This federal contract opportunity solicitation seeks proposals for repairs and renovations to Building 1648 at Fort Worth Air Force Reserve Command in support of the incoming F-35 flying mission. The project will be conducted in phases to ensure continuity of the existing F-16 mission. Renovations include floor plan changes, additional fixtures, separate male/female locker rooms, installation of a fire sprinkler system and FA/MNS in the original building, ductwork modifications, and refinishing degraded spaces and exterior doors/windows/gutters/downspouts/fascia. The single award, firm fixed price contract is between $1 million and $5 million. The low price technically acceptable source selection method will be used. The solicitation is anticipated for release on March 15th with a site visit on March 30th and RFI due date of April 7th. Proposals will be due April 18th with an estimated construction schedule to be determined at award. Funds are not presently available and the solicitation will be issued at SAM.gov. Prospective contractors must register in SAM to receive solicitation changes and be eligible for award.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ROOM NAME

FLOOR

FINISH

BASE

NORTH FINISH

WALL CEILING

MATERIAL HEIGHT

MILLWORK

COUNTER CABINETSEAST FINISH SOUTH FINISH WEST FINISH

WALL WALL WALLROOM FINISH SCHEDULE

REMARKS

FINISH

FINISH SCHEDULE

CORRIDOR

TRAINING

MECHANICAL

STORAGE A

ARMS VAULT

MULTI PURPOSE

AME MAINTENANCE SHOP

FEMALE

HUDDLE

MALE

STORAGE

JANITOR

ADMINISTRATION

CORRIDOR

OFFICE

OFFICE

TRAINING

FEMALE

MALE

GUN MAINT. SHOP VAULT

STORAGE B

STORAGE C

MECHANICAL

TELECOM

CORRIDOR

LVT-1

CPT-1

ETR

ETR

ETR

LVT-1

ETR

CTF-1

CPT-1

CTF-1

CONC-1

CONC-1

LVT-1

LVT-1

CPT-1

CPT-1

CPT-1

LVT-1

LVT-1

ETR

ETR

ETR

ETR

SDT-1

LVT-1

PT-1 PT-1 PT-1 PT-1

PT-1 PT-1 PT-1

PT-1 PT-1 PT-1

PT-1 PT-1 PT-1 PT-1

PT-1 PT-1 PT-1 PT-1

PT-1 PT-1

RWB-1

RWB-1

RWB-1

RWB-1

CTB-1

RWB-1

CTB-1

PT-1 PT-1 PT-1

RWB-1

ROOM #

PT-1

CT-1 / PT-1

PT-1

CEILING

ACT-1 MANUF.: ARMSTRONG

PATTERN: ULTIMA LAY-IN AND

TEGULAR

COLOR: WHITE

SIZE: 24"X24"X15/16"

GENERAL NOTES

1. REFER TO SHEET I-101 FOR FLOOR FINISH

LOCATIONS.

FLOOR

FINISH LEGEND

WALL

CONC-1 MANUF: --

PATTERN: SEALED CONCRETE

PT -1 MANUF: SHERWIN WILLIAMS

COLOR: SW 7029 AGREEABLE GREY

FINISH: SATIN - INT.

1 COAT PRIMER

2 COATS PAINT

LOCATION: WALLS

PT -2 MANUF: SHERWIN WILLIAMS

COLOR: SW 7007 CEILING WHITE

FINISH: FLAT

1 COAT PRIMER

2 COATS PAINT

LOCATION: GYPSUM BOARD CEILINGS

PT -3 MANUF: SHERWIN WILLIAMS

COLOR: SW7019 GAUNTLET GRAY

FINISH: SATIN - EXT

1 COAT PRIMER, 2 COATS PAINT

LOCATION: EXTERIOR DOORS & FRAMES

CT-1 MANUF: CROSSVILLE

PATTERN: 12" X 24" X

COLOR: CALDERA AV292

TYPE: BASALT PORCELAIN STONE

HEIGHT: 42" WAINSCOT

METAL MANUF: SCHLUTER

EDGING PROFILE: QUADEC

MATERIAL: ZINC

COLOR: CLASSIC GREY

BASE

RWB-1 MANUF.: JOHNSONITE

COLOR: 24 MOON ROCK

HEIGHT: 4"

PT-1

PT-1

PT-1

RWB-1

RWB-1

ETR ETR

10'-0"

PT-1 PT-1 PT-1 PT-1

PT-1 PT-1 PT-1

PT-1 PT-1 PT-1

PT-1 PT-1 PT-1 PT-1

PT-1 PT-1 PT-1 PT-1

PT-1

PT-1 PT-1

PT-1 PT-1 PT-1

RWB-1

RWB-1

RWB-1

RWB-1

RWB-1

RWB-1

RWB-1

PT-1 PT-1 PT-1

RWB-1

PT-1

PT-1PT-1

PT-1

PT-1

PT-1

PT-1

PT-1

PT-1

RWB-1

RWB-1

PT-1 PT-1 PT-1 PT-1

PT-1

PT-1 PT-1

PT-1 PT-1 PT-1

RWB-1

RWB-1

RWB-1

RWB-1

PT-1PT-1

PT-1

PT-1

PT-1

PT-1

ETR

ETR

ETR

GYP, PT-2

12'-0"

---PT-1 PT-1 PT-1RWB-1 PT-1

103A

112A

ACT-1 12'-0"

PT-1 PT-1 PT-1 PT-1

PT-1 PT-1 PT-1 PT-1

ACT-1 10'-0"

ACT-1

OPEN

ACT-1 11'-0"

ACT-2 10'-0"

ACT-1 10'-0"

ACT-2 10'-0"

ACT-1 10'-0"

GYP, PT-2

ACT-1 10'-0"

ACT-1 10'-0"

ACT-1 10'-0"

ACT-1 10'-0"

ACT-1

ACT-1

10'-0"

10'-0"

HPDL-1

SS-1

SS-1

SS-1

SS-1

HPDL-1

HPDL-1

HPDL-1

HPDL-1

CT-1 / PT-1 CT-1 / PT-1

CT-1 / PT-1 CT-1 / PT-1

CT-1 / PT-1 CT-1 / PT-1

CT-1 / PT-1

METAL EDGING AT TOP OF WAINSCOT

ACT-2 MANUF.: ARMSTRONG

PATTERN: WATER-RESISTANT

ULTIMA HEALTH ZONE

HIGH NRC

COLOR: WHITE

SIZE: 2'X2'X15/16"

CPT-1 MANUF: MOHAWK

PATTERN: 24 X 24 ARMSTRONG

COLOR: 859 FRANKLIN

TYPE: SIDE STRIPS TILE GT 149

LVT-1 MANUF: MOHAWK

PATTERN: MATUTO PLUS STONE

COLOR: AGREEABLE GREY STONE

TYPE: 12"W X 24"L PLANKS

SDT-1 MANUF: ARMSTRONG

PATTERN: 12" X 12"

COLOR: 51950 MARBLE BEIGE

TYPE: EXCELON

CTF-1 MANUF: CROSSVILLE

PATTERN: 12" X 12" X

COLOR: CALDERA AV292

TYPE: BASALT PORCELAIN STONE

PLASTIC LAMINATE

HPDL-1 MANUF: FORMICA

COLOR: 5880-58 EARTHEN WARP

SOLID SURFACE

SS-1 MANUF.: WILSONART

PATTERN: JOVIAN 9211 CM

MISC.

GT-1 MANUF.: MAPEI

COLOR: 11 SAHARA BEIGE

CTB-1 MANUF.: CROSSVILLE

COLOR: CALDERA AV292 TRIM

TYPE: BASALT PORCELAIN STONE

HEIGHT: COVE BASE 6" X 12"

HDPL-1 MANUF.: WILSONART

COLOR: JOVIAN 9211 CM

10'-0"

OPEN

10'-0"

10'-0"

VCG-1 MANUF.: BABCOCK DAVIS

PRODUCT: BCVGS3S-P PVC FREE

COLOR: PEARL

ETR

ETR

ACT-1

ACT ACOUSTICAL CEILING TILE

FINISH ABBREVIATIONS:

RWB RUBBER WALL BASE

PT

PAINT

ETR EXISTING TO REMAIN

CONC SEALED CONCRETE

CPT CARPET

CT CERAMIC TILE

HPDL HIGH PRESSURE DECORATIVE LAMINATE

SS SOLID SURFACE

SDT STATIC DISSAPATIVE TILE

CTF CERAMIC FLOOR TILE

VCT VINYL COMPOSITION TILE

GT GROUT

TP TOILET PARTITION

VCG VINYL CORNER GUARD

LVT LUXURY VINYL TILE

ACT-1

ACT-1

TOILET PARTITIONS ( HPDE)

TP-1 MANUF.: POLYLIFE

PATTERN: 120 SAND SPECKLE

CORNER GUARDS

VCG-1 MANUF.: BABCOCK DAVIS

PATTERN: BCGVS3S

HEIGHT: 48"

NOTE: ALL OUT SIDE CORNERS ARE TO

RECEIVE CORNER GUARDS

OPEN

OPEN

OPEN

10'-0"

10'-0"

GYP GYPSUM CEILING BOARD

MANUF.: CHICAGO METALLIC

COLOR: CEILING WHITE

SIZE: 5/8"

METAL EDGING AT TOP OF WAINSCOT

METAL EDGING AT TOP OF WAINSCOT

SEE SCHEDULE

TYPE 2TYPE 1

SEE SCHEDULE

TYPE 3

S E

E

S

C H

E D

U L

E

S E

E

S

C H

E D

U L

E

SEE SCHEDULE

TYPE 4

S E

E

S

C H

E D

U L

E

RATED SAFETY

GLAZING

RATED SAFETY

GLAZING

SEE SCHEDULE

S E

E

S

C H

E D

U L

E

ROOM NAME TYPE

ROOM FINISH SCHEDULE

REMARKS

DOOR SCHEDULE

DOOR #

DOOR FRAME DETAILS

HARDWARE

FUNCTION

FIRE

RATING

TRANSITION

DETAIL

MATERIAL SIZE TYPE MATERIAL HEAD JAMB

100A

CORRIDOR

CORRIDOR

101 TRAINING

102 MECHANICAL

103 STORAGE A

103A ARMS VAULT

103B STORAGE A

103C STORAGE A

105 AME MAINTENANCE SHOP

105A AME MAINTENANCE SHOP

106 FEMALE

107 HUDDLE

108 MALE

109 STORAGE

110 JAN

123 HALLWAY

123A HALLWAY

123B HALLWAY

112 ADMIN

112A CORRIDOR

113 OFFICE

114 OFFICE

115 TRAINING

115A TRAINING

116 FEMALE

117 MALE

118A

GUN MAINT. SHOP VAULT

GUN MAINT. SHOP VAULT

119 STORAGE B

120 STORAGE C

1 D HM

EXISTING EXISTING

3'-0" X 7'-0"

A

A

3'-0" X 7'-0"

3'-0" X 7'-0"

3'-0" X 7'-0"

3'-0" X 7'-0"

116A

117A MALE

FEMALE 1

3'-0" X 7'-0"

3'-0" X 7'-0"

A

A

HM

HM

HM

HM

1 HM 4'-0" X 7'-0" STLC

122 TELCOM

MECH

1 3'-0" X 7'-0" A HM

EXISTING EXISTING EXISTING

A

A

HM

HM

1 3'-0" X 7'-0" C

1 3'-0" X 7'-0" C HM

HM

PR. 3'-0" X 7'-0"

B HM

1 SCWD 3'-0" X 7'-0" D HM

1 3'-0" X 7'-0" D HM

1 3'-0" X 7'-0" A HM

EXISTING

EXISTING

3 3'-0" X 7'-0" A HM

4 4

4 4

4 4

3 3

3 3

EXISTING

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

3 3

3 3

P/P W/ DB

PRIVACY

P/P W/ DB

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

OFFICE

OFFICE

OFFICE

P/P W/ DB

P/P

P/P W/ DB

P/P

COMBO LOCK

EXISTING

STOREROOM

REMARKS:

1. DOOR IS REQUIRED TO MEET THE REQUIREMENTS OF A CLASS 5A VAULT DOOR AND

FRAME AND FF-L-2937 MECHANICAL COMBINATION LOCK

2. REFINISH AND PROVIDE NEW WATHERSTRIPPING

3. REFNISH

4. CASED OPENING

5. OVERHEAD COILING DOOR/PROVIDE PAD-LOCKABLE LOCKING BARS

6. REPLACE EXISTING PANIC DEVICE AND HINGES W/NEW DEADBOLT PANIC DEVICE

TAMPERPROOF HINGES. DOOR SHALL HAVE NO EXTERIOR LATCHSET

7. PROVIDE PAD-LOCKABLE LOCKING BARS

8. REFINISH EXISTING DOOR FRAME

118B STORAGE B 11'-0" X 11'-4"

T2

T3

T1

T3

T1

T2

T2

T2

112B

C C

7'-8" X 7'-4" CLEAR OPENING

HM

CORRIDOR

STL

4 STL

112C C

C

HM

CORRIDOR

A

B

EXISTING

EXISTING EXISTING EXISTING EXISTING

EXISTING EXISTING EXISTING EXISTING EXISTING

EXISTING EXISTING EXISTING EXISTING EXISTING

EXISTING EXISTING EXISTING EXISTING EXISTING

EXISTING EXISTING EXISTING EXISTING EXISTING

EXISTING EXISTING EXISTING EXISTING EXISTING

EXISTING EXISTING EXISTING EXISTING EXISTING

EXISTING EXISTING EXISTING EXISTING EXISTING

EXISTING EXISTING EXISTING EXISTING EXISTING

EXISTING EXISTING EXISTING EXISTING EXISTING

EXISTING EXISTING EXISTING EXISTING EXISTING

4 -

4 -

2,6

5,7

EXISTING EXISTING EXISTING

EXISTING EXISTING EXISTING EXISTING EXISTING

EXISTING

EXISTING EXISTING EXISTING EXISTING EXISTING

EXISTING EXISTING EXISTING EXISTING EXISTING

EXISTING EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING EXISTING

EXISTING

EXISTING EXISTING

EXISTING EXISTING

EXISTING EXISTING

EXISTING EXISTING

EXISTING EXISTING

EXISTING EXISTING

EXISTING EXISTING

4 4

EXISTING EXISTING

EXISTING EXISTING

EXISTING EXISTING

EXISTING EXISTING

EXISTING EXISTING

EXISTING EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING EXISTING

EXISTING

EXISTING

EXISTING

7'-8" X 7'-4" CLEAR OPENING

STL STL STL

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

SCWD

3 3'-0" X 7'-0"

3 SCWD 3'-0" X 7'-0"

SCWD

SCWD

SCWD

SCWD

1 SCWD 3'-0" X 7'-0"

2" 2"

TYPE A

S E

E

D

O O

R

S

I Z

E

2" 2"

TYPE B

S E

E

D

O O

R

S

I Z

E

SEE DOOR SIZE SEE DOOR SIZE

2"

2"

TYPE C

S E

E

D

O O

R

S

I Z

E

SEE DOOR SIZE

2" 2"

TYPE D

S E

E

D

O O

R

S

I Z

E

SEE DOOR SIZE

TEMP

TEMP

CONT.SEALANT EA. SIDE

16 GA H.M. FRAME

DOOR PANEL

CONT.SEALANT

EA. SIDE

16 GA. HM FRAME

STL STUD

ANCHOR, 3 PER JAMB

DOOR

7 8

5 8

SEALANT EACH SIDE

HM DOOR FRAME

2"

EXIST. WALL

SEALANT EACH SIDE

HM DOOR FRAME

EPOXY MASONRY JAMB

ANCHOR, 3 PER JAMB,

SPOT GROUT AND

INSTALL INSULATION IN

FRAME.

EXIST. WALL

VCT OR LVT

METAL TRANSITION STRIP

SCHLUTER RENO-U OR SIM.

CERAMIC TILE OVER

THINSET

DETAIL

TRANSITION BETWEEN CERAMIC TILE

AND VINYL COMPOSITION TILE

DOOR℄

VCT OR LVT

DETAIL

TRANSITION BETWEEN VINYL

COMPOSITION TILE AND CONCRETE

DOOR℄

RUBBER TRANSITION STRIP

JOHNSONITE REDUCER OR

SIM.

EXISTING FLOOR

SLAB

EXISTING FLOOR

SLAB

T2T1

VCT OR LVT

DETAIL

TRANSITION BETWEEN VINYL

COMPOSITION TILE AND CARPET TILE

DOOR℄

RUBBER TRANSITION STRIP

JOHNSONITE ADAPTOR OR

SIM.

EXISTING FLOOR

SLAB

T3

EXIST. WALL

SEALANT

EACH SIDE

2"

EXIST. WALL

SEALANT EACH SIDE

HM FRAME

EPOXY MASONRY JAMB

ANCHOR, 3 PER JAMB,

SPOT GROUT AND

INSTALL INSULATION IN

FRAME.

NEW STEEL

LINTEL

GROUT FILLED

HM DOOR FRAME

NOTCHED CMU

FACE SHELL SOAP

SEALANT EACH SIDE

GROUT FILLED

HM DOOR FRAME

NEW STEEL

LINTEL

FACE SOAP W/ TWO-PIECE

FLEXIBLE ANCHOR. NOTCH

SOAP TO FIT BEAM

C O

N T

R A

C T

N

O

F I L E

A M

E

D W

N

B

Y

C K

D

B

Y

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

N T

P

D

A T

F I

U M

B E

R

S I Z

E

S U

B M

I T

T E

D

B

Y

P L O

T

S

C A

L E

I S

S U

E

D

A T

E

D A

T E

M A

R K

D E

S C

R I P

T I O

N

D E

L I V

E R

Y

O

R D

E R

SHEET

IDENTIFICATION

D A

T E

A P

P R

U S

A

R

R

C

S

E R

V E

N A

S

J R

B

F o r t

W o r t h

T

X

C O

M M

A N

D

K

E W

O O

D

P

K Y

S

A L

P H

A R

E T

T A

G

A

W o o d

Z

A P

A T

A

J V

CORRECTED FINAL - ISSUE FOR CONSTRUCTION

F A

D

F A

F

A U

G U

S T

A N

S I

D

S

T

E D

M

S

I L V

I

M A

Y

R

D

W G

R E

N O

V A

W

A

P O

N S

R E

L E

A S

E

S

Y S

T E

M S

M A

I N

T E

N A

N C

E

F

A C

I L

I T

Y

B

C O

R R

E C

T E

D

F

I N

A L

R

E V

I S

I O

N S

J U

C O

R R

E C

T E

D

F

I N

A L

R

E V

I S

I O

N S

J U

Y

A-601

D O

D

N

I S

H

I N

F O

R M

A T

I O

N

Scale: 3/8" = 1'-0"

DOOR TYPES

Scale: 3/8" = 1'-0"

FRAME TYPES

Scale: 1 1/2" = 1'-0"

HEAD/JAMB (STANDARD FRAME)

Scale: 1 1/2" = 1'-0"

HEAD/JAMB

Scale: 1 1/2" = 1'-0"

FLOOR FINISH TRANSITION DETAILS

Scale: 1 1/2" = 1'-0"

CASED OPENING

A B C

M

S

I L V

I

D

P

R A

T T

R

A

S H

E

GRAPHIC SCALE

1 1/2" = 1'-0"

0 6" 1'-6"1'

GRAPHIC SCALE

3/8" = 1'-0"

0 2' 4' 6'

BOLD ITALICS

INDICATE

REVISIONS MADE

TO THE SCHEDULE

07/19/21

RENOVATE WEAPONS/RELEASE SYSTEM FACILITY, B1648 FORT WORTH

AFRC NAS JRB TEXAS

SECTION TABLE OF CONTENTS

DIVISION 08 - OPENINGS

SECTION 08 71 00

DOOR HARDWARE

02/16

PART 1 GENERAL

1.1 REFERENCES

1.2 SUBMITTALS

1.3 SHOP DRAWINGS

1.4 PRODUCT DATA

1.5 HARDWARE SCHEDULE

1.6 KEY BITTING CHART REQUIREMENTS

1.6.1 Requirements

1.7 QUALITY ASSURANCE

1.7.1 Hardware Manufacturers and Modifications

1.7.2 Key Shop Drawings Coordination Meeting

1.8 DELIVERY, STORAGE, AND HANDLING

PART 2 PRODUCTS

2.1 TEMPLATE HARDWARE

2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS

2.3 HARDWARE ITEMS

2.3.1 Hinges

2.3.2 Locks and Latches

2.3.2.1 Mortise Locks and Latches

2.3.2.2 Bored Locks and Latches

2.3.2.3 Auxiliary Locks

2.3.2.4 Combination Locks

2.3.3 Exit Devices

2.3.4 Exit Locks With Alarm

2.3.5 Cylinders and Cores

2.3.6 Push Button Mechanisms

2.3.7 Electrified Hardware

2.3.7.1 Electrified Mortise Locks

2.3.7.1.1 Power Transfer Hinges

2.3.7.2 Electromagnetic Locks

2.3.7.2.1 Armature

2.3.7.2.2 Tamper Resistance

2.3.7.2.3 Mounting Method

2.3.7.3 Delayed Egress Locking System

2.3.8 Keying System

2.3.9 Lock Trim

2.3.9.1 Knobs and Roses

2.3.9.2 Lever Handles

2.3.9.3 Texture

2.3.10 Keys

2.3.11 Door Bolts

2.3.12 Closers

2.3.12.1 Identification Marking

SECTION 08 71 00 Page 1

2.3.13 Overhead Holders

2.3.14 Door Protection Plates

2.3.14.1 Sizes of Kick Plates

2.3.15 Door Stops and Silencers

2.3.16 Padlocks

2.3.17 Thresholds

2.3.18 Weatherstripping Gasketing

2.3.18.1 Extruded Aluminum Retainers

2.3.18.2 Interlocking Type

2.3.18.3 Spring Tension Type

2.3.19 Rain Drips

2.3.19.1 Door Rain Drips

2.3.19.2 Overhead Rain Drips

2.3.20 Auxiliary Hardware (Other than locks)

2.3.21 Sliding and Folding Door Hardware

2.3.22 Special Tools

2.4 FASTENERS

2.5 FINISHES

PART 3 EXECUTION

3.1 INSTALLATION

3.1.1 Weatherstripping Installation

3.1.1.1 Stop Applied Weatherstripping

3.1.1.2 Interlocking Type Weatherstripping

3.1.1.3 Spring Tension Type Weatherstripping

3.1.2 Threshold Installation

3.2 FIRE DOORS AND EXIT DOORS

3.3 HARDWARE LOCATIONS

3.4 FIELD QUALITY CONTROL

3.5 HARDWARE SETS

-- End of Section Table of Contents --

SECTION 08 71 00 Page 2

SECTION 08 71 00

DOOR HARDWARE

02/16

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM E283 (2019) Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen

ASTM F883 (2013) Padlocks

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.1 (2016) Butts and Hinges

ANSI/BHMA A156.2 (2017) Bored and Preassembled Locks and Latches

ANSI/BHMA A156.3 (2014) Exit Devices

ANSI/BHMA A156.4 (2013) Door Controls - Closers

ANSI/BHMA A156.5 (2014) Cylinder and Input Devices for Locks

ANSI/BHMA A156.6 (2015) Architectural Door Trim

ANSI/BHMA A156.7 (2016) Template Hinge Dimensions

ANSI/BHMA A156.8 (2015) Door Controls - Overhead Stops and Holders

ANSI/BHMA A156.13 (2017) Mortise Locks & Latches Series 1000

ANSI/BHMA A156.14 (2013) Sliding and Folding Door Hardware

ANSI/BHMA A156.16 (2018) Auxiliary Hardware

ANSI/BHMA A156.18 (2016) Materials and Finishes

ANSI/BHMA A156.21 (2019) Thresholds

ANSI/BHMA A156.22 (2017) Door Gasketing and Edge Seal Systems

ANSI/BHMA A156.23 (2010) Electromagnetic Locks

SECTION 08 71 00 Page 3

ANSI/BHMA A156.24 (2012) Delayed Egress Locking Systems

ANSI/BHMA A156.25 (2013) Electrified Locking Devices

ANSI/BHMA A156.29 (2012) Exit Locks, Exit Alarms, Alarms for Exit Devices

ANSI/BHMA A156.36 (2010) Auxiliary Locks

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 70 (2020; ERTA 20-1 2020; ERTA 20-2 2020; TIA

20-1; TIA 20-2; TIA 20-3; TIA 20-4)

National Electrical Code

NFPA 72 (2019; TIA 19-1; ERTA 1 2019) National Fire Alarm and Signaling Code

NFPA 80 (2019) Standard for Fire Doors and Other Opening Protectives

NFPA 101 (2018; ERTA 18-1; ERTA 18-2; ERTA 18-3;

ERTA 18-4; TIA 18-1; TIA 18-2; TIA 18-3;

TIA 18-4) Life Safety Code

NFPA 252 (2017) Standard Methods of Fire Tests of Door Assemblies

STEEL DOOR INSTITUTE (SDI/DOOR)

SDI/DOOR A250.8 (2017) Specifications for Standard Steel Doors and Frames

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines

UNDERWRITERS LABORATORIES (UL)

UL Bld Mat Dir (updated continuously online) Building Materials Directory

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Manufacturer's Detail Drawings; G

Verification of Existing Conditions; G

Hardware Schedule; G

SECTION 08 71 00 Page 4

Keying System; G

SD-03 Product Data

Hardware Items; G

SD-08 Manufacturer's Instructions

Installation

SD-10 Operation and Maintenance Data

Hardware Schedule Items, Data Package 1; G

SD-11 Closeout Submittals

Key Bitting

1.3 SHOP DRAWINGS

Submit manufacturer's detail drawings indicating all hardware assembly components and interface with adjacent construction. Base shop drawings on verified field measurements and include verification of existing conditions.

1.4 PRODUCT DATA

Indicate fire-ratings at applicable components. Provide documentation of ABA/ADA accessibility compliance of applicable components, as required by 36 CFR 1191 Appendix D - Technical.

1.5 HARDWARE SCHEDULE

Prepare and submit hardware schedule in the following form:

Hardware Item

Quantity Size Reference Publi-cation Type No.

Finish Mfr Name and Catalog No.

Key Control Symbols

UL

Mark (If fire-rated and listed)

BHMA

Finish Desig-nation

1.6 KEY BITTING CHART REQUIREMENTS

1.6.1 Requirements

Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:

a. Complete listing of all keys (e.g. AA1 and AA2).

b. Complete listing of all key cuts (AA1-123456, AA2-123458).

c. Tabulation showing which key fits which door.

SECTION 08 71 00 Page 5

d. Copy of floor plan showing doors and door numbers.

e. Listing of 20 percent more key cuts than are presently required in each master system.

1.7 QUALITY ASSURANCE

1.7.1 Hardware Manufacturers and Modifications

Provide, as far as feasible, locks, hinges, and closers of one lock, hinge, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.

1.7.2 Key Shop Drawings Coordination Meeting

Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware Subcontractor, using Activity and Base Locksmith must meet to discuss and coordinate key requirements for the facility.

1.8 DELIVERY, STORAGE, AND HANDLING

Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown on hardware schedule.

Deliver permanent keys and removable cores to the Contracting Officer, either directly or by certified mail. Deliver construction master keys with the locks.

PART 2 PRODUCTS

2.1 TEMPLATE HARDWARE

Hardware applied to metal or to prefinished doors must be manufactured using a template. Provide templates to door and frame manufacturers in accordance with ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.

2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS

Provide all hardware necessary to meet the requirements of NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, NFPA 252 for fire tests of door assemblies, ABA/ADA accessibility requirements, and all other requirements indicated, even if such hardware is not specifically mentioned in paragraph HARDWARE SCHEDULE. Provide Underwriters Laboratories, Inc. labels for such hardware in accordance with UL Bld Mat Dir or equivalent labels in accordance with another testing laboratory approved in writing by the Contracting Officer.

2.3 HARDWARE ITEMS

Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the identifying mark is visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover. Coordinate electrified door hardware components with corresponding components specified in Division 28 ELECTRONIC SECURITY SYSTEMS (ESS).

SECTION 08 71 00 Page 6

2.3.1 Hinges

Provide in accordance with ANSI/BHMA A156.1 . Provide hinges that are 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for interior doors and reverse-bevel exterior doors so that pins are non-removable when door is closed. Other anti-friction bearing hinges may be provided in lieu of ball bearing hinges.

2.3.2 Locks and Latches

a. At exterior locations provide locksets of full stainless steel type 302 or 304 construction including fronts, strike, escutcheons, knobs, bolts and all interior working parts. Marine Grade I, fully non-ferrous.

b. In non-air-conditioned interior environments or humid interior environments, provide interior locksets on the same Marine Grade I, fully non-ferrous as exterior locksets.

2.3.2.1 Mortise Locks and Latches

Provide in accordance with ANSI/BHMA A156.13 , Series 1000, Operational Grade 1, Security Grade 2. Provide mortise locks with escutcheons not less than 7 by 2-1/4 inch with a bushing at least 1/4 inch long. Cut escutcheons to fit cylinders and provide trim items with straight, beveled, or smoothly rounded sides, corners, and edges. Provide knobs and roses of mortise locks with screwless shanks and no exposed screws.

2.3.2.2 Bored Locks and Latches

Provide in accordance with ANSI/BHMA A156.2 , Series 4000, Grade 1.

2.3.2.3 Auxiliary Locks

Provide in accordance with ANSI/BHMA A156.36 , Grade 1.

2.3.2.4 Combination Locks

Heavy-duty, mechanical combination lockset with five push buttons, standard sized knobs, 3/4 inch deadlocking latch, 2-3/4 inch backset.

Locks to operate by pressing two or more of the buttons in unison or individually in the proper sequence. Inside knob operates the latch.

Provide a keyed cylinder on the interior to permit setting the combination.

2.3.3 Exit Devices

Provide in accordance with ANSI/BHMA A156.3 , Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices. Provide touch bars in lieu of conventional crossbars and arms. Provide escutcheons not less than 7 by 2-1/4 inch.

Use stainless steel or bronze base metal with plated finishes. Also include stainless steel fasteners and screws.

2.3.4 Exit Locks With Alarm

Provide in accordance with ANSI/BHMA A156.3 and ANSI/BHMA A156.29 , Type E0431 (with full width horizontal actuating bar) for single doors; Type

SECTION 08 71 00 Page 7

E0431 (with actuating bar) or E0471 (with actuating bar and top and bottom bolts, both leaves active) for pairs of doors, unless otherwise specified.

Provide door alarms integrated with the fire alarm system in accordance with NFPA 72 .

2.3.5 Cylinders and Cores

Provide cylinders and cores for new locks, including locks provided under other sections of this specification. Provide cylinders and cores with six pin tumblers. Provide cylinders from the products of one manufacturer, and provide cores from the products of one manufacturer. Rim cylinders, mortise cylinders, and knobs of bored locksets have interchangeable cores which are removable by special control keys. Stamp each interchangeable core with a key control symbol in a concealed place on the core.

Provide cylinders for new locks, including locks provided under other sections of this specification. Provide fully compatible cylinders of Grade 1 products from products of one manufacturer with interchangeable cores that are removable by a special control key. Factory set the cores with six pin tumblers using the A4 system and F keyway. Submit a core code sheet with the cores. Provide master keyed cores in one system for this project. Provide construction interchangeable cores.

For medical projects, key pharmacy door locks separately from building master key system.

2.3.6 Push Button Mechanisms

Provide in accordance with ANSI/BHMA A156.5 , Grade 1.

2.3.7 Electrified Hardware

Comply with the requirements of NFPA 70 for wiring of electrified hardware.

2.3.7.1 Electrified Mortise Locks

Provide in accordance with ANSI/BHMA A156.25 , Grade 1. Provide electrified mortise locks that remain secure during power failure.

Provide facility interface devices that use dc power to energize solenoids. Provide solenoids, resisters, and signal switches in accordance with paragraph ELECTRIC STRIKES AND FRAME MOUNTED ACTUATORS.

2.3.7.1.1 Power Transfer Hinges

Provide power transfer hinges with each electrified lock that route power and monitoring signals from the lockset to the door frame. Coordinate power transfer hinges with door frames.

2.3.7.2 Electromagnetic Locks

Provide in accordance with ANSI/BHMA A156.23 , Grade 1. Provide electromagnetic locks that do not contain any moving parts and depend solely upon electromagnetism to secure a portal by generating at least 1200 pounds of holding force. The lock must interface with the local processors without external, internal or functional alteration of the local processor. The electromagnetic lock must incorporate an end of line resistor to facilitate line supervision by the system. Provide metal-oxide resistors (MOVs) to protect controllers from reverse current surges, if not incorporated into the electromagnetic lock or local

SECTION 08 71 00 Page 8 controller.

2.3.7.2.1 Armature

Provide electromagnetic locks with internal circuitry to eliminate residual magnetism and inductive kickback. Provide atuating armature that operates on 12 or 24 Volts dc and cannot dissipate more than 12 Watts.

Holding current must be less than 500 milliamperes. Actuating armature must take less than 300 milliseconds to change the status of the lock from fully secure to fully open or fully open to fully secure.

2.3.7.2.2 Tamper Resistance

Provide lock mechanism encased in hardened guard barriers to deter forced entry.

2.3.7.2.3 Mounting Method

Provide electromagnetic lock suitable for use with single and double door with mortise or rim type hardware and compatible with right or left hand mounting.

2.3.7.3 Delayed Egress Locking System

Provide in accordance with ANSI/BHMA A156.24 , Grade 1.

2.3.8 Keying System

Provide a grand master keying system

The Government will provide permanent cylinders with cores and keys for mortise locksets, auxiliary locks, and exit devices.

2.3.9 Lock Trim

Provide cast, forged, or heavy wrought construction and commercial plain design for lock trim.

2.3.9.1 Knobs and Roses

Provide in accordance with ANSI/BHMA A156.2 and ANSI/BHMA A156.13 for knobs, roses, and escutcheons. For unreinforced knobs, roses, and escutcheons, provide a 0.050 inch thickness. For reinforced knobs, roses, and escutcheons, provide an outer shell thickness of 0.035 inch and a combined total thickness of 0.070 inch, except at knob shanks. Provide knob shanks 0.060 inch thick.

2.3.9.2 Lever Handles

Provide lever handles . Provide in accordance with ANSI/BHMA A156.3 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.

2.3.9.3 Texture

Provide knurled or abrasive coated knobs or lever handles for doors which

SECTION 08 71 00 Page 9 are accessible to blind persons and which lead to dangerous areas.

2.3.10 Keys

Provide one file key, one duplicate key, and one working key for each key change. Provide one additional working key for each lock of each keyed-alike group. Stamp each key with appropriate key control symbol and "U.S. property - do not duplicate." Do not place room number on keys.

Provide seven change keys for each interchangeable core, provide two control keys, six maters keys, and six construction master keys. Provide a quantity of key blanks equal to 20 percent of the total number of change keys. Stamp each key with appropriate key control symbol and "U.S.

property - do not duplicate." Do not place room numbers on keys.

2.3.11 Door Bolts

Provide in accordance with ANSI/BHMA A156.16 . Provide dustproof strikes for bottom bolts, except at doors having metal thresholds. Provide automatic latching flush bolts in accordance with ANSI/BHMA A156.3 , Type 25.

2.3.12 Closers

Provide in accordance with ANSI/BHMA A156.4 , Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full size covers, except at storefront mounting, and other features necessary for the particular application. Size closers in accordance with manufacturer's printed recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.

Use stainless steel inside bracketed or door mounted closers on exterior doors. Non-ferrous closers, such as aluminum or cast bronze, are permissible where door utilization is minimal. On interior doors use closers of 302 or 304 stainless steel or non-ferrous materials. On surface-mounted closers use or apply rust inhibiting finish on all ferrous parts. Also apply this finish on concealed closers.

2.3.12.1 Identification Marking

Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation in locations that will be visible after installation.

2.3.13 Overhead Holders

Provide in accordance with ANSI/BHMA A156.8 .

2.3.14 Door Protection Plates

Provide in accordance with ANSI/BHMA A156.6 .

2.3.14.1 Sizes of Kick Plates

2 inch less than door width for single doors; 1 inch less than door width for pairs of doors. Provide 10 inch kick plates for flush doors .

Provide 4 inch mop plates.

SECTION 08 71 00 Page 10

2.3.15 Door Stops and Silencers

Provide in accordance with ANSI/BHMA A156.16 . Silencers Type L03011.

Provide three silencers for each single door, two for each pair.

2.3.16 Padlocks

Provide in accordance with ASTM F883.

2.3.17 Thresholds

Provide in accordance with ANSI/BHMA A156.21 . Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise.

2.3.18 Weatherstripping Gasketing

Provide in accordance with ANSI/BHMA A156.22 . Provide the type and function designation where specified in paragraph HARDWARE SCHEDULE.

Provide a set to include head and jamb seals, sweep strips, and, for pairs of doors, astragals. Air leakage of weatherstripped doors not to exceed

0.5 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E283. Provide weatherstripping with one of the following:

2.3.18.1 Extruded Aluminum Retainers

Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide bronze anodized aluminum.

2.3.18.2 Interlocking Type

Zinc or bronze not less than 0.018 inch thick.

2.3.18.3 Spring Tension Type

Spring bronze or stainless steel not less than 0.008 inch thick.

2.3.19 Rain Drips

Provide in accordance with ANSI/BHMA A156.22 . Provide extruded aluminum rain drips, not less than 0.08 inch thick, factory primed finish. Provide the manufacturer's full range of color choices to the Contracting Officer for color selection. Set drips in sealant and fasten with stainless steel screws.

2.3.19.1 Door Rain Drips

Approximately 1-1/2 inch high by 5/8 inch projection. Align bottom with bottom edge of door.

2.3.19.2 Overhead Rain Drips

Approximately 1-1/2 inch high by 2-1/2 inch projection. Align bottom with door frame rabbet.

SECTION 08 71 00 Page 11

2.3.20 Auxiliary Hardware (Other than locks)

Provide in accordance with ANSI/BHMA A156.16 , Grade 1.

2.3.21 Sliding and Folding Door Hardware

Provide in accordance with ANSI/BHMA A156.14 , Grade 1. Finishes to match other hardware specified herein.

2.3.22 Special Tools

Provide special tools, such as spanner and socket wrenches and dogging keys, as required to service and adjust hardware items.

2.4 FASTENERS

Provide fasteners of type, quality, size, and quantity appropriate to the specific application. Fastener finish to match hardware. Provide stainless steel or nonferrous metal fasteners in locations exposed to weather. Verify metals in contact with one another are compatible and will avoid galvanic corrosion when exposed to weather.

2.5 FINISHES

Provide in accordance with ANSI/BHMA A156.18 . Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide items not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except aluminum paint finish for surface door closers, and except for steel hinges. Provide hinges for exterior doors in stainless steel with BHMA 630 finish. Furnish exit devices in BHMA 626 finish in lieu of BHMA 630 finish . Match exposed parts of concealed closers to lock and door trim. Match hardware finish for aluminum doors to the doors.

PART 3 EXECUTION

3.1 INSTALLATION

Provide hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.

Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.

3.1.1 Weatherstripping Installation

Provide full contact, weathertight seals that allow operation of doors without binding the weatherstripping.

3.1.1.1 Stop Applied Weatherstripping

Fasten in place with color matched sheet metal screws not more than 9 inch on center after doors and frames have been finish painted.

3.1.1.2 Interlocking Type Weatherstripping

Provide interlocking, self adjusting type on heads and jambs and flexible

SECTION 08 71 00 Page 12 hook type at sills. Nail weatherstripping to door 1 inch on center and to heads and jambs at 4 inch on center.

3.1.1.3 Spring Tension Type Weatherstripping

Provide spring tension type on heads and jambs. Provide bronze nails with bronze. Provide stainless steel nails with stainless steel. Space nails not more than 1-1/2 inch on center.

3.1.2 Threshold Installation

Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws in expansion sleeves. For aluminum thresholds placed on top of concrete surfaces, coat the underside surfaces that are in contact with the concrete with fluid applied waterproofing as a separation measure prior to placement.

3.2 FIRE DOORS AND EXIT DOORS

Provide hardware in accordance with NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, and NFPA 252 for fire tests of door assemblies.

3.3 HARDWARE LOCATIONS

Provide in accordance with SDI/DOOR A250.8 , unless indicated or specified otherwise.

a. Kick and Armor Plates: Push side of single-acting doors. Both sides of double-acting doors.

b. Mop Plates: Bottom flush with bottom of door.

3.4 FIELD QUALITY CONTROL

After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, errors in cutting and fitting and damage to adjoining work.

3.5 HARDWARE SETS

TBD

-- End of Section --

SECTION 08 71 00 Page 13

THIS PAGE INTENTIONALLY LEFT BLANK

SECTION 08 71 00 Page 14

US AIR FORCE RESERVE BUILDING B1648

FORT WORTH, TX

DOOR HARDWARE SCHEDULE 080671 - 1

Hardware Sets

Set: 1.0

Doors: 100, 103, 103C, 105A, 112, 118A, 119, 120, 1238

1 Gasketing (R3E164)*

1 Sweep (R3D534)*

Notes: Reuse balance of existing hardware.

GC to field verify existing conditions for hardware compatibility with door & frame.

Set: 2.0

Doors: 102, 121

2 Sweep (R3D534)*

1 Astragal (R0Y634)*

Set: 3.0

Doors: 115A

1 Continuous Hinge (A31031G)*

1 Exit Device (Type 1, 01)* US32D

1 Sweep (R3D534)*

Set: 4.0

DOOR HARDWARE SCHEDULE 080671 - 2

Doors: 122

3 Hinge (A8112)* US26D

1 Storeroom Lock (F07)* US26D

1 Interchangeable Core (E09241)* 26

1 Door Stop (L02251 / L02121)* US26D

3 Silencer (L03011)*

Set: 5.0

Doors: 113, 114

1 Office Lock (F04)* US26D

1 Interchangeable Core (E09241)* 26

Set: 6.0

Doors: 112A

6 Hinge (A8112)* US26D

2 Flush Bolt (L04251/L04261)* US26D

1 Dust Proof Strike (L04021)* US26D

1 Classroom Lock (F05)* US26D

1 Interchangeable Core (E09241)* 26

1 Surface Closer (C02011 / C02021)* 689

2 Kick Plate (J102)* US32D

2 Door Stop (L02251 / L02121)* US26D

2 Silencer (L03011)*

Set: 7.0

Doors: 109, 123A

1 Classroom Lock (F05)* US26D

1 Interchangeable Core (E09241)* 26

1 Surface Closer (C02011 / C02021)* 689

1 Kick Plate (J102)* US32D

DOOR HARDWARE SCHEDULE 080671 - 3

Set: 8.0

Doors: 110

1 Classroom Lock (F05)* US26D

1 Interchangeable Core (E09241)* 26

1 Surface Closer (C02021-PT4G)* 689

1 Kick Plate (J102)* US32D

Set: 9.0

Doors: 107

1 Privacy Lock (F22)* US26D

1 Surface Closer (C02011 / C02021)* 689

1 Kick Plate (J102)* US32D

Set: 10.0

Doors: 116A, 117A

3 Hinge (A8111)* US26D

1 Push Plate (J301)* US32D

1 Door Pull w/ Plate (J405)* US32D

1 Surface Closer (C02011 / C02021)* 689

1 Kick Plate (J102)* US32D

1 Mop Plate (J103)* US32D

Set: 11.0

Doors: 106, 108, 116, 117

3 Hinge (A8111)* US26D

1 Classroom Deadlock (F17) US26D

DOOR HARDWARE SCHEDULE 080671 - 4

1 Interchangeable Core (E09241)* 26

1 Push Plate (J301)* US32D

1 Door Pull w/ Plate (J405)* US32D

1 Surface Closer (C02011 / C02021)* 689

1 Kick Plate (J102)* US32D

1 Mop Plate (J103)* US32D

Set: 12.0

Doors: 118, 118B

1 Mortise Cylinder (E09251)* US32D

1 Interchangeable Core (E09241)* 26

Notes: Balance of hardware by door supplier.

Set: 13.0

Doors: 100A, 101, 103A, 103B, 105, 123

1 Existing to Remain

Set: 14.0

Doors: 115

1 Exit Device (Type 1, 01)* US32D

RFI 004 Keying Sys
B1648 A-601 Door & Finish Sheet
B1648 08 71 00 with Hardware Sets

File details come from the government source that posted it. Updated .