This is a Laboratory Report for lead paint analysis conducted by an accredited laboratory for Lepi Enterprises, Inc. on behalf of the Greater Dayton Regional Transit Authority (RTA) in Ohio. The report documents the testing of paint samples from the RTA's maintenance facility using flame atomic absorption spectrophotometry in accordance with USEPA SW846 7000B methodology. Two samples were analyzed, with lab IDs 3949615 and 3949616, received at the laboratory on December 12, 2025, analyzed on December 15, 2025, and reported on December 17, 2025. The samples tested at concentrations of 220 PPM (0.02202% by weight) and 232 PPM (0.02319% by weight) respectively.
The results indicate that both samples exceed the Consumer Products Safety Standard threshold of 0.009% lead by weight and fall below the Federal Lead Standard/HUD regulatory limit of 0.5% lead by weight. The analysis was performed by AIHA LAP accredited laboratory 290960 located in Fort Mill, South Carolina, with a minimum reporting limit of 13.7 micrograms of total lead. This lead paint testing documentation supports the scope of work for the RTA's Maintenance Facility Painting Project by establishing baseline conditions and identifying lead-based paint presence that must be addressed during preparation and painting operations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Maintenance_Facility_Painting_Project.pdf | ||
| Attachment_A_–_Facility_Drawings_with_wall_height.pdf | ||
| Sample_Contract_(DO_NOT_COMPLETE).pdf | ||
| RTA_General_Terms_and_Conditions.docx | DOCX document | |
| RTA_Construction_Terms_and_Conditions.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLIENT PROJECT:
LAB CODE:
December 17, 2025
Melissa Colvin Lepi Enterprises, Inc.
630 G. W. Morse Street Zanesville, OH 43701
26 114, Greater Dayton RTA 711482-1
Dear Melissa, Enclosed are lead analysis results for chemistry samples received at our laboratory on December 12, 2025. The samples were analyzed for lead using flame atomic absorption spectrophotometry.
Thank you for your business and we look forward to continuing good relations.
Kind Regards, Kamila Reichert, Laboratory Director
AIHA LAP 290960
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146
LABORATORY REPORT
By: Flame Atomic Absorption Spectrophotometry
Prepared for
Lepi Enterprises, Inc.
CLIENT PROJECT: 26 114, Greater Dayton RTA
LAB CODE: 711482-1
TEST METHOD: USEPA SW846 7000B (LEAD IN PAINT)
REPORT DATE: 12/17/25
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146
ConcentrationConcentrationConcentrationConcentration Client IDClient IDClient IDClient ID Lab IDLab IDLab IDLab ID PPM (µg/g)PPM (µg/g)PPM (µg/g)PPM (µg/g) % By Weight% By Weight% By Weight% By Weight
26-114-126-114-126-114-126-114-1 3949615 220 0.022020.022020.022020.02202
26-114-226-114-226-114-226-114-2 3949616 232 0.023190.023190.023190.02319
Client: Lepi Enterprises, Inc.
630 G. W. Morse Street Zanesville, OH 43701
Project:
Method:
LABORATORY REPORT
By: Flame Atomic Absorption
Spectrophotometry
711482-1 12/12/25 12/15/25 12/17/25
Lab Code:
Date Received:
Date Analyzed:
Date Reported:
26 114, Greater Dayton RTA
USEPA SW846 7000B (LEAD IN PAINT)
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146 Page 1 of 2
LEGEND:LEGEND:LEGEND:LEGEND: µg = microgram, ppm = parts per million, g = grams, ml = milliliter, Pb = lead, wt = weight, BRL = Below Reporting Limit
METHOD:METHOD:METHOD:METHOD: USEPA SW846 7000B (LEAD IN PAINT)
REGULATORY LIMIT:REGULATORY LIMIT:REGULATORY LIMIT:REGULATORY LIMIT: OSHA Standard: No safe limit. Consumer Products Safety Standard: Greater than 0.009% lead by weight. Federal Lead Standard / HUD: 0.5% lead by weight.
This method has been validated for sample weights of 0.25g or greater. When samples with a weight of less than thatThis method has been validated for sample weights of 0.25g or greater. When samples with a weight of less than thatThis method has been validated for sample weights of 0.25g or greater. When samples with a weight of less than thatThis method has been validated for sample weights of 0.25g or greater. When samples with a weight of less than that are analyzed those results fall outside of the scope of accreditations.are analyzed those results fall outside of the scope of accreditations.are analyzed those results fall outside of the scope of accreditations.are analyzed those results fall outside of the scope of accreditations.
* The analysis of composite wipe samples as a single samples is not included under AIHA LAP, LLC accreditation.* The analysis of composite wipe samples as a single samples is not included under AIHA LAP, LLC accreditation.* The analysis of composite wipe samples as a single samples is not included under AIHA LAP, LLC accreditation.* The analysis of composite wipe samples as a single samples is not included under AIHA LAP, LLC accreditation.
Minimum reporting limit is 13.7 µg total lead. Sample results denoted with a “less than” (<) sign contain less than 13.7 µg total lead, based on a 50ml sample volume.
Lead samples are analyzed by Eurofins Built Environment Testing East, LLC, an AIHA LAP, LLC ELLAP accredited laboratory (AIHA Lab ID: LAP-290960) for lead analysis of air, soil, wipes, and paint samples.
Laboratory results represent the analysis of samples as submitted by the client. Information regarding sample location, description, area, volume, etc., was provided by the client. Unless notified in writing to return samples, Eurofins Built Environment Testing East, LLC discards client samples after 30 days. This report shall not be reproduced, except in full, without the written consent of Eurofins Built Environment Testing East, LLC.
Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.
L01L01L01L01 - Insufficient sample weight L02L02L02L02 - Endcaps missing; possible cross contamination or sample loss L03L03L03L03 - Sample weight below protocol guidelines L04L04L04L04 - Sample contains substrate, potentially affecting results L05L05L05L05 - Sample weight below protocol guidelines and contains substrate, potentially affecting results
Brenda Ibarra Analyst
DATA QA:
Raegan Brown 12/17/2025
APPROVED BY:
Kamila Reichert, Laboratory Director
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146 Page 2 of 2
SUBMITTED BY INVOICE TO
Client Sample ID Number
RES Job #: 711482
CONTACT INFORMATION SERIES
ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
CHEMISTRY LABORATORY
MICROBIOLOGY LABORATORY
**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**
Laboratory Analysis Instructions
(Sample ID's must be unique)
Company: Lepi Enterprises, Inc. Company: Lepi Enterprises, Inc.
Address: 630 G. W. Morse Street Address: 630 G. W. Morse Street
Zanesville, OH 43701 Zanesville, OH 43701
Project Number and/or P.O. #: 26 114 Project Zip Code:
Project Description/Location: Greater Dayton RTA
Contact: Melissa Colvin -1 PLM Standard 3 Phone: (740) 453-2980
Fax:
Cell:
Final Data Deliverable Email Address:
reception@lepienterprises.com
PLM / PCM / TEM / NYS DTL RUSH PRIORITY STANDARD Air = A Bulk = B OH
Dust = D Food = F
Paint = P Soil = S
Dust RUSH PRIORITY STANDARD
*PRIOR NOTICE REQUIRED FOR SAME DAY TAT
Surface = SU Swab = SW
Tape = T Wipe = W
Metals RUSH PRIORITY STANDARD Drinking Water = DW
Waste Water = WW
Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**
Viable Analysis** PRIORITY STANDARD
**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH
Medical Device Analysis RUSH STANDARD
Mold Analysis RUSH PRIORITY STANDARD
Special Instructions:
ASBESTOS CHEMISTRY MICROBIOLOGY ICO
1 26-114-1 X X P
2 26-114-2 X X P P
L M
T E
M
P C
M
N Y
S
D U
S T
M E
TA
L
S
A n al yt e( s)
L ea d b y
F la m e
A A
(U S
E
PA
S W
6)
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Built Environment Testing East, LLC establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.
Eurofins Built Environment Testing East, LLC will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET30. Failure to comply with payment terms may result in a 18% APR finance charge.
Relinquished By:
Date/Time: 12/12/2025 13:32:01 Sample Condition: Acceptable
Received By:
Olivia Zlotnicki Date/Time: 12/12/2025 15:42:14 Carrier: Fed-Ex
Eurofins Built Environment Testing East, LLC Effective
(919) 481-1413 https://www.eurofinsus.com/builtenv730 SE Maynard Rd, Cary, NC 27511
File details come from the government source that posted it. Updated .