Attachment_A_-_Specifications.pdf

PDF 111 KB Posted

Attached to
P24-1435R
Solicitation number
P24-1435R
Issued by
Orange County, California

About this file

This document appears to be a technical specification sheet for two scientific instruments: an Automatic Freezepoint Detection System and a Thermo Scientific Dionex Inuvion Ion Chromatograph (IC) system. The Automatic Freezepoint system is a benchtop unit with a temperature range of +55 to -95°C, offering precise freezing point measurement with 0.06°C resolution and ±0.1°C accuracy. It features a direct cooling system, integrated touch screen panel PC, and can perform up to 60,000 analyses with Microsoft Excel compatible file output. The system complies with ASTM D1177 standards and includes safety features like audible alarms and error messaging.

The Thermo Scientific Dionex Inuvion IC system is a high-pressure ion chromatograph specifically designed to analyze chlorides in coolants. It includes an integrated vacuum degas for eluent degassing, supports electrolytic suppression, and features a chemically inert, metal-free PEEK flow path. The system has a high-pressure tolerance of 0-35 MPa, includes a conductivity detector with thermal control, and can output ranges up to 18,000 μS/cm. The package comes with additional accessories such as an autosampler, suppressor, guard column, eluent concentrate, operating software, a starter kit with consumables, and on-site installation.

View the file

Other files

File Type Posted
P24-1435_RFQ_SB_OPTION.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Automatic Freezepoint:

Temperature Range: +55 to -95°C

Resolution: 0.06°C

Accuracy: ±0.1°C

Repeatability / Reproducibility: as per standard test methods or better

Data Storage: 60,000 analyses

• stand alone system with Integrated Touch Screen Panel PC

• Direct Cooling system eliminates the need for solvent cooling baths

• One-stage cooling system provides temperatures as low as -45°C and a two-stage cooling system down to -80°C

• Freezing Point measured by light pulsed emission on IR spectrum through a coaxial fiber optic with mirror

• Safety Features: Audible alarm and displayed messages (at the end of the analysis and in case of errors and/or malfunctions)

• Pressure controller for 1st and 2nd stage motor compressor

• Thermostat for 2nd stage activation

• Thermo-switch for each cooling / heating jacket

• Motor compressors equipped with internal overload devices

115V 60 Hz

The freezing point detection system provides automated sample testing with accuracy and repeatability in accordance with ASTM D1177. The sample is cooled in the test chamber with constant stirring.

Benchtop unit

Solvent Free

Platinum resistance PT100 Class A temperature probe.

Direct cooling system features integrated gas CFC free motors compressors thus eliminating the need for a solvent cooling bath.

The direct system is capable of rapid cooling, approaching -80°C bath.

Microsoft® Excel compatible file format

22185-60108 Thermo Scientific Dionex Inuvion IC system

High-pressure ion chromatograph with eluent degas and support for electrolytic suppression with RFIC

• The Instrument will be used to analyze Chlorides in Coolants.

• Integrated vacuum degas for in-line degassing of eluents

• Control and support for Reagent-Free Electrolytically Regenerated

Suppression and continuously regenerated chemical suppression

All Inuvion IC systems provide the following:

• Chemically inert, metal-free PEEK flow path

• High-pressure tolerant system (0-35 MPa)

• Support for continuously regenerated chemical suppression

• Serial dual-reciprocating piston pump

• 6-port, 2-position injection valve

• Conductivity detector and cell with thermal control and output range up to 18,000 μS/cm

• Eluent shut-off valve

• Leak sensor

• Easily configurable with a number of optional accessories to improve performance and increase

• Autosampler

• Suppressor for Chlorides Column for Chlorides Guard column

• Eluent concentrate

• Operating software for instrument

• Starter kit with IC consumables, tubing, seals, etc.

• Installation on-site

Automatic Freezepoint:

File details come from the government source that posted it. Updated .