Attachment 5 Validation Sheeting Colors and Reflective Characteristics.pdf
PDF 197 KB Posted
- Solicitation number
- 300000268111710
- Issued by
- Missouri
About this file
This is a technical specification attachment establishing validation sheeting retroreflective characteristics standards for a state or local contract opportunity. The document specifies minimum coefficient of retro-reflection values that validation sheeting must meet, measured at a 0.2 degree observation angle and expressed in candelas per lux per square meter. Testing must be conducted in accordance with ASTM E-810, "Standard Test Method for Coefficient of Retro-reflection of Retro-reflective Sheeting," on flat, clean material samples. The specification includes retroreflective performance requirements across multiple colors at three entrance angles: -4 degrees, 40 degrees, and 50 degrees. Color requirements are provided for white, yellow, purple, green, blue, red, orange (neon), black, lime green, and pink (neon) sheeting.
The document establishes minimum candlepower performance thresholds that vary by color and entrance angle, with white sheeting requiring the highest retroreflection values (50, 15, and 30 candelas per lux per square meter at the respective angles) and black sheeting requiring the lowest values (6, 2, and 3 candelas per lux per square meter). These specifications ensure that validation sheeting meets established retroreflective standards necessary for visibility and safety applications. The attachment does not contain pricing information, award dates, contract terms, or other administrative details related to the procurement opportunity.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT 1
VALIDATION SHEETING RETROREFLECTIVE CHARACTERISTICS
The Coefficient of Retro-reflection shall be measured on flat, clean validation sheeting and shall have the following minimum values at 0.2 degrees observation angle, expressed as candlepower per foot-candle per square foot (candelas per lux per square meter) of material. Measurements shall be conducted in accordance with ASTM E- 810, “Standard Test Method for Coefficient of Retro-reflection of Retro-reflective Sheeting”.
Color Entrance Angles
-4 degrees 40 degrees
50 15
30 8
28 11
28 8
14 5
10 3
6 2
30 10
24 8
White
Yellow
Purple
Green
Blue
Red
Orange (neon)
Black
Lime Green
Pink (neon) 12 3