Attachment C_Drawings.pdf

PDF 7 MB Posted

Attached to
Lawrence Livermore Substation Station Service Upgrade
Solicitation number
89503322BWA000004
Issued by

About this file

This document package includes project drawings and specifications for the Lawrence Livermore Substation Station Service Upgrade federal contract opportunity. Key details include: the solicitation is for the construction and completion of station service upgrades at the Lawrence Livermore Substation in Livermore, California, in accordance with the attached specifications and drawings; the NAICS code is 237130 with a size standard of $36.5 million; this is a 100% small business set-aside acquisition to be awarded as a firm-fixed price contract valued between $250,000 to $500,000; a non-mandatory site visit will be held on May 3, 2022, with an RSVP deadline of April 26; the bid submission deadline is May 6, 2022; all responsible sources may submit a bid; registration in SAM is required to be eligible for award.

View the file

Other files

File Type Posted
Amendment 0001.pdf PDF
Site Visit Sign In Sheet.pdf PDF
Attachment E-Wage Determinations.pdf PDF
Attachment D_Submittal Log.pdf PDF
1442.pdf PDF
Attachment B_Specifications.pdf PDF
Attachment A_Bid Schedule.xls XLS spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT DRAWINGS

LAWRENCE LIVERMORE SUBSTATION

STATION SERVICE UPGRADES

STATE

SECTION C

DESCRIPTION/SPECIFICATIONS

Spec No. 959

CALIFORNIA

LAWERANCE LIVERMORE SUBSTATION

STATION SERVICE UPGRADES

PROJECT DRAWINGS

A. GENERAL:

CONSTRUCTION DRAWINGS: Construction drawings are the specification drawings and any additional drawings required for use in construction. The construction drawings will be issued after contract award and may include amendment changes and other details, which make the drawings suitable to use for construction purposes.

PROJECT DRAWINGS: Project drawings included herein are reduced reproductions and are not to scale. Some project drawings show details of fabrication and other information not a part of the work. Disregard information and details, which are not applicable.

STANDARD DRAWINGS: Where details shown on standard drawings included herein differ from construction or project drawings or text, the details of construction or project drawings or text shall govern. A complete set of standard drawings are available at https://www.wapa.gov/DoingBusiness/SellingToWestern/Pages/what-western-buys.aspx.

INFORMATIONAL DRAWINGS: Some project drawings have the words “FOR INFORMATION ONLY” appearing above the title block. These drawings show some information, which may be required for bidding purposes. These drawings do not show items to be furnished or work to be performed.

EXISTING INSTALLATION DRAWINGS: Some project drawings have the words “EXISTING INSTALLATION” appearing above the title block. These drawings show the existing installations prior to modifications and may show some new work to be performed.

REFERENCE DRAWINGS: Reference drawings referred to on project drawings and not included herein, are not necessary for bidding purposes.

CONTRACTOR'S RESPONSIBILITY: Check all drawings and advise Western of any errors or omissions.

B. LIST OF DRAWINGS:

LOCATION MAP:

1. LLL 0015 Rev. B – Location, Access Road, & Vicinity

2. TRY 0015 Rev. F – Location, Access Road, & Vicinity

ELECTRICAL:

3. LLL 0001 Rev. B EI – Switching Diagram (Existing Installation)

4. LLL 0001 Rev. D – Switching Diagram

5. LLL 1000 Rev. C EI – Arrangement Plan (Existing Installation)

6. LLL 1000 Rev. D – Arrangement Plan

7. LLL 1100 Rev. B – Equipment and Material Index

8. LLL 1102 – Equipment Identification Signs

9. LLL 1116 Rev. B EI – KY1A Transformer Area Sections P-P and Q-Q (Existing Installation)

10. LLL 1116 Rev. C – KY1A Transformer Area Sections P-P and Q-Q

11. LLL 1511 Rev. C EI – Transformer Area Grounding and Conduit Plan (Existing Installation)

12. LLL 1511 Rev. D - Transformer Area Grounding and Conduit Plan

13. LLL 1610 Rev. B EI – 240/120 Volt Power and Lighting Wiring Diagram (Existing Installation)

14. LLL 1610 Rev. D - 240/120 Volt Power and Lighting Wiring Diagram

15. LLL 1611 Rev. B EI – Transformers KZ1A-KZ2A Wiring Diagram (Existing Installation)

16. LLL 1611 Rev. E - Transformers KZ1A-KZ2A Wiring Diagram

17. LLL 1612 Rev. D – Station Service Panel DZC/DZD Wiring Diagram

CIVIL & SITE DRAWINGS:

18. LLL 2000 Rev. B FIO – Grading and Plot Plan (For Information Only)

FOUNDATION AND STRUCTURAL DRAWING INDEX:

19. LLL 2007 Rev. E – Foundation Designations and Unit Quantities

CONCRETE:

20. LLL 2003 Rev. C EI – Foundation General Plan (Existing Installation)

21. LLL 2003 Rev. D – Foundation General Plan

22. LLL 2004 Rev. B EI – Foundation Plan Transformer Area (Existing Installation)

23. LLL 2004 Rev. C – Foundation Plan Transformer Area

24. LLL 2011 Rev. D – Foundations Outline and Reinforcement

25. LLL 2300 Rev. A – Foundations Outline and Reinforcement

26. LLL 2301 Rev. A – Foundation Outline and Reinforcement

CABLE TRENCH:

27. LLL 2015 Rev. B EI – Type “C” Cable Trench (Existing Installation)

28. LLL 2015 Rev. C – Type “C” Cable Trench

29. LLL 2500 – Cable Trench for Station Service Equipment

STEEL STRUCTURES:

30. LLL 2550 – Anchor Bolts

31. LLL 2600 – Station Service Equipment Support Frame

32. LLL 2601 – Station Service Equipment Support Frame Details

SERVICE BUILDING:

33. LLL 3403 Rev. A – Yard Lighting Circuits and Photocell Yard Lighting Control Wiring Diagram

34. LLL 4000 Rev. I FIO – Service Building Conduit, Arrangement and Grounding (For Information Only) https://www.wapa.gov/DoingBusiness/SellingToWestern/Pages/what-western-buys.aspx https://www.wapa.gov/DoingBusiness/SellingToWestern/Pages/what-western-buys.aspx

LAWERANCE LIVERMORE SUBSTATION

STATION SERVICE UPGRADES

PROJECT DRAWINGS

CONTROLS:

35. LLL T602 – RTU AND CONTROL CABLE LIST

#0

Altamont Pass Rd

Old Patterson Pass Rd TRY-LLL 230 kV

LLL 424 115 kV

§̈¦580

I 580

Greenville Rd

S V as co R d

East Ave

Cross Rd

Las Positas Rd

Lupin Way

Flynn Rd N

Av en ue B

Natio nal Dr

Preston Ave

Southfront Rd

1st St

Scenic Ave

S Portal Dr

Av en ue A

W Pe rim ete r D r

Westgate Dr

Je rro ld Rd

La ug hli n R d

Lawrence Dr

Village Dr

Charlotte Way

So ut hg ate

D r

Th un de rb ird Ln

N Inner Loop

He rm an Av e

5th St

Pullman St

Marathon Dr

Unnamed Street

S Inner Loop

Parking Lot

Patterson Pass Rd

Brisa St

Las Positas Rd

Southfront Rd

Livermore

_̂ Lawrence Livermore Substation Alameda County

0 0.25 0.5 0.75 1 Miles

DECEMBER 19, 1988 LLL

WESTERN AREA POWER ADMINISTRATION

AREA OFFICE - SACRAMENTO, CA

LAWRENCE LIVERMORE SUBSTATION

CALIFORNIA

LOCATION, ACCESS ROAD, & VICINITY

GIS

"S

"S

"S"S

"S

"S

#0

LLL 424 115 kV

TRY-LLL 230 kV

Gr ee nv ille

R d

Old Patterson Pass Rd

N Outer Loop

Patterson Pass Rd

Livermore

Site Coordinates Lat: 37° 41' 36.726" N Long: 121° 41' 43.098" W

DESIGNED _______________________ APPROVED __________________________George T. West Don Warner

UNITED STATES DEPARTMENT OF ENERGY

K #0 Substation "S Structure ! Gate

WAPA Transmission Line Access Road Documented Access Road Public Road ROW Maintenance Road Transmission Line ROW Facility Boundary

Adjoining 7.5' Quadrangle Names Center quad is this site

From: Folsom, CA

1. Merge onto US-50 W 17.8 mi

2. Merge onto I-80BUS W 1.2 mi

3. Turn Right onto I-5/CA-99 N 0.2 mi

4. Take the exit on the Left onto I-5 S toward Los Angeles 59.8 mi

5. Slight Right onto I-205 W 13.7 mi

6. Merge onto I-580 W 7.7 mi

7. Take exit 57 toward N Greenville Rd 0.2 mi

8. Merge onto Altamont Pass Rd 0.1 mi

9. Turn Right onto Greenville Rd (signs for Stockton) 1.8 mi

10. Turn Left onto Patterson Pass Road 0.2 mi Destination will be on the Right To: Livermore Substation 8421 Patterson Rd.

Livermore, CA 94550 104 Miles, 1 hour 39 mins

B 5/13/16 N5 - WAH Revised and Redrawn in GIS

1 2 3

5 6 8 9

1:24,000 1 inch = 2,000 feet

1. Tassajara

2. Byron Hot Springs

3. Clifton Court Forebay

4. Livermore

5. Altamont

6. Midway

7. La Costa Valley

8. Mendenhall Springs

9. Cedar Mtn.

This cartographic product and GIS data were prepared in accordance with professional practice standards. The data represented on this map has been developed from the best available sources. Although efforts have been made to ensure that the data is accurate and reliable, errors may be reflected in the data. Users must be aware of these conditions and bear responsibility for the appropriate use of this map. The data on this map is for reference use only.

court

SUITABLE FOR CONSTRUCTION

kj #0 #0

#0

W Grant Line Rd

Mountain House Rd Mountain House Rd

TCYTSJ 1&2 500 kV

TR

YD

CI

kV

OD

AT

CY

0 k V

HU

RT

RY

1&

2 2 kV

TRYLLL 230 kV

TRYCC 69 kV

TRYLVQ 69 kV

Tracy Maintenace FacilityTracy 69kV

Tracy 230kV Tracy 500kV

W Byron Rd

Un na me d S tre et

Br un s R d

Herdlyn Rd

Christensen Rd

Mo un tai n H ou se

P kw y

Mascot Blvd

Main St

S C en tra l P kw y

Lin de ma n R d

Bethany Ln

Patterson Park Rd

Alley S De Anza Blvd

N Br un s R d

W Questa Trl

Arnaudo Blvd Wi ck lun d R d

W Conejo Ave

Alley

Dr ive wa y

Unnamed Street Dr ive wa y

Tracy

Tracy Maintenance Facility Alameda County

0 0.25 0.5 0.75 1 Miles

December 22, 2015 TRY

WESTERN AREA POWER ADMINISTRATION

SIERRA NEVADA REGION - FOLSOM, CALIFORNIA

TRACY SUBSTATION

CALIFORNIA

LOCATION, ACCESS ROAD, & VICINITY

GIS

#0

#0

#0 kj

Tracy Maintenace FacilityTracy 69kV

Tracy 230kV

Tracy 500kV

Kelso Rd

Mo un tai n H ou se

R d

Tracy

Site Coordinates Lat: 37° 47' 45.913" N Long: 121° 34' 47.596" W

DESIGNED _________________ APPROVED __________________________S. Kullbom Amy S. Fong

UNITED STATES DEPARTMENT OF ENERGY

K

1:30,000 1 inch = 2,500 feet

#0 Substation

#0 Maintenance Facility kj WAPA/SNR Microwave Site "S Structure ! Gate

Western Transmission Lines TANC Transmission Lines Access Road Documented Access Road Public Road ROW Maintenance Road Transmission Line ROW Facility Boundary

Adjoining 7.5' Quadrangle Names Center quad is this site

1. Brentwood

2. Woodward Island

3. Holt

4. Byron Hot Springs

5. Clifton Court Forebay

6. Union Island

7. Altamont

8. Midway

9. Tracy

1 2 3

5 6 8 9

From: Folsom, CA

1. Merge onto US-50 W 17.8 mi

2. Merge onto I-80BUS W 1.2 mi

3. Turn Right onto I-5/CA-99 N 0.2 mi

4. Take the exit on the Left onto I-5 S 59.8 mi

5. Keep Right to continue on I-205 W 7.3 mi

6. I-205 W becomes I-580 W 0.4 mi

7. Take Grant Line Rd exit, Exit 63 0.3 mi

8. Turn Right onto Grant Line Rd 1.2 mi

9. Grant Line Rd turns Right and becomes Byron Rd 4.6 mi

10. Turn Left onto Great Valley Pwky 0.1 mi

11. Take the 1st Right onto Kelso Rd 1.3 mi To: 16800 W. Kelso Road Byron, CA 94514

(209) 833-3040

95.7 Miles, 1 hour 32 mins

This cartographic product and GIS data were prepared in accordance with professional practice standards. The data represented on this map has been developed from the best available sources. Although efforts have been made to ensure that the data is accurate and reliable, errors may be reflected in the data. Users must be aware of these conditions and bear responsibility for the appropriate use of this map. The data on this map is for reference use only.

F 11/23/15 N5 - ASF Revised and Redrawn in GIS

SUITABLE FOR CONSTRUCTION AS OF:

Jan 21, 2022- 9:59am

STATION SERVICE XFMR

KZ1A

13.8KV-240/120V 225KVA

TRANSFORMER KZ1A

AZ1A

SURGE ARRESTER

TRANSFORMER KZ2A

AZ2A

SURGE ARRESTER

STATION SERVICE

SSA

600A 240V

STATION SERVICE

SSB

600A 240V

STATION SERVICE

ATS

600A 240V

STATION SERVICE

DZC

240/120V

STATION SERVICE

DZD

240/120V

STATION SERVICE XFMR

KZ2A

13.8KV-240/120V 225KVA

EMERGENCY GENERATOR

GEN

NORMALLY OPEN

EMERGENCY PANEL TIE

DZC-DZD

NORMALLY OPEN

EMERGENCY PANEL TIE

DZD-DZC

NORMALLY OPEN

EMERGENCY GENERATOR

TRANSFER SEQUENCE INSTRUCTIONS

WARNING

PERSONS NOT FAMILIAR WITH THE OPERATION OF THIS SYSTEM SHALL NOT ATTEMPT TO CHANGE THE POSITION OF ANY OF THESE DEVICES.

FAILURE TO HEED THESE INSTRUCTIONS WILL RESULT IN A LOSS OF POWER AND DAMAGE TO CRITICAL EQUIPMENT.

1. PANEL DZC AND DZD MAIN BREAKERS MUST BE IN THE OPEN POSITION PRIOR TO USING EMERGENCY GENERATOR. DO NOT PARALLEL SOURCES.

6. CLOSE EMERGENCY PANEL TIE BREAKER IN PANEL DZD.

2. OPEN PANEL DZC MAIN BREAKER.

3. CLOSE EMERGENCY PANEL TIE BREAKER IN PANEL DZC.

4. OPEN PANEL DZD MAIN BREAKER.

5. CLOSE EMERGENCY GENERATOR RECEPTACLE BREAKER IN PANEL DZD.

7. CONNECT EMERGENCY GENERATOR TO EMERGENCY GENERATOR RECEPTACLE LOCATED ON PANEL DZD.

LIGHTING

LCU1

CONTACTOR NO. 1

LIGHTING

LCU2

CONTACTOR NO. 2

Jan 21, 2022- 10:01am

Jan 21, 2022- 10:03am

Jan 21, 2022- 10:05am

Feb 11, 2022- 9:01am seela New Stamp

Jan 21, 2022- 10:09am

Jan 21, 2022- 10:11am

Jan 21, 2022- 10:13am

Feb 11, 2022- 1:16pm

Jan 21, 2022- 10:15am

Cover Page
Project Drawings
lll_0015b
try_0015f
lll_0001b_ei
lll_0001d
lll_1000c_ei
lll_1000d
lll_1100b
lll_1102
lll_1116b_ei
lll_1116c
lll_1511c_ei
lll_1511d
lll_1610b_ei
lll_1610d
lll_1611b_ei
lll_1611e
lll_1612d
lll_2000b_fio
lll_2007e
lll_2003c_ei
lll_2003d
lll_2004b_ei
lll_2004c
lll_2011d
lll_2300a
lll_2301a
lll_2015b_ei
lll_2015c
lll_2500
lll_2550
lll_2600
lll_2601
lll_3403
lll_4000i_fio
lll_t602

File details come from the government source that posted it. Updated .