This is a routine inspection report for the Williams River Bridge (Structure Number 092104000001010), a concrete slab bridge carrying Forest Road 135 over the Williams River in West Virginia, inspected on July 29, 2025, by the U.S. Forest Service.
The bridge, built in 1950 and located near Tea Creek Campground at mile point 0.05, is rated in Fair condition (rating F) with a lowest component condition rating of 5. The 111-foot structure consists of five concrete slab spans with a 13.5-foot curb-to-curb width, carries an estimated 25 annual average daily traffic, and is posted for load (30.0-39.9 percent below HL-93 design capacity). Key deficiencies identified include widespread CS2 moderate cracking throughout all slabs, minor delamination and spalling on the deck, approximately 4 feet of scaling on abutments and piers, and a large spalled area with exposed rebar on the upstream fascia beam. The substructure rated Satisfactory (6) with no undermining detected. Critical vulnerabilities include a very high overtopping likelihood (once every two years or more frequently), scour criticality with temporary countermeasures in place, and poor approach roadway alignment. Load ratings indicate an operating rating of 0.77 and inventory rating of 0.59 under LRFR methodology. The inspection team noted the bridge is scheduled for replacement in the 2026-2027 construction season with a new, higher structure constructed upstream, followed by full demolition of the existing bridge. A safety advisory warns that large wolf spiders inhabit all pier and abutment caps.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STRUCTURE NUMBER- 092104000001010 TEAM LEADER- Ben Shaffer
INSPECTION DATE- 07/29/2025 STRUCTURE CONDITION- F - Fair
ROUTINE INSPECTION REPORT
Structure Name WILLIAMS RIVER
Route Number 135
Structure Mile Point 0.05
Admin Org 092104
State 54 - West Virginia
County 75
Latitude 38.34084166666667
Longitude -80.23263333333334
Inspection Team Lead
Inspection Reviewer
Ben Shaffer, 08/21/2025
Jeff Dulka, 08/21/2025
© OpenStreetMap contributors
Location: ENTR. TEA CREEK C G
38.34084, -80.23263
MAP PAGE
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER Route Number: 135, Mile Point: 0.05
Structure Number: #092104000001010 / Routine
IDENTIFICATION
(1) State Names 54 - West Virginia
(8) Structure Number 092104000001010
(5) Inventory Route 1
(2) Highway Agency District
(3) County Code
(4) Place Code 0
(6) Features Intersected WILLIAMS RIVER
(7) Facility Carried FR 135
(9) Location ENTR. TEA CREEK C G
(11) Mile Point 0.04970968 mi
(12) Base Highway Network No
(13) LRS Inventory Rte & Subrte
(16) Latitude 38.34084166666667
(17) Longitude -80.23263333333334
(98) Border Bridge State Code
(99) Border Bridge Structure No.
(43) Main Structure Type 11 Material 1 - Concrete
Type 1 - Slab
(44) Approach Structure Type 00
Material 0 - Other Type 0 - Other
(45) No. of Spans in Main Unit 5
(46) No. of Approach Spans 0
(107) Deck Structure Type N - Not applicable
(108) Wearing Surface/Protective System
Type of Wearing Surface N - Not applicable (applies only to stru Type of Membrane 0 - None
STRUCTURE TYPE AND MATERIAL
0 - NoneType of Deck Protection
AGE AND SERVICE
(27) Year Built 1950
(106) Year Reconstructed 0
(42) Type of Service 15
On 1 - Highway Under 5 - Waterway
(28) Lane On 1
Under 0
(29) Average Daily Traffic 50
(30) Year of ADT 0
(109) Truck ADT %
(19) Bypass, Detour Length 98.176618 mi
CLASSIFICATION
(112) NBIS Bridge Length Y
(104) Highway System 0
(26) Functional Class 9 - Rural Local
(100) Defense Highway 0 - The inventory route is not
(101) Parallel Structure N - No parallel structure exis
(102) Direction of Traffic 3 - One lane bridge for 2 - way traffic
(103) Temporary Structure
(105) Federal Lands Highways 0 - N/A
(110) Designated National Network 0 - The inventory route is not
(20) Toll 3 - On free road. The structu
(21) Maintain 64 - U.S. Forest Service
(22) Owner 64 - U.S. Forest Service
(37) Historical Significance 4 - Historical significance is
GEOMETRIC DATA
(48) Length of Maximum Span 21.981628 ft
(49) Structure Length 110.89239199999999 ft
(50) Curb or Sidewalk Width
Left 0.9842519999999999 ft Right 0.9842519999999999 ft
(51) Bridge Roadway Width Curb to Curb 13.451443999999999 ft
(52) Deck Width Out to Out 15.419948 ft
(32) Approach Roadway Width (W/Shoulders) 14.107612 ft
(33) Bridge Median 0 - No median
(34) Skew 0 Deg
(35) Structure Flared 0 - No flare
(10) Inventory Route Min Vert Clear 99.99 ft
(47) Inventory Route Total Horiz Clear 99.081368 ft
(53) Min Vert Clear Over Bridge Rdwy 99.99 ft
(54) Min Vert Underclear 0 ft Ref:
(55) Min Lat Underclear RT
0 ft
0 ft Ref:
(56) Min Lat Underclear LT
NAVIGATION DATA
(40) Navigation Horizontal Clearance 0 ft(116) Vert-Lift Bridge Nav Min Vert Clear 0 ft(39) Navigation Vertical Clearance
(111) Pier Protection 0 - No navigation control on w(38) Navigation Control
0 ft
LOAD RATING AND POSTING
(31) Design Load A - HL93
(63) Operating Rating Method 8
(64) Operating Rating
Type 8 - Load and Resistance Factor Rating (LRF Rating 0.77
(65) Inventory Rating Method 8 - Load and Resistance Factor
(66) Inventory Rating
Type Rating 0.59
(70) Bridge Posting
(41) Structure Open/Posted/Closed P - Posted for load (may inclu
1 - 30.0 - 39.9 % below
APPRAISAL
(67) Structural Evaluation 5
(68) Deck Geometry 7
(69) Clearances, Vertical/Horizontal N
(71) Waterway Adequacy 3
(72) Approach Roadway Alignment 3 (36A) Bridge Railings (36B) Transitions 0 - Inspected feature does not meet (36C) Approach Guardrail 0 - Inspected feature does not meet (36D) Approach Guardrail Ends
(113) Scour Critical Bridges 4 - Bridge foundations determined t
0 - Inspected feature does not meet
0 - Inspected feature does not meet
PROPOSED IMPROVEMENTS
(75) Type of Work
(76) Length of Structure Improvement 0 ft
(94) Bridge Improvement Cost (Multiply value by 1000) $
(95) Roadway Improvement Cost (Multiply value by 1000) $
(96) Total Project Cost (Multiply value by 1000) $
(97) Year of Improvement Cost Estimate
(114) Future ADT 75
(115) Year of Future ADT 2045
CONDITION
(62) Culverts 6(61) Channel & Channel Protection 6(60) Substructure 5(59) Superstructure 5(58) Deck
N
INSPECTIONS *
(90) Inspection Date
(91) Frequency
(92) Critical Feature Inspection A: Fracture Critical Detail B: Underwater Inspection C: Other Special Inspection
Done Freq. (Mon) Date
* The inspection date and frequency information in this box contains the current NBI date and frequency information. Please refer to the report header for the date this inspection was conducted.
No No
07/29/2025
NBI SI&A
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
B.ID.01 Bridge Number
IDENTIFICATION
092104000001010
B.ID.02 Bridge Name WILLIAMS RIVER
B.ID.03 Previous Bridge No.
1950B.W.01 Year Built
B.L.01 State Code
B.L.02 County Code
B.L.03 Place Code
B.L.04 Highway Agency District
B.L.05 Latitude
B.L.06 Longitude
B.L.07 Border Bridge Number
B.L.08 Border Bridge State or Country Code
B.L.09 Border Bridge Insp. Resp.
B.L.10 Border Bridge Designated Lead State
B.L.11 Bridge Location
B.L.12 Metropolitan Planning Organization
LOCATION
54 - West Virginia
38.34084166666667
-80.23263333333334
N
ENTR. TEA CREEK C G
B.RH.01A Bridge Railing Type
ROADSIDE HARDWARE
B.RH.01B Bridge Railing Year (YY)
B.RH.01C Bridge Railing Test Level
B.RH.02A Transition Type
B.RH.02B Transition Year (YY)
B.RH.02C Transition Test Level
B.G.01 NBIS Bridge Length
BRIDGE GEOMETRY
B.G.02 Total Bridge Length
B.G.03 Max Span Length
B.G.04 Min Span Length
B.G.05 Bridge Width Out-to-Out
B.G.06 Bridge Width Curb-to-Curb
B.G.07 Left Curb or Sidewalk Width B.G.08 Right Curb or Sidewalk Width
B.G.09 Approach Roadway Width
15.4
13.5
14.1
B.G.14 Sidehill Bridge N - Not a sidehill bridge
B.G.15 Irregular Deck Area
1709.4B.G.16 Calculated Deck Area
B.G.10 Bridge Median
B.G.11 Skew
B.G.12 Curved Bridge
B.G.13 Max Bridge Height
0 - No median
N - Not curved
B.LR.01 Design Load
B.LR.02 Design Method
B.LR.03 Load Rating Date
B.LR.04 Load Rating Method
B.LR.05 Inventory Load RF
B.LR.06 Operating Load RF
B.LR.07 Controlling Legal Load RF
B.LR.08 Routine Permit Loads
LOADS AND LOAD RATING
HS15 - HS-15
LRFD - Load and Resistance Factor D
3/26/2020 11:00:00 AM
LRFR - Load and Resistance Factor R
0.59
0.77
1.03
Bridge does not carry routine permi
B.IR.01 NSTM Inspection Required
INSPECTION REQUIREMENTS
N - NSTM inspection not required.
B.IR.02 Fatigue Details N - No E/E’ details
B.IR.03 UW Inspection Required N - Underwater inspection not requi
N - Bridge does not have complex feB.IR.04 Complex Feature
B.C.01 Deck Condition Rating
COMPONENT CONDITION RATINGS
B.C.02 Superstructure Condition
B.C.03 Substructure Condition
B.C.04 Culvert Condition Rating
B.C.05 Bridge Railing Condition
B.C.06 Bridge Railing Transitions Condition
B.C.07 Bridge Bearings Cond.
B.C.08 Bridge Joints Condition
B.C.09 Channel Condition Rating
B.C.10 Channel Protection Condition
B.C.11 Scour Condition Rating
B.C.12 Bridge Condition Class
B.C.13 Lowest Condition Rating
B.C.14 NSTM Insp. Condition
B.C.15 UW Inspection Condition
5 - FAIR - Some moderate defec
5 - FAIR - Some moderate defec
6 - SATISFACTORY - Widespread
N - NOT APPLICABLE - Component
N - NOT APPLICABLE - Component
N - NOT APPLICABLE - Component
N - NOT APPLICABLE - Component
N - NOT APPLICABLE - Bridge do
5 - FAIR - Moderate defects; b
6 - SATISFACTORY - Widespread
6 - Widespread minor or isolat
F - Fair
5 - FAIR - Some moderate defec
N - NOT APPLICABLE - Component
N - NOT APPLICABLE - Component
B.AP.01 Appr. Roadway Alignment
APPRAISAL
B.AP.02 Overtopping Likelihood
B.AP.03 Scour Vulnerability
B.AP.04 Scour Plan of Action
B.AP.05 Seismic Vulnerability
P - Poor
6 - Very High – once every 2 years
C - Scour appraisal completed. Brid
N - A scour POA is required, but no
N - Bridge does not require seismic
B.CL.01 Owner
CLASSIFICATION
B.CL.02 Maint. Responsibility
B.CL.03 Federal or Tribal Land Access
B.CL.04 Historic Significance
B.CL.05 Toll
B.CL.06 Emergency Evacuation Designation
FL07 - U.S. Forest Service (USFS)
FL07 - U.S. Forest Service (USFS)
N - Not Applicable
7 - Historic significance of the br
N - Bridge does not carry a toll ro
N - Not an Emergency evacuation rou
SNBI SI&A
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
B.SP.02 # of Spans 5
B.SP.03 # of Beam Lines 1
CX - Concrete – otherB.SP.04 Span Material
B.SP.05 Span Continuity
B.SP.06 Span Type
B.SP.07 Span Protective System
1 - Simple or single span
S01 - Slab – solid
0 - None
B.SP.08 Deck Interaction IM - Integral or monolithic
B.SP.09 Deck Material and Type 0 - None
0 - NoneB.SP.10 Wearing Surface
B.SP.11 Deck Protective System
B.SP.12 Deck Reinforcing Protective System
B.SP.13 Deck Stay-In-Place Forms
0 - None
0 - None
0 - None
M1
SPAN SETS
B.SB.02 No. of Substructure Units 2
B.SB.03 Substructure Material C01 - Reinforced concrete – ca
A03 - Abutment – open/spill thB.SB.04 Substructure Type
B.SB.05 Substructure Protective System 0 - None
B.SB.06 Foundation Type U - Unknown
0 - NoneB.SB.07 Foundation Protective System
A1
SUBSTRUCTURE SETS
B.SB.02 No. of Substructure Units 4
B.SB.03 Substructure Material C01 - Reinforced concrete – ca
P01 - Pier – wallB.SB.04 Substructure Type
B.SB.05 Substructure Protective System 0 - None
B.SB.06 Foundation Type U - Unknown
0 - NoneB.SB.07 Foundation Protective System
P1
B.F.02 Feature Location C - Carried on bridge
B.F.03 Feature Name FR 135
7 - LocalB.H.01 Functional Classification
B.H.02 Urban Code
B.H.03 NHS Designation
B.H.04 National Highway Freight Network
99999
N - Non-NHS
N - Not on the NHFN
B.H.09 Annual ADT 25
B.H.10 Annual ADTT 5
2025B.H.11 Year of Annual ADT
B.H.12 Highway Max Usable Vertical Clearance B.H.13 Highway Min Vertical Clearance B.H.14 Highway Min Horizontal Clearance, Left
99.9
99.9
N - Not a STRAHNET routeB.H.05 STRAHNET Designation
B.H.06 LRS Route ID
B.H.07 LRS Mile Point
B.H.08 Lanes On Highway
0.05
B.H.15 Highway Min Horizontal Clearance, Right B.H.16 Highway Max Usable Surface Width
B.H.17 Bypass Detour Length
B.H.18 Crossing Bridge Number
99.9
H1
HIGHWAY FEATURES
Highway Parent B.RT.01 Route Designation
B.RT.02 Route Number B.RT.03 Route Direction B.RT.04 Route Type B.RT.05 Service Type
H1 1 135 2-T - TEMP - Two-way traffic - NS or EW 6 - Federal lands road X - Other
HIGHWAY ROUTES
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
B.F.02 Feature Location B - Below bridge
B.F.03 Feature Name WILLIAMS RIVER
N - Not navigable watersB.N.01 Navigable Waterway
B.N.02 Navigation Min Vertical Clearance
B.N.03 Movable Bridge Max Navigation Vertical Clearance
B.N.04 Navigation Channel Width
B.N.05 Navigation Channel Min Horizontal Clearance B.N.06 Substructure Navigation Protection
W1
WATERWAY FEATURES
POSTING STATUS DATA
B.PS.01 Load Posting Status B.PS.02 Posting Status Change Date
PO - Permanent - Open 08/21/2025
LOAD EVALUATION AND POSTING
B.EP.01 Legal Load Configuration B.EP.02 Legal Load Rating Factor B.EP.03 Posting Type B.EP.04 Posting Value
AASHTO Type 3 1.35
AASHTO Type 3S2 1.34
AASHTO Type 3-3 1.63
AASHTO SU6 truck 1.03
State Single Trailer 1.2
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
INSPECTION SUMMARY
Inspection Type:
Inspection Begin Date:
Inspection Completion Date:
Inspection Team Lead:
Routine
07/29/2025
07/29/2025
Ben Shaffer
A05 - WadersInspection Equipment:
Inspection Interval: 24
Latitude: 38.34084166666667
Longitude: -80.23263333333334
Region: R9, EASTERN REGION
Security ID: 0921 - MONONGAHELA NATIONAL FOREST
Inspection Team: Zoey Fox, Ben Shaffer, Leo Weese
Complex Features: N - Bridge does not have complex feature
NSTM Inspection Required: N - NSTM inspection not required.
Previous Bridge Number:
Development Status: EXISTING - ACTIVE
Structure Jurisdiction: FS - FOREST SERVICE
Inspection Responsibility: FS - FOREST SERVICE
Done By: FS - FOREST SERVICE
Fatigue Prone Details: N - No E/E’ details
Underwater Inspection Required: N - Underwater inspection not required
Bridge Condition Classification: F - Fair Lowest Condition Rating Code: 5
Inspection Remarks: Bridge to be replaced in 2026-2027 construction season. Bridge known to have large wolf spiders on all pier and abutment caps. Use caution when inspecting.
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
CONDITION & APPRAISAL DETAILS
B.C.01 Deck Condition Rating (5 - FAIR - Some moderate defects; strength and performance of the component are not affected.)
Overview:
Bridge is a slab. Per SNBI deck rates same as superstructure Structure designed to overtop
Curbing/Fascia beams:
Curbing on top broken in some areas from impact damage Upstream at span 5 large moderate spalled area with exposed rebar - this is not structural to the bridge
Topside:
Minor delamination throughout entirety of deck Small minor spalls and scaling throughout
Cleanliness:
Bridge deck clean
B.C.02 Superstructure Condition Rating (5 - FAIR - Some moderate defects; strength and performance of the component are not affected.)
Overview:
Concrete slabs have widespread moderate CS2 cracking throughout entirety Exterior fascia beams are not structural
Slabs:
CS2 cracks throughout all slabs and all spans. Most are near the pier or abutment walls. Some transverse cracks throughout at midspan.
Span 3 multiple longitudinal cracks throughout entirety as well as transverse crack throughout span 4 at pier 3 longitudinal cracking cs2
Spans:
A1 to P1 - Span 1 P1 - P4 - Spans 2,3. & 4 - this is one continuous slab but different spans P4 to A2 - Span 5 B.C.03 Substructure Condition Rating (6 - SATISFACTORY - Widespread minor or isolated moderate defects.)
Abutments:
No undermining and footers not exposed 4' high of scaling
Piers:
All piers approx. 4ft high scaling Footers not exposed and cannot poke under pier 1 span 1 side cannot fully inspect fully due to water level - area that was inspected good no undermining B.C.04 Culvert Condition Rating (N - NOT APPLICABLE - Component does not exist.)
B.C.05 Bridge Railing Condition Rating (N - NOT APPLICABLE - Component does not exist.)
Curbs do not classify as railing
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
B.C.06 Bridge Railing Transitions Condition Rating (N - NOT APPLICABLE - Component does not exist.)
B.C.07 Bridge Bearings Condition Rating (N - NOT APPLICABLE - Component does not exist.)
Bridge does not have bearings. Bridge sits directly on abutment and pier caps
B.C.08 Bridge Joints Condition Rating (N - NOT APPLICABLE - Bridge does not have deck joints.)
B.C.09 Channel Condition Rating (5 - FAIR - Moderate defects; bridge and approach roadway are not threatened.)
B.C.10 Channel Protection Condition Rating (6 - SATISFACTORY - Widespread minor or isolated moderate defects.)
B.C.11 Scour Condition Rating (6 - Widespread minor or isolated moderate scour.)
B.C.14 NSTM Inspection Condition (N - NOT APPLICABLE - Component does not exist.)
B.C.15 Underwater Inspection Condition (N - NOT APPLICABLE - Component does not exist.)
Wearing Surface Condition (NOT APPLICABLE)
No wearing surface drive directly on top of slabs
Approach Roadway Condition (GOOD)
Concrete slab approaches
B.AP.01 Approach Roadway Alignment (P - Poor)
B.AP.02 Overtopping Likelihood (6 - Very High – once every 2 years or more frequently)
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
B.AP.03 Scour Vulnerability (C - Scour appraisal completed. Bridge could become unstable for scour. Temporary (not designed) countermeasure installed to mitigate scour. Bridge is scour critical.)
B.AP.04 Scour Plan of Action (N - A scour POA is required, but not implemented.)
B.AP.05 Seismic Vulnerability (N - Bridge does not require seismic evaluation due to low anticipated ground motion or agency prioritization.)
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
STREAM CROSS SECTION
Station Remark Horizontal Distance (ft) Vertical Distance US (ft) Vertical Distance DS (ft) Abutment 1 front top of curb 2 8 9
10 10.2 10.2 21 8.6 8.9 33 7.2 5.3 43 6.8 5.5 55 7.6 6.6 65 7.1 6.8 76 7.3 6.8 87 7.8 6.4 99 7.4 6.2 109 5.5 5.3
0 20 40 60 80 100 120
Distance (ft)
El ev at io n (ft
Downstream Cross Section
0 20 40 60 80 100 120
Distance (ft)
El ev at io n (ft
Upstream Cross Section
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
Date Reported: 07/29/2025
Priority: High
Type of Work: Replace
Status: In-Progress
Remarks
Bridge is to be replaced with new structure upstream of existing structure will be fully demolished.
Component: Bridge
Deficiency Description
Bridge to be replaced in 2026-2027 construction season. Current bridge is designed to overtop. Replace bridge with new, higher structure.
MAINTENANCE ITEMS
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
CRITICAL FINDINGS
Critical Finding ID: FY21_USFS_CF18
Forest Specific Event Name:
CF Status: RO-Resolved
CF Inspection Date: 08/05/2021
CF Inspection Interval: 12
CF Found Date: 12/08/2020
Event Description/Cause (B4):
Load Rating
CF Criterion (B5): H - Posting recommended but not implemented (all signs not in-place or not correctly posted) (NBI Item 41 = B)
If Other (B5A):
Event Type/Cause (B12): Other - Please explain If Other (B12A): Insufficient Capacity during load rating
Deterioration (B13): Other - Please explain If Other (B13A): Insufficient design
Detailed Deficiency (B14): E - Undersized member If Other (B14A):
CF Results (B15): Other - Please explain If Other (B15A): Posting missing
Initial Actions (B17): Post Bridge
08/05/2021
Resolved Actions (B19): Bridge load rating determined no posting needed
03/26/2020
Future Actions (B20): HL-93 Bridge is being constructed by GAOA
10/27/2027
CF Remarks:
Construction package out to bid for new bridge. LR by Art Johnson determined no posting necessary. Will monitor during construction due to age of bridge.
Condition Summary: B.C.01 - 5 B.C.02 - 5 B.C.03 - 6 B.C.04 - N B.C.09 - 5 B.C.11 - 6
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
Structure Looking Upstream Structure Looking Downstream
Signs in place Approach 1
PHOTOS
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
Fr 86 Structure topside
Upstream Elevation
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
Spall facia beam 5 Upstream Curb Damage
Abutment 1 Spall downstream span 1
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
Spall downstream span 1 Exposed rebar chairs pier 1 Pier 2
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
Transverse crack span 3 mid span consistent throughout span 3 downstream at pier 2 cs2 cracking
Large Spiders on all Pier and Abutment Caps span 3 upstream side cs2 cracking
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER pier 3 - left
Structure Underside pier 3
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER pier 4 Abutment 2
Downstream Elevation
Team Lead: Ben Shaffer, Inspection Date: 07/29/2025
Bridge Name: WILLIAMS RIVER
File details come from the government source that posted it. Updated .