Attachment C - Drawings.pdf
PDF 10 MB Posted
- Attached to
- Vehicle Access Gates Replacement
- Solicitation number
- S-DASOBO-00017472
- Issued by
- Oregon
About this file
This is an Attachment C - Drawings document for a state and local contract opportunity involving the Oregon Department of Public Safety Standards and Training (DPSST) located in Salem, Oregon. The project involves replacing two existing motorized vehicular entry gates at the main entrance of the DPSST campus at 4190 Aumsville Highway SE. The scope of work includes installation of two new 16-foot-wide swing gates with gate operators, infill fencing to match existing fence style (Ameristar Aegis II Classic or approved equal), and associated electrical work to support gate operation, security systems, and communications. The project also requires removal of existing gates, operators, concrete pads, and related electrical components, along with installation of new equipment including Liftmaster CSW200UL gate operators or approved equivalents, RFID readers (TagMaster XT-5US or approved), induction detection loops for ingress and egress, photo eyes, and integration with the existing Lenel access control system. The architectural firm is Hennebery Eddy Architects, Inc., with electrical engineering by Fluent Engineering.
The construction documents indicate delegated design responsibilities for the contractor regarding engineered drawings and calculations for gate posts and foundations under specification section 32 31 19 for decorative metal fences and gates. The contractor must provide shop drawings and calculations that comply with the 2025 Oregon Structural Specialty Code, 2025 Oregon Fire Code, and 2023 Oregon Electrical Specialty Code, with final designs requiring review and approval by both the architect and authority having jurisdiction. The contractor is responsible for permit acquisition related to delegated design work and must coordinate all equipment verification, utility locations, and system implementations. The project includes a demonstration and adjustment period extending up to four months after substantial completion, with the contractor required to provide RFID tags, programming assistance, system adjustments, and emergency preemption device testing specific to City of Salem and Marion County standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S-DASOBO-00017472-ITB.pdf | ||
| Attachment B-Technical Specs~2.pdf | ||
| S-DASOBO-00017472-Addendum-1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PORTLAND
SALEM
ONTARIO
LA GRANDE
PENDLETON
REDMOND
BEND
KLAMATH FALLS
ASHLAND
MEDFORD
GRANTS PASS
SPRINGFIELDEUGENE
CORVALLIS
THE DALLESCHENOWETH
PRINEVILLE
PROJECT DIRECTORY
ARCHITECT
HENNEBERY EDDY ARCHITECTS, INC
921 SW WASHINGTON STREET, SUITE 250
PORTLAND, OREGON 97205
P: 503.227.4860 F: 503.227.4920
CONTACT:TIM DUDLEY O'NEILL, AIA.
tdudleyoneill@henneberyeddy.com
CLIENT
DEPARTMENT OF PUBLIC SAFETY STANDARDS AND TRAINING
(DPSST)
4190 AUMSVILLE HWY SE
SALEM, OR 97317
P: 503-385-7849
CONTACT: MICHAEL ANDERSON.
michael.anderson@dpsst.oregon.gov
CONTRACTOR
TBD
ELECTRICAL
FLUENT ENGINEERING
2110 STATE ST
SALEM, OR 97301
P: 503.447.5030
CONTACT: MATTHEW CASH, PE.
mcash@fluentengineering.com
MATERIAL HATCHES (CUT)
BREAKLINE
PIPE BREAK
PROPERTY LINE
GRAPHIC LEGEND
EARTH : COMPACTED FILL
CONCRETE
STEEL
BRICK & TILE
CMU
GROUT / MORTAR
EARTH : UNDISTURBED
GRAVEL : CRUSHED
STONE
SYMBOLS
CJ
A301 BUILDING EXTERIOR
ELEVATION
1 REVISION NUMBER
A401 BUILDING SECTION
A501
DETAIL CALLOUT
A501
DETAIL REFERENCE
FIRST FLOOR
100' - 0"
ELEVATION/SECTION
DATUM HEIGHT
DATUM HEIGHT
10' - 0"
CONTROL JOINT
NORTH ARROW
A BUILDING GRID
DESIGNATION
TRUE
NORTH
WORK POINT
A501
PLAN REFERENCE
VIEW NAME
ELEVATION NUMBER
SHEET NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
REVISION AREA
TAG LEGEND
NOT ALL TAGS MAY BE USED
SECTION NUMBER
VIEW NUMBER
SHEET NUMBER
ABBREVIATIONS
ACT
ADA
AFF
CJ
CLR
CMU
CONC
CONT
DEMO
DIA
DIM
DN
DS
(E)
EA
EJ
ELEC
ELEV
EQ
EQUIP
EW
FD
FF
FO
GA
GALV
GYP BD
HR
HSS
HVAC
MAX
MECH
MFR
MIN
N/A
NIC
NO.
NTS
OC
OFCI
OFOI
OPH
P.LAM
PL
PR
PT
RO
SF
SIM
T&G
TG
T.O.
TYP
UON
VIF
W/ W/O
AT
ACOUSTICAL CEILING TILE
AMERICANS WITH DISABILITIES ACT
ABOVE FINISH FLOOR
CONTROL JOINT
CLEAR
CONCRETE MASONRY UNIT
CONCRETE
CONTINUOUS
DEMOLISH/DEMOLITION
DIAMETER
DIMENSION
DOWN
DOWNSPOUT
EXISTING
EACH
EXPANSION JOINT
ELECTRICAL
ELEVATION
EQUAL
EQUIPMENT
EACH WAY
FLOOR DRAIN
FINISH FLOOR
FACE OF
GAUGE
GALVANIZED
GYPSUM BOARD
HOUR
HOLLOW STRUCTURAL SECTION
HEATING, VENTILATING, AIR CONDITIONING
MAXIMUM
MECHANICAL
MANUFACTURER
MINIMUM
NOT APPLICABLE
NOT IN CONTRACT
NUMBER
NOT TO SCALE
ON CENTER
OWNER FURNISHED, CONTRACTOR INSTALLED
OWNER FURNISHED, OWNER INSTALLED
OPPOSITE HAND
PLASTIC LAMINATE
PLATE
PAIR
PRESSURE/PRESERVATIVE TREATED
ROUGH OPENING
SQUARE FEET
SIMILAR
TONGUE AND GROOVE
TEMPERED GLASS
TOP OF
TYPICAL
UNLESS OTHERWISE NOTED
VERIFY IN FIELD
WITH
WITHOUT
FURNISH:
DEFINITIONS
TO SUPPLY, DELIVER, UNLOAD, AND INSPECT FOR DAMAGE.
INSTALL: TO UNPACK, ASSEMBLE, ERECT, APPLY, PLACE, FINISH, CURE,
PROTECT, CLEAN, START UP, AND MAKE READY FOR USE.
PROVIDE: TO FURNISH AND INSTALL.
SUPPLY: SAME AS FURNISH.
Copyright 2026 Hennebery Eddy Architects, Inc.
Sheet:
Date:
HEA Project no.
Drawn by:
Checked by:
COVER
HENNEBERY EDDY ARCHITECTS, INC.
PORTLAND OFFICE
921 SW WASHINGTON ST, SUITE 250
PORTLAND OREGON 97205
503 227 4860 TEL
503 227 4920 FAX
BEND OFFICE
1000 NW WALL ST, SUITE 220
BEND OREGON 97703
541 313 6779 TEL
BOZEMAN OFFICE
109 NORTH ROUSE AVE, SUITE 1
BOZEMAN MONTANA 59715
406 585 1112 TEL
www.henneberyeddy.com
P
\2
-0
D
P S
S T
M a in G a te
\G B
IM
\G
C e n tr a l\2
-0
D
P S
S T M a in
G a te .r vt
/2
/2
:0 :0
P
M
04.27.2026
DPSST Gate Replacement
4190 Aumsville Hwy SE Salem, OR 97317
DPSST
25064-01
TDO
RR
DPSST Gate Replacement
DRAWING SHEET INDEX
GENERAL
COVER COVER
ARCHITECTURAL
A001 SITE PLAN + GENERAL NOTES
A101 SITE - DEMOLITION PLAN
A201 SITE - ENLARGED GATE PLAN
ELECTRICAL
E000 ELECTRICAL COVER SHEET
E100 ELECTRICAL DETAILS
E101 ELECTRICAL DETAILS
E102 ELECTRICAL DETAILS
NOT TO SCALE
VICINITY MAP
NOT TO SCALE
PROJECT LOCATION 4190 AUMSVILLE HWY SE SALEM, OR 97317
OR-22 N. SANTIAM HWY
I-5
K U
E B
L E
R B
L V
D
AU
M
SVILLE H
W
Y SE
TRUE
NORTH
EXISTING ENTRANCE GATE
(E) GUARD
HOUSE
PAVEMENT MARKING
STRIPING AT EGRESS
SURFACE MOUNTED FLEXIBLE
DELINEATOR POSTS, TYP.
EVENLY SPACED
AU
M
SVILLE H
W
Y SE
TERMINATE TRAFFIC STRIPING
AT LINE OF CONCRETE APRON
FOR SITE DEMO PLAN, SEE 1/A101
FOR ENLARGED SITE PLAN, SEE 1/A201
T Y
P A
L L P
O S
T S
' - 0
AREA OF
WORK
AU
M
SVILLE H
W
Y SE
THIS PROJECT INVOLVES REPLACING TWO EXISTING MOTORIZED
VEHICULAR ENTRY GATES AT THE MAIN ENTRANCE OF THE DPSST
CAMPUS.
THE SCOPE INCLUDES INSTALLATION OF TWO NEW SWING GATES WITH
GATE OPERATORS, INFILL FENCING, AND ASSOCIATED ELECTRICAL
WORK TO SUPPORT GATE OPERATION, SECURITY SYSTEMS, AND
COMMUNICATIONS.
GENERAL PROJECT INFORMATION
BUILDING OWNER: OREGON DEPARTMENT OF PUBLIC SAFETY
STANDARDS AND TRAINING (DPSST)
PROJECT ADDRESS: 4190 AUMSVILLE HWY SE
SALEM, OR
RISK CATEGORY: n/a
APPLICABLE CODES
PROJECT DESCRIPTION
CONSTRUCTION TYPE: n/a
2025 OREGON STRUCTURAL SPECIALTY CODE (OSSC)
2025 OREGON FIRE CODE (OFC)
2023 OREGON ELECTRICAL SPECIALTY CODE (OESC)
DELEGATED DESIGN AND DEFERRED SUBMITTALS
1. REFERENCE SPECIFICATION SECTION 01 10 01 - GENERAL DIVISION O
AND DIVISION 1, DELEGATED DESIGN REQUIREMENTS FOR ADDITIONAL
INFORMATION. SEE PROJECT DRAWINGS AND SPECIFICATIONS FOR
BALANCE OF DELEGATED DESIGN COMPONENTS AND SYSTEMS
2. SEE LIST BELOW FOR PORTIONS OF THE PROJECT THAT ARE TO BE
DELEGATED DESIGN AND/OR DEFERRED SUBMITTAL. THE DOCUMENTS
INCLUDED IN THIS PACKAGE ARE PRELIMINARY TO PROVIDE A BASIS FOR
PLANNING AND BIDDING.
3. ACTUAL DRAWINGS, DETAILS, AND CALCULATIONS FOR THE PORTIONS
OF WORK LISTED AS DELEGATED DESIGN/DEFERRED SUBMITTALS ARE
THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL INCLUDE ALL
WORK REQUIRED TO IMPLEMENT THE ENTIRE PROJECT SCOPE RELATED
TO THESE PORTIONS AND COORDINATION WITH OTHER WORK.
4. DELEGATED DESIGN/DEFERRED SUBMITTAL INFORMATION REQUIRES
REVIEW OF BOTH ARCHITECT/ ENGINEER AND APPROVAL BY THE
AUTHORITY HAVING JURISDICTION.
5. PERMIT ACQUISITION FOR THE DELEGATED DESIGN/DEFERRED
SUBMITTAL SCOPE OF WORK SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR.
6. THE CONTRACTOR SHALL VERIFY ALL UTILITIES AND EQUIPMENT, AND
COORDINATE EQUIPMENT REQUIREMENTS AND LOCATIONS.
7. THE PROCEDURE FOR THE CONTRACTOR'S DELEGATED
DESIGN/DEFERRED SUBMITTAL IS AS FOLLOWS:
7.1. INITIAL DESIGN REVIEW SHOP DRAWINGS SHALL BE SUBMITTED
TO THE ARCHITECT FOR PRELIMINARY REVIEW.
7.2. FINAL DESIGN, ENGINEERING, AND SHOP DRAWINGS SHALL BE
SUBMITTED TO THE ARCHITECT FOR REVIEW. SUCH DRAWINGS
SHALL BE STAMPED AND SIGNED BY AN ENGINEER WHEN
REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
7.3. FOLLOWING THE ARCHITECT'S REVIEW, THE CONTRACTOR SHALL
SUBMIT TO THE AUTHORITY HAVING JURISDICTION FOR PERMIT
APPROVAL AND ACQUISITION.
7.4. PROCUREMENT, FABRICATION, AND OTHER WORK RELATED TO
DELEGATED DESIGN SUBMITTAL SHALL NOT BE PERFORMED
UNTIL THE DELEGATED DESIGN DOCUMENTS HAVE BEEN
REVIEWED BY THE ARCHITECT AND THE AUTHORITY HAVING
JURISDICTION.
THE CONTRACTOR IS RESPONSIBLE FOR THE FOLLOWING DELEGATED
DESIGN / DEFERRED SUBMITTALS:
32 31 19 DECORATIVE METAL FENCES AND GATES
PROVIDE ENGINEERED DRAWINGS AND CALCULATIONS FOR GATE
POSTS AND FOUNDATIONS
GENERAL NOTES
1. FOR APPLICABLE CODES AND STANDARDS REFER TO SHEET G01.
2. ALL WORK SHALL COMPLY WITH CODES NOTED ON SHEET G00;
FEDERAL, CITY AND COUNTY ORDINANCES; AND APPLICABLE,
HEALTH, PLUMBING, MECHANICAL, FIRE AND ELECTRICAL CODES.
3. CONFIRM ALL NEW AND EXISTING CONDITIONS WITH THE CONTRACT
DOCUMENTS. NOTIFY ARCHITECT IMMEDIATELY IN WRITING OF ALL
DISCREPANCIES OR CONFLICTS. DO NOT PROCEED WITH WORK IN
THE AREA OF DISCREPANCY OR CONFLICT UNTIL DIRECTION IS GIVEN
BY ARCHITECT. IF CONTRACTOR PROCEEDS WITHOUT DIRECTION
FROM ARCHITECT, IT SHALL BE AT CONTRACTOR'S RISK AND
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED
CORRECTIVE ACTION.
4. REVIEW THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION
OF SYSTEMS SHOWN ON CONSULTING ENGINEER’S DOCUMENTS.
DISCREPANCIES BETWEEN THE ARCHITECTURAL AND CONSULTING
ENGINEER’S DOCUMENTS SHALL BE BROUGHT TO ARCHITECT'S
ATTENTION FOR DIRECTION. CONSTRUCTION INSTALLED IN CONFLICT
WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY
CONTRACTOR AT NO EXPENSE TO THE OWNER.
5. THE CONTRACTOR SHALL ESTABLISH CLEAR UNDERSTANDING OF
REQUIREMENTS OF THE PROJECT, SYSTEMS AND THEIR
COMPONENTS PRIOR TO ORDERING MATERIALS.
6. THE CONTRACTOR SHALL PROVIDE SHORING, BRACING, SUPPORT
AND PROTECTION AS REQUIRED.
7. THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS
OF CONSTRUCTION AND SHALL COORDINATE ALL CONSTRUCTION
EFFORTS WITH THE OWNER'S REQUIREMENTS.
8. THE CONTRACTOR SHALL PROVIDE FOR DUST CONTROL
THROUGHOUT AND SHALL PROVIDE TEMPORARY MEASURES TO
VENTILATE AREAS DURING ALL PHASES OF DEMOLITION AND
CONSTRUCTION, AND SHALL ERADICATE THE BUILD-UP OF FUMES
FROM FINISH MATERIALS AND CONSTRUCTION ACTIVITIES. THE
CONTRACTOR SHALL MAINTAIN SIX (6) AIR EXCHANGES PER HOUR
UNLESS MORE STRINGENT OSHA, STATE OR LOCAL STANDARDS ARE
REQUIRED.
9. THE CONTRACTOR SHALL COORDINATE ALL WORK WITH THE OWNER
AND OWNER PROVIDED CONTRACTORS, IF ANY, AS REQUIRED TO
IMPLEMENT THE SCOPE OF WORK.
10. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR LOCATING,
IDENTIFYING, OR SPECIFYING MEANS OF REMOVAL OF ANY
HAZARDOUS MATERIALS. HAZARDOUS MATERIAL TESTING SHALL BE
COMPLETED BY OWNER CONTRACTED CONSULTANT.
11. IN PERFORMING PROFESSIONAL SERVICES FOR THIS PROJECT,
HENNEBERY EDDY ARCHITECTS, INC. ISSUES, EXPRESSES OR IMPLIES
NO WARRANTIES OR CERTIFICATIONS.
12. COORDINATE FLOOR, WALL AND CEILING FIRE RATINGS WITH CODE
COMPLIANCE SHEETS. ALL PENETRATIONS THROUGH RATED
ASSEMBLIES TO BE SEALED WITH AN APPROPRIATE FIRESTOP SYSTEM
WITH AN EQUAL OR GREATER RATING THAN THE PENETRATED
ASSEMBLY.
13. INFORMATION RELATING TO THE EXISTING BUILDING INCLUDING. BUT
NOT LIMITED, TO SYSTEMS AND CONDITIONS HIDDEN FROM VIEW ARE
BASED ON OWNER PROVIDED DOCUMENTS AND LIMITED FIELD
MEASUREMENTS. ACTUAL CONDITIONS HAVE NOT BEEN VERIFIED BY
THE ARCHITECT AND MAY VARY, INFORMATION PROVIDED FOR
REFERENCE PURPOSES ONLY. SYSTEMS AND CONDITIONS SHALL BE
VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION AND
PROCUREMENT OF MATERIALS OR ITEMS.
14. THE CONTRACTOR SHALL PATCH AND REPAIR ELEMENTS TO MATCH
EXISTING ADJACENT CONDITIONS WHERE ITEMS ARE REMOVED AND
IN AREAS DAMAGED DURING DEMOLITION.
15. THE CONTRACTOR SHALL CLEAN, PLUG, PATCH AND REPAIR ALL
MATERIALS AND SURFACES AS REQUIRED TO PREPARE THEM FOR
NEW WORK.
T H
E A
D
JA
C E
N T
S A
M P
L E
S S
H O
W T
H R
E E
L E
V E
L S
O F
S H
A D
IN
G
S
E T
T
IN
G S
F O
R V
IE
W
IN
G
A N
D P
R
IN
T
IN
G C
O N
TE
N
T A
R E
O P
T
IM
IZ
E
D W
H E
N A
L L
T H
R E
E D
O T
S A
R E
V
IS
IB
L
E
T H
IS
G
U
ID
A N
C E
I S
F O
R R
E F
E R
E N
C E
O N
L Y
B
LA
C
K D
A R
G
A Y
LI
G
H T
A Y
Copyright 2026 Hennebery Eddy Architects, Inc.
Sheet:
Date:
HEA Project no.
Drawn by:
Checked by:
Revisions:
HENNEBERY EDDY ARCHITECTS, INC.
PORTLAND OFFICE
921 SW WASHINGTON ST, SUITE 250
PORTLAND OREGON 97205
503 227 4860 TEL
503 227 4920 FAX
BEND OFFICE
1000 NW WALL ST, SUITE 220
BEND OREGON 97703
541 313 6779 TEL
BOZEMAN OFFICE
109 NORTH ROUSE AVE, SUITE 1
BOZEMAN MONTANA 59715
406 585 1112 TEL
www.henneberyeddy.com
P
\2
-0
D
P S
S T
M a in G a te
\G B
IM
\G
C e n tr a l\2
-0
D
P S
S T M a in
G a te .r vt
/2
/2
:0 :0
P
M
04.27.2026
A001
SITE PLAN +
GENERAL NOTES
DPSST Gate Replacement
4190 Aumsville Hwy SE Salem, OR 97317
DPSST
25064-01
TDO
RR
0' 5' 10' 20' 40' 1" = 20'-0"A001
1 SITE PLAN
TRUE
NORTH
PROJECT
NORTH
1" = 200'-0"A001
2 CAMPUS PLAN
DEMOLITION PLAN NOTES
1. SEE SHEET A001 FOR GENERAL NOTES.
2. COORDINTAE WITH ITEMS NOTED ON ELECTRICAL DEMO SHEET
3. WHERE NOTES IN THE DRAWINGS REQUIRE THE REMOVAL OF A
BUILDING ELEMENT OR SYSTEM OR A COMPLETE COMPONENT
COMPRISED OF MULTIPLE ELEMENTS, THE CONTRACTOR SHALL
DISASSEMBLE AND COMPLETELY REMOVE FROM THE SITE EACH
ITEM IN ITS ENTIRETY SO AS TO ACCOMMODATE THE INSTALLATION
OF THE NEW WORK TO FOLLOW.
4. THE CONTRACTOR SHALL COORDINATE DEMOLITION WITH
EXISTING SYSTEMS SUCH AS STRUCTURAL AND ELECTRICAL
REQUIREMENTS.
5. REMOVE ABANDONED AND ELECTRICAL ITEMS IF THEY WILL BE
VISIBLE AFTER COMPLETION OF THE PROJECT IF UNCOVERED
DURING CONSTRUCTION.
6. EXISTING ELEMENTS NOTED TO REMAIN SHALL BE PROTECTED
DURING CONSTRUCTION. PATCH AND REPAIR AS NECESSARY TO
MAINTAIN EXISTING CONDITION
7. ITEMS TO BE SALVAGED SHALL BE CLEANED AND STORED.
COORDINATE WITH OWNER THE RETURN OF SALVAGED ITEMS.
8. ALL LOCALLY RECYCLABLE MATERIALS REMOVED FROM THE SITE
SHALL BE TRANSPORTED TO THE APPROPRIATE RECYCLER.
DEMOLITION PLAN LEGEND
EXISTNG COMPONENT TO BE REMOVED
EXISTING COMPONENT TO REMAIN
(E) GUARD
HOUSE
(E) PEDESTRIAN GATE TO REMAIN.
REMOVE EXIT BUTTON, STANCHION, AND ELECTRICAL COMPONENTS.
REMOVE (E) GATE OPERATOR AND ALL ASSOCIATED ELECTRICAL COMPONENTS.
CONCRETE PAD TO REMAIN.
REMOVE (E) SWING GATE AND ALL ASSOCIATED HARDWARE
REMOVE (E) GATE OPERATOR AND ALL
ASSOCIATED ELECTRICAL COMPONENTS.
REMOVE (E) CONCRETE PAD.
FILL AND PATCH TO MATCH (E) LANDSCAPE
REMOVE (E) SLIDING GATE AND ALL
ASSOCIATED HARDWARE, STRUCTURAL
SUPPORT, AND OTHER ACCESSORIES.
REMOVE (E) PAVEMENT STRIPING
AND DIRECTIONAL ARROWS AT
EGRESS LANE
(E) PEDESTAL AND TRAFFIC BOLLARD TO REMAIN. SEE ELECTRICAL DEMO PLAN.
SEE ELECTRICAL DRAWINGS FOR ELECTRICAL COMPONENTS TO BE REMOVED.
T H
E A
D
JA
C E
N T
S A
M P
L E
S S
H O
W T
H R
E E
L E
V E
L S
O F
S H
A D
IN
G
S
E T
T
IN
G S
F O
R V
IE
W
IN
G
A N
D P
R
IN
T
IN
G C
O N
TE
N
T A
R E
O P
T
IM
IZ
E
D W
H E
N A
L L
T H
R E
E D
O T
S A
R E
V
IS
IB
L
E
T H
IS
G
U
ID
A N
C E
I S
F O
R R
E F
E R
E N
C E
O N
L Y
B
LA
C
K D
A
A Y
LI
G
A Y
Copyright 2026 Hennebery Eddy Architects, Inc.
Sheet:
Date:
HEA Project no.
Drawn by:
Checked by:
Revisions:
HENNEBERY EDDY ARCHITECTS, INC.
PORTLAND OFFICE
921 SW WASHINGTON ST, SUITE 250
PORTLAND OREGON 97205
503 227 4860 TEL
503 227 4920 FAX
BEND OFFICE
1000 NW WALL ST, SUITE 220
BEND OREGON 97703
541 313 6779 TEL
BOZEMAN OFFICE
109 NORTH ROUSE AVE, SUITE 1
BOZEMAN MONTANA 59715
406 585 1112 TEL
www.henneberyeddy.com
P
\2
-0
D
P S
S T
M a in G a te
\G B
IM
\G
C e n tr a l\2
-0
D
P S
S T M a in
G a te .r vt
/2
/2
:0 :0
P
M
04.27.2026
A101
SITE - DEMOLITION
PLAN
DPSST Gate Replacement
4190 Aumsville Hwy SE Salem, OR 97317
DPSST
25064-01
TDO
RR
0' 2' 4' 8' 16'1/8" = 1'-0"A101
1 SITE - DEMOLITION PLAN
TRUE
NORTH
PROJECT
NORTH
SITE PLAN NOTES
1. SEE SHEET A001 FOR GENERAL NOTES.
2. UNLESS NOTED OTHERWISE, DIMENSIONS ARE TO:
A. FACE OF EXISTING FINISH.
B. FACE OF EXTERIOR FINISH.
A201
PAVEMENT MARKING STRIPING
14' MIN
SURFACE MOUNTED FLEXIBLE DELINEATOR POST, TYP.
MAX.12' SPACING BETWEEN POSTS.
ACCESS CARD READER ON (E) PEDESTAL.
SEE ELECTRICAL.
A201
NEW FENCE, MATCH EXISTING
NEW 16' WIDE SWING GATES. MATCH EXISTING FENCE STYLE.
AMERISTAR AEGIS II CLASSIC OR APPROVED EQUAL
NEW CONCRETE PAD AND GATE OPERATOR.
LIFTMASTER CSW200UL OR APPROVED EQUAL
NEW GATE OPERATOR ON EXISTING CONCRETE PAD.
BASIS OF DESIGN: LIFTMASTER CSW200UL OR APPROVED EQUAL
VERIFY EXISTING PAD LOCATION ALIGNS WITH INSTALLATION
INSTRUCTIONS
A201
Sim
(E) GUARD
HOUSE
INDUCTION DETECTION INTERRUPT LOOP
FOR INGRESS HOLD-OPEN. SEE ELECTRICAL FOR LAYOUT.
INDUCTION DETECTION EXIT AND SHADOW LOOPS
FOR EGRESS ACTIVATION. SEE ELECTRICAL FOR LAYOUT.
INDUCTION DETECTION INTERRUPT LOOP
FOR EGRESS HOLD-OPEN. SEE ELECTRICAL FOR LAYOUT
A201
NEW REQUEST TO EXIT BUTTON AND PEDESTAL IN
SAME LOCATION AS DEMOLISHED.
SEE ELECTRICAL FOR WIRING DETAILS.
(E) GUARD HOUSE ROOF ABOVE
BIKE BUTTON ON NEW PEDESTAL.
SEE ELECTRICAL FOR DETAILS.
16' - 0" +/- V.I.F.
6' - 10" +/-16' - 0"
NEW GATE OPERATOR ON (E) PAD.
VERIFY PAD SIZE AND DIMENSIONS
ALIGN WITH OPERATOR INSTALLATION
NEW 16' WIDE SWING GATES AND INFILL FENCE. MATCH EXISTING FENCE STYLE.
AMERISTAR AEGIS II CLASSIC OR APPROVED EQUAL
M A
T C
H E
X
IS
T
IN
G
V
.I .F
CONCRETE FOOTING FOR GATE POST, TYP
(DELEGATED DESIGN)
M
IN
" 11"
2'-0" MIN
A201
GATE OPERATOR.
COORDINATE DIMENSIONS WITH
INSTALLATION INSTRUCTIONS
NEW CIP CONCRETE PAD
(EXISTING AT SIM)
DIMS FROM FACE OF NEW GATE AND FENCE
COORDINATE WITH GATE INSTALLATION
INSTRUCTIONS.
NEW FENCE AND POST
PAVEMENT MARKING STRIPING.
(EXISTING CURB AT SIM)
M
IN
B E
L O
W F
R O
S T
L
IN
E
METAL GATE OPERATOR ENCLOSURE
CAST IN PLACE CONRETE PAD AND
REINFORCEMENT (DELEGATED DESIGN)
(EXISTING AT SIM)
FINISH GRADE
WALL-MOUNTED RFID READER.
SEE ELECTRICAL FOR DETAILS
MAGNETIC LOCK, MOUNT TO GATE FRAME ON
Z-BRACKET.
MOUNT MAGNETIC PLATE AND JUNCTION BOX
TO (E) WALL
PER MANUFACTURER INSTRUCTIONS.
SEE ELECTRICAL FOR WIRING DETAILS.
SWING GATE
(E) WALL
T H
E A
D
JA
C E
N T
S A
M P
L E
S S
H O
W T
H R
E E
L E
V E
L S
O F
S H
A D
IN
G
S
E T
T
IN
G S
F O
R V
IE
W
IN
G
A N
D P
R
IN
T
IN
G C
O N
TE
N
T A
R E
O P
T
IM
IZ
E
D W
H E
N A
L L
T H
R E
E D
O T
S A
R E
V
IS
IB
L
E
T H
IS
G
U
ID
A N
C E
I S
F O
R R
E F
E R
E N
C E
O N
L Y
B
LA
C
K D
A
A Y
LI
G
A Y
Copyright 2026 Hennebery Eddy Architects, Inc.
Sheet:
Date:
HEA Project no.
Drawn by:
Checked by:
Revisions:
HENNEBERY EDDY ARCHITECTS, INC.
PORTLAND OFFICE
921 SW WASHINGTON ST, SUITE 250
PORTLAND OREGON 97205
503 227 4860 TEL
503 227 4920 FAX
BEND OFFICE
1000 NW WALL ST, SUITE 220
BEND OREGON 97703
541 313 6779 TEL
BOZEMAN OFFICE
109 NORTH ROUSE AVE, SUITE 1
BOZEMAN MONTANA 59715
406 585 1112 TEL
www.henneberyeddy.com
P
\2
-0
D
P S
S T
M a in G a te
\G B
IM
\G
C e n tr a l\2
-0
D
P S
S T M a in
G a te .r vt
/2
/2
:0 :0
P
M
04.27.2026
A201
SITE - ENLARGED
GATE PLAN
DPSST Gate Replacement
4190 Aumsville Hwy SE Salem, OR 97317
DPSST
25064-01
TDO
RR
1/8" = 1'-0"A201
1 SITE - ENLARGED GATE PLAN
0' 2' 4' 8' 16'
TRUE
NORTH
PROJECT
NORTH
1/4" = 1'-0"A201
2 ELEVATION LOOKING SOUTH
1" = 1'-0"A201
4 PLAN DETAIL - EGRESS OPERATOR PAD
1" = 1'-0"A201
5 GATE OPERATOR PAD - SECTION DETAIL
1" = 1'-0"A201
3 PLAN DETAIL - CENTER WALL
AUM
SVILLE HW
Y SE
SHEET NOTES
A. RFID READER DEMONSTRATION, AND SYSTEM ADJUSTMENT PERIOD IS REQUIRED.
CONTRACTOR SHALL PROVIDE NOT LESS THAN THE FOLLOWING UHF TAGS
COMPATIBLE WITH VEHICLE RFID READER (EACH LISTED- TAGMASTER OR APPROVED):
a. (5) VEHICLE WINDSHIELD TAGS
b. (5) VEHICLE HEADLIGHT TAGS
c. (5) ISO CARDS
d. (5) ISO COMBI CARDS
CONTRACTOR SHALL PROVIDE (FURNISH AND INSTALL) ONE RFID READER (XT-5US OR
APPROVE). CONTRACTOR SHALL FURNISH TWO SPARE RFID READERS AS FOLLOWS:
(1) TAGMASTER (OR APPROVED SYSTEM) XT-5US
(1) TAGMASTER (OR APPROVED SYSTEM) LR-6
PLACE RFID READER WHERE SHOWN, INCLUDE PROGRAMMING OF EVERY TAG INDICATED
FOR INGRESS GATE OPENING. PROGRAM EXISTING LENEL ACCESS CONTROL SYSTEM WITH
NEW CARDS/USERS/VEHICLES PER OWNER. SEE UNIT PRICES. PROVIDE 24 HOURS OF
ADDITIONAL PROGRAMMING ASSISTANCE IN BASE BID IN COORDINATION WITH OWNER.
THIS ASSISTANCE IF FOR PROGRAMMING EXISTING USERS, EXACT TIMING OF EQUIPMENT,
ETC. INCLUDE RETURNING NOT LESS THAN 3 ADDITIONAL TIMES, AFTER SUBSTANTIAL
COMPLETION, FOR THE FOLLOWING:
1. ADJUSTING, OR RELOCATING RFID READER AS DIRECTED BY OWNER, OR EOR.
ADJUST SYSTEMS PROGRAMMING. ADJUST LOOP DETECTION SENSITIVITY AS
REQUIRED. GATE OPERATOR SENSITIVITIES/LIMITS, PREEMPTION ADJUSTMENTS
INCLUDING AIM. INCLUDE 6 HOURS ADDITIONAL LABOR.
2. ADJUSTING, AND/OR RELOCATING, AND/OR INSTALLING SPARE RFID READER FOR
NOT LESS THAN TWO READERS AT GATE. ADD ADDITIONAL PROGRAMMING,
CONDUCTORS, ETC. FOR INSTALLING SPARE RFID READER. ADJUST LOOP
DETECTION SENSITIVITY AS REQUIRED. GATE OPERATOR SENSITIVITIES/LIMITS,
PREEMPTION ADJUSTMENTS INCLUDING AIM. . INCLUDE 16 HOURS ADDITIONAL
LABOR, AND ADDITIONAL MATERIAL INDICATED (MATERIAL FOR OPTIONAL
LOCATIONS OF RFID READERS TO BE INCLUDED IN BASE BID). ADJUSTING THE
PROGRAMMING OF THE SYSTEM IS INCLUDED IN THIS PERIOD, AND THUS
INTENDED LABOR HOURS INCLUDES QUALIFIED PROGRAMMER / PROGRAMMING.
3. FINAL ADJUSTMENTS, AND PROGRAMMING TO INSTALLED EQUIPMENT.
DEMONSTRATION PERIOD SHALL EXTEND UP TO 4 MONTHS AFTER SUBSTANTIAL
COMPLETION. BASE BID INCLUDES TAGS, AND ASSOCIATED PROGRAMMING
ONLY. SEE UNIT PRICES. CONTRACTOR IS REQUIRED TO PROVIDE PER, TEST, AND
ADJUST AS WELL AS DEMONSTRATE EMERGENCY PREEMPTION DEVICES SPECIFIC
TO CITY OF SALEM, AND MARION COUNTY EMERGENCY VEHICLE PREEMPTION
STANDARD (SETTINGS). INCLUDE 20 HOURS ADDITIONAL LABOR, AND NOTE THAT
RFID READERS MAY RELOCATE ONCE DURING THIS PART 3 PERIOD AS WELL
(REVERT BACK, OR MOVE TO OTHER IDENTIFIED LOCATION); THUS, INCLUDE
ADDITIONAL MATERIAL (MATERIAL FOR OTHER OPTIONAL RFID READER LOCATION
TO BE INCLUDED IN BASE BID).
LABOR / PROGRAMMING HOURS SHOWN SHALL NOT INCLUDE WARRANTY,
TROUBLESHOOTING, OR BASE SYSTEM OPERATION. THESE HOURS ARE ADDITIONAL, AND
INTENDED FOR SUPPORT USE AT THE OWNER'S DISCRETION.
B. (E) RACEWAY ROUTES ARE ASSUMED, EXACT LOCATION NOT VERIFIED. PROVIDE NEW
RACEWAY AS REQUIRED TO EXECUTE WORK INCLUDING TO CENTER WALL FOR MAG
LOCKS, AND TO GUARD STATION. UNLESS INDICATED NEW RACEWAYS NOT SHOWN.
EXISTING RACEWAYS TO (E) LOOPS NOT SHOWN. (E) SPARE RACEWAY NOT SHOWN.
C. NOT ALL WORK SHOWN ON PLAN VIEW, SEE DETAILS.
D. PROVIDE BOTH LOOP WIRES, AND LOOP DETECTOR INTERFACES WITH ADJUSTABLE
SENSITIVITY. LIFTMASTER LOOPDETLM OR APPROVED. SAW CUT AS REQUIRED TO
PROVIDE. SEE ARCH.
E. MAINTAIN LOOP SEPARATION FROM OTHER LOOPS NOT LESS THAN 4 FEET.
F. PROVIDE RACEWAY AND J-BOX AT EACH PHOTO EYE LOCATION SHOWN. REPLACE
J-BOXES WITH MOUNTING PADS PER DETAILS WHERE PHOTO-EYES INSTALLED. INSTALL
ON SECURE SIDE UNLESS GATE OPERATOR MANUFACTURER ABSOLUTELY REQUIRES ON
UNSECURE SIDE FOR COVERAGE OF ENTRAPMENT ZONE.
G. ONLY VEHICLE DETECTION LOOP WIRES MAY DIFFER IN WIRE SIZE AND INSULATION
TYPE THAN SPECIFICATIONS INDICATE. SEE SPECIFICATIONS FOR OTHER CONDUCTOR
REQUIREMENTS.
1. REMOVE, PROTECT RACEWAY.
2. DISCONNECT (E) LOOPS. NO NOT REMOVE (E) LOOPS UNLESS OTHERWISE INDICATED
BY ARCH. ABANDON. DAMAGE TO (E) LOOP(S) FOR INSTALLATION OF NEW
EXPECTED/OK.
3. THE FOLLOWING WORK IS REQUIRED IN THIS AREA.
3.1. CONNECTION TO (E) ACCESS CONTROL SYSTEM NETWORK FOR REMOTE GATE
OPEN PUSH BUTTON. SEE DETAILS.
3.2. REMOVAL OF (E) INTERCOM/CAMERA.
3.3. PROVIDE SPEAKERS, MICROPHONE AT (E) CAMERA INTERFACE STATION FOR
INGRESS GATE INTERCOM/CALL. SPEAKER & MICROPHONE SHALL BE COMPATIBLE
WITH (E) CAMERA MONITORING STATION/P.C. TEST INTERCOM AUDIBILITY AT EACH
OF 3 LOCATIONS.
3.4. (E) ACCESS CONTROLLER MODIFICATION, ADDITION OF INPUT MODULE (PROVIDE)
TO ACCOMMODATE GATE OPEN BUTTON.
3.5. PROVIDE POWER SUPPLY AND BATTERY BACKUP AS REQUIRED TO ACCOMMODATE
ADDITIONAL EQUIPMENT.
4. SEE DETAILS FOR ADDITIONAL REQUIREMENTS.
5. EXACT LOOP CONFIGURATION PER GATE CONTROLLER REQUIREMENTS. SEE ARCH.
EXTEND EXIT LOOP INTO BOTH NORTH, AND EAST EXITING LANES INTO
INTERSECTION. EXACT LOCATIONS NOT SHOWN. INTERRUPT LOOP SHALL COVER
ENTIRE GATE SWING NAVIGABLE AREA. PROVIDE PER MANUFACTURER'S INSTALLATION
INSTRUCTIONS INCLUDING DEPTH, SEALANT, NUMBER OF TURNS, AND
RECOMMENDED WIRE GAUGE (14,16,18 PER LOOP) WITH XLPE INSULATION. MAINTAIN 4
FEET BETWEEN LOOPS. SEE DETAILS.
6. WITH INTEGRAL BATTERY BACKUP, PHOTO EYE CONTROL, MAG-LOCK CONTROL, LOOP
DETECTION INTERFACE, LOOPS, ETC. AS REQUIRED. SEE ARCH. NOTE PORTIONS OF
GATE OPERATOR INCLUDING THE OPERATOR ITSELF ARE SPECIFIED BY ARCH.
CONTRACTOR RESPONSIBLE FOR A COMPLETE SYSTEM. COORDINATE WITH GENERAL
CONTRACTOR FOR FURNISHING EQUIPMENT INCLUDING GATE OPERATOR
ACCESSORIES WHICH MAY BE SPECIFIED BY EOR.
7. (E) RACEWAYS INCLUDE-POWER, LOOPS, CONTROLS, SPARE (WITHOUT PULLSTRING) (5)
TOTAL. SPARE MAY ONLY EXTEND BEYOND PAD AS A STUB.
8. PROVIDE PEDESTRIAN/BIKE BUTTON. SEE DETAILS. EXACT LOCATION PER OWNER, AND
ARCH.
9. PROVIDE PHOTO EYES. MOUNT BEAM COVERAGE TO PREVENT GATE COLLISION,
AND/OR ENTRAPMENT. LIFTMASTER LMTBUL OR APPROVED. MOUNT ON GATE WALL,
CENTER POSTS, AND AT GROUND AS APPLICABLE. EXACT LOCATIONS NOT SHOWN.
SEE DETAILS, SEE SHEET NOTES.
10. PROVIDE GROUND ROD AT EACH OPERATOR. SEE OPERATOR INSTALLATION
INSTRUCTIONS. SEE DETAILS.
11. SEE UNIT PRICES-- PROVIDE (2) 2"C SPARE. TERMINATE BELOW GRADE IN LANDSCAPE
AREA, AND AT PAD CENTER. CAP EACH END WITH WP CAP. SEE GENERAL NOTES.
12. PROVIDE TWO SETS OF SPEAKERS, AND MICROPHONES AT RECEPTION, COORDINATE
EXACT TYPE WITH OWNER. (i.e. HEAD SET FOR ONE, OR BOTH).
KEYNOTES GENERAL NOTES
1. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
2. DRAWINGS ARE DEVELOPED AS DIGITAL DOCUMENTS. IF CONTRACTOR ELECTS TO PRINT, CONTRACTOR SHALL NOT VIOLATE COPYRIGHT AND DRAWING OWNERSHIP. UTILIZE PROPER SCALE. TEXT SIZE READABILITY IS THE RESPONSIBILITY OF THE CONTRACTOR. IF TEXT IS UNREADABLE ON PRINTED VERSION, CONTACT THE EOR.
DRAWINGS ARE INTENDED TO BE READ WITH DIGITAL ZOOM FUNCTION.
3. HARD-COPY SIGNED AND STAMPED FINAL DOCUMENTS SHALL BE PRINTED AT THE INTENDED SCALE, AND SHALL BE PRINTED SUCH THAT ENGINEER'S SEAL IS LEGIBLE, AND NOT LESS THAN 2-INCHES BY 2-INCHES POINT-TO-POINT PER OAR 820-025-0005. SCALE OF ENGINEER'S SEAL MAY BE DIFFERENT THAN INTENDED DRAWING SCALE. DO NOT RELY UPON ENGINEER'S SEAL SIZE AS ANY INDICATION OF CORRECT DRAWING SCALE, AND/OR PAPER SIZE. DRAWINGS ARE INTENDED AS DIGITAL DOCUMENTS SUCH THAT SEAL SIZE IS
ZOOMABLE TO MEET OAR 820-025-0005.
4. DRAWING DETAIL CALL-OUTS MAY BE PARTIAL. EVERY DETAIL IS APPLICABLE TO THE PROJECT AS A WHOLE
WHERE SUCH DETAILED CONDITION EXISTS.
5. THIS DOCUMENT IS DIGITALLY SIGNED. IF PRINTED, OR “VALID SIGNATURE” BANNER IS NOT DISPLAYED BY THE PDF SOFTWARE, THE PRINTED/DIGITAL COPY IS NO LONGER SIGNED. UNSIGNED DOCUMENTS ARE
PRELIMINARY, AND NOT FOR CONSTRUCTION.
6. SOME EQUIPMENT CONNECTS DIRECTLY TO GATE OPERATORS. MOST OPEN SIGNALS ARE VIA ACCESS
CONTROLLER. SEE CONNECTIONS MATRIX.
7. RACEWAY REQUIRED THROUGHOUT ENTIRE PROJECT.
8. DO NOT EXPOSE ANY RACEWAY/CONDUCTORS AT GATE OPERATORS. GATE OPERATOR FOOTPRINT SHALL
ENTIRELY CONCEAL CONDUCTORS/RACEWAYS.
9. (E) CAMERA SYSTEM MONITORING INTERFACE (P.C., ETC.) IS ASSUMED TO EXIST AT GUARD, AND BUILDING A
RECEPTION. PROVIDE MIC., SPEAKERS, PROGRAMMING AT THOSE LOCATION. SEE KEYNOTES.
10. SEE UNIT PRICES-- PROVIDE (2) 2"C SPARE RACEWAY FROM EACH PAD.
11. PROVIDE LENEL RED COLORED ACCESS CONTROLLER BOARDS. i.e. 1320 SERIES. SEE SPECIFICATIONS.
12. INCLUDE PROGRAMMING OF QUANTITY OF ELEMENTS PROVIDED IN BASE BID FOR RFID CARDS, AND/OR TAGS.
PROGRAMING FOR A COMPLETE OPERABLE SYSTEM SHALL BE INCLUDED IN BASE BID.
POWER
GENERAL
DISCONNECT (F=FUSED, "BLANK"=SWITCH
ONLY)
FLEX CONNECTION
BREAKER
GFI BREAKER
MOTOR
VARIABLE FREQUENCY DRIVE
SURGE PROTECTIVE DEVICE
RELAY
TRANSFORMER
METER
GROUND
JUNCTION BOX
EQUIPMENT TAG (EXHAUST FAN 1 SHOWN)
ELECTRICAL EQUIPMENT AS IDENTIFIED ON
DRAWINGS.
UNDERGROUND/ UNDERFLOOR
RACEWAY
HOMERUN WITH 2 #12
CONDUCTORS
(GROUND NOT SHOWN)
CONCEALED RACEWAY AND
CONDUCTORS. NUMBER OF
SLASHES INDICATES NUMBER OF
CONDUCTORS. PROVIDE GROUND
CONDUCTOR NOT SHOWN. ZERO
SLASHES = 2 CONDUCTORS WITH
3RD GROUND CONDUCTOR.
PROVIDE #12 CONDUCTORS
UNLESS OTHERWISE SHOWN.
#10
HOMERUN WITH 2 #10
CONDUCTORS
(GROUND NOT SHOWN)
HOMERUN WITH 3 #10
CONDUCTORS
(GROUND NOT SHOWN)
KEYNOTE
LOW VOLTAGE CABLE/ HOMERUN
C = CONTROL
C
#10
ELECTRICAL SYMBOL LEGEND
SPECIALTY RECEPTACLE, NEMA SIZE AS NOTED.
DUPLEX RECEPTACLE
POWER PANEL
CALLOUT (SHEET E0.00, DETAIL #1)
KITCHEN EQUIPMENT TAG
X#.##
SPECIFIC RECEPTACLE, SEE PNL SCHED. AND
MECH FOR CONFIGURATION. MATCH
CONFIGURATION PER EQUIPMENT INSTALLED
AFF, A.F.F. ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
ARCH. ARCHITECT/ARCHITECTURAL
BLDG. BUILDING
C CONDUIT
CD CANDELA
CKT CIRCUIT
C.L. COLUMN LINE
(E) EXISTING
ELEC ELECTRICAL
EMERG EMERGENCY
EOR ENGINEER OF RECORD
ESR'S ELECTRICAL SERVICE
REQUIREMENTS
FAM/FACP FIRE ALARM MASTER/FIRE ALARM
CONTROL PANEL
FT. FEET
GFI/B GROUND FAULT
INTERRUPTER/BREAKER
GND, G GROUND
HVAC HEATING, VENTILATION & AIR
CONDITIONING
IDF INTERMEDIATE DISTRIBUTION
FRAME
LV LOW VOLTAGE
MDF MAIN DISTRIBUTION FRAME
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
N.L. NIGHT LIGHT
PNL PANEL
PROVIDE FURNISH AND INSTALL
SD SUB - DISTRIBUTION
TTB TELEPHONE TERMINAL BOARD
TVSS / SPD TRANSIENT VOLTAGE SURGE
SUPPRESSION/SURGE PROTECTION
DEVICE
TYP TYPICAL
WP WEATHER PROOF
" INCH/INCHES
' FOOT/FEET
ABBREVIATIONS
GROUND FAULT, WEATHERPROOF TYPE
FLOOR BOX, FLOOR BOX WITH DATA
REVISION TAG
GFI WP
JJ
M
F
VFD
SWITCH
CONTINUATION
SPD
R
M
G
NORTH ARROW
ADDITIONAL/DETAIL NOTE#
FUSE
VFD
EF
DOUBLE DUPLEX RECEPTACLE
SPLIT WIRED WITH 1/2 SWITCHED, +44 A.F.F
UNO
KEYPLAN (OVERALL SITE PLAN)
SCALE: E0.00
0 200' 400'
DEMOLITION SITE PLAN
SCALE: E0.00
0 16' 32' 64'
ELECTRICAL SITE PLAN
SCALE: E0.00
0 10' 20'
(E) ACCESS CONTROLLER
INTERFACE LOCATION NOT
SHOWN. ROUTE CONCEALED
IN RACEWAY THROUGH
INTERIOR TO NEAREST
ACCESS CONTROL NETWORK
INTERFACE INCLUDE 150-FEET
OF ROUTE IN BASE BID. ROUTE
TO ADMINISTRATION IDF, ON
2ND FLOOR FOR (E) ACCESS
CONTROLLER/INTERFACE
LOCATION.
APPROX LOCATION OF (E)
ADMIN RECEPTION AREA. 3
(E) GATE OPERATOR
CONTROLLER
(E) GATE OPERATOR
CONTROLLER
(E) GATE EDGE
SENSORS (WIRELESS)
TYP. EACH GATE
(E) EMERGENCY
VEHICLE SENSORS
TYP. OF (2).
APPROX. LOCATION OF (E)
PEDESTAL. REMOVE (E)
ACCESS CONTROL CARD
READER/PAD. REMOVE (E)
FLUSH MOUNTED
INTERCOM CALL/CAMERA. SEE DETAILS FOR
WORK IN THIS AREA.
PANEL 0-L1A
J
(E) ACCESS PANEL IN
WALL (FLUSH)
(E) BACK WALL
LOCATION
NOT TO SCALE.
(E) IDF
ACCESS CONTROLLERS
POWER SUPPLIES
(E) PERSON
GATE
PROVIDE WP REQUEST TO EXIT
BUTTON COORDINATE EXACT
REQUIREMENTS WITH ARCHITECT.
(FLUSH, SURFACE, LOCATION, ETC.)
SUBMIT FOR REVIEW.
INGRESS GATE
OPERATOR. 6
J
EGRESS GATE
OPERATOR.6
PROVIDE HAND-HOLE AT (E) GATE
OPERATOR LOCATION. SEE DETAILS.
(E) CENTER POST/WALL SEE DETAILS
FOR WORK IN THIS AREA.
(E) EGRESS PEDESTAL. SEE DETAILS.
INTERRUPT
LOOP5
EXIT
LOOP
SHADOW
LOOP 5
FUTURE RFID J-BOX SEE DETAILS. SEE
DEMONSTRATION REQUIREMENTS.
INTERRUPT
LOOP 5
Color Code
Color
RED
To Indicate
Electric power lines, cables or conduit, and lighting cables
YELLOW Gas, oil, steam, petroleum, or gaseous materials
ORANGE Communication, alarm or signal lines, cables or conduits, and fiber
BLUE
GREEN
WHITE
PINK
PURPLE
Potable water
Sewers, drainage facilities or other drain lines
Pre-marking of the outer limits of the proposed excavation or marking the centerline and width of propose lineal installations of buried facilities
Temporary survey markings
Slurry, irrigation and reclaimed water
FINES MAY BE IMPOSED FOR MISUSE OF COLORS
Adopted by the American Public Works Association.
Underground facilities shall be marked in accordance with the following designated color code (As per OAR 952-001-0070 (8))
S t e w a r d s h ip
T h r o u g h D e s ig n
S
T A T E S
T R
E E T
S A L E M
O
R E G
O N
-4
-5
F l u e n t E n g in e e r in g .c o m
N O
T F
O R
C O
N S
T R
U C
T
IO
N W
H E N
U N
S
IG
N E D
R:
\F lu en t E ng in ee rin g\
Pr oj ec ts
\H en ne be ry E dd y_
D
PS
ST
E nt ra nc e
G at e_
-1
\D ra w in gs \F lu en t 3/
9/
:0 8:
P
M
Copyright 2026 Hennebery Eddy Architects, Inc.
C H
EC
K
SE
T
Sheet:
Date:
HEA Project no.
04.27.2026
DPSST Gate Replacement
4190 Aumsville Hwy SE Salem, OR 97317
DPSST
25064-01
Drawn by: ASM ChecNed by: M-C
Revisions:
HENNEBERY EDDY ARCHITECTS,
INC.
PORTLAND OFFICE
921 SW WASHINGTON ST, SUITE
PORTLAND OREGON 97205
503 227 4860 TEL
503 227 4920 FAX
BEND OFFICE
1000 NW WALL ST, SUITE 220
BEND OREGON 97703
541 313 6779 TEL
BOZEMAN OFFICE
109 NORTH ROUSE AVE, SUITE 1
BOZEMAN MONTANA 59715
406 585 1112 TEL
www.henneberyeddy.com
Permit Set
LEAVE BLANK FOR CITY APPROVAL STAMP
R
EG
IS
TE
RED
PROFESS IONA
L
M
A
T T H EW J . C
A
S
E
N G I N E E
J
N
UARY 1 8 , 2
59,920
OREGON
EXPIRES: 12/31/2027
Matthew J. Cash Digitall\ Signed %\�
E000
ELECTRICAL
COVER SHEET
(4) 1"C t e w a r d s h ip
T h r o u g h D e s ig n
S
T A T E S
T R
E E T
S A L E M
O
R E G
O N
-4
-5
F l u e n t E n g in e e r in g .c o m
N O
T F
O R
C O
N S
T R
U C
T
IO
N W
H E N
U N
S
IG
N E D
R:
\F lu en t E ng in ee rin g\
Pr oj ec ts
\H en ne be ry E dd y_
D
PS
ST
E nt ra nc e
G at e_
-1
\D ra w in gs \F lu en t 3/
9/
:0 8:
P
M
Copyright 2026 Hennebery Eddy Architects, Inc.
C H
EC
K
SE
T
Sheet:
Date:
HEA Project no.
04.27.2026
DPSST Gate Replacement
4190 Aumsville Hwy SE Salem, OR 97317
DPSST
25064-01
Drawn by: ASM ChecNed by: M-C
Revisions:
HENNEBERY EDDY ARCHITECTS,
INC.
PORTLAND OFFICE
921 SW WASHINGTON ST, SUITE
PORTLAND OREGON 97205
503 227 4860 TEL
503 227 4920 FAX
BEND OFFICE
1000 NW WALL ST, SUITE 220
BEND OREGON 97703
541 313 6779 TEL
BOZEMAN OFFICE
109 NORTH ROUSE AVE, SUITE 1
BOZEMAN MONTANA 59715
406 585 1112 TEL
www.henneberyeddy.com
Permit Set
LEAVE BLANK FOR CITY APPROVAL STAMP
R
EG
IS
TE
RED
T T H EW J . C
A
N
UARY 1 8 , 2
EXPIRES: 12/31/2027
Matthew J. Cash Digitall\ Signed %\�
E100
ELECTRICAL
DETAILS
(E) BLDG. A (ADMINISTRATION
BUILDING) MAIN RECEPTION
(SEE KEYPLAN)
DESK MOUNTED (E)
INTERCOM CAMERA.
(E) PERSON GATE
(E) CARD READER
& ELECTRIC STRIKE 2
(E) INGRESS GATE
CONTROLLER
POWER
CONTROLS
POWER
CONTROLS
(E) EMERGENCY
VEHICLE DETECTION
PRE-EMPTION
(OPTICON)
(E) CENTER
POST/WALL
(E) ACCESS CONTROL
CARD READER/KEYPAD
(E) CAMERA/
INTERCOM/BELL1 1
(E) INGRESS
PEDSTAL2
(E) ON-GATE
EDGE SENSOR
(E) LOOP TYP.
DETAIL KEYNOTES:
1. REMOVE. INCLUDING CONDUCTORS. PROVIDE PULL
STRING, OR USE (E) CONDUCTORS IF FEASIBLE FOR NEW
CONDUCTOR PULL(S).
2. PROTECT, REUSE.
3. REMOVE (E) CONNECTIONS FOR GATE, AND PHONE
BUZZ-IN CONNECTION INTERFACE. PROTECT LENEL
UPLINK TO SYSTEM NETWORK. SEE DETAILS - (E) PERSON
GATE ACCESS CONTROL TO REMAIN.
4. REMOVE.
5. DISCONNECT (E) LOOP(S). REMOVE (E) LOOP CONDUCTORS
TO EXTENT FEASIBLE NOT DISTURBING (E) ASPHALT.
(E) POWER
PANEL 0-L1A2
(E) GUARD HOUSE
(E) ACCESS
CONTROLLER
& RADIO
(E) POWER
SUPPLY
DESK MOUNTED
INTERCOM/CAMERA
WALL MOUNTED
GATE OPENER
AND KEY SWITCH.
SCALE: NTS
DEMOLITION SCHEMATIC
E100
SEE PHOTO
(DETAILS) ELEVATION
CALL OUT.
(E) BLDG. A (ADMINISTRATION
BUILDING) MAIN RECEPTION
PROVIDE MICROPHONE/SPEAKERS
INTERFACE AT RECEPTION PC'S TO
INTEGRATE CAMERA, INTERCOM TO (E)
AVIGILON SYSTEM. SUBMIT COMPLETE
PROGRAMMING INTERFACE UPDATE
INCLUDING ADDED HARDWARE.
(TYP. OF 3 LOCATIONS).
(E) PERSON GATE
INGRESS GATE
CONTROLLER
TO ACCESS CONTROLLER
TO (E) POWER PANEL
(E) CENTER
POST/WALL
PROVIDE COMBINATION
ACCESS CONTROL CARD
READER AND KEYPAD.
PROVIDE MOTOROLA AVIGILON INTERCOM
READER BUTTON OP-VID-(E) ENTRY PRO-INT
PEDISTAL OR APPROVED COMPATABLE
WITH (E) AVIGILON. SEE DETAILS.
DETAIL KEYNOTES:
1. PROVIDE NEW ACCESS CONTROLLER AND POWER SUPPLY WITH
BATTERY BACKUP. CONNECT TO (E) LENEL NETWORK (SEE DETAILS).
INCLUDE REQUIRED RFID READER INTERFACE, FUTURE (2) RFID READERS,
GATE OPEN BUTTONS, INPUT MODULES, ETC. SUBMIT COMPLETE
INTERFACE SHOP DRAWINGS SHOWING CONDUCTOR TERMINAL LEVEL
CONNECTIONS. INCLUDE LNL-1100 SERIES INPUT MODULES, LNL-2210
CONTROLLER(S) ETC. SEE DETAILS. PROVIDE COMPLETE PROGRAMMING.
SEE PROGRAMMING INTERFACE MATRIX. CONNECT TO 20/1 IN (E)
PANEL. BATTERY BACKUP SHALL BE SIZED TO POWER DEVICES
CONNECTED SUCH AS RFID, CARD READER, EMERGENCY PRE-EMPTION,
ETC. SUBMIT BATTERY CALCULATIONS. NOT LESS THAN 48-HOURS
STANDBY OPERATION.
2. PROVIDE NEW RACEWAY, INTERFACE TO (E) LOW VOLTAGE ONLY OR
ROUTE COMPLETE TO TERMINATION. PAINT EXPOSED RACEWAY PER
ARCH. DO NOT INTERFACE TO (E) POWER (120V) RACEWAY.
3. EMERGENCY VEHICLE PRE-EMPTION (AUTOMATIC GATE OPEN) TOMAR
2795-3, OR APPROVED.
4. PROVIDE PHOTO EYE. NOT ALL EYES REQUIRED SHOWN. SEE DETAILS,
SEE PLANS.
5. LENEL LNL-XF2110D OR APPROVED COMPATIBLE WITH (E) LENEL SYSTEM.
WP CARD READER AND PIN PAD. MOUNT ON (E) PEDESTAL. SEE DETAILS.
6. MAGNETIC GATE LOCK. CONTROLLED BY GATE CONTROLLER. COORD.
WITH ARCH. FOR MOUNTING CONNECTION.
7. PROVIDE LOOP DROP-OUT RELAY COMPATIBLE WITH LENEL ACCESS
CONTROLLER. DISABLE EXIT LOOP/SHADOW LOOP UPON ACCESS
CONTROLLER LOCKDOWN MODE. SEE PROGRAMMING MATRIX.
(PED/BIKE BUTTON ALSO DISABLES). MOUNT IN GATE CONTROLLER.
8. PROVIDE INGRESS GATE OPEN BUTTON. INCLUDE ANGLED ENCLOSURE,
AND MOMENTARY BUTTON. SIMILAR ENCLOSURE TO HAMMOND
1456FG4WHBU WITH EATON M22-D-R BUTTON. SUBMIT ASSEMBLY.
COORDINATE BUTTON STYLE, AND FINISHES WITH OWNER, AND
ARCHITECT. UNDER DESK MOUNT MAY ALSO BE ACCEPTABLE. FIX
MOUNT TO DESK PER OWNER, WITH MC CABLE BETWEEN BUTTON AND
WALL. EXACT LOCATION PER OWNER.
(E) POWER
PANEL 0-L1A2
(E) GUARD HOUSE
(E) IDF
SCALE: NTS
SCHEMATIC SYSTEM
E100
TO ACCESS
CONTROLLER
TO (E) POWER
PANEL
(E) PANEL
0-L1A
TO ACCESS
CONTROLLER
PROVIDE WP EXIT
BUTTON ON SECURE SIDE
OF FENCE. COORDINATE
EXACT LOCATION.
J
TO ACCESS
CONTROLLER
DETAIL NOTES:
1. REUSE (E) RACEWAY TO EXTENT POSSIBLE.
2. DASHED IS ON SECURE SIDE OF FENCE.
3. SHOP DRAWINGS SHALL INDICATE CONDUCTOR TYPES CONTROL/LV FOR:
AVIGILON INTERFACE, RFID READER, ACCESS CONTROL CARD/KEYPAD, PHOTO
EYES, EMERGENCY VEHICLE PRE-EMPTIONS, GATE OPERATORS/CONTROLLERS,
BIKE/PED BUTTON, PERSON GATE EGRESS BUTTON, ETC.
4. SPARES NOT SHOWN. SEE GROUND NOTES.
R
TO ACCESS CONTROLLER
24 2 4 24
TO EGRESS GATE
CONTROLLER
TO INGRESS GATE
CONTROLLER
PROVIDE EGRESS
INTERRUPT LOOP.
TO ACCESS
CONTROLLER
J
TO ACCESS
CONTROLLER
PROVIDE INGRESS
INTERRUPT LOOP
MOUNT ON
(E) WALL, SEE
DETAILS.2
TO ACCESS
CONTROLLER
PROVIDE POST MOUNTED
PED/BIKE WP EXIT
BUTTON. SEE DETAILS.
NOTE: IT IS NOT ACCEPTABLE TO INTERFACE
DIRECTLY INTO GATE CONTROLLER
UNLESS SPECIFICALLY INDICATED.
OWNER REQUIRED NOTIFICATIONS,
AND OVERRIDE CONTROL THROUGH
(E) LENEL ACCESS CONTROL SYSTEM
FOR CERTAIN FUNCTIONS AS
INDICATED IS REQUIRED.
SCALE: NTS
PANEL SCHEDULE
E100
SCALE: NTS
INTERFACE/CONNECTION MATRIX
E100
SCALE: NTS
PROGRAMMING MATRIX
E100
SCALE: NTS
RFID READER MOUNTING ELEVATION
E1.00
6'-0"
PROVIDE XT-5, TAGMASTER RFID
READER, AND SPARE OR APPROVED.
PROVIDE 1"C RACEWAY FOR
CONNECTION. MOUNT NO LESS THAN
6' AFG. PROVIDE ADJUSTABLE
MOUNTING BRACKET.
3'-6"
PROVIDE J-BOX FOR FUTURE RFID
READER. PROVIDE 1"C RACEWAY
SPARE. MOUNT NO LESS THAN 6' AFG
6'-0"
J
PROVIDE J-BOX FOR FUTURE RFID
READER. PROVIDE 1"C RACEWAY SPARE.
MOUNT NO LESS THAN 3'-6" AFG
DETAIL NOTES:
1. SEE SCHEMATIC FOR CONNECTIONS, AND ADDITIONAL REQUIREMENTS.
2. SEE DEMONSTRATION PERIOD REQUIREMENTS.
J
PROVIDE EGRESS
EXIT LOOP
PROVIDE EGRESS
SHADOW LOOP
TO ACCESS CONTROLLER
TO CAMERA INTERFACE
(SERVER VIA IDF)
(E) INGRESS PEDESTAL
EGRESS GATE
CONTROLLER
e w a r d s h ip
T h r o u g h D e s ig n
S
T A T E S
T R
E E T
S A L E M
O
R E G
O N
-4
-5
F l u e n t E n g in e e r in g .c o m
N O
T F
O R
C O
N S
T R
U C
T
IO
N W
H E N
U N
S
IG
N E D
R:
\F lu en t E ng in ee rin g\
Pr oj ec ts
\H en ne be ry E dd y_
D
PS
ST
E nt ra nc e
G at e_
-1
\D ra w in gs \F lu en t 3/
9/
:0 8:
P
M
Copyright 2026 Hennebery Eddy Architects, Inc.
C H
EC
K
SE
T
Sheet:
Date:
HEA Project no.
04.27.2026
DPSST Gate Replacement
4190 Aumsville Hwy SE Salem, OR 97317
DPSST
25064-01
Drawn by: ASM ChecNed by: M-C
Revisions:
HENNEBERY EDDY ARCHITECTS,
INC.
PORTLAND OFFICE
921 SW WASHINGTON ST, SUITE
PORTLAND OREGON 97205
503 227 4860 TEL
503 227 4920 FAX
BEND OFFICE
1000 NW WALL ST, SUITE 220
BEND OREGON 97703
541 313 6779 TEL
BOZEMAN OFFICE
109 NORTH ROUSE AVE, SUITE 1
BOZEMAN MONTANA 59715
406 585 1112 TEL
www.henneberyeddy.com
Permit Set
LEAVE BLANK FOR CITY APPROVAL STAMP
R
EG
IS
TE
RED
T T H EW J . C
A
N
UARY 1 8 , 2
EXPIRES: 12/31/2027
Matthew J. Cash Digitall\ Signed %\�
SCALE: NTS
GROUND MOUNT - PHOTO EYE
E100
6"
FINISHED GRADE CONFIRM BOLT SIZE, PATTERN,
HEIGHTS & CONDUIT REQUIREMENTS.
PROVIDE FLUSH WITH GRADE MOW STRIP
12"x12"x6" CONC. PAD NTS
3/4" PVC CONDUIT OR
GREATER AS NEEDED.
PHOTO EYE
MOUNTING BRACKET
SCALE: NTS
GROUND ROD DETAIL
E100
GROUND ROD INSTALLATION
GROUND
CONDUCTOR
8"
1" DIA. X 8'-0"
GROUND ROD
COPPER
8" DIA. CONCRETE
PIPE BODYEXOTHERMIC
WELD/GROUND
ROD CLAMP 12"
1" DIA. HOLE
2" THICK CONCRETE COVER OR
GREATER AS REQUIRED FOR
TRAFFIC. TRAFFIC RATED.
SCALE: NTS
PULL BOX HAND HOLE OPEN BUTTON
E100
PROVIDE UTILITY VAULT
COMPANY 233 W/O
BOTTOM OR APPROVED
CONCRETE ENCLOSURE
WITH TRAFFIC RATED
DIAMOND PLATE COVER.
GROUND METALLIC
PORTIONS OF HANDHOLE
PER NEC INCLUDING
COVER.
GALVANIZED DIAMOND PLATE
COVER W/ PADLOCKING LATCH,
TRAFFIC RATED.
BRASS NAME PLATE. LABEL
PER SPECIFICATIONS AND
NEC. INCLUDE "DANGER
HIGH VOLTAGE" WARNING.
PLAN VIEW
BRASS
NAMEPLATE
PROVIDE CORROSION PROOF MESH TO
PREVENT RODENT ENTRY INTO
HANDHOLE. SEE SPECIFICATIONS.
CRUSHED ROCK
AT BASE
FULL 180° OPEN
RECESSED
LIFT HANDLE
COVER NO. 23-2436P
CRUSHED ROCK
2'-8" 3'-8"
3'-6"
3'-0"
6" MIN. ALL SIDES
12"
DETAIL NOTES:
1. PROVIDE CONDUIT EXPANSION FITTINGS AT EXISTING STRUCTURE
EXPANSION JOINTS.
2. ENSURE THE CONCRETE SET BOLT MATERIAL CONFORMS TO ASTM B-633
AND IS MADE OF ZINC PLATED STEEL. ENSURE THE SET BOLT
CHARACTERISTICS CONFORMS TO GSA SPECIFICATION FF S-325, GROUP
VII, TYPE 2.
3. SEE ARCH FOR ADDITIONAL PAINTING REQUIREMENTS GALVANIZED METAL
PRIMER SHALL BE USED.
CONCRETE
WALL
CONCRETE SET BOLTS 3/8"
X 3" OR GREATER AS
REQUIRED (TYP.)
PAINTED GALVANIZED CONDUIT
CLAMP WITH CUSHION, NUT &
BOLT (VIBRATION DAMPING) (TYP.)
PAINTED
CONDUIT
PAINTED GALVANIZED C-CHANNEL
STRUT, 12 GA. (INSTALL SUPPORT
AND CLAMP AT 3' O.C)
PAINTED GALVANIZED C-CHANNEL
STRUT, 12 GA. (INSTALL SUPPORT
AND CLAMP AT 3' O.C)
PAINTED GALVANIZED CONDUIT
CLAMP WITH CUSHION, NUT &
BOLT (VIBRATION DAMPING) (TYP.)
PAINTED
CONDUIT (TYP.)
CONCRETE SET BOLTS 3/8"
X 3" OR GREATER AS
REQUIRED (TYP.)
CONCRETE
WALL
SCALE: NTS
CONCRETE CONDUIT MOUNT DETAIL
E100
SCALE: NTSE100
3 NEW RACEWAY GUARD STATION
PENTRATION
EXTEND CONDUIT (6")
BEYOND WALL WHEN
TERMINATING
MAINTAIN FIRE RATING
PROVIDE FIRE STOP SEAL
AS REQUIRED
WALL/FOUNDATION/ETC.
LINK SEAL OR APPROVED.
INSTALL PER MANUFACTURER'S
REQUIREMENTS.
CORE DRILL HOLE
AS REQUIRED
SCALE: NTS
BIKE/PED EXIT BUTTON
E100
FINISHED GRADE
CONCRETE
1'-0"
DIA.
42"
30"
CURB
DETAIL NOTES:
1. COORDINATE EXACT LOCATION WITH ARCH.
2. COORDINATE PEDESTAL FINISH WITH ARCH.
DETAIL KEYNOTES:
1. PROVIDE WP MOMENTARY PUSH BUTTON WITH
COMPATIBLE STANCHION MOUNTING. BUTTON
SHALL BE MOMENTARY ONLY SUCH THAT IF
HELD (TAPPED) DOWN GATE WILL NOT "HOLD"
OPEN. SEE PROGRAMMING MATRIX.
DO NOT EXTEND
BEYOND CURB LINE
304 STAINLESS STEEL
PEDESTAL PRO 3x3 TUBE
43-3-12-SS, OR APPROVED.
FINISH BY ARCH. SEE PLANS.
E101
ELECTRICAL
DETAILS
SCALE: NTS
(E) GUARD HOUSE - EQUIPMENT
E100
(E) POWER SUPPLY (E) ACCESS
CONTROLLER & RADIO
(E) IDF
(E) POWER PANEL 0-L1A
SCALE: NTS
(E) INGRESS PEDESTAL
E100
REMOVE (E) CALL,
INTERCOM, CAMERA.
(E) ACCESS CONTROL
CARD READER/PIN PAD
NEW EQUIPMENT SHALL BE SECURELY MOUNTED WITHOUT
GAP(S). (E) EQUIPMENT IS FLUSH AND SURFACE MOUNTED.
NEW IS SURFACE OR SEMI-SURFACE MOUNTED.
CONTRACTOR'S OPTION TO REPLACE (E) REMOVABLE PLATE
WITH NEW SAME KEY. LOCKABLE TYPE REMOVABLE PLATE
WITH SAME AS (E) KEY REQUIRED. PROVIDE FIELD FABRICATED
MATCHING METALLIC PATCH PLATE FILLS TO ACCOMMODATE
SMALLER FOOTPRINT SURFACE/SEMI-FLUSH EQUIPMENT FOR
A NEAT AND PROFESSIONAL INSTALLATION. CONTRACTOR'S
OPTION TO SUBMIT FABRICATION DRAWING FOR REVIEW.
e w a r d s h ip
T h r o u g h D e s ig n
S
T A T E S
T R
E E T
S A L E M
O
R E G
O N
-4
-5
F l u e n t E n g in e e r in g .c o m
N O
T F
O R
C O
N S
T R
U C
T
IO
N W
H E N
U N
S
IG
N E D
R:
\F lu en t E ng in ee rin g\
Pr oj ec ts
\H en ne be ry E dd y_
D
PS
ST
E nt ra nc e
G at e_
-1
\D ra w in gs \F lu en t 3/
9/
:0 8:
P
M
Copyright 2026 Hennebery Eddy Architects, Inc.
C H
EC
K
SE
T
Sheet:
Date:
HEA Project no.
04.27.2026
DPSST Gate Replacement
4190 Aumsville Hwy SE Salem, OR 97317
DPSST
25064-01
Drawn by: ASM ChecNed by: M-C
Revisions:
HENNEBERY EDDY ARCHITECTS,
INC.
PORTLAND OFFICE
921 SW WASHINGTON ST, SUITE
PORTLAND OREGON 97205
503 227 4860 TEL
503 227 4920 FAX
BEND OFFICE
1000 NW WALL ST, SUITE 220
BEND OREGON 97703
541 313 6779 TEL
BOZEMAN OFFICE
109 NORTH ROUSE AVE, SUITE 1
BOZEMAN MONTANA 59715
406 585 1112 TEL
www.henneberyeddy.com
Permit Set
LEAVE BLANK FOR CITY APPROVAL STAMP
R
EG
IS
TE
RED
T T H EW J . C
A
N
UARY 1 8 , 2
EXPIRES: 12/31/2027
Matthew J. Cash Digitall\ Signed %\�
SCALE: NTSE102
1 LOOP INSTALLATION REQUIREMENTS
(NOT BY EOR)
SCALE: NTS
PHOTO EYE ENTRAPMENT ZONES (NOT BY EOR)
E102
E102
ELECTRICAL
DETAILS
SCALE: NTS
GENERAL ACCESS CONTROL TOPOLOGY (NOT BY EOR)
E102
NOTE: NOT PROJECT SPECIFIC
THIS N/A TO THIS
PROJECT (NO SIDE WALL)
| Sheets |
| COVER - COVER |
| A001 - SITE PLAN + GENERAL NOTES |
| A101 - SITE - DEMOLITION PLAN |
| A201 - SITE - ENLARGED GATE PLAN |
File details come from the government source that posted it. Updated .