Attachment B - RLP 1TX2688 - Agency Special Requirements 9-11-2018.pdf

PDF 149 KB Posted

Attached to
General Services Administration (GSA) seeks to lease the following space: Fort Worth, Texas
Solicitation number
1314
Issued by

About this file

This document contains agency-specific requirements for a NOAA warehouse facility in Fort Worth, Texas. NOAA will occupy the space to store spare equipment parts, weather devices, and replacement parts, with a designated work area for repairing and modifying weather equipment. The facility must be located within a delineated area of Fort Worth bounded by I-820 (north), FM1187E to Debbie Lane to I-360 (east), I-820 to 377S to FM1187E (south), and I-360 to I-30 to I-820 to I-820N (west), and must be zoned industrial.

The facility must include weather/moisture resistant, commercial-grade electrical outlets—specifically a 240 VAC 20 AMP duplex outlet and a 120 VAC duplex outlet, both grounded per code—for equipment repair work. Restroom facilities are required either adjacent to or with easy access to the space, with cleaning responsibilities specified. Parking provisions must accommodate two secure parking or wareyard spaces for twenty-foot trailers available 24/7, with circulation area for equipment movement and available surface parking for employees. The facility must accommodate a 23-foot work truck with specified turning radius for material pickup and drop-off. Security must meet Facility Security Level I standards. Trash disposal may utilize existing dumpsters on the premises, with no dedicated or additional dumpsters required for the government.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AGENCY SPECIFIC REQUIREMENTS

NOAA Warehouse Space, Fort Worth, TX

Description:

NOAA will use the space to store spare equipment parts and NOAA Weather devises and replacement parts. A portion of the space will be used as a work area to repair and modify NOAA Weather equipment and devises

Electrical Requirements:

Space to be lit and include a) weather/moisture resistant, commercial grade 240 V AC 20 AMP duplex outlet and grounded per code; and, b) weather/moisture resistant commercial !:,Jfade 120 VAC duplex, also grounded per code.

Outlets will be used to work on and repair NOAA Weather equipment and devises.

Restrooms or Easy Access to Restrooms:

Restrooms for employees are required either adjacent to the space or easy of access to restrooms.

If restrooms built-out as part of the space, additional space may be necessary for warehouse area storage and work area.

Cleaning of restroom whether in the space or adjacent to the space is required.

Delineated Area:

Within the City of Fort Worth, Texas bounded by:

North: 1-820 East: FM1187E to Debbie Lane to I-360 South: I-820 to 377S to FM1187E West: I-360 to I-30 to I-820 to I-820N

Zoning must be industrial.

Parking:

Two secure parking or wareyard area for two separate twenty (20) foot trailers to be left at the site 24/7.

Area should include circulation for access to move equipment, materials and devises in and out of both twenty (20) foot trailers.

Available surface parking for employee access.

Ability to drive at least a 23-foot work truck up to warehouse space for pick-up and drop-off of materials, tools and miscellaneous equipment, turning radius attached.

Security:

Facility Security Level I

Trash & Dumpster(s):

NOAA may use existing dumpsters located on the premises, no dedicated or additional dumpsters are required for the Government.

TorrenceLBorden Typewriter 9/11/2018

TorrenceLBorden Typewriter RLP 1TX2688, GS-07P-LTX01242, Attachment "B"

Untitled

File details come from the government source that posted it. Updated .