Attachment_B_-_ASTM-F2208-08.pdf

ASTM Standard 2008 edition PDF 142 KB Posted

Attached to
Purchase of Pool and Door Alarms
Solicitation number
RFQ-604681-23/MHH
Issued by
Seminole County, Florida

About this file

The document is an ASTM International Standard Safety Specification (F2208-08) for Residential Pool Alarms, developed under the jurisdiction of ASTM Committee F15 on Consumer Products. The standard provides comprehensive safety and performance requirements for pool alarms designed to detect unintentional or unsupervised entry of children one year of age or older into swimming pools or spas. It covers four different types of alarms: Surface (Type A), Subsurface (Type B), Pool Perimeter (Type C), and Personal Immersion Alarm (Type D). The specification outlines detailed performance requirements, including alarm sound characteristics, battery indicators, automatic reset capabilities, and specific testing procedures using a child intrusion simulator called "Rescue Timmy".

The standard addresses a critical safety need, referencing Consumer Product Safety Commission (CPSC) data indicating an average of 256 children under 5 years old drown in swimming pools annually, with over 2,000 children treated in emergency rooms for pool submersion injuries. While not intended to replace other safety measures like adult supervision, fences, and locks, the specification provides rigorous technical requirements for pool alarm manufacturers. Key performance requirements include sounding alarms both poolside and inside adjacent residences within 20 seconds, maintaining a minimum 85 dBA sound pressure rating, providing low-battery indicators, and complying with FCC wireless communication regulations. The standard emphasizes that these alarms are designed to improve personal safety and reduce potential injuries or deaths in residential pool settings.

View the file

Who attaches ASTM F2208

State Files
Florida 1

Other files

File Type Posted
Purchase_of_Pool_and_Door_Alarms.pdf PDF
Attachment_C_-_Safety_Barrier_Guidelines.pdf PDF
FEMA_REQUIREMENTS.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Designation: F2208 − 08

StandardSafety Specification for Residential Pool Alarms1

This standard is issued under the fixed designation F2208; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.

INTRODUCTION

According to Consumer Product Safety Commission (CPSC) data, it is estimated that each year on average 256 children under 5 years of age drown in swimming pools, with most deaths occurring in residential settings. Additionally, each year on average over 2000 children under 5 years of age are treated in hospital emergency rooms for pool submersion injuries.

1. Scope

1.1 This safety specification covers safety and performance

requirements for pool alarms for residential swimming pools and spas.

1.2 This safety specification describes devices intended to

improve personal safety and reduce injuries or deaths.

1.3 This safety specification covers devices that provide for rapid and automatic detection and alarm in cases of unintentional, unsupervised or accidental entry of a child one year of age or older into the water of swimming pools or spas.

1.4 This safety specification is not intended to replace other standard safety requirements that should be in place, that is, adult supervision, fences, gates, locks, and so forth.

1.5 This safety specification covers four different types of

alarms.

1.6 The detection criteria for this safety specification is for a child one year of age and older.

1.7 The values stated in inch-pound units are to be regarded

as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.8 This standard does not purport to address all of the

safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.

2. Referenced Documents

2.1 ANSI Standards:2

ANSI Z535.4 Product Safety Signs and Labels ANSI Z535.6 Product Safety Information and Product

Manuals, Instructions, and Other Collateral Materials

3. Terminology

3.1 Definitions of Terms Specific to This Standard:

3.1.1 lot, n—normal production run or in the case of imports, a shipment of items produced in the same time frame.

3.1.2 pool alarm, n—device designed to provide a rapid detection and automatic alarm in incidents of accidental, unintentional or unsupervised entry of a child one year of age or older into the water of a swimming pool or spa.

4. Classification

4.1 Types:

4.1.1 Type A, Surface—Pool alarm floating on water surface.

4.1.2 Type B, Subsurface—Pool alarm located below the

water surface.

4.1.3 Type C, Pool Perimeter—Pool alarm located such as

to detect movement at the perimeter of or above the water surface.

4.1.4 Type D, Personal Immersion Alarm—Pool alarm de-

vice located on the person(s).

5. Performance Requirements

5.1 General:

5.1.1 Alarms shall sound both at poolside and inside any

adjacent residence or building of occupancy via a remote receiver within 20 s or less when tested in accordance with Section 6.1 This specification is under the jurisdiction of ASTM Committee F15 on

Consumer Products and is the direct responsibility of Subcommittee F15.49 on Pool Safety Standards.

Current edition approved May 1, 2008. Published June 2008. Originally approved in 2002. Last previous edition approved in 2007 as F2208 – 07. DOI:

10.1520/F2208-08.

2 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.

Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.

Contact ASTM International (www.astm.org) for the latest information iTeh Standards (https://standards.iteh.ai)

Document Preview

ASTM F2208-08

https://standards.iteh.ai/catalog/standards/sist/909f683a-5a7d-4e8f-8286-fdbe84f7cd69/astm-f2208-08 http://www.astm.org/COMMIT/COMMITTEE/F15.htm http://www.astm.org/COMMIT/SUBCOMMIT/F1549.htm https://standards.iteh.ai/catalog/standards/sist/909f683a-5a7d-4e8f-8286-fdbe84f7cd69/astm-f2208-08

5.1.2 The operational condition of a swimming pool alarm, either on or off, shall be indicated with an energized lamp or other distinctive indicator, visible from a distance of 10 6 1 ft (3 6 0.3 m) at angles of 45 6 5° perpendicular to the unit to indicate the operability of the product.

5.1.3 Pool alarms shall have a minimum sound pressure

rating of 85 dBA at 10 ft (3.5 m) for 3 min.

5.1.4 If the device is battery operated, there shall be a

low-battery indicator. A low-battery condition is defined as an inability to meet the requirements of 5.1.3.

5.1.5 Pool alarms shall automatically reset.

5.1.6 Pool alarm manufacturers who employ wireless com-

munication (RF) shall comply with all relevant provisions of FCC Part-15 rules for unlicensed radio frequency devices including the required compliance labeling and statement.

5.1.7 If the alarm deactivates or has reduced sensitivity due to environmental factors, the alarm shall indicate this in both a visual and audible manner.

5.2 Type A, Surface Alarm:

5.2.1 Type A alarms shall provide for the automatic sound of

the alarm when tested in accordance with 6.1. For alarms with variable sensitivity, the setting shall be set at the least sensitive, according to manufacturer’s instructions.

5.2.2 Type A alarms shall not alarm when tested in accor-

dance with 6.3. For alarms with variable sensitivity, the setting shall be set at the most sensitive, according to manufacturer’s instructions.

5.3 Type B, Subsurface Alarm:

5.3.1 Type B alarms shall provide for the automatic sound

of the alarm when tested in accordance with 6.1. For alarms with variable sensitivity, the setting shall be set at the least sensitive, according to manufacturer’s instructions.

5.3.2 Type B alarms shall not alarm when tested in accor-

dance with 6.3. For alarms with variable sensitivity, the setting shall be set at the most sensitive, according to manufacturer’s instructions.

5.4 Type C, Pool Perimeter Alarm:

5.4.1 Type C alarms shall provide for the automatic sound

of the alarm when tested in accordance with 6.4, according to manufacturer’s instructions.

5.4.2 Type C alarms shall not alarm when tested in accor-

dance with 6.5, according to manufacturer’s instructions.

5.5 Type D, Personal Immersion Alarm:

5.5.1 Type D alarms shall provide for the automatic sound

of the alarm when tested in accordance with 6.6, according to manufacturer’s instructions.

5.5.2 Type D alarms shall have a key-locking device to

prevent the removal of the device from the child.

6. Test Procedures

6.1 The test for a child intrusion shall be comprised of five

(5) separate drop tests, two (2) vertical drop tests, and three (3) horizontal drop tests. The weight of the child intrusion simu-lator (CIS) is 20 6 0.5 lb (9.07 6 0.23 kg) and shall be filled with water. The CIS to meet these criteria shall be a mannequin called Rescue Timmy.3 Rescue Timmy meets the requirements of the National Center(s) for Disease Control4 for a one-year-old child. All testing shall be done in a 16-by-32 ft (4.87-by-

9.75 m) swimming pool with a minimum depth of 36 in. (91 cm). Any pool shape is sufficient as long as the pool measures at some point 16 by 32 ft (4.87 by 9.75 m). During all drop tests, both fans shall be operating as described in 6.3. During all drop tests, the pump and filter shall be on and operating.

6.2 To begin each drop test the pool shall be in a non-

operational state, that is, pump, filter, and fans off for a minimum of 10 min. All drop tests are conducted two times with the second drop test following the completion of the first drop test using the testing sequence A, B, C, as described below.

A. Turn pump, filter, and both fans on for 2 min.

B. Initiate any one of the five (5) the drop tests.

C. Two minutes after initiating the drop test turn pump, filter, and fans off for 10 min, repeat test.

D. Each of the two drop tests shall follow the same sequence

(A, B, C).

6.2.1 Vertical Drop Test:

6.2.1.1 Position of the pool alarm shall be in accordance

with manufacturer’s specifications.

6.2.1.2 All vertical drop tests shall be conducted using a

ramp (see Fig. 1). Material for the ramp shall be 10- to 20-mm thick polytetrafluoroethylene (PTFE) or fluorinated ethylene propylene (FEP), approximately 2 ft (0.6 m) wide and 4 ft (1.2

m) in length. A sheet of polypropylene precision woven mesh that is 12 in. in width and 30 in. in length with 20.3 by 20.3 openings per square inch and a thread diameter of .0173 in.

shall be placed between Rescue Timmy and the ramp to enable Rescue Timmy to slide off the ramp in a consistent manner.5

The ramp shall be located on the 16-ft (4.87-m) side of the pool between the two fans approximately in the middle.

6.2.1.3 Place and secure Rescue Timmy (CIS) on his stom-

ach at the lower end of the ramp with the head even with the end of the ramp for a head-first intrusion. Use a string and sinker to maintain the ramp 6 6 0.5 in. (15 6 1.3 cm) above the water and have the ramp at a 35 6 1° angle. Release Rescue Timmy into the water head first. This test shall be repeated two times (see 6.1).

6.2.1.4 Place and secure Rescue Timmy (CIS) on his back at

the end of the ramp with the feet even with the lower end of the ramp for a feet-first intrusion. Use a string and sinker to maintain the ramp 6 6 0.5 in. (15 6 1.3 cm) above the water

3 The sole source of supply of the apparatus known to the committee at this time is Simulaids, 16 Dixon Ave., P.O. Box 807, Woodstock, NY 12498. If you are aware of alternative suppliers, please provide this information to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee,1 which you may attend.

4 Developed by the National Center for Health Statistics in collaboration with the National Center for Chronic Disease Prevention and Health Promotion.

5 One source of supply for the sheet of polypropylene (part number 9275T3) is McMaster-Carr, 200 Aurora Industrial Parkway, Aurora, OH 44202. If you are aware of alternative suppliers, please provide this information to ASTM Interna-tional Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee,1 which you may attend.