Attachment B - QASP.pdf

PDF 101 KB Posted

Attached to
N3943021R2307-Geothermal Program Office, PW68 Steam Transfer Flow Rate Verification
Solicitation number
N3943021R2307
Issued by

View the file

Other files

File Type Posted
Attachment C - RFI.docx DOCX document
Attachment E- Financial Institution Bank Information.pdf PDF
N3943021R2307 Solicitation.pdf PDF
Attachment A- CDRL.docx DOCX document
Attachment D- Past Performance Questionnaire Cover sheet.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

QUALITY ASSURANCE SURVEILLANCE PLAN

for Steam Flow Rate Verification

This Quality Assurance Surveillance Plan (QASP) has been developed to evaluate contractor actions. It is designed to provide an effective surveillance method of monitoring contractor performance for the installation contract.

The QASP provides a systematic method to evaluate the services the contractor is required to furnish.

This QASP is based on the premise the Government desires to maintain a quality standard for verification of the steam flow rates of steam being measured and transferred from one lease property to another at the Coso geothermal field and that a service contract to provide this service is the best means of achieving that objective.

The Contractor, and not the Government, is responsible for management and quality control actions to meet the terms of the contract. The role of the Government is quality assurance to ensure contract standards are achieved.

Performance

Objective

Performance

Standards

Acceptable

Quality Levels

Method Used/

Frequencies

Collect and analyze

Coso steam flow rates for the three steam transfer sites (Navy I to

Navy II, BLM North to

Navy I, and Navy II to

BLM) for duration of the contract: FY2021 (base year), FY2022 (option year 1), FY2023 (option year 2), FY2024 (option year 3) and FY2025

(option year 4).

The Contractor shall submit within 30 days via email, the analysis results for the samples collected.

QA/QC and analysis shall be thoroughly conducted and at industry standards and maintaining historical consistency.

Government Representative shall review submitted analysis results and provide comments to Contractor as necessary.

File details come from the government source that posted it. Updated .