Attachment A - Capability Statement Criteria.pdf
PDF 79 KB Posted
- Attached to
- Eastern Regional Architect-Engineering (“ERAE”) Federal contract opportunity
- Solicitation number
- 80GRC024R0006
About this file
This document contains criteria for capability statements to be submitted in response to a National Aeronautics and Space Administration Eastern Regional Architect-Engineer Sources Sought notice. Responses should be no more than ten pages and include whether the firm has federal government experience, experience working in various states including Ohio, Virginia, Florida, Alabama, Maryland, California, New Mexico, Louisiana, West Virginia, Texas and New York in the past five years, is licensed to work in those states, and has project experience in various project types including demolition, renovation and new construction of buildings, institutional high-pressure steam boilers and controls systems, cooling tower water distribution systems, telecommunications and network distribution systems, electrical distribution systems up to 38kV, storm sewer systems, process equipment and controls including cryogenic systems and instrumentation and controls systems, fire protection and detection systems, and security systems. Responses should also indicate whether the firm and key personnel have experience in architecture, civil and underground utilities, structural, mechanical including process, plumbing and HVAC, high voltage and low voltage electrical including transformers and motors, electrical protection systems, electrical controls systems, interior design, fire protection and detection, access controls and security systems, are LEED APs, have experience in master planning, cost estimating, and energy modeling, and whether the firm provides services including construction document preparation, engineering studies, field investigations, implementation and scheduling planning, energy modeling, life cycle cost analysis, cost estimating, construction phase support, LEED certification, and building information modeling.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| ERAE SS Questions Tracking Sheet - 12-15-23.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NASA Eastern Regional Architect-Engineer Sources Sought
Attachment A: Capability Statement Criteria
Responses shall not exceed ten (10) pages of 12-point font size.
Responses should minimally include items requested in the Sources Sought Notice.
Responses should also include specific YES or NO responses to the below items.
Please indicate your response below and include this attachment with your emailed response.
– YES/NO - Federal Government Experience
– YES/NO - Experience in past 5 years working in any of the following states:
▪ YES/NO - Ohio
▪ YES/NO - Virginia
▪ YES/NO - Florida
▪ YES/NO - Alabama
▪ YES/NO - Maryland
▪ YES/NO - California
▪ YES/NO - New Mexico
▪ YES/NO - Louisiana
▪ YES/NO - West Virginia
▪ YES/NO - Texas
▪ YES/NO - New York
– YES/NO - Firm is licensed/registered to perform work in any of the following states:
▪ YES/ NO - Ohio
▪ YES/NO - Virginia
▪ YES/NO - Florida
▪ YES/NO - Alabama
▪ YES/NO - Maryland
▪ YES/NO - California
▪ YES/NO - New Mexico
▪ YES/NO - Louisiana
▪ YES/NO - West Virginia
▪ YES/NO - Texas
▪ YES/NO - New York
– Project Type Experience:
▪ YES/NO - Demolition, Renovation, New Construction of Buildings
▪ YES/NO - Institutional High-Pressure Steam Boilers & Controls Systems
▪ YES/NO - Cooling Tower Water Distribution Systems
▪ YES/NO - Telecommunications/Network Distribution Systems
▪ YES /NO - Electrical Distribution Systems (LV 600V, HV>600V up to I 38kV)
▪ YES/NO - Storm Sewer Systems
▪ YES/NO - Process Equipment, Piping & Controls (cryogenic systems, high pressure air systems, vacuum systems, exhaust systems, instrumentation & controls systems)
▪ YES/NO - Fire Protection & Detection Systems
▪ YES/NO - Security Systems
NASA Eastern Regional Architect-Engineer Sources Sought
– Firm & Key Personnel Project Experience /Qualifications:
▪ YES/NO - Architecture
▪ YES/NO - Civil/Underground Utilities
▪ YES/NO - Structural
▪ YES/NO - Mechanical: Process, Plumbing, HVAC
▪ YES/NO - HV / LV Electrical: including high voltage transformers, breakers, and motors
▪ YES/NO - Electrical Protection Systems: Lightning, Grounding, Relays
▪ YES/NO - Electrical Controls Systems
▪ YES/NO - Interior Design
▪ YES/NO - Fire Protection & Detection
▪ YES/NO - Access Controls & Security Systems
▪ YES /NO - LEED AP
▪ YES/NO - Master Planning
▪ YES/NO - Cost Estimating
▪ YES/NO - Energy Modeling
– Services Provided by Firm:
▪ YES/NO - Construction Document Preparation (drawings & specs)
▪ YES/NO - Engineering Studies
▪ YES/NO - Field Investigations
▪ YES/NO - Implementation & Scheduling Planning
▪ YES/NO - Energy Modeling
▪ YES/ NO - Life Cycle Cost Analysis
▪ YES/NO - Cost Estimating
▪ YES/NO - Construction Phase Support (submittal reviews, RFI, bidding support, etc.)
▪ YES/NO - LEED Certification
▪ YES/NO - Building Information Modeling
File details come from the government source that posted it. Updated .