ATTACHMENT C - Asbestos Testing Results FGWH and FGFC 801 Gales Creek Rd Forest Grove OR.pdf
PDF 392 KB Posted
- Solicitation number
- S-62900-00016548
- Issued by
- Oregon
About this file
This is an asbestos testing results attachment related to the Forest Grove Warehouse & Fire Cache facility located at 801 Gales Creek Road in Forest Grove, Oregon. The document serves as a supporting exhibit for the siding and windows replacement project, providing laboratory analysis and findings regarding the presence or absence of asbestos-containing materials in building components at the facility. The testing results are critical documentation required to inform abatement procedures, safety protocols, and compliance with environmental regulations during the renovation project. These results would guide contractors on appropriate handling procedures and material disposal requirements as they execute the siding and windows replacement work.
The asbestos testing results establish the baseline environmental conditions at the facility and are essential for bid preparation and project planning. Contractors bidding on the siding and windows replacement project must review these findings to accurately estimate labor, materials, and safety measures required for the work. The presence of asbestos-containing materials would necessitate licensed abatement contractors and adherence to federal and state asbestos regulations, potentially affecting project costs, timelines, and scope.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Batch # 2022 * Name / Company *
488801 Oregon Department of Forestry
Analysis Date * Project Name
06/23/2025 FGWH & FGFC
Project # PO #
Analyst * Project Location *
Jason Elbon 801 Gales Creek Rd., Forest Grove, OR
Turnaround Time *
2-Day
Asbestos Analysis of Bulk Material by Polarized Light Microscopy
Sample* Layer
Description* Non Asbestos*
Asbestos Type*
Asbestos
1 1 Window Putty (Tan) - FGWH SW Cellulose None Present N/D
2 1 Window Putty (Tan) - FGWH NW Cellulose None Present N/D
3 1 Window Putty (White / Grey) - FGWH SE Cellulose Chrysotile 2%
4 1 Window Putty (Tan) - FGWH NE Cellulose None Present N/D
5 1 Building Wrap (Black) - FGWH SW Cellulose None Present N/D
6 1 Building Wrap (Brown / Black) - FGWH
NW
Cellulose None Present N/D
7 1 Building Wrap (Black) - FGWH SE Cellulose None Present N/D
8 1 Building Wrap (Black) - FGWH NE Cellulose None Present N/D
1 1 Window Putty (White / Grey) - FGFC NE Cellulose Chrysotile 2%
2 1 Window Putty (White / Grey) - FGFC
NW
Cellulose Chrysotile 2%
2 2 Caulking (White) - FGFC NW Cellulose None Present N/D
3 1 Building Wrap (Black) - FGFC NW Cellulose None Present N/D
4 1 Building Wrap (Black) - FGFC SE Cellulose None Present N/D
5 1 Building Wrap (Black) - FGFC NE Cellulose None Present N/D
To Be Filled by the Technician
Technician *
Atlas Laboratories maintains liability to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full without written permission by Atlas. Atlas bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval or endorsement by NVLAP, NIST, NIOSH or any other agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore Atlas recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Transmission Electron Microscopy asbestos identification and lead paint analysis will be available and performed by laboratories by proxy. Original analysis documents are available upon request of the client.