Attachment 4 - DEVTEK_-_BIODIGESTER_DATA_SHEET.pdf

PDF 5 MB Posted

Attached to
SOLICITATION AMENDMENT - 19N15026R0374-0001
Solicitation number
19N15026Q0001
Issued by

About this file

This is a product data sheet for the T16NS1 Range BIODIGESTER, a sewage treatment system designed for up to 16 persons with a daily sewage flow capacity of 2.4 cubic meters. The system is manufactured by Devtek Tanks Limited (Nigeria) and Burnham Environmental Services Limited (United Kingdom).

The T16NS1 features a simple installation process requiring no concrete backfill in dry ground conditions, with provisions for high water table installations using 4 cubic meters of concrete anchor coverage. The system operates quietly with no underground moving parts, minimizing maintenance requirements. The unit measures 2260mm wide by 2260mm long by 2270mm deep, with a standard inlet drain depth of 600mm, and is powered by a single 240V, 90W air blower. The biodigester is designed to produce effluent meeting or exceeding environmental discharge standards with Biochemical Oxygen Demand (BOD5) of 20mg/l, Suspended Solids of 30mg/l, and Ammoniacal Nitrogen (as N) of 20mg/l. The system conforms to all Nigerian "Consent to Discharge" environmental regulations. Optional accessories include sample chambers, pumping systems, high-level alarm beacons with float switches, and remote reporting capabilities via mobile phone technology. Contact information is provided for both the Nigeria office (+234(0)8099333360) and United Kingdom office (+44(0)1278 786104).

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DATA SHEET

T16NS1 Range - up to 16 persons l Simple process

- Quiet operation l Simple installation

- No concrete back fill required in dry ground l Simple maintenance

- No moving parts underground

Installation is simple in areas with a high water table -just cover the anchors with 4m3 concrete.

Why use a

Environmental Regulations

BIODIGESTER conforms to all the normal ‘Consent to Discharge’ environmental requirements of the relevant authorities in Nigeria.

biodiges ter@ devtektanks.c om Tel: +234(0)8099333360

P erformanc e The plant is designed to produce an effluent quality of:

• BOD 5 20mg/l

• Suspended Solids 30mg/l

• Ammoniacal Nitrogen (as N) 20mg/l

More stringent effluent qualities may also be catered for. The effluent can be discharged to a watercourse or via a soakaway, subject to approval.

S ewag e f low/day 2.4m 3

T16NS1 standard inlet drain depth 600mm ref T16NS1

Dimensions: T16NS1 2260 mm wide 2270 mm deep

2260 mm long 600 mm inlet drain depth weight:

Extras available for your

T16NS1 BIODIGESTER

T16NS1 References:

T16NS1 Electrical Ratings:

Air B lowers : 1 a t 2 4 0 v 90 w l SAMPLE CHAMBER When discharging to a soakaway it is a requirement that you install a sample chamber so that the effluent quality can be periodically checked. Available to suit all outlet depths of our standard range.

l PUMP Should you require a method of pumping to or from your BIODIGESTER, we have a range of suitable systems to meet your requirements.

l HIGH LEVEL ALARM If you are relying on a pump to discharge the effluent, it is important to install a warning beacon to alert to failure. This is a flashing beacon with a float switch for installing within the pump chamber.

l REMOTEREPORTING You can be alerted by text to your mobile phone if any problems occur with your unit.

Our new remote reporting system is based on mobile phone technology. Contact us for further details.

Once installed, your BIODIGESTER will be virtually invisible.

biodiges ter@ devtektanks.c om Tel: +234(0)8099333360

MODEL T16NS1 BIODIGESTER

Email: sales@biodigester.co.uk

Nigeria

DEVTEK TANKS LIMITED

Email: biodigester@devtektanks.com

United Kingdom

BURNHARM ENVIRONMENTAL

SERVICES LIMITED

T el : +44( 0) 12 78 78 6 10 4 www.biodigester.co.uk www.devtektanks.com Tel:

+234(0)8033241375

+234(0)8099333360

ACCESS COVER

END SECTION

SIDE SECTION

PLAN

T

COVER

INNER

CHAMBER

100mm

INLET

PIPE

100mm

OUTLET

PIPE

100mm

INLET

PIPE

100mm

OUTLET

PIPE

100mm

INLET

PIPE

100mm

OUTLET

PIPE

File details come from the government source that posted it. Updated .