Attachment 4 Sheep Shade Structures.pdf

PDF 192 KB Posted

Attached to
Protective Canopy Shade System Service (Clay Center, NE)
Solicitation number
1232SA26Q0174
Issued by

About this file

This is an architectural plan sheet for a USDA project, specifically a foundation and structural layout plan for Location 25. The plan is dated January 20, 2022, and is part of a 95% design document prepared by A+F Firm, a firm under contract with Schemmer Associates. The drawing shows structural elements including new support cables, new fabric shades, a new wide flange end column adjacent to a fence line, typical cable braces to screw anchor foundations, and various utility lines (water line, underground telephone line, underground power line). The plan displays dimensional spacing ranging from 6'-0" to 38'-0" across multiple sections and includes a coordinate grid system referencing power poles, woven/wire fence, iron pipe fence, and fence gates.

The foundation plan notes detail structural requirements and construction standards, including requirements for referenced USDA sheets, existing grade matches, screw anchor installations, and undercarriage utility provisions. The plan legend identifies specific infrastructure elements and utilities present at the location. Project identification number 08222.006 is referenced throughout the document. This appears to be a design document for construction or renovation work at a USDA facility, depicting the structural layout and utility coordination necessary for implementation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2 2

2 2 2 2

NEW SUPPORT

CABLES

NEW FABRIC

SHADES

NEW SUPPORT

CABLES

NEW SUPPORT

CABLES

NEW FABRIC

SHADES

NEW FABRIC

SHADES

NEW WIDE FLANGE

END COLUMN

ADJACENT TO

FENCE LINE

TYPICAL CABLE BRACE

TO SCREW ANCHOR

FOUNDATION

S102

S102

TYPICAL CABLE BRACE

TO SCREW ANCHOR

FOUNDATION

TYPICAL CABLE BRACE

TO SCREW ANCHOR

FOUNDATION

TYPICAL CABLE BRACE

TO SCREW ANCHOR

FOUNDATION

TYPICAL CABLE BRACE

TO SCREW ANCHOR

FOUNDATION

TYPICAL CABLE BRACE

TO SCREW ANCHOR

FOUNDATION

TYPICAL CABLE BRACE

TO SCREW ANCHOR

FOUNDATION

TYPICAL CABLE BRACE

TO SCREW ANCHOR

FOUNDATION

TYPICAL CABLE BRACE

TO SCREW ANCHOR

FOUNDATION

TYPICAL CABLE BRACE

TO SCREW ANCHOR

FOUNDATION

6'-0"15'-0" 17'-6" 15'-0" 17'-6" 15'-0" 17'-6" 15'-0" 17'-6" 15'-0" 17'-6" 15'-0" 17'-6" 15'-0" 17'-6" 15'-0" 11'-6"

3'-0"

S102

S102

S102

S102

S102

S102

77 777777

77 77 77 77

NEW WIDE FLANGE

END COLUMN

ADJACENT TO

FENCE LINE

NEW WIDE FLANGE

END COLUMN

ADJACENT TO

FENCE LINE

NEW WIDE FLANGE

END COLUMN

ADJACENT TO

FENCE LINE

NEW WIDE FLANGE

END COLUMN

ADJACENT TO

FENCE LINE

NEW WIDE FLANGE

END COLUMN

ADJACENT TO

FENCE LINE

PROJECT NO.:

NO. DATE BY DESCRIPTION

REVISIONS

L BAETE

S Henk

USDAA-E FIRM

TJS

B DEAN

B DEAN

USDA

REAL PROPERTY

SAFETY & HEALTH

AREA ENGINEER

DRAWN BY

CHECKED BY

DESIGNER

PROJECT MANAGER

EPM

PROJECT NO.

DATE

SHEET

Service Research Agricultural

FACILITIES ENGINEERING SECTION

PLAINS AREA

2150 CENTRE AVE., BLDG D, SUITE 330

FT. COLLINS, CO 89526-8119

U S D A

CA

D

DH

DS

G

PM

C

U s e r s

\m n a c h re in e r\

D o c u m e n ts \0

-A

R C

H R m n a c h re in e r .

rv t

/2

/2

:1

:2

A

M

A103

LOCATION 25

08222.006

TJS

MJN

MJN

1/19/2022

SHADE STRUCTURES

US MEAT ANIMAL RESEARCH CENTER

CLAY CENTER, NEBRASKA

95% DESIGN

08222006- 2- A103 LOCATION 25

SCALE: 1" = 40'-0"

LOCATION 25 - PLAN

FOUNDATION PLAN NOTES:

A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SCHEDULES.

B. REFERENCE SHEET S101 FOR TYPICAL FOUNDATION DETAILS NOT

NECESSARILY INDICATED ON PLAN.

C. MATCH EXISTING GRADE WITH TOP OF FOOTING (T.O.F.) ELEVATION.

D. FOOTINGS ARE REQUIRED BELOW ALL STRUCTURAL COLUMNS.

E. CONTRACTOR FIELD VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER

OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION DOCUMENTS.

F. THE CABLE SYSTEM HAS BEEN DESIGNED BASED ON A SCHEMATIC METAL

CABLE LAYOUT AND PRELIMINARY COLUMN REACTIONS. THE CONTRACTOR

SHALL SUBMIT STAMPED/SIGNED PLANS OF THE CABLE SYSTEM TO THE

ENGINEER OF RECORD. THE ENGINEER OF RECORD SHALL VERIFY THE

ADEQUACY OF THE FOOTINGS AS SHOWN ON THE FOUNDATION PLAN BASED

ON THE ACTUAL COLUMN REACTIONS. IF REQUIRED, THE FOOTING DESIGNS

WILL BE ADJUSTED TO RESIST THE ACTUAL COLUMN REACTIONS.

G. ALL UNDERGROUND UTILITIES WERE PROVIDED FROM DOCUMENTS

SUPPLIED OR MARKED BY THE USDA. SCHEMMER MAKES NO GUARANTEES

ON THE ACCURACY OF THE LOCATIONS OF THESE UTILITIES. THE

CONTRACTOR IS RESPONSIBLE FOR LOCATING BY NECESSARY MEANS ANY

UTILITIES THAT MAY CONFLICT WITH THE WORK.

1 TEMPORARY STAGING AREA, RESTORE TO ORIGINAL CONDITION AFTER

CONSTRUCTION.

2 PROTECT EXISTING UTILITIES.

4 RELOCATE EXISTING OVERHEAD POWER LINE TO UNDERGROUND.

COORDINATE WITH UTILITY COMPANY - SEE ELECTRICAL

5 INTERMEDIATE COLUMN ON FENCE LINE. REMOVE AND REPLACE

FENCING IN KIND AS NEEDED TO ACCOMMODATE CONSTRUCTION

7 NEW END COLUMN ADJACENT TO FENCE LINE.

REF. NOTES ( ):X

TRUE

NORTH

08222006-0-COVER SHEET
08222006-1-C000
C000
08222006-2-A101-LOCATION 42 EAST
08222006-2-A102-LOCATION 42 WEST
08222006-2-A103-LOCATION 25
08222006-2-A104-LOCATION 46
08222006-2-A105-LOCATION 29
08222006-2-A106-LOCATION 14
08222006-2-A107-LOCATION 18
08222006-2-A108-LOCATION 12
08222006-3-S 01
08222006-3-S101
08222006-3-S102
08222006-7-E101
E101

File details come from the government source that posted it. Updated .