Attachment_6_Irrigation_Plan_IR4.pdf

PDF 2 MB Posted

Attached to
REPLACE IRRIGATION SYSTEM Federal contract opportunity
Solicitation number
140P4321Q0037
Issued by
Department of the Interior National Park Service Northeast Region

View the file

Other files for this federal contract opportunity

Other files attached to REPLACE IRRIGATION SYSTEM, newest first.
File Type Posted
Attachment_5_Irrigation_Plan_IR3.pdf PDF
Attachment_1_Statement_of_Work.pdf PDF
Attachment_7_Irrigation_Plan_IR5.pdf PDF
Attachment_3_Irrigation_Plan_IR1.pdf PDF
Attachment_4_Irrigation_Plan_IR2.pdf PDF
Attachment_2_General_Decision_RI20210001.pdf PDF
Sol_140P4321Q0037.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Consulting, Inc.

Providing innovative design solutions for irrigation worldwide.

Roger Williams

National Memorial

Providence, Rhode Island

National Park Service

Olmsted Center for Landscape

Preservation

Irrigation Details

PROJECT:

ROGER WILLIAMS

NATIONAL PARK

CLIENT:

NATIONAL PARK

SERVICE

DATE: 5/4/20

REVISIONS:

NO. DATE DESCRIPTION

IR- 4

AutoCAD SHX Text Huntersville, NC 28078

AutoCAD SHX Text 112 S. Old Statesville Rd., Suite 109

AutoCAD SHX Text

(704) 843.3688

AutoCAD SHX Text 20 Merrit Parkway

AutoCAD SHX Text Nashua, NH 03062

AutoCAD SHX Text

(978) 433.8972

AutoCAD SHX Text www.irrigationconsulting.com

AutoCAD SHX Text C IRRIGATION CONSULTING, INC. EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS. THESE DRAWINGS ARE NOT TO BE REPRODUCED, CHANGED OR COPIED IN ANY FORM OR MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY, WITHOUT FIRST OBTAINING THE EXPRESS WRITTEN PERMISSION AND CONSENT OF IRRIGATION CONSULTING, INC.

AutoCAD SHX Text

AutoCAD SHX Text WIRELESS SENSOR TO BE INSTALLED IN CONTACT WITH THE WEATHER AND NOT IN CONTACT WITH THE IRRIGATION SPRAY TO ENSURE PROPER OPERATION.

AutoCAD SHX Text

AutoCAD SHX Text

RAIN SENSOR MOUNTING DETAIL

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

EXISTING EXTERIOR BUILDING WALL

AutoCAD SHX Text

FINISH GRADE

AutoCAD SHX Text

INSTALL WIRELESS RECEIVER BESIDE THE CONTROLLER WIRE RECEIVER TO CONTROLLER.

AutoCAD SHX Text

FINISH GRADE

AutoCAD SHX Text Decoder

AutoCAD SHX Text

DBR/Y-6

AutoCAD SHX Text

DBR/Y-6

AutoCAD SHX Text

VALVE BOX

AutoCAD SHX Text

EXTENSION COIL

AutoCAD SHX Text

IRRIGATION MAIN LINE

AutoCAD SHX Text

DECODER WIRE

AutoCAD SHX Text

TO SOLENOID VALVE (TYP.)

AutoCAD SHX Text

EXTENSION

AutoCAD SHX Text

DECODER IN VALVE BOX DETAIL

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

GROUND ENHANCEMENT MATERIAL, NONMIGRATING, TOP & BOTTOM OF PLATE (1) 50 LB. BAG)

AutoCAD SHX Text

COPPER GROUND PLATE (4" X 36" X .0625")

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

10 AWG SOLID INSULATED COPPER WIRE

AutoCAD SHX Text

4" PERFORATED DRAIN PIPE WITH GRATED CAP

AutoCAD SHX Text

CONTROL CABLE

AutoCAD SHX Text

AutoCAD SHX Text

LIGHTNING ARRESTOR GROUND DETAIL

AutoCAD SHX Text CONTROL CABLE SPLICES IN VALVE BOX NEAR MAINLINE. ONE WIRE FROM SURGE DEVICE TO GROUND ROD AND PLATE. RECOMMENDED GROUND RESISTANCE AT 10 OHMS OR LESS. INSTALL SURGE ARRESTOR AT COMMUNICATION CABLE DEAD ENDS OF TRUNK CABLE OR BRANCH LINES THAT EXCEED 50 FEET. LIGHTNING ARRESTOR REQUIRED MAXIMUM EVERY 600 FT. WITH GROUND.

AutoCAD SHX Text

COPPER GROUND ROD (5/8" X 8')

AutoCAD SHX Text

BL-LA01 LIGHTNING ARRESTOR

AutoCAD SHX Text

AUTOMATIC CONTROLLER DETAIL

AutoCAD SHX Text

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

1" CONDUIT FOR 120V WIRING

AutoCAD SHX Text

JUNCTION BOX

AutoCAD SHX Text

14 AWG IRRIGATION COMMUNICATION CABLE

AutoCAD SHX Text

1-1/2" GROUND CONDUIT

AutoCAD SHX Text

AutoCAD SHX Text

CONTROLLER GROUNDING

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

METAL WATER PIPE TO EARTH.

AutoCAD SHX Text #6 SOLID COPPER WIRE ATTACHED TO GROUND STRAP. STRAP ATTACHED TO METAL WATER PIPE IN BASEMENT. RUN SOLID COPPER GROUND WIRE TO CONTROLLER IN 1-1/2-INCH ELECTRICAL CONDUIT. USE GROMMET IN CONDUIT AT WATER PIPE LOCATION.

AutoCAD SHX Text

BASEMENT ROOM WALL

AutoCAD SHX Text

CONTROLLER DOOR LOCK

AutoCAD SHX Text

METAL CABINET AND INTERNAL

AutoCAD SHX Text

TRANSFORMER MOUNTED ON

AutoCAD SHX Text

AUTOMATIC CONTROLLER W/

AutoCAD SHX Text HUNTER WIRELESS RAIN-CLIK WITH SENSOR GUARD TO BE INSTALLED ABOVE STORAGE SHED DOOR.

AutoCAD SHX Text

TWO-WIRE CABLE

AutoCAD SHX Text

LIGHTNING ARRESTOR

AutoCAD SHX Text

RED

AutoCAD SHX Text

WHITE

AutoCAD SHX Text

GREEN TO GROUND

AutoCAD SHX Text

GROUNDING SHALL NOT EXCEED 10 OHMS FROM ANY

AutoCAD SHX Text

ELECTRICAL DEVICE OR WIRE TO EARTH GROUND.

AutoCAD SHX Text

GROUND SHALL BE A MINIMUM OF 10 FEET FROM

AutoCAD SHX Text

LIGHTNING ARRESTOR DETAIL

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

LIGHTNING ARRESTOR

AutoCAD SHX Text

PROVIDE AND INSTALL LIGHTNING ARRESTORS AS PER MANUFACTURE RECOMMENDATIONS.

AutoCAD SHX Text PROVIDE LIGHTNING ARRESTORS, ONE AT THE CONTROLLER, EVERY 600FT. MAXIMUM ON THE COMMUNICATION CABLE, AT THE ENDS OF THE MAINLINE RUNS AND ANY BRANCH OVER 50FT FROM THE MAINLINE.