Attachment A 659-24-900.pdf

PDF 156 KB Posted

Attached to
C222--Correct FCA Electrical Gaps Federal contract opportunity
Solicitation number
36C24624R0035
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6

About this file

This document outlines submission requirements for 65% design development of a project to correct electrical gaps found during a facility condition assessment and modernize a Veterans Affairs medical center's electrical system. The submission must include a narrative report updating the design from 35% submission and addressing additional items in the design requirements. It must also provide construction phasing recommendations based on discussions with the program manager. The submission requires AutoCAD drawings at 1/8" scale showing equipment for each room/area, along with itemized cost estimates by specification section and criteria. It also requires custom edited VA Master Specifications and a submittal list. Accompanying the hard copy documents, the Architect/Engineer must provide the design files and specifications in digital format on an FTP site.

View the file

Other files for this federal contract opportunity

Other files attached to C222--Correct FCA Electrical Gaps, newest first.
File Type Posted
Attachment E 659-24-900.pdf PDF
Attachment C 659-24-900.pdf PDF
Attachment B 659-24-900.pdf PDF
36C24624R0035.docx DOCX document
Attachment D 659-24-900.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment A 659‐24‐900

Design Development 65% Submission Requirements

Deliver the following (labeled with 65% submission) and include this attachment as a checklist with your submission: (In addition, all submissions to be uploaded to the AE FTP site on the same day.)

2 copies of a narrative report forwarding the design developed 35% submission addressing items listed in the design requirements and any additional A/E recommendations. The report should include identifying potential bid deduct alternatives, recommended construction phasing based upon discussions with the program manager and any design calculations or analysis.

3 sets of all drawings updating all previous comments required by project produced on Auto

CAD 2013/2019. Provide 2 full size sets and 1 half size set of working drawings. Show equipment to be used in each room/area. All drawings shall be 1/8” scale.

2 copies of updated itemized cost estimate by spec section or trade (labor, material and equipment) and also by VA criteria, NRM, Minor, BSER and BSEA.

2 copies of custom edited VA Master Specifications of sections to be used for this project and a master submittal list identifying all the submittals required to be submitted by the contractor for review.

1 copy of drawings in AutoCAD 2013/2019 and in PDF and specifications in Microsoft Word 2010 on AE FTP Site

Provide 2 CDs of entire submittal package with delivery of hard copy design layouts and documents