Attachment A_Site Secuirty Fence Map.pdf

PDF 4 MB Posted

Attached to
Fence Replacement-U. S. Embassy Cabo Verde Federal contract opportunity
Solicitation number
19GE5022R0037_1
Issued by
Department of State Office of Acquisition Management

View the file

Other files for this federal contract opportunity

Other files attached to Fence Replacement-U. S. Embassy Cabo Verde, newest first.
File Type Posted
Praia_NEC_Exterior Lighting Schedule EX-1 and EX-2.pdf PDF
19GE5022R0037_0003.pdf PDF
Praia_NEC_Construction Fencing_Site Photos.docx DOCX document
Praia_NEC_City Plat Map.pdf PDF
19GE5022R0037 Question and Answers.pdf PDF
Praia_NEC_Site Map with Utilities.pdf PDF
19GE5022R0037 0002.pdf PDF
Attachment D_Location of Gates and Guard Structure.pdf PDF
J.2.4 Form W-14.pdf PDF
J.2.3COR Questionnaire for TCNs.pdf PDF
Attachment B_Fence Diagram.pdf PDF
J.2.1 Performance Guaranty Sample.docx DOCX document
19GE5022R0037_Final.pdf PDF
J.2.2 Payment Guaranty Sample.docx DOCX document
Attachment C_ Example Light Structure.pdf PDF
J.2.5 Sample Breakdown of Price Proposal.xls XLS spreadsheet
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PRAIA NEC DD REPORT | OBO PROJECT NO. 19AQMM20F1088 | UNCLASSIFIED 53

NORTH

TENNIS COURT 1

TENNIS COURT 2

TENNIS COURT 3

Avenida C idade de Lisboa

Rua Conego Ja cin to

FIELD 1

FIELD 2

Rua Conego Ja cin to

Rua Conego Jacinto

Avenida da China

Avenida da China

Avenida da China Avenida da China

Avenida C idade de Lisboa

BLOCK 1 - C

oncre te Block

1° fl oor: l eve l 5

.51 m

2° F loor: l eve l 8

.71 m

UNUSED

TOILET

level: 4.28m

Rotunda Homen de Pedra

Avenida de Cuba

4.72

5.11

3.07

Rua do Beco

Rua do Jardin

ST

ST

ST

ST

ST

E

E

C

S S

R

R

R

R

D

BLOCK 2 - C

oncre te Block

1° fl oor: l eve l 5

.54 m

2° F loor: l eve l 8

.73 m

BLOCK 1 - C

oncre te Block

1° fl oor: l eve l 5

.49 m

2° F loor: l eve l 8

.70 m

Storage House

Concrete block

1 floor level 5.72 m

BLOCK 4 - Concrete Block

1 floor

Level 5.52 m

Hou se in st on e

1 f loo r lev el

.53 m

BLOCK 1 - C

oncre te Block

1° fl oor: l eve l 5

.49 m

2° F loor: l eve l 8

.70 m

CAFETERIA

1 level: 4 .70 m

CAFETERIA

1 level: 4 .70 m

BLOCK 4 - Concrete Block

1 floor

Level 5.52 m

ADMINISTRATION - Concrete Block

1 floor

Level 4.73 m

Closed House

Concrete block

1 floor

Guardian house

Concre te Block

4.50

8.

8.

4.25 3.75

3.50 3.25

4.504.50

3.50

3.50

3.50 3.50

3.50

3.25 3.25

3.25

3.75

Scale in meters 1:500

COORDINATE SYSTEM LAMBERT (EPSG 4826)

0 2 4 6 8 10 20 30m

JCC2020-ST279NEW EMBASSY COMPOUND

PRAIA - CAPE VERDE

ST279-03

SURVEY PLAN NOTES:

REVISIONS DESCRIPTION DATE

Project No.

Date

Drawn By

Checked By

Project

Drawing Title

Scale

Drawing No.

Sheet 1 of 4

LEGEND (NOT SHOWN TO SCALE)

CCTV

DOOR

POLE-ELECTRIC

DOUBLE DOOR

MANHOLE UNKNOWN-CONCRETE

POLE-TELEPHONIC

SEPTIC-TANK

TREE - NAME AND SIZE cm

ELECTRIC BOXE

SPOT ELEVATION

LANDSCAPED AREALSAST ST

3.23

POLE-STREET LAMP

MANHOLE UNKNOWN-IRON

MANHOLE COMMUNICATIONC C

MANHOLE DRINKING WATER

MANHOLE STORM WATER

ADVERTISING PLAQUE

HYDRAULIC-WORK

SLOPE-TOP

SLOPE-BASE

STORM-WATER-DRAIN

COMMUNICATION LINETRANSFORMER-STATION

CURB

MANHOLE SEWERS S

H H

RESERVOIRR R

CONTOURS

D D

T TTS

ELECTRIC AERIAL LINEE E

ELECTRIC UNDERGROUND MT LINEEU EU

FENCEx x

HOUSE / BUILDING

HOUSE-BOOTH

HOUSE-RUINS

BALCONY

ROAD-ASPHALT

ROAD-STONE

WALL BLOCK

WALL CONCRETE

WALL STONE

BOUNDARY LINE

STORM-WATER-NETWORK +SIZE mmSW500

SEWERAGE NETWORK + SIZE mm

DRINKING-WATER-NETWORK +SIZE mm90 90

S500

1. THIS SURVEY IS BASED UPON EXISTING PHYSICAL CONDITIONS FOUND AT THE SUBJECT SITE, AND THE FOLLOWING LOCAL PROVIDED

REFERENCES:

1.1 A COPY OF THE OFFICIAL LOCATION PLANS OF THE THREE PARCELS HAS BEEN PROVIDED BY LANGAN IN APRIL 2020 PERIODS.

1.2 PLAN "SITE UTILITY" FOR WATER AND SANITATION HAS BEEN PROVIDED BY LANGAN IN JUNE 2020 PERIODS.

2. THIS SURVEY ("X", "Y" AND "Z") IS REFERENCED TO THE SYSTEM WGS84 CAPE VERDE NATIONAL PROJECTION LAMBERT EPSG 4826 DERIVED USING EXISTING GEODESIC MONUMENTS "MONTE VERMELHO" AND "AGOSTINHO ALVES" PER THE NATIONAL INSTITUTE.

3. STREET NAMES ARE SHOWN IN ACCORDANCE WITH THE CITY GIS MAPS.

4. TOPOGRAPHIC INFORMATION SHOWN HEREIN HAS BEEN OBTAINED FROM GROUND SURVEYS BY "JCC ESTUDOS E TOPOGRAFIA" DURING MAY

AND JUNE 2020 PERIODS.

5. BOUNDARY SURVEY INFORMATION SHOWN WAS PREPARED AND PROVIDED BY "JCC ESTUDOS E TOPOGRAFIA" IN JUNE 2020 PERIODS.

6. UNLESS SPECIFICALLY NOTED HEREON, STORM AND SANITARY SEWER INFORMATION WAS OBSERVED AND MEASURED AT FIELD LOCATED STRUCTURES (MANHOLES/CATCH BASINS, ETC ). CONDITIONS CAN VARY FROM THOSE ENCOUNTERED AT THE TIMES WHEN DATA WAS OBTAINED. DESPITE MEETING THE REQUIRED STANDARD OF CARE THE SURVEYOR CANNOT AND DOES NOT WARRANT THAT PIPE MATERIAL AND/OR PIPE SIZE THROUGHOUT THE PIPE RUN ARE THE SAME AS THOSE OBSERVED AT EACH STRUCTURE, OR THAT THE PIPE RUN IS STRAIGHT

BETWEEN THE LOCATED STRUCTURES.

7. ADDITIONAL UTILITY (WATER, ELECTRIC AND TELECOMMUNICATIONS) DATA MAY BE SHOWN FROM FIELD LOCATED SURFACE MARKINGS (BY OTHERS), EXISTING STRUCTURES, AND/OR FROM EXISTING DRAWINGS AND USED TO COMPILE SUBSURFACE UTILITY INFORMATION SHOWN

HEREON .

8. UNLESS SPECIFICALLY NOTED HEREON THE SURVEYOR HAS NOT EXCAVATED TO PHYSICALLY LOCATE THE UNDERGROUND UTILITIES. THE SURVEYOR MAKES NO GUARANTEES THAT THE SHOWN UNDERGROUND UTILITIES ARE EITHER IN SERVICE, ABANDONED OR SUITABLE FOR

USE, NOR ARE IN THE EXACT LOCATION OR CONFIGURATION INDICATED HEREON.

9. PRIOR TO ANY DESIGN OR CONSTRUCTION THE PROPER UTILITY AGENCIES MUST BE CONTACTED FOR VERIFICATION OF UTILITY TYPE AND FOR

FIELD LOCATIONS.

10. All CURBS ON-SITE AND OFF-SITE ARE CONCRETE.

11. TREES SPECIES SYMBOLS AND DESCRIPTION CAN BE FOUND IN THE FINAL SURVEY REPORT.

3,000 mm

3, m m

3,000 mm

3,000 m m

Trees that must be preserved

3 meter clear zone

New Security Fence

Fence at Property Line

SITE SECURITY FENCE

4/11/2022

DRAFT

NOT FOR CONSTRUCTION

3,000 m m

File details come from the government source that posted it. Updated .