The document is a Cost Proposal Attachment A for Motor Repair and Rewinding Services for the City of St. Petersburg, Florida. The comprehensive spreadsheet details an extensive inventory of 72 electric motors located across multiple municipal facilities including Cosme Water Treatment Plant (WTP), Lift Stations, NEWRF, NWWRF, SWWRF, Oberly, Washington Terrace, and other sites. The motors vary in specifications including horsepower (ranging from 20 to 1000 hp), voltage (230/460 to 4160), and are manufactured by brands such as Baldor/Reliance, Westinghouse, GE, Marathon, and others. The document appears to be a detailed pricing template for motor repair and rewinding services, with the intent of establishing unit pricing for mechanical and electrical motor repairs across the city's infrastructure.
The cost proposal includes a breakdown for each motor's location, manufacturer, specifications, and quantity, with columns for mechanical and electrical unit pricing. Notably, all prices are currently listed as $0, suggesting this is a template for vendors to complete. The document includes supplemental pricing sections for emergency repair charges, inspection fees, core restocking, additional parts, machine work, and hourly rates. Special notes indicate that babbitt bearing costs, bearing extension costs, and core replacement will be invoiced separately, and the city will pay for crane services. The pricing structure allows for flexibility in repair and maintenance services across the city's diverse motor inventory, with provisions for various unexpected repair scenarios and additional work not initially specified in the primary pricing schedule.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Motor_Repair_and_Rewinding_Services.pdf | ||
| Agreement.docx | DOCX document | |
| Attachment_B_-_Specifications,_Non-Inverter_Duty_Motors_2024.doc | DOC document | |
| Attachment_C_-_Specifications,_Inverter_Duty_Motors_2024.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Note: All motors are Totally Enclosed Fan-Cooled (TEFC) unless otherwise stated. | ||||||||||||||||
| Line | ||||||||||||||||
| No. | Site Location | Motor Location | Manufacturer | Horse-Power (hp) | Voltage | Current Rating (amps) | Rpm | Frame Size | Vertical (V) or Horizontal (H) | Quantity | Unit Price | |||||
| Mechanical | Unit Price | |||||||||||||||
| Electrical | Total | |||||||||||||||
| Unit Price (Mechanical + Electrical) | Extended | |||||||||||||||
| Price (Quantity x Total Unit Price) | Notes. State here if motor is other than TEFC or is a special build | |||||||||||||||
| 1 | Cosme WTP | Fulshing Pump Motor 1 | Baldor/Reliance | 40 | 230/460 | 96/48 | 1775 | 324HM | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 2 | Cosme WTP | Fulshing Pump Motor 2 | Baldor/Reliance | 40 | 230/460 | 96/48 | 1775 | 324HM | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 3 | Cosme WTP | Fulshing Pump Motor 3 | Baldor/Reliance | 40 | 230/460 | 96/48 | 1775 | 324HM | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 4 | Cosme WTP | High Service Pump 1 | Westinghouse | 40 | 440 | 58.5 | 695 | 504U | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 5 | Cosme WTP | High Service Pump 2 | Westinghouse | 50/90/360/700 | 2300 | 359/447/715/892 | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||||
| 6 | Cosme WTP | High Service Pump 3 | Westinghouse | 50/90/360/700 | 2300 | 359/447/715/892 | 581-S | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | |||
| 7 | Cosme WTP | High Service Pump 4 | Westinghouse | 50/90/360/700 | 2300 | 359/447/715/892 | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||||
| 8 | Cosme WTP | High Service Pump 5 | Westinghouse | 200 | 2300 | 43.6 | 1180 | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | |||
| 9 | Cosme WTP | High Service Pump 7 | Westinghouse | 75 | 2300 | 105 | 590 | 581-S | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 10 | Cosme WTP | High Service Pump 8 | The Electric Products Co, Cleveland | 1000 | 2300 | 226/454 | 705 | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | |||
| 11 | Cosme WTP | High Service Pump 9 | The Electric Products Co, Cleveland | 1000 | 2300 | 226/454 | 705 | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | |||
| 12 | Cosme WTP | Sludge Pump 1 | Baldor/Reliance | 40 | 230/460 | 48/24 | 1770 | 256T | V | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 13 | Cosme WTP | Sludge Pump 2 | Baldor/Reliance | 40 | 230/460 | 48/24 | 1770 | 256T | V | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 14 | Cosme WTP | Sludge Pump 3 | Baldor/Reliance | 40 | 230/460 | 48/24 | 1770 | 256T | V | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 15 | Lift Station Location | LS61 | Continental Electric | 150 | 460 | 202 | 875 | SNV585P | V | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | Converted to Inverter Duty | |
| 16 | Lift Station Location | LS35 | ALLIS CHALMERS | 50 | 460 | 77 | 1175 | 250 | V | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | TEFC | |
| 17 | NEWRF | Filter Feed | GE | 60 | 460 | 81.1 | 590 | L445TP24 | V | 3 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 18 | NEWRF | Aerator Blowers | Marathon | 200 | 460 | 224 | 1800 | 447 | H | 4 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 19 | NEWRF | Backwash | GE | 150 | 460 | 185 | 710 | B509TP30 | V | 3 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 20 | NEWRF | New RAS | Siemens | 50 | 460 | 67 | 886 | 404T | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 21 | NEWRF | New RAS | GE | 50 | 460 | 64 | 405TS | H | 2 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | |||
| 22 | NEWRF | Transfer station | GE | 25 | 460 | 35 | 1150 | K236TP16 | V | 3 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 23 | NEWRF | New WAS | Baldor | 30 | 460 | 36 | 1765 | 286T | H | 2 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 24 | NEWRF | New WAS | Siemens | 30 | 460 | 34.5 | 1775 | 326U | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 25 | NEWRF | Old Influent | US Motor | 50 | 460 | 65 | 900 | A44411P | V | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 26 | NEWRF | Old Influent | Marathon | 50 | 460 | 65 | 892 | 444 HPV | V | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 27 | NEWRF | Old Aeration | US Motor | 100 | 460 | 119 | 1770 | 447VP | V | 2 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 28 | NEWRF | RAS Clar.5 | US Motor | 40 | 460 | 105 | 880 | 365VPZ | V | 2 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 29 | NEWRF | Distribution | GE | 500 | 2300 | 115 | 1180 | 6336P30 | V | 3 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 30 | NEWRF | Distribution | US Motor | 500 | 2300 | 115 | 1185 | 5810PWPI | V | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 31 | NWWRF | Distribution | US Motors/NIDEC | 400 | 460 | 470 | 1190 | 5807ZVP | V | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | Inverter duty | |
| 32 | NWWRF | Distribution | US Motors/NIDEC | 150 | 460 | 172 | 1190 | 449ZPZ | V | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | Inverter Duty | |
| 33 | NWWRF | Intermediate Pumps | BMR | 125 | 460 | 900 | 447V | V | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | |||
| 34 | NWWRF | Intermediate Pumps | BMR | 200 | 460 | 900 | 5800V | V | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | |||
| 35 | NWWRF | Aeration blowers | Reliance electric | 250 | 460 | 275 | 3600 | 449TS | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 36 | NWWRF | Aeration blowers | WEG | 250 | 460 | 266 | 3600 | 445/7TS | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 37 | NWWRF | Mechanical mixers(aeration) | 100 | 460 | V | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||||||
| 38 | Oberly | HSP1 | US MOTOR/Emerson | 600 | 4000 | 80 | 1185 | 5012MS | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | SWGR | |
| 39 | Oberly | HSP2 | US MOTOR/Emerson | 600 | 4000 | 80 | 1185 | 5012MS | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | SWGR | |
| 40 | Oberly | HSP3 | US MOTOR/Emerson | 600 | 4000 | 80 | 1185 | 5012MS | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | SWGR | |
| 41 | Oberly | HSP4 | US MOTOR/Emerson | 600 | 4000 | 80 | 1185 | 5012MS | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | SWGR | |
| 42 | Oberly | HSP5 | US MOTOR/Emerson | 600 | 4000 | 80 | 1185 | 5012MS | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | SWGR | |
| 43 | SWWRF | Distribution | US Motor/NIDEC | 250 | 460 | 313 | 1185 | 447TPB | V | 5 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 44 | SWWRF | Distribution | GE | 450 | 460 | N/A | 887 | 8337P30 | V | 2 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 45 | SWWRF | Backwash | US Motors/NIDEC | 500 | 460 | 638 | 711 | 5813P | VHS | 3 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 46 | SWWRF | (2) DIGESTER (1) RECIRC | BALDOR | 40 | 460 | 46 | 1770 | 324TC | H | 3 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 47 | SWWRF | (2) DIGESTER (2) RECIRC | BALDOR | 50 | 460 | 57 | 1770 | 326TC | H | 3 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 48 | SWWRF | THERMO HEX HOT PUMP | BALDOR | 25 | 460 | 30 | 1770 | 284T | H | 2 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 49 | SWWRF | MESO HEX COLD WATER PUMP | BALDOR | 25 | 460 | 30 | 1770 | 284T | H | 2 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 50 | SWWRF | PRIMARY SCUM PUMP | BALDOR | 20 | 460 | 23.1 | 1760 | 256TC | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 51 | SWWRF | PRIMARY SLUDGE PUMP | BALDOR | 20 | 460 | 23.1 | 1760 | 256TC | H | 3 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 52 | SWWRF | BLOWER #1 | TEAM | 50 | 460 | 56 | 1765 | 326T | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 53 | SWWRF | BLOWER #2 | ALLIANCE | 50 | 460 | 56 | 1765 | 326T | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 54 | SWWRF | SLUDGE FEED PUMP | BALDOR | 20 | 460 | 23.1 | 1760 | 256TC | H | 3 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 55 | SWWRF | THICKENED SLUDGE PUMP | BALDOR | 25 | 460 | 30 | 1770 | 284TC | H | 2 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 56 | SWWRF | CLARIFIER 2 + 1 RAS | NEMA | 75 | 460 | 95 | 890 | N/A | V | 3 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 57 | SWWRF | D1 MIXER | TEXP | 20 | 460 | 23.6 | 1765 | 256T | V | 4 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 58 | SWWRF | D2 MIXER | TEXP | 20 | 460 | 24.3 | 1160 | 286T | V | 4 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 59 | SWWRF | FOUL AIR FAN | BALDOR | 40 | 460 | 48 | 1175 | 324T | H | 2 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 60 | SWWRF | BUS | TEXP | 75 | 460 | 83 | 1775 | 365T | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 61 | SWWRF | BUS | TEXP | 150 | 460 | 165 | 1783 | 445T | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 62 | SWWRF | BATCH TANK DISCHARGE | BALDOR | 20 | 460 | 23.1 | 1760 | 256TC | H | 2 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 63 | SWWRF | CLARIFIER 3 RAS | NIDEC | 50 | 460 | 67 | 890 | 404T | H | 3 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 64 | SWWRF | AERATION MIXER | MARATHON | 25 | 460 | 32.5 | 1182 | 324T | H | 2 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 65 | SWWRF | HOT WATER RETURN | BALDOR | 20 | 460 | 24 | 1765 | 256JM | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 66 | SWWRF | FOG 1 | BALDOR | 40 | 460 | 46 | 1770 | 324TC | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 67 | SWWRF | FOG 2 | BALDOR | 30 | 460 | 460 | 36 | 1770 | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||
| 68 | Washington Terrace | HSP1 | Reliance | 300 | 4160 | 38 | 1183 | 24EC5010Z | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | VFD | |
| 69 | Washington Terrace | HSP2 | Reliance | 300 | 4160 | 38 | 1183 | 24EC5010Z | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | RVSS | |
| 70 | Washington Terrace | HSP3 | Reliance | 600 | 4160 | 75 | 1168 | 26EC5810S | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | RVSS | |
| 71 | Washington Terrace | HSP4 | Reliance | 600 | 4160 | 75 | 1168 | 26EC5810S | H | 1 | $ - 0 | $ - 0 | $ - 0 | $ - 0 | VFD | |
| Total | $ - 0 | $ - 0 | $ - 0 | $ - 0 | ||||||||||||
| Total Price: | $ - 0 | |||||||||||||||
| Note: Babbitt bearing cost, bearing extension cost and rewinding core re-stacking or core replacement costs, if necessary, shall be added to the invoice and not to the | ||||||||||||||||
| unit pricing above. City shall pay any costs associated with cranes. | ||||||||||||||||
| Supplemental Pricing (for items and services not specified above): | ||||||||||||||||
| 64 | Emergency Repair Charge (multiplier for total unit price) = Percent upcharge | % | ||||||||||||||
| 65 | Inspection Fee (when repair is not made) | $ | ||||||||||||||
| 66 | Rewinding core re-stocking Fee | $ | ||||||||||||||
| 67 | Additional Parts not covered in bid % + off - manufacturer's list price | % | ||||||||||||||
| 68 | Machine Work per hour | $ | ||||||||||||||
| 69 | Emergency Machine Work per hour | $ | ||||||||||||||
| 70 | Additional Hourly Rate for items not covered in bid per hour | $ | ||||||||||||||
| 71 | Additional Emergency Hourly Rate for items not covered in bid per hour | $ | ||||||||||||||