This is a construction plans document for the Old Bridge Park Public Use Facilities project prepared by Cummins | Cederberg Coastal & Marine Engineering for Palm Beach County, Florida, dated March 4, 2026. The project involves the construction of a fixed dock facility with public use amenities at Old Bridge Park, located along the Intracoastal Waterway in Lake Worth, Florida. The scope of work includes demolition of three existing 14-inch square concrete piles, construction of a new fixed dock measuring 105 feet long by 25 feet wide with a total overwater footprint of 801 square feet, installation of 24 new 14-inch square prestressed concrete piles with a minimum 5-foot embedment into rock, installation of black locust decking on wood framing, construction of safety ladders, installation of vertical rubber fenders, and concrete repairs to the existing bulkhead cap. The plans consist of 10 sheets including cover sheet, existing and demolition plans, proposed site plan, geotechnical boring information, dock framing and sections, dock details, railing details, and concrete repair specifications.
The design follows the Florida Building Code 2023, ASCE 7-22, and ACI 318-19 standards with wind design criteria of 155 mph ultimate velocity and 120 mph allowable stress design velocity. Concrete piles shall achieve a minimum 28-day compressive strength of 6,000 PSI and comply with FDOT Class-V specifications, with a service capacity of 10 tons in compression, 2 tons in tension, and 1 ton in lateral loads. The fixed dock is designed for a 100 PSF live load and a design vessel size of 30 feet with occupied wind speed of 40 mph. The dock deck elevation is set at +3.6 feet NAVD with pile tip elevations at -13.0 feet NAVD. Contractor responsibilities include obtaining all required permits and approvals before commencing work, performing field surveys and as-built documentation by a Florida-registered surveyor, locating all utilities through Sunshine Call 811, hiring an independent geotechnical engineer for pile driving inspection and vibration monitoring of the adjacent bridge, and restoring all access and staging areas to pre-construction conditions at the contractor's expense. Materials specifications include pressure-treated Southern Pine lumber complying with AWPA UC4B standards, black locust 5/4" x 6" decking dried for exterior use and meeting ASTM C1028 ADA slip resistance requirements, and stainless steel Type 316 marine-grade hardware for all bolts and components.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AS
N
O
TE
D
D
AT
E:
SC
AL
E:
D R
AW
N
C H
EC
KE
D
AP
PR
O
VE
D
PR
OJ
EC
T:
SHEET:
J:
\P ro je ct s\
PB
C O ld B rid ge
P ar k\ D ra w in gs
\W or ki ng
\(2
6-
-0 4)
P
PB
C
O ld
B rid ge P ar k.
dw g
D
AT
E:
/4 /2
IN
TR
AC
O
AS
TA
L
PO
IN
T, S U
IT
E
JU
PI
TE
R
, F
LO
R
ID
A
PH
O
N E:
W W
W .C
U M
M
IN
SC
ED
ER
BE
R G
.C O
M C
O A
C U
M M
IN
S
C
E D
E R
B E
R G
C oa st al
M ar in e E ng in ee ri ng
PU
BL
IC
U
SE
F
AC
IL
IT
IE
S
3/ 4/
JD
R
O
LD
B R
ID
G
E
PA
R K
C
O
VE
R S
H
EE
T
JP
C
M G
FE
D
ER
AL
H W
Y
A T
L A
N T
I
E
A N
IN
TR
A C
O
AS
TA
L
W
AT
ER
W
AY
FL
O
R
ID
A M
AN
G
O R
D
LAKE AVE.
LUCERNE AVE.
JEWELL COVE
OLD BRIDGE PARK
PROJECT LOCATION
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY JORDON P. CHEIFET
ON THE DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
JORDON P. CHEIFET
FL P.E No. 72876
PROJECT LOCATION
AutoCAD SHX Text
(561) 233-2400
AutoCAD SHX Text
ENVIRONMENTAL RESOURCES MANAGEMENT
AutoCAD SHX Text
PALM BEACH COUNTY
AutoCAD SHX Text
DEPARTMENT OF
AutoCAD SHX Text
WEST PALM BEACH, FLORIDA 33411
AutoCAD SHX Text 2300 NORTH JOG ROAD, 4th FLOOR
AutoCAD SHX Text
OLD BRIDGE PARK PUBLIC USE FACILITIES
AutoCAD SHX Text
STATE OF FLORIDA
AutoCAD SHX Text
COUNTY OF PALM BEACH
AutoCAD SHX Text
INDEX OF DRAWINGS
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
EXISTING AND DEMOLITION PLAN
AutoCAD SHX Text
BOARD OF COUNTY COMMISSIONERS
AutoCAD SHX Text
MARIA SACHS
AutoCAD SHX Text
DISTRICT 5
AutoCAD SHX Text
JOEL G. FLORES
AutoCAD SHX Text
DISTRICT 3
AutoCAD SHX Text
BOBBY POWELL JR.
AutoCAD SHX Text
DISTRICT 7
AutoCAD SHX Text
MARIA G. MARINO
AutoCAD SHX Text
DISTRICT 1
AutoCAD SHX Text
PROPOSED SITE PLAN
AutoCAD SHX Text
GEOTECHINCAL BORINGS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SARA BAXTER, MAYOR
AutoCAD SHX Text
DISTRICT 6
AutoCAD SHX Text
MARCI WOODWARD
AutoCAD SHX Text
VICE MAYOR
AutoCAD SHX Text
DISTRICT 4
AutoCAD SHX Text
GREGG K. WEISS
AutoCAD SHX Text
DISTRICT 2
AutoCAD SHX Text
CITY OF LAKE WORTH
AutoCAD SHX Text
DOCK FRAMING & SEC.
AutoCAD SHX Text
AutoCAD SHX Text
DOCK DETAILS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RAILING DETAILS
AutoCAD SHX Text
CONC. REPAIRS
AutoCAD SHX Text
DOCK DETAILS
AutoCAD SHX Text
O
TE
D
D
AT
E:
SC
AL
E:
D R
AW
N
C H
EC
KE
D
AP
PR
O
VE
D
PR
OJ
EC
T:
SHEET:
J:
\P ro je ct s\
PB
C O ld B rid ge
P ar k\ D ra w in gs
\W or ki ng
\(2
6-
-0 4)
P
PB
C
O ld
B rid ge P ar k.
dw g
D
AT
E:
/4 /2
IN
TR
AC
O
AS
TA
L
PO
IN
T, S U
IT
E
JU
PI
TE
R
, F
LO
R
ID
A
PH
O
N E:
W W
W .C
U M
M
IN
SC
ED
ER
BE
R G
.C O
M C
O A
C U
M M
IN
S
C
E D
E R
B E
R G
C oa st al
M ar in e E ng in ee ri ng
PU
BL
IC
U
SE
F
AC
IL
IT
IE
S
3/ 4/
JD
R
O
LD
B R
ID
G
E
PA
G
EN
ER
AL
N
O
TE
S
JP
C
M G
0.0' NAVD
MLW LINE
MHW LINE
0.10'
-2.36'
VERTICAL DATUM
Station ID 8722654
NOT TO SCALE
GENERAL NOTES:
1. THE WORK CONSISTS OF PROVIDING ALL CONSTRUCTION, LABOR, EQUIPMENT, MATERIAL AND OPERATIONS IN
CONNECTION WITH IMPROVEMENTS AS SHOWN ON THESE DRAWINGS.
2. IT IS THE INTENT OF THESE PLANS TO BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION. ANY DISCREPANCIES IN THE PLANS WITH THE FIELD CONDITIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ENGINEER. CONSTRUCTION SHALL NOT CONTINUE UNTIL THE ENGINEER HAS
ADDRESSED THE DISCREPANCIES.
3. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PROTECT EXISTING STRUCTURES IN THE PROJECT VICINITY. ANY DAMAGE TO PRIVATE OR PUBLIC PROPERTY WITHIN THE PROJECT VICINITY, INCLUDING STAGING SITES, WORK AND ACCESS AREAS SHALL BE REPAIRED PROMPTLY BY THE CONTRACTOR. ANY DAMAGE AS A RESULT OF THE CONTRACTOR'S OPERATIONS SHALL BE REPAIRED AT NO COST TO THE OWNER. ALL ACCESS AND STAGING AREAS SHALL BE KEPT NEAT, ORDERLY AND IN A SAFE MANNER. ALL ACCESS AND STAGING AREAS SHALL BE RESTORED TO THE PRE-CONSTRUCTION CONDITION UPON PROJECT COMPLETION AT THE COST OF THE CONTRACTOR. THE SITE SHALL BE RESTORED BY REMOVING AND FINISHING ALL EVIDENCE FOR CONSTRUCTION. IN THE EVENT INFRASTRUCTURE (SUCH AS WALKWAYS, SIDEWALKS, FENCES, VEGETATION, ETC.) IS TEMPORARILY REMOVED OR RELOCATED OR THERE IS UNAUTHORIZED DAMAGE TO VEGETATION AND/OR FACILITIES BY THE CONTRACTOR, THE CONTRACTOR SHALL RESTORE ALL DAMAGE TO STRUCTURES AND NATURAL FEATURES TO PRE-CONSTRUCTION CONDITIONS OR BETTER. REFER TO SECTION 108.2 OF FDOT'S STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE
CONSTRUCTION.
4. UTILITIES ARE NOT SHOWN IN THE PLANS. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL PRESENT UTILITIES
PRIOR TO CONSTRUCTION.
5. CONTRACTOR IS RESPONSIBLE FOR PROVIDING PROPER CLEARANCE AND PROTECTION TO ALL OVERHEAD WIRES AND
OBSTRUCTIONS.
6. THE CONTRACTOR SHALL EXCLUDE THE PUBLIC FROM THE WORK AREAS IN THE IMMEDIATE VICINITY OF OPERATIONS.
CONTRACTOR SHALL PROVIDE APPROPRIATE SAFETY MEASURES TO PROTECT THE PUBLIC.
7. ALL NEW STRUCTURAL WORK INCLUDING CONCRETE AND REINFORCEMENT SHALL BE ACCURATELY FIELD MEASURED AND DIMENSIONS VERIFIED BY THE CONTRACTOR PRIOR TO ORDERING MATERIALS. CONTRACTOR SHALL BE PREPARED TO MAKE FIELD ADJUSTMENTS TO ACCURATELY FIT THE NEW WORK TO EXISTING CONDITIONS.
8. NO CONSTRUCTION SHALL COMMENCE UNTIL ALL REQUIRED PERMITS AND APPROVALS HAVE BEEN SECURED AND THE
CONTRACTOR HAS BEEN ISSUED NOTICE TO PROCEED.
9. ATTENTION IS DIRECTED TO THE FACT THAT THESE PLANS MAY HAVE BEEN CHANGED IN SIZE BY REPRODUCTION. THIS
SHOULD BE CONSIDERED WHEN OBTAINING SCALED DATA.
10. CONSTRUCTION WORK SHALL BE EXECUTED IN ACCORDANCE WITH ALL LOCAL, STATE, AND NATIONAL BUILDING CODES AND GOVERNING REGULATIONS INCLUDING THOSE OF FDEP, USACE, AND PALM BEACH COUNTY. CONTRACTOR
SHALL ADHERE TO ALL CONDITIONS OF THE PERMITS AND EXEMPTIONS.
11. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE TEMPORARY SUPPORT FOR MARINE STRUCTURES &
SHORELINE DURING CONSTRUCTION.
DEMOLITION:
1. CONTRACTOR SHALL VERIFY THE EXTENTS, LOCATION AND QUANTITIES OF EXISTING ELEMENTS TO BE REMOVED.
2. ALL DEBRIS WITHIN THE LIMITS OF THE PROJECT SHALL BE HAULED OFF SITE BY THE CONTRACTOR, AS DIRECTED BY
THE OWNER, AND DISPOSED OF AT AN APPROPRIATE FACILITY.
3. CONTRACTOR SHALL NOT DAMAGE ANY STRUCTURAL COMPONENTS BEYOND THE DEMOLITION REQUIREMENTS DEPICTED IN THESE DRAWINGS. ANY DAMAGE SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE.
DESIGN CRITERIA:
1. WIND DESIGN PER ASCE 7-22
VELOCITY ULT = 155MPH
VELOCITY ASD = 120MPH
RISK CATEGORY 1
EXPOSURE : "D"
KZT = 1.0
KD = 0.85
G = 0.85
2. DESIGN CODE: FLORIDA BUILDING CODE 2023, ASCE 7-22, ACI 318-19, NDS 2018
3. FIXED DOCK:
LL = 100 PSF
MAXIMUM WIND SPEED UNOCCUPIED = 155 MPH (54 PSF)
DESIGN VESSEL SIZE = 30 FEET
OCCUPIED WIND SPEED = 40 MPH
4. CONCRETE PILE SERVICE CAPACITY:
COMPRESSION: 10 T
TENSION: 2 T
LATERAL: 1 T
5. DESIGN SERVICE LIFE OF EXISTING TO REMAIN CONCRETE PILES IS ESTIMATED AT 20-30 YEARS.
CONCRETE PILE:
1. CONCRETE PILES SHALL BE SQUARE PRESTRESSED CONCRETE PILES WITH 0.5'' DIAMETER STRANDS, GRADE 270 KSI, LRS.
2. CONCRETE SHALL ACHIEVE MIN. 28-DAY COMPRESSIVE STRENGTH OF 6,000 PSI, AND FOLLOW FDOT CLASS-V SPECIFICATIONS. MINIMUM CONCRETE COVER TO INTERNAL REINFORCEMENT SHALL BE 3'' ON ALL SIDES.
3. CONTRACTOR TO DRIVE CONCRETE PILING IN ACCORDANCE WITH FDOT 455-7.
4. PILES SHALL ACHIEVE A MINIMUM OF 5 FEET OF EMBEDMENT INTO ROCK LAYER. CONTRACTOR SHALL BE PREPARED TO PREPUNCH OR PREDRILL HOLES AS NECESSARY TO ACHIEVE EMBEDMENT. IF PILE HOLES ARE UTILIZED, THE PILES SHALL BE DRIVEN THE FINAL 3 FEET. REFER TO GEOTECHINCAL REPORT FOR ANTICIPATED LIMESTONE LAYERS.
5. EXISTING TO REMAIN PILES ARE CONFIRMED TO HAVE MINIMUM 5 FEET OF EMBEDMENT INTO ROCK LAYER PER
GEOTECHNICAL REPORT.
6. DOCK PILES TO SUPPORT A MINIMUM LATERAL LOAD OF 2 KIPS AT EL=+3.6 FT-NAVD.
7. TOP OF DOCK PILE ELEVATION SHALL BE AS SHOWN IN PLANS HEREIN.
8. PILES SHALL BE CUT OFF AT ELEVATIONS SHOWN IN THE PLANS AND SECTIONS HEREIN ONLY AFTER ENGINEER APPROVAL. MINIMUM PILE TIP ELEVATION SHALL BE -13'.0 WITH MIN 5' EMBEDMENT INTO ROCK AS SHOWN ON PLANS.
NOTIFY ENGINEER IF PRACTICAL REFUSAL IS ENCOUNTERED PRIOR TO SPECIFIED TIP.
9. PILE JETTING SHALL NOT BE ALLOWED
10. PILE LOGS SHALL BE RECORDED BY THE CONTRACTOR FOR ALL DRIVEN PILES, PILE DRIVING SHALL BE INSPECTED BY
AN INDEPENDENT GEOTECHNICAL ENGINEER HIRED BY THE CONTRACTOR.
11. CONCRETE PILING SHALL BE FROM AN FDOT CERTIFIED FACILITY OF PRESTRESSED CONCRETE PRODUCTS.
12. CONTRACTOR SHALL HIRE INDEPENDENT TESTING LAB TO PERFORM VIBRATION MONITORING DURING PILE INSTALLATION OF ADJACENT BRIDGE THROUGHOUT THE PILE INSTALLATION. MONITORING SHALL BE IN ACCORDANCE WITH FDOT 108.2 AND MONITORING PLAN SHALL BE SUBMITTED FOR APPROVAL BY ENGINEER AND OWNER.
13. CONTRACTOR TO INSPECT EXISTING TO REMAIN CONCRETE PILES AND SUBMIT PHOTOS TO EOR PRIOR TO START OF
CONSTRUCTION.
LUMBER & TIMBER:
1. ALL DIMENSIONAL LUMBER SHALL BE PRESSURE TREATED TO COMPLY WITH AWPA UC4B STANDARDS FOR USE IN MARINE SALT WATER SPLASH CONDITIONS AND SHALL BE SOUTHERN PINE, NO. 1. DENSE GRADE SYP OR BETTER
UNLESS OTHERWISE NOTED.
2. DECKING AND RAILS SHALL BE BLACK LOCUST 5/4" X 6" BOARDS. DECKING SHALL HAVE 18" GAPPING BETWEEN BOARDS.
3. BLACK LOCUST DECKING SHALL BE DRIED FOR EXTERIOR USE.
4. BLACK LOCUST DECKING SHALL MEET ASTM C 1028 TESTING STANDARDS FOR ADA REQUIREMENTS OF THE STATIC
COEFFICIENT OF FRICTION IN THE WET ENVIRONMENT.
5. BLACK LOCUST DECKING SHALL BE FROM THE HEARTWOOD OF THE BLACK LOCUST TREES, AVOIDING THE SAPWOOD
OF THE TREE.
6. TIMBER JOISTS SHALL HAVE VYCOR DECK PROTECTOR OR ENGINEER APPROVED EQUAL JOIST TAPE APPLIED TO TOP
FACE OF JOIST
SURVEY & GEOTECHNICAL DATA:
1. BATHYMETRIC SURVEY PROVIDED BY PALM BEACH COUNTY, DATED 6/7/21.
2. EXISTING SITE PLAN ELEVATIONS PROVIDED BY PALM BEACH COUNTY, OLD BRIDGE PARK PUBLIC USE FACILITIES
DRAWINGS, DATED 7/14/16.
3. ALL ELEVATIONS ARE IN NAVD88 DATUM UNLESS OTHERWISE NOTED.
4. GEOTECHNICAL REPORT BY TERRACON CONSULTANTS, INC. DATED 10/27/2015.
CONCRETE:
1. NO REPAIRS SHALL BE MADE DURING UNFAVORABLE WEATHER OR SEA CONDITIONS.
2. COMPONENTS NOT CONSTRUCTED ACCORDING TO THESE SPECIFICATIONS SHALL BE REMOVED AND REPLACED
PROPERLY AT THE EXPENSE OF THE CONTRACTOR.
3. THE FACES OF THE FINISHED STRUCTURES SHALL BE TRUE, STRAIGHT, AND OF UNIFORM WIDTH, FREE FROM HUMPS, SAGS, OR OTHER IRREGULARITIES EXCEPT AS SPECIFIED IN THE PLANS. THE CONTRACTOR SHALL REPLACE ANY
DEFICIENT SEGMENTS.
4. SEE SHEET 10 FOR COMPLETE CONCRETE REPAIR NOTES.
TIDAL DATA:
1. WATER LEVELS TAKEN FROM NOAA STATION ID 8722654, WEST PALM BEACH FL.
2. CONTRACTOR MAY NEED TO ADJUST HIS WORK PLAN TO ACCOUNT FOR ACTUAL WATER LEVELS AND CHANGING
WATER LEVELS. THE SITE MAY BE SUBJECT TO VARIABLE WAVE AND SURGE CONDITIONS.
HARDWARE:
1. ALL HARDWARE, BOLTS, AND OTHER MISC. STEEL COMPONENTS SHALL BE STAINLESS STEEL TYPE 316 MARINE GRADE
UNLESS OTHERWISE NOTED.
2. DOWELS OR ANCHORS EMBEDDED INTO CONCRETE SHALL BE ANCHORED WITH SIMPSON SET TWO-PART EPOXY OR ENGINEER APPROVED EQUIVALENT. ANCHOR HOLES SHALL BE DRIVEN TO MINIMUM DEPTH SHOWN ON THE PLANS, AND
SHALL BE THOROUGHLY CLEANED OUT AND DRY PRIOR TO INJECTION OF EPOXY.
3. CLEATS SHALL BE MARINE GALV. STEEL.
4. DECK SCREWS SHALL BE #10, 3” SS, 2 PER STRINGER @ 3” O.C.. SPACE EVENLY AND CONSISTENTLY WITH CHALK LINE
FOR NEAT DECKBOARD FINISH, PRE-DRILLING MAY BE REQUIRED.
SUBMITTALS:
1. REVIEW OF SUBMITTALS BY THE ENGINEER IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT AS PRESENTED BY THE CONTRACT DOCUMENTS. NO DETAILED CHECK OF QUANTITIES OR DIMENSIONS WILL BE MADE.
2. ALL SHOP DRAWINGS MUST BEAR EVIDENCE OF THE CONTRACTOR'S APPROVAL PRIOR TO SUBMITTING TO THE
ENGINEER.
3. THE FOLLOWING MINIMUM SUBMITTALS SHALL BE PREPARED BY THE CONTRACTOR AND SUBMITTED TO THE ENGINEER
FOR REVIEW AND APPROVAL PRIOR TO RELATED CONSTRUCTION ACTIVITY:
· SCHEDULE FOR COMPLETION OF WORK WITH TASKS
· DEMOLITION METHODS AND DISPOSAL PLAN
· PILING
· FENDER AND PILE ACCESSORIES
· LUMBER
· HARDWARE
· EPOXY
· DOCK ACCESSORIES
· PILE DRIVING EQUIPMENT AND METHODOLOGY
· DECKING
· CLEATS
· CONCRETE REPAIR MATERIALS
· LADDERS
· PILE LOGS
· VIBRATION MONITORING PLAN
· JOIST TAPE
· PHOTOS OF EXISTING TO REMAIN CONCRETE PILES PRIOR TO CONSTRUCTION
LAYOUT AND TESTING:
1. ALL CONSTRUCTION STAKEOUT SHALL BE PERFORMED BY AND PAID FOR BY THE CONTRACTOR UNDER THE
SUPERVISION OF A SURVEYOR REGISTERED IN THE STATE OF FLORIDA.
2. CONTRACTOR TO CONDUCT PRECONSTRUCTION AND AS-BUILT SURVEY. SURVEYS SHALL BE SIGNED AND SEALED BY A
SURVEYOR REGISTERED IN THE STATE OF FLORIDA.
UTILITIES:
1. CONTRACTOR SHALL CALL SUNSHINE 1-800-432-4770, PRIOR TO CONSTRUCTION. CONTRACTOR RESPONSIBLE FOR LOCATING ALL PRESENT UTILITIES PRIOR TO CONSTRUCTION. NO PILE DRIVING SHALL TAKE PLACE WITHIN THE
DESIGNATED CONSTRUCTION AREA UNTIL UTILITY LOCATIONS HAVE BEEN FIELD VERIFIED.
2. PRIOR TO ANY SCHEDULED INTERRUPTION OF UTILITY SERVICE, THE CONTRACTOR WILL COORDINATE SUCH INTERRUPTION WITH THE UTILITY PROVIDER AND WILL PROVIDE A MINIMUM 24-HOUR NOTICE TO THE AFFECTED PARTIES. THE CONTRACTOR WILL NOTIFY THE ELECTRIC UTILITY A MINIMUM OF TWO WEEKS PRIOR TO CONSTRUCTION
IN THE VICINITY OF THEIR FACILITIES.
ABBREVIATIONS
ACI AMERICAN CONCRETE INSTITUTE
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
CONT CONTINUOUS
CONT'D CONTINUED
DIA DIAMETER
FDEP FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION
FDOT FLORIDA DEPARTMENT OF TRANSPORTATION
GALV GALVANIZED
KSI KIPS PER SQUARE INCH
MHW MEAN HIGH WATER
MIN MINIMUM
MLW MEAN LOW WATER
NAVD NORTH AMERICAN VERTICAL DATUM
NGVD NATIONAL GEODETIC VERTICAL DATUM
O.C. ON CENTER
PERA PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS
PSI POUNDS PER SQUARE INCH
S.S. STAINLESS STEEL
T US TON
TYP TYPICAL
USACE UNITED STATES ARMY CORPS OF ENGINEERS
W/C WATER/CEMENT RATIO
SECTION CUT
DETAIL SYMBOL
SYMBOLS LEGEND
DIRECTION OF VIEW
FOR SECTION CUT
SHEET WHERE SECTION IS SHOWN
SECTION LETTER
SHEET WHERE
DETAIL IS SHOWN
DETAIL NUMBER
AutoCAD SHX Text
(561) 233-2400
AutoCAD SHX Text
ENVIRONMENTAL RESOURCES MANAGEMENT
AutoCAD SHX Text
PALM BEACH COUNTY
AutoCAD SHX Text
DEPARTMENT OF
AutoCAD SHX Text
WEST PALM BEACH, FLORIDA 33411
2300 NORTH JOG ROAD, 4th FLOOR
BASIS OF BEARINGS
N86°00'26"W (ASSUMED)
ALONG CENTERLINE S.R. 802
N04°41'02"E, 43.95'
N76°48'22"E, 29.54'
N44°52'06"E, 20.65'
N34°08'59"W, 29.97'
R/W LINE
N75°36'36"W, 21.18'
N86°00'26"W 885.85'
S03°59'34"W, 25.00'
S85°59'06"E 470.25'
P4
P1P2
P5
P3
PROPERTY LINE
BRIDGE GUARDRAIL
5.72
5.0 3.0
4.0
5.57 5.54
5.0
5.84
5.34
5.45
4.95
5.29
4.87
4.49
5.32
5.05
4.77
5.44
5.54
5.10
4.13
5.0
5.0
5.12
5.12
5.60
5.50
5.18
5.18
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.72 5.82
5.70
5.79
5.67
3.0
5.0
5.18
4.5
PARKING LOT
DESIGNATED
CONSTRUCTION
STAGING AREA
EXISTING RIPRAP
FLOATING DECK & GANGWAY SHOWN
IN AERIAL HAVE BEEN REMOVED
(2) EXISTING 14" CONC. PILES
TO REMAIN (TYP.)
EXISTING
BULKHEAD
(3) EXISTING PILES
TO BE REMOVED (TYP.)
AT&T CABLES
(ESTIMATED LOCATION)
AS
N
O
TE
D
D
AT
E:
SC
AL
E:
D R
AW
N
C H
EC
KE
D
AP
PR
O
VE
D
PR
OJ
EC
T:
SHEET:
J:
\P ro je ct s\
PB
C O ld B rid ge
P ar k\ D ra w in gs
\W or ki ng
\(2
6-
-0 4)
P
PB
C
O ld
B rid ge P ar k.
dw g
D
AT
E:
/4 /2
IN
TR
AC
O
AS
TA
L
PO
IN
T, S U
IT
E
JU
PI
TE
R
, F
LO
R
ID
A
PH
O
N E:
W W
W .C
U M
M
IN
SC
ED
ER
BE
R G
.C O
M C
O A
C U
M M
IN
S
C
E D
E R
B E
R G
C oa st al
M ar in e E ng in ee ri ng
PU
BL
IC
U
SE
F
AC
IL
IT
IE
S
3/ 4/
JD
R
O
LD
B R
ID
G
E
PA
R K
JP
C
M G
SCALE: 1"=15'
NOTES:
1. POINTS P1 TO P5 DEFINE CENTER OF DOCK PILES.
BASED ON ORIGINAL CONSTRUCTION PLANS.
CONTRACTOR TO FIELD VERIFY.
2. AERIAL FROM MS & MAXAR DATED 2025.
EX
IS
T.
C
O
ND
IT
IO
NS
D
EM
O
PL
AN
LEGEND:
PILES TO BE REMOVED
PILES TO REMAIN
DEMOLITION QUANTITIES
ITEM QUANTITY UNIT
14" SQ. CONC. PILES 3 EA
SCALE 1"=15' (22X34 SHEET)
1"=30' (11X17 SHEET)
AutoCAD SHX Text C
AutoCAD SHX Text L
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text -6.00
AutoCAD SHX Text -5.00
AutoCAD SHX Text -4.00
AutoCAD SHX Text -3.00
AutoCAD SHX Text -7.00
AutoCAD SHX Text 30'
AutoCAD SHX Text
(561) 233-2400
AutoCAD SHX Text
ENVIRONMENTAL RESOURCES MANAGEMENT
AutoCAD SHX Text
PALM BEACH COUNTY
AutoCAD SHX Text
DEPARTMENT OF
AutoCAD SHX Text
WEST PALM BEACH, FLORIDA 33411
O
TE
D
D
AT
E:
SC
AL
E:
D R
AW
N
C H
EC
KE
D
AP
PR
O
VE
D
PR
OJ
EC
T:
SHEET:
J:
\P ro je ct s\
PB
C O ld B rid ge
P ar k\ D ra w in gs
\W or ki ng
\(2
6-
-0 4)
P
PB
C
O ld
B rid ge P ar k.
dw g
D
AT
E:
/4 /2
IN
TR
AC
O
AS
TA
L
PO
IN
T, S U
IT
E
JU
PI
TE
R
, F
LO
R
ID
A
PH
O
N E:
W W
W .C
U M
M
IN
SC
ED
ER
BE
R G
.C O
M C
O A
C U
M M
IN
S
C
E D
E R
B E
R G
C oa st al
M ar in e E ng in ee ri ng
PU
BL
IC
U
SE
F
AC
IL
IT
IE
S
3/ 4/
JD
R
O
LD
B R
ID
G
E
PA
R K
G
EO
TE
C
H . B
O R
IN
G
S
JP
C
M G
NOTE:
GEOTECHNICAL STUDY BY TERRACON DATED 9-25-15. SHOWN FOR INFORMATIONAL PURPOSES ONLY.
CONTRACTORS BIDDING THIS PROJECT SHOULD BE AWARE OF THE HARDNESS OF THE ROCK FORMATION AND THE IMPLICATIONS OF HARD ROCK IN THE SELECTION OF CONSTRUCTION EQUIPMENT. BASED ON THE SPT N-VALUES, THE COQUINA FORMATION IS DESCRIBED AS VERY WELL CEMENTED. PILE DRIVING IN VERY WELL CEMENTED COQUINA FORMATION MAY BE DIFFICULT. CONTRACTOR SHALL BE PREPARED TO PREPUNCH
OR PREDRILL HOLES AS NECESSARY TO ACHIEVE EMBEDMENT
AutoCAD SHX Text
(561) 233-2400
AutoCAD SHX Text
ENVIRONMENTAL RESOURCES MANAGEMENT
AutoCAD SHX Text
PALM BEACH COUNTY
AutoCAD SHX Text
DEPARTMENT OF
AutoCAD SHX Text
WEST PALM BEACH, FLORIDA 33411
LEGEND:
PROPOSED PILES
EXISTING PILES TO REMAIN
PROPOSED SITE PLAN
SCALE 1"=10' (22X34 SHEET)
1"=20' (11X17 SHEET)
AS
N
O
TE
D
D
AT
E:
SC
AL
E:
D R
AW
N
C H
EC
KE
D
AP
PR
O
VE
D
PR
OJ
EC
T:
SHEET:
J:
\P ro je ct s\
PB
C O ld B rid ge
P ar k\ D ra w in gs
\W or ki ng
\(2
6-
-0 4)
P
PB
C
O ld
B rid ge P ar k.
dw g
D
AT
E:
/4 /2
IN
TR
AC
O
AS
TA
L
PO
IN
T, S U
IT
E
JU
PI
TE
R
, F
LO
R
ID
A
PH
O
N E:
W W
W .C
U M
M
IN
SC
ED
ER
BE
R G
.C O
M C
O A
C U
M M
IN
S
C
E D
E R
B E
R G
C oa st al
M ar in e E ng in ee ri ng
PU
BL
IC
U
SE
F
AC
IL
IT
IE
S
3/ 4/
JD
R
O
LD
B R
ID
G
E
PA
R K
PR
O
PO
SE
D S
IT
E
PL
AN
JP
C
M G
(2) EXIST. PILES TO REMAIN
8'
PROPOSED FIXED DOCK.
BLACK LOCUST DECKING ON
WOOD FRAMING AND
CONCRETE PILES.
(24) PROPOSED
PILES, TYP
REPAIR 8"LX3"WX3"D
CONCRETE SPALL ON NORTH
EDGE OF CAP AT DOCK/CAP
CONNECTION TO WALL.
SEE SHEET 10 FOR DETAILS
PILE QUANTITY TABLE
ITEM SIZE MATERIAL QUANTITY
PILES TO REMAIN 14" S.Q. CONCRETE 2
PROPOSED PILES 14" S.Q. CONCRETE 24
LAKE WORTH LAGOON
EXIST. RIPRAP
EXIST. BULKHEAD
EXIST. LANDING
PLATFORM
OVERWATER FOOTPRINT AREA
ITEM SQUARE FEET
FIXED DOCK 801
6'
105'
25'
PARKING LOT DESIGNATED
CONSTRUCTION STAGING AREA,
SEE SHEET 3 FOR FULL EXTENTS
AT&T CABLES
(ESTIMATED LOCATION)
PROPOSED
LADDERS, TYP.
AutoCAD SHX Text 20'
AutoCAD SHX Text -6.00
AutoCAD SHX Text -5.00
AutoCAD SHX Text -4.00
AutoCAD SHX Text -3.00
AutoCAD SHX Text -7.00
AutoCAD SHX Text -7.00
AutoCAD SHX Text
(561) 233-2400
AutoCAD SHX Text
ENVIRONMENTAL RESOURCES MANAGEMENT
AutoCAD SHX Text
PALM BEACH COUNTY
AutoCAD SHX Text
DEPARTMENT OF
AutoCAD SHX Text
WEST PALM BEACH, FLORIDA 33411
8'-0"
105'-0"
6'-0"
8'-3" 8'-3" 8'-3" 8'-3" 8'-4" 8'-4" 8'-4" 7'-6" 7'-6" 7'-6" 7'-6" 8'-6" 8'-6"
105'-0"
8'-3" 8'-3" 8'-3" 8'-3" 8'-4" 8'-4" 8'-4" 7'-6" 7'-6" 7'-6" 7'-6" 8'-6" 8'-6"
-4 .2
-3 .7
-3 .5
-3 .1
-2 .1
EL. +5.00' NAVD
EL. +3.8' NAVD
TIP OF PILE
EL=-13.0' NAVD
MIN. 5' EMBEDMENT
INTO ROCK LAYER.
-5 .6
-5 .2
-5 .4
-5 .5
-5 .0
-4 .8
-4 .6
MHW +0.10'
MLW -2.36'
TOP OF PILE
EL +8.0' NAVD
EL. +3.60' NAVD
EL -3.3' NAVD
RAMP AT CONSISTENT SLOPE. MAX SLOPE 1V:12H
AS
N
O
TE
D
D
AT
E:
SC
AL
E:
D R
AW
N
C H
EC
KE
D
AP
PR
O
VE
D
PR
OJ
EC
T:
SHEET:
J:
\P ro je ct s\
PB
C O ld B rid ge
P ar k\ D ra w in gs
\W or ki ng
\(2
6-
-0 4)
P
PB
C
O ld
B rid ge P ar k.
dw g
D
AT
E:
/4 /2
IN
TR
AC
O
AS
TA
L
PO
IN
T, S U
IT
E
JU
PI
TE
R
, F
LO
R
ID
A
PH
O
N E:
W W
W .C
U M
M
IN
SC
ED
ER
BE
R G
.C O
M C
O A
C U
M M
IN
S
C
E D
E R
B E
R G
C oa st al
M ar in e E ng in ee ri ng
PU
BL
IC
U
SE
F
AC
IL
IT
IE
S
/2
3/
21JD
R O
LD
B
R
ID
G E
PA
R
K
D O
C K
FR
AM
IN
G
S
EC
JP
C
M G
TYPICAL FRAMING PLAN
5/4X6 BLACK LOCUST
DECKING, TYP.
3x8 WOOD JOIST @ 18" O/C MAX, TYP.
INSTALL VYCOR DECK PROTECTOR
OR EOR APPROVED EQUAL JOIST
TAPE TO TOP FACE OF JOIST, TYP.
4X12 WOOD
BEAM, TYP.
3x8 WOOD BLOCKING @
CLEAT, TYP.
SAFETY LADDER1
DOCK SECTION
EXIST. PILE
EXIST. PILE
EXIST. PILE
(TIP EL.
UNKNOWN)
EXIST. PILE
(TIP EL. UNKNOWN)4x12 WOOD BEAM
12" GALV.
CLEAT, TYP.
14" SQ CONC.
PILES, TYP.
BLACK PVC
CONICAL CAP, TYP.
3X8 WOOD BLOCKING AT MIDPSPAN.
FASTEN WITH (2) 10D NAILS AT EA. END IN A
STAGGERED PATTERN. NAILS TO BE MIN
1.5'' FROM TOP AND BOTTOM EDGES OF
BLOCKING AND SPACED MIN 2'' APART.
TOE-NAIL THE LAST BLOCKING ON EACH
END TYP.
BLACK LOCUST
DECKING, TYP.
VERTICAL RUBBER
FENDER, TYP.
EXISTING
RIPRAP
EXISTING
BULKHEAD
MUDLINE ELEVATIONS FROM PBC
OLD BRIDGE PARK PUBLIC USE
FACILITIES DRAWINGS DATED
7/14/16.
SAFETY
LADDER
JOISTS CONNECTED
BETWEEN BEAM
LOCATIONS
EXISTING PILE TO BE CUT TO +8.0' NAVD
AS NEEDED TO MATCH NEW PILES
EXISTING PILE TO BE CUT
TO 2.9' NAVD TO MATCH NEW
BELOW DECK PILES
EXISTING
BULKHEAD BEAM TO PILE
CONNECTION, TYP.
EXISTING CONC.
BULKHEAD CAP
JOISTS AT RAMP TO DECK TRANSITION SHALL HAVE MIN.
3" LAP AND SHALL BE FASTENED TOGETHER WITH (3) 10D
NAILS ON AT EA END. NAILS TO BE MIN. 1.5" FROM TOP
AND BOTTOM OF JOIST AND SPACED MIN 2" APART.
4X6 WOOD GUARD POST
CENTERED BETWEEN
CONCRETE PILES, TYP.
14" SQ CONC.
PILE, TYP.
EXIST. PILE
EDGE JOIST
SCALE 1"=4' (22X34 SHEET)
1"=8' (11X17 SHEET)
SCALE 1"=4' (22X34 SHEET)
1"=8' (11X17 SHEET)
EDGE JOIST AT RAILING POST SHALL AVOID POST BOLTING
TO BUTT-BUTT CONNECTION. STAGGER JOIST CONNECTION
AS NEEDED TO AVOID CONFLICT WITH BOLT AND STRAP.
AutoCAD SHX Text
(561) 233-2400
AutoCAD SHX Text
ENVIRONMENTAL RESOURCES MANAGEMENT
AutoCAD SHX Text
PALM BEACH COUNTY
AutoCAD SHX Text
DEPARTMENT OF
AutoCAD SHX Text
WEST PALM BEACH, FLORIDA 33411
8'-0"
MHW +0.10'
MLW -2.36'
5/4 x 6 BLACK LOCUST
DECKING, TYP
14" CONC. PILE, TYP.
EL +6.5' NAVD
TOP OF FENDER
4x12 WOOD BEAM, TYP
EL -3.3' NAVD
BOTTOM OF FENDER
3X8 WOOD
JOISTS SPACED
@18" O.C., TYP.
T/DECK EL +3.6' NAVD
VERT. FENDER, TYP.
SIMPSON LTS12 SS
STRAP, TYP.
EA. JOIST
STAGGERED.
EL +8.0' NAVD
TOP OF PILE
6'-10"
BLACK PVC
CONICAL CAP, TYP.
PILE TIP
EL. -13.0' NAVD
6'-0"
MHW +0.10'
MLW -2.36'
5/4 x 6 BLACK
LOCUST
DECKING, TYP
14" CONC. PILE, TYP.
4x12 WOOD BEAM, TYP
3X8 WOOD
JOISTS SPACED
@18" O.C., TYP.
SIMPSON LTS12
SS STRAP, TYP.
EA. JOIST
STAGGERED.
RAILING
PILE TIP
EL. -13.0' NAVD
5'-8"
EL VARIES
T/PILE EL VARIES
EL VARIES
8'-0"
MHW +0.10'
MLW -2.36'
5/4 x 6 BLACK LOCUST
DECKING, TYP
14" CONC. PILE, TYP.
4x12 WOOD BEAM, TYP
3X8 WOOD JOISTS
SPACED @18" O.C., TYP.
T/DECK EL +3.6' NAVD
SIMPSON LTS12 SS STRAP, TYP.
EA. JOIST STAGGERED.
6'-10"
PILE TIP
EL. -13.0' NAVD
T/PILE EL +2.9' NAVD
T/RAILING EL +7.27' NAVD
AS
N
O
TE
D
D
AT
E:
SC
AL
E:
D R
AW
N
C H
EC
KE
D
AP
PR
O
VE
D
PR
OJ
EC
T:
SHEET:
J:
\P ro je ct s\
PB
C O ld B rid ge
P ar k\ D ra w in gs
\W or ki ng
\(2
6-
-0 4)
P
PB
C
O ld
B rid ge P ar k.
dw g
D
AT
E:
/4 /2
IN
TR
AC
O
AS
TA
L
PO
IN
T, S U
IT
E
JU
PI
TE
R
, F
LO
R
ID
A
PH
O
N E:
W W
W .C
U M
M
IN
SC
ED
ER
BE
R G
.C O
M C
O A
C U
M M
IN
S
C
E D
E R
B E
R G
C oa st al
M ar in e E ng in ee ri ng
PU
BL
IC
U
SE
F
AC
IL
IT
IE
S
3/ 4/
JD
R
O
LD
B R
ID
G
E
PA
D
C
K D
ET
AI
LS
JP
C
M G
DOCK SECTION AT MOORING LOCATIONS
14" PRESTRESSED PILE DETAIL
N.T.S
1. Fc' = 6,000 PSI (MIN)
2. (8) 1/2" DIA, GRADE 270 LRS
3. MIN. 3" COVER ON ALL REINF.
4. ALL PILINGS TO FDOT CONCR. CLASS V SPEC.
5. CONTRACTOR TO MAINTAIN PILE LOGS.
6. PILES SHALL BE FROM A FDOT CERTIFIED FACILITY
OF PRESTRESSED CONCRETE PRODUCTS.
14"x14" PILE SPECIFICATION:
3"
1"
5 TURNS @ 1" PITCH
16 TURNS @ 3" PITCH 6" PITCH
W3.4 SPIRAL TIES
16 TURNS @ 3" PITCH
5 TURNS @ 1" PITCH
1"SPIRAL TIE
SPACING
14"
3" COVER (TYP.)
W3.4 SPIRAL TIES
A
A
SECTION A-A
4" X 3" CHAMFER
(TYP.)
3"
RAMP SECTION
SCALE 1"=2' (22X34 SHEET)
1"=4' (11X17 SHEET)
7SCALE 1"=2' (22X34 SHEET)
1"=4' (11X17 SHEET)
DOCK SECTION WITH RAIL3
7 SCALE 1"=2' (22X34 SHEET)
1"=4' (11X17 SHEET)
AutoCAD SHX Text
(561) 233-2400
AutoCAD SHX Text
ENVIRONMENTAL RESOURCES MANAGEMENT
AutoCAD SHX Text
PALM BEACH COUNTY
AutoCAD SHX Text
DEPARTMENT OF
AutoCAD SHX Text
WEST PALM BEACH, FLORIDA 33411
3X8 WOOD JOIST
MHW +0.10'
7/8" DIA EPOXY ANCHOR
SPACED 12'' MAX O.C.
WITH 9" CONC. EMBED
MLW -2.36'
5/4 X 6 BLACK LOCUST
DECKING
3X12 WOOD LEDGER
30"
9"
RAILING NOT SHOWN
FOR CLARITY
6'-0"
7/8'' DIA EPOXY
ANCHOR SPACED 12''
MAX O.C. WITH 9''
CONCR. EMBED
3X12 WOOD LEDGER
12"6"
AS
N
O
TE
D
D
AT
E:
SC
AL
E:
D R
AW
N
C H
EC
KE
D
AP
PR
O
VE
D
PR
OJ
EC
T:
SHEET:
J:
\P ro je ct s\
PB
C O ld B rid ge
P ar k\ D ra w in gs
\W or ki ng
\(2
6-
-0 4)
P
PB
C
O ld
B rid ge P ar k.
dw g
D
AT
E:
/4 /2
IN
TR
AC
O
AS
TA
L
PO
IN
T, S U
IT
E
JU
PI
TE
R
, F
LO
R
ID
A
PH
O
N E:
W W
W .C
U M
M
IN
SC
ED
ER
BE
R G
.C O
M C
O A
C U
M M
IN
S
C
E D
E R
B E
R G
C oa st al
M ar in e E ng in ee ri ng
PU
BL
IC
U
SE
F
AC
IL
IT
IE
S
3/ 4/
JD
R
O
LD
B R
ID
G
E
PA
D
C
K D
ET
AI
LS
JP
C
M G
JOIST, TYP.
3X8 WD.
BLOCKING @
FASTENERS
RETRACTABLE MARINE
GRADE ALUMINUM DOCK
LADDER W/ 300 LB
CAPACITY
TYPICAL DOCK LADDER
1' -0
M
IN
MHW +0.10'
MLW -2.36'
N.T.S.
(4) 12"Ø MOUNTING BOLTS
OR EQUAL PER LADDER
MANUFACTURER TO
ACHIEVE CAPACITY
TYPICAL DOCK CLEAT DETAIL
SCALE: 1"= 1'
ELEVATION SECTION
TYPICAL 12"
GALV. DOCK
CLEAT
JOIST, TYP.
DECKING,
TYP.
THRU BOLT
(TYP.)
3X8X2'-0" WOOD
BLOCKING @ CLEAT 3X8 EDGE JOIST, TYP.3X8
MID-SPAN
BLOCKING
(2) 5 8Ø THRU
BOLTS @ 15" O.C.
CTD. IN JOISTS
4" RUBBER FENDER W/
2"Ø EPOXY ANCHOR
SPACING PER MFR.
14" SQ. CONCRETE PILE DECKING, TYP.
FENDER DETAIL 6
8N.T.S.
FENDER DETAIL 7
8N.T.S.
B D
G H H
ACØE
A B ØC D ØE ØF G H FLAT
BAR
BOLT
SIZE WEIGHT
100 100 50 45 30 15 90-130 200-300 40x50 M126 8.5
FENDER
SIZE
E R
150 3.2 115
EXTRUSIONS
dd-SERIES
(UNITS: mm, kg/m)
(UNITS: Nm, kN)
EPOXY ANCHORS W/ 8"
EMBED. FOR CONC.
JOIST CONNECTION DETAIL
SCALE: 22x34 - 1" = 1'
11x17 - 1" = 2'
SIMPSON MSTA 12 SS OR
EQUAL W/10DX21
2" NAILS
BEAM, TYP.
LTS 12 SS STRAP
STAGGERED
JOIST, TYP.
DECKING, TYP.
2"
DECKING &
JOIST NOT
SHOWN
(2) 1"Ø S.S. EPOXIED
THRU BOLTS W/NUTS &
WASHERS AT 3.5' O.C.
STAGGERED IN
PILE/BEAM 4" M
IN
3.
5" M
IN
BEAM, TYP
CONCRETE
PILE, TYP.
BEAM TO PILE CONNECTION DETAIL 4
8N.T.S.
RAMP CONNECTION TO CONCRETE CAP DETAIL
N.T.S.
EXISTING BULKHEAD
TO REMAIN
LEDGER DETAIL
N.T.S.
ELEVATION
DECKING, TYP
EL +5.0' NAVD
AutoCAD SHX Text
(561) 233-2400
AutoCAD SHX Text
ENVIRONMENTAL RESOURCES MANAGEMENT
AutoCAD SHX Text
PALM BEACH COUNTY
AutoCAD SHX Text
DEPARTMENT OF
AutoCAD SHX Text
WEST PALM BEACH, FLORIDA 33411
3X8 WOOD EDGE
JOIST, TYP.
14" CONC. PILE, TYP.
3' -8
5/4X6 BLACK LOCUST TOP
RAIL CONNECT TO POST WITH
(2) 10D SS THREADED NAILS.
PRE-DRILL PILOT HOLES TO
PREVENT SPLITTING.
2X4 WOOD RAIL. NAILED WITH
(2) 10D S.S. THREADED NAILS
AT TOP AND BOTTOM TO
GUARD POSTS, TYP.
4X6 WOOD GUARD POST
CENTERED BETWEEN
CONCRETE PILES, TYP.
4" M
AX.
8'-6" 8'-6"
T/PILE EL +3.8' NAVD
T/CAP
EL +5.0' NAVD
4'-3"4'-3"4'-3"4'-3"
OPEN
OPEN
OPEN
OPEN
OPEN
3.5"
3.5"
3.5"
3.5"
3.5"
3.5"
T/PILE EL +3.4' NAVD
7'-6"
OPEN
T/PILE EL +2.9' NAVD
T/DECK EL +3.6' NAVD
T/RAILING EL +7.20' NAVD
3'-9"3'-9"
(2) 1/2" DIA. SS THRU-BOLTS
W/ NUTS & WASHERS LOCATED THRU
CENTER POST MIN. 2.5" OF EDGE
DISTANCE AND BOLTS SPACED MIN.
2.25" O.C.,TYP. MAINTAIN 2.5" OF
END DISTANCE. STAGGER JOIST BUTT
TO BUTT CONNECTION AS NEEDED.
EDGE JOIST, TYP.
DTT2SS SIMPSON
TIE HOLD
DOWN ANCHOR
3X8 WOOD
BLOCKING
14" CONC.
PILE, TYP.
3.
5"
3' -8
2"
5/4X6 BLACK LOCUST
TOP RAIL SLOPED AT 15
DEGREES
DECKING, TYP.
2X4 WOOD
RAIL
4X6 TIMBER
GUARD POST
TOP-INSIDE EDGE OF
TOP RAIL EASED ROUND
CHAMFER TOP EDGE OF
SIDE RAIL TO SUPPORT
TOP RAIL AS NEEDED
3' -0
ADA COMPLAINT HANDRAIL
OUTSIDE DIAMETER SHALL
NOT BE LESS THAN 1.25" AND
NOT GREATER THAN
2".PROJECTION INTO
ACCESSIBLE ROUTE SHALL
NOT EXCEED 4.5".
AS
N
O
TE
D
D
AT
E:
SC
AL
E:
D R
AW
N
C H
EC
KE
D
AP
PR
O
VE
D
PR
OJ
EC
T:
SHEET:
J:
\P ro je ct s\
PB
C O ld B rid ge
P ar k\ D ra w in gs
\W or ki ng
\(2
6-
-0 4)
P
PB
C
O ld
B rid ge P ar k.
dw g
D
AT
E:
/4 /2
IN
TR
AC
O
AS
TA
L
PO
IN
T, S U
IT
E
JU
PI
TE
R
, F
LO
R
ID
A
PH
O
N E:
W W
W .C
U M
M
IN
SC
ED
ER
BE
R G
.C O
M C
O A
C U
M M
IN
S
C
E D
E R
B E
R G
C oa st al
M ar in e E ng in ee ri ng
PU
BL
IC
U
SE
F
AC
IL
IT
IE
S
3/ 4/
JD
R
O
LD
B R
ID
G
E
PA
AI
LI
N G
D
ET
AI
LS
JP
C
M G
TYPICAL RAILING ELEVATION @ RAMP SECTION
SCALE 1"=1'
SECTION
SCALE 1"=1'
JOIST, TYP.
3X8 WOOD
BLOCKING
(2) 12" Ø S.S.
THRU BOLT, TYP.
4X6 WOOD
GUARD POST, TYP.
EDGE JOIST, TYP.
1/2" DIA SIMPSON
DTT2SS STRAPS WITH
(8) 1.5" SDS SCREWS
TYPICAL EDGE JOIST CONNECTION
FOR POST CONNECTION
SCALE 1"=1/2'
RAILING DETAILS
AutoCAD SHX Text
(561) 233-2400
AutoCAD SHX Text
ENVIRONMENTAL RESOURCES MANAGEMENT
AutoCAD SHX Text
PALM BEACH COUNTY
AutoCAD SHX Text
DEPARTMENT OF
AutoCAD SHX Text
WEST PALM BEACH, FLORIDA 33411
O
TE
D
D
AT
E:
SC
AL
E:
D R
AW
N
C H
EC
KE
D
AP
PR
O
VE
D
PR
OJ
EC
T:
SHEET:
J:
\P ro je ct s\
PB
C O ld B rid ge
P ar k\ D ra w in gs
\W or ki ng
\(2
6-
-0 4)
P
PB
C
O ld
B rid ge P ar k.
dw g
D
AT
E:
/4 /2
IN
TR
AC
O
AS
TA
L
PO
IN
T, S U
IT
E
JU
PI
TE
R
, F
LO
R
ID
A
PH
O
N E:
W W
W .C
U M
M
IN
SC
ED
ER
BE
R G
.C O
M C
O A
C U
M M
IN
S
C
E D
E R
B E
R G
C oa st al
M ar in e E ng in ee ri ng
PU
BL
IC
U
SE
F
AC
IL
IT
IE
S
3/ 4/
JD
R
O
LD
B R
ID
G
E
PA
R K
C O
N C
. R
EP
AI
R
D
ET
JP
C
M G
CLEAN & FILL
CRACKS 1/32" THICK
OR WIDER WITH
REPAIR EPOXY
AREA OF SPALLED
CONCRETE
LIMITS OF UNSOUND CONCRETE.
REMOVE & REPAIR WITH
OVERHEAD PATCH. (SEE NOTES
ON THIS SHEET)
CLEAN & TREAT
EXPOSED
REINFORCEMENT
STEEL. (SEE NOTES
ON THIS SHEET)
LIMITS OF UNSOUND
CONCRETE PRE-SPALL.
REMOVE & REPAIR WITH
OVERHEAD PATCH. (SEE
NOTES ON THIS SHEET)
EXISTING
REINFORCED
CONCRETE SLAB
CLEAN & FILL EXPOSED
CORRODING METAL
HARDWARE (TYP.)
CONCRETE SPALL REPAIR NOTES
1. REPAIR AREAS INDICATED ON SHEET 5, AND AS DIRECTED BY
ENGINEER.
2. CONTRACTOR TO NOTIFY ENGINEER OF ADDITIONAL
DAMAGE AREAS.
3. REMOVE ALL UNSOUND CONCRETE AROUND SPALL AREA BY
CHIPPING WITH PICKS OR LIGHTWEIGHT PNEUMATIC IMPACT
TOOLS TO EXPOSE SOUND CONCRETE FREE OF LOOSE AND
UNSOUND MATERIALS. CARE SHALL BE TAKEN TO AVOID
DAMAGE TO SOUND CONCRETE BEYOND THE LIMITS OF THE
DEMOLITION AND TO AVOID DISLODGING OR DAMAGING
EXPOSED, EXISTING REINFORCING STEEL.
4. SAW CUT EDGES OF REPAIR AREA TO A DEPTH OF AT LEAST
1/2" TO PROVIDE SQUARE EDGE.
5. CLEAN ALL EXPOSED SURFACES, INCLUDING THE EXPOSED
SURFACES OF THE REINFORCEMENT STEEL BY POWER WIRE
BRUSH. SURFACES SHALL BE FREE OF ANY BOND INHIBITING
OR OTHER DELETERIOUS MATERIALS. IF REINFORCING HAS
LOST MORE THAN 25% SECTION, SPLICE NEW
REINFORCEMENT TO MATCH ORIGINAL. ALL EXPOSED
REINFORCEMENT STEEL SHALL BE TREATED WITH
APPROVED CORROSIVE INHIBITOR.
6. APPLY THORTEX EPOXY MORTAR (OR EQUIVALENT) IN
ACCORDANCE WITH MANUFACTURER INSTRUCTIONS.
CONTRACTOR TO SUBMIT SPECIFICATIONS TO ENGINEER
FOR APPROVAL.
7. CURE REPAIR MATERIAL IN ACCORDANCE WITH
MANUFACTURER INSTRUCTIONS.
CONCRETE REPAIR PRODUCT SCHEDULE
APPLICATION
DESCRIPTION
CONCRETE
REPAIR PRODUCT MANUFACTURER REMARKS
BONDING
ARMATEC 110 SIKA ONLY FOR OVERHEAD APPLICATIONS. USE SCRUB COAT FOR
VERTICAL AND HORIZONTAL APPLICATIONS (OPNE AND UNCLOG
PORE STRUCTURE)PLANIBOND MAPEI
CEMENTITIOUS
ANTI-CORROSION
INHIBITING PRIMER
ARMATEC 110 SIKA
APPLY TO ALL EXPOSED SURFACES OF STEEL REINFORCEMENT
AND OTHER EMBEDDED STEEL
PLANIBOND MAPEI
HORIZONTAL REPAIRS
ZICATOP 122 PLUS SIKA CORP TROWEL APPLIED IN LIFTS. LIFT THICKNESS = 1/8" MIN. AND 1"
MAX. (NEAT) OR 4" MAX. (EXTENDED - SEE MFR DATA SHEET)
MAPECEM 202 MAPEI
VERTICAL REPAIRS
SIKATOP 123 SIKA CORP
TROWEL APPLIED IN LIFTS. LIFT THICKNESS = 1/8" MIN. AND
1-1/2" MAX. DO NOT EXCEED 8" TOTAL THICKNESS.SIKAQUICK VOH SIKA CORP
PLANITOP XS MAPEI
FORM-AND-CAST
REPAIRS
(FULL-DEPTH)
SIKACRETE 211 SCC
PLUS SIKA CORP UP TO 8" THICK APPLICATIONS. FOR APPLICATIONS
GREATER THAN 8" THICK, NOTIFY ENGINEER.PLANITOP 11 SCC MAPEI
EPOXY CRACK
INJECTION
SIKADUR 31, HI-MOD
GEL & SIKADUR 32 SIKA CORP
SEAL PORTS AND CRACKS W/ SIKADUR 31, HI-MOD GEL AND LET
CURE, THEN INJECT SIKADUR 52 W/ STEADY PRESSURE
PLANIBOND AE &
EPOJET LV MAPEI SEAL PORTS AND CRACKS W/ PLANIBOND AE AND LET CURE,
THEN INJECT EPOJET LV W/ STEADY PRESSURE
NOTES:
1. COORDINATE AND SCHEDULE A PRE-CONSTRUCTION MEETING W/ GENERAL CONTRACTOR, CONCRETE REPAIR
CONTRACTOR, PRODUCT MANUFACTURER REPRESENTATIVE, SPECIAL INSPECTOR AND ENGINEER PRIOR TO
COMMENCEMENT OF THIS WORK.
2. SUBMIT PRODUCT DATA SHEETS FOR PRODUCTS TO BE USED TO ENGINEER.
3. SUBSTITUTIONS WILL BE CONSIDERED. PROPOSED SUBSTITUTIONS SHALL BE REVIEWED AND APPROVED BY ENGINEER
PRIOR TO USE. USE PRODUCTS IN STRICT ACCORDANCE W/ MANUFACTURER'S WRITTEN RECOMMENDATIONS.
LIMITS OF UNSOUND CONCRETE PRE-SPALL.
REMOVE & REPAIR WITH OVERHEAD PATCH.
(SEE NOTES ON THIS SHEET)
AREA OF SPALLED
CONCRETE
CLEAN & TREAT EXPOSED
REINFORCEMENT STEEL.
(SEE NOTES ON THIS SHEET)
EXIST. CONC. CAP
TO REMAIN
LIMITS OF UNSOUND CONCRETE.
REMOVE & REPAIR WITH OVERHEAD PATCH.
(SEE NOTES ON THIS SHEET)
CONCRETE CAP REPAIR DETAIL (TYP.)
N.T.S.
CONCRETE CRACK REPAIR NOTES
1. REPAIR CRACKS GREATER THAN 1/32" IN AREAS INDICATED
ON SHEET 5.
2. CONCRETE SURROUNDING THE CRACKS SHALL BE TESTED
FOR SOUNDNESS BY HAND USING A LIGHT MANUAL HAMMER.
IN THE EVENT THAT THE CONCRETE SPALLS, PROPER SPALL
REPAIRS SHALL BE CONDUCTED.
3. CRACKS SHALL BE CLEANED TO ENSURE THAT CRACKS ARE
SOUND, CLEAN, DRY AND FREE OF DELETERIOUS
MATERIALS.
4. INJECT REPAIR EPOXY INTO CRACKS IN ACCORDANCE WITH
CONCRETE CAP MANUFACTURER'S INSTRUCTIONS
AutoCAD SHX Text
(561) 233-2400
AutoCAD SHX Text
ENVIRONMENTAL RESOURCES MANAGEMENT
AutoCAD SHX Text
PALM BEACH COUNTY
AutoCAD SHX Text
DEPARTMENT OF
AutoCAD SHX Text
WEST PALM BEACH, FLORIDA 33411
| 2026-03-05T08:31:48-0500 | |
| Jordon Cheifet |
File details come from the government source that posted it. Updated .