Attachment_7_Irrigation_Plan_IR5.pdf
PDF 2 MB Posted
- Attached to
- REPLACE IRRIGATION SYSTEM Federal contract opportunity
- Solicitation number
- 140P4321Q0037
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment_4_Irrigation_Plan_IR2.pdf | ||
| Attachment_2_General_Decision_RI20210001.pdf | ||
| Sol_140P4321Q0037.pdf | ||
| Attachment_5_Irrigation_Plan_IR3.pdf | ||
| Attachment_1_Statement_of_Work.pdf | ||
| Attachment_6_Irrigation_Plan_IR4.pdf | ||
| Attachment_3_Irrigation_Plan_IR1.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Consulting, Inc.
Providing innovative design solutions for irrigation worldwide.
Roger Williams
National Memorial
Providence, Rhode Island
National Park Service
Olmsted Center for Landscape
Preservation
Irrigation Backflow Details
PROJECT:
ROGER WILLIAMS
NATIONAL PARK
CLIENT:
NATIONAL PARK
SERVICE
DATE: 5/4/20
REVISIONS:
NO. DATE DESCRIPTION
IR- 5
AutoCAD SHX Text Huntersville, NC 28078
AutoCAD SHX Text 112 S. Old Statesville Rd., Suite 109
AutoCAD SHX Text
(704) 843.3688
AutoCAD SHX Text 20 Merrit Parkway
AutoCAD SHX Text Nashua, NH 03062
AutoCAD SHX Text
(978) 433.8972
AutoCAD SHX Text www.irrigationconsulting.com
AutoCAD SHX Text C IRRIGATION CONSULTING, INC. EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS. THESE DRAWINGS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF IRRIGATION CONSULTING, INC.
AutoCAD SHX Text
AutoCAD SHX Text MIN. 6" CLEARANCE BETWEEN HIGHEST TEST COCK AND INSIDE ROOF PANEL ENCLOSURE. WATER AUTHORITY STANDARDS.
AutoCAD SHX Text
2" LF009-QT-S WATTS RPZ W/ STRAINER
AutoCAD SHX Text MIN. 6" CLEARANCE BETWEEN PIPING AND INSIDE WALL PANEL ENCLOSURE, TYPICAL. WATER AUTHORITY STANDARDS.
AutoCAD SHX Text
2 -INCH 90 DEGREE ELBOW C X FNPT (CAST)
AutoCAD SHX Text
2-INCH COPPER CLOSE NIPPLE 2"X2"
AutoCAD SHX Text
2-INCH BRASS BALL VALVE NIBCO MODEL T-FP-600A FNPT X FNPT
AutoCAD SHX Text
2-INCH MALE ADAPTER C X MNPT (WROT)
AutoCAD SHX Text
2-INCH MALE ADAPTER C X MNPT (WROT)
AutoCAD SHX Text
2-INCH COPPER CLOSE NIPPLE 2"X2"
AutoCAD SHX Text
2 -INCH 90 DEGREE ELBOW C X FNPT
AutoCAD SHX Text
2 -INCH TYPE K COPPER PIPE
AutoCAD SHX Text
2-INCH MALE ADAPTER MNPT X C (WROT)
AutoCAD SHX Text
2-INCH BRASS BALL VALVE NIBCO MODEL T-FP-600A FNPT X FNPT
AutoCAD SHX Text
2-INCH REDUCING TEE CXCXC 2" X 2" X " (WROT) 34" (WROT)
AutoCAD SHX Text
2-INCH TYPE K COPPER PIPE
AutoCAD SHX Text 2-1/2-INCH TYPE K COPPER PIPE INSTALLED 12-INCHES BEYOND CONCRETE BASE. TRANSITION TO PVC AT THIS LOCATION INSTALLING 2-1/2" COPPER FEMALE ADAPTER (WROT) WITH 2"X12" SCH. 80 TOE NIPPLE TO IRRIGATION MAINLINE.
AutoCAD SHX Text
2-INCH TYPE K COPPER PIPE
AutoCAD SHX Text
2-INCH TYPE K COPPER PIPE
AutoCAD SHX Text
2-INCH COPPER UNION CXC (CAST)
AutoCAD SHX Text
FINISH GRADE
AutoCAD SHX Text
2-INCH TYPE K COPPER PIPE FROM METER.
AutoCAD SHX Text
4-INCH SCHEDULE 40 SLEEVE
AutoCAD SHX Text
6-INCH THICK CONCRETE PAD WITH 6-INCH GRAVEL BASE INSTALLED PER CODE
AutoCAD SHX Text
3/4-INCH GRAVEL BASE
AutoCAD SHX Text NOTE: 1. BACKFLOW ENCLOSURE SHALL BE 52" LONG X 33" TALL X 18" DEEP WITH 1-INCH FOAM INSULATION. BOX TO BE FABRICATED BY WELCH MANUFACTURING. 2. ORIENT INCOMING AND OUTGOING COPPER PIPES FROM BACKFLOW PREVENTER TO ALIGN FOR CONNECTION TO 2-INCH WATER SERVICE LINE AND OUTGOING PIPE TO CONNECT TO IRRIGATION SYSTEM. 3. INSTALL PIPE SUPPORTS FROM FLOOR BENEATH HORIZONTAL BACKFLOW PIPE RUN FOR SUPPORT. 4. INSTALL ALL EQUIPMENT PER WATER AUTHORITY CODE REQUIREMENTS.
AutoCAD SHX Text
FINISH GRADE
AutoCAD SHX Text
4-INCH SCHEDULE 40 MECHANICAL SLEEVE
AutoCAD SHX Text
4-INCH SCHEDULE 40 MECHANICAL SLEEVE
AutoCAD SHX Text
3/4-INCH GRAVEL BASE
AutoCAD SHX Text NOTE: 1. BACKFLOW ENCLOSURE SHALL BE 52" LONG X 33" TALL X 18" DEEP WITH 1-INCH FOAM INSULATION. BOX TO BE FABRICATED BY WELCH MANUFACTURING. 2. ORIENT INCOMING AND OUTGOING COPPER PIPES FROM /BACKFLOW PREVENTER TO ALIGN FOR CONNECTION TO 2-INCH COPPER WATER SERVICE LINE AND OUTGOING PIPE TO CONNECT TO IRRIGATION SYSTEM. 3. INSTALL ALL EQUIPMENT PER WATER AUTHORITY REQUIREMENTS.
AutoCAD SHX Text
CONCRETE SLAB TO BE 64-INCHES LONG X 3O-INCH WIDE X 6-INCH DEEP.
AutoCAD SHX Text
FABRICATED BACKFLOW PREVENTER ENCLOSURE WITH 1-INCH OF FOAM INSULATION
AutoCAD SHX Text NOTE: 1. BACKFLOW ENCLOSURE SHALL BE 52" LONG X 33" TALL X 18" DEEP WITH 1-INCH FOAM INSULATION. BOX TO BE FABRICATED BY WELCH MANUFACTURING. 2. CONCRETE SLAB SHALL BE 6-INCHES DEEP WITH 6-INCHES OF GRAVEL BENEATH. THE SLAB SHALL BE 3O-INCHES WIDE AND 64-INCHES LONG. 3. INSTALL ALL EQUIPMENT PER WATER AUTHORITY REQUIREMENTS.
AutoCAD SHX Text
CONCRETE BASE
AutoCAD SHX Text
3/4-INCH BRASS BALL VALVE NIBCO MODEL T-FP-600A FNPT X FNPT W/ 3/4" BRASS PLUG
AutoCAD SHX Text
3/4-INCH MALE ADAPTER C X MNPT (WROT)
AutoCAD SHX Text
3/4-INCH TYPE K COPPER PIPE
AutoCAD SHX Text
FABRICATED BACKFLOW PREVENTER ENCLOSURE WITH 1-INCH OF FOAM INSULATION
AutoCAD SHX Text
2-INCH UNION CXC (CAST)
AutoCAD SHX Text
2 -INCH COPPER MALE ADAPTER (WROT)
AutoCAD SHX Text
2-INCH 90 DEGREE ELBOW CXC (WROT)
AutoCAD SHX Text
2-INCH TYPE K COPPER PIPE
AutoCAD SHX Text
2"X2-1/2" REDUCER COUPLING [WROT (DO NOT INSTALL BENEATH PAD)]
AutoCAD SHX Text
CENTERLINE
AutoCAD SHX Text
4-INCH SCHEDULE 40 SLEEVE
AutoCAD SHX Text
BACKFLOW PREVENTER CROSS-CONNECTION AND ENCLOSURE
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
BACKFLOW PREVENTER ENCLOSURE- CONCRETE PAD PLAN VIEW
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
CONCRETE PAD FRONT PROFILE VIEW
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
| Sheets and Views |
| IR-5 |
File details come from the government source that posted it. Updated .