These documents are engineering and construction plans for a Canopy Replacement Project at a Re-Pump Station for the Seminole Tribe of Florida, located at 32051 W Boundary Rd, Clewiston, FL 33440. The project involves replacing the existing canopies at a re-pump station with two new identical canopy structures, each measuring 30' x 25' with concrete foundations. The project includes removing existing infrastructure such as canopies, support poles, containers, and electrical systems, and installing new cold-formed steel canopy structures with electrical and lighting improvements.
The project is designed according to the Florida Building Code (FBC) 2023, with wind speed specifications of 150 MPH and risk category II. The structural design includes concrete footings with pedestals, electrical upgrades including new lighting and receptacles, and comprehensive grounding and lightning protection systems. The canopy structures will feature moment frames, roof purlins, and are engineered to withstand specific wind loads and seismic design requirements. The plans were prepared by HSQ Group, LLC and Alliance Engineering, with detailed specifications for electrical systems, foundation design, and temporary bracing during construction.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment G - Sample Contract.pdf | ||
| Attachment D - Environmental Compliance Review.PDF | ||
| Attachment E - Canopy Calculations.pdf | ||
| Attachment F - Steel Commander Plans.pdf | ||
| Exhibit C - Statement of Qualifications.xlsx | XLSX spreadsheet | |
| RFP 62-2025.pdf | ||
| Exhibit A - Proposal Form.xlsx | XLSX spreadsheet | |
| Attachment C - Geotechnical Report.pdf | ||
| Exhibit P - W-9 Form.pdf | ||
| Attachment B - Specification Book.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Zachary D Todd
Digitally signed by Zachary D Todd DN: c=US, o=Unaffiliated, dnQualifier=A01410D000
00196D04F8EAE00090F3
D, cn=Zachary D Todd Date: 2025.08.15 13:49:41 -04'00'
ATTACHMENT A
ELECTRICAL GENERAL NOTES
1. THE SCOPE OF WORK SHALL CONSIST PRIMARILY OF THE FOLLOWING:
1.1. PROVIDE AND INSTALL NEW LIGHTING AND ELECTRICAL DISTRIBUTION SYSTEMS, AS SHOWN ON PLANS, FOR A COMPLETE
WORKING SYSTEM IN PLACE.
2. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS AND LABOR TO INSTALL THE ELECTRICAL SYSTEMS AS INDICATED ON THE DRAWINGS. ITEMS NOT SHOWN BUT OBVIOUSLY NECESSARY FOR COMPLETION OF THE WORK SHALL BE INCLUDED.
3. THE INSTALLATION SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, LOCAL CODES AND FLORIDA BUILDING
CODE.
4. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS, INSPECTIONS AND APPROVALS AND INCLUDE ALL FEES AS PART OF
THEIR BID IF NOT OTHERWISE NOTED.
5. THE CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE ENGINEER AND OWNER.
6. THE CONTRACTOR SHALL VISIT THE SITE OF THE PROJECT AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS. NO ALLOWANCE WILL BE MADE FOR EXISTING CONDITIONS OR FAILURE OF THE CONTRACTOR TO OBSERVE THEM.
7. CONTRACTOR SHALL NOTIFY OWNER 72 HOURS IN ADVANCE OF ANY WORK THAT REQUIRES A POWER SHUTDOWN, IN ORDER TO GET THE AUTHORIZATION TO COMMENCE THE WORK. CONTRACTOR SHALL PROVIDE A WORKING SCHEDULE IN WRITING TO
OWNER SHOWING THE PROPOSED SCHEDULE OF WORK WITH THE ANTICIPATED TIME DURATIONS.
8. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH ALL LOCAL UTILITIES, INCLUDING THE POWER AND COMMUNICATION UTILITIES TO MEET ALL OF THEIR INSTALLATION REQUIREMENTS. ALL LABOR, EQUIPMENT OR MATERIALS NECESSARY TO MEET THESE REQUIREMENTS ARE TO BE INCLUDED IN THE BID. THE CONTRACTOR SHALL OBTAIN, DELIVER AND INSTALL ALL CONDUITS, PULL-BOXES AND EQUIPMENT AS REQUIRED BY THE UTILITIES TO MEET THEIR SPECIFICATIONS.
9. ALL EQUIPMENT AND MATERIAL SHALL BE UNUSED AND U.L. LISTED. ALL REFERENCES TO A PARTICULAR MANUFACTURER ARE
GIVEN ON AN "APPROVED ALTERNATE" BASIS.
10. THE CONTRACTOR IS RESPONSIBLE TO TEST ALL SYSTEMS INSTALLED OR MODIFIED UNDER THIS PROJECT AND REPAIR OR
REPLACE ALL DEFECTIVE WORK TO THE SATISFACTION OF THE ENGINEER AND OWNER.
11. ALL EQUIPMENT FURNISHED AND INSTALLED BY THE CONTRACTOR UNLESS OTHERWISE NOTED IN THE SPECIFICATIONS SHALL BE GUARANTEED AGAINST DEFECTS IN MATERIAL AND WORK PRODUCT FOR A PERIOD OF ONE YEAR FROM DATE OF
SUBSTANTIAL COMPLETION.
12. ALL CONDUCTORS SHALL BE COPPER. NO ALUMINUM ALLOWED UNLESS SPECIFICALLY INDICATED ON DRAWINGS. SEE
SPECIFICATIONS FOR ADDITIONAL INFORMATION ON CONDUCTORS.
13. SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL ELECTRICAL AND SPECIAL SYSTEMS EQUIPMENT AND MATERIAL.
14. ALL CONTROL PANELS SHALL BE CONSTRUCTED UNDER UL 508A STANDARD, BY A APPROVED PANEL VENDOR AND THE VENDOR
SHALL BEAR A UL 508A LABEL ON THE PANEL.
15. THE DRAWINGS ARE NOT INTENDED TO SHOW THE EXACT LOCATION OF CONDUIT RUNS. THESE ARE TO BE COORDINATED WITH
THE OTHER TRADES SO THAT CONFLICTS ARE AVOIDED PRIOR TO INSTALLATIONS.
16. ALL LOCATIONS OF EQUIPMENT, PANELS ETC. ARE SHOWN FOR ILLUSTRATION PURPOSES. CONTRACTOR SHALL VERIFY AND COORDINATE EXACT LOCATION AND SIZE WITH ALL SUBCONTRACTORS AND EQUIPMENT SUPPLIERS PRIOR TO ANY
INSTALLATION AND THEN INSTALL AS SUCH WITH CORRESPONDING CONDUIT STUB-UPS.
17. SEE OTHER DISCIPLINE DRAWINGS FOR COORDINATION OF ALL DRAWINGS. ANY CONFLICTS SHALL BE BROUGHT TO THE CONSULTANT'S ATTENTION AND MOVEMENT OF CONDUITS OR OTHER ELECTRICAL EQUIPMENT SHALL BE ACCOMPLISHED
WITHOUT ANY ADDITIONAL COST FOR THE OWNER.
18. LOCATIONS OF HANDHOLES AND PULL BOXES ARE APPROXIMATE. CONTRACTOR SHALL COORDINATE EXACT LOCATION WITH
EXISTING AND NEW PIPING OR CONDUIT AND ADJUST ACCORDINGLY.
19. NOT ALL CONDUITS SHOWN ON RISER AND ONE-LINE DIAGRAMS ARE SHOWN ON THE SITE PLANS. CONTRACTOR SHALL SUPPLY
ALL CONDUITS AND CABLES AS SHOWN ON RISERS, DETAILS, AND ONE-LINE DIAGRAMS.
20. ALL CIRCUITS SHALL BE IDENTIFIED IN JUNCTION BOXES, PULL BOXES, CONTROL PANELS, PANELBOARDS, LIGHTING POLES, CONTROLLERS AND SERVICE POINTS. IDENTIFICATION SHALL MATCH PANELBOARD SCHEDULES.
21. CONDUCTOR PULLING TENSIONS SHALL NOT EXCEED MANUFACTURER'S RECOMMENDATION. CONTRACTOR SHALL INSTALL PULL
BOXES TO MEET MANUFACTURER'S REQUIREMENTS.
22. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONDUIT AND WIRING INSTALLATION FOR ALL VENDOR PROVIDED EQUIPMENT (PACKAGE SYSTEMS). IF THE SHOP DRAWINGS DIFFER FROM THE DESIGNED FACILITIES, THE CONTRACTOR SHALL REDESIGN THE FACILITIES AND SUBMIT THE REVISED DESIGN FOR THE CONSULTANT'S APPROVAL ALONG WITH THE SHOP DRAWINGS. THERE SHALL BE NO ADDITIONAL COST TO THE OWNER FOR THE REDESIGN NOR FOR ANY ADDITIONAL CONDUITS AND WIRING. DURING SUBMITTAL THE CONTRACTOR SHALL VERIFY ALL SUPPLIED BREAKER SIZES FOR ALL PACKAGED SYSTEMS AND MODIFY ALL BREAKERS IN PANELBOARDS ACCORDINGLY WITHOUT ANY ADDITIONAL COST TO THE OWNER.
23. GROUNDING SHALL BE INSTALLED IN ACCORDANCE WITH NEC, ARTICLE 250. THE GROUNDING SYSTEM TEST SHALL NOT EXCEED A 48 HOUR SPAN DRY RESISTANCE OF 25 OHMS. ADDITIONAL GROUNDING TO MEET THIS REQUIREMENT SHALL BE INSTALLED AT NO EXTRA COST. GROUNDING AND BONDING CONNECTIONS SHALL NOT BE PAINTED. ALL GROUNDING CONNECTIONS SHALL BE
EXOTHERMIC UNLESS SPECIFICALLY INDICATED OTHERWISE.
24. AN EQUIPMENT GROUND WIRE SIZED PER NEC SHALL BE PULLED IN ALL ELECTRICAL CONDUITS, POWER AND CONTROL, WHETHER OR NOT INDICATED ON THE PLANS.
25. ALL ENCLOSURES, TJB, WIREWAY, PULL BOXES ETC. SHALL CONTAIN A GROUNDING BUS. CONNECT ALL RACEWAY BONDS TO THIS BUS VIA GROUNDING BUSHING AND EXTEND BONDING JUMPER FROM THIS BUS TO THE ENCLOSURE.
26. PROVIDE CONDUIT DUCT SEAL AT ALL CONDUIT ENDS.
27. ALL SPARE CONDUITS SHALL BE SEALED WITH A CAP AT BOTH ENDS AND A PULL STRING INSTALLED WITH IDENTIFICATION ON
BOTH ENDS.
28. TYPEWRITTEN PANEL SCHEDULES SHALL BE INSTALLED IN EACH PANELBOARD, AND TYPEWRITTEN TERMINAL BLOCK
SCHEDULES IN EACH CONTROL CABINET.
29. CONTRACTOR SHALL BALANCE PANELBOARD LOADS AT THE END OF THE PROJECT.
30. ALL EXPOSED CONDUITS IN NON-AIR CONDITIONED AREAS SHALL BE RMC. ALL UNDERGROUND CONDUITS SHALL BE PVC
SCHEDULE 40 UNLESS OTHERWISE NOTED.
31. COMBINING OF NEUTRAL CONDUCTORS SHALL NOT BE ALLOWED.
32. THE CONTRACTOR MAY COMBINE CONDUCTORS TO LIMIT THE NUMBER OF CONDUITS LEAVING THE PANELBOARD. CONTRACTOR SHALL DERATE THE WIRES AS PER NEC AND INCREASE THE SIZE OF THE WIRES ACCORDINGLY.
33. FOR CABLE COLOR CODE PLEASE REFER TO SPECIFICATION 260519.
34. CONTRACTOR SHALL PROVIDE TO THE COUNTY WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE RECORD DRAWINGS DEPICTING THE COMPLETED INSTALLATION AS INSTALLED INCLUDING A SINGLE LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION AND FLOOR PLANS INDICATING THE LOCATION AND AREA SERVED BY ALL INSTALLED DISTRIBUTIONS PER THE
FLORIDA BUILDING CODE, DIVISION C405.7.4.1.
35. CONTRACTOR SHALL PROVIDE TO THE COUNTY OPERATING AND MAINTENANCE MANUALS (O&M MANUALS) FOR ALL EQUIPMENT
PER THE FLORIDA BUILDING CODE, DIVISION C405.7.4.2. THE MANUALS SHALL INCLUDE:
35.1. SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING
MAINTENANCE.
35.2. O&M MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONS
SHALL BE CLEARLY IDENTIFIED.
35.3. NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY
36. BRANCH AND FEEDER CONDUCTORS ARE SIZED FOR MAXIMUM VOLTAGE DROP OF 5 PERCENT COMBINED AT DESIGN LOAD PER
THE FLORIDA BUILDING CODE-ENERGY CONSERVATION-C405.5.3.
37. ALL REFERENCES TO SS OR STAINLESS STEEL SHALL MEAN 316 STAINLESS STEEL.
38. ALL ELECTRICAL EQUIPMENT SHALL BE PERMANENTLY IDENTIFIED AND SIGNED PER THE REQUIREMENTS OF THE NEC AND THE
FLORIDA BUILDING CODE.
39. MINIMUM DISTANCE ALLOWED BETWEEN POWER CONDUITS AND INSTRUMENTATION/COMMUNICATION CONDUITS SHALL BE:
VOLTAGE DISTANCE
480V 2 FT
120V 1 FT
40. CONTRACTOR SHALL RESTORE SIDEWALKS, PARKING LOTS, ROADWAYS, SOD AND SPRINKLER SYSTEM TO MATCH EXISTING, AFTER THE COMPLETION OF WORK.
EL
EC
TR
IC
AL
G
EN
ER
AL
N
O
TE
S
E-1
PROJ
DATE
D
RR
EV
IS
IO
N
C H
K
BY
AP
VD
SHEET
DWG
1 2 3 4 5 6
A
B
C
D
EN
G
R
SE
AL
C O
M M
U N
IT
Y
PL
AN
N
IN
G
D
EV
EL
O
PM
EN
T
SE
M
IN
O
LE
T R
IB
E
O F
FL
O
R
ID
A
G
R
IF
FI
N
R D
D
AV
IE
, F L
PH
(9
) 9
-6
D
AT
E N
O
Know what's
R
Call before you dig.
below.
N/A
SEMINOLE TRIBE OF FLORIDA
PUBLIC WORKS DEPARTMENT
CONTACT TWO (2) BUSINESS DAYS BEFORE DIGGING
HTTP://TED.SEMTRIBE.COM/FORMS-LIBRARY
DIGPUBLICWORKS@SEMTRIBE.COM
(954) 894-1060 - EXT. 10910
07/25
B
IG
C Y
P R
E S
S R
E -P
U M
P S
T A
T
IO
N
JW
K
JW
K
AL
C
JW
K
2403-31
JAMES W. KAPPES
FL P.E. NO. 71499
HSQ GROUP, LLC.Engineers · Planners · Surveyors4577 N Nob Hill Road, Suite 210Sunrise, Florida 33351 · 954.440.6990
C26258 · LB7924
H S
Q G
R O
U P
, I N
C
En gi ne er s
· P la nn er s
· S ur ve yo rs
N ob H ill R oa d, S ui te
Su nr is e, F lo rid a
· 9
.4
.6
C
· L
B7
ONE LINE DIAGRAMS, RISER DIAGRAMS AND SCHEMATICS
EXISTING
LINE WEIGHT
NEW
NOTE:
ELECTRICAL PLAN/LAYOUT
DEMOLITION TO BE REMOVED, MODIFIED OR DELETED
THIS IS A STANDARD LEGEND SHEET. SOME SYMBOLS OR ABBREVIATIONS MAY APPEAR ON THIS SHEET
AND NOT BE UTILIZED ON PROJECT. SYMBOLS ARE NOT TO SCALE.
SPD SURGE PROTECTIVE DEVICE
EMS
SIGNAL MAINTENANCE ACCESS HOLESMH
DESCRIPTION
ABBREVIATIONS
ABBV.
NEUTRAL
MINIMUM
MH
N
NC
MS
NEMA
MDP
MIN
MDS
DISCONNECT SWITCH
MAIN DISTRIBUTION PANEL
MOTOR STARTER
NATIONAL ELECTRIC
NORMALLY CLOSED
MAINTENANCE ACCESS HOLE
MAIN SERVICE
ON-OFF
NP
OC
NO
OL
OO
OCR
OOA
NTS
OCA
POLE
PAIR
PHASE
PB
P
PM
PT
PR
PH
PE
OSC
PNL
OOR
OPEN-STOP-CLOSE
PHASE MONITOR
POTENTIAL TRANSFORMER
PANELBOARD
PULL BOX
PHOTOCELL
OVERLOAD RELAY
NORMALLY OPEN
NOT TO SCALE
OPEN-CLOSE-AUTO
OPEN-CLOSE-REMOTE
OPEN-CLOSE (D)
ON-OFF-REMOTE
ON-OFF-AUTO
NAMEPLATE
MANUFACTURERS ASSOCIATION
SWITCH
ALUMINUM
AUTOMATIC TRANSFER
ALTERNATING CURRENT
AMMETER SWITCH,
AUTO-MANUAL
ALTERNATE
AL
AC
AFF
A
AM
ATS
AS
ALT
ABBV.
CIRCUIT
BREAKER
TRANSFORMER
CONDUIT, CONTACTOR
CIRCUIT BREAKER
CONTROL POWER
CONTROL RELAY
EXHAUST FAN
ELAPSED TIME METER
FULLY CLOSED
DISCONNECT
EQUIPMENT GROUND
C
CB
CT
CR
EF
EG
FC
DODE
DOE
DISC
ETM
EMH
CPT
EHD
CKT
BRKR
DELAY UPON DE-ENERGIZATION
ELECTRICAL MAHHOLE
DELAY UPON ENERGIZATION
ELECTRIC HAND DRYER
ABOVE FINISHED FLOOR
CMP
CURRENT TRANSFORMER
AMMETER, AMPERE, AMBER
DESCRIPTION
REDR
RMC
QNTY
R/I
RMS
RPC
RCPT
PVC
SWITCH
SWITCH
SF
SS
SC
S
SYM
SSRV
RTU
VOLTAGE STARTER
SOLID STATE REDUCED
STAINLESS STEEL, SELECTOR
SYMMETRICAL
SUPPLY FAN
ROOT MEAN SQUARE
POLYVINYL CHLORIDE CONDUIT
RESISTANCE TO CURRENT
REMOTE POWER CENTER
SURGE CAPACITOR
REMOTE TELEMETRY UNIT
RIGID METAL CONDUIT
QUANTITY
CONVERTER
RECEPTACLE
TO
TR
TDR
TJB
TDAD
TDAE
TYPICAL
V
VFI
WP
TSP
VFD
TYP
UVR
TS
TWISTED SHIELDED PAIR
WEATHERPROOF
VACUUM FAULT INTERRUPTER
VOLTMETER, VOLT
UNDER VOLTAGE RELAY
VARIABLE FREQUENCY DRIVE
TIME DELAY AFTER
DE-ENERGIZATION
TIME DELAY RELAY
TERMINAL JUNCTION BOX
TIME DELAY AFTER
THERMAL SWITCH
TRIPLE, TIMING RELAY
TIMED OPEN
ENERGIZATION
TC TIMED CLOSE
XFMR TRANSFORMER
FUTURE
GALVANIZED
FLOW METER
FLOW TRANSMITTER
FLOAT SWITCH
GREEN, GROUND
FULL VOLTAGE
GROUND
GROUND FAULT RELAY
HAND-OFF-REMOTE
HANDHOLE
HAND-0FF-AUTO
GENERATOR
FM
FS
FT
G
HF
HH
GFI
HOR
HOA
GRS
GFR
GND
GALV
GEN
FVNR
FUT
CONTROL
KILOWATT
LOAD BREAK SWITCH
LIGHTNING ARRESTER
INSTRUMENTATION AND
JUNCTION BOX
KEY INTERLOCK
LIMIT SWITCH
LIGHTING
MANUFACTURER
MANUAL-AUTO
LIGHTING PANEL
LIGHTING CONTACTOR
IC
JB
LBS
KW
LA
K
LS
LTG
LP
LR
MA
M
LC
MANUF
LT FLEX
I & C
MCP
MCC
GROUND FAULT INTERRUPTER
LOCAL-REMOTE, LATCHING RELAY
MOTOR CONTROL CENTER
MOTOR CIRCUIT PROTECTOR
MAGNETIC CONTACTOR COIL
LIQUID TIGHT FLEX CONDUIT
GALVANIZED RIGID STEEL
INSTANTANEOUS CLOSE
HARMONIC FILTER
NON-REVERSING STARTER
FEEDERFDR
DESCRIPTIONSYMBOL
SYMBOL
2#12, 1#12G, 1'C a or a 17
DESCRIPTION
F60/40
100/M
225400 aOS
HID HIGH INTENSITY DISCHARGE
NONFUSED DISCONNECT SWITCH, SIZE INDICATED, 3 POLE UNLESS INDICATED
OTHERWISE, NEMA 1 ENCLOSURE, WP = WEATHERPROOF (NEMA 4X)
FUSED DISCONNECT SWITCH, SIZE INDICATED (60/40, 60 = SWITCH RATING:40 =
FUSE RATING) 3 POLE UNLESS INDICATED OTHERWISE, NEMA 1 ENCLOSURE, WP
= WEATHERPROOF (NEMA 4X)
STARTER MAGNETIC NEMA SIZE INDICATED, NEMA 1 ENCLOSURE, UNLESS
INDICATED OTHERWISE. SEE CONTROL DIAGRAM
COMBINATION (FUSE OR CIRCUIT BREAKER AS INDICATED). MAGNETIC STARTER,
NEMA SIZE INDICATED, NEMA 1 ENCLOSURE UNLESS INDICATED OTHERWISE. SEE
CONTROL SCHEMATIC DIAGRAM
CONTACT - NORMALLY OPEN WITH NEMA SIZE INDICATED OR COIL
IDENTIFICATION AS APPLICABLE
CONTACT - NORMALLY CLOSED WITH NEMA SIZE INDICATED OR COIL
IDENTIFICATION AS APPLICABLE
CIRCUIT BREAKER, MAGNETIC, TRIP SHOWN, 3 POLE UNLESS INDICATED
OTHERWISE
CIRCUIT BREAKER, THERMAL MAGNETIC TRIP SHOWN, 3 POLE UNLESS INDICATED
OTHERWISE
CIRCUIT BREAKER WITH CURRENT LIMITING FUSES, TRIP AND FUSE RATING
INDICATED, 3 POLE UNLESS INDICATED OTHERWISE
V
SW
or
120V
0-600V
GFR
O AH
1 XOO
X O
AUTO
O O
OFF
O X
HAND
G - GREEN
50 INSTANTANEOUS
TIME OVERCURRENT
W - WHITE
R - RED
CKT.2
A
(3)
200/5
OOX
XX
LETTER INDICATES COLOR
PROTECTIVE RELAY
XX = 47
C - CLEAR
A - AMBER
B - BLUE
POSITION
PHASE FAILURE/PHASE REVERSE
PUSH-TO-TEST AND CONNECT, INDICATING LIGHT
O - OPEN CONTACT
X - CLOSED CONTACT
CURRENT TRANSFORMER, NUMBER AND RATIO INDICATED
L
LR
U
DCR
SOL
CR
GROUND FAULT/GROUND SENSOR51GS
XXX
YYY
DESCRIPTIONSYMBOL
KK
LIMIT SWITCH
TEMPERATURE
CLOSES ON RISING TEMPERATURE,
OPENS ON FALLING TEMPERATURE
OPENS ON RISING TEMPERATURE,
CLOSES ON FALLING TEMPERATURE
OPENS ON RISING PRESSURE, CLOSES ON FALLING
PRESSURE
CLOSES ON RISING PRESSURE, OPENS ON FALLING
PRESSURE
OPENS ON RISING FLOW, CLOSES ON FALLING FLOW
CLOSES ON RISING FLOW, OPENS ON FALLING FLOW
HELD OPEN, NORMALLY CLOSED
NORMALLY CLOSED
NORMALLY OPEN
HELD CLOSED, NORMALLY OPEN
FLOW
PRESSURE
LIQUID LEVEL
OPENS ON RISING LEVEL, CLOSES ON FALLING LEVEL
CLOSES ON RISING LEVEL, OPENS ON FALLING LEVEL
NORMALLY CLOSED, TIMED CLOSED
NORMALLY CLOSED, TIMED OPEN
NORMALLY OPEN, TIMED CLOSED
NORMALLY OPEN, TIMED OPEN
TIME DELAY CONTACTS
LATCHING RELAY
ELECTRIC RESISTANCE HEATERSOLENOID
CONTROL RELAY, 24V DC COIL
120V CONTROL RELAY
KIRK KEY INTERLOCK
FUSE
CAPACITOR OR SURGE CAPACITOR
METER WITH SWITCH - SCALE RANGE SHOWN
GROUND
TRANSFORMER, VOLTAGES, PHASE AND
RATING INDICATED AS APPLICABLE
120/240V
15 KVA
1 PH
GROUND FAULT RELAY WITH C.T.
PUSH-BUTTON SWITCH, MOMENTARY CONTACT, NORMALLY OPEN
PUSH-BUTTON SWITCH, MOMENTARY CONTACT, NORMALLY CLOSED
PUSH BUTTON SWITCH, MAINTAINED CONTACTS WITH MECHANICAL
INTERLOCK
REMOTE DEVICE
SELECTOR SWITCH: MAINTAINED CONTACT WITH CONTACT POSITION
INDICATED, CHART IDENTIFIES OPERATION
CENTRAL MONITORING PNL
LIGHTNING ARRESTER
DRAWOUT FUSED SWITCH, MEDIUM VOLTAGE
DRAWOUT CIRCUIT BREAKER, MEDIUM VOLTAGE
DRAWOUT CIRCUIT BREAKER, LOW VOLTAGE,
XXX = TRIP RATING RATING, YYY = FRAME
SWITCH - CURRENT RATING INDICATED, 3 POLE UNLESS INDICATED
OTHERWISE
FUSED SWITCH, SWITCH AND FUSE CURRENT RATING INDICATED, 3 POLE UNLESS
INDICATED OTHERWISE
MAGNETIC STARTER WITH NEMA SIZE INDICATED
OVERLOAD RELAY HEATER
INDICATES RACEWAY AND CIRCUIT CONDUCTORS. FIRST
NUMBER IS RACEWAY SIZE. THE FOLLOWING NUMBERS ARE
THE CONDUCTOR QUANTITIES, SIZES, AND TYPES
MAJOR ELECTRICAL COMPONENT OR DEVICE - NAME OR
IDENTIFYING SYMBOL AS SHOWN
PANELBOARD
TERMINAL JUNCTION BOX
WOUND-ROTOR MOTOR, HORSEPOWER INDICATED
MOTOR, SQUIRREL CAGE INDUCTION - HORSEPOWER
INDICATED
LUMINAIRE - SEE SCHEDULE # =
SEE FIXTURE SCHEDULE
LUMINAIRE - SEE SCHEDULE # =
SEE FIXTURE SCHEDULE
WALL MOUNTED LUMINAIRE - SEE SCHEDULE # =
SEE FIXTURE SCHEDULE
EXIT LIGHTS - SEE SCHEDULE # =
SEE FIXTURE SCHEDULE
EMERGENCY LIGHTING FIXTURE
# = SEE FIXTURE SCHEDULE
SMALL LETTER SUBSCRIPT AT SWITCH AND LUMINAIRE
INDICATES SWITCHING. SUBSCRIPT NUMBER AT LUMINAIRE
INDICATES CIRCUIT IN PANELBOARD
EXPOSED CONDUIT
CONDUIT DOWN, X IS CONDUIT NO.
CONDUIT UP
CONDUIT, STUBBED AND CAPPED AS SHOWN
ONE LINE DIAGRAMS, RISER DIAGRAMS AND SCHEMATICS
DESCRIPTIONSYMBOL
MEDIUM VOLTAGEMV
VD VOLTAGE DROP
WEATHERPROOF
FOUR WAY
RECESSED TV BOX
GROUND FAULT INTERRUPTER
4-
2-
3- THREE WAY
FOUR WAY
DOUBLE POLE
WP-
TL- TWIST LOCK
WEATHERPROOF TV-
GFI-
4-
WP-
CONVENIENCE RECEPTACLE - DUPLEX UNLESS SPECIFIED
OTHERWISE
WALL SWITCH:
RECESSED TV BOXWP-
TL- TWIST LOCK
WEATHERPROOF TV-
CONVENIENCE RECEPTACLE - QUADRUPLEX UNLESS SPECIFIED
OTHERWISE
CONVENIENCE RECEPTACLE, PEDESTAL OR ABOVE
COUNTER DUPLEX, UNLESS INDICATED OTHERWISE.
FLOOR BOX - ONE 20A DUPLEX RECEPTACLE AND TWO
DATA JACKS UNLESS SPECIFIED OTHERWISE MOUNTED
FLUSH IN FLOOR
a-LOWERCASE LETTER DESIGNATES SWITCH ID
OS OCCUPANCY CEILING OR WALL SENSOR, SEE LIGHTING CONTROL AND SENSOR
SCHEDULE FOR TYPE
OCCUPANCY SENSOR WALL SWITCH, SEE LIGHTING CONTROL AND SENSOR
SCHEDULE FOR TYPE:
a-LOWERCASE LETTER DESIGNATES SWITCH ID a a
LR OCCUPANCY LIGHTING RELAY, SEE LIGHTING CONTROL AND SENSOR SCHEDULE
FOR TYPE
a-LOWERCASE LETTER DESIGNATES SWITCH ID
O$ a
GROUND FAULT INTERRUPTERGFI-
GROUND FAULT INTERRUPTERGFI-
ENERGY REDUCING MAINTENANCE
SWITCH
W - WALL MOUNTED, 54" AFF
J JUNCTION BOX NEMA 12 ENCLOSURE UNLESS INDICATED
OTHERWISE. 4X = NEMA 4X SS
W = WALL MOUNTED, F = FLOOR MOUNTED,
C = CEILING MOUNTED
DUAL TELEPHONE/DATA RECEPTACLE, 1 VOICE AND 1 DATA
(OUTLET BOX, 18" AFF)
S SECURITY/BURGLAR 4"X4" JUNCTION BOX NEMA 12
ENCLOSURE UNLESS INDICATED OTHERWISE. 4X = NEMA 4X
SS
W = WALL MOUNTED, F = FLOOR MOUNTED,
C = CEILING MOUNTED
[B2]
LP-#
CONDUIT/CONDUCTOR - REFER TO CIRCUIT LEGEND
HOME RUN - PANEL AND CIRCUIT NUMBER SHOWN
CR
CCTV
CARD ACCESS CONTROL 2"X4" WALL MOUNTED JUNCTION
BOX NEMA 12 ENCLOSURE UNLESS INDICATED OTHERWISE.
4X = NEMA 4X SS
CCTV 4"X4" JUNCTION BOX NEMA 12 ENCLOSURE UNLESS
INDICATED OTHERWISE. 4X = NEMA 4X SS
W = WALL MOUNTED, F = FLOOR MOUNTED,
C = CEILING MOUNTED
DC CARD ACCESS CONTROL 6"X6" JUNCTION BOX NEMA 12
ENCLOSURE UNLESS INDICATED OTHERWISE. 4X = NEMA 4X
SS
W = WALL MOUNTED, F = FLOOR MOUNTED,
C = CEILING MOUNTED
SOOW EQUIPMENT CORD WITH RECEPTACLE
G
GROUND ROD
GROUND WIRE, 4/0 UNLESS OTHERWISE NOTED
EL
EC
TR
IC
AL
L
EG
EN
D
E-2
PROJ
DATE
D
RR
EV
IS
IO
N
C H
K
BY
AP
VD
SHEET
DWG
1 2 3 4 5 6
A
B
C
D
EN
G
R
SE
AL
C O
M M
U N
IT
Y
PL
AN
N
IN
G
D
EV
EL
O
PM
EN
T
SE
M
IN
O
LE
T R
IB
E
O F
FL
O
R
ID
A
G
R
IF
FI
N
R D
D
AV
IE
, F L
PH
(9
) 9
-6
D
AT
E N
O
Know what's
R
Call before you dig.
below.
N/A
SEMINOLE TRIBE OF FLORIDA
PUBLIC WORKS DEPARTMENT
CONTACT TWO (2) BUSINESS DAYS BEFORE DIGGING
HTTP://TED.SEMTRIBE.COM/FORMS-LIBRARY
DIGPUBLICWORKS@SEMTRIBE.COM
(954) 894-1060 - EXT. 10910
07/25
B
IG
C Y
P R
E S
S R
E -P
U M
P S
T A
T
IO
N
JW
K
JW
K
AL
C
JW
K
2403-31
JAMES W. KAPPES
FL P.E. NO. 71499
HSQ GROUP, LLC.Engineers · Planners · Surveyors4577 N Nob Hill Road, Suite 210Sunrise, Florida 33351 · 954.440.6990
C26258 · LB7924
H S
Q G
R O
U P
, I N
C
En gi ne er s
· P la nn er s
· S ur ve yo rs
N ob H ill R oa d, S ui te
Su nr is e, F lo rid a
· 9
.4
.6
C
· L
B7
C
E
EXISTING
PANEL A
EXIST. REPUMP
STATION
[A]
NEW CANOPY
NEW CANOPY
EXISTING
VALVE
PIT
EXISTING
VALVE PIT
EXISTING
METER
EXISTING
ELECTRICAL ROOM
E
E
[B]
[B]
O H
E O
H E
O H
E O
H E
O H
E
EXISTING GLADES
ELECTRIC POWER POLE
WITH POLE MOUNTED
TRANSFORMERS
EXISTING CT JUNCTION BOX,
CT METER AND MAIN DISC.
ELECTRICAL CANOPY PLAN.
REFER TO SHEET E-4 FOR
ENLARGED VIEWEXISTING LIGHT POLE
TO BE REMOVED
EXISTING LIGHT CONDUIT
AND CONDUCTOR SYSTEM
TO BE REMOVED
EXISTING LIGHT POLE
TO REMAIN
EXISTING LIGHT POLE
TO REMAIN
EXISTING LIGHT POLE
TO BE REMOVED
EXISTING LIGHT CONDUIT
SYSTEM TO REMAIN
EXISTING
PANEL PDP
ELECTRICAL CANOPY PLAN.
REFER TO SHEET E-4 FOR
ENLARGED VIEW
EXISTING CANOPY
TO BE REMOVED
EXISTING CANOPY
TO BE REMOVED
EXISTING LIGHT CONDUIT
SYSTEM TO REMAIN
E
[E]
[E]
NOTES:
LEGEND
DESCRIPTIONSYMBOL
CONTRACTOR SHALL FURNISH AND
INSTALL NEW EMT CONDUIT MOUNTED
IN ELECTRICAL ROOM. SEE RISERS
FOR SIZE AND QUANTITY OF CONDUIT
AND CONDUCTORS.
CONTRACTOR SHALL FURNISH AND
INSTALL NEW SCHEDULE 40 PVC
UNDER EXISTING PAVEMENT AND IN
DIRT. CONTRACTOR SHALL SAW CUT
EXISTING PAVEMENT. SEE RISERS
FOR SIZE AND QUANTITY OF CONDUIT
AND CONDUCTORS.
KEY NOTES:
EL
EC
TR
IC
AL
S
IT
E
PL
AN
E-3
NORTH
ELECTRICAL SITE PLAN
SCALE: 1' = 10'
E NEW ELECTRICAL PULL BOX. REFER
TO DETAILS FOR ADDITIONAL
INFORMATION.
CONDUIT AND CIRCUIT SCHEDULE
[A] = 2#10, 1#10G, 1"C (NORTH CANOPY LIGHTING)
2#10, 1#10G, 1"C (NORTH CANOPY RECEPTACLES)
2#10, 1#10G, 1"C (SOUTH CANOPY LIGHTING)
2#10, 1#10G, 1"C (SOUTH CANOPY LIGHTING)
[B] = 2#10, 1#10G, 1"C (CANOPY LIGHTING);
2#10, 1#10G, 1"C (CANOPY RECEPTACLES)
[C] = 2#10, 1#10G, 1"C (CANOPY RECEPTACLES)
[D] = 2#10, 1#10G, 1"C (CANOPY LIGHTING)
[E] = 2#12, 1#12G, 1/2"C (SITE LIGHTING)
PROJ
DATE
D
RR
EV
IS
IO
N
C H
K
BY
AP
VD
SHEET
DWG
1 2 3 4 5 6
A
B
C
D
EN
G
R
SE
AL
C O
M M
U N
IT
Y
PL
AN
N
IN
G
D
EV
EL
O
PM
EN
T
SE
M
IN
O
LE
T R
IB
E
O F
FL
O
R
ID
A
G
R
IF
FI
N
R D
D
AV
IE
, F L
PH
(9
) 9
-6
D
AT
E N
O
Know what's
R
Call before you dig.
below.
N/A
SEMINOLE TRIBE OF FLORIDA
PUBLIC WORKS DEPARTMENT
CONTACT TWO (2) BUSINESS DAYS BEFORE DIGGING
HTTP://TED.SEMTRIBE.COM/FORMS-LIBRARY
DIGPUBLICWORKS@SEMTRIBE.COM
(954) 894-1060 - EXT. 10910
07/25
B
IG
C Y
P R
E S
S R
E -P
U M
P S
T A
T
IO
N
JW
K
JW
K
AL
C
JW
K
2403-31
JAMES W. KAPPES
FL P.E. NO. 71499
HSQ GROUP, LLC.Engineers · Planners · Surveyors4577 N Nob Hill Road, Suite 210Sunrise, Florida 33351 · 954.440.6990
C26258 · LB7924
H S
Q G
R O
U P
, I N
C
En gi ne er s
· P la nn er s
· S ur ve yo rs
N ob H ill R oa d, S ui te
Su nr is e, F lo rid a
· 9
.4
.6
C
· L
B7
1. THE CONDUIT ROUTING SHOWN PROVIDES ONE SUGGESTED METHOD FOR ROUTING OF CONDUIT AND FOR PERFORMING THE WORK. THE SUGGESTED ROUTING SHALL BE USED FOR BIDDING PURPOSES ONLY.
THE CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDUIT ROUTING AND COORDINATE EXACT ROUTING
WITH OWNER AND ENGINEER PRIOR TO INSTALLATION.
2. CONTRACTOR SHALL VERIFY SIZE AND QUANTITY OF CONDUITS TO BE INSTALLED WITH THE RISER/ONE
LINE DIAGRAM.
3. CONTRACTOR SHALL FURNISH AND INSTALL RMC CONDUIT ON EXTERIOR OF THE BUILDING.
4. CONTRACTOR SHALL CORE DRILL ALL EXISTING WALLS TO INSTALL NEW CONDUITS AND REPAIR TO
MATCH EXISTING WALL RATING.
5. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUITS A MINIMUM OF 24" BELOW GRADE.
6. ALL CONDUITS UNDER ROADWAYS SHALL BE CONCRETE ENCASED. ENCASEMENT SHALL EXTEND 3FT
BEYOND EDGE OF PAVEMENT.
7. CONTRACTOR SHALL TRANSITION FROM UNDERGROUND PVC CONDUIT TO RMC CONDUIT BELOW GRADE
BEGINNING WITH A RMC 90 DEGREE ELBOW. COAT ALL UNDERGROUND RMC WITH TWO COATS OF
BITUMASTIC TO 6" ABOVE GRADE.
CONTRACTOR SHALL PROVIDE AND INSTALL EXPOSED RMC CONDUIT ON EXTERIOR OF BUILDING AND TRANSITION TO EMT ON THE INSIDE OF THE BUILDING. CONTRACTOR SHALL CORE DRILL WALL FOR ALL
CONDUIT PENETRATIONS. CONTRACTOR SHALL PAINT CONDUIT TO MATCH BUILDING EXTERIOR.
CONTRACTOR SHALL DISCONNECT, REMOVE AND DISPOSE OF THE EXISTING LIGHT POLE, COMPLETE.
REMOVE CONDUCTORS BACK TO ADJACENT LIGHT POLES. PROVIDE AND INSTALL NEW PULL BOX AND INTERCEPT EXISTING CONDUIT SYSTEM. PROVIDE AND INSTALL NEW CONDUCTORS VIA EXISTING
CONDUIT AND NEW PULL BOX AS SHOWN TO MAINTAIN LIGHTING CIRCUIT.
CONTRACTOR SHALL DISCONNECT, REMOVE AND DISPOSE OF THE EXISTING LIGHT POLE, COMPLETE.
REMOVE CONDUIT AND CONDUCTORS BACK TO ADJACENT LIGHT POLE.
E
Sa A-39 a
GFI
GFI
a a a
LIGHTNING PROTECTION
DOWN CONDUCTOR,
TYPICAL
4/0 BARE TINNED
COPPER TYP.
A-39
A-37 [D]
[C]
[B]
A-37 A-37
A-37 A-37
E b b bb
LIGHTNING PROTECTION
DOWN CONDUCTOR,
TYPICAL
A-8 S b
GFIGFI
A-8
A-6
4/0 BARE TINNED
COPPER TYP.
[D]
[C]
[B]
E
A-6A-6
A-6 A-6
NOTES:
KEY NOTES:
CONTRACTOR SHALL PROVIDE AND INSTALL A 4/0 BARE COPPER
GROUND WIRE FROM CANOPY FRAME TO NEW GROUND RING.
CONTRACTOR SHALL BOLT THROUGH CANOPY FRAME FOR
GROUND CONNECTION.
CONTRACTOR SHALL MOUNT RECEPTACLE AND LIGHT SWITCH
ON CANOPY FRAME 48" ABOVE FINISHED GRADE.
EL
EC
TR
IC
AL
C
AN
O
PY
P
LA
N
E-4
NORTH
NORTH CANOPY ELECTRICAL PLAN
SCALE: 1/4" = 1'
CONDUIT AND CIRCUIT SCHEDULE
[A] = 2#10, 1#10G, 1"C (NORTH CANOPY LIGHTING)
2#10, 1#10G, 1"C (NORTH CANOPY RECEPTACLES)
2#10, 1#10G, 1"C (SOUTH CANOPY LIGHTING)
2#10, 1#10G, 1"C (SOUTH CANOPY LIGHTING)
[B] = 2#10, 1#10G, 1"C (CANOPY LIGHTING);
2#10, 1#10G, 1"C (CANOPY RECEPTACLES)
[C] = 2#10, 1#10G, 1"C (CANOPY RECEPTACLES)
[D] = 2#10, 1#10G, 1"C (CANOPY LIGHTING)
[E] = 2#12, 1#12G, 1/2"C (SITE LIGHTING)
PROJ
DATE
D
RR
EV
IS
IO
N
C H
K
BY
AP
VD
SHEET
DWG
1 2 3 4 5 6
A
B
C
D
EN
G
R
SE
AL
C O
M M
U N
IT
Y
PL
AN
N
IN
G
D
EV
EL
O
PM
EN
T
SE
M
IN
O
LE
T R
IB
E
O F
FL
O
R
ID
A
G
R
IF
FI
N
R D
D
AV
IE
, F L
PH
(9
) 9
-6
D
AT
E N
O
Know what's
R
Call before you dig.
below.
N/A
SEMINOLE TRIBE OF FLORIDA
PUBLIC WORKS DEPARTMENT
CONTACT TWO (2) BUSINESS DAYS BEFORE DIGGING
HTTP://TED.SEMTRIBE.COM/FORMS-LIBRARY
DIGPUBLICWORKS@SEMTRIBE.COM
(954) 894-1060 - EXT. 10910
07/25
B
IG
C Y
P R
E S
S R
E -P
U M
P S
T A
T
IO
N
JW
K
JW
K
AL
C
JW
K
2403-31
JAMES W. KAPPES
FL P.E. NO. 71499
HSQ GROUP, LLC.Engineers · Planners · Surveyors4577 N Nob Hill Road, Suite 210Sunrise, Florida 33351 · 954.440.6990
C26258 · LB7924
H S
Q G
R O
U P
, I N
C
En gi ne er s
· P la nn er s
· S ur ve yo rs
N ob H ill R oa d, S ui te
Su nr is e, F lo rid a
· 9
.4
.6
C
· L
B7
SOUTH CANOPY ELECTRICAL PLAN
SCALE: 1/4" = 1'
1. GROUNDS SHALL NOT BE DAISY CHAINED.
2. BELOW GRADE GROUND CONNECTIONS SHALL BE EXOTHERMIC WELDS OR
MECHANICAL COMPRESSION TYPES PER SPECIFICATION 260526. ALL BELOW GRADE
CONNECTIONS SHALL BE COATED WITH COAL TAR.
3. ABOVE GRADE GROUND CONNECTIONS SHALL BE CRIMPED LUG AND A STAINLESS
STEEL BOLTED CONNECTION.
4. CONTRACTOR SHALL FURNISH AND INSTALL LIGHTNING PROTECTION SYSTEM FOR
THE CANOPY AS PER SPECIFICATION SECTION 264100.
5. CONTRACTOR SHALL FURNISH AND INSTALL CONDUIT A MINIMUM OF 24" BELOW
GRADE.
6. CONTRACTOR SHALL TRANSITION FROM UNDERGROUND PVC CONDUIT TO RMC
CONDUIT BELOW GRADE BEGINNING WITH A RMC 90 DEGREE ELBOW. COAT ALL
UNDERGROUND RMC WITH TWO COATS OF BITUMASTIC TO 6" ABOVE GRADE.
F Ratings - 1 & 2 Hr (See Item 4)
L Rating At 400 F - 4 CFM/Sq Ft
1A2
1BSECTION A-A
A
A
L Rating At Ambient - Less Than 1 CFM/Sq Ft T Ratings - 0 and 2 Hr (see Item 4)
1. Floor or Wall Assembly: The fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features:
A. Studs: Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. on center. Steel studs to be min 2-1/2 in. wide and spaced max 24 in. on center.
B. Gypsum Board*: Nom 5/8 in. thick gypsum wallboard, as specified in the individual Wall and Partition Design. Max diameter of opening is 4 in.
2. Metallic Sleeve (Optional): Nom 4 in. diameter (or smaller) Schedule 40 (or thinner) steel pipe cast into wall assembly with joint compound and installed flush with wall surfaces.
3. Electrical Nonmetallic Tubing+: Nom 2 in. diameter (or smaller) corrugated wall electrical nonmetallic tubing (ENT) constructed of polyvinyl chloride (PVC). Tubing to be rigidly supported on both sides of wall assembly. A nom annular space of 3/4 in. is required within the fire stop system. (FKHU) category in the Electrical Construction Materials Directory for See Electrical Nonmetallic Tubing names of manufacturers.
4. Fill, Void or Cavity Material*: Sealant: Installed symmetrically on both sides of the wall.
The hourly F Rating of the fire stop system is equal to the hourly fire rating of the wall assembly in which it is installed. Fill material applied within the annulus, flush with each end of the steel sleeve at the thickness shown in the table below:
F Rating Hr T Rating Hr Fill Mtl Depth In.
1 0 5/8 2 2 1-1/4
NOT TO SCALE
1. Floor or Wall Assembly: Min 4-1/2 in. thick reinforced lightweight or normal weight (100-150 pcf) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 32 in.
2. Metallic Sleeve: (Optional) Nom 32 in. diam (or smaller) Schedule 40 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces.
3. Through-Penetrant One metallic pipe or conduit to be installed either concentrically or eccentrically within the firestop system. The annular space between pipe or conduit and periphery of opening shall be min 0 in. (point contact) to max 1-7/8 in. Pipe may be installed with continuous point contact. Pipe or conduit to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes or conduits may be used:
A. Steel Pipe Nom 30 in. diam (or smaller) Schedule 10 (or heavier) steel pipe.
B. Iron Pipe Nom 30 in. diam (or smaller) cast or ductile iron pipe.
C. Copper Pipe Nom 6 in. diam (or smaller) Regular (or heavier) copper pipe.
D. Copper Tubing Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing.
E. Conduit Nom 6 in. diam (or smaller) steel conduit. f F. Conduit Nom 4 in. diam (or smaller) steel electrical metallic tubing (EMT).
4. Firestop System The firestop system shall consist of the following:
A. Packing Material Min 4 in. thickness of min 4 pcf mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material.
B. Fill, Void or Cavity Material* -- Sealant Min 1/4 in. thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall. At the point or continuous contact locations between pipe and concrete, a min 1/4 in. diam bead of fill material shall be applied at the concrete/pipe interface on the top surface of floor and on both surfaces of wall.
A
SECTION A-A
L Rating At Ambient - Less than 1 CFM/Sq Ft L Rating At 400 F - 4 CFM/Sq Ft
4B
4A
A
4B
T RATING = 0-HR.
F RATING = 3-HR.
NOT TO SCALE
FIRE STOPPING SYSTEM N0. W-L-2075
FIRE STOPPING SYSTEM N0. C-AJ-1226
NOT TO SCALE
"PANEL A" PARTIAL RISER DIAGRAM
KEYED NOTES:
CONTRACTOR SHALL PROVIDE AND INSTALL A NEW BREAKER IN EXISTING
PANELBOARD. BREAKER SHALL MATCH EXISTING MANUFACTURE AND AIC RATING.
EXISTING PANEL A
RECEPTACLES
GFI
WP
20A
2#10, 1#10G, 3/4"C
LIGHTS
NORTH
CANOPY
2#10, 1#10G, 1"C
S
2#10, 1#10G, 1"C
RECEPTACLES
GFI
WP
20A
2#10, 1#10G, 3/4"C
LIGHTS
SOUTH
CANOPY
2#10, 1#10G, 1"C
S
2#10, 1#10G, 1"C
EL
EC
TR
IC
AL
D
ET
AI
LS
E-5
PROJ
DATE
D
RR
EV
IS
IO
N
C H
K
BY
AP
VD
SHEET
DWG
1 2 3 4 5 6
A
B
C
D
EN
G
R
SE
AL
C O
M M
U N
IT
Y
PL
AN
N
IN
G
D
EV
EL
O
PM
EN
T
SE
M
IN
O
LE
T R
IB
E
O F
FL
O
R
ID
A
G
R
IF
FI
N
R D
D
AV
IE
, F L
PH
(9
) 9
-6
D
AT
E N
O
Know what's
R
Call before you dig.
below.
N/A
SEMINOLE TRIBE OF FLORIDA
PUBLIC WORKS DEPARTMENT
CONTACT TWO (2) BUSINESS DAYS BEFORE DIGGING
HTTP://TED.SEMTRIBE.COM/FORMS-LIBRARY
DIGPUBLICWORKS@SEMTRIBE.COM
(954) 894-1060 - EXT. 10910
07/25
B
IG
C Y
P R
E S
S R
E -P
U M
P S
T A
T
IO
N
JW
K
JW
K
AL
C
JW
K
2403-31
JAMES W. KAPPES
FL P.E. NO. 71499
HSQ GROUP, LLC.Engineers · Planners · Surveyors4577 N Nob Hill Road, Suite 210Sunrise, Florida 33351 · 954.440.6990
C26258 · LB7924
H S
Q G
R O
U P
, I N
C
En gi ne er s
· P la nn er s
· S ur ve yo rs
N ob H ill R oa d, S ui te
Su nr is e, F lo rid a
· 9
.4
.6
C
· L
B7
NOT TO SCALE
316 STAINLESS STEEL STRAPS
AND HARDWARE
ANCHOR TO WALL WITH 3/8"
DIA. X 4" 316 STAINLESS STEEL
CONCRETE ANCHORS, WITH
SUPPORTS AT 5"-0" MAXIMUM.
316 STAINLESS STEEL
CHANNEL
1/2" 316 STAINLESS STEEL
THREADED ROD SUPPORT
FROM BUILDING STRUCTURE.
NOT TO SCALE
NOT TO SCALE
1 1/2" X 1 1/2" 316 STAINLESS
STEEL CHANNEL
1. THIS DETAIL TYPICAL FOR BOTH VERTICAL AND
HORIZONTAL MOUNTING.
2. CHANNEL AND ALL SUPPORT DEVICES TO BE 316
STAINLESS STEEL. FIELD COAT ALL CUTS, ETC. TO
MATCH.
3. CHANNELS TO BE SPACED 5' MAXIMUM.
U.L APPROVED FIRE RATED
JOINT FILLER
WALL OR SLAB
CAULK ENDS ALL AROUND
TYPICAL BOTH SIDES
CONDUIT
CORE DRILL OPENING
ALL CONDUIT SHALL BE
GROUNDED WITH
GROUNDING BUSHINGS
GROUND WIRE
(GROUND ONE
END OF CONDUIT
ONLY)
LOCK WASHER
EQUIPMENT
ENCLOSURE CONDUIT
NOT TO SCALE
NOT TO SCALE
CONDUIT PENETRATION AT
WALL OR SLAB
CONDUIT GROUNDING
CONDUIT SUPPORT
CONDUIT SUPPORTING AND MOUNTING NOTES:
TRAPEZE ASSEMBLY
CONDUIT PIPE STRAP
MOUNTING DETAILS
316 STAINLESS STEEL
CONDUIT CLAMP
NOTE:
MOUNTED DEVICE
WALL OR COLUMN
NOT TO SCALE
ALL MOUNTING HARDWARE SHALL BE STAINLESS STEEL.
FLOOR OR PLATFORM
WIRING DEVICE OR
ELECTRICAL EQUIPMENT
SIZE AS REQD
WALL OR COLUMN
PIPE STRAP
CONDUIT
NOT TO SCALE
3"
" M
IN
FINISH
GRADE
SCH 40 PVC
CONDUIT
TYPICAL PAVEMENT REPAIR OVER
SINGLE CONDUIT CONCRETE ENCASED
3"
3"
CONCRETE ENCASEMENT,
MINIMUM 3000 PSI. WITH 3"
MINIMUM COVER ALL AROUND
ASPHALT REPAIR SEE
CIVIL DETAILS
6"
3/4 " DIA X 20'-0"
COPPER CLAD
GROUND ROD
4/0 AWG BARE
TINNED COPPER
TYPE "TA" CADWELD
CONNECTION
30"
NOT TO SCALE
BURIAL DEPTH
MINIMUM
NOT TO SCALE
GROUND CABLE CONNECTION
BARE
TINNED
COPPER
GROUND
CABLE
TYPE "TA" EXOTHERMIC
CONNECTION
GROUND ROD/GROUND RING DETAIL
PLASTIC 6" WIDE LOCATABLE
TAPE MARKED "ELECTRICAL",
TYPICAL OVER ALL CONDUITS.
3"
" M
IN
FINISH
GRADE
SCH 40 PVC CONDUIT
PLASTIC 6" WIDE
LOCATABLE TAPE MARKED
"ELECTRICAL" , TYPICAL
OVER ALL CONDUITS.
8"
COMPACTED EARTH,
MIN. 98% DENSITY
3"
3"
EARTH
CLEAN AND BACKFILL
WITH EARTH
NOT TO SCALE
TYPICAL CONDUIT IN EARTH
MINIMUM
24"
8"
FINISHED GRADE
ALL UNDERGROUND WATERPROOF SPLICES SHALL
BE MADE WITH PROVIDE ESSLK-2/0 SPLICES FOR
LIGHTING CIRCUITS ONLY.
POLYMER TIER 15 HEAVY DUTY, SKID
RESISTANT & TRAFFIC RATED COVER,
BOLTED DOWN WITH STAINLESS STEEL
HARDWARE, MARKED "ELECTRICAL
POLYMER PULL BOX W/BASE,
13"Wx24"Lx12"D I.D. MINIMUM SIZE, ENLARGE SIZE TO MEET NEC AND
INSTALL PER MANUFACTURER'S
RECOMMENDATIONS.
8" DEPTH OF
CRUSHED
STONE OR
GRAVEL FOR
DRAINAGE
SEE PLAN FOR CONDUIT
AND WIRE
REQUIREMENTS
DIRECT BURIED 8"
IDENTIFICATION TAPE
GROUND ROD
3/4" DIA X 20'-0" (TYPICAL
OF LIGHTING PULL BOX
ONLY)
PROVIDE
DUCTSEAL IN
CONDUITS TYP.
NOT TO SCALE
PULL BOX DETAIL
PAVEMENT, COMPACTED
EARTH, MIN. 98%
DENSITY
EL
EC
TR
IC
AL
D
ET
AI
LS
E-6
PROJ
DATE
D
RR
EV
IS
IO
N
C H
K
BY
AP
VD
SHEET
DWG
1 2 3 4 5 6
A
B
C
D
EN
G
R
SE
AL
C O
M M
U N
IT
Y
PL
AN
N
IN
G
D
EV
EL
O
PM
EN
T
SE
M
IN
O
LE
T R
IB
E
O F
FL
O
R
ID
A
G
R
IF
FI
N
R D
D
AV
IE
, F L
PH
(9
) 9
-6
D
AT
E N
O
Know what's
R
Call before you dig.
below.
N/A
SEMINOLE TRIBE OF FLORIDA
PUBLIC WORKS DEPARTMENT
CONTACT TWO (2) BUSINESS DAYS BEFORE DIGGING
HTTP://TED.SEMTRIBE.COM/FORMS-LIBRARY
DIGPUBLICWORKS@SEMTRIBE.COM
(954) 894-1060 - EXT. 10910
07/25
B
IG
C Y
P R
E S
S R
E -P
U M
P S
T A
T
IO
N
JW
K
JW
K
AL
C
JW
K
2403-31
JAMES W. KAPPES
FL P.E. NO. 71499
HSQ GROUP, LLC.Engineers · Planners · Surveyors4577 N Nob Hill Road, Suite 210Sunrise, Florida 33351 · 954.440.6990
C26258 · LB7924
H S
Q G
R O
U P
, I N
C
En gi ne er s
· P la nn er s
· S ur ve yo rs
N ob H ill R oa d, S ui te
Su nr is e, F lo rid a
· 9
.4
.6
C
· L
B7
12.0 16.6 18.7 19.1 17.3 12.5
17.3 24.6 27.4 27.6 25.1 17.7
19.5 27.9 31.0 30.8 27.7 19.4
17.5 25.1 27.6 27.3 24.5 17.4
12.4 17.1 19.0 18.7 16.7 12.1
12.1 16.8 19.0 19.1 17.3 12.7
17.1 24.6 27.4 27.7 25.2 17.9
18.9 27.4 30.7 30.9 28.0 19.8
17.1 24.4 27.3 27.4 24.8 17.7
12.1 16.8 18.8 18.8 16.9 12.4
PH
O
TO
M
ET
R
IC
C
AN
O
PY
P
LA
N
E-7
N O
R
TH
NORTH CANOPY PHOTOMETRIC PLAN
SCALE: 1/4" = 1'
PROJ
DATE
D
RR
EV
IS
IO
N
C H
K
BY
AP
VD
SHEET
DWG
1 2 3 4 5 6
A
B
C
D
EN
G
R
SE
AL
C O
M M
U N
IT
Y
PL
AN
N
IN
G
D
EV
EL
O
PM
EN
T
SE
M
IN
O
LE
T R
IB
E
O F
FL
O
R
ID
A
G
R
IF
FI
N
R D
D
AV
IE
, F L
PH
(9
) 9
-6
D
AT
E N
O
Know what's
R
Call before you dig.
below.
N/A
SEMINOLE TRIBE OF FLORIDA
PUBLIC WORKS DEPARTMENT
CONTACT TWO (2) BUSINESS DAYS BEFORE DIGGING
HTTP://TED.SEMTRIBE.COM/FORMS-LIBRARY
DIGPUBLICWORKS@SEMTRIBE.COM
(954) 894-1060 - EXT. 10910
07/25
B
IG
C Y
P R
E S
S R
E -P
U M
P S
T A
T
IO
N
JW
K
JW
K
AL
C
JW
K
2403-31
JAMES W. KAPPES
FL P.E. NO. 71499
HSQ GROUP, LLC.Engineers · Planners · Surveyors4577 N Nob Hill Road, Suite 210Sunrise, Florida 33351 · 954.440.6990
C26258 · LB7924
H S
Q G
R O
U P
, I N
C
En gi ne er s
· P la nn er s
· S ur ve yo rs
N ob H ill R oa d, S ui te
Su nr is e, F lo rid a
· 9
.4
.6
C
· L
B7
SOUTH CANOPY PHOTOMETRIC PLAN
SCALE: 1/4" = 1'
GENERAL NOTES
1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, DETAILS, AND JOB SITE CONDITIONS PRIOR TO COMMENCING WORK AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES. ALL DIMENSIONS AND DRAWINGS SHOWN ON THESE PLANS ARE NOMINAL AND SHOW DESIGN INTENT ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE TO ADJUST ACTUAL CONSTRUCTION DIMENSIONS SLIGHTLY TO ALLOW FOR EXACT MATERIAL THICKNESS. ANY ITEM, MATERIAL, OR WORK NOT SHOWN ON THE DRAWINGS BUT MENTIONED IN THE SPECIFICATIONS, OR VICE VERSA, OR ANY INCIDENTAL ACCESSORIES NECESSARY TO MAKE THE WORK COMPLETE IN ALL RESPECTS AND READY FOR OPERATION SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR WITHOUT ADDITIONAL EXPENSE TO THE OWNER. ALL SYSTEMS AND THEIR ASSOCIATED INCIDENTAL ACCESSORIES MUST BE COMPLETELY INSTALLED, CONNECTED, AND OPERATING TO THE SATISFACTION OF THE ENGINEER PRIOR TO FINAL ACCEPTANCE BY THE
OWNER.
2. CONCRETE STRUCTURE MAY NOT SUPPORT THE DESIGN LIVE LOAD UNTIL CONCRETE HAS REACHEDTHE 28 DAYS.
3. THE CONTRACTOR IS FULLY RESPONSIBLE FOR THE SUPPORT OF TEMPORARY LOADS AND FORM WORK.
CONTRACTOR SHALL PROVIDE LATERAL SUPPORT FOR FALSE AND FORM WORK TO RESIST THE LATERAL MOVEMENT
DURING PLACEMENT OF CONCRETE.
4. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS AND LABOR NECESSARY TO CONSTRUCT THE ITEMS DEPICTED ON THESE PLANS. THE DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE AND, UNLESS
SPECIFICALLY NOTED OTHERWISE, DO NOT SHOW THE MEANS AND METHOD OF CONSTRUCTION.
5. THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHOD OF CONSTRUCTION, AND SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE PUBLIC, CONSTRUCTION WORKERS, AND THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE FORMING, SHORING, BRACING, SCAFFOLDING, ETC.
6. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL NECESSARY PERMITS, LICENSES, INSPECTIONS, AND ALL OTHER REQUIRED FEES. ALL WORK SHALL BE COMPLETED IN FULL COMPLIANCE WITH ALL CURRENT APPLICABLE CODES, ORDINANCES, AND GOVERNMENTAL REGULATIONS.
7. THE CONTRACTOR SHALL TURN OVER TO THE OWNER A CLEAN FACILITY WITH A CERTIFICATE OF OCCUPANCY, RECORD DOCUMENTS, INSPECTION CERTIFICATES, WARRANTIES AND BONDS, EVIDENCE OF PAYMENT, RELEASE OF
LIENS, AND ANY OPERATION AND MAINTENANCE MANUALS.
8. THE CONTRACTOR SHALL REVIEW THE COMPLETED WORK WITH THE ENGINEER AND/OR OWNER OR THEIR DESIGNATED REPRESENTATIVE AND DEMONSTRATE SATISFACTORY OPERATION OF EQUIPMENT AND/OR SATISFACTORY INSTALLATION OF STRUCTURAL SYSTEMS. ITEMS THAT THE ENGINEER, OWNER OR THEIR DESIGNATED REPRESENTATIVE DEEM UNSATISFACTORY AS IT RELATES TO THE SPECIFICATIONS WITHIN THESE PLANS SHALL BE
CORRECTED BY THE CONTRACTOR WITHOUT ADDITIONAL EXPENSE TO THE OWNER.
9. ALL WORK IS SUBJECT TO THE APPROVAL OF THE BUILDING OFFICIAL'S FIELD INSPECTOR.
10. DO NOT SCALE THESE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALES.
11. THE ENGINEER IS RESPONSIBLE FOR THE STRUCTURAL ITEMS IN THESE PLANS ONLY RELATED TO SLAB ON GRADE. IF ANY CHANGES ARE MADE FROM THE DESIGN AS SPECIFIED IN THESE DRAWINGS/CALCULATIONS WITHOUT APPROVAL FROM THE ENGINEER (I.E. ALTERATIONS TO THE STRUCTURAL SYSTEM OR ADDITION OF CONSTRUCTION MATERIALS/LOADS), THE ENGINEER WILL ASSUME NO RESPONSIBILITY FOR ANY ELEMENT OR SYSTEM OF THIS STRUCTURE PROVIDED BY THE MANUFACTURER'S ENGINEER. MANUFACTURER'S ENGINEER SHOULD PROVIDE SIGNED
AND SEALDED CANOPY FOUNDATION DRAWINGS.
12. THE CONTRACTOR OR OWNER SHALL SECURE ALL REQUIRED APPROVALS AND PERMITS FROM THE APPROPRIATE AGENCIES AS REQUIRED. IF THEY ELECT NOT TO OBTAIN A PERMIT, THESE PLANS SHALL BE CONSIDERED NULL AND
VOID.
13. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE, REMOVE AND RESET/RECONNECT ALL UTILITIES
AND MECHANICAL SYSTEMS AS NECESSARY.
14. IT IS THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL IMMEDIATELY INFORM THE ENGINEER OF ANY CONFLICTS OR DISCREPANCIES WITH THE WORK
PROPOSED IN THESE PLANS.
15. EXCEPT WHERE EXPLICITLY NOTED IN THESE DRAWINGS, MODIFICATION OF NEW/EXISTING STRUCTURAL MEMBERS (CUTTING, NOTCHING, BENDING, ETC.) IS NOT ALLOWED WITHOUT WRITTEN APPROVAL FROM THE ENGINEER.
16. ALL WORK SHALL BE WITHIN FLORIDA BUILDING CODE TOLERANCES FOR PLUMB, LEVEL, AND TRUE.
17. THE ENGINEER IS NOT RESPONSIBLE FOR THIS PLAN UNLESS ALL SHEETS ARE SEALED BY THE ENGINEER AND WET
SIGNED OVER THE SEAL WITH BLUE INK.
18. ANY REVISION, CORRECTION, OR OTHER NOTATION INDICATED ON THESE PLANS THAT ARE NOT COMPUTER- GENERATED (I.E. PENCIL, INK, MARKER, ETC.) ARE INVALID, HAVE NOT BEEN APPROVED BY THE ENGINEER AND SHALL NOT BE CONSIDERED A LEGITIMATE REVISION OR ADDENDUM TO THE PLAN. ANY REVISIONS OR ADDENDUMS TO THIS
PLAN WILL ONLY BE VALID IF ONE OF THE FOLLOWING METHODS ARE UTILIZED.
a. THE AFFECTED PORTIONS OF THE SET WILL BE ADDRESSED BY WAY OF A LETTER AND/OR DETAIL ON AN 8-1/2" X 11" (OR 11" X 17") ADDENDUM SHEET FROM THE ENGINEER AND WILL CONTAIN THE ENGINEER'S SEAL AND
WET SIGNATURE.
b. THE AFFECTED SHEET(S) WILL BE RE-ISSUED IN THEIR ENTIRETY AND WILL CONTAIN THE ENGINEER'S SEAL
AND WET SIGNATURE.
c. THE DRAWING SET WILL BE RE-ISSUED IN ITS ENTIRETY AND WILL CONTAIN THE ENGINEER'S SEAL AND WET
SIGNATURE.
19. FBC REFERS TO FLORIDA BUILDING CODE 8TH EDITION (2023).
20. FOR WINDOWS AND DOORS DIMENTIONS, LOCATIONS AND ELEVATIONS, REFER TO ARCHITECTURAL DRAWINGS AND
ALLIANCE ENGINEERING CANOPY DRAWINGS.
21. FOR CANOPY STRUCTURE, REFER TO ALLIANCE ENGINEERING CANOPY DRAWINGS.
CONCRETE
1. PROVIDE CONCRETE MIX WITH A f'c = 4,000 PSI MIN. COMPRESIVE STRENGTH AT 28 DAYS.
2. CONCRETE SHALL BE A MIX DESIGNED IN ACCORDANCE WITH A.C.I. 301 (LATEST EDITION) TO ACHIEVE A 28-DAY COMPRESSIVE STRENGTH AND A MAXIMUM WATER-CEMENT RATIO OF 0.40 AND A SLUMP OF 4"+ 1".
3. TRANSPORTATION, PLACING, AND CURING OF CONCRETE SHALL COMPLY WITH A.C.I. 318 BUILDING CODE (LATEST
EDITION).
4. ALL CONCRETE STRUCTURAL COMPONENTS SHALL HAVE CONCRETE STRENGTH TESTED IN ACCORDANCE WITH A.S.T.M. STANDARDS, FLORIDA BUILDING CODE 2023 AND ACI 318 (LATEST EDITION). TESTING LAB SHALL PROVIDE COPIES OF CONCRETE TESTS RESULTS TO ENGINEERS OFFICE FOR REVIEW. TAKE FOUR CONCRETE TEST CYLINDERS FOR EVERY 50 CU YARDS OR LESS OF EACH CLASS OF CONCRETE PLACED. TEST TO BE DONE AT THE CONCRETE AGE
OF: 7 DAYS, 14 DAYS AND 28 DAYS.
5. CONCRETE MIX DESIGN SHALL BE SUBMITTED TO ENGINEER'S OFFICE FOR REVIEW.
6. ALL REBAR COVER SHALL BE AS FOLLOWING SPECIFICATIONS (UNLESS OTHERWISE STATED ON PLANS):
A. PEDESTALS: GENERAL REBAR COVER TO BE 2" MINIMUM.
B. ISOLATED FOOTERS: ALL SIDES REBAR COVER TO BE 3" MINIMUM.
SAFETY OSHA AND LABOR LAWS
THE STRUCTURAL ENGINEER OF RECORD DOES NOT POSSES, NOR PRESUMES TO ANY KNOWLEDGE OR EXPERTISE IN MATTERS TO JOB SITE EMPLOYEE SAFETY, OSHA OR LABOR LAW REQUIREMENTS FOR A CONSTRUCTION PROJECT. SAFETY AND COMPLIANCE WITH OSHA AND LABOR LAWS ARE THE ABSOLUTE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THOSE CONSULTANTS HE HIRES TO ADDRESS THESE MATTERS. THE STRUCTURAL ENGINEER OF RECORD SPECIALIZES IN STRUCTURAL DESIGN ONLY, AND THE BOARD OF PROFESSIONAL REGULATION FORBIDS HIM FROM ASSUMING
RESPONSIBILITY OUTSIDE HIS AREA OF EXPERTISE.
APPLICABLE CODES:
ALTHOUGH THE ENGINEER OF RECORD HAS STRIVED TO MEET ALL APPLICABLE CODES AND LOCAL ORDINANCE REQUIREMENTS, THE CONTRACTOR IS STILL RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND ORDINANCES OF THE EVENT OF CONFLICT OR OVERSIGHT IN THE DRAWINGS, THE CONTRACTOR MUST IMMEDIATELY NOTIFY THE ARCHITECT OR ENGINEER OF ANY CONFLICT OR DISCREPANCY ENCOUNTERED SO THAT APPROPRIATE REMEDIES MAY BE
UNDERTAKEN.
THE FOLLOWING CODES WERE CONSIDERED IN THE DESIGN:
• FLORIDA BUILDING CODE 2023, 8TH EDITION
• ACI 318-19 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE
• ASCE 7-22 MINIMUM DESIGN LOAD MANUAL
DESIGN CRITERIA
THE STRUCTURAL COMPONENTS FOR THIS PROJECT HAVE BEEN DESIGNED IN COMPLIANCE WITH THE FLORIDA BUILDING
CODE (FBC) 2023.
THE FOLLOWING LOADS HAVE BEEN USED FOR FOUNDATION DESIGN:
PEDESTALS & FOOTINGS:
REFER TO CANOPY DRAWINGS & CALCULATIONS DOCUMENT BY ALLIANCE ENGINEERING, DATED APRIL 05, 2025.
WIND LOADS:
IN ACCORDANCE WITH ASCE 7-22 WITH 3-SECOND SUSTAINED WIND GUSTS.
WIND VELOCITY = 150 MPH
EXPOSURE = C
RISK CATEGORY = II
GCpi +/- = 0.00
OPEN BUILDING
NOTES:
• TORNADO VALUES ARE NOT APPLICABLE TO BUILDINGS OF RISK CATEGORY II AS PER SECTION 32.5 OF ASCE 7-22.
• FOR CANOPY LOADS, REFER TO STRUCTURAL CALCULATIONS DOCUMENT PREPARED BY ALLIANCE ENGINEERING
DATED APRIL 05, 2025.
REINFORCING STEEL
1. REINFORCING BARS CONFORMING TO A.S.T.M. A615 GRADE 60.
2. FABRICATION AND DETAILING ACCORDING TO A.C.I-315.
3. ALL ACCESSORIES SHALL HAVE UPTURNED LEGS, AND BE PLASTIC DIPPED AFTER FABRICATION; SHALL BE DEFORMED BARS, FREE FROM LOOSE RUST AND SCALE, AND CONFORMING TO A.S.T.M. A615 GRADE 60. ACCESSORIES FOR
REINFORCING SHALL BE INSTALLED IN ACCORDANCE WITH A.C.I. 315 CURRENT EDITION.
4. ALL PLACEMENT OF REINFORCING BARS SHALL BE IN ACCORDANCE WITH THE MANUAL OF STANDARD PRACTICE OF
THE CONCRETE REINFORCING STEEL INSTITUTE.
5. BAR DEVELOPMENT AND LAP SPLICE LENGTH CONTRACTOR MAY LAP SPLICE STEEL REINFORCING BARS AT
LOCATIONS OF HIS CHOOSING EXCEPT FOR THE FOLLOWING:
a. LONGITUDINAL CONCRETE SLAB TOP BARS SHALL BE SPLICED AT MID SPAN.
b. LONGITUDINAL CONCRETE SLAB BOTTOM BARS SHALL BE SPLICED AT SUPPORT(S).
ALL STEEL REINFORCING LAP SPLICES, UNLESS INDICATED OTHERWISE, SHALL SATISFY THE FOLLOWING:
ALL STEEL REINFORCING BAR DEVELOPMENT LENGTHS, UNLESS INDICATED. OTHERWISE, SHALL SATISFY THE FOLLOWING:
*TOP BAR IS DEFINED AS ANY HORIZONTAL BAR PLACED SUCH MORE THAN 12 INCHES OF CONCRETE IS PLACED BELOW THE BAR IN ANY SINGLE CONCRETE PLACEMENT. CONCRETE WALL HORIZONTAL STEEL
REINFORCING BARS ARE CONSIDERED TOP BARS.
SOIL STATEMENT
SOIL PREPARATION AND SUBGRADE COMPACTION SHALL BE PERFORMED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEER OF RECORD, PACIFICA. ALL SITE GRADING, FILL PLACEMENT AND SOIL IMPROVEMENTS SHALL CONFORM TO THE GEOTECHNICAL REPORT AND ANY SUBSEQUENT ADDENDA OR FIELD DIRECTIVES ISSUED BY PACIFICA.
THE GEOTECHNICAL REPORT PREPARED BY PACIFICA, DATED FEBRUARY 10, 2025, INDICATES THAT A DESIGN BEARING PRESSURE OF 2,500 PSF MAY BE UTILIZED FOR THE DESIGN OF SHALLOW BEARING ELEMENTS, PROVIDED THAT SOIL PREPARATION AND CONSTRUCTION ARE PERFORMED IN ACCORDANCE WITH THE REPORT RECOMMENDATIONS.
LAP SPLICE SCHEDULE
BAR SIZE #3 #4 #5 #6 #7 #8 #9 #10 #11
TOP BAR* 2'-2" 2'-10" 3'-6" 4'-3" 6'-0" 6'-9" 7'-8" 8'-6" 9'-4"
OTHER 1'-8" 2'-2" 2'-8" 3'-3" 4'-8" 5'-2" 5'-10" 6'-6" 7'-2"
DEVELOPMENT LENGTH SCHEDULE
BAR SIZE #3 #4 #5 #6 #7 #8 #9 #10 #11
TOP BAR* 1'-6" 2'-2" 2'-8" 3'-3" 4'-8" 5'-2" 5'-10" 6'-6" 7'-2"
OTHER 1'-3" 1'-8" 2'-1" 2'-6" 3'-6" 4'-0" 4'-6" 5'-0" 5'-6"
SITE
SEMINOLE TRIBE OF FLORIDA
PUBLIC WORKS DEPARTMENT
CONTACT TWO (2) BUSINESS DAYS BEFORE DIGGING
HTTP://TED.SEMTRIBE.COM/FORMS-LIBRARY
DIGPUBLICWORKS@SEMTRIBE.COM
(954) 894-1060 - EXT. 10910
PROJ
DATE
SHEET
DWG N/A
1 2 3 4 5 6
A
B
C
D
C O
M M
U N
IT
Y
PL
AN
N
IN
G
D
EV
EL
O
PM
EN
T
SE
M
IN
O
LE
T R
IB
E
O F
FL
O
R
ID
A
G
R
IF
FI
N
R D
D
AV
IE
, F L
PH
(9
) 9
-6
Know what's Call before you dig.
below.
D
RR
EV
IS
IO
N
C H
K
BY
AP
VD
EN
G
R
SE
AL
D
AT
E N
O
JM
P
R M
JM
P
JM
P
12802 Tampa Oaks Boulevard, Suite 110 Tampa, Florida 33637 | FL CA 27801
P: (813) 355-0096 | www.GM2inc.com
THE FUTURE OF ENGINEERING COLLABORATION
N N ob H ill R oa d, S ui te
Su nr is e, F lo rid a
.4
.6
C
L
B7
En gi ne er s P la nn er s
S ur ve yo rs H
S Q
G R
O U
P , L
LC
BID SET
G
EN
ER
AL
N O
TE
S
42590.00
07/25/2025
S-1.0
B
IG
C Y
P R
E S
S R
E -P
U M
P S
T A
T
IO
N
SEMINOLE TRIBE OF FLORIDA RE-PUMP STATION - CANOPY FOUNDATION
32051 W BOUNDARY RD, CLEWISTON, FL 33440
N.T.S.1 LOCATION
#14 AND #18 10db
#9 TO #11 8db180-DEGREE
HOOK
#3 TO #8 6db
GREATER OF
4db AND 2.5
IN
#14 AND #18 10db
#9 TO #11 8db90-DEGREE
HOOK
#3 TO #8 6db
12db
TYPE OF
STANDARD
HOOK
BAR SIZE
MIN. INSIDE
BEND DIA.
(IN)
STRAIGHT
EXTENSION
(IN) - Lext
TYPE F STANDARD HOOK
STANDARD HOOK GEOMETRY FOR DEVELOPMENT OF DEFORMED BARS IN TENSION
#6 TO #8 6db
180-DEGREE
HOOK
#3 TO #5 4db GREATER OF 4db AND 2.5
IN
#6 TO #8 6db
135-DEGREE
HOOK
#3 TO #5 4db GREATER OF 6db AND 3 IN
#6 TO #8 6db 12 db
90-DEGREE
HOOK
#3 TO #5 4db GREATER OF 6db AND 3 IN
TYPE OF
STANDARD
HOOK
BAR SIZE
MIN. INSIDE
BEND DIA.
(IN)
STRAIGHT
EXTENSION
(IN) - Lext
TYPE F STANDARD HOOK
MIN. INSIDE BEND DIAMETER AND STANDARD HOOK GEOMETRY FOR STIRRUPS, TIES AND
HOOPS
EXIST. 5' HIGH
CHAIN-LINK FENCE
EXIST. CANOPY & ALL
SUPPORT POLES TO
BE REMOVED
EXIST. CONTAINER TO
BE REMOVED
EXIST. CURB
EXIST.
METER
EXIST. VALVE PIT
EXIST. VALVE PIT
EXIST. CANOPY & ALL
SUPPORT POLES TO
BE REMOVED
EXIST. CONTAINER TO
BE REMOVED
EXIST.
BUILDING
EXIST. ASPHALT
EXIST. ASPHALT
EXIST. STORMWATER
RETENTION AREA
EXIST. STORMWATER
RETENTION AREA
NEW COLD-FORMED STEEL
CANOPY STRUCTURE. REFER TO
ALLIANCE ENGINEERING CANOPY
DRAWINGS
NEW CONCRETE
FOOTINGS WITH PEDESTAL
ASPHALT FLOOR.
REFER TO CIVIL PLANS
NEW CONCRETE
FOOTINGS WITH PEDESTAL
NEW COLD-FORMED STEEL
CANOPY STRUCTURE. REFER TO
ALLIANCE ENGINEERING CANOPY
DRAWINGS
30' - 0"
30' - 0"
ASPHALT AS PER CIVIL PLANS
HATCH LEGEND
NEW CONCRETE FOUNDATION
CANOPY STRUCTURE AREA
SEMINOLE TRIBE OF FLORIDA
PUBLIC WORKS DEPARTMENT
CONTACT TWO (2) BUSINESS DAYS BEFORE DIGGING
HTTP://TED.SEMTRIBE.COM/FORMS-LIBRARY
DIGPUBLICWORKS@SEMTRIBE.COM
(954) 894-1060 - EXT. 10910
PROJ
DATE
SHEET
DWG N/A
1 2 3 4 5 6
A
B
C
D
C O
M M
U N
IT
Y
PL
AN
N
IN
G
D
EV
EL
O
PM
EN
T
SE
M
IN
O
LE
T R
IB
E
O F
FL
O
R
ID
A
G
R
IF
FI
N
R D
D
AV
IE
, F L
PH
(9
) 9
-6
Know what's Call before you dig.
below.
D
RR
EV
IS
IO
N
C H
K
BY
AP
VD
EN
G
R
SE
AL
D
AT
E N
O
JM
P
R M
JM
P
JM
P
12802 Tampa Oaks Boulevard, Suite 110 Tampa, Florida 33637 | FL CA 27801
P: (813) 355-0096 | www.GM2inc.com
THE FUTURE OF ENGINEERING COLLABORATION
N N ob H ill R oa d, S ui te
Su nr is e, F lo rid a
.4
.6
C
En gi ne er s P la nn er s
S ur ve yo rs H
S Q
G R
O U
P , L
LC
BID SET
SI
TE
P
LA
N
42590.00
07/25/2025
S-1.1
B
IG
C Y
P R
E S
S R
E -P
U M
P S
T A
T
IO
N
1" = 10'-0"1 SITE PLAN N
KEY NOTE:
BOTH NORTH AND SOUTH CANOPIES STRUCTURES ARE
IDENTICAL AND SHARE THE SAME DESIGN.
A
A
B
B
C
C
1 1
2 2
ASPHALT FLOOR.
REFER TO CIVIL
DRAWINGS
S-2.0
FT-1FT-1
FT-1FT-1
6 "
REFER TO ALLIANCE
ENGINEERING CANOPY
DRAWINGS. CONTRACTOR TO
MATCH CENTER OF COLUMNS
WITH CENTER OF PEDESTALS
CANOPY COLUMNS.
REFER TO ALLIANCE
ENGINEERING CANOPY
DRAWINGS
15' - 0" 15' - 0"
30' - 0"
FT-1
FT-1
5' - 0" 5'
0"
ASPHALT FLOOR AS PER CIVIL DRAWINGS
HATCH LEGEND
NEW CONCRETE FOUNDATION
2'
0" 1'
4"
5' - 0"
18 "
CANOPY COLUMNS.
REFER TO ALLIANCE
ENGINEERING CANOPY
DRAWINGS
CONC. FOOTING FT-1
W/ #5 @ 8" O.C. EACH
WAY, TOP & BOTTOM
ASPHALT FLOOR.
REFER TO CIVIL
PLANS
18"x18" CONC.
PEDESTAL
18 "
18"x18" CONC.
PEDESTAL W/ (12) #5
VERT. & STIRRUPS #3
@ 8" O.C. AS SHOWN
T.O.F.F.
0' - 0"
A B C
T.O. FOUNDATION
-2' - 0"
CANOPY COLUMNS.
REFER TO ALLIANCE
ENGINEERING CANOPY
DRAWINGS
CONC. FOOTING FT-1
W/ #5 @ 8" O.C. EACH
WAY, TOP & BOTTOM
ASPHALT FLOOR.
REFER TO CIVIL
PLANS
18"x18" CONC.
PEDESTAL
CANOPY COLUMNS.
REFER TO ALLIANCE
ENGINEERING CANOPY
DRAWINGS
CANOPY COLUMNS.
REFER TO ALLIANCE
ENGINEERING CANOPY
DRAWINGS
CONC. FOOTING FT-1
W/ #5 @ 8" O.C. EACH
WAY, TOP & BOTTOM
18"x18" CONC.
PEDESTAL CONC. FOOTING FT-1
W/ #5 @ 8" O.C. EACH
WAY, TOP & BOTTOM
18"x18" CONC.
PEDESTAL
ASPHALT FLOOR.
REFER TO CIVIL
PLANS
30' - 0"
5' - 0"
15' - 0"15' - 0"
5' - 0"5' - 0"
1'
4"
1'
4"
1'
4"
18 " 18 " 18 "
ASPHALT FLOOR.
REFER TO CIVIL
PLANS
ASPHALT FLOOR.
REFER TO CIVIL
PLANS
T.O.F.F.
0' - 0"
1 2
T.O. FOUNDATION
-2' - 0"
CANOPY COLUMNS.
REFER TO ALLIANCE
ENGINEERING CANOPY
DRAWINGS
ASPHALT FLOOR.
REFER TO CIVIL
PLANS
CONC. FOOTING FT-1
W/ #5 @ 8" O.C. EACH
WAY, TOP & BOTTOM
18"x18" CONC.
PEDESTAL
18"x18" CONC.
PEDESTAL
25' - 0"
5' - 0"
1'
4"
1'
4"
5' - 0"
CANOPY COLUMNS.
REFER TO ALLIANCE
ENGINEERING CANOPY
DRAWINGS18 " 18 "
CONC. FOOTING FT-1
W/ #5 @ 8" O.C. EACH
WAY, TOP & BOTTOM
SEMINOLE TRIBE OF FLORIDA
PUBLIC WORKS DEPARTMENT
CONTACT TWO (2) BUSINESS DAYS BEFORE DIGGING
HTTP://TED.SEMTRIBE.COM/FORMS-LIBRARY
DIGPUBLICWORKS@SEMTRIBE.COM
(954) 894-1060 - EXT. 10910
PROJ
DATE
SHEET
DWG N/A
1 2 3 4 5 6
A
B
C
D
C O
M M
U N
IT
Y
PL
AN
N
IN
G
D
EV
EL
O
PM
EN
T
SE
M
IN
O
LE
T R
IB
E
O F
FL
O
R
ID
A
G
R
IF
FI
N
R D
D
AV
IE
, F L
PH
(9
) 9
-6
Know what's Call before you dig.
below.
D
RR
EV
IS
IO
N
C H
K
BY
AP
VD
EN
G
R
SE
AL
D
AT
E N
O
JM
P
R M
JM
P
JM
P
12802 Tampa Oaks Boulevard, Suite 110 Tampa, Florida 33637 | FL CA 27801
P: (813) 355-0096 | www.GM2inc.com
THE FUTURE OF ENGINEERING COLLABORATION
N N ob H ill R oa d, S ui te
Su nr is e, F lo rid a
.4
.6
C
En gi ne er s P la nn er s
S ur ve yo rs H
S Q
G R
O U
P , L
LC
BID SET
FO
U
N D
AT
IO
N P
LA
N
AN
D
D
ET
AI
LS
42590.00
07/25/2025
S-2.0
B
IG
C Y
P R
E S
S R
E -P
U M
P S
T A
T
IO
N
FBC 2023, 8TH EDITION
OPEN BUILDING
GCpi +/- = 0.00
RISK CATEGORY = II
EXPOSURE CATEGORY = c
W…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .