
7-8.5
<10
<700
<60
<0.1
<0.1
≤2
<0.5
<10
7-8.5
≤0.02 mmol/L
≤15
≤0.2
≤0.1
≤0.1
≤1
≤0.5
≤0.5
5-7.5
2 5
AutoCAD SHX Text
PLUMBING CONNECTIONS & UTILITIES
AutoCAD SHX Text
WATER QUALITY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
REV
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
SHEET #:
AutoCAD SHX Text
REVISION LEVEL:
AutoCAD SHX Text
DRAWING NUMBER:
AutoCAD SHX Text
ANTONIO N.
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text N/A
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text A
AutoCAD SHX Text
SIZE
AutoCAD SHX Text P1
AutoCAD SHX Text A
AutoCAD SHX Text
ADJUST WALL OPENING DIM/CHANGE TRANSFORMER WIRE GA.
AutoCAD SHX Text
AN
AutoCAD SHX Text 7/27/18
AutoCAD SHX Text
9428-023 FM
AutoCAD SHX Text CART WASHER, MODEL 9128E STEAM HEATED, FLOOR MOUNTED. (PLUMBING) ROUGH-IN DRAWING
AutoCAD SHX Text B
AutoCAD SHX Text
UPDATE EXHAUST DESIGN.
AutoCAD SHX Text
AN
AutoCAD SHX Text 4/30/20
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
2021 UPDATES
AutoCAD SHX Text
TDL
LOAD END
(RH)
LOAD END
(LH)
E
6"
M in
. S er vi ce
F al lb ac k [9
.4
M M
STANDARD ELECTRICAL TRANSFORMER
FOR STEAM HEATED UNIT. LOCATED
INSIDE OR OUTSIDE OF SERVICE AREA.
Mass: 198.5 lbs
NOTES:
1) IT SHALL BE THE CUSTOMERS RESPONSIBILITY TO COMPLETE ALL ELECTRICAL
CONNECTIONS USING PROPERLY SIZED WIRING IN ACCORDANCE WITH THE NATIONAL
ELECTRICAL CODE.
2) IT SHALL BE THE CUSTOMERS RESPONSIBILITY TO PROVIDE A FUSED DISCONNECT
SWITCH IN ALL ELECTRICAL SUPPLY LINES AT THE WASHER LOCATION.
3) THE IT-NETWORK SHALL SUPPORT ETHERNET COMMUNICATIONS ON A CONNECTION
AT 100 MBIT/S, HALF-DUPLEX. IT SHALL SUPPORT STANDARD DHCP AND IP ADDRESSING
TECHNOLOGIES. THE NETWORK SHALL SUPPORT ROUTING AND
FIREWALLING: BLOCKING OF SPECIFIC PORTS AND TRAFFIC.
4) IT SHALL BE THE CUSTOMER'S RESPONSIBILITY TO PROVIDE CONNECTION POINTS AND WIRING
BETWEEN THE TRANSFORMER AND WASHER, IF THE PROVIDED CABLE IS NOT ADEQUATE.
5) PER UTILITY DROP (PAGE S1), INSTALL E1 120V GFCI DUPLEX.
1'-33 4"
[400MM]
4' -5
[1
2M
M
1'-2"
[355MM]
1'
[305MM]
SUPPLY
INPUT E
OUTPUT = ELECTRICAL
= ELECTRICAL E1
E
STEAM HEATED
RECOMMENDED
SERVICE
DISCONNECT SEE
NOTE 2
PRIMARY
TRANSFORMER
FULL LOAD AMPS
SECONDARY
TRANSFORMER
FULL LOAD AMPS
(MACHINE)
120 V 60 Hz 20A N/A N/A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
REV
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
SHEET #:
AutoCAD SHX Text
REVISION LEVEL:
AutoCAD SHX Text
DRAWING NUMBER:
AutoCAD SHX Text
ANTONIO N.
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text N/A
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text A
AutoCAD SHX Text
SIZE
AutoCAD SHX Text E1
AutoCAD SHX Text A
AutoCAD SHX Text
ADJUST WALL OPENING DIM/CHANGE TRANSFORMER WIRE GA.
AutoCAD SHX Text
AN
AutoCAD SHX Text 7/27/18
AutoCAD SHX Text
9428-023 FM
AutoCAD SHX Text CART WASHER, MODEL 9128E STEAM HEATED, FLOOR MOUNTED. (ELECTRIC) ROUGH-IN DRAWING
AutoCAD SHX Text B
AutoCAD SHX Text
UPDATE EXHAUST DESIGN.
AutoCAD SHX Text
AN
AutoCAD SHX Text 4/30/20
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
2021 UPDATES
AutoCAD SHX Text
TDL
GSS67N13 - Getinge Steam Sterilizer
GETINGE Steam Sterilizer Model 67N13, 51", SD-LH, Recessed, Display Above
Construction Rough-In Drawings
Getinge 1777 E Henrietta Rd
Rochester, NY 14623 Dwg. 9615-002, Rev. A
9-1-2020
Image may not represent actual model
Construction Rough In drawings
GETINGE GETINGE
At time of purchase order or for egress, wall opening, foot print and utility rough-in for each piece of equipment
Customer or General contractor per GETINGE
Construction Rough In drawing
Customer’s Engineer of Record/Architect and General Contractor.
Based upon overall construction schedule
In Wall Chair Carriers GETINGE Customer’s specified General contractor
Water, Steam, Condensate and Air supply lines to within 5 running feet of equipment’s connection point. Drain
Customer or Plumbing contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Plumbing contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
Floor Sinks and/or Drains
Customer or Plumbing contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Plumbing contractor
Based upon overall construction schedule
Ball and Gate Valves for all supply lines with threads for easier connections
Customer or Plumbing contractor using Industry approved valves and materials
Customer’s/GC specified Plumbing contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
Water, Steam, condensate and Air connections between equipment and facility supply lines
GETINGE using GETINGE Construction Rough In drawing or customer signed GETINGE
Drawing Package
GETINGE
Except where local code require a state licensed plumber or
Union Area
Electrical Disconnect
Customer or Plumbing contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Electrical contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
All branch circuit wiring and conduit (primary and secondary) external to GETINGE supplied equipment
Customer or electrical contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Electrical contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
Electrical final terminations between Utilization
Equipment Outlet boxes and facility power
Customer or electrical contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Electrical line vents Customer or Mechanical contractor using GETINGE Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Mechanical contractor
While ceilings and walls are open during plumbing/electrical/mechanical installation
All branch duct and gravity line vents
Customer or Mechanical contractor using GETINGE
Construction Rough In drawing or customer signed GETINGE
Drawing Package
Customer’s/GC specified Mechanical contractor
While ceilings and walls are open during
GETINGE if installation purchased per sales agreement
Based upon overall construction schedule
Equipment Installation N/A GETINGE if installation purchased per sales agreement
During equipment installation phase based on project schedule Disposal of shipping containers and packing debris to an on installation site customer provided receptacle
N/A
GETINGE if installation purchased per sales agreement
As required during equipment installation phase based on project schedule
Final Installation Checkout N/A GETINGE if installation purchased
Operation: cycle selection, GETINGE GETINGE Following Equipment of equipment in secured protected area N/A
Customer or customer designated shipping contractor
Based upon overall construction schedule
Disposal of any existing equipment N/A Customer After removal from existing
1. Minimum of thirty (30) working days notification will be required for scheduling installation. Additional costs may be billed if less than 30 days’ notice is given.
2. Installation is performed during the hours of 8 a.m. to 5 p.m. excluding weekends and holidays. Overtime charges will apply after 5:00 p.m. and during weekends/holidays.
3. Removal of asbestos or equipment subject to disposal regulations of federal, state or local governments is not included. Pricing must be obtained through local hazardous waste contractors.
4. Pricing does not provide for union labor.
5. Scope of installation work is based upon timely and uninterrupted access, site conditions and utility availability.
Additional visits due to work stoppage beyond the control of Getinge will be billed directly to the buyer at prevailing rates.
6. Purchaser shall provide a site that is compatible to accept the egress of equipment into building, foot print, wall openings, utility supply lines, immediate access valves and which complies with any applicable requirements of any governmental authority.
7. The equipment ordered will be shipped in large crates and ingress into building requires specific height and width.
This includes the path to the final installation location. Dimensions will be provided upon request.
8. If equipment is stored off site, it is the customer’s responsibility to transport equipment to the installation site.
9. Getinge provides layout drawings based on information and/or facility drawings provided. Getinge provides these drawings for reference only to the contractor and architect. It will be the responsibility of the contractor to verify the dimensions for placement within the building based on the required dimensions provided by Getinge.
10. Wall thickness is indicated on the installation/arrangement drawings. For recessed equipment between one or two walls, please pay close attention to the wall thickness indicated to prevent interference with the equipment installation and operation. Wall thickness for the Getinge equipment is vitally important for proper installation, location, fit and function within the facility.
11. Floor protection to protect facility floors during installation is not provided by Getinge.
12. For the purpose of service, Getinge requires adequate permanent lighting in the enclosed service areas of the
Rev P 9/1/2020
VIEW - SIDE
AutoCAD SHX Text
MACHINE FOOT
AutoCAD SHX Text 2'-3 "12"
AutoCAD SHX Text 2'-3 "12"
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text 6'-6"
AutoCAD SHX Text 6'-6"
AutoCAD SHX Text 2'-8 "14"
AutoCAD SHX Text 2'-8 "14"
AutoCAD SHX Text
ALL DIMENSIONS GIVEN ARE FROM FINISHED SURFACES.
AutoCAD SHX Text
DIMENSIONS ARE FEET-INCHES [MILLIMETERS].
AutoCAD SHX Text
VIEW - PLAN
AutoCAD SHX Text
VIEW - FRONT
AutoCAD SHX Text
SERVICE AREA - RECOMMENDED
AutoCAD SHX Text
SERVICE AREA
AutoCAD SHX Text
CLEARANCE
AutoCAD SHX Text
CONTROL CABINET A = STANDARD LOCATION
AutoCAD SHX Text
SERVICE AREA - MIN.
AutoCAD SHX Text
OUTLET TANK
AutoCAD SHX Text
OPTIONAL INTEGRAL STEAM GENERATOR (E)
AutoCAD SHX Text 2'-10 "34"
AutoCAD SHX Text 2'-10 "34"
AutoCAD SHX Text 1'-6"
AutoCAD SHX Text 1'-6"
AutoCAD SHX Text 8"
AutoCAD SHX Text 8"
AutoCAD SHX Text
DISPLAY PANEL ABOVE
AutoCAD SHX Text
CONTROL CABINET B = OPTIONAL LOCATION
AutoCAD SHX Text MAX FLOOR DEVIATION FLAT WITHIN 1/8" (3mm) UNDER UNIT
AutoCAD SHX Text APPROACH AREA TO BE FLAT WITHIN 1/8" (3mm)
AutoCAD SHX Text 6'-3"
AutoCAD SHX Text 6'-3"
AutoCAD SHX Text
ACCESS TO SERVICE AREA TO BE SUPPLIED BY CUSTOMER
AutoCAD SHX Text
CONTROL SIDE
AutoCAD SHX Text
NON CONTROL SIDE
AutoCAD SHX Text
WALL CONNECTION PROFILE
AutoCAD SHX Text
UNIT SHOWN IS A GSS 67N13
AutoCAD SHX Text VACUUM PUMP STANDARD LOCATION CAN ALSO BE LOCATED REMOTELY UP TO 50' (15m) FROM STERILIZER, ON THE SAME FLOOR OR BELOW.
AutoCAD SHX Text POWER CABINET - STANDARD MOUNTING LOCATION SEE DWG E2, SHT 9, FOR OPTIONAL MOUNTING OPTIONS
AutoCAD SHX Text 1'-11 "12"
AutoCAD SHX Text 1'-11 "12"
AutoCAD SHX Text
CONTROL SIDE
AutoCAD SHX Text
CUSTOM TRIM IS AN OPTION
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text HEATING OPTIONS: A = HOUSE STEAM E = ELECTRIC - INTEGRAL ELECTRIC STEAM GENERATOR D = INTEGRAL STEAM TO STEAM GENERATOR
AutoCAD SHX Text NOTES: S1) CLEARANCE SHOWN ARE MINIMAL FOR EQUIPMENT FUNCTION AND SERVICING. CHECK STATE AND LOCAL CODES FOR APPLICABLE CLEARANCE REQUIREMENTS.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SHEET #:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DJL
AutoCAD SHX Text 4/16/19
AutoCAD SHX Text
NONE
AutoCAD SHX Text
AutoCAD SHX Text
REV
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 9615-002
AutoCAD SHX Text
DRAWING NUMBER / FILE NAME:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
XX
AutoCAD SHX Text S1
MODEL 67N13 STEAM STERILIZER, SINGLE DOOR, LEFT SERVICE, RECESSED THROUGH WALL, 51" CHAMBER, DISPLAY ABOVE CHAMBER, ROUGH-IN DRAWING (STRUCTURAL)
%%uNOTICE: Work by others
AutoCAD SHX Text herein as well as any other normally accepted electrical, mechanical or plumbling interface between user's supply
AutoCAD SHX Text Safe and efficient operation of this product is dependent upon the owner/user providing the services specified
AutoCAD SHX Text and this product. Getinge USA will not assume responsibility for problems that result from non-compliance with
AutoCAD SHX Text the above conditions. The following conditions and services are required by Getinge USA equipment and are to be
AutoCAD SHX Text provided by others.
AutoCAD SHX Text 26x24x51
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 2.7
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3.6
AutoCAD SHX Text 0:32
AutoCAD SHX Text 0:49
AutoCAD SHX Text
MINIMUM CLEARANCE REQUIRED FOR MOVING INTO POSITION:
AutoCAD SHX Text
DISMANTLED:35.43"W X 66.14"H X 52.36"L [900W X 1680H X 1630L].
AutoCAD SHX Text 39.37"W X 85.83"H X 64.17"L + 7.87" [1000W X 2180H X 1630L + 200].
AutoCAD SHX Text
(HEIGHT INCLUDES 5.91" [150MM] BOTTOM OF PACKING)
AutoCAD SHX Text
CONTROL PANEL OPTIONS: : A = CONTROL END B = REMOTE END
AutoCAD SHX Text
POWER CABINET OPTIONS: SEE DRAWING E2, ON SHT 9
AutoCAD SHX Text HEATING OPTIONS: A = HOUSE STEAM E = ELECTRIC - INTEGRAL ELECTRIC STEAM GENERATOR D = INTEGRAL STEAM TO STEAM GENERATOR
AutoCAD SHX Text TOTAL HEAT DISSIPATED FROM STERILIZER WITH EMPTY CHAMBER AND 2 DOORS BOTH CLOSED AT AN AMBIENT TEMP OF 23° C (73° F) +/- 2° C (36° F). HEAT DISSIPATED AT THE FRONT IS 2218 BTU/SIDEWITH CLOSED DOOR AND 5937 BTU/SIDE WITH OPEN DOOR.
AutoCAD SHX Text
PERFORMANCE AND DIMENSIONS
AutoCAD SHX Text Process Time, metal load
AutoCAD SHX Text Usable Space (WxHxL) Inside Chamber
AutoCAD SHX Text Loading Capacity
AutoCAD SHX Text Sterilizer Weight
AutoCAD SHX Text Sound Power Level LwA
AutoCAD SHX Text Sound Pressure Level LpA
AutoCAD SHX Text Heat Generation
AutoCAD SHX Text (h:mm)
AutoCAD SHX Text (mm)
AutoCAD SHX Text Instrument trays
AutoCAD SHX Text (kg)
AutoCAD SHX Text (lbs)
AutoCAD SHX Text (dBA)
AutoCAD SHX Text (dBA)
AutoCAD SHX Text (kW)
AutoCAD SHX Text (kg)
AutoCAD SHX Text (lbs)
AutoCAD SHX Text 660x610x1000
AutoCAD SHX Text
AutoCAD SHX Text <70
AutoCAD SHX Text Heat Generation
AutoCAD SHX Text (kW)
AutoCAD SHX Text OPTION: INTEGRAL ELECTRICAL STEAM GENERATOR (E) OPTION: INTEGRAL STEAM TO STEAM GENERATOR (D)
AutoCAD SHX Text Sterilizer weight
AutoCAD SHX Text Comments
AutoCAD SHX Text Prevac 1, 135 C including 16 min vacuum drying.
AutoCAD SHX Text 25 lbs (11.3 kg) per tray
AutoCAD SHX Text Packaging not included
AutoCAD SHX Text SS-EN 285:2006+A2:2009 and ISO 3746:2010
AutoCAD SHX Text Heat dissipated to the surrounding
AutoCAD SHX Text Packaging not included
AutoCAD SHX Text
EMPTY
AutoCAD SHX Text
FULL
AutoCAD SHX Text (Btu/hr)
AutoCAD SHX Text
AutoCAD SHX Text 11270
AutoCAD SHX Text (inch)
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SHEET #:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DJL
AutoCAD SHX Text 4/16/19
AutoCAD SHX Text
NONE
AutoCAD SHX Text
AutoCAD SHX Text
REV
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 9615-002
AutoCAD SHX Text
DRAWING NUMBER / FILE NAME:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
XX
AutoCAD SHX Text S2
MODEL 67N13 STEAM STERILIZER, SINGLE DOOR, LEFT SERVICE, RECESSED THROUGH WALL, 51" CHAMBER, DISPLAY ABOVE CHAMBER, ROUGH-IN DRAWING (STRUCTURAL)
= CENTER OF GRAVITY
AutoCAD SHX Text
A MODEL VIEW - SIDE
AutoCAD SHX Text
A MODEL VIEW - FRONT
AutoCAD SHX Text
CONTROL SIDE
AutoCAD SHX Text
NON CONTROL SIDE
AutoCAD SHX Text
ALL DIMENSIONS GIVEN ARE FROM FINISHED SURFACES.
AutoCAD SHX Text
DIMENSIONS ARE FEET-INCHES [MILLIMETERS].
AutoCAD SHX Text
UNIT SHOWN IS A GSS 67N13
AutoCAD SHX Text
D & E MODEL VIEW - FRONT
AutoCAD SHX Text
D & E MODEL VIEW - SIDE
AutoCAD SHX Text
CONTROL SIDE
AutoCAD SHX Text
NON CONTROL SIDE
AutoCAD SHX Text HEATING OPTIONS: A = HOUSE STEAM E = ELECTRIC - INTEGRAL ELECTRIC STEAM GENERATOR D = INTEGRAL STEAM TO STEAM GENERATOR
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
SHEET #:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DJL
AutoCAD SHX Text 4/16/19
AutoCAD SHX Text
NONE
AutoCAD SHX Text
AutoCAD SHX Text
REV
AutoCAD SHX Text
BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 9615-002
AutoCAD SHX Text
DRAWING NUMBER / FILE NAME:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
XX
AutoCAD SHX Text S3
MODEL 67N13 STEAM STERILIZER, SINGLE DOOR, LEFT SERVICE, RECESSED THROUGH WALL, 51" CHAMBER, DISPLAY ABOVE CHAMBER, ROUGH-IN DRAWING (STRUCTURAL)
D
D
AS
E
CWS
N
S
CW
ASE
FW
FW
N
AutoCAD SHX Text
VIEW - SIDE
AutoCAD SHX Text
VIEW - FRONT
AutoCAD SHX Text HEATING OPTIONS: A = HOUSE STEAM E = ELECTRIC - INTEGRAL ELECTRIC STEAM GENERATOR D = INTEGRAL STEAM TO STEAM GENERATOR
AutoCAD SHX Text 2'-1 "12"
AutoCAD SHX Text 2'-1 "12"
AutoCAD SHX Text 1'-3"
AutoCAD SHX Text 1'-3"
AutoCAD SHX Text 1'-11"
AutoCAD SHX Text 1'-11"
AutoCAD SHX Text 2'-3"
AutoCAD SHX Text 2'-3"
AutoCAD SHX Text 2'-1 "12"
AutoCAD SHX Text 2'-1 "12"
AutoCAD SHX Text 1'-3"
AutoCAD SHX Text 1'-3"
AutoCAD SHX Text 1'-3"
AutoCAD SHX Text 1'-3"
AutoCAD SHX Text 1'-8"
AutoCAD SHX Text 1'-8"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
FINISHED FLOOR
AutoCAD SHX Text
FINISHED WALL
AutoCAD SHX Text
ALL DIMENSIONS GIVEN ARE FROM FINISHED SURFACES.
AutoCAD SHX Text
DIMENSIONS ARE FEET-INCHES [MILLIMETERS].
AutoCAD SHX Text
UNIT SHOWN IS A GSS 67N10
AutoCAD SHX Text
FINISHED FLOOR
AutoCAD SHX Text C
AutoCAD SHX Text L
AutoCAD SHX Text 1'-7"
AutoCAD SHX Text 1'-7"
AutoCAD SHX Text
*SITE UTILITY DROP RECOMMENDATION*
AutoCAD SHX Text
CW = CITY WATER
AutoCAD SHX Text
AS = AIR SUPPLY
AutoCAD SHX Text
S = STEAM (A)
AutoCAD SHX Text
D = PROCESS DRAIN
AutoCAD SHX Text
E = ELECTRICAL (A)
AutoCAD SHX Text
N = NETWORK
AutoCAD SHX Text
UTILITY
A…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .