Attachment 5 - Electrical Load Analysis AC Distribution.xlsx
XLSX spreadsheet 269 KB Posted
- Attached to
- 60' Dive Support Boat Federal contract opportunity
- Solicitation number
- N6426724Q5020
About this file
This document includes an electrical load analysis spreadsheet and details of a solicitation for a 60-foot dive support boat. The electrical load analysis spreadsheet provides technical specifications and power requirements for equipment onboard the vessel for various operational profiles. The solicitation seeks offers for a 60-foot dive support boat to be awarded as a single contract. Offerors must be registered in SAM and eligible to submit responses by the deadline specified on the website where the solicitation is posted. The boat must support dive operations and accommodate shore transit, with electrical power needs analyzed for summer and winter conditions.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 14 - CLIN Pricing Chart_v1.xls | XLS spreadsheet | |
| N6426724Q5020_Amendment3.pdf | ||
| N6426724Q5020_Amendment2.pdf | ||
| N6426724Q5020_Amendment1.pdf | ||
| Attachment 2 - 60DS Spec Response Matrix.xlsx | XLSX spreadsheet | |
| Attachment 6 - Unique Item Identification.pdf | ||
| Attachment 7 - Initial Spare Parts List.xlsx | XLSX spreadsheet | |
| N6426724Q5020_Combined Synopsis-Solicitation.pdf | ||
| Attachment 9 - Warranty Terms.docx | DOCX document | |
| Attachment 10 - Delivery Schedule.xlsx | XLSX spreadsheet | |
| Attachment 11 - Technical Data Rights Assertion.docx | DOCX document | |
| Attachment 12 - Past Performance and Experience.docx | DOCX document | |
| Attachment 14 - CLIN Pricing Chart.xls | XLS spreadsheet |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sample AC EPLA
| Summer Conditions | Winter Conditions | |||||||||||||||||||
| Shore | Transit | Dive Operations | Shore | Transit | Dive Operations | |||||||||||||||
| Description | Supplier | OEM P/N | Qty | Phase | Volts | Amps | PF | Attached Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) |
| 240VAC Loads | ||||||||||||||||||||
| Stbd #4 Main Cabin HVAC * | 1 | 1 | 240 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Pilothouse HVAC ** | 1 | 1 | 240 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| D.E.R. 240VAC Receptacle | 1 | 1 | 240 | 0.1 | 0.1 | 0.1 | 0.1 | 0.3 | 0.3 | |||||||||||
| Water Heater | 1 | 1 | 240 | 0.3 | 0.1 | 0.3 | 0.3 | 0.1 | 0.3 | |||||||||||
| Port #1 Main Cabin HVAC * | 1 | 1 | 240 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Stbd #3 Main Cabin HVAC * | 1 | 1 | 240 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Aft Deck 240VAC Receptacle #1 | 1 | 1 | 240 | 0.1 | 0.1 | 0.1 | 0.1 | 0.3 | 0.3 | |||||||||||
| Aft Deck 240VAC Receptacle #2 | 1 | 1 | 240 | 0.1 | 0.1 | 0.1 | 0.1 | 0.3 | 0.3 | |||||||||||
| Aft Deck 240VAC Receptacle #3 | 1 | 1 | 240 | 0.1 | 0.1 | 0.1 | 0.1 | 0.3 | 0.3 | |||||||||||
| Main Cabin 240VAC Receptacle | 1 | 1 | 240 | 0.1 | 0.1 | 0.1 | 0.1 | 0.3 | 0.3 | |||||||||||
| Engine Ventilation Exhaust Fan | 1 | 1 | 240 | 0.1 | 1.0 | 1.0 | 0.1 | 1.0 | 1.0 | |||||||||||
| Port #2 Main Cabin HVAC * | 1 | 1 | 240 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Port #1 Main Cabin HVAC Heat Module | 1 | 1 | 240 | 0.0 | 0.0 | 0.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Port #2 Main Cabin HVAC Heat Module | 1 | 1 | 240 | 0.0 | 0.0 | 0.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Stbd #3 Main Cabin HVAC Heat Module | 1 | 1 | 240 | 0.0 | 0.0 | 0.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Stbd #4 Main Cabin HVAC Heat Module | 1 | 1 | 240 | 0.0 | 0.0 | 0.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Pilothouse HVAC Heat Module | 1 | 1 | 240 | 0.0 | 0.0 | 0.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Galley HVAC *** | 1 | 1 | 240 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Galley HVAC Heat Module | 1 | 1 | 240 | 0.0 | 0.0 | 0.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Dive Room Exhaust Fan | 1 | 1 | 240 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Dive Room Intake Fan | 1 | 1 | 240 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Fresh Water Pump | 1 | 1 | 240 | 0.1 | 0.2 | 0.5 | 0.1 | 0.2 | 0.5 | |||||||||||
| HVAC Sea Water Pump | 1 | 1 | 240 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | |||||||||||
| LP Compressor | 1 | 1 | 240 | 0.1 | 0.2 | 0.5 | 0.1 | 0.2 | 0.5 | |||||||||||
| Black Water Discharge Pump | 1 | 1 | 240 | 0.1 | 0.0 | 0.0 | 0.1 | 0.0 | 0.0 | |||||||||||
| 120VAC Loads | ||||||||||||||||||||
| Port Engine Block Heater | 1 | 1 | 120 | 0.1 | 0.0 | 0.0 | 0.6 | 0.0 | 0.0 | |||||||||||
| Stbd Engine Block Heater | 1 | 1 | 120 | 0.1 | 0.0 | 0.0 | 0.6 | 0.0 | 0.0 | |||||||||||
| Port Generator Block Heater | 1 | 1 | 120 | 0.1 | 0.0 | 0.0 | 0.6 | 0.0 | 0.0 | |||||||||||
| Stbd Generator Block Heater | 1 | 1 | 120 | 0.1 | 0.0 | 0.0 | 0.6 | 0.0 | 0.0 | |||||||||||
| Engine Room Heater | 1 | 1 | 120 | 0.0 | 0.0 | 0.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Engine Room Receptacles | 2 | 1 | 120 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | |||||||||||
| Lazarette Receptacles | 1 | 1 | 120 | 0.1 | 0.0 | 0.0 | 0.1 | 0.0 | 0.0 | |||||||||||
| Lazarette Fan | 1 | 1 | 120 | 0.1 | 0.5 | 0.5 | 0.1 | 0.5 | 0.5 | |||||||||||
| Window Defogger / Head Recpt | 5 | 1 | 120 | 0.0 | 0.1 | 0.1 | 0.0 | 0.5 | 0.2 | |||||||||||
| Fwd Ventilation Fan | 1 | 1 | 120 | 0.1 | 0.5 | 0.5 | 0.1 | 0.5 | 0.5 | |||||||||||
| Galley Receptacles | 4 | 1 | 120 | 0.1 | 0.5 | 0.5 | 0.1 | 0.5 | 0.5 | |||||||||||
| Exterior Deck Lighting | 14 | 1 | 120 | 0.1 | 0.5 | 0.5 | 0.1 | 0.5 | 0.5 | |||||||||||
| Exterior Upper Deck Lighting | 3 | 1 | 120 | 0.1 | 0.1 | 0.5 | 0.1 | 0.1 | 0.5 | |||||||||||
| Bowthruster Battery Charger | 1 | 1 | 120 | 0.5 | 0.0 | 0.0 | 0.5 | 0.0 | 0.0 | |||||||||||
| Dive Room Receptacles | 4 | 1 | 120 | 0.1 | 0.1 | 0.2 | 0.1 | 0.1 | 0.3 | |||||||||||
| Dive Equip Rm Heater | 1 | 1 | 120 | 0.0 | 0.0 | 0.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Lazarette Heater | 1 | 1 | 120 | 0.0 | 0.0 | 0.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Aft Deck Receptacles #1 | 2 | 1 | 120 | 0.1 | 0.1 | 0.2 | 0.1 | 0.1 | 0.3 | |||||||||||
| Aft Deck Receptacles #2 | 2 | 1 | 120 | 0.1 | 0.1 | 0.2 | 0.1 | 0.1 | 0.3 | |||||||||||
| Main Engine / Gen Battery Charger | 1 | 1 | 120 | 0.5 | 0.0 | 0.0 | 0.5 | 0.0 | 0.0 | |||||||||||
| House Battery Charger | 1 | 1 | 120 | 0.5 | 0.0 | 0.0 | 0.5 | 0.0 | 0.0 | |||||||||||
| Galley Heater | 1 | 1 | 120 | 0.0 | 0.0 | 0.0 | 1.0 | 1.0 | 1.0 | |||||||||||
| Monkey Heater | 1 | 1 | 120 | 0.0 | 0.0 | 0.5 | 0.0 | 0.0 | 1.0 | |||||||||||
| Refrigerator | 1 | 1 | 120 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | |||||||||||
| Fire Alarm System | 1 | 1 | 120 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | |||||||||||
| Coffee Maker | 1 | 1 | 120 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | |||||||||||
| Microwave Oven | 1 | 1 | 120 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | |||||||||||
| Main Cabin Receptacles | 7 | 1 | 120 | 0.1 | 0.5 | 0.5 | 0.1 | 0.5 | 0.5 | |||||||||||
| Pilothouse Receptacles | 2 | 1 | 120 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | |||||||||||
| Pilothouse Lighting | 1 | 1 | 120 | 0.3 | 1.0 | 1.0 | 0.3 | 1.0 | 1.0 | |||||||||||
| TOTAL 120 and 240 VAC LOADS (kW) | ||||||||||||||||||||
| Available Power (1 Generator) | ||||||||||||||||||||
| Load as a Percentage of Available Power (%) |
| Summer Conditions | Winter Conditions | |||||||||||||||||||
| Shore | Transit | Dive Operations | Shore | Transit | Dive Operations | |||||||||||||||
| Description | Supplier | OEM P/N | Qty | Phase | Volts | Amps | PF | Attached Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) | Usage Factor | Adjusted Load (kW) |
| 480 VAC Loads | ||||||||||||||||||||
| DER 480VAC Receptacle | 1 | 3 | 480 | 0.1 | 0.0 | 0.1 | 0.1 | 0.0 | 0.1 | |||||||||||
| Main Cabin 480VAC Receptacle | 1 | 3 | 480 | 0.1 | 0.0 | 0.1 | 0.1 | 0.0 | 0.1 | |||||||||||
| Dive Compressor | 1 | 3 | 480 | 0.9 | 0.0 | 0.9 | 0.9 | 0.0 | 0.9 | |||||||||||
| Seawater Pump / Cofferdam Eductor | 1 | 3 | 480 | 0.0 | 0.0 | 0.3 | 0.0 | 0.0 | 0.3 | |||||||||||
| Hydraulic Power Unit, 15HP | 1 | 3 | 480 | 0.0 | 0.0 | 0.3 | 0.0 | 0.0 | 0.3 | |||||||||||
| Aft Work Deck Receptacle 480VAC | 1 | 3 | 480 | 0.1 | 0.0 | 0.1 | 0.1 | 0.0 | 0.1 | |||||||||||
| TOTAL 480 VAC LOADS (kW) | ||||||||||||||||||||
| Available Power (1 Generator) | ||||||||||||||||||||
| Load as a Percentage of Available Power (%) |
| Total Loads (480VAC & 240/120VAC) (kW) |
| Available Power w/ Paralleled Generators, XXkW each (kW) |
| Load as Percentage of Available Power w/2 generators (%) |