VOLUME II

ASBESTOS CONTAINING MATERIAL &

LEAD CONTAINING PAINT

SURVEY REPORT

BUILDING 62

VISN 1

Bedford VA Medical Center

200 Springs Road Bedford, Massachusetts

Project No. 2009023.008

February 15, 2011

5 Alfred Circle Bedford, MA 01730-2318

Telephone: (781) 275-6050 Toll Free: (800) 877-6050 Facsimile: (781) 275-5651 info@mabbett.com www.mabbett.com

© 2011, Mabbett & Associates, Inc.

VHABEDSanfoM Text Box Attachment 8

Bedford VAMC - Building 62 February 2011 ©2011, Mabbett & Associates, Inc. Page i Survey Report Bedford Building 62_2-15-11 FINAL.doc

ACKNOWLEDGMENT

This Asbestos Containing Materials (ACM) and Lead Containing Paint (LCP) Building Survey Report was prepared for the Veterans Affairs (VA) New England Healthcare System (VISN 1) in accordance with an established scope of work as defined in Contract Number VA241-P-1653. The information presented herein is based on the facts and information conveyed to or received by Mabbett & Associates, Inc. (M&A) during the preparation of this report. If any of the information provided to M&A that was used in preparing this report is incorrect, incomplete, or subject to change, M&A would wish to alter its opinion(s) accordingly. In addition, the professional opinions and information contained in this report are based solely on the requirements of the applicable regulations and technical data as known to M&A as of the date of this report and considered applicable to this report.

This individual building report within Volume II, which contains building specific lead and asbestos findings, is part of the Comprehensive VAMC Lead and Asbestos Survey Report consisting of the following volumes:

Volume I - General

Chapter 1 - Introduction and Executive Summary Chapter 2 - Asbestos Operations & Maintenance (O&M) Plan Chapter 3 - Asbestos Containing Materials (ACM) Survey Tables Chapter 4 - Lead Containing Paint Survey Tables

Volume II – Individual Building Reports

Individual Building Reports Chapters including:

Cover page with building number Building narrative summary Floor plans Relevant asbestos findings for the building Relevant lead containing paint findings for the building Relevant photos

Volume III – Appendices and Supporting Data

Appendix A - Asbestos Laboratory Analysis Reports and Laboratory Certifications Appendix B - Inspector Field Data Sheets/Chains-of-Custody Appendix C - Personnel Certifications & Licenses Appendix D - XRF Performance Characteristics/Calibration Records Appendix E - Lead Laboratory Analysis Reports and Laboratory Certifications (If Applicable)

Volume IV – HUD Residential LBP Reports (If Applicable)

©2011, Mabbett & Associates, Inc. Page ii Survey Report Bedford Building 62_2-15-11 FINAL.doc

This report was prepared by the following Mabbett & Associates, Inc. personnel:

Michael F. Delaney Project Manager Massachusetts Asbestos Inspector AI031436 Massachusetts Management Planner AP000048

This report has been reviewed and approved by:

MABBETT & ASSOCIATES, INC.

Robert K. McKinley, MPH, CIH, LIH Director of Industrial Hygiene Services Massachusetts Asbestos Inspector AI000314

©2011, Mabbett & Associates, Inc. Page iii Survey Report Bedford Building 62_2-15-11 FINAL.doc

TABLE OF CONTENTS

Description Page

1.0 INTRODUCTION & EXECUTIVE SUMMARY

2.0 BUILDING DESCRIPTION

3.0 ASBESTOS SURVEY

3.1 Sampling Methodology

3.2 Analytical Methodology

3.3 Summary of Asbestos Containing Materials (ACM) Findings

4.0 LEAD SCREENING SURVEY

4.1 Screening Survey Methodology

4.2 Summary of Lead Screening Survey Findings

5.0 LIMITATIONS

6.0 CLOSING REMARKS

6.1 Asbestos

6.2 Lead Containing Paint

Tables Table 1 – Specific Inaccessible Areas Table 2 – Summary of Positive ACM Samples Table 3 – Summary of XRF Measurements Above VISN 1 Threshold of >0.1 mg/cm2 Table 4 – Summary of ACM Building Survey Results, including negative results...... Appendix A Table 5 – Summary of XRF Measurements............................................................... Appendix B

Figures Figure 1 – Asbestos Survey Summary Plan - Building 62, Basement Figure 2 – Asbestos Survey Summary Plan - Building 62, Floor 1 Figure 3 – Asbestos Survey Summary Plan - Building 62, Floor 2 Figure 4 – Asbestos Survey Summary Plan - Building 62, Attic Figure 5 – Lead Survey Summary Plan - Building 62, Basement Figure 6 – Lead Survey Summary Plan - Building 62, Floor 1 Figure 7 – Lead Survey Summary Plan - Building 62, Floor 2 Figure 8 – Lead Survey Summary Plan - Building 62, Attic

Appendices Appendix A – Table 4, Summary of ACM Building Survey Results, including negative results Appendix B – Table 5, Summary of XRF Measurements Appendix C – Representative Photographs of ACM Appendix D – Representative Photographs of Non-Intact Lead Containing Paint

©2011, Mabbett & Associates, Inc. Page 1 of 9 Survey Report Bedford Building 62_2-15-11 FINAL.doc

1.0 INTRODUCTION & EXECUTIVE SUMMARY

Mabbett and Associates, Inc. (M&A), with Covino Environmental Associates, Inc. (Covino) as sub-contractors, performed surveys for suspect asbestos containing building materials (ACM) and screenings of suspect lead containing paint (LCP) surfaces utilizing an X-Ray Fluorescence (XRF) analyzer. Surveys were performed of selected buildings at the VA Medical Center (VAMC) located at 200 Springs Road, Bedford, MA, under Contract VA241-P-1653. A complete list of buildings surveyed is in Volume I of this report. Site survey work was performed in July, 2010, by appropriately credentialed personnel as required. Collected suspect ACM samples were submitted to a certified analytical laboratory for asbestos analysis by polarized light microscopy (PLM) using positive stop methodology and transmission electron microscopy (TEM) where indicated. When necessary, paint chip samples were collected and submitted to a certified analytical laboratory for lead content analysis using atomic absorption spectroscopy. The survey effort involved the collection or screening of the following samples, resulting in the following conclusions:

136 bulk samples for suspect ACM were collected in this building.

Based on laboratory analysis of suspect ACM, 16 of the collected samples contained asbestos greater than or equal to 1%.

97 XRF analyzer screening measurements of building surfaces were taken in this building.

Based on XRF screening measurements, 31 of the XRF measurements revealed concentrations of lead in paint that exceeded 0.1 milligram per square centimeter (mg/cm2).

This building report consists of a summary of findings, floor plans that indicate positive sample locations, detailed analytical findings for the specific surveyed building materials, and photos of identified ACM and LCP, greater than 1.0 mg/cm2 and in an other than intact condition.

Laboratory certificates of analysis and field data sheets for this building report are available in Volume III of the Comprehensive VAMC Lead and Asbestos Survey Report.

2.0 BUILDING DESCRIPTION

According to information provided by the VAMC Office of Facilities Management and observations made by the M&A team at the time of the survey, Building 62 was a four-story Patient Care building built in 1939 and occupied approximately 46,968 square feet.

3.0 ASBESTOS SURVEY

3.1 Sampling Methodology

A visual screening inspection was conducted to identify locations of suspect ACM throughout the building by state licensed asbestos inspectors. Only areas that were accessible during the field work phase were inspected. Every effort was made during the initial field survey work to access areas as necessary to complete the survey; however, areas that remained inaccessible to the survey team are indicated in Table 1 below.

©2011, Mabbett & Associates, Inc. Page 2 of 9 Survey Report Bedford Building 62_2-15-11 FINAL.doc

Table 1 – Specific Inaccessible Areas

Bedford VA Medical Center, Building 62

Building Floor Room

No.

Reason Area Was Inaccessible and Survey

Impacts, If Applicable

There were no inaccessible areas identified during this survey.

Other general areas that were inaccessible or where the survey was limited to visual observation only are identified below:

• Within walls • Within fire doors

• Enclosed pipe/duct chases • Inside mechanical equipment/ductwork

• Above fixed drywall or plaster ceilings

Due to these access restrictions, ACM surveys should be performed prior to any proposed renovations or maintenance involving inaccessible areas.

Bulk samples were collected of suspect ACM in accordance with US Environmental Protection Agency (EPA) Asbestos Hazard and Emergency Response Act (AHERA) and VISN 1 approved M&A VISN 1 Survey Program Standard Operating Procedure (SOP). Roofing materials were not sampled unless otherwise indicated in order to maintain applicable warranties. Bulk suspect ACM sampling was conducted according to the following sampling plan:

(a) Surfacing material:

(1) At least three bulk samples shall be collected from each homogeneous area that is 1,000 ft2 or less.

(2) At least five bulk samples shall be collected from each homogeneous area that is greater than 1,000 ft2 but less than or equal to 5,000 ft2.

(3) At least seven bulk samples shall be collected from each homogeneous area that is greater than 5,000 ft2.

(b) Thermal system insulation:

(1) At least three bulk samples shall be collected from each homogeneous area of thermal system insulation.

(2) At least one bulk sample shall be collected from each homogeneous area of patched area of thermal system insulation.

(3) Sufficient samples shall be collected from elbows and fittings to determine if it contains

ACM.

(4) Bulk samples shall not be collected from any homogeneous area where the state licensed asbestos inspector determined that the thermal system insulation is fiberglass, foam glass, rubber, or other non-ACM.

©2011, Mabbett & Associates, Inc. Page 3 of 9 Survey Report Bedford Building 62_2-15-11 FINAL.doc

(c) Miscellaneous material:

(1) At least one bulk sample shall be collected from each homogeneous area that is less than 100 ft2.

(2) At least three bulk samples shall be collected from each homogeneous area that is greater than 100 ft2.

3.2 Analytical Methodology

The collected bulk samples were submitted under chain of custody procedures to ProScience Analytical Services, Inc. (ProScience) of Woburn, MA for polarized light microscopy (PLM) analysis of bulk materials using EPA Method 600/R-93/116. When required, sample results that revealed trace concentrations (greater than 0% but less than or equal to 1%) of asbestos by PLM were analyzed using transmission electron microscopy (TEM) analysis. ProScience is accredited by the American Industrial Hygiene Association (AIHA) and participates in the National Voluntary Laboratory Accreditation Program (NVLAP Lab Code 200090-0). Duplicate bulk samples were submitted for PLM analysis to Covino. Covino is accredited by the American Industrial Hygiene Association (AIHA) and participates in the National Voluntary Laboratory Accreditation Program (NVLAP Lab Code 101781-0). A summary table containing the duplicate bulk sample results is provided in Volume I, Chapter 1, Table 4. Copies of the laboratory accreditations are included in Volume III of the Comprehensive VAMC Lead and Asbestos Survey Report.

All bulk sample results are summarized in Table 4 – Summary of ACM Building Survey Results.

The EPA, Occupational Safety and Health Administration (OSHA), and the Commonwealth of Massachusetts Division of Occupational Safety (DOS) defines any material that contains greater than one percent (>1%) asbestos as being an ACM. The Commonwealth of Massachusetts Department of Environmental Protection (DEP) defines any material that contains equal to or greater than one percent (≥1%) asbestos as being an ACM. As such, the analytical laboratory identified bulk samples as positive for asbestos that met the regulatory criteria of equal to or greater than one percent (≥1%) asbestos.

3.3 Summary of Asbestos Containing Materials (ACM) Findings

3.3.1 Data Tables, Laboratory Results, and Field Notes

Collected bulk samples confirmed by the analytical laboratory to contain ≥1% asbestos are listed in Table 2 - Summary of Positive ACM Samples. Samples analyzed by PLM containing trace levels of asbestos, defined as greater than 0% but less than 1%, are listed in Table 4 with the TEM analysis results. Volume III of the Comprehensive VAMC Lead and Asbestos Survey Report includes copies of the laboratory certificates of analysis (including duplicate samples) and Inspector Data Sheets.

©2011, Mabbett & Associates, Inc. Page 4 of 9 Survey Report Bedford Building 62_2-15-11 FINAL.doc

Table 2 - Summary of Positive ACM Samples

Estimated Quantity Sample

No.

Sample

Location

ACM

Location Description of Material

Percent and Type of

Asbestos

Amount Units

Condition

VISN 1

RISK

Hazard Category

1-4*

02A B17 02B 232

02C 131

Throughout Building

12'x12" White With Black Fleck Floor Tile

Mastic

2% Chrysotile 21,000 SF Good 4

04A 04B

04C B17 Room B17

- Office

12"x12" White With Gray Fleck Floor Tile

Mastic

5% Chrysotile 270 SF Good 4

06A B17 06B B33B 06C 219

Rooms B17, B33B, Gray Sink Undercoating 10% Chrysotile 3 EA Good 4

12A B22 12B 201B

12C 150

Throughout Building

12"x12" Tan With Brown

Streaks Floor Tile

2% Chrysotile 4,000 SF Good 4

13A B22 13B 201B

13C 150

Throughout Building

12"x12" Tan With Brown

Streaks Floor Tile Mastic

2% Chrysotile 4,000 SF Good 4

16A 16B 16C

B23 Room B23

- Boiler Room

White Duct Mastic 3% Chrysotile 100 LF Good 4

28A 238 28B Attic 28C Attic

Throughout Building

Tan Duct Mastic 5% Chrysotile 11,000 SF Good 4

31A 31B

31C

132 Room 132

- Closet

12"x12" Tan With Brown Fleck Floor Tile Mastic

5% Chrysotile 50 SF Good 4

32A 32B

32C

144 Room 144

- Closet

9"x9" Tan With Brown

Streaks Floor Tile

3% Chrysotile 50 SF Good 4

33A 33B

33C

144 Room 144

- Closet

9"x9" Tan With Brown

Streaks Floor Tile Mastic

5% Chrysotile 50 SF Good 4

36A 36B 36C

Exterior Attic Windows

Window Glazing 3% Chrysotile 80 LF Good 4

37A 37B 37C

Attic Attic Stick Pin Adhesive 10% Chrysotile 100 SF Good 4

©2011, Mabbett & Associates, Inc. Page 5 of 9 Survey Report Bedford Building 62_2-15-11 FINAL.doc

Table 2 - Summary of Positive ACM Samples Bedford VA Medical Center, Building 62

Estimated Quantity Sample

No.

Sample

Location

ACM

Location Description of Material

Percent and Type of

Asbestos

Amount Units

Condition

VISN 1

RISK

Hazard Category

1-4*

38A 38B 38C

Exterior Basement Windows

Black Window Caulking

5% Chrysotile 3,100 LF Good 4

40A 40B 40C

Exterior Exterior White Door Caulking 5% Chrysotile 200 LF Good 4

42A 42B 42C

Exterior Exterior Vent Caulking 3% Chrysotile 40 LF Good 4

43A 43B 43C

Exterior Exterior White Brick Caulking 5% Chrysotile 200 LF Good 4

Footnotes: SF - Square Feet 1 - Analyzed by TEM LF - Linear Feet EA - Each CF - Cubic Feet

* The VISN 1 risk hazard assessment scale 1 – 4 is a relative indicator of the risk and need for response/remediation. (1) represents the highest priority (e.g. removal or encapsulation) whereas a (4) represents the lowest priority (monitor as part of 6 month O&M program). The rating assigned by an Asbestos Management Planner, takes into account: condition, friable vs. non-friable, accessibility, occupancy (e.g. continuous, intermittent or occasional and patients/staff/visitors), potential for air erosion, potential for vibration damage, potential for disturbance/damage (e.g. exposed and in an accessible location), and potential for water damage.

3.3.2 Photographs

Representative photographs of identified ACM are provided in Appendix C of this report.

3.3.3 CADD Drawings

The location of each collected bulk sample and its abridged sample ID is shown on the CADD drawings in the Figures Section of this report. The sample ID on the drawings has been abridged (by excluding the individual room number from the full sample ID) for aesthetic purposes. Each positive ACM sample location is colored red and marked with an asterisk (*), while stop positives are marked with two asterisks (**). Collected bulk samples that were not positive are identified solely by the abridged sample ID. Building areas containing ACM have been indicated with hatching to identify the location of the identified ACM.

©2011, Mabbett & Associates, Inc. Page 6 of 9 Survey Report Bedford Building 62_2-15-11 FINAL.doc

4.0 LEAD SCREENING SURVEY

4.1 Screening Survey Methodology

M&A completed a Lead Containing Paint Risk Analysis in accordance with the SOP and determined that a LCP screening survey was warranted in this building. The LCP screening survey was performed by trained lead inspectors/screeners meeting the qualifications outlined in the SOP. The screening survey measured lead concentrations in accessible building surfaces by using a Niton XLp 303A XRF (serial number 18580). The XRF instrument was calibrated at the frequency specified in the SOP.

4.2 Summary of Lead Screening Survey Findings

4.2.1 Data Tables

As specified by VISN 1, a description of XRF-screened painted interior and exterior building components containing lead at concentrations greater than 0.1 mg/cm2 have been included in Table 3 below:

Table 3 - Summary of Positive XRF Measurements

Reading No.

Floor Location Substrate and Component

Side Condition Color Results

(mg/cm2)

930 Attic Main Wood Window Casing East Intact Gray 9

931 Attic Main Wood Window Sash East Intact Gray 7.3

932 Attic Main Metal Column East Intact Beige 6.7

938 Attic Elev Machine Metal Handrail West Intact Yellow 0.18

940 Attic Elev Machine Metal Door South Intact Brown 0.5

942 Attic Elev Machine Metal Tread South Intact Gray 0.5

945 Attic Stairwell Metal Stringer South Intact White 0.4 949 Attic Stairwell Metal Newel Post West Intact White 0.5 950 Attic Stairwell Wood Door West Intact Brown 0.7

954 Second 206-207 Metal Radiator Guard North Intact White 3.8

958 Second 219 Metal Radiator Guard North Intact White 5.3

973 Second Stairwell Metal Handrail West Intact White 0.4 974 Second Stairwell Metal Riser South Intact White 0.6 976 Second Stairwell Metal Newel Post East Intact White 0.7 977 Second Stairwell Metal Cage East Intact White 2.9 981 First 141 Concrete Column South Intact White 0.6

982 First 141 Metal Radiator Guard South Intact White 7.4

©2011, Mabbett & Associates, Inc. Page 7 of 9 Survey Report Bedford Building 62_2-15-11 FINAL.doc

Table 3 - Summary of Positive XRF Measurements Bedford VA Medical Center, Building 62

Reading No.

Floor Location Substrate and Component

Side Condition Color Results

(mg/cm2)

989 First 124-125 Plaster Wall (Exterior) West Intact Beige 1

990 First 124-125 Wood Door Casing West Intact White 7.9

991 First 124-125 Metal Radiator Guard West Intact White 7.7

998 First 119 Metal Radiator Guard South Intact Green 3

1015 Basement Corridor Plaster Wall (Interior) West Intact White 0.21

1016 Basement Corridor Wood Door West Intact Gray 0.6

1017 Basement Corridor Metal Door Casing West Intact Gray 1.6

1020 Basement Exterior Wood Door Casing East Intact Gray 16.8

1021 Basement Exterior Metal Lintel South Intact Gray 14.9

1023 Basement Exterior Concrete Tread South Fair Yellow 2

1026 Basement Exterior Metal Lintel North Intact Beige 21.6

1027 First Exterior Metal Handrail East Intact Brown 3 1028 First Exterior Wood Door Casing East Intact Beige 10.9

1033 Basement Exterior Metal Window Casing West Intact Beige 14.5

In addition, XRF measurements collected during the screening survey of interior and exterior building components are included in Table 5 – Summary of XRF Measurements. Table 5 includes a description of each screened surface and resulting XRF-measured lead concentration.

4.2.2 Photographs

Representative photographs of building materials greater than or equal to 1.0 mg/cm2 and where in other than intact condition (e.g. fair, peeling, cracking) are provided in Appendix D of this report.

4.2.3 CADD Drawings

Based on the results of the lead screening survey, a table of LCP components identified with > 0.1 mg/cm2 lead content was developed. This table is presented on the CADD drawings for use by the VAMC for exposure assessments and preliminary renovation planning. Based on the results of the survey, these components identified in the CADD table and on the plan should be assumed to be LCP unless otherwise determined.

©2011, Mabbett & Associates, Inc. Page 8 of 9 Survey Report Bedford Building 62_2-15-11 FINAL.doc

5.0 LIMITATIONS

This survey report is the result of a diligent search of the building for ACM and LCP. Only accessible areas were included in this survey. Although a comprehensive inspection was performed, M&A does not claim to have identified all of the ACM and LCP that could be present in the facility (for example, materials potentially located within aforementioned inaccessible areas discussed in Section 3.1). M&A’s survey was performed with limitations inherent to visual inspections. M&A has conducted this assessment with reasonable care and has performed this project within generally accepted industry standards. There can be no assurances, and M&A makes no assurances, that the information, research, and technology used to prepare this report may not change in the future, thus affecting the results reported herein.

6.0 CLOSING REMARKS

Prior to initiating plans for maintenance, renovation or demolition activities, the VAMC should review the asbestos and lead survey results to determine whether any of the materials identified as ACM or LCP will be disturbed by proposed work activities.

6.1 Asbestos

The purpose of the ACM survey was to identify ACM in the building within the limitations of the survey for worker protection purposes and future renovation or demolition planning purposes. In regards to asbestos, any suspect material encountered during renovation/demolition that is not identified in this report as being non-ACM should be assumed to be ACM unless laboratory analytical data for bulk samples prove otherwise. Suspect ACM that may be present within the walls, above inaccessible hard ceilings, or in other inaccessible locations, and that accordingly was not inspected should be assumed to contain asbestos if discovered until otherwise verified, as previously described. If ACM must be disturbed, the ACM must be removed by a licensed asbestos abatement contractor and be performed in accordance with applicable regulations. If proposed work activities will not disturb intact ACM, continuous monitoring of ACM should be conducted throughout work activities to ensure the ACM remains in an intact condition.

Additionally, prior to commencing work activities, personnel involved with the work activities should be made aware of the location of ACM, within the building in which they will be working. Additional information regarding asbestos management and the Operations & Maintenance (O&M) program is outlined in the VAMC campus wide Asbestos O&M Management Plan available in Volume I of the Comprehensive VAMC Lead and Asbestos Survey Report.

6.2 Lead Containing Paint

The purpose of the LCP screening survey was to identify patterns of LCP. For the purpose of this LCP screening survey, representative interior and exterior building components were tested. The regulations addressing LCP in non-residential buildings are focused on protecting workers involved with paint disturbing activities and related waste disposal activities.

Worker protection is regulated by OSHA regulations as well as applicable state regulations. These regulations involve air monitoring of workers to determine exposure levels when disturbing paint containing measurable lead. A LCP determination cannot determine a safe level of lead, but is

©2011, Mabbett & Associates, Inc. Page 9 of 9 Survey Report Bedford Building 62_2-15-11 FINAL.doc intended to provide guidance as to the locations of where LCP is present. VA employees and contractors may use this information to better determine exposures of workers to airborne lead by understanding the different concentrations of lead paint on representative components and surfaces. Worker exposure controls can then be implemented and air monitoring can then be performed during activities that disturb paint on representative surfaces.

A concentration of lead greater than or equal to 1.0 mg/cm2 exceeds HUD residential standards and is an indicator of risk. OSHA does not specify a safe concentration of LCP. However, for the purposes of this LCP screening survey a lead concentration greater than 0.1 mg/cm2 has been utilized as a threshold established by VISN 1 for areas where possible worker exposures may occur.

Figures

Appendix A

Table 4 Summary of ACM Building Survey Results, including negative results

Amount Units

01A B17 - 12"x12" White With

Black Fleck Floor Tile

NAD - - - -

01B 232 - 12"x12" White With

Black Fleck Floor Tile

NAD - - - -

01C 131 - 12"x12" White With

Black Fleck Floor Tile

NAD - - - -

02A B17 Throughout

Building

12'x12" White With Black Fleck Floor

Tile Mastic 2% Chrysotile 21,000 SF Good 4

02B 232 Throughout

Building

12'x12" White With Black Fleck Floor

Tile Mastic

02C 131 Throughout

Building

12'x12" White With Black Fleck Floor

Tile Mastic

03A B17 - 12"x12" White With

Gray Fleck Floor Tile

NAD - - - -

03B B17 - 12"x12" White With

Gray Fleck Floor Tile

NAD - - - -

03C B17 - 12"x12" White With

Gray Fleck Floor Tile

NAD - - - -

04A B17 Room B17 -

Office

12"x12" White With Gray Fleck Floor

Tile Mastic 5% Chrysotile 270 SF Good 4

04B B17 Room B17 -

Office

12"x12" White With Gray Fleck Floor

Tile Mastic

04C B17 Room B17 -

Office

12"x12" White With Gray Fleck Floor

Tile Mastic

05A Hallway - 2'x2' Fissured Ceiling

Tile

NAD - - - -

05B Hallway - 2'x2' Fissured Ceiling

Tile

NAD - - - -

05C Hallway - 2'x2' Fissured Ceiling

Tile

NAD - - - -

06A B17 Rooms B17, B33B, 219

Gray Sink Undercoating

10% Chrysotile 3 EA Good 4

06B B33B Rooms B17, B33B, 219

Gray Sink Undercoating

06C 219 Rooms B17, B33B, 219

Gray Sink Undercoating

07A B17 - 4" Cove Base Mastic NAD - - - - 07B 223 - 4" Cove Base Mastic NAD - - - - 07C 141 - 4" Cove Base Mastic NAD - - - - 08A B16A - Plaster Base Coat NAD - - - - 08B B02 - Plaster Base Coat NAD - - - - 08C 215 - Plaster Base Coat NAD - - - - 08D 238 - Plaster Base Coat NAD - - - -

Estimated Quantity Condition

Stop Positive See 04A

Stop Positive See 02A

Stop Positive See 06A

Table 4 - Summary of ACM Building Survey Results Bedford VA Medical Center, Building 62

Sample No.

Sample Location

ACM

Location

Description of Material

Percent and Type of

Asbestos

VISN 1

RISK

Hazard Category

1-4*

Stop Positive See 04A

Stop Positive See 02A

Stop Positive See 06A

Bedford VAMC - Building 62 ©2011, Mabbett & Associates, Inc. Page 1 of 6

February 2011 Appendix A, Table 4 - Survey Report Bedford Building 62

Estimated Quantity Condition

Table 4 - Summary of ACM Building Survey Results Bedford VA Medical Center, Building 62

Sample No.

Sample Location

ACM

Location

Description of Material

Percent and Type of

Asbestos

VISN 1

RISK

Hazard Category

1-4* 08E 241 - Plaster Base Coat NAD - - - - 08F 151 - Plaster Base Coat NAD - - - - 08G 136A - Plaster Base Coat NAD - - - - 09A B16A - Plaster Skim Coat NAD - - - - 09B B02 - Plaster Skim Coat NAD - - - - 09C 215 - Plaster Skim Coat NAD - - - - 09D 238 - Plaster Skim Coat NAD - - - - 09E 241 - Plaster Skim Coat NAD - - - - 09F 151 - Plaster Skim Coat NAD - - - - 09G 136A - Plaster Skim Coat NAD - - - - 10A B16A - Black Damp Proofing NAD - - - - 10B 234A - Black Damp Proofing NAD - - - - 10C 134A - Black Damp Proofing NAD - - - -

11A B08 - White Sink

Undercoating

NAD - - - -

11B 141A - White Sink

Undercoating

NAD - - - -

11C 141A - White Sink

Undercoating

NAD - - - -

12A B22 Throughout

Building

12"x12" Tan With Brown Streaks

Floor Tile 2% Chrysotile 4,000 SF Good 4

12B 201B Throughout

Building

12"x12" Tan With Brown Streaks

Floor Tile

12C 150 Throughout

Building

12"x12" Tan With Brown Streaks

Floor Tile

13A B22 Throughout

Building

12"x12" Tan With Brown Streaks

Floor Tile Mastic 2% Chrysotile 4,000 SF Good 4

13B 201B Throughout

Building

12"x12" Tan With Brown Streaks

Floor Tile Mastic

13C 150 Throughout

Building

12"x12" Tan With Brown Streaks

Floor Tile Mastic 14A B23 - Canvas Pipe Wrap NAD - - - - 14B B23 - Canvas Pipe Wrap NAD - - - - 14C Attic - Canvas Pipe Wrap NAD - - - - 15A B23 - Red Firestop NAD - - - - 15B 201B - Red Firestop NAD - - - - 15C 101A - Red Firestop NAD - - - -

16A B23 Room B23 -

Boiler White Duct Mastic 3% Chrysotile 100 LF Good 4

16B B23 Room B23 -

Boiler White Duct Mastic

16C B23 Room B23 -

Boiler White Duct Mastic Stop Positive See 16A

Stop Positive See 13A

Stop Positive See 12A

Stop Positive See 13A

Stop Positive See 16A

Stop Positive See 12A

Bedford VAMC - Building 62 ©2011, Mabbett & Associates, Inc. Page 2 of 6

Quantity Condition

Table 4 - Summary of ACM Building Survey Results Bedford VA Medical Center, Building 62

Sample No.

Sample Location

ACM

Location

Description of Material

Percent and Type of

Asbestos

VISN 1

RISK

Hazard Category

1-4*

17A B03 - 2'x4' Fissured Ceiling

Tile

NAD - - - -

17B 223 - 2'x4' Fissured Ceiling

Tile

NAD - - - -

17C 152 - 2'x4' Fissured Ceiling

Tile

NAD - - - -

18A B02A - 6" Cove Base Mastic ND1 - - - - 18B 108 - 6" Cove Base Mastic NAD - - - - 18C 108 - 6" Cove Base Mastic NAD - - - - 19A B01 - Pink Firestop NAD - - - - 19B B01 - Pink Firestop NAD - - - - 19C B01 - Pink Firestop NAD - - - -

20A B33B - Tan Mosaic Sheet

Flooring

NAD - - - -

20B B33B - Tan Mosaic Sheet

Flooring

NAD - - - -

20C B33B - Tan Mosaic Sheet

Flooring

NAD - - - -

21A B33B - Tan Mosaic Sheet

Flooring Mastic

NAD - - - -

21B B33B - Tan Mosaic Sheet

Flooring Mastic

NAD - - - -

21C B33B - Tan Mosaic Sheet

Flooring Mastic

NAD - - - -

22A B40 - Floor Leveling

Compound

NAD - - - -

22B B40 - Floor Leveling

Compound

NAD - - - -

22C B40 - Floor Leveling

Compound

NAD - - - -

23A B31 - Drywall NAD - - - - 23B Attic - Drywall NAD - - - - 23C B31 - Drywall NAD - - - - 24A B31 - Joint Compound NAD - - - - 24B Attic - Joint Compound NAD - - - - 24C B31 - Joint Compound NAD - - - -

25A B30A - Ceiling Plaster Base

Coat

NAD - - - -

25B 244 - Ceiling Plaster Base

Coat

NAD - - - -

25C 132 - Ceiling Plaster Base

Coat

NAD - - - -

26A B30A - Ceiling Plaster Skim

Coat

NAD - - - -

26B 244 - Ceiling Plaster Skim

Coat

NAD - - - -

26C 132 - Ceiling Plaster Skim

Coat

NAD - - - -

Bedford VAMC - Building 62 ©2011, Mabbett & Associates, Inc. Page 3 of 6

Quantity Condition

Table 4 - Summary of ACM Building Survey Results Bedford VA Medical Center, Building 62

Sample No.

Sample Location

ACM

Location

Description of Material

Percent and Type of

Asbestos

VISN 1

RISK

Hazard Category

1-4*

27A 215 - 2'x2' Textured Ceiling

Tile

NAD - - - -

27B 215 - 2'x2' Textured Ceiling

Tile

NAD - - - -

27C 215 - 2'x2' Textured Ceiling

Tile

NAD - - - -

28A 238 Throughout

Building Tan Duct Mastic 5% Chrysotile 11,000 SF Good 4

28B Attic Throughout

Building Tan Duct Mastic

28C Attic Throughout

Building Tan Duct Mastic

29A 241 - Black Sink

Undercoating

NAD - - - -

29B 241 - Black Sink

Undercoating

NAD - - - -

30A 132 - 12"x12" Tan With Brown Fleck Floor

Tile

NAD - - - -

30B 132 - 12"x12" Tan With Brown Fleck Floor

Tile

NAD - - - -

30C 132 - 12"x12" Tan With Brown Fleck Floor

Tile

NAD - - - -

31A 132 Room 132 -

Closet

12"x12" Tan With Brown Fleck Floor

Tile Mastic 5% Chrysotile 50 SF Good 4

31B 132 Room 132 -

Closet

12"x12" Tan With Brown Fleck Floor

Tile Mastic

31C 132 Room 132 -

Closet

12"x12" Tan With Brown Fleck Floor

Tile Mastic

32A 144 Room 144 -

Closet

9"x9" Tan With Brown Streaks

Floor Tile 3% Chrysotile 50 SF Good 4

32B 144 Room 144 -

Closet

9"x9" Tan With Brown Streaks

Floor Tile

32C 144 Room 144 -

Closet

9"x9" Tan With Brown Streaks

Floor Tile

33A 144 Room 144 -

Closet

9"x9" Tan With Brown Streaks

Floor Tile Mastic 5% Chrysotile 50 SF Good 4

33B 144 Room 144 -

Closet

9"x9" Tan With Brown Streaks

Floor Tile Mastic Stop Positive See 33A

Stop Positive See 31A

Stop Positive See 28A

Stop Positive See 31A

Stop Positive See 28A

Stop Positive See 32A

Stop Positive See 32A

Bedford VAMC - Building 62 ©2011, Mabbett & Associates, Inc. Page 4 of 6

Quantity Condition

Table 4 - Summary of ACM Building Survey Results Bedford VA Medical Center, Building 62

Sample No.

Sample Location

ACM

Location

Description of Material

Percent and Type of

Asbestos

VISN 1

RISK

Hazard Category

1-4*

33C 144 Room 144 -

Closet

9"x9" Tan With Brown Streaks

Floor Tile Mastic

34A 106 - Hardwood Sheet

Flooring

NAD - - - -

34B 106 - Hardwood Sheet

Flooring

NAD - - - -

34C 106 - Hardwood Sheet

Flooring

NAD - - - -

35A 106 - Hardwood Sheet Flooring Mastic

NAD - - - -

35B 106 - Hardwood Sheet Flooring Mastic

NAD - - - -

35C 106 - Hardwood Sheet Flooring Mastic

NAD - - - -

36A Interior Attic

Windows Window Glazing 3% Chrysotile 80 LF Good 4

36B Interior Attic

Windows Window Glazing

36C Interior Attic

Windows Window Glazing

37A Attic Attic Stick Pin Adhesive 10% Chrysotile 100 SF Good 4

37B Attic Attic Stick Pin Adhesive

37C Attic Attic Stick Pin Adhesive

38A Exterior Basement Windows

Black Window Caulking

5% Chrysotile 3,100 LF Good 4

38B Exterior Basement Windows

Black Window Caulking

38C Exterior Basement Windows

Black Window Caulking

39A Exterior - Expansion Joint

Caulking

NAD - - - -

39B Exterior - Expansion Joint

Caulking

NAD - - - -

39C Exterior - Expansion Joint

Caulking

NAD - - - -

40A Exterior Exterior White Door 5% Chrysotile 200 LF Good 4 40B Exterior Exterior White Door 40C Exterior Exterior White Door 41A Exterior - Stair Caulking NAD - - - - 41B Exterior - Stair Caulking NAD - - - - 41C Exterior - Stair Caulking NAD - - - - 42A Exterior Exterior Vent Caulking 3% Chrysotile 40 LF Good 4

42B Exterior Exterior Vent Caulking

42C Exterior Exterior Vent Caulking

Stop Positive See 33A

Stop Positive See 37A

Stop Positive See 38A

Stop Positive See 38A

Stop Positive See 40A Stop Positive See 40A

Stop Positive See 42A

Stop Positive See 42A

Stop Positive See 36A

Stop Positive See 36A

Stop Positive See 37A

Bedford VAMC - Building 62 ©2011, Mabbett & Associates, Inc. Page 5 of 6

Quantity Condition

Table 4 - Summary of ACM Building Survey Results Bedford VA Medical Center, Building 62

Sample No.

Sample Location

ACM

Location

Description of Material

Percent and Type of

Asbestos

VISN 1

RISK

Hazard Category

1-4* 43A Exterior Exterior White Brick 5% Chrysotile 200 LF Good 4 43B Exterior Exterior White Brick 43C Exterior Exterior White Brick

1 - Analyzed by TEM TR - Trace SF - Square Feet LF - Linear Feet EA - Each CF - Cubic Feet

Stop Positive See 43A Footnotes:

Stop Positive See 43A

* - The VISN 1 hazard assessment scale 1 – 4 is a relative indicator of the risk and need for response/remediation. (1) represents the highest priority (e.g. removal or encapsulation) whereas a (4) represents the lowest priority (monitor as part of 6 month O&M program). The rating, assigned by an Asbestos Management Planner, takes into account the following criteria:

condition, friable vs. non-friable, accessibility, occupancy (e.g. continuous, intermittent or occasional, patients/staff/visitors), potential for air erosion, potential for vibration damage, potential for disturbance/damage (e.g. exposed and in an accessible location), and potential for water damage.

NAD - No Asbestos Detected (PLM) ND - None Detected (TEM)

Bedford VAMC - Building 62 ©2011, Mabbett & Associates, Inc. Page 6 of 6

Appendix B

Table 5 Summary of XRF Measurements

930 Attic Main Wood Window Casing East Intact Gray 9 931 Attic Main Wood Window Sash East Intact Gray 7.3 932 Attic Main Metal Column East Intact Beige 6.7 933 Attic Elev Machine Block Wall (Interior) West Intact White 0 935 Attic Elev Machine Concrete Column West Intact White 0 936 Attic Elev Machine Concrete Floor West Intact Gray 0 937 Attic Elev Machine Metal Ladder West Intact Yellow 0 938 Attic Elev Machine Metal Handrail West Intact Yellow 0.18 939 Attic Elev Machine Concrete Ceiling North Intact White 0 940 Attic Elev Machine Metal Door South Intact Brown 0.5 941 Attic Elev Machine Metal Door Casing South Intact White 0 942 Attic Elev Machine Metal Tread South Intact Gray 0.5 943 Attic Stairwell Metal Tread South Intact Gray 0 944 Attic Stairwell Metal Riser South Intact White 0 945 Attic Stairwell Metal Stringer South Intact White 0.4 946 Attic Stairwell Plaster Wall (Interior) South Intact White 0 947 Attic Stairwell Plaster Ceiling South Intact White 0 948 Attic Stairwell Metal Handrail West Intact White 0 949 Attic Stairwell Metal Newel Post West Intact White 0.5 950 Attic Stairwell Wood Door West Intact Brown 0.7 951 Attic Stairwell Metal Door Casing West Intact White 0 952 Second 206-207 Plaster Wall (Exterior) North Intact White 0 953 Second 206-207 Drywall Wall (Interior) East Intact Beige 0 954 Second 206-207 Metal Radiator Guard North Intact White 3.8 955 Second 206-207 Metal Door Casing South Intact White 0 956 Second 219 Plaster Wall (Exterior) North Intact White 0 957 Second 219 Concrete Column North Intact White 0 958 Second 219 Metal Radiator Guard North Intact White 5.3 959 Second 219 Metal Door West Intact Gray 0 960 Second 219 Metal Door Casing West Intact Gray 0 961 Second 224-225 Plaster Wall (Interior) West Intact Purple 0 962 Second 224-225 Metal Radiator West Intact Purple 0 963 Second 224-225 Metal Radiator West Intact Purple 0 964 Second 224-225 Plaster Wall (Interior) South Intact Purple 0 965 Second 224-225 Metal Door Casing East Intact Gray 0 966 Second 224-225 Metal Window Casing East Intact Gray 0 967 Second 240 Metal Window Casing East Intact Beige 0 968 Second 240 Plaster Wall (Exterior) East Intact Beige 0 969 Second 240 Plaster Wall (Exterior) East Intact Beige 0 970 Second 240 Metal Radiator East Intact Beige 0 971 Second Stairwell Plaster Wall (Exterior) West Intact White 0 972 Second Stairwell Plaster Wall (Interior) South Intact White 0 973 Second Stairwell Metal Handrail West Intact White 0.4 974 Second Stairwell Metal Riser South Intact White 0.6 975 Second Stairwell Metal Stringer West Intact White 0 976 Second Stairwell Metal Newel Post East Intact White 0.7 977 Second Stairwell Metal Cage East Intact White 2.9 978 Second Stairwell Plaster Ceiling East Intact White 0

Table 5 - Summary of XRF Measurements Bedford VA Medical Center, Building 62

Color Results

(mg/cm2) Reading

No.

Floor Location

Substrate and Component

Side Condition

Bedford VAMC - Building 62 ©2011, Mabbett & Associates, Inc. Page 1 of 3

Appendix B, Table 5 - Survey Report Bedford Building 62

Table 5 - Summary of XRF Measurements

Color Results

(mg/cm2) Reading

No.

Floor Location

Substrate and Component

Side Condition

979 First 141 Plaster Wall (Exterior) South Intact White 0 981 First 141 Concrete Column South Intact White 0.6 982 First 141 Metal Radiator Guard South Intact White 7.4 983 First 141 Metal Radiator South Intact White 0 984 First 141 Plaster Wall (Interior) North Intact White 0 985 First 141 Metal Door Casing North Intact Gray 0 986 First 141 Metal Window Casing North Intact Gray 0 987 First 141 Wood Cabinet North Intact White 0 989 First 124-125 Plaster Wall (Exterior) West Intact Beige 1 990 First 124-125 Wood Door Casing West Intact White 7.9 991 First 124-125 Metal Radiator Guard West Intact White 7.7 992 First 124-125 Metal Window Casing East Intact White 0 993 First 124-125 Concrete Column East Intact Beige 0 994 First 124-125 Drywall Wall (Interior) East Intact Beige 0 995 First 124-125 Metal Door Casing East Intact Gray 0 996 First 119 Plaster Wall (Exterior) East Intact Green 0 997 First 119 Concrete Column South Intact Green 0 998 First 119 Metal Radiator Guard South Intact Green 3 999 First 119 Plaster Wall (Interior) West Intact Green 0

1000 First 119 Plaster Ceiling West Intact Green 0 1001 First Stairwell Block Wall (Exterior) West Intact White 0 1002 First Stairwell Metal Riser North Intact Gray 0 1003 First Stairwell Metal Stringer East Intact Gray 0 1004 First Stairwell Metal Handrail East Intact White 0 1005 First Stairwell Concrete Tread North Intact Gray 0 1006 First Stairwell Plaster Wall (Interior) West Intact White 0 1007 Basement B23 Concrete Wall (Exterior) West Intact White 0 1010 Basement B23 Concrete Window Sill West Intact White 0 1011 Basement B23 Concrete Column West Intact White 0 1014 Basement B23 Concrete Floor West Poor Gray 0 1015 Basement Corridor Plaster Wall (Interior) West Intact White 0.21 1016 Basement Corridor Wood Door West Intact Gray 0.6 1017 Basement Corridor Metal Door Casing West Intact Gray 1.6

1018 Basement B33b Ceramic Tile Wall

(Exterior) East Intact Blue 0

1019 Basement Exterior Metal Door East Intact Red 0 1020 Basement Exterior Wood Door Casing East Intact Gray 16.8 1021 Basement Exterior Metal Lintel South Intact Gray 14.9 1022 Basement Exterior Metal Handrail South Intact Brown 0 1023 Basement Exterior Concrete Tread South Fair Yellow 2 1024 Basement Exterior Plaster Ceiling South Intact White 0 1025 Basement Exterior Metal Handrail East Cracked Brown 0 1026 Basement Exterior Metal Lintel North Intact Beige 21.6 1027 First Exterior Metal Handrail East Intact Brown 3 1028 First Exterior Wood Door Casing East Intact Beige 10.9 1029 Basement Exterior Metal Door Casing East Intact Beige 0 1030 Basement Exterior Metal Door East Intact Red 0

Bedford VAMC - Building 62 ©2011, Mabbett & Associates, Inc. Page 2 of 3

Table 5 - Summary of XRF Measurements

Color Results

(mg/cm2) Reading

No.

Floor Location

Substrate and Component

Side Condition

1033 Basement Exterior Metal Window Casing West Intact Beige 14.5 1034 Basement Exterior Metal Pillar West Intact Yellow 0 1035 Basement Exterior Stone Curb West Fair Red 0

Black -

Blue -

Red - Greater than 1.0 mg/cm2

Font Color Annotation

Below the VISN1 Threshold of 0.1 mg/cm2

Above the VISN1 Threshold of 0.1 mg/cm2, but less than 1.0 mg/cm2

Bedford VAMC - Building 62 ©2011, Mabbett & Associates, Inc. Page 3 of 3

Appendix C

Representative Photographs of ACM

12”x12” White with Black Fleck Floor Tile Mastic Sample 02A

12”x12” White with Gray Fleck Floor Tile Mastic Sample 04A

VAMC Bedford – Building 62 February 2011 ©2011, Mabbett & Associates, Inc. Page 1 of 7 Appendix C, Survey Report Bedford Bldg 62

Gray Sink Undercoating Sample 06A

12”x12” Tan with Brown Streaks Floor Tile and Mastic Samples 12A and 13A

©2011, Mabbett & Associates, Inc. Page 2 of 7 Appendix C, Survey Report Bedford Bldg 62

White Duct Mastic Sample 16A

Tan Duct Mastic Sample 28A

©2011, Mabbett & Associates, Inc. Page 3 of 7 Appendix C, Survey Report Bedford Bldg 62

12”x12” Tan With Brown Fleck Floor Tile Mastic Sample 31A

9”x9” Tan With Brown Streaks Floor Tile and Mastic Samples 32A and 33A

©2011, Mabbett & Associates, Inc. Page 4 of 7 Appendix C, Survey Report Bedford Bldg 62

Window Glazing Sample 36A

Stick Pin Adhesive Sample 37A

©2011, Mabbett & Associates, Inc. Page 5 of 7 Appendix C, Survey Report Bedford Bldg 62

Black Window Caulking Sample 38A

White Door Caulking Sample 40A

©2011, Mabbett & Associates, Inc. Page 6 of 7 Appendix C, Survey Report Bedford Bldg 62

Vent Caulking Sample 42A

White Brick Caulking Sample 43A

©2011, Mabbett & Associates, Inc. Page 7 of 7 Appendix C, Survey Report Bedford Bldg 62

Appendix D

Representative Photographs of Non-Intact Lead Containing Paint, Greater than 1.0 mg/cm2