ATTACHMENT B - Aspirators Airway - PRODUCT DESCRIPTSION.docx
DOCX document 170 KB Posted
- Attached to
- 6515--NX EQ Aspirators: Airway (VA-22-00012687)
- Solicitation number
- 36C10G22Q0087
View the file
Other files
| File | Type | Posted |
|---|---|---|
| NX EQ Aspirators Airway Product Description SC 8.11.docx | DOCX document | |
| ATTACHMENT A - Aspirators Airway - PRICE LISTS 8.11.xlsx | XLSX spreadsheet | |
| 36C10G22Q0087_3.docx | DOCX document | |
| 36C10G22Q0087_2.docx | DOCX document | |
| 36C10G22Q0087_1.docx | DOCX document | |
| ATTACHMENT C - Aspirators Airway - CONTRACT ADMINISTRATION.docx | DOCX document | |
| ATTACHMENT D - Aspirators Airway - CONTRACT CLAUSES GB.docx | DOCX document | |
| ATTACHMENT F - NX EQ Aspirators Airway - REPORTING TOOL.xlsx | XLSX spreadsheet | |
| ATTACHMENT A - Aspirators Airway - PRICE LISTS.xlsx | XLSX spreadsheet | |
| ATTACHMENT E - Aspirators Airway- SOLICITATION PROVISIONS.docx | DOCX document | |
| 36C10G22Q0087 Aspirators Airway RFQ.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PRODUCT DESCRIPTION
For
NON-EXPENDABLE EQUIPMENT:
S-SCORT® new-Duet or equal Aspirators: Airway
Prepared By:
Strategic Acquisition Center Department of Veterans Affairs 10300 Spotsylvania Avenue, Suite 400 Fredericksburg, VA 22408
1. SCOPE OF WORK:
The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Aspirators: Airway product line as a candidate for a VA-wide (otherwise referred to as “national”) single Requirements contract award. Aspirators: Airway are used in hospitals on crash carts and in areas that do not have access to the central vacuum system. Portable Aspirators: Airway are used to remove obstructing secretions, blood, or vomitus from a patient's airway to keep air passages to the lungs open and to allow spontaneous or mechanical ventilation. Suctioning can be either oropharyngeal (to prepare for emergency intubation or to remove secretions from the upper airway above the glottis) or tracheal (to remove secretions and to maintain the airway of an intubated patient).
The Contractor must demonstrate the ability to meet all requirements for the solicitation. The objective is to provide Aspirators: Airway to be used by clinicians throughout the VA medical centers and facilities. The period of performance is for one (1) 12-month base period with four (4) twelve-month option periods.
2. REQUIREMENT
This requirement will be IAW FAR clause 52.211-6, “Brand Name or Equal” which requires that the quoter indicate that each product that is being offered as an “equal” product to S-SCORT® new-Duet Aspirators: Airway.
The Government's intent for this Requirements contract is to include all ancillary items to ensure the equipment can function as designed by the OEM and as clinically required. The Government may, at its discretion and through bilateral modification, add or remove items to this contract that are determined to be within scope of the solicited product line, not limited to the original items awarded. Additionally, any discontinued items may be replaced via future contract modification by the replacement part identified by the OEM, so long as the replacement part serves the same clinical purpose and function as the originally awarded item. Furthermore, any new technology that is presented during performance of this contract may be evaluated by the Government for inclusion into the contract, via bilateral modification. This new technology must be determined to be within scope of the original contract.
For each equal product, the offeror must include a description reflecting the salient characteristics (SC) and level of quality that will satisfy the salient physical, functional, or performance characteristics of the equal product(s) specified in the solicitation. The quoter must also clearly identify the item by brand name (if any) and make/model number. Finally, the quoter must include descriptive literature, such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the contracting officer, and clearly describe any modifications it plans to make to a product to make it conform to the solicitation requirements.
| CLIN |
| BRAND |
| PART NUMBER |
| DESCRIPTION |
| BASE YR |
| OY1 |
| OY2 |
| OY3 |
| OY4 |
| 0001 |
| SSCOR |
| AE-6975 |
| SSCOR Duet Flat Back (Model 2314) - portable countertop model (includes Canister, 6’ patient tube, HI-D® suction tip, AC power cord and QuickStart Guide) |
| 150 |
| 150 |
| 150 |
| 150 |
| 150 |
| 0002 |
| SSCOR |
| AE-6976 |
| SSCOR Duet with Retention Bracket (Model 2314B) – portable mountable model (includes Canister, 6’ patient tube, HI-D® suction tip, AC power cord and QuickStart Guide) |
| 150 |
| 150 |
| 150 |
| 150 |
| 150 |
| 0003 |
| SSCOR |
| AHP-3 |
| Standard Panel for Cart mounted DUET (Retention Bracket not included) |
| 150 |
| 150 |
| 150 |
| 150 |
| 150 |
| 0004 |
| SSCOR |
| PHP-1S |
| Premier Panel for Cart mounted DUET (Retention Bracket not included) |
| 150 |
| 150 |
| 150 |
| 150 |
| 150 |
The Department of Veterans Affairs (VA) is seeking vendors who can provide S-SCORT® new-Duet or equal Aspirators: Airway as listed above or equal commodities which meet all of the following salient characteristics. Vendors may quote any product solution or configuration so long as they meet the salient characteristics. Vendors are asked to quote any additional product that may be beneficial. These items must be captured in the vendor’s pricing volume with a quantity of zero (0).
CLIN 0001 and CLIN 0002 apply to the following SC’s:
| SC # |
| SALIENT CHARACTERISTICS |
| METHOD OF EVALUATION |
| SC – Literature Map |
| SC 1 |
| The unit should be portable for intrahospital use. |
| Literature Review |
| SC 2 |
| The unit should be able to provide suction of at least ≥ 400 mm Hg at maximum vacuum settings. |
| Literature Review |
| SC 3 |
| The unit should have an adjustable external vacuum gauge display and LED battery charging status indicator lights. |
| Literature Review |
| SC4 |
| The unit should have a performance/vacuum (air) flow rate of at least ≥ 30 lpm. |
| Literature Review |
| SC 5 |
| The unit should support a disposable collection canister of at least ≥1,000 mL capacity. |
| Literature Review |
| SC 6 |
| The unit should be equipped with an internal automatic battery charger and minimum 100V – 240V AC Electrical Systems. |
| Literature Review |
| SC 7 |
| The unit should be equipped with a battery depletion (bad battery) indicator warning. |
| Literature Review |
| SC 8 |
| Fully charged batteries should power the unit at maximum/full capacity vacuum for ≥30 minutes. |
| Literature Review |
image1.png