Attachment C_Drawings.pdf
PDF 7 MB Posted
- Solicitation number
- 89503322BWA000004
- Issued by
-
Department of Energy
About this file
This document package includes project drawings and specifications for the Lawrence Livermore Substation Station Service Upgrade federal contract opportunity. Key details include: the solicitation is for the construction and completion of station service upgrades at the Lawrence Livermore Substation in Livermore, California, in accordance with the attached specifications and drawings; the NAICS code is 237130 with a size standard of $36.5 million; this is a 100% small business set-aside acquisition to be awarded as a firm-fixed price contract valued between $250,000 to $500,000; a non-mandatory site visit will be held on May 3, 2022, with an RSVP deadline of April 26; the bid submission deadline is May 6, 2022; all responsible sources may submit a bid; registration in SAM is required to be eligible for award.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 0001.pdf | ||
| Site Visit Sign In Sheet.pdf | ||
| Attachment E-Wage Determinations.pdf | ||
| Attachment D_Submittal Log.pdf | ||
| 1442.pdf | ||
| Attachment B_Specifications.pdf | ||
| Attachment A_Bid Schedule.xls | XLS spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT DRAWINGS
LAWRENCE LIVERMORE SUBSTATION
STATION SERVICE UPGRADES
STATE
SECTION C
DESCRIPTION/SPECIFICATIONS
Spec No. 959
CALIFORNIA
LAWERANCE LIVERMORE SUBSTATION
STATION SERVICE UPGRADES
PROJECT DRAWINGS
A. GENERAL:
CONSTRUCTION DRAWINGS: Construction drawings are the specification drawings and any additional drawings required for use in construction. The construction drawings will be issued after contract award and may include amendment changes and other details, which make the drawings suitable to use for construction purposes.
PROJECT DRAWINGS: Project drawings included herein are reduced reproductions and are not to scale. Some project drawings show details of fabrication and other information not a part of the work. Disregard information and details, which are not applicable.
STANDARD DRAWINGS: Where details shown on standard drawings included herein differ from construction or project drawings or text, the details of construction or project drawings or text shall govern. A complete set of standard drawings are available at https://www.wapa.gov/DoingBusiness/SellingToWestern/Pages/what-western-buys.aspx.
INFORMATIONAL DRAWINGS: Some project drawings have the words “FOR INFORMATION ONLY” appearing above the title block. These drawings show some information, which may be required for bidding purposes. These drawings do not show items to be furnished or work to be performed.
EXISTING INSTALLATION DRAWINGS: Some project drawings have the words “EXISTING INSTALLATION” appearing above the title block. These drawings show the existing installations prior to modifications and may show some new work to be performed.
REFERENCE DRAWINGS: Reference drawings referred to on project drawings and not included herein, are not necessary for bidding purposes.
CONTRACTOR'S RESPONSIBILITY: Check all drawings and advise Western of any errors or omissions.
B. LIST OF DRAWINGS:
LOCATION MAP:
1. LLL 0015 Rev. B – Location, Access Road, & Vicinity
2. TRY 0015 Rev. F – Location, Access Road, & Vicinity
ELECTRICAL:
3. LLL 0001 Rev. B EI – Switching Diagram (Existing Installation)
4. LLL 0001 Rev. D – Switching Diagram
5. LLL 1000 Rev. C EI – Arrangement Plan (Existing Installation)
6. LLL 1000 Rev. D – Arrangement Plan
7. LLL 1100 Rev. B – Equipment and Material Index
8. LLL 1102 – Equipment Identification Signs
9. LLL 1116 Rev. B EI – KY1A Transformer Area Sections P-P and Q-Q (Existing Installation)
10. LLL 1116 Rev. C – KY1A Transformer Area Sections P-P and Q-Q
11. LLL 1511 Rev. C EI – Transformer Area Grounding and Conduit Plan (Existing Installation)
12. LLL 1511 Rev. D - Transformer Area Grounding and Conduit Plan
13. LLL 1610 Rev. B EI – 240/120 Volt Power and Lighting Wiring Diagram (Existing Installation)
14. LLL 1610 Rev. D - 240/120 Volt Power and Lighting Wiring Diagram
15. LLL 1611 Rev. B EI – Transformers KZ1A-KZ2A Wiring Diagram (Existing Installation)
16. LLL 1611 Rev. E - Transformers KZ1A-KZ2A Wiring Diagram
17. LLL 1612 Rev. D – Station Service Panel DZC/DZD Wiring Diagram
CIVIL & SITE DRAWINGS:
18. LLL 2000 Rev. B FIO – Grading and Plot Plan (For Information Only)
FOUNDATION AND STRUCTURAL DRAWING INDEX:
19. LLL 2007 Rev. E – Foundation Designations and Unit Quantities
CONCRETE:
20. LLL 2003 Rev. C EI – Foundation General Plan (Existing Installation)
21. LLL 2003 Rev. D – Foundation General Plan
22. LLL 2004 Rev. B EI – Foundation Plan Transformer Area (Existing Installation)
23. LLL 2004 Rev. C – Foundation Plan Transformer Area
24. LLL 2011 Rev. D – Foundations Outline and Reinforcement
25. LLL 2300 Rev. A – Foundations Outline and Reinforcement
26. LLL 2301 Rev. A – Foundation Outline and Reinforcement
CABLE TRENCH:
27. LLL 2015 Rev. B EI – Type “C” Cable Trench (Existing Installation)
28. LLL 2015 Rev. C – Type “C” Cable Trench
29. LLL 2500 – Cable Trench for Station Service Equipment
STEEL STRUCTURES:
30. LLL 2550 – Anchor Bolts
31. LLL 2600 – Station Service Equipment Support Frame
32. LLL 2601 – Station Service Equipment Support Frame Details
SERVICE BUILDING:
33. LLL 3403 Rev. A – Yard Lighting Circuits and Photocell Yard Lighting Control Wiring Diagram
34. LLL 4000 Rev. I FIO – Service Building Conduit, Arrangement and Grounding (For Information Only) https://www.wapa.gov/DoingBusiness/SellingToWestern/Pages/what-western-buys.aspx https://www.wapa.gov/DoingBusiness/SellingToWestern/Pages/what-western-buys.aspx
LAWERANCE LIVERMORE SUBSTATION
STATION SERVICE UPGRADES
PROJECT DRAWINGS
CONTROLS:
35. LLL T602 – RTU AND CONTROL CABLE LIST
#0
Altamont Pass Rd
Old Patterson Pass Rd TRY-LLL 230 kV
LLL 424 115 kV
§̈¦580
I 580
Greenville Rd
S V as co R d
East Ave
Cross Rd
Las Positas Rd
Lupin Way
Flynn Rd N
Av en ue B
Natio nal Dr
Preston Ave
Southfront Rd
1st St
Scenic Ave
S Portal Dr
Av en ue A
W Pe rim ete r D r
Westgate Dr
Je rro ld Rd
La ug hli n R d
Lawrence Dr
Village Dr
Charlotte Way
So ut hg ate
D r
Th un de rb ird Ln
N Inner Loop
He rm an Av e
5th St
Pullman St
Marathon Dr
Unnamed Street
S Inner Loop
Parking Lot
Patterson Pass Rd
Brisa St
Las Positas Rd
Southfront Rd
Livermore
_̂ Lawrence Livermore Substation Alameda County
0 0.25 0.5 0.75 1 Miles
DECEMBER 19, 1988 LLL
WESTERN AREA POWER ADMINISTRATION
AREA OFFICE - SACRAMENTO, CA
LAWRENCE LIVERMORE SUBSTATION
CALIFORNIA
LOCATION, ACCESS ROAD, & VICINITY
GIS
"S
"S
"S"S
"S
"S
#0
LLL 424 115 kV
TRY-LLL 230 kV
Gr ee nv ille
R d
Old Patterson Pass Rd
N Outer Loop
Patterson Pass Rd
Livermore
Site Coordinates Lat: 37° 41' 36.726" N Long: 121° 41' 43.098" W
DESIGNED _______________________ APPROVED __________________________George T. West Don Warner
UNITED STATES DEPARTMENT OF ENERGY
K #0 Substation "S Structure ! Gate
WAPA Transmission Line Access Road Documented Access Road Public Road ROW Maintenance Road Transmission Line ROW Facility Boundary
Adjoining 7.5' Quadrangle Names Center quad is this site
From: Folsom, CA
1. Merge onto US-50 W 17.8 mi
2. Merge onto I-80BUS W 1.2 mi
3. Turn Right onto I-5/CA-99 N 0.2 mi
4. Take the exit on the Left onto I-5 S toward Los Angeles 59.8 mi
5. Slight Right onto I-205 W 13.7 mi
6. Merge onto I-580 W 7.7 mi
7. Take exit 57 toward N Greenville Rd 0.2 mi
8. Merge onto Altamont Pass Rd 0.1 mi
9. Turn Right onto Greenville Rd (signs for Stockton) 1.8 mi
10. Turn Left onto Patterson Pass Road 0.2 mi Destination will be on the Right To: Livermore Substation 8421 Patterson Rd.
Livermore, CA 94550 104 Miles, 1 hour 39 mins
B 5/13/16 N5 - WAH Revised and Redrawn in GIS
1 2 3
5 6 8 9
1:24,000 1 inch = 2,000 feet
1. Tassajara
2. Byron Hot Springs
3. Clifton Court Forebay
4. Livermore
5. Altamont
6. Midway
7. La Costa Valley
8. Mendenhall Springs
9. Cedar Mtn.
This cartographic product and GIS data were prepared in accordance with professional practice standards. The data represented on this map has been developed from the best available sources. Although efforts have been made to ensure that the data is accurate and reliable, errors may be reflected in the data. Users must be aware of these conditions and bear responsibility for the appropriate use of this map. The data on this map is for reference use only.
court
SUITABLE FOR CONSTRUCTION
kj #0 #0
#0
W Grant Line Rd
Mountain House Rd Mountain House Rd
TCYTSJ 1&2 500 kV
TR
YD
CI
kV
OD
AT
CY
0 k V
HU
RT
RY
1&
2 2 kV
TRYLLL 230 kV
TRYCC 69 kV
TRYLVQ 69 kV
Tracy Maintenace FacilityTracy 69kV
Tracy 230kV Tracy 500kV
W Byron Rd
Un na me d S tre et
Br un s R d
Herdlyn Rd
Christensen Rd
Mo un tai n H ou se
P kw y
Mascot Blvd
Main St
S C en tra l P kw y
Lin de ma n R d
Bethany Ln
Patterson Park Rd
Alley S De Anza Blvd
N Br un s R d
W Questa Trl
Arnaudo Blvd Wi ck lun d R d
W Conejo Ave
Alley
Dr ive wa y
Unnamed Street Dr ive wa y
Tracy
Tracy Maintenance Facility Alameda County
0 0.25 0.5 0.75 1 Miles
December 22, 2015 TRY
WESTERN AREA POWER ADMINISTRATION
SIERRA NEVADA REGION - FOLSOM, CALIFORNIA
TRACY SUBSTATION
CALIFORNIA
LOCATION, ACCESS ROAD, & VICINITY
GIS
#0
#0
#0 kj
Tracy Maintenace FacilityTracy 69kV
Tracy 230kV
Tracy 500kV
Kelso Rd
Mo un tai n H ou se
R d
Tracy
Site Coordinates Lat: 37° 47' 45.913" N Long: 121° 34' 47.596" W
DESIGNED _________________ APPROVED __________________________S. Kullbom Amy S. Fong
UNITED STATES DEPARTMENT OF ENERGY
K
1:30,000 1 inch = 2,500 feet
#0 Substation
#0 Maintenance Facility kj WAPA/SNR Microwave Site "S Structure ! Gate
Western Transmission Lines TANC Transmission Lines Access Road Documented Access Road Public Road ROW Maintenance Road Transmission Line ROW Facility Boundary
Adjoining 7.5' Quadrangle Names Center quad is this site
1. Brentwood
2. Woodward Island
3. Holt
4. Byron Hot Springs
5. Clifton Court Forebay
6. Union Island
7. Altamont
8. Midway
9. Tracy
1 2 3
5 6 8 9
From: Folsom, CA
1. Merge onto US-50 W 17.8 mi
2. Merge onto I-80BUS W 1.2 mi
3. Turn Right onto I-5/CA-99 N 0.2 mi
4. Take the exit on the Left onto I-5 S 59.8 mi
5. Keep Right to continue on I-205 W 7.3 mi
6. I-205 W becomes I-580 W 0.4 mi
7. Take Grant Line Rd exit, Exit 63 0.3 mi
8. Turn Right onto Grant Line Rd 1.2 mi
9. Grant Line Rd turns Right and becomes Byron Rd 4.6 mi
10. Turn Left onto Great Valley Pwky 0.1 mi
11. Take the 1st Right onto Kelso Rd 1.3 mi To: 16800 W. Kelso Road Byron, CA 94514
(209) 833-3040
95.7 Miles, 1 hour 32 mins
This cartographic product and GIS data were prepared in accordance with professional practice standards. The data represented on this map has been developed from the best available sources. Although efforts have been made to ensure that the data is accurate and reliable, errors may be reflected in the data. Users must be aware of these conditions and bear responsibility for the appropriate use of this map. The data on this map is for reference use only.
F 11/23/15 N5 - ASF Revised and Redrawn in GIS
SUITABLE FOR CONSTRUCTION AS OF:
Jan 21, 2022- 9:59am
STATION SERVICE XFMR
KZ1A
13.8KV-240/120V 225KVA
TRANSFORMER KZ1A
AZ1A
SURGE ARRESTER
TRANSFORMER KZ2A
AZ2A
SURGE ARRESTER
STATION SERVICE
SSA
600A 240V
STATION SERVICE
SSB
600A 240V
STATION SERVICE
ATS
600A 240V
STATION SERVICE
DZC
240/120V
STATION SERVICE
DZD
240/120V
STATION SERVICE XFMR
KZ2A
13.8KV-240/120V 225KVA
EMERGENCY GENERATOR
GEN
NORMALLY OPEN
EMERGENCY PANEL TIE
DZC-DZD
NORMALLY OPEN
EMERGENCY PANEL TIE
DZD-DZC
NORMALLY OPEN
EMERGENCY GENERATOR
TRANSFER SEQUENCE INSTRUCTIONS
WARNING
PERSONS NOT FAMILIAR WITH THE OPERATION OF THIS SYSTEM SHALL NOT ATTEMPT TO CHANGE THE POSITION OF ANY OF THESE DEVICES.
FAILURE TO HEED THESE INSTRUCTIONS WILL RESULT IN A LOSS OF POWER AND DAMAGE TO CRITICAL EQUIPMENT.
1. PANEL DZC AND DZD MAIN BREAKERS MUST BE IN THE OPEN POSITION PRIOR TO USING EMERGENCY GENERATOR. DO NOT PARALLEL SOURCES.
6. CLOSE EMERGENCY PANEL TIE BREAKER IN PANEL DZD.
2. OPEN PANEL DZC MAIN BREAKER.
3. CLOSE EMERGENCY PANEL TIE BREAKER IN PANEL DZC.
4. OPEN PANEL DZD MAIN BREAKER.
5. CLOSE EMERGENCY GENERATOR RECEPTACLE BREAKER IN PANEL DZD.
7. CONNECT EMERGENCY GENERATOR TO EMERGENCY GENERATOR RECEPTACLE LOCATED ON PANEL DZD.
LIGHTING
LCU1
CONTACTOR NO. 1
LIGHTING
LCU2
CONTACTOR NO. 2
Jan 21, 2022- 10:01am
Jan 21, 2022- 10:03am
Jan 21, 2022- 10:05am
Feb 11, 2022- 9:01am seela New Stamp
Jan 21, 2022- 10:09am
Jan 21, 2022- 10:11am
Jan 21, 2022- 10:13am
Feb 11, 2022- 1:16pm
Jan 21, 2022- 10:15am
| Cover Page |
| Project Drawings |
| lll_0015b |
| try_0015f |
| lll_0001b_ei |
| lll_0001d |
| lll_1000c_ei |
| lll_1000d |
| lll_1100b |
| lll_1102 |
| lll_1116b_ei |
| lll_1116c |
| lll_1511c_ei |
| lll_1511d |
| lll_1610b_ei |
| lll_1610d |
| lll_1611b_ei |
| lll_1611e |
| lll_1612d |
| lll_2000b_fio |
| lll_2007e |
| lll_2003c_ei |
| lll_2003d |
| lll_2004b_ei |
| lll_2004c |
| lll_2011d |
| lll_2300a |
| lll_2301a |
| lll_2015b_ei |
| lll_2015c |
| lll_2500 |
| lll_2550 |
| lll_2600 |
| lll_2601 |
| lll_3403 |
| lll_4000i_fio |
| lll_t602 |
File details come from the government source that posted it. Updated .