Attachment 5 - Preview Board Drawing.pdf
PDF 144 KB Posted
- Attached to
- Warrior Restaurant BLDG 7011 Drive-Thru Upgrade Federal contract opportunity
- Solicitation number
- Amendment_01_W911RX-23-Q-0010
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 2 - Davis-Bacon Act WD(KS20230056_14APR2023)23-Q-0010.pdf | ||
| Attachment 3 - Menu Board Drawing.pdf | ||
| Amendment 01 RFQ (Warrior Restaurant Upgrade) 23-Q-0010.pdf | ||
| Attachment 4 - Canopy Drawing.pdf | ||
| Attachment 6 - Clearance Bar Drawing.pdf | ||
| Attachment 8 - Questions and Answers from Solicitation 23-Q-0010.pdf | ||
| Attachment 1 - SOW (Warrior Restaurant Drive-Thru Upgrade 23-Q-0010.pdf | ||
| Attachment 7 - Project Overview.pptx | PPTX presentation |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DT FLEX 2 5-17-19
SEE DIAGRAM S OR T
FORMED
18.5 X 11.25 X 10 GAUGE
ASTM A-500 Gr. B
8.00
8.00
30Ā
R.44 12.25
18.50
4.00
4.50
7.00
1.75
7/8” (4) RADIAL SLOTS FOR 3/4”
ASTM GR. 55 ANCHOR BOLTS
BASE PLATE DETAIL
3/4” ASTM A-36 STEEL
2-5 3/16 FILLET
5 PLACES
FRONT VIEW
4.00
5.75
11.25
12.25
1.65
17.00
MENU CABINET
PEDESTAL
4” X 4” X3/16” TUBE ASTM A-500 GR B
11 GAUGE FORMED ASTM A-500 GR B
4X .625” THRU HOLES FOR 1/2-13 ASTM A-325 BOLTS
59.37
3.44
27.87 27.87
G
TYP
3/16
TYP
54.62
4.00
.120
TYP
.135
MOUNTING
PLATE
.06
ACCESS COVER ONLY
DETAIL B
SCALE 1 : 2
4X 1/2" BOLTS THRU ALL TO WELD NUTS
ELECTRICAL
ACCESS
CUT AWAY VIEW PEDESTAL TO CABINET CONNECTION
DT FLEX 3 5-17-19