8.00" MIN.
CONCRETE
36.00" SQUARE
MIN. WIDTH
9.50"
9.50"
CONCRETE PAD
14" MIN
I
REVISION
REV H - REMOVE TABLE W/ AMP RATINGS &
ADD NOTE 3 W/ AMP RATINGS
REV I - UPDATE DRAWING WITH 2 PAGES
ECO# 2522
REV. DESCRIPTION:
61-903
DRAWING NO:
ENCLOSED
PEDESTAL INSTALLATION
SYSTEM VI
DRAWING NAME:
SHEET:
1 TO 1
SCALE:
2/09/21
VFW
DATE:
DATE:
DATE:
APPROVALS
DRAWN BY:
CHECKED BY:
APPROVED BY:
± 1°
ANGLES
.XX ± .030
.XXX ± .015
DECIMALS
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
& TOLERANCES ARE:
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION WHICH SHALL NOT BE REPRODUCED, DISCLOSED TO OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE WITHOUT WRITTEN PERMISSION FROM VENTEK INTERNATIONAL.
InternationalVenTek
NOTES:
1. THE POWER AND PHONE LINES SHOULD EACH BE
RUN IN INDIVIDUAL PVC CONDUITS. IN ADDITION,
THE NETWORK LINE RUNNING IN SHOULD BE RUN
IN SEPARATE PVC CONDUITS.
2. BEFORE INSTALLING THE PEDESTAL, BE SURE
ALL POWER AND COMMUNICATION LINES HAVE
BEEN RUN IN SEPARATE CONDUIT.
3. AT 110/220V @20A CIRCUIT IS REQUIRED FOR
EACH PAY STATION.
CONC. PAD SPECIFICATIONS
4X REBAR
1/2" MIN
12" SQUARE
NOTE:
LEAVE SEVERAL FEET OF WIRE EXTENDING OUT OF THE
CONDUIT TO ENSURE EASY HOOKUP TO SYSTEM VI.
FRONT
USE CONDUIT PER ELECTRICAL CODE
SEE SHEET 2 FOR LENGTH
DRILL A Ø.625 (4PLCS)
ONLY WHEN A WEDGE
STUD ANCHOR IS USED
(5/8-11 X 6.00)
4.75"
CONDUIT
LOCATION
CONCRETE (REF)
FIGURE B
USE L-HOOK ANCHOR BOLTS
(MCM P/N 91587A310)
WHEN POURING NEW CEMENT
5/8-11 X 8.00
FIGURE A
USE WEDGE ANCHOR BOLTS
(MCM P/N 97110A452)
WHEN CEMENT ALREADY EXISTS
5/8-11 X 6.00
USE THIS DIMENSION FOR
BOTH L-HOOK ANCHOR BOLT
AND WEDGE ANCHOR BOLT
1.750"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1260 HOLM ROAD, SUITE A, PETALUMA, CA 94954 TEL. (707) 773-3373 FAX (707) 773-3381
AutoCAD SHX Text engineering the future of automated payment systems
AT LEAST 1.00" BELOW SURFACE
CROSS-SECTION
ELECTRICAL
CONDUIT
DETAIL B
SCALE 1 : 2
PEDESTAL MOUNTING HARDWARE:
(4x) 5/8-11 HEX NUT
(4x) 5/8" SAE FLAT WASHER
(4x) 5/8" LOCK WASHER
GROUND
PEDESTAL
(INSIDE)
M600/SVI
CONCRETE PAD
4X 1/2-13 HEX BOLT
4X 1/2 ID WASHER
DETAIL B
DIM A P/N DESCRIPTION
12"
04-370-01 ADA W/ CURB
18" 04-370-02 ADA W/O CURB
24" 04-370-03 WALK UP OR DRIVE UP W/ CURB
30" 04-370-04 WALK UP OR DRIVE THRU SURFACE
35" 04-370-05 DRIVE THRU
I
REVISION
REV H - REMOVE TABLE W/ AMP RATINGS &
ADD NOTE 3 W/ AMP RATINGS
REV I - UPDATE DRAWING WITH 2 PAGES
ECO# 2522
REV. DESCRIPTION:
61-903
DRAWING NO:
ENCLOSED
PEDESTAL INSTALLATION
SYSTEM VI
DRAWING NAME:
SHEET:
1 TO 1
SCALE:
2/09/21
VFW
DATE:
DATE:
DATE:
APPROVALS
DRAWN BY:
CHECKED BY:
APPROVED BY:
± 1°
ANGLES
.XX ± .030
.XXX ± .015
DECIMALS
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
& TOLERANCES ARE:
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION WHICH SHALL NOT BE REPRODUCED, DISCLOSED TO OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE WITHOUT WRITTEN PERMISSION FROM VENTEK INTERNATIONAL.
InternationalVenTek
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1260 HOLM ROAD, SUITE A, PETALUMA, CA 94954 TEL. (707) 773-3373 FAX (707) 773-3381
ANCHOR BOLT TEMPLATE
SCALE 1 : 1
9.5" SQUARE
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION WHICH SHALL NOT BE REPRODUCED, DISCLOSED TO OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE WITHOUT WRITTEN PERMISSION FROM VENTEK INTERNATIONAL.
I
R E
V I S
I O
N
R E
V
D
E S
C R
I P
T I O
N
D R
A W
I N
G
N
O
E N
C L
O S
E D
P E
D E
S T
A L
I N
S T
A L
L A
T I O
N
M
D R
A W
I N
G
N
A M
E
O
F
S H
E E
T
T
O
S C
A L E
V F
W
D A
T E
D A
T E
D A
T E
A P
P R
O V
A L S
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
A P
P R
O V
E D
B
Y
A N
G L E
S
X
X
D E
C I M
A L S
U N
L E
S
O
T H
E R
W I S
E
S
P E
C I F
I E
D
D I M
E N
S I O
R
C H
E S
T
O L E
R A
N C
R E
I n t e r n a t i o n a l
V e n T e k
S E
E
S
H E
T
WHEN CEMENT ALREADY EXISTS
DRILL Ø.625 (4PLCS)
FOR WEDGE ANCHOR BOLTS
(5/8-11 X 6.00)
SEE FIGURE A, SHT1
CONDUIT
LOCATION
4.75"
WHEN POURING NEW CEMENT
INSTALL L-HOOK ANCHOR BOLTS
(4PLCS, 5/8-11 X 8.00)
SEE FIGURE B, SHT1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1260 HOLM ROAD, SUITE A, PETALUMA, CA 94954 TEL. (707) 773-3373 FAX (707) 773-3381
25.0
34.0
57.3
A
B C
E
F
12" X 12" A
PEDESTAL
17.1 D
* ADA COMPLIANT HEIGHT (48" MAX.)
PEDESTAL OPTIONS
PEDESTAL
HEIGHT
(A)
ADA HEIGHT
(B)
MACHINE
HEIGHT
WITHOUT SOLAR
(C)
SOLAR MOUNT
(D)
OVERALL HEIGHT
WITH SOLAR
(E)
COIN CUP
HEIGHT
(F)
12" 40" * 46" 32" 68" 19.4" 18" 46" * 52" 38" 74" 25.4" 24" 52" 58" 44" 80" 31.4" 30" 58" 64" 50" 86" 37.4"
VenTek International engineering the future of automated payment systems
1260 HOLM ROAD, SUITE A, PETALUMA, CA 94954
TEL. (707) 773-3373 FAX (707) 773-3381
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION WHICH SHALL NOT BE REPRODUCED, DISCLOSED TO OTHERS, USED FOR MANUFACTURING OR ANY OTHER PURPOSE WITHOUT WRITTEN PERMISSION FROM VENTEK INTERNATIONAL.
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
& TOLERANCES ARE:
DECIMALS
.XX .030
.XXX .015
ANGLES
DRAWN BY:
CHECKED BY:
APPROVED BY:
APPROVALS
DATE:
DATE:
DATE:
MCR 3/13/2018
--SCALE: 1 TO 12 SHEET SIZE: B
DRAWING NAME:
OVERALL DIMENSIONNING
M600 WITH PEDESTAL
AND SOLAR OPTION
DRAWING NO:
61-910
REV. DESCRIPTION:
ADD COIN CUP HEIGHT
ECO# 2050
REVISION
C
FILE LOCATION: DP/M600 TOP ASSY
3D FILENAME: 61-910 M600 With Solar & PedestalSHEET: 1 OF 1
FOREST SERVICE AUTOMATED FEE MACHINE: Clear Creek Information Station Los Angeles Gateway Ranger District, Angeles National Forest
NOT TO SCALE
FEE MACHINE LOCATION
SOUTH FACING
krosado Callout
San Gabriel Canyon Gateway Center
Automated Fee Machine – Siting
Recommendations
November 29, 2021 - UPDATED February 3, 2022
By
Jose Henriquez
Forest Landscape Architect
Angeles National Forest
San Gabriel Canyon Gateway Center
Proposed Fee Station Drive-Up Location
Fee Station Specs
Considering the varying heights of the working components on these machines, and the different vehicle heights, accessibility factors, and transportation guidelines, none of the above pedestal options met all the criteria. However, the option that is being recommended seems to be the one that came closest.
These dimensions were chosen based on the following factors:
• The fee station will be installed on an existing island with a curb that is 6 inches above the road, so that will add an additional 6 inches to overall height of the fee station
• Window heights between sedans and SUVS range from 39-48 inches – Based on measuring window edges on several standard vehicles in SO parking lot
• Department of Transportation requires that the ticket dispensing component of their Automatic Ticket Issuing Machines/Automatic Coin Machines be installed a height of 3 feet above the travel lane surface.
• “Controls and operating mechanisms must comply with the requirements for reach ranges and operability specified in ABAAS, sections 308 and 309 whenever a site feature has buttons, knobs, handles, or other controls or operating devices. One of the basic principles of universal design and accessibility is to provide controls that most people can reach and use.
o Obstructed* Side Reach—For side reaches, obstructions must not be more than 34 inches (865 millimeters) high or 24 inches (610 millimeters) deep. The object to be reached is not allowed to be under the obstruction. If the reach depth is 10 inches (255 millimeters) or less, the object to be reached must be 48 inches (1,220 millimeters) or less above the ground or floor (figure 54). If the reach depth is between 10 and 24 inches (255 and 610 millimeters), the object to be reached must not be more than 46 inches (1,170 millimeters) above the floor or ground (figure 55).*The car door will be the obstruction in this case, but keep in mind that the height at which the driver will be sitting will vary compared to the height of sitting on a wheelchair
Fee Station Installation
• There is supposed to be power on site, but for now a solar panel will be needed
• Center the Fee Station along the edge on the island closest to the San Gabriel Canyon
Gateway Center o Lat 34° 9'33.81"N, Long 117°54'32.45"W – Approximate Location
• The concrete base should be flush and leveled with the existing inside edge of the existing curb on the side of the island that is closest to the Visitor Center entrance, per simulated image below.
• Operational face of Fee Station cannot be more than 24 inches away from the outside edge of the concrete curb