Attachment_B__Structural_Drawings.pdf

PDF 1006 KB Posted

Attached to
Fox Lake Park Boat Ramp Dock Replacement
Solicitation number
B-8-26-39
Issued by
Brevard County, Florida

About this file

Fox Lake Park Boat Ramp Dock Replacement - Structural Drawings Summary

This attachment contains structural drawings prepared by Adams Engineering Inc. for Brevard County, Florida's Fox Lake Park Boat Ramp Dock Replacement project. The project involves demolition of the existing dock and installation of a new replacement structure at 4400 Fox Lake Road, Titusville, Florida. The structural design is engineered in accordance with the 2023 Florida Building Code and ASCE-7-22 standards, with design criteria including a 60 PSF uniform live load on the deck, 160 MPH wind speed (3-second gust), Risk Category II, and Exposure D. The dock structure measures approximately 243 feet 7½ inches in length with a 24-foot 4½-inch width, featuring a ±3.33% slope and three boat access point openings in the railing. The structural system utilizes pressure-treated Southern Yellow Pine lumber with stainless steel hardware and connections throughout, with all posts set a minimum of 7 feet into existing grade.

The drawings specify construction details for the dock decking, joists, girders, posts, rails, and cap rails, with all structural lumber meeting minimum No. 1 grade for decking, railing, and cap board components and No. 2 grade for girders, joists, and stringers. Materials include 2x6 pressure-treated decking, 2x10 joists at 24-inch on-center spacing, 2x10 girders, 6-inch octagonal posts, 4x4 rail supports, and 2x6 and 2x8 continuous rail components secured with 3/4-inch stainless steel through bolts and #10x3-inch stainless steel deck screws. The contractor must submit a Shipping, Stockpile and Site Administration Plan (SSSAP), Maintenance of Traffic Plan (MOTP), and Site-Specific Safety Plan for approval prior to commencing work, and is responsible for acquiring all necessary building permits, maintaining a clean construction site with designated debris areas, and restoring all facilities and landscaping to original condition following project completion.

View the file

Other files

File Type Posted
Notice_of_Award.pdf PDF
Bid_Tabulation.pdf PDF
Bid_Tabulation__Names_Only.pdf PDF
Bid_Tabulation__Names_Only.pdf PDF
Addendum_2.pdf PDF
Fox_Lake_dock_2.jpg JPG image
SSFOX_LAKE_PARKBid_Set_7826.pdf PDF
Fox_Lake_dock.jpg JPG image
Fox_Lake_dock_2.jpg JPG image
Fox_lake_dock_3.jpg JPG image
SSFOX_LAKE_PARKBid_Set_7826.pdf PDF
Addendum_2.pdf PDF
Fox_lake_dock_3.jpg JPG image
Fox_Lake_dock.jpg JPG image
Fox_Lake_dock_4.jpg JPG image
Fox_lake_dock_5.jpg JPG image
Fox_Lake_dock_4.jpg JPG image
Fox_lake_dock_5.jpg JPG image
Addendum_1.pdf PDF
Addendum_1.pdf PDF
Attachment_A__Survey.pdf PDF
Attachment_A__Survey.pdf PDF
B82639_INV__SPECS.pdf PDF
B82639_INV__SPECS.pdf PDF
Attachment_C__Draft_Contract.pdf PDF
Attachment_B__Structural_Drawings.pdf PDF
Attachment_C__Draft_Contract.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MATERIAL IDENTIFICATIONS

THE FOLLOWING MATERIAL IDENTIFICATIONS MAY BE USED IN THE STRUCTURAL DRAWINGS:

CONCRETE EARTH GRAVEL GROUT

MASONRY STEEL LT GAGE WOOD

DRAWING INTERPRETATION:

DRAWING VIEWS LABELED AS "TYPICAL":

PARTIAL PLANS, ELEVATIONS, SECTIONS, DETAIL, OR SCHEDULES LABELED WITH "TYPICAL"

BEGINNING OF THIER TITLE APPLY TO SITUATIONS OCCURING ON A PROJECT THAT ARE SAME

OR SIMILAR TO THOSE INDICATED WHETHER OR NOT THEY ARE KEYED AT EACH LOCATION.

APPLICABILITY CAN BE DETERMINED BY THE TITLE OF EACH VIEW.

VIEW REFERENCE SYMBOLS

THE FOLLOWING SYMBOLS MAY BE USED TO REFER TO OTHER VIEWS IN THE DRAWINGS:

ELEVATION SYMBOL

X

SX.X

ELEVATION

NUMBER

SHEET

NUMBER

DETAIL

NUMBER

SHEET

NUMBER

DETAIL SYMBOL

SECTION SYMBOL

SECTION

NUMBER

SHEET

NUMBER

ALL WOOD FRAMING CONSTRUCTION, WORKMANSHIP AND

MATERIALS SHALL CONFORM WITH THE SPECIFICATIONS AND

REQUIREMENTS OF THE REFERENCES LISTED BELOW:

*"AMERICAN INSTITUTE OF TIMBER CONSTRUCTION"

*"NATIONAL DESIGN SPECIFICATION FOR WOOD"

CONSTRUCTION" 2005 AND SUPPLEMENT.

TIMBER

USE CATEGORY

ALL STRUCTURAL LUMBER SHALL BE AS A MINIMUM,

NO.1 GRADE SOUTHERN YELLOW PINE FOR DECKING,

RAILING, CAP BOARD, POSTS, TYP. AND NO.2 SOUTHERN

GRADE YELLOW PINE FOR GIRDERS, JOISTS, STRINGERS,

AND SHALL HAVE AT LEAST THE FOLLOWING MINIMUM

ALLOWABLE DESIGN STRESSES AND MODULUS OF

ELASTICITY AT A MAXIMUM MOISTURE CONTENT OF 19":

1.

2.

Fb (BENDING) Fv (SHEAR) Fc (COMPRESSION) Ft (TENSION) E

1500 PSI

90 PSI

1650 PSI

825 PSI

1,6000,000 PSI

2X4 TIMBER

1250 PSI

90 PSI

1600 PSI

725 PSI

1,6000,000 PSI

2X6 TIMBER

1200 PSI

90 PSI

1550 PSI

650 PSI

1,6000,000 PSI

2X8 TIMBER

Fb (BENDING) Fv (SHEAR) Fc (COMPRESSION) Ft (TENSION) E

1050 PSI

90 PSI

1500 PSI

575 PSI

1,6000,000 PSI

2X10 TIMBER

975 PSI

90 PSI

1450 PSI

550 PSI

1,6000,000 PSI

2X12 TIMBER

ALL LUMBER SHALL BE FACTORY MARKED WITH GRADE

STAMP OF INSPECTION AGENCY, SHOWING COMPLIANCE

WITH GRADING RULE REQUIREMENTS

3.

STAINLESS STEEL HANGERS AND FRAMING ANCHORS SHALL

BE USED AND SHALL BE FASTENED IN ACCORDANCE WITH

THE MANUFACTURERS SPECIFICATIONS

4.

ANCHORING AND NAILING NOT SPECIFIED SHALL COMPLY

WITH THE NAILING SCHEDULE PER THE FBC

5.

USE CATEGORY UC5C MARINE USE SOUTHERN WATERS OF

THE AMERICAN WOOD PROTECTION ASSOCIATION U1-18

6.

PRESERVATIVE RETENTION SPECIFICATIONS (SOLID SAWN MATERIALS, MARINE APPLICATION)

SOUTHERN PINE,

MIXED SOUTHERN PINE

RETENTION SPECIFICATION SOLID SAWN MATERIAL

CR/CR-S ACZA CCA

25 2.5 2.5

ALL FACILITIES, PRIVATE OR PUBLIC, USED FOR ACCESS SHALL BE

REPAIRED TO THEIR ORIGINAL CONDITION FOLLOWING "COMPLETION"

OF THE PROJECT, INCLUDING GRADE AND TOPPING (SOD,

TREE/VEGITATION COVER, ESTABLISHED ROAD, ETC.)

MOBILIZATION AND DEMOBILIZATION

1.

THE CONTRACTOR PRESENT A SHIPPING, STOCKPILE AND SITE

ADMINISTRATION PLAN (SSSAP) TO THE OWNER, OWNER'S

REPRESENTATIVEOR ENGINEER FOR APPROVAL. THE PLAN SHALL BE

SPECIFIC TO THE PROJECT REQUIREMENTS FOR THE PARTICULAR

MATERIALS TO BE DELIVERED TO THE SITE, DESCRIBING DELIVERY

POINTS, STOCKPILE AREAS, TEMPORARILY DEBRIS/TRASH STORAFE

AREAS, TEMPORARY FIELD OFFICE (INCL. UTILITIES MAINTAINED THERE),

FENCING, SECURITY ABD A STATEMENT OF COMMITMENT AND DETAILS

FOR MAINTAINING SAFETY ON THE SITE.

2.

THE OWNER, OWNER'S REP OR ENGINEER SHALL HAVE THE RIGHT TO

EXERCISE REASONABLE ALTERATIONS OR ADDITIONS TO THE SSSAP.

3.

IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE, AND PAY FOR,

NECESSARY UTILITIES TO OCCUPY THE SITE AND PERFORM THE WORK

4.

THE CONTRACTOR SHALL NOT DEMOBILIZE UNTIL PROJECT COMPLETION5.

THE CONTRACTOR SHALL PROVIDE "ACCESS CLOSED FOR

CONSTRUCTION" SIGNS - "NO TRESPASSING" AND BARACADES OFF OF

THE BEACH ACCESS

6.

THE CONTRACTOR SHALL MAINTAIN A CLEAN AND NEAT SITE, VOID OF

LOOSE DEBRIS, TRASH, REMNANT PARTS OR MATERIALS.

SITE MAINTENANCE

1.

TRASH RECEPTACLES AND REMOVAL SERVICE SHALL BE MAINTAINED BY

THE CONTRACTOR SPECIFICALLY FOR THIS PROJECT. PRE-EXISTING

TRASH/DEBRIS FACILITIES SHALL NOT BE USED TO MAINTAIN THE PROJECT

2.

TEMPORARY DEBRIS PILES SHALL BE LIMITED IN NUMBER AS MUCH AS

PRACTICAL AND CONTAINED IN DESIGNATED AREAS UNTIL REMOVAL.

DEBRIS AND TRASH SHALL NOT BE SCATTERED IN AREAS OUTSIDE THE

LIMITED DESIGNATED AREAS AT ANY TIME.

3.

REMOVAL OF TRASH/DEBRIS SHALL BE SCHEDULED AS APPROPRIATE TO

NOT ALLOW PILES TO REACH FIVE FEET IN HEIGHT OR GREATER THEN TEN

FEET IN DIAMETER. DEBRIS INDIVIDUALLY LARGER THEN THESE

DIMENSIONS SHALL BE REMOVED FROM THE SITE WITHIN FIVE WORKING

DAYS. RECEPTACLES SHALL NOT OVERFLOW AT ANY TIME. CONTAIN AND

PROTECT ALL DEBRIS FROM BECOMING WIND BOURNE.

4.

WHERE NECESSARY, THE CONTRACTOR SHALL EMPLOY A MAINTENANCE

OF TRAFFIC PLAN (MOTP) FOR VEHICLES AND PEDESTRIANS INCLUDING

MATERIAL DELIVERIES, STOCKPILE AREA(S), WORKER PARKING AND

CONSTRUCTION EQUIPMENT. THE PLAN MUST BE IN WRITING, INCLUDING

SKETCHES OR DRAWINGS, AND MUST BE SUBMITTED TO THE OWNER,

OWNER'S REP OR ENGINEER FOR REVIEW AND APPROVAL BEFORE

COMMENCEMENT OF ANY WORK.

5.

THE CONTRACTOR SHALL FOLLOW ALL APPLICABLE LOCAL, STATE AND

FEDERAL CODES REGARDING SITE MAINTENANCE.

6.

THE CONTRACTOR SHALL PREPARE AND ADHERE TO A SITE-SPECIFIC

SAFETY PLAN. THE CONTENTS OF THE PLAN ARE:

1. IDENTIFICATION OF POTENTIAL HAZARDS AND INJURIES PERTAINING

TO THE SPECIFIC SITE AND PROJECT.

2. LOCATION NEAREST HOSPITAL.

3. ASSURE AVAILABILITY OF AT LEAST ONE WORKING CELL PHONE AND

ONE VEHICLE ON SITE AT ALL TIMES.

4. EMERGENCY CONTACTS WITHIN THE SUBCONTRACTORS

ORGANIZATION AND AT THE PRIME CONTRACTORS ORGANIZATION.

5. ALL FIELD PERSONNEL WEAR APPROPRIATE PERSONAL PROTECTION

EQUIPMENT FOR A GIVEN TASK/OPERATION SUCH AS SAFETY

GLASSES/GOGGLES, MASKS, SHIELDS, GLOVES, HARNESSES, HARD

HATS, STEEL-TOED BOOTS, ETC.

6. SAFETY KIT AVAILABLE ONSITE AT ALL TIMES WITH MATERIALS FOR

POTENTIAL HAZARDS AND INJURIES.

7. THE SITE SPECIFIC SAFETY PLAN SHALL BE DISTRIBUTED AND

REVIEWED WITH ALL SITE WORKERS PRIOR TO SAID WORKERS

COMMENCING WORK ON THE PROJECT SITE.

8. THE CONTRACTOR SHALL FOLLOW ALL APPLICABLE LOCAL, STATE

AND FEDERAL CODES REGARDING SITE SAFETY.

SITE SAFETY

LOCATION MAP

DOCK LOCATION

DEMOLITION OR CLEARING MAY REQUIRE PERMITS. THE CONTRACTOR

SHALL ACQUIRE ALL NECESSARY BUILDING PERMITS FROM THE LOCAL

MUNICIPALITY PRIOR TO COMMENCING WORK.

DEMOLITION, CLEARING AND RESTORATION

1.

CLEARING AND REMOVAL OF VEGITATION, ROCKS AND DEBRIS MAY BE

REQUIRED WITHIN THE PROJECT STRUCTURE FOOTPRINT.

2.

DEMOLITION OR REMOVAL OF OBJECTS, DEBRIS, OR MATERIAL

SPECIFIED OR OBSTRUCTING CONSTRUCTION SHALL TAKE PLACE ONLY

TO THE EXISTING EXTENT NECESSARY

3.

ANY PERMITTED DEMOLITION OR REMOVAL FROM SUBMERGED LANDS

OR ADJACENT UPLANDS SHALL BE FULLY CONTAINED WITHIN SILTATION

DEVICES SUCH THAT PERMIT TURBIDITY REQUIREMENTS AND STATE

WATER QUALITY STANDARDS ARE MET.

4.

THE SITE SHALL BE RESTORED BY REMOVING AND FINISHING ALL

EVIDENCE OF CONSTRUCTION INCLUDING TEMPORARILY HAUL ROADS,

VEHICLE RUTS, STOCKPILE AREAS, SHORELINE SLOPES AND

VEGITATION, SOD AND AREAS SUBJECT TO PROJECT WORK.

5.

ALL STRUCTURAL WORK FOR THIS PROJECT HAS BEEN ENGINEERED

IN ACCORDANCE WITH: THE FLORIDA BUILDING CODE, 2023 ASCE-7 22

"MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES.

ALL CONSTRUCTION SHALL COMPLY WITH THE REQUIREMENTS AND

SPECIFICATIONS OF THESE CODES AND THEIR REFERENCED

STANDARDS, AND ALL OTHER APPLICABLE FEDERAL, STATE, AND

LOCAL CODES, STANDARDS, REGULATIONS AND LAWS.

DESIGN CRITERIA

DESIGN GRAVITY LOADS:

LOCATION UNIFORM LIVE LOAD

DECK 60 PSF

DESIGN WIND LOADS:

WIND SPEED: (3 SECOND GUST) V=160 MPH

RISK CATEGORY: CATEGORY II

EXPOSURE: D

T

HOMA S L . A DAM

S

P R

O F

E

S S

I ONA L ENG

I N E

E R

L I CENSE

F L O R I D A

STATE OF

No. 55343

CCOPYRIGHT STATEMENT

THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF

ADAMS ENGINEERING INC. (AEI) AND ARE ISSUED ONLY FOR THE

SPECIFIC PROJECT NOTED ON THESE DOCUMENTS. ANY REVISIONS,

REPRODUCTIONS OR MODIFICATIONS OF THESE DOCUMENTS WITHOUT THE

EXPRESS WRITTEN CONSENT OF AEI IS PROHIBITED BY LAW.

R E

V

D A

T E

R E

V

IS

IO

N

D R

A W

IN

G

T

IT

L E

PROJ. NO. :

SCALE

DATE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ENGINEER OF RECORD

THOMAS L. ADAMS, PE

PE #55343

A D

A M

S E

N G

IN

E

E R

IN

G

I N

C

C O

N S

U L

T

IN

G S

T R

U C

T U

R A

L E

N G

IN

E

E R

S

S

P

A T

R

IC

K D

R

IV

E S

U

IT

E

I

N D

IA

N

H A

R B

O R

B E

A C

H

F L

O R

ID

A

C O

A

1-

-2

W W

W .A

S E

N G

R .C

O M

As indicated

F O

X L

A K

E

F

O X

L A

K E

R D

T

IT

U

S V

IL

L E

F

L

02/23/26

2024157

JA

JA

TA

S0.0

S T

R U

C T

U R

A L C

O V

E R

S H

E E

T

STRUCTURAL SHEET LIST

Sheet Number Sheet Name

Sheet Issue Date

REVISIONS

Current Revision

Current Revision Date Current Revision Description

S0.0 STRUCTURAL COVER SHEET 02/23/26

S1.0 PLAN 02/23/26

S2.0 DETAILS 02/23/26

A

STRUCTURAL 3D MODEL

(FOR REFERENCE ONLY)

10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"

24' - 4 1/2"

+/- 3.33% SLOPE

ORIGINAL DOCK TO BE REPLACEDNEW ADDITION TO DOCK

17.2

4 1/2" 8' - 0" 8' - 0" 8' - 0"

18.0 18.0 18.0

BOAT ACCESS POINT

OPENING IN RAILING

BOAT ACCESS POINT

OPENING IN RAILING

BOAT ACCESS POINT

OPENING IN RAILING

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

2x10

2x10

2x10

2x10

ALL STRINGERS P.T.

2X10 AT 24" O.C. TYP.

ALL POSTS P.T.

6" Ø AS SHOWN

P.T. 4X4 RAIL SUPPORTS

AS SHOWN

10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 6' - 0" 5' - 7 1/2" 5' - 7" 6' - 0 1/2" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 4 1/2"

.7

/1

S

L O

P E

/2

18.0

18.018.0

/2

BOAT ACCESS POINT

OPENING IN RAILING

BOAT ACCESS POINT

OPENING IN RAILING

x x x x x x x x x x x x x x x x x x x x x x x x x x x x

2x10

2x10

2x10

2x10

2x10

2x10

2x10

ALL STRINGERS

2X10 AT 24" O.C. TYP.

2x10

2x10

2x10

2x10

.7

/1

S

L O

P E

+/- 3.33% SLOPE

ORIGINAL DOCK TO BE REPLACEDNEW ADDITION TO DOCK

17.2 18.0

18.0 18.0

PLAN NORTHPLAN SOUTH

24' - 4 1/2" 243' - 7 1/2"

18.0

PLAN NOTES

1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS SHOWN AND

BRING ANY MAJOR DISCREPANCIES TO THE ATTENTION OF THE ENGINEER

PRIOR TO STARTING WORK.

2. SET ALL POSTS A MINIMUM OF 7'-0" INTO EXISTING GRADE.

3. - DENOTES PROPOSED TOP OF DECK ELEVATION.X.XX

T

HOMA S L . A DAM

S

P R

O F

E

S S

I ONA L ENG

I N E

E R

L I CENSE

F L O R I D A

STATE OF

No. 55343

CCOPYRIGHT STATEMENT

THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF

ADAMS ENGINEERING INC. (AEI) AND ARE ISSUED ONLY FOR THE

SPECIFIC PROJECT NOTED ON THESE DOCUMENTS. ANY REVISIONS,

REPRODUCTIONS OR MODIFICATIONS OF THESE DOCUMENTS WITHOUT THE

EXPRESS WRITTEN CONSENT OF AEI IS PROHIBITED BY LAW.

R E

V

D A

T E

R E

V

IS

IO

N

D R

A W

IN

G

T

IT

L E

PROJ. NO. :

SCALE

DATE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ENGINEER OF RECORD

THOMAS L. ADAMS, PE

PE #55343

A D

A M

S E

N G

IN

E

E R

IN

G

I N

C

C O

N S

U L

T

IN

G S

T R

U C

T U

R A

L E

N G

IN

E

E R

S

S

P

A T

R

IC

K D

R

IV

E S

U

IT

E

I

N D

R B

O R

B E

A C

H

F L

O R

ID

A

C O

A

1-

-2

W W

W .A

S E

N G

R .C

O M

As indicated

F O

X L

A K

E

F

O X

L A

K E

R D

T

IT

U

S V

IL

L E

F

L

02/23/26

2024157

JA

JA

TA

S1.0

P L A

N

3/16" = 1'-0"

PLAN SOUTH

3/16" = 1'-0"

PLAN NORTH

1/16" = 1'-0"

OVERALL PLAN

/2

/4

/4

T/DECK

SEE PLAN

P.T. 2X10 GIRDER W/ (2)-3/4"Ø S.S.

THRU BOLTS, NUTS AND WASHERS

@ EACH POST

2X6 P.T. DECKING W/ (2)-#10X3" S.S

DECK SCREWS PER BOARD CONN.

P.T. 2X10 PERIMETER JOIST W/ (2)-3/4"Ø S.S.

THRU BOLT, NUTS, AND WASHERS

AT EACH POST

P.T. 2X6 CONT. RAIL W/ (3)-#10X3" S.S.

WOOD SCREWS AT EACH POST

P.T. 2X8 CONT. CAP RAIL W/ (3)-#10X3"

S.S. WOOD SCREWS AT EACH POST

P.T. 2X10 JOISTS AT 24" O.C.

SECURE TO GIRDER WITH SIMPSON

H2.5ASS EACH JOIST, TYP.

/2

/2

WATER LINE

P.T. 6" Ø POST, SEE PLAN.

SET POSTS A MINIMUM OF

7'-0" INTO EXISTING GRADE

T/DECK

SEE PLAN

P.T. 6" Ø POST, SEE PLAN.

SET POSTS A MINIMUM OF

7'-0" INTO EXISTING GRADE

P.T. 2X6 CONT. RAIL W/ (3)-#10X3"

WOOD SCREWS AT EACH POST

P.T. 2X8 CONT. CAP RAIL W/ (3)-#10X3"

WOOD SCREWS AT EACH POST

/4 " 3

/4

P.T. 2X10 GIRDER W/ (2)-3/4"Ø S.S.

THRU BOLTS, NUTS AND WASHERS

@ EACH POST

P.T. 2X10 PERIMETER JOIST W/ (2)-3/4"Ø S.S.

THRU BOLT, NUTS, AND WASHERS

AT EACH POST

WATER LINE

2X6 P.T. DECKING W/ (2)-#10X3" S.S

DECK SCREWS PER BOARD CONN.

T/DECK

SEE PLAN

P.T. 4X4 FOR HANDRAIL SUPPORT

TYP BETWEEN ALL MAIN 6" Ø POSTS.

SEE PLAN

P.T. 2X6 CONT. RAIL W/ (3)-#10X3"

WOOD SCREWS AT EACH POST

P.T. 2X8 CONT. CAP RAIL W/ (3)-#10X3"

WOOD SCREWS AT EACH POST

/4

P.T. 2X10 PERIMETER JOIST W/ (2)-3/4"Ø S.S.

THRU BOLT, NUTS, AND WASHERS

AT EACH POST

2X6 P.T. DECKING W/ (2)-#10X3" S.S

DECK SCREWS PER BOARD CONN.

T

HOMA S L . A DAM

S

P R

O F

E

S S

I ONA L ENG

I N E

E R

L I CENSE

F L O R I D A

STATE OF

No. 55343

CCOPYRIGHT STATEMENT

THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF

ADAMS ENGINEERING INC. (AEI) AND ARE ISSUED ONLY FOR THE

SPECIFIC PROJECT NOTED ON THESE DOCUMENTS. ANY REVISIONS,

REPRODUCTIONS OR MODIFICATIONS OF THESE DOCUMENTS WITHOUT THE

EXPRESS WRITTEN CONSENT OF AEI IS PROHIBITED BY LAW.

R E

V

D A

T E

R E

V

IS

IO

N

D R

A W

IN

G

T

IT

L E

PROJ. NO. :

SCALE

DATE

DESIGNED BY:

DRAWN BY:

CHECKED BY:

ENGINEER OF RECORD

THOMAS L. ADAMS, PE

PE #55343

A D

A M

S E

N G

IN

E

E R

IN

G

I N

C

C O

N S

U L

T

IN

G S

T R

U C

T U

R A

L E

N G

IN

E

E R

S

S

P

A T

R

IC

K D

R

IV

E S

U

IT

E

I

N D

R B

O R

B E

A C

H

F L

O R

ID

A

C O

A

1-

-2

W W

W .A

S E

N G

R .C

O M

3/4" = 1'-0"

F O

X L

A K

E

F

O X

L A

K E

R D

T

IT

U

S V

IL

L E

F

L

02/23/26

2024157

JA

JA

TA

S2.0

D E

T A

IL

S

3/4" = 1'-0"

DETAIL

3/4" = 1'-0"

DETAIL

3/4" = 1'-0"

DETAIL

Sheets
S0.0 - STRUCTURAL COVER SHEET
S1.0 - PLAN
S2.0 - DETAILS
2026-02-23T11:16:13-0500
Thomas L Adams
2026-02-23T11:16:14-0500
Thomas L Adams
2026-02-23T11:16:14-0500
Thomas L Adams

File details come from the government source that posted it. Updated .