Attachment_B__Structural_Drawings.pdf
PDF 1006 KB Posted
- Attached to
- Fox Lake Park Boat Ramp Dock Replacement
- Solicitation number
- B-8-26-39
- Issued by
- Brevard County, Florida
About this file
Fox Lake Park Boat Ramp Dock Replacement - Structural Drawings Summary
This attachment contains structural drawings prepared by Adams Engineering Inc. for Brevard County, Florida's Fox Lake Park Boat Ramp Dock Replacement project. The project involves demolition of the existing dock and installation of a new replacement structure at 4400 Fox Lake Road, Titusville, Florida. The structural design is engineered in accordance with the 2023 Florida Building Code and ASCE-7-22 standards, with design criteria including a 60 PSF uniform live load on the deck, 160 MPH wind speed (3-second gust), Risk Category II, and Exposure D. The dock structure measures approximately 243 feet 7½ inches in length with a 24-foot 4½-inch width, featuring a ±3.33% slope and three boat access point openings in the railing. The structural system utilizes pressure-treated Southern Yellow Pine lumber with stainless steel hardware and connections throughout, with all posts set a minimum of 7 feet into existing grade.
The drawings specify construction details for the dock decking, joists, girders, posts, rails, and cap rails, with all structural lumber meeting minimum No. 1 grade for decking, railing, and cap board components and No. 2 grade for girders, joists, and stringers. Materials include 2x6 pressure-treated decking, 2x10 joists at 24-inch on-center spacing, 2x10 girders, 6-inch octagonal posts, 4x4 rail supports, and 2x6 and 2x8 continuous rail components secured with 3/4-inch stainless steel through bolts and #10x3-inch stainless steel deck screws. The contractor must submit a Shipping, Stockpile and Site Administration Plan (SSSAP), Maintenance of Traffic Plan (MOTP), and Site-Specific Safety Plan for approval prior to commencing work, and is responsible for acquiring all necessary building permits, maintaining a clean construction site with designated debris areas, and restoring all facilities and landscaping to original condition following project completion.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Notice_of_Award.pdf | ||
| Bid_Tabulation.pdf | ||
| Bid_Tabulation__Names_Only.pdf | ||
| Bid_Tabulation__Names_Only.pdf | ||
| Addendum_2.pdf | ||
| Fox_Lake_dock_2.jpg | JPG image | |
| SSFOX_LAKE_PARKBid_Set_7826.pdf | ||
| Fox_Lake_dock.jpg | JPG image | |
| Fox_Lake_dock_2.jpg | JPG image | |
| Fox_lake_dock_3.jpg | JPG image | |
| SSFOX_LAKE_PARKBid_Set_7826.pdf | ||
| Addendum_2.pdf | ||
| Fox_lake_dock_3.jpg | JPG image | |
| Fox_Lake_dock.jpg | JPG image | |
| Fox_Lake_dock_4.jpg | JPG image | |
| Fox_lake_dock_5.jpg | JPG image | |
| Fox_Lake_dock_4.jpg | JPG image | |
| Fox_lake_dock_5.jpg | JPG image | |
| Addendum_1.pdf | ||
| Addendum_1.pdf | ||
| Attachment_A__Survey.pdf | ||
| Attachment_A__Survey.pdf | ||
| B82639_INV__SPECS.pdf | ||
| B82639_INV__SPECS.pdf | ||
| Attachment_C__Draft_Contract.pdf | ||
| Attachment_B__Structural_Drawings.pdf | ||
| Attachment_C__Draft_Contract.pdf |
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MATERIAL IDENTIFICATIONS
THE FOLLOWING MATERIAL IDENTIFICATIONS MAY BE USED IN THE STRUCTURAL DRAWINGS:
CONCRETE EARTH GRAVEL GROUT
MASONRY STEEL LT GAGE WOOD
DRAWING INTERPRETATION:
DRAWING VIEWS LABELED AS "TYPICAL":
PARTIAL PLANS, ELEVATIONS, SECTIONS, DETAIL, OR SCHEDULES LABELED WITH "TYPICAL"
BEGINNING OF THIER TITLE APPLY TO SITUATIONS OCCURING ON A PROJECT THAT ARE SAME
OR SIMILAR TO THOSE INDICATED WHETHER OR NOT THEY ARE KEYED AT EACH LOCATION.
APPLICABILITY CAN BE DETERMINED BY THE TITLE OF EACH VIEW.
VIEW REFERENCE SYMBOLS
THE FOLLOWING SYMBOLS MAY BE USED TO REFER TO OTHER VIEWS IN THE DRAWINGS:
ELEVATION SYMBOL
X
SX.X
ELEVATION
NUMBER
SHEET
NUMBER
DETAIL
NUMBER
SHEET
NUMBER
DETAIL SYMBOL
SECTION SYMBOL
SECTION
NUMBER
SHEET
NUMBER
ALL WOOD FRAMING CONSTRUCTION, WORKMANSHIP AND
MATERIALS SHALL CONFORM WITH THE SPECIFICATIONS AND
REQUIREMENTS OF THE REFERENCES LISTED BELOW:
*"AMERICAN INSTITUTE OF TIMBER CONSTRUCTION"
*"NATIONAL DESIGN SPECIFICATION FOR WOOD"
CONSTRUCTION" 2005 AND SUPPLEMENT.
TIMBER
USE CATEGORY
ALL STRUCTURAL LUMBER SHALL BE AS A MINIMUM,
NO.1 GRADE SOUTHERN YELLOW PINE FOR DECKING,
RAILING, CAP BOARD, POSTS, TYP. AND NO.2 SOUTHERN
GRADE YELLOW PINE FOR GIRDERS, JOISTS, STRINGERS,
AND SHALL HAVE AT LEAST THE FOLLOWING MINIMUM
ALLOWABLE DESIGN STRESSES AND MODULUS OF
ELASTICITY AT A MAXIMUM MOISTURE CONTENT OF 19":
1.
2.
Fb (BENDING) Fv (SHEAR) Fc (COMPRESSION) Ft (TENSION) E
1500 PSI
90 PSI
1650 PSI
825 PSI
1,6000,000 PSI
2X4 TIMBER
1250 PSI
90 PSI
1600 PSI
725 PSI
1,6000,000 PSI
2X6 TIMBER
1200 PSI
90 PSI
1550 PSI
650 PSI
1,6000,000 PSI
2X8 TIMBER
Fb (BENDING) Fv (SHEAR) Fc (COMPRESSION) Ft (TENSION) E
1050 PSI
90 PSI
1500 PSI
575 PSI
1,6000,000 PSI
2X10 TIMBER
975 PSI
90 PSI
1450 PSI
550 PSI
1,6000,000 PSI
2X12 TIMBER
ALL LUMBER SHALL BE FACTORY MARKED WITH GRADE
STAMP OF INSPECTION AGENCY, SHOWING COMPLIANCE
WITH GRADING RULE REQUIREMENTS
3.
STAINLESS STEEL HANGERS AND FRAMING ANCHORS SHALL
BE USED AND SHALL BE FASTENED IN ACCORDANCE WITH
THE MANUFACTURERS SPECIFICATIONS
4.
ANCHORING AND NAILING NOT SPECIFIED SHALL COMPLY
WITH THE NAILING SCHEDULE PER THE FBC
5.
USE CATEGORY UC5C MARINE USE SOUTHERN WATERS OF
THE AMERICAN WOOD PROTECTION ASSOCIATION U1-18
6.
PRESERVATIVE RETENTION SPECIFICATIONS (SOLID SAWN MATERIALS, MARINE APPLICATION)
SOUTHERN PINE,
MIXED SOUTHERN PINE
RETENTION SPECIFICATION SOLID SAWN MATERIAL
CR/CR-S ACZA CCA
25 2.5 2.5
ALL FACILITIES, PRIVATE OR PUBLIC, USED FOR ACCESS SHALL BE
REPAIRED TO THEIR ORIGINAL CONDITION FOLLOWING "COMPLETION"
OF THE PROJECT, INCLUDING GRADE AND TOPPING (SOD,
TREE/VEGITATION COVER, ESTABLISHED ROAD, ETC.)
MOBILIZATION AND DEMOBILIZATION
1.
THE CONTRACTOR PRESENT A SHIPPING, STOCKPILE AND SITE
ADMINISTRATION PLAN (SSSAP) TO THE OWNER, OWNER'S
REPRESENTATIVEOR ENGINEER FOR APPROVAL. THE PLAN SHALL BE
SPECIFIC TO THE PROJECT REQUIREMENTS FOR THE PARTICULAR
MATERIALS TO BE DELIVERED TO THE SITE, DESCRIBING DELIVERY
POINTS, STOCKPILE AREAS, TEMPORARILY DEBRIS/TRASH STORAFE
AREAS, TEMPORARY FIELD OFFICE (INCL. UTILITIES MAINTAINED THERE),
FENCING, SECURITY ABD A STATEMENT OF COMMITMENT AND DETAILS
FOR MAINTAINING SAFETY ON THE SITE.
2.
THE OWNER, OWNER'S REP OR ENGINEER SHALL HAVE THE RIGHT TO
EXERCISE REASONABLE ALTERATIONS OR ADDITIONS TO THE SSSAP.
3.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE, AND PAY FOR,
NECESSARY UTILITIES TO OCCUPY THE SITE AND PERFORM THE WORK
4.
THE CONTRACTOR SHALL NOT DEMOBILIZE UNTIL PROJECT COMPLETION5.
THE CONTRACTOR SHALL PROVIDE "ACCESS CLOSED FOR
CONSTRUCTION" SIGNS - "NO TRESPASSING" AND BARACADES OFF OF
THE BEACH ACCESS
6.
THE CONTRACTOR SHALL MAINTAIN A CLEAN AND NEAT SITE, VOID OF
LOOSE DEBRIS, TRASH, REMNANT PARTS OR MATERIALS.
SITE MAINTENANCE
1.
TRASH RECEPTACLES AND REMOVAL SERVICE SHALL BE MAINTAINED BY
THE CONTRACTOR SPECIFICALLY FOR THIS PROJECT. PRE-EXISTING
TRASH/DEBRIS FACILITIES SHALL NOT BE USED TO MAINTAIN THE PROJECT
2.
TEMPORARY DEBRIS PILES SHALL BE LIMITED IN NUMBER AS MUCH AS
PRACTICAL AND CONTAINED IN DESIGNATED AREAS UNTIL REMOVAL.
DEBRIS AND TRASH SHALL NOT BE SCATTERED IN AREAS OUTSIDE THE
LIMITED DESIGNATED AREAS AT ANY TIME.
3.
REMOVAL OF TRASH/DEBRIS SHALL BE SCHEDULED AS APPROPRIATE TO
NOT ALLOW PILES TO REACH FIVE FEET IN HEIGHT OR GREATER THEN TEN
FEET IN DIAMETER. DEBRIS INDIVIDUALLY LARGER THEN THESE
DIMENSIONS SHALL BE REMOVED FROM THE SITE WITHIN FIVE WORKING
DAYS. RECEPTACLES SHALL NOT OVERFLOW AT ANY TIME. CONTAIN AND
PROTECT ALL DEBRIS FROM BECOMING WIND BOURNE.
4.
WHERE NECESSARY, THE CONTRACTOR SHALL EMPLOY A MAINTENANCE
OF TRAFFIC PLAN (MOTP) FOR VEHICLES AND PEDESTRIANS INCLUDING
MATERIAL DELIVERIES, STOCKPILE AREA(S), WORKER PARKING AND
CONSTRUCTION EQUIPMENT. THE PLAN MUST BE IN WRITING, INCLUDING
SKETCHES OR DRAWINGS, AND MUST BE SUBMITTED TO THE OWNER,
OWNER'S REP OR ENGINEER FOR REVIEW AND APPROVAL BEFORE
COMMENCEMENT OF ANY WORK.
5.
THE CONTRACTOR SHALL FOLLOW ALL APPLICABLE LOCAL, STATE AND
FEDERAL CODES REGARDING SITE MAINTENANCE.
6.
THE CONTRACTOR SHALL PREPARE AND ADHERE TO A SITE-SPECIFIC
SAFETY PLAN. THE CONTENTS OF THE PLAN ARE:
1. IDENTIFICATION OF POTENTIAL HAZARDS AND INJURIES PERTAINING
TO THE SPECIFIC SITE AND PROJECT.
2. LOCATION NEAREST HOSPITAL.
3. ASSURE AVAILABILITY OF AT LEAST ONE WORKING CELL PHONE AND
ONE VEHICLE ON SITE AT ALL TIMES.
4. EMERGENCY CONTACTS WITHIN THE SUBCONTRACTORS
ORGANIZATION AND AT THE PRIME CONTRACTORS ORGANIZATION.
5. ALL FIELD PERSONNEL WEAR APPROPRIATE PERSONAL PROTECTION
EQUIPMENT FOR A GIVEN TASK/OPERATION SUCH AS SAFETY
GLASSES/GOGGLES, MASKS, SHIELDS, GLOVES, HARNESSES, HARD
HATS, STEEL-TOED BOOTS, ETC.
6. SAFETY KIT AVAILABLE ONSITE AT ALL TIMES WITH MATERIALS FOR
POTENTIAL HAZARDS AND INJURIES.
7. THE SITE SPECIFIC SAFETY PLAN SHALL BE DISTRIBUTED AND
REVIEWED WITH ALL SITE WORKERS PRIOR TO SAID WORKERS
COMMENCING WORK ON THE PROJECT SITE.
8. THE CONTRACTOR SHALL FOLLOW ALL APPLICABLE LOCAL, STATE
AND FEDERAL CODES REGARDING SITE SAFETY.
SITE SAFETY
LOCATION MAP
DOCK LOCATION
DEMOLITION OR CLEARING MAY REQUIRE PERMITS. THE CONTRACTOR
SHALL ACQUIRE ALL NECESSARY BUILDING PERMITS FROM THE LOCAL
MUNICIPALITY PRIOR TO COMMENCING WORK.
DEMOLITION, CLEARING AND RESTORATION
1.
CLEARING AND REMOVAL OF VEGITATION, ROCKS AND DEBRIS MAY BE
REQUIRED WITHIN THE PROJECT STRUCTURE FOOTPRINT.
2.
DEMOLITION OR REMOVAL OF OBJECTS, DEBRIS, OR MATERIAL
SPECIFIED OR OBSTRUCTING CONSTRUCTION SHALL TAKE PLACE ONLY
TO THE EXISTING EXTENT NECESSARY
3.
ANY PERMITTED DEMOLITION OR REMOVAL FROM SUBMERGED LANDS
OR ADJACENT UPLANDS SHALL BE FULLY CONTAINED WITHIN SILTATION
DEVICES SUCH THAT PERMIT TURBIDITY REQUIREMENTS AND STATE
WATER QUALITY STANDARDS ARE MET.
4.
THE SITE SHALL BE RESTORED BY REMOVING AND FINISHING ALL
EVIDENCE OF CONSTRUCTION INCLUDING TEMPORARILY HAUL ROADS,
VEHICLE RUTS, STOCKPILE AREAS, SHORELINE SLOPES AND
VEGITATION, SOD AND AREAS SUBJECT TO PROJECT WORK.
5.
ALL STRUCTURAL WORK FOR THIS PROJECT HAS BEEN ENGINEERED
IN ACCORDANCE WITH: THE FLORIDA BUILDING CODE, 2023 ASCE-7 22
"MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES.
ALL CONSTRUCTION SHALL COMPLY WITH THE REQUIREMENTS AND
SPECIFICATIONS OF THESE CODES AND THEIR REFERENCED
STANDARDS, AND ALL OTHER APPLICABLE FEDERAL, STATE, AND
LOCAL CODES, STANDARDS, REGULATIONS AND LAWS.
DESIGN CRITERIA
DESIGN GRAVITY LOADS:
LOCATION UNIFORM LIVE LOAD
DECK 60 PSF
DESIGN WIND LOADS:
WIND SPEED: (3 SECOND GUST) V=160 MPH
RISK CATEGORY: CATEGORY II
EXPOSURE: D
T
HOMA S L . A DAM
S
P R
O F
E
S S
I ONA L ENG
I N E
E R
L I CENSE
F L O R I D A
STATE OF
No. 55343
CCOPYRIGHT STATEMENT
THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF
ADAMS ENGINEERING INC. (AEI) AND ARE ISSUED ONLY FOR THE
SPECIFIC PROJECT NOTED ON THESE DOCUMENTS. ANY REVISIONS,
REPRODUCTIONS OR MODIFICATIONS OF THESE DOCUMENTS WITHOUT THE
EXPRESS WRITTEN CONSENT OF AEI IS PROHIBITED BY LAW.
R E
V
D A
T E
R E
V
IS
IO
N
D R
A W
IN
G
T
IT
L E
PROJ. NO. :
SCALE
DATE
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ENGINEER OF RECORD
THOMAS L. ADAMS, PE
PE #55343
A D
A M
S E
N G
IN
E
E R
IN
G
I N
C
C O
N S
U L
T
IN
G S
T R
U C
T U
R A
L E
N G
IN
E
E R
S
S
P
A T
R
IC
K D
R
IV
E S
U
IT
E
I
N D
IA
N
H A
R B
O R
B E
A C
H
F L
O R
ID
A
C O
A
1-
-2
W W
W .A
S E
N G
R .C
O M
As indicated
F O
X L
A K
E
F
O X
L A
K E
R D
T
IT
U
S V
IL
L E
F
L
02/23/26
2024157
JA
JA
TA
S0.0
S T
R U
C T
U R
A L C
O V
E R
S H
E E
T
STRUCTURAL SHEET LIST
Sheet Number Sheet Name
Sheet Issue Date
REVISIONS
Current Revision
Current Revision Date Current Revision Description
S0.0 STRUCTURAL COVER SHEET 02/23/26
S1.0 PLAN 02/23/26
S2.0 DETAILS 02/23/26
A
STRUCTURAL 3D MODEL
(FOR REFERENCE ONLY)
10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"
24' - 4 1/2"
+/- 3.33% SLOPE
ORIGINAL DOCK TO BE REPLACEDNEW ADDITION TO DOCK
17.2
4 1/2" 8' - 0" 8' - 0" 8' - 0"
18.0 18.0 18.0
BOAT ACCESS POINT
OPENING IN RAILING
BOAT ACCESS POINT
OPENING IN RAILING
BOAT ACCESS POINT
OPENING IN RAILING
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
2x10
2x10
2x10
2x10
ALL STRINGERS P.T.
2X10 AT 24" O.C. TYP.
ALL POSTS P.T.
6" Ø AS SHOWN
P.T. 4X4 RAIL SUPPORTS
AS SHOWN
10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 6' - 0" 5' - 7 1/2" 5' - 7" 6' - 0 1/2" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 4 1/2"
.7
/1
S
L O
P E
/2
18.0
18.018.0
/2
BOAT ACCESS POINT
OPENING IN RAILING
BOAT ACCESS POINT
OPENING IN RAILING
x x x x x x x x x x x x x x x x x x x x x x x x x x x x
2x10
2x10
2x10
2x10
2x10
2x10
2x10
ALL STRINGERS
2X10 AT 24" O.C. TYP.
2x10
2x10
2x10
2x10
.7
/1
S
L O
P E
+/- 3.33% SLOPE
ORIGINAL DOCK TO BE REPLACEDNEW ADDITION TO DOCK
17.2 18.0
18.0 18.0
PLAN NORTHPLAN SOUTH
24' - 4 1/2" 243' - 7 1/2"
18.0
PLAN NOTES
1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS SHOWN AND
BRING ANY MAJOR DISCREPANCIES TO THE ATTENTION OF THE ENGINEER
PRIOR TO STARTING WORK.
2. SET ALL POSTS A MINIMUM OF 7'-0" INTO EXISTING GRADE.
3. - DENOTES PROPOSED TOP OF DECK ELEVATION.X.XX
T
HOMA S L . A DAM
S
P R
O F
E
S S
I ONA L ENG
I N E
E R
L I CENSE
F L O R I D A
STATE OF
No. 55343
CCOPYRIGHT STATEMENT
THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF
ADAMS ENGINEERING INC. (AEI) AND ARE ISSUED ONLY FOR THE
SPECIFIC PROJECT NOTED ON THESE DOCUMENTS. ANY REVISIONS,
REPRODUCTIONS OR MODIFICATIONS OF THESE DOCUMENTS WITHOUT THE
EXPRESS WRITTEN CONSENT OF AEI IS PROHIBITED BY LAW.
R E
V
D A
T E
R E
V
IS
IO
N
D R
A W
IN
G
T
IT
L E
PROJ. NO. :
SCALE
DATE
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ENGINEER OF RECORD
THOMAS L. ADAMS, PE
PE #55343
A D
A M
S E
N G
IN
E
E R
IN
G
I N
C
C O
N S
U L
T
IN
G S
T R
U C
T U
R A
L E
N G
IN
E
E R
S
S
P
A T
R
IC
K D
R
IV
E S
U
IT
E
I
N D
R B
O R
B E
A C
H
F L
O R
ID
A
C O
A
1-
-2
W W
W .A
S E
N G
R .C
O M
As indicated
F O
X L
A K
E
F
O X
L A
K E
R D
T
IT
U
S V
IL
L E
F
L
02/23/26
2024157
JA
JA
TA
S1.0
P L A
N
3/16" = 1'-0"
PLAN SOUTH
3/16" = 1'-0"
PLAN NORTH
1/16" = 1'-0"
OVERALL PLAN
/2
/4
/4
T/DECK
SEE PLAN
P.T. 2X10 GIRDER W/ (2)-3/4"Ø S.S.
THRU BOLTS, NUTS AND WASHERS
@ EACH POST
2X6 P.T. DECKING W/ (2)-#10X3" S.S
DECK SCREWS PER BOARD CONN.
P.T. 2X10 PERIMETER JOIST W/ (2)-3/4"Ø S.S.
THRU BOLT, NUTS, AND WASHERS
AT EACH POST
P.T. 2X6 CONT. RAIL W/ (3)-#10X3" S.S.
WOOD SCREWS AT EACH POST
P.T. 2X8 CONT. CAP RAIL W/ (3)-#10X3"
S.S. WOOD SCREWS AT EACH POST
P.T. 2X10 JOISTS AT 24" O.C.
SECURE TO GIRDER WITH SIMPSON
H2.5ASS EACH JOIST, TYP.
/2
/2
WATER LINE
P.T. 6" Ø POST, SEE PLAN.
SET POSTS A MINIMUM OF
7'-0" INTO EXISTING GRADE
T/DECK
SEE PLAN
P.T. 6" Ø POST, SEE PLAN.
SET POSTS A MINIMUM OF
7'-0" INTO EXISTING GRADE
P.T. 2X6 CONT. RAIL W/ (3)-#10X3"
WOOD SCREWS AT EACH POST
P.T. 2X8 CONT. CAP RAIL W/ (3)-#10X3"
WOOD SCREWS AT EACH POST
/4 " 3
/4
P.T. 2X10 GIRDER W/ (2)-3/4"Ø S.S.
THRU BOLTS, NUTS AND WASHERS
@ EACH POST
P.T. 2X10 PERIMETER JOIST W/ (2)-3/4"Ø S.S.
THRU BOLT, NUTS, AND WASHERS
AT EACH POST
WATER LINE
2X6 P.T. DECKING W/ (2)-#10X3" S.S
DECK SCREWS PER BOARD CONN.
T/DECK
SEE PLAN
P.T. 4X4 FOR HANDRAIL SUPPORT
TYP BETWEEN ALL MAIN 6" Ø POSTS.
SEE PLAN
P.T. 2X6 CONT. RAIL W/ (3)-#10X3"
WOOD SCREWS AT EACH POST
P.T. 2X8 CONT. CAP RAIL W/ (3)-#10X3"
WOOD SCREWS AT EACH POST
/4
P.T. 2X10 PERIMETER JOIST W/ (2)-3/4"Ø S.S.
THRU BOLT, NUTS, AND WASHERS
AT EACH POST
2X6 P.T. DECKING W/ (2)-#10X3" S.S
DECK SCREWS PER BOARD CONN.
T
HOMA S L . A DAM
S
P R
O F
E
S S
I ONA L ENG
I N E
E R
L I CENSE
F L O R I D A
STATE OF
No. 55343
CCOPYRIGHT STATEMENT
THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF
ADAMS ENGINEERING INC. (AEI) AND ARE ISSUED ONLY FOR THE
SPECIFIC PROJECT NOTED ON THESE DOCUMENTS. ANY REVISIONS,
REPRODUCTIONS OR MODIFICATIONS OF THESE DOCUMENTS WITHOUT THE
EXPRESS WRITTEN CONSENT OF AEI IS PROHIBITED BY LAW.
R E
V
D A
T E
R E
V
IS
IO
N
D R
A W
IN
G
T
IT
L E
PROJ. NO. :
SCALE
DATE
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ENGINEER OF RECORD
THOMAS L. ADAMS, PE
PE #55343
A D
A M
S E
N G
IN
E
E R
IN
G
I N
C
C O
N S
U L
T
IN
G S
T R
U C
T U
R A
L E
N G
IN
E
E R
S
S
P
A T
R
IC
K D
R
IV
E S
U
IT
E
I
N D
R B
O R
B E
A C
H
F L
O R
ID
A
C O
A
1-
-2
W W
W .A
S E
N G
R .C
O M
3/4" = 1'-0"
F O
X L
A K
E
F
O X
L A
K E
R D
T
IT
U
S V
IL
L E
F
L
02/23/26
2024157
JA
JA
TA
S2.0
D E
T A
IL
S
3/4" = 1'-0"
DETAIL
3/4" = 1'-0"
DETAIL
3/4" = 1'-0"
DETAIL
| Sheets |
| S0.0 - STRUCTURAL COVER SHEET |
| S1.0 - PLAN |
| S2.0 - DETAILS |
| 2026-02-23T11:16:13-0500 | |
| Thomas L Adams |
| 2026-02-23T11:16:14-0500 | |
| Thomas L Adams |
| 2026-02-23T11:16:14-0500 | |
| Thomas L Adams |
File details come from the government source that posted it. Updated .