Attachment 7 1M16 Molder-bulker meat.docx
DOCX document 36 KB Posted
- Solicitation number
- HQC00423Q0035
- Issued by
-
Defense Commissary Agency
About this file
This document outlines the minimum acceptable standards for a 1M16 Molder/Bulker meat equipment attachment. The attachment is used to precisely portion ground meat into loaves for sales floor display. It attaches to and operates in tandem with a main mixer/grinder unit. Key features include an automatic paper feed unit to insert separators between molded meat blocks, the ability to portion 8 to 32 ounce loaves, and removable power and extrusion units for cleaning. Safety and sanitation certifications are required. Electrical specifications are provided for standard U.S. and Pacific Theater stores. The contractor must provide parts support for five years beyond the equipment lifespan. Related preventive maintenance and unscheduled repair services for miscellaneous food processing equipment are solicited by the Defense Commissary Agency.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 12 4SMA Slicer Meat Automatic.docx | DOCX document | |
| Attachment 9 1M20-A Mixer Grinder Systems.docx | DOCX document | |
| Attachment 1 MFP Group 59 Equipment Listing.pdf | ||
| Attachment 5 1D09 Rotisserie Oven.docx | DOCX document | |
| Attachment 10 1M34 Tenderizer Meat.docx | DOCX document | |
| Attachment 13 Performance Work Statement.pdf | ||
| Attachment 11 1M37 Horizontal slicer meat cleaver.docx | DOCX document | |
| Attachment 8 1M18 Band Saw Meat.docx | DOCX document | |
| Attachment 14 MFP Group 59 CLIN Pricing.xlsx | XLSX spreadsheet | |
| Attachment 4 1B20 Proofer Roll-In.docx | DOCX document | |
| Attachment 3 1B15 Oven Mini-Rotary with Proofer.docx | DOCX document | |
| Attachment 6 1M10 Conveyor.docx | DOCX document | |
| Attachment 2 1B12-A Oven Roll-in Single Rack Electric.docx | DOCX document |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INITIATED
04/19/16
CED
MEAT
DEPARTMENT
Minimal Acceptable Standards
REVISION
08/31/2022
| 1M16 |
| Molder / Bulker, Meat Attachment |
| PAGE 2 of 4 |
Purpose of this Equipment: To precisely portion ground meat into loaves for sales floor display
1 Federal Supply Class: 7320
2 General Operating Specifications:
2.1 Dimensions:
2.1.1 N / A
2.2 Salient Characteristics that shall be provided:
2.2.1 Height adjustable stand
2.2.2 Attaches to and operates in tandem with main mixer / grinder unit (CED 1M20)
2.2.3 Automatic paper feed unit inserts a paper separator between each square or molded meat block
2.2.4 Portions 8 to 32 ounce loaves of ground meat
2.2.5 Power unit, conveyor, knife and guide, extrusion die and adapter removable for cleansing
2.2.6 Safety interlock switch disengages motor when power unit is removed
2.2.7 Molder / bulker connects to mixer / grinder by means of adapter
2.2.8 Shall accommodate size 32, size 42, or size 52 adapter to operate in tandem with various mixer / grinder manufacturers
2.3 Industry Standards / Requirement(s):
2.3.1 Industry Standards: Underwriters Laboratory (UL) listed and National Sanitation Foundation (NSF) certification, or approved equivalent. Conformité Européene (CE) is not acceptable for a standard.
2.3.2 Warranty period shall be for (1) year from date of delivery against defective material and workmanship and shall include parts, service and labor.
2.4 Information Technology requirements: N / A
2.5 Color Requirement(s): N / A
3 Electrical Requirements:
3.1 _____ Standard U.S.A. electrical specifications: 115 volts, 60 Hertz, 1 phase.
3.2 _____ Pacific Theater stores 120 / 220 V / 50 HZ / 1 PH (Applies to these stores only: Atsugi, Misawa, Sagami, Sagamihara, Yokosuka, Yokota, Camp Zama, and Kanto Plains CDC. All other stores are standard U.S.A. 60 cycle voltages.).
3.3 Minimum 6-foot cord with a NEMA Standard plug, or a manufacturer’s equivalent to comply with the equipment plug in requirements.
3.4 NOTE: the operating range for 120 volts is 110 to 120 volts; the operating range for 220 volts is 208 to 230 volts.
Standard Contractor Requirements:
3.5 Must be shipped ready to assemble, plug in, and use
3.6 This equipment requires disposal: place in a specified area
3.7 Information to be provided by the Contractor to the commissary at the time of delivery:
3.7.1 Point of Contact for Service
3.7.2 Installation and Operating Instructions
3.7.3 Parts List
3.8 Maintenance Sustainability Requirements: Continued parts support is required for the projected life cycle of the equipment plus 5 years.
Special Coordinating / Safety Instructions: N / A
STORE ORDER REQUEST
STORE NAME: __________________________ DODAAC: ____________________
QUANTITY: _______
1) OTHER EQUIPMENT OPTIONS:
_____ Size 32 adapter _____ Size 42 adapter _____ Size 52 adapter
FY16r.05 image1.jpg